262 2nd St - Final Survey MAP SHOWING BOUNDARY SURVEY OF
2nd STREET LOT 16 ACCORDING TO THE PLAT OF
(40' R/W) ATLANTEC REACH TERRACE
_ _ _ _ _ AS RECORDED IN PLAT BOOK 15 PAGE 34 OF THE CURRENT
BENCHMARK
APPROXIMATE CENTERLINE PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA.
NAIL & DISK
EDGE OF LB5488
PAVEMENT ELEVATION = 9.83 EDGE OF
(NAVD 1988) PAVEMENT
a J(R) CERTIFIED TO:
CNC •ARON .' e1/2PAVER ° a 314CARL HOLT SMITH
NO. 4144 DRIVE 50 0Q 0.34' NW'LY
1/2" 50.00' (R) IRON P/PE 50.09' 1/2"
IRON PIPE 49.92' (M) IRON PIPE
o
�9s0A 90 00 5
R•
VER PAVER
D IVE DRIVE
!14N. N:
4�GoJc TEPS
ROC OCK
0.1'
10.0' CONC 5.2'
13.0'
y\
FF-10.39
FF-11.83 FF=10.37
11
LOT 6
BLOCK 30
3 STORY
ACN FRAME o
y PAD NO- 262
Q
CONC.
FF=,0.99
mW
9 9'. . . . . . 17.7'
�t
O rii FF=11.79 NQ Z trj
D of 5.2' n n Q
R
0.1'ui
12.0' 5.2'
CONC.
STEP 3
N
4;8' cr
13.5' O
Z FF=(11.46') 2ND FLOOR j
C-4 HOUSE m
1ST FLOOR
cow `� 2
CONC O0 C)
LOT 17 S
m
1 STORY
FRAME
BUILDING C, 17,2'
p o
LOT 5
BLOCK 30
LOT 16
CONC.
STEPS
NOTE:
1.) CONTROL BENCHMARK IS FDOT FPRN STATION "KREG" CRAIG FIELD 30'20'09.73049" N, 81'54.43487" W.
2,) ELEVATIONS ARE SHOWN THUS (9.83') AND ARE IN REFERENCE TO NAVD1988 DATUM.
X-REF: 63036 3,) SITE BENCHMARK WAS ESTABLISHED USING SPECTRA PRECESSION EPOCH 50 GNSS RECEIVER
VINYL 13.6'
SHED FLOOD ZONE"X" - AREAS DETERMINED TO BE OUTSIDE THE 0.2X ANNUAL CHANCE FLOOD PLAIN /FLOOD ZONE "X (SHADED)' AREAS OF 0.2X ANNUAL CHANCE FLOOD; AREAS OF 1X ANNUAL CHANCE HATH AVERAGE DEPTHS OF LESS THAN i
L5.7' FOOT OR WITH DRAINAGE AREAS LESS THAN 1 SQUARE MILE; ANO AREAS PROTECTED BY LEVEES FROM 1X ANNUAL CHANCEFL00D.SHED6' �.9.0o s E Y0.3' OFF51 � R vQ R. ANGLEs ARE SHOWN aN THIS SURVEY,GENERAL NOTES:
2. STRUCTURE N0. 262 SHOWN HEREON UES WITHIN FLOOD ZONE X AS BEST DETERMINED
0.2' FROM F.E.M.A. FLOOD MAPS PANEL NO. 40 A
9 DATED 06/03/2013
O A C Q®^' A T Lam'D SURVEYORS
� 1 R V E Y®R C 'N C. 3. THIS IS A SURFACE SURVEY ONLY. THE EXTENT OF UNDERGROUND FOOTINGS, PIPES AND
V�✓ V /� c �/ ` v UTwTIES. IF ANY, NOT DETERMINED.
0.7' W
LAND d( ENGINEERING SURVEYS 4• nils A1TIONAL AND/OR ENVIRONMENTALLY SENSITIVE AREAS IF ANY, NOT LOCATED BY
3846 BLANDING BOULEVARD 5. THIS SURVEY BASED ON LEGAL DESCRIPTIONS FURNISHED. THE PUBLIC RECORDS WERE
0.4' 1 2" I NOT SEARCHED BY THIS SURVEYOR FOR EASEMENTS, TITLE, COVENANTS, B.R.L.'S
1/2" CAP 49.84' (M) / a JACKSONVILLE, FLORIDA 32210 RESTRICTIONS, CLOSURES, TAKINGS OR ORDINANCES, ETC.
UNREADABLE , IRON PIPE 904-771-6468 6. UNLESS OTHERWISE STATED ALL IRON PIPES FOUND HAVE NO IDENTFICATION,
IRON PIPE 50.00 (R) J 9 LEGEND/AeBREv1
CERTIFICATE OF AUTHORIZATION NO. LB 0005488 AT,ONs
O AC . AIR CONDITIONER PLS PROFESSIONAL LAND SURVEYOR
`S S v BRL BUILDING RESTRICTION LINE PSN . PROFESSIONAL SURVEYOR L MAPPER
BT BUILD NG TIE RR) - RECORD
BTN . BETWEEN
C&R COVENANTS 6 RESTRICTIONS RLS . REGISTERED LAND SURVEYOR
LOT 15 1 HEREBY CERTIFY THIS SURVEY WAS DONE UNDER MY CH CHORD CAN NOT READ RAW . RIGHT OF WAY
LOT 4 DIRECTSUPERVISION AND MEETS THE MINIMUM TECHNICAL CONC CONCRETE o
BLOCK 30 COVD COVERED ' ' ' ' 'SET IRON PPE OR REBAR
STANDARDS FOR LANDS RVEYING PURSUANT TO CHAPTER 5J-17.050 EB ELECTRIC BOX SURV*OR L.B. 5496
THROUG 17.052, FLO A A 1NiST2ATIV CGDE, HAPTER 472 F.S. ET • ELECTRIC TRANSFORMER 6 PAD • ' -FOUND IRON PIPE OR PIN (IP)
' JEA JACKSONVILLE ELECTRIC AUTHORITY 0 • FOUND CONCRETE MONUMENT(CM)
CROSS CUT OR DRILL HOLE ( '
LB = LICENSED BUSINESS �' NAIL&DISC (Nii
BY: --�' LS . LICENSED SURVEYOR -X-X X-X-X-X-X-CHAIN LINK FEN
(M) - MEASURED -I-I-I-I-I-I-I- METAL FENCE
C ARL S B. HATC ER FLORIDA IFICATE NO. 3771 DRB = OFFICIAL RECORDS BOOK - W W -�;; ARE �+CE
NJ
ARLES L. STARLING FLORIDA RTIFICATE NO. 4579 DRV . OFFICIAL RECORDS VOLUME WOOD FENCE
PC . POINT OF CURVE VINYL FENCE
RAYMOND J. SCHAEF FLORIDA CERTIFICATE NO. 6132 PCC . POINT OF COMPOUND CURVE - OVERHEAD UTILITY
PEG = POOL EQUIPMENT PAD FIRE HYDRANT
PI • POINT OF INTERSECTION • ' ' ' ' ' ' ' PHONE RISER
JOB NO. 66142 DATE 02/03/2016 PRC . POINT OF REVERSE CURVE Dm' ' ' ' • • •WATER METER
1 , c 1 D, PRM =PEtiMANf NT A£fEKE NCE MONUMENT
DRAFTER RJS/ECA PT =POINT NE 1ANCENCY 0
SCALE: Un
DIAMETER
,[-. . . . . . . . GUY ANCHOR
NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER
i