331 2nd St 2013 addition CITY OF ATLANTIC BEACH
J 800 SEMINOLE ROAD
j � ATLANTIC BEACH,FL 32233
INSPECTION PHONE LINE 247-5814
jilt
Application Number . . . . . 13-00002403 Date 4/30/13
Property Address . . . . . . 331 2ND ST
Application type description RESIDENTIAL ADDITION
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 49000
-------------------------------------------------------
Application desc
865 SF Addition to rear of dwelling
-----------------------------------------------------
Owner Contractor
-
------------------------
-----------------------
SLUZEVICH AARON OWNER
331 2ND ST
ATLANTIC BEACH FL 322335229
--- Structure Information 000 000 REAR ADDITION 865 SQ FT
Construction Type . . . . . TYPE 5-A
Occupancy Type . . . . . . RESIDENTIAL
Flood Zone . . . . . . . . ZONE X
---------------------------------------------------
Permit . . . . . . RESIDENTIAL ADDITION
Additional desc .
Permit Fee 295 . 00 Plan Check Fee 147 . 50
Issue Date . . . Valuation 49000
Expiration Date . . 10/27/13
--------------------------------------------------
Special Notes and Comments
If on-site storage is required, a post construction
topographic survey documenting proper construction will be
required.
Roll off container company must be on City approved list
and container cannot be placed on City Right-of-Way.
(Approved: Advanced Disposal, Realco, Shappelle ' s and Waste
Management . )
Full erosion control measures must be installed and
approved prior to beginning any earth disturbing
activities . Contact Public Works (247-5834) for Erosion
and Sediment Control Inspection prior to start of
construction.
2010 FLORIDA BUILDING CODE, 2008 NATIONAL ELECTRIC CODE
*REPORT ANY UNFORSEEN STRUCTURAL DAMAGE TO THE BUILDING
DEPARTMENT IMMEDIATELY.
WINDOW AND DOOR INSPECTION:
*INSTALLATION INSTUCTIONS REQUIRED
*ALL STICKERS ARE TO REMAIN ON THE WINDOWS
*PROVIDE ACCESS TO ALL WINDOWS TO INSPECT FASTENERS
PERMIT IS*,& j5'01,N'�WAWU902E G��I'1'I� Y 1 �4�LA� IC�E�C I D THE FLORIDA
BUILDING CODES.
.� CITY OF ATLANTIC BEACH.
I 800 SEMINOLE ROAD
J - ATLANTIC BEACH,FL 32233
INSPECTION PHONE LINE 247-5814
Page 2
Application Number . . . . . 13-00002403 Date 4/30/13
------------------------------------------------------------
Special Notes and Comments
CONTROL COMPANY PRIOR TO C.O.
----------------------------------------------------------
Other Fees . . . . . . . . . STATE DCA SURCHARGE 4 . 43
DEV REVIEW-SINGLE & 2-FAM 50 . 00
ENG REV PRE APP > 3 HRS 25 . 00
STATE DBPR SURCHARGE 4 .43
UTIL REV PRE APP >3 HRS 25 . 00
--------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- -
Permit Fee Total 295 . 00 295 . 00 . 00 . 00
Plan Check Total 147 . 50 147 . 50 . 00 . 00
Other Fee Total 108 . 86 108 . 86 . 00 . 00
Grand Total 551 . 36 551 . 36 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
BUILDING PERMIT APPLICATION
CITY OF ATLANTIC BEACH FILE
�
800 Seminole Road, Atlantic Beach, FL 32233
Office (904) 247-5826 Fax (904) 247-5845
Job Address: J-f a✓J -ST�£�T Permit Number:
Legal Description Parcel#
oor ea o q t• 6(S' non-.Ft
Valuation of Work$ °aO` Proposed Work heated/cooled
Class of Work(circle one): New A ditio Alteration Repair Move Demolition pool/spa window/door
Use of existing/proposed structure(s) (circle one): Commercial R�eso
If an existing structure,is a fire sprinkler system installed? (Circle one): N/A
Florida Product Approval#
For multiple products use product approval form
Describe in detail the type of work to be performed:
Property Owner Information: pC�
�1A&IJ sl,,It we'd ���T is .O
Name: Address:
Ci .4T&�6o ne 6l,4c ll State AZZip 3 Phone Felf Cot - m 904k-
E-Mail or Fax# (Optional) 5Z a
Contractor Information:
Company Name: ���"�"�CQ 's9�f��-Qualifying Agent:
City State Zip
Address:
Office Phone Job Site/Contact Number Fax#
State Certification/Registration#
Architect Name&Phone#
Engineer's Name&Phone#
Fee Simple Title Holder Name and Address
01 Ae;--
Bonding Company Name and Address
Mortgage Lender Name and Address
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the
issuance qt the standards of all laws regulating construction in this jurisdiction.. This permit becomes null
a permit and that all work will be performed to
and work void
o work is commenced commenced within six I understand that separate permits muor st be secuconstrucrion
edfor Electricalor work is suspWork,Plumbing,Sigended or ns,aWells,Pols I urnaces,Boilers,Heaters,
Tanks and Air Conditioners,etc.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS
TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH
YOUR LENDER OR AN ATTORNEY BEFR ENTE RECORDING YOUR NOTICE OF
COMI hereb certify that 1 have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this
type o/Ywork will be complied with whether speci led herein or not. The granting of a permit does not presume to give auth9Kty to violate or cancel the
provisions of any other federal,state, or local law regulating construction or the performance of construction.
Signature of Owner Signature of Contract
Print Name � J Print Name .................................. ...................................................................................................
.....................
.............................
Before ~ Before me 20
this a f 20 13- this Day of
Notary Public Notary Public
� Revised 10.24.12
i
DO NOT WRITE BELOW- OFFICE USE ONLY
Applicable Codes: 2010 FLORIDA BUILDING CODE
Review Result (circle one):
Approved Disapproved Approved w/ Conditions
Review Initials/Date:
Development Size
Habitable Space S S. F, Non-Habitable
Impervious area
Miscellaneous Information
Occupancy Group
Type of Construction
Number of Stories
Zoning District
Max. Occupancy Load
Fire Sprinklers Required
Flood Zone
Conditions/Comments:
' F1IVED
4rt1r City of Atlantic Beach APPLICATION NUMBER
APR Q t 2013
(To be assigned b the Building Department.)
Building Department
800 Seminole Road
4� Atlantic Beach, Florida 322.33-5445,Y: _
Phone(904) 247-5826 Fax(904)241-bb4b
Date routed: �... 1--P13
•.,,.���,����;- E-mail: building-dept@coab.us
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
33 f V T; Department review required Yes No
Property Address:
Building
Applicant: /1 �'�' ��� Planning &Zoning
r Tree Administrator
Project: 1-9-41,11177 0A B�Sr �� Public works
Public Utilities
• Public Safety
Fire Services
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St. Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
I
Reviewing Department First Review: [—]Denied.
(Circle one.) Comments: �Approved.
BUILDING �p
PLANNING &ZONING Reviewed by: Date:
i
TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied.
eV
V
Comments:
Reviewed by: Date:
FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied.
Comments:
I Reviewed by: Date: I
Revised 07/27/70
,t-<ECEIVED
City of Atlantic Beach APR O 2 2013 APPLICATION NUMBER
�a Building Department (To be assigned by the Building Department.)
a'
800 Seminole Road BY: /5 —
Atlantic Beach, Florida 32233-5445
Phone(904) 247-5826 • Fax(904)247-5845 .- �---�3
. Date routed:
E-mail: building-dept@coab.us
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: 331 C>? — m �: Department review required Yes No
Building
fv Applicant: /� �<� Planning &Zoning
+// Tree Administrator
Project: AZlyI 776 AJ eaS Public Works
Public Utilities
Public Safety
Fire Services
Review fee $_ Dept Signature 4
Receipt
Other Agency Review or Permit Required Review or Dateof Permit Verified By
Florida Dept. of Environmental Protection
Florida Dept. of Transportation _
St. Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: ❑Approved. Denied.
(Circle one.) Comments: Gam!-c9C�
BUILDING
PLANNING &ZONING Reviewed by: Date: y
TREE ADMIN. Second Review: ❑Approved as revised. Denied.
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:--I -�
FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied.
Comments:
Reviewed by: Date: jz�
Revised 07/27/10
iya,1;�J, City of Atlantic Beach APPLICATION NUMBER
;> Building Department (To be assigned by the Building Department.)
1 ? 800 Seminole Road
Atlantic Beach, Florida 32233-5445
1J Phone(904)247-5826 - Fax(904)247-58451-13
e,;` s31ar E-mail: building
-dept@coab.us 1 11
Date routed: ��
City web-site: http://vvww.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: � Department review required Yes No
ov Building
Applicant: J` Planning &Zoning
Tree Administrator
Project: 1-9-j" 1111 770 IV 5� �� Public Works
Public Utilities
Public Safety
Fire Services
Review fee $ L" Dept"- mature *..
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St. Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: ❑Approved. XDenied.
(Circle one.) Comments:
BUILDING j
CANNING&ZONING — – Rev' wed by: C? Date:
TREE ADMIN. Second Review: Approved as revised. ❑Denied.
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
6�a �
FIRE SERVICES Third Review: 0-Approved as revised. []Denied.
Comments:
Reviewed by: Date:
Revised 07/27/10
City of Atlantic Beach APPLICATION NUMBER
To be assigned b the Building Department.)
Building Department ( 9 Y 9
800 Seminole Road
Atlantic Beach, Florida 32233-5445 /3
Phone(904) 247-5826 Fax(904)247-5845 _
E-mail: building-dept@coab.us
Date routed:
City web-site: http://vmw.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address:
3-31 & Department review required Yes No
/�e � Building
Applicant: At"/qC t� Planning &Zoning
Tree Administrator
Project: 1T14W1111 TToxJ gas �T Public Works
Public Utilities
Public Safety
Fire Services
Review fee $ Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St. Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: P<pproved. ❑Denied.
(Circle one.) Comments:
BUILDING—
PLANNING &ZONING Reviewed by: Date: 7
TREE ADMIN.
Second Review: ❑Approved as revised. FIDXd.
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied.
Comments:
Reviewed by: Date:
Revised 07/27/10
CITY OF ATLANTIC BEACH
FILE COPY
1. FLORIDA STATUTES; CHAPTER 489, FLORIDA STATUTES, PART 1N�T�C�TION
CONTRACTING"REQUIRES OWNER/BUILDER TO ACKNOWLEDGE THE LAW: ' r� fill 1 2013
14
DISCLOSURE STATEMENT FOR SECTION 489.103(7),FLORIDA STATUTES: By
STATE LAW REQUIRES CONSTRUCTION TO BE DONE BY LICENSED
CONTRACTORS. YOU HAVE APPLIED FOR A PERMIT UNDER AN EXEMPTION TO THAT
LAW. THE EXEMPTION ALLOWS YOU,AS THE OWNER OF YOUR PROPERTY.TO ACT AS
YOUR OWN CONTRACTOR EVEN THOUGH YOU DO NOT HAVE A LICENSE. YOU MUST
SUPERVISE THE CONSTRUCTION YOURSELF. YOU MAY BUILD OR IMPROVE A ONE-OR
TWO FAMILY RESIDENCE OR A FARM OUTBUILDING. YOU MAY ALSO BUILD OR
IMPROVE A COMMERCIAL BUILDING AT A COST OF$25.000.00 OR LESS. THE BUILDING
MUST BE FOR YOUR USE AND OCCUPANCY. IT MAY NOT BE BUILT FOR SALE OR LEASE.
IF YOU SELL OR LEASE A BUILDING YOU HAVE BUILT YOURSELF WITHIN ONE YEAR
AFTER THE CONSTRUCTION IS COMPLETE, THE LAW WILL PRESUME THAT YOU BUILT
IT FOR SALE OR LEASE. WHICH IS IN VIOLATION OF THIS EXEMPTION. YOU MAY NOT
HIRE AN UNLICENSED PERSON AS YOUR CONTRACTOR YOUR CONSTRUCTION MUST
BE DONE ACCORDING TO THE BUILDING CODES AND ZONING REGULATIONS. IT IS
YOUR RESPONSIBILITY TO MAKE SURE THAT PEOPLE EMPLOYED BY YOU HAVE
LICENSES REQUIRED BY STATE LAW AND BY COUNTY OR MUNICIPAL LICENSING
ORDINANCES.
II. INJURY LIABILITY; SINCE OWNERS MAY BE LIABLE FOR INJURIES TO WORKERS THEY HIRE,
THE BUILDING DEPARTMENT SUGGESTS WORKER'S COMPENSATION INSURANCE BE
PURCHASED.
111. IRS WITHHOLDING; OWNERS HIRING WORKERS BECOME EMPLOYERS AND SHOULD ALSO
OBSERVE IRS WITHHOLDING TAX AND/OR FORM 1099 REQUIREMENTS ON THE WORKERS THEY
EMPLOY ON THEIR IMPROVEMENT TRADES.
IV. PENALTY; UNLICENSED CONTRACTORS CANNOT BE EMPLOYED UNDER ANY
CIRCUMSTANCES. OWNERS BEING SUBJECT TO $5,000 PENALTY UNDER FLORIDA STATUTE NO.
455-228(1). AN"OCCUPATIONAL LICENSE" IS NOT ADEQUATE. THE OWNER SHOULD PHYSICALLY
SEE THE COUNTY "CERTIFICATE OF COMPETENCY" OR THE FLORIDA "CONTRACTORS
CERTIFICATE" TO ASCERTAIN IF A PERSON IS A LICENSED CONTRACTOR. TELEPHONE THE
BUILDING DEPARTMENT(247-5826)IF IN DOUBT.
V.ACKNOWLEDGEMENT; I HEREBY ACKNOWLEDGE THAT I HAVE READ THE ABOVE DISCLOSURE
STATEMENT AND THAT I COMPLY WITH ALL THE REQUIREMENTS FOR THE ISSUANCE OF AN
OWNER-BUILDER PERMIT.
3Z=3-7 9z- D90z
ADDRESS PHONE NUMBER
AAO"
PRINT NAME
SIGNATURE DATE
Before me this_L!day jare
26!n the county of
Duval,State of Florida,has peared herin by himself/herself and affirms that
all statements and declarationd accurate. )t'' DEBORAH AMANDA WHITEoun of • :gig MY COMMISSION#EE 057349
Notary Public at Large,State tY $r Qr%
EXPIRES:May 21,2015
Rf. Bonded Thru Notary Public Underwriters
❑Personally Known
Produced Identification- 72n
Notary Signature ��
F:/BLDG/0-Builder Affadavit REVISED: 4/16/2009
RPR-1-2013 12:35 FROM:CLERK OF COURTS 904 270 1512 TO:924 Iaq_F2._., .hr
�� FILE a
NOTICE OF COMMENCEMENT t
{rTzi EPaREIRDUPuCATE)
M•.iFVR a��.TT��
_ 5
Permit No. 3 d y03 Tax FOHO NO.
State of -- County of ! Q
To whom It may ecmc9rn:
The undorslgned hereby informs you that improvomants wilt bre made to Certain raal property,and In
accordencc with SecVcm 7`13 of the Florida Statutes,tho following Information is stated In this NOTICE OF
COMMENCEMENT. `` t
Legal d03Cfi0oit of property beittg improved:
A'5 All
Address of proparty being improve: 3 r '2�4 5 � r rw re 3Z z --
CTaneral dciscfiption of improvements:
Owner /fir1 /" S L IC-V,
Address '33/ ZAe Icil i4le :o %i;,z
Owner's lnt>mst in site of the Improvement
Fee Simple Titlehotdar(if otlisr than owner)
Name
Address
Dorf rgc1or
Address
Phone No. Sax No_ __--
Surety Qf any) - - -
Addreas^ _ Amount of bond
Phone Wo. Fax No_
Name and address of any person making a loan far the constructlon of the improvements_
Nama
Address
Phone No, Fax No.
Name of parson within the State of Florida,other than himself,designated By owner upon whom notices of ether
documents may be served=
Name
Addrm
Phone No. Fax No_
In addition to himself.Sumer desionates fhe fol swing parsan to rpe�.-.ive a cnpy of the 1_1ennrk NntlrP a¢prnvtried In
Section 793.06(2)(b),Flaltda Statutes.(Fill in at Owner's option)_
Nerr10
Address
Phone NO_ 1=ax No.
Expiration data of Notice trf Commencement(the expiration date Is one(1)year ftam the date of racy ding unlasa a
different date Is specified): A
THIS SPACE FOR RECORDER'S USE ONLY OWNER
Bfpned: DATE
Before ma Hit: L day of 's In iha
C11-
6pa Dtnml $fatr.ofR , hes raon,^yap oa d y
H . La P_.t/l��K nerals by
hlmacff7 aM ft than A s atart:enta and aeclaram"_lie ren p I
- are trio and accurate
v3 }
Doc J.',101 30BO407.OR.EK 15310 Page 2186,
Number Puget:1
Reuordod 04/0112613 at 01:08 PIA ao, utft eWLampe, , c.",of �.-
P.onnin Fussell CLERK CIRCUIT COUPT DUVAL Mymmme?efcnexpree:�
COUNTY t S,monetN Knows or
Produced Ideritificaiiad
,RE.COOR,QING$10.00
i
PLOT PLAN PjYj
LOT 8, EXCEPT THE SOUTH 10 FEET, BLOCK 4, SUBDIVISION "A" ATLANTIC BEACH AS R i
PLAT BOOK 5, PAGE 69 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY,
I I1
1
LOT 5
I LOT T
�i
Ii
LOT 9 I -
1 1 2�IR�OZN _
I ( 50.00' FIELD ) i PIPE./�-_---
1/27 IRON 50.00 0 0.5' (150.00')
PIPE. CM 00.9 5'CIWN UNK FENCE
i' 3gs,
1
I
I �
IN LOT 8
r IIIx 7.000 SO. F(•TOTAL
VIOUS
Cl AREA
A � 3,523 SO. FT.IMPER
` COVERAGE
5O
O s.7 m
1
I
PROPOSED
bL ADDITION
A/C
PAD
O
A I LOT 6
2e3 P 11
10 P •our
LOT '0 o.z' 5.4 I >
0
o
o " >
1-STORY BLOCK x 0 6 N
RESIDENCE No.331 -4
�•GNAW UNK FENCE
5.7 1 5•W000 FENCE 0 I O 0
ICK PA R
j
I I�R5 O
0' X £
V, I
5000 O°d� ,5°=°'0' FIELD 0
ry
1 �. --
h 50.06' FIELD ) ��2"IRON
00j ( %TL, --
__ 10 FEET c __ --- G
--
FO N,CAP o
SOUTH
8 -_
PIPE, o __ -- LINE PER PIAT fel
NORTH RIGHT OF WAY E E
S E C 0 N. RD T OF WAY (PAVED)
NOTES
THIS IS A BOUNDARY SURVEY. 1p zp 40
ANGLES AS PER FIELD SURVEY. Q
NO BUILDING RESTRICTION LINES PER PLAT. SCALE: 1" = 20'
NORTH IS APPROXIMATE.
THE PROPERTY SHOWN HEREON APPEARS TO
LIE IN FLOOD ZONE "X" (AREA OUTSIDE 500
YEAR FLOOD PLAIN) AS WELL AS CAN BE
DETERMINED FROM THE FLOOD INSURANCE
RATE MAP COMMUNITY PANEL No. 120075
0001 D, REVISED APRIL 17, 1989 FOR THE
CITY OF ATLANTIC BEACH, DUVAL COUNTY,
FLORIDA.
"NOT VALID WITHOUT THE SIGNATURE AND DONN W. BOATWRIGHT, P.S.M.
THE ORIGINAL RAISED SEAL OF A FLORIDA BOUNDARY SURVEY RECHECK - FLORIDA LIC. SURVEYOR and MAPPER No. LS 3295
LICENSED SURVEYOR AND MAPPER." MARCH 8, 2013 FLORIDA LIC. SURVEYING k MAPPING BUSINESS No. LB 3672
CHECKED 6Y: BOATMIGHT LAND SURVEYORS, INC. oATE:
DRAWN BY: SWC MAY 16, 2000
FILE: 2013-0164 1500 ROBERTS DRIVE, JACKSONVILLE BEACH, FLORIDA 241-8550 SHEET 1 OF 1
Y000-0354
ILE COPY
rYs-;xwaw-
PO#: K. rwN.�.vvn x ar
Job Name:SOULZEVICH
F
-1
Job Address:
Quote# 2823266
Ship Date:03/21/2013
Sales Person:Tom Frederickson
RPM LUMBER
ShipTo: RPM WOOD PRODUCTS INC Customer LEXSIENA GROUP
Account#:011307-1 Account#
86289 PAGES DAIRY ROAD
YULEE,FL 32097
Phone#(904)225-5633 Fax#(904)225-0888 Phone# Fax#
Line# Item Description Quantity Line Pricing
1.1 DH460 VINYL DH 460 Ordered:3 Sell Price Ext Price
$366.80 $1,100.40
Configuration:3052 IF W/LEH IG G 111 D1 Location:MASTER,BEDROOM
Size:35.50W x 61.50H(size code:3052) Configuration:Equal Lite
Nominal size code:3052 Frame color:White
Frame type:Integral Fin Outboard color.PPG SolarBan 60 LowE
Inboard color Clear Glass type:7/8"IG(1/8 Ann-518 air-1/8 Ann)
Argon gas:Yes Colonial style:No Colonial
What kind:Sweep Latch How many locks:Two Locks
e. Screen type:18x16 Charcoal Outboard Top:PPG SolarBan 60 LowE
Inboard Top:Clear Outboard Bottom:PPG SolarBan 60 LowE
Inboard Bottom:Clear Top:7/8"IG(1/8 Ann-5/8 air-1/8 Ann)
Bottom:7/8"IG(1/8 Ann-5/8 air-1/8 Ann) Calculated+:50.00
Calculated-:50.00 Certification#:190-799
Actual DLO width::35.50 Actual DLO height::61.50
Custom Size DLO Width:0 Custom Size DLO Height:0
Full or Half Screen:Full Screen Label:Ll-Factor 0.31
Label:SHGC:0.28 Label:VT:0.52
COG:VT(use for Turtle Code):0.72 Energy Star.SC,NC
2.1 DH460 VINYL DH 460 Ordered:2 Sell Price Ext Price
$500.25 $1,000.50
Configuration:4040 IF W/LEHOTIG G 1/1 D1 Location:MASTER BATH
Size:47-50W x 47.50H(size code:4040) Configuration:Equal Lite
Nominal size code:4040 Frame color:White
Frame type:Integral Fin Outboard color:PPG SolarBan 60 LowE
Inboard color Obscure Glass type:7/8"IG(1/8 Tmp-5/8 air-1/8 Tmp)
Argon gas:Yes Colonial style:No Colonial
What kind:Sweep Latch How many locks:Two Locks
Screen type:18x16 Charcoal Outboard Top:PPG SolarBan 60 LowE
Inboard Top:Obscure Outboard Bottom:PPG SolarBan 60 LowE
Inboard Bottom:Obscure Top:7/8"IG(1/8 Tmp-518 air-1/8 Tmp)
Bottom:7/8"IG(1/8 Tmp-5/8 air-118 Tmp) Calculated+:50.00
Calculated-:50.00 Certification#:190-799
Actual DLO width::47.50 Actual DLO height::47.50
Custom Size DLO Width:0 Custom Size DLO Height:0
Full.or Half Screen:Full Screen Label:U-Factor 0.31
Label:SHGC:028 Label:VT:0.52
COG:VT(use for Turtle Code):0.72 Energy Star:SC,NC
Quote# 2823266
Print Date 3/5/2013
Page 1 of 2
t
i
k �
f
0
t.� b 0 a
x � n, 0 ,o �9
c --• o .�„ J i
w �
a
O °' o
n.
A
�} F
a)
O a c.,
> Nj I� % -n - = C
o a •°� � : A cn '� � ap c
Ln o b o
CZ
IS
o 3 o 3 Q
cn cn V, Q O cn T U Q [T. Q Q
C' Q W N ri vi N ri -,T Ln
U U R
61 Y 7
s.,
)
�
4 �
\ �
2
\ �
j
.. . �
. �
\ v
% 3 �
\ �
%
$ •
§ w
§ $
a �
;
§
#
� 3
�
% z k § � a � ¢ ,g u o 2 / � q u \ � � •
{ § 7
> / c"'.
/ \ tic= e / �
m e = s e s
��
5 ¢ 5 \ @ o \ g 2 ( ) a y e ®
R 9 2 ?
c £ \ \ m Q 2 \ y 3 2 3 m o 4 » ¥ K = 2 2 & a & ¥ y 2 U « m
a 6 6 Q ¢ Q w « « w £ G a 6 a w w « « »
_ � \ _ _ /
u ,
w
w
0
C
O
it
C7
O
tl
Q
u
o Q
"CCIO
N M V'1
GQ
Y•� a�
O
� 0 N
�a
a y o
C
y
4O O M
V1 . y
wN J 1
J
0 0
a K
G J tb
C:
o 0 y
C. G, ro T3
A � o
J J �
orn Ilk
o
_ N
> 40
o ¢ 2
o.� n. a %,
Q
F" o o z
o � y
w go 43 o ¢ r- r.
.s °°
v ;� J n. o. a
N _
w @ O U Sn O y N
U
�00'
_ i.
�� i
>yl� hoft° Project Summary t: Job:
9 FILE COPY � Date: 4/8/2013
Entire House By: CRAIG EDDY
ONE HOUR AIR .,.:e �►.,,� .R,.w: y, ..�.
1198 MAYPORT RD#1.ATLANTIC BEACH,FL 32233 Phone:904-241-3107 Fax:904247-5528 Lkensa:CAC1814420
Project • •
For: AARON SLUZEVICH
331 2ND ST,ATLANTIC BEACH, FL 32233
Phone:904-
Notes:
Desiqn Information
Weather: Jacksonville/Craig, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 35 'F Outside db 91 of
Inside db 70 'F Inside db 75 'F
Design TD 35 'F Design TD 16 'F
Daily range M
Relative humidity 50 %
Moisture difference 53 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 15187 Btuh Structure 12062 Btuh
Ducts 0 Btuh Ducts 0 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 15187 Btuh Use manufacturer's data y
Rate/swing multiplier 1,00
Infiltration Equipment sensible load 12062 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 2171 Btuh
Ducts 0 Btuh
Heating Cooling Central vent(0 cfm) 0 Btuh
Area(ftp 896 896 Equipment latent load 2171 Btuh
Volume(ftp 7168 7168
Air changes/hour 0.61 0.32 Equipment total load 14233 Btuh
Equiv.AVF(cfm) 73 38 Req.total capacity at 0.74 SHR 1.4 ton
Heating Equipment Summary Cooling Equipment Summary
Make GOODMAN Make GOODMAN
Trade AMANA DISTINCTIONS Trade AMANA DISTINCTIONS
Model GSZ130181 Cond GSZ130181
AHRI ref 5358269 Coil ARUF18
AHRI ref 5358269 {
Efficiency 0 HSPF Efficiency 15 SEER ;
Heating Input Sensible cooling 12893 Btuh 11
Heating output 0 Btuh @ 47-F Latent cooling 4507 Btuh
Temperature rise 0 'F Total cooling 17400 Btuh
Actual air flow 0 cfm Actual air flow 549 cfm
Air flow factor 0 cfm/Btuh Air flow factor 0.046 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.85
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. !
2013-Apr-0811:46.00
WII hf ofC•
Right-Suite®universal 2012 12.1.06 Right J®Mobile Page 1
...lwstmplacle443B-a9ef-4d7a-ab59.44c585c534b8.rup Calc=MJ8 FrontDoorfaces: S
i
PLOT PLAN
LOT 8, EXCEPT THE SOUTH 10 FEET, BLOCK 4, SUBDIVISION "A" ATLANTIC BEACH AS RECORDED IN
PLAT BOOK 5, PAGE 69 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA,
141AA 4,),) :5/06, LOT _
," ///t"//�, LOT FILE COPY P
T 7
' I LO �
_ dl �,�.q,yp.*,+n}gap..r+k.rp�n,,,rwnia !g"m,
�1 n")�O. LOT 9
J `� 'I ( 50 Op' FIELD) itEt
_nf 1/V,)s 50.00 -- -
/1�'rllllwD t/z' ' 0.3' 150.00)
E,No CM y'C/WN UNK FENCE
1
i
LOT 8
x m F7.TOTAL LOT AREA
( (C 73 52,000 SO.3 SO, FT.IMPERVIOUS AREA
5.7 ms 50% COVERAGE
0.4' PROPOSED is
ADDITION
O PAD
S O
A LOT 6
LOT 10 a-P• 5 7 a •art l
Il,O .41
6 0 �o Q '1
Q o r�
7
—STORY BLOCK O m
N
RESIDENCE No'331 Y O 6 D7 -4
�.C"J U4K Fc
5.7
O
N
-4
G��F i�� ,( mss. FVEIO ��
`LS 0 0.00FIE J `'i 115 0_1
FlEL ) o vwao,io WON
p
UT 10 FE
PIPE•
oo _- g
PER PLAT (*1
- NOR1H
GHT OF WAY LINE
--------"- S T R E E T
S E C N
40'
MG
F WAY (PAVED)
NOTES
THIS 15 A BOUNDARY SURVEY.
ANGLES AS PER FIELD SURVEY. J Q 10 20 411No AAl
NORTH 1 IS APPROIMNG IATE.N LINES PER PIAT. y✓�G SCALE: 1" = 20'
ItM L
THE PROPERTY SHOWN HEREON APPEARS TO L 1��0 C ��f� 7"
LIE IN FLOOD ZONE "X (AREA OUTSIDE 500 ��/` Z S"/_f
YEAR FLOOD PLAIN)AS WELL AS CAN BE )
DETERMINED FROM THE FLOOD INSURANCE
RATE MAP COMMUNITY PANEL No. 120075
0001 0, REVISED APRIL 17, 1989 FOR THE
CITY OF ATLANTIC BEACH, DUVAL COUNTY,
FLORIDA.
"NOT VALID WITHOUT THE SIGNATURE AND DONN W. BOATWRIGHT, P.S.M.
THE ORIGINAL RAISED SEAL OF A FLORIDA BOUNDARY SURVEY RECHECK - FLORIDA LIC. SURVEYOR and MAPPER No. LS 3295
LICENSED SURVEYOR AND MAPPER.` MARCH 8, 2013 FLORIDA LIC. SURVEYING h MAPPING BUSINESS No. LB 3672
CHECKED 9Y: BOATWRIGHT LAND SURVEYORS INC. °A�`
DRAWN BY. SWCMAr 15,
s z000
FILE, 2013-0164 1500 ROBERTS DRIVE, JACKSONVILLE BEACH, FLORIDA 241-8550 SHEET i OF I
2000-0354
® Lumber design values are in accordance with ANSI/TPI 1-2007 section 6.3
These truss designs rely on lumber values established by others.
MiTek®
RE: 130517 - RPM 2ND STREET RENOVATION MiTek USA, Inc.
Site Information: 6904 Parke East Blvd.
Customer Info: RPM Lumber Project Name: 2nd Street Renovation Model: Tampa,FL 33610-4115
Lot/Block: Subdivision:
Address: 331 2nd Street
City: Atlantic Beach State: FL
Name Address and License#of Structural Engineer of Record, If there is one, for the building.
Name: License#:
Address:
t
City: State:
General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special
Loading Conditions):
Design Code: FRC2010/TPI2007 Design Program: MiTek 20/20 7.3 �
Wind Code: ASCE 7-10 Wind Speed: 130 mph Floor Load: N/A psf
Roof Load: 32.0 psf am
NWANO
This package includes 9 individual, dated Truss Design Drawings and 0 Additional Drawings. 1.+1 M
With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules.
No. Seal# Truss Name Date
1 T4765987 A01 3/19/013
12 I T4765988 I A02 13/19/0131
W C)
13 I T4765989 I A03 13/19/0131 ,'t joB#
14 IT4765990 IA04 13/19/013 Rewlewed
15 I T4765991 I A05 13/19/013 No exceptions ❑4 Rejected x h
Reviewed
�3/19/013 � � 2 Exceptions Noted Cl5 information („) � Z
16 IT4765992 IJ02 O �
[7 I T4765993 I J04 13/19/013 ®$ Revise&Resubmit ony ' Z
18 I T4765994 I J07 13/19/013 Rc,= 's, a,y ra Q=cawomwx.wpm ma wood rows^- - � Q
�9 T4765995 JC09 3/19/013 t°0e°"'n°e d 1or win tw wtoct
review does not releve da Cantrector tran rospdrxlbllM. - U w A O A
de6gns to wNch the oontreao N reepouDb for cart..y.
of trw CoMW Doane te,"to tM eds end W Q V
Tric renew does not oo dkw the mems, r ¢ Q
operetons of the oonatrucOOn. or ssds! O C
-- �
Neretnr,
Cates
Check-_
S; nature: w
A G�
C
The truss drawing(s)referenced above have been prepared by MiTek U
Industries, Inc. under my direct supervision based on the parameters `���OPO\J I N
provided by TrussMart Bldg Compts, LLC. `�.` �.,.��G E N
Truss Design Engineer's Name: Velez, Joaquin g 1
My license renewal date for the state of Florida is February 28,2015.
NOTE:The seal on these drawings indicate acceptance of = 9 :x
professional engineering responsibility solely for the truss -:0 :.• STATE OF :�41J
components shown. The suitability and use of this component Al Q?:•'���:
for any particular building is the responsibility of the building R �•
designer, per ANSI/TPI-1 Sec. 2. ���� NA;
FL Cert. 6634
March 19,2013
Velez,Joaquin 1 of 1
® Lumber design values are in accordance with ANSI[TPI 1-2007 section 6.3
These truss designs rely on lumber values established by others.
MiTek 10
RE: 130517 - RPM 2ND STREET RENOVATION MiTek USA, Inc.
Site Information: 6904 Parke East Blvd.
Customer Info: RPM Lumber Project Name: 2nd Street Renovation Model: Tampa,FL 33610-4115
Lot/Block: Subdivision:
Address: 331 2nd Street
City: Atlantic Beach State: FL
Name Address and License#of Structural Engineer of Record, If there is one, for the building.
Name: License#:
Address:
City: State:
General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special
Loading Conditions):
Design Code: FRC2010/TP12007 Design Program: MiTek 20/20 7.3
Wind Code: ASCE 7-10 Wind Speed: 130 mph Floor Load: N/A psf
Roof Load: 32.0 psf
This package includes 9 individual, dated Truss Design Drawings and 0 Additional Drawings.
With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules.
No. tSea[_#_ Truss Name Date
I1 T4765987 }A01 3/19/013
2 I T4765988 I A02 13/19/013 I
13 I T4765989 I A03 _ 13/19/013 1 SUBMISSION# SOB# - —
14 I T4765990 I A04 13/19/013 1
15 I T4765991 I A05 eview
13/19/013 I � No exce tions 114 Rejected
16 I T4765992 I J02 Reviewed
13/19/013 � ❑2 Exceptions Noted ❑ 5 Onn y"8n°n
I7 I T4765993 I J04 13/19/013 1 1:13 Revise&Resubmit
I8 I T4765994 I J07 13/19/0131 PWe%%d ony hr gena„Mftr anon wBh m.f>�„arsrtw,o tier.-m
19 1 T4765995 JC09 13/19/013 I co"o-s"° mmennts arw to°""�,">�"*''"'a propct design c—"
ratilew dM nct retieva 7a Corgacror from ith thslpm for esign
coigns for which Vw conframw is raeoonslWa to IXN71D1'3r"'-f�...,alp_-_
of fhe Umact°ocumem.
Ns we aw does not ca•.:
oporooru M „.a nr7x
there., _
Date:_.S ,Z-7 I L 7
Chocked By:
Si nature:
The truss drawing(s)referenced above have been prepared by MiTek ������ #fill �
Industries, Inc. under my direct supervision based on the parameters ��oPQ`•'INVFX i,�
provided by TrussMart Bldg Compts, LLC. �G`� �•.•� E N 3�•.? '��
Truss Design Engineer's Name: Velez, Joaquin1"--68182
My license renewal date for the state of Florida is February 28, 2015. = *:• ••'
NOTE:The seal on these drawings indicate acceptance of :'o :jZ
professional engineering responsibility solely for the truss :•• STATE OF :IIJ
components shown. The suitability and use of this component ; T •.'c P.•'� .`
for any particular building is the responsibility of the building �'�;�S• R 1•�•••�\���
designer, per ANSI/TPI-1 Sec. 2. ;I/S,ONA;"'—'
FL Cert. 6634
March 19,2013
Velez,Joaquin I of 1
® Lumber design values are in accordance with ANSI/TPI 1-2007 section 6.3
These truss designs rely on lumber values established by others.
MiTek®
RE: 130517 - RPM 2ND STREET RENOVATION MiTek USA, Inc.
Site Information: 6904 Parke East Blvd.
Customer Info: RPM Lumber Project Name: 2nd Street Renovation Model: Tampa,FL 33610-1115
Lot/Block: Subdivision:
Address: 331 2nd Street
City: Atlantic Beach State: FL
Name Address and License#of Structural Engineer of Record, If there is one, for the building.
Name: License#:
Address:
City: State:
General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special
Loading Conditions):
Design Code: FRC2010/TP12007 Design Program: MiTek 20/20 7.3
Wind Code: ASCE 7-10 Wind Speed: 130 mph Floor Load: N/A psf
Roof Load: 32.0 psf
This package includes 9 individual, dated Truss Design Drawings and 0 Additional Drawings.
With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules.
No. Seal# Truss Name Date
11 JT4765987. IA013/19/013
12 I T4765988 I A02 13/19/013
13 IT4765989 IA03 13/19/0131 SUBMISSIONAE SOB# --
14 IT4765990 �A04 13/19/0131
15 IT4765991 A05 13/19/013 11 Noexce tions ❑4 Rejected
16 I T4765992 I J02 13/19/013 1 ❑2 Reviewed
Exceptions Noted ❑ cJ lntormation
17 I T4765993 I J04 .13/19/0131 only
❑3 Revise 8 Resubmit
8 T4765994 J07 13/19/013 A�o„y,�>
19 I T4765995 I JC09 13/19/013 1 r�Dxur ne fo,orww w�,th tfb wo11 whdCabd in
revlaw door mot resew me Contractor horn responslbgUy,for rraa p omauons in
This
daeatgns to D ru ooraracbr is responsj*tot coma ana w'In d
C«xract Wwments,and for ete safe"I rqurwmer•
i!tla reNaw duan rot consider Ms means. B�s5 of ew wor
opnraticns c .t:`' ,"Werxaes,Ar-
01
dteretq -.: rty of W programs lnad+..
E CONSMIK INC.
Choc};..
"s! nature:
The truss drawing(s)referenced above have been prepared by MiTek
Industries, Inc. under my direct supervision based on the parameters %�OP,Qv�N.,VF� .,
provided by TrussMart Bldg Compts, LLC. `� �•,•��G E N SF•,•��'��
Truss Design Engineer's Name: Velez, Joaquin 8182
My license renewal date for the state of Florida is February 28, 2015. = *:• ••'
= yt
NOTE:The seal on these drawings indicate acceptance of
professional engineering responsibility solely for the truss ..0�.. STATE OF .: 44J
components shown. The suitability and use of this component ; T'•.'c P.•
for any particular building is the responsibility of the building �'�;\S • R �•�'•
designer, per ANSI/TPI-1 Sec. 2. �,��S;ONA;
FL Cert. 6634
March 19,2013
Velez,Joaquin 1 of 1
Lumber design values are in accordance with ANSI/TPI 1-2007 section 6.3
These truss designs rely on lumber values established by others.
MiTek 1
RE: 130517- RPM 2ND STREET RENOVATION
MiTek USA, Inc.
Site Information: 6904 Parke East Blvd.
Customer Info: RPM Lumber Project Name: 2nd Street Renovation Model: Tampa,FL 336104115
Lot/Block: Subdivision:
Address: 331 2nd Street
City: Atlantic Beach State: FL
Name Address and License#of Structural Engineer of Record, If there is one,for the building.
Name: License#:
Address:
City: State:
General Truss Engineering Criteria &Design Loads(Individual Truss Design Drawings Show Special
Loading Conditions):
Design Code: FRC2010/TP12007 Design Program: MiTek 20/20 7.3
Wind Code: ASCE 7-10 Wind Speed: 130 mph Floor Load: N/A psf
Roof Load: 32.0 psf
This package includes 9 individual, dated Truss Design Drawings and 0 Additional Drawings.
With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules.
No. Seal# Truss Name Date
1 T4765987 A01 3/19/013
�2 T4765988 A02 3/19/013
�3 T4765989 A03 3/19/013
�4 f T4765990 A04 13/19/013
5 T4765991 A05 13/19/0131
�6 T4765992 J02 3/19/013
7 T4765993 I J04 13/19/013 1
�8 I T4765994 I J07 13/19/013
�9 I T4765995 I JC09 13/19/0131
The truss drawing(s)referenced above have been prepared by MiTek 01111111111i1
Industries, Inc. under my direct supervision based on the parameters �.%% QV I N VF,--4 i
provided by TrussMart Bldg Compts,LLC. ` OP•' �F '
Truss Design Engineer's Name: Velez, Joaquin 8182
My license renewal date for the state of Florida is February 28,2015.
v
NOTE:The seal on these drawings indicate acceptance of =-o :
professional engineering responsibility solely for the truss STATE OF : tv:
components shown. The suitability and use of this component ;OT
'•.A-
for any particular building is the responsibility of the building �'.,�s L 0......
�''•C?\�`�
designer, per ANSI/TPI-1 Sec. 2. ����5Ir'ONA
FL Cert. 6634
March 19,2013
Velez,Joaquin 1 of 1
lob TNS Truss Type
Qty Ply RPM 2ND STREET RENOVATION
IW517 A01 Common Truss 2 1 T4765987
TRUSSMART BUILDING COMPONENTS, Midway,GA,31320
7.350 s Sep 26 2012 MiTek Industries,Inc. Tue Mar 19 08:46:39 2013 Page.
4-1113 9-8-31448 ID:TzRDcdmDnGQMIVM86G4k1ZygAC9-0YvjjbiZORsMZ8NpSWNgh3iKMidF3ZB6EkDGmzZRFF
45-5 48 5 4S5 23 9 3 28-9-0 3111-0
4$5 4-11-13 1-4-0
Scale=1:50.9
1.00 12
3x4- 04=
3x4=
3x6= 3x6= 2x8 zz 5 17 6 18 7
3 4 16 2x8= 3x6=
1 2 15 198 9 3x6=
201 11
3x4 11
4x12= t4 13 3x4=
3x6= 6x6 MT20H- 12 4x12 =
3x6=
PlateOffsetsX —&2-41- 10: 0-2-4 12:0 0-12 0-1 14' 1 0 -8 7-0-8
LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) Vclefi L/d
TCLL 20.0 Plates Increase 1.25 TC 0.46 Vert(LL) 0.89 13 >387 240 PLATES GRIP
MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BC 0.56 Vert(TL) -1.51 12-13 >229 180 MT20H 187/143
BCLL 0.0 Rep Stress Ina YES WB 0.47 Horz(TL) 0.21 10 n/a n/a
BCDL 5.0 Code FRC2010/TPI2007 (Matrix)
_
LUMBER Weight:133 Ib FT=0%
-
TOP CHORD 2x4 SYP SS BRACING
BOT CHORD 2x4 SYP SS TOP CHORD EStructural wood sheathing directly applied or 2-7-13 oc purlins.
WEBS 2x4 SP No.3 BOT CHORD ng directly applied or 4-3-1 oc bradng.SLIDER Left 2x4 SP No.2 3-3-11,Right 2x4 SP No.2 3-3-11 ecommends that Stabilizers and required cross bradng be during Wss erection,in accordance with StabilizerREACTIONS (Ib/size) 2=835/0-58 (min 0-1-8),10=835/0-5-8 (min.0-1-8) on uide.
Max Horz2=12(LC 7)
Max UPIift2=508(LC 6),10=-508(LC 7)
Max Grav2=992(LC 2),10=992(LC 2)
FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 2-15=4514/2195,3-15=-4482/2200,3-4=-4472/2197 4-16=-4920/2289,516=4915/2292,
517=-4361/2080,6-17=-4350/2082,6-18=-4350/2082,7-18=4361/2080,7-19=4915/2292,
8-19=4920/2289,8-9=-4472/2197,9-20=-4482/2200,10-20=4514/2196
BOT CHORD 2-14=2158/4430,13-14=-2471/5121,12-13=2471/5121,10-12=-2158/4430
WEBS 4-14=105/608,513=977/560,6-13=192/493,7-13=-977/560,8-12=105/608
NOTES
1) Unbalanced roof live loads have been considered for this design. ``,��1
2) Wind:ASCE 7-10;Vuft=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf;BCDL=3.Opsf;h=25ft;B=45ft;L=29ft;eave=oft;Cat.II;Exp ,%N� PQU I N
C;End.,GCpi=0.18;MWFRS(directional)and C-C Extenor(2)-1.4-0 to 1-8-0,Intenor(1)1-8-0 to 27-1-0,Exterior(2)27-1-0 to 30-1-0
zone;cantilever left and right exposed,end vertical left exposed;C-C for members and forces 8 MWFRS for reactions shown;Lumber :�� �\Ci•E•I •S�. ;Z �i
DOL=1.60 plate grip D0L=1.60
3)All plates are MT20 plates unless otherwise indicated.
4) This truss has been designed fora 10.0 cast bottom chord live load nonconcurrent with any other live loads. N( 68182
• •� * �_
5) 'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0.0 wide will fit
between the bottom chord and any other members.
6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 508 Ib uplift at joint 2 and 508 Ib uplift at joint
10. T F •:X411
7)"Semi-rigid pitchbreaks inducting heels"Member end fixity model was used in the analysis and design of this truss. O
LOAD CASE(S) Standard �0S� �ID
yin Ai
FL Cert. 6634
March 19,2 13
7-s.—Y
.RARIMG Verify design parameters rind READ NOTES ON THIS AHD INCLUDED MM2r1REF8RENCBPAGE DID-7473 MWORE USCIn valid for use only with MWTek connectors.Th s design is based only upon parameters shown,and is for an individual building component.cabiity of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shownateral support of individual web members only.Additional temporary bracing to insure stability during construction is the res nsibil a.Additional permanent bracing of the overatl shucture is the res Po frty of theation, uai control,story e,deiv ponsibifiy of the building designer.For general guidance regardingMiTek
4 f1' 9 ery,erection and bracing,consutf ANSI/TPII QuoiAly Cdteda,DSM89 aid BCSI Building Component Irdormo8on Ova"loble from Truss Plate Institute781 N.Lee Street,Suite 312,Alexandria,VA 14. 6904 Parke Fest Bivd.thern Pine SP}lumber rs s�cified,tfie design values xe those effective t��/2013 Cy ALSC Tampa,FL 33610-4115
r
Job Truss Truss Type
130517 W Ply RPM 2ND STREET RENOVATION
A02 Hip Truss 2 74765988
1
TRUSSMART BUILDING COMPONENTS, Midway,GA,31320
7-350 s Sep 26 2012 MiTek Industries,Inc. Tue Mar 19 08:46:42 2013 Page
-1.4p 4.65 8-93 ID:TzRDcKdmDnGQMIW86G4k1Z
1.4-p q-05 13-0-0 1Fs-9-p + 19-1113 Y9AC9-Q7asMdkSIMExObntUa341Jh7Yaj9ST2doCzttSzZRF
42-13 42-13 242-11
2�"0 42-13 28-� 30-1-0
4-2-13 4F>-5 1�
Scale=1:51.8
1.00 12
3x4= 4x4= 4x12=
3x4=
i 3x6= 3X6_ W' S 19 6 7 20
'acq�11
1 2 17 3 4 18 8 2x8= 3x6
21 9 10 22 _
� 11 12 1°P
3x4 = Ia
4x12= 16 15
14 3x,1=
3xs= 6x8 MT20H= 44= 13 4x12 =
3x5=
Plate _1
X : Lo-" 6
0_1_121 :0- -0 2-4 11:E 0j4 [12;0-0-120-1A 1 :0
LOADING(psf) SPACING 2-0-0
TCLL 20.0 Plates Increase 1 25 CSI DEFL in (lac) Vdefl L/d
TCDL 7.0 TC 0.84 Vert(LL) 0.941415 >367 240 PLATES Glop
Lumber Increase 1.25 BC 0.57 Vert(TL) -1.58 15 >218 180 MT20 244/790
BCLL 0.0 ' Rep Stress Incr YES MT20H 187/143
BCDL 5.0 Code FRC2010/TP12007 WB 0.29 Horz(TL) 0.20 11 n/a n/a
(Matrix)
LUMBER Weight:136 ib FT=0%
TOP CHORD 2x4 SP N0.21D-Except- BRACING
6-7:2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-0-5 oc purlins,except
BOT CHORD 2x4 SYP SS 2-0-0 oc purlins(2-0-14 Max.):6-7.
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 4-2-15 oc tracing.
SLIDER Left 2x4 SP No.2 3-3-11,Right 2x4 SP No.2 3-3-11 MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection,in accordance with Stabilizer
REACTIONS (lb/size) 2=835/0-5-8 (min.0-1-8),11=835/0-5-8 (min.0-1-8) lastal[ation guide
Max Horz2=12(LC 7)
Max Uplift2=508(LC 6),11=508(1-C 7)
Max Grav2=992(LC 2),11=992(LC 2)
FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 2-17=-4361/2114,3-17=-4329/2118,3-4=-4317/2114,4-18=-4878/2273,518=-4873/2276,
519=4610/2209,6-19=-4599/2210,6-7=-4584/2208,7-20=4606/2213,8-20=-4616/2212,
8 21 4871/2275,9-21=4876/2272,9-10=-4316/2114,10-22=-4328/2118,
11-22=-4360/2113
BOT CHORD 2-16=2076/4274,1516=2494/5170,1415=2157/4590,13-14=2494/5170,
11-13=-2075/4273
WEBS 416=169/661,516=340/277,515=-725/468,7-15=279/269,8-14=721/465,
8-13=343/279,9-13=168/660
•
1
NOTES
1) Unbalanced roof live loads have been considered for this design. `,``�
,O CiEry•N s -. ;Zi
2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101mph;TCDL=4,2psf;BCDL=3.Opsf;h=25ft;B=45ft;L=29ft;eave oft;Cat.II;Exly '
C;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)-1-4-0 to 1-8-0,1nterior(1)1-8-0 to 27-1-0,Exterior(2)27-1-0 to 30-1-0 N 681 82
i
zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber
DOL=1.60 plate grip DOL=1.60 _
3) Provide adequate drainage to prevent water ponding.
4)All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads. T F .' 441
iO
B) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3 6 0 tall by 2-0-0 wide will fit ,�� •' p:•���``
between the bottom chord and any other members. ��
7) Provide mechanical connection(by others)of truss to bpjoint 2 and 508 Ib uplift at joint ISv
11 bearing plate capable of withstanding 508 Ib uplift at '
8)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
9)Graphical purtin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 1j/1111111
LOAD CASES) Standard FL Cert. 6634
March 19,2 13
A AdR1�M -Ver f4f de�ryn parametm,"d;2FAD XOTW ON 7HIS.AND IML uTED AAT&!C
Design valid for use only with Mitek connectors.This design is based on u Pa R�'ER�B PAGE co pone BBPORS IlSB
Applicability of design parameters and proper inc N Pon Parameters shown,and is for a individual building component.
is for lateral supporta-Additional
of component's responsibility of building designer-not truss designer.Bracing shown
of individual web members Doty.gdditional temporary bracing to insure stability during construction is the responsibility,of the
erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding
fabrication,quality control,storage,delivery erection and bracing,consuM ANSI/TPI7 MiTek-
SaMy tetormaXon gvai�able from Truss Plate Institute,781 N.Lee Street,Suite 312 Alexandn'aVq�1 OS6 89 rnW bat Buildi�y Component
H Southern pine;SP.tumtrer s pec ifred,the design vatues are*horse effective Ob/01 j2O13 by AtSt 6904 Park 3 East
Blvd.
l d 5
Truss Truss Type Qty Ply RPM 2ND STREET RENOVATION
A03 Hip Truss 2 1
130517 T4765989
TRUSSMART BUILDING COMPONENTS, Mkhvay,GA,31320 7.350 s Sep 26 2012 MiTek Industries,Inc. Tue Mar 19 08:46:44 2013 Page
ID:TzRDcKdmDnGQMIW86G4k1ZygAWi
C9-NcmJmigzUfgvxFc76YNkn WHINPiwMswGWS_xzzZRF9
f 1.W 57-12 11-0-0 14 4 8 17-9-0 23-1-4 28 9 0 30 1-0
1-4-0 57-12 6-4-4 3�8 3-" 5-4-4 57-12 1-4-0
Stale=1:51.8
1.00 112
4x4= 4x12— 1.5x4 11 4x12 =
44=
3X6- 3x6= 18 4 5 7
No Ra 8 19 9 US_
1 2 17 3 3x6= 20
10 771�
3x4 = �6
16 15 14 13 12 3x4
4x12= =
1.5x4 11 44 = 6x8 MT20H= 4x4= 1.5x4 II 4x12
I 5-7-1 11-0-0 14J-8 17 a.n + 23-1 8-9-0
57-1
Plate offsets 0-1- 10: o-�
LOADING (psf) SPACING 2-0-0 CSI DEFL in (foe) I/defl Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0,70 Vert(LL) 1.05 14 >329 240 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BC 0.56 Vert(TL) -1.77 14 >195 180 MT20H 187/143
BCLL 0.0 ' Rep Stress Incr YES WB 0.27 Horz(TL) 0.21 10 n/a n/a
I BCDL 5.0 Code FRC2010/TPI2007 (Matrix) Weight:130 Ib FT=0%
LUMBER BRACING
TOP CHORD 2x4 SYP SS*Except- TOP CHORD Structural wood sheathing directly applied or 2-3-12 oc purlins,except
5-7:2x4 SP No.2 2-0-0 oc purlins(2-2-15 max.):5-7.
BOT CHORD 2x4 SYP SS BOT CHORD Rigid ceiling directly applied or 4-4-9 oc bracing.
WEBS 2x4 SP No.3 [installed
iTek recommends that Stabilizers and required cross bracing be
SLIDER Left 2x4 SP No.2 3-3-11,Right 2x4 SP No.2 3-3-11 during truss erection,in accordance with Stabilizer
s i
REACTIONS (lb/size) 2=835/0-5-8 (min.0-1-8),10=835/0-5-8 (min.0-1-8)
Max Horz2=12(LC 7)
Max Uplifl2=507(LC 6),10=507(LC 7)
Max Grav2=992(LC 2),10=992(LC 2)
FORCES (Ib)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 2-17=4735/2251,3-17=-4702/2253,318=-4698/2253,4-18=-4687/2254,4-5=-5040/2418,
5-6=5120/2477,6-7=5120/2477,7-8=504012418,8-19=X687/2254,9-19=-4698/2253,
9-20=-4702/2253,10-20=4735/2251
BOT CHORD 2-16=2216/4658,1516=2216/4658,14-15=2373/5017,1314=2373/5017,
12-13=-2216/4658,10-12=2216/4658
WEBS 4-15=205/713,514=125/426,7-14=125/426,8-13=205/713
NOTES `�OPQv I N
) Unbalanced roof live bads have been considered for this design %%
2) Wind:ASCE 7-10;Vutt=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf,BCDL=3.Opsf,h=25ft;B=45ft;L=29R;eave=4ft;Cat.II;Exp`% , �\C•E N S�. •,� i;/
C;End.,GCpi=0.18;MWF RS(directional)and C-C Exterior(2)-1-4-0 to 1-8-0,1nterior(1)1-6-0 to 27-1-0,Extehor(2)27-1-0 to 30-1-0
zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber N( 68182
DOL=1.60 plate grip DOL=1.60 * •;
3) Provide adequate drainage to prevent water ponding.
4)All plates are MT20 plates unless otherwise indicated. ;
5) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads. r �
-10
6) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit F
between the bottom chord and any other members.
7) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 507 Ib uplift at joint 2 and 507 Ib uplift at joint �i •' P••\���,
10. �� is'• G �%
8) "Semi-rigid pitchbreaks induding heels"Member end fixity model was used in the analysis and design of this truss. •
9) Graphical puriin representation does not depict the size or the orientation of the pudin along the top and/or bottom chord.
LOAD CASE(S) Standard
FL Cert. 6634
March 19,2 13
A IAARAITAG Verify design pmw-.,ten,rnd READ NO;rES r?N 7777S dND INCLUDED 1477EdCRi8FBRMWE PAGE AW 7473 BiIWORE USE.
Design void for use only with MTek connectors.This design is based only upon parameters shown,and is for an individual building component.
Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown
B for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibilfity of the
erector.Addifional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding MI lek
fabrication,quality,control,storage,delivery,erection and bracing,consult ANSVrM1 QudUy Oftwic,DSB-8f and BCSI Building Component 6904 Parke Fast Blvd.
if�Swi �jSFt Lumber is s�laF Institute,Ove 781 N.Lee Sheet,Suite 312 Alexandria,VA J2314. Tampa,FL 33610-4115
d+si`n war
Nres e ttwse a4factive 06y01/2033 toy A15C
glob • Truss Truss Type Qty Ply RPM 2ND STREET RENOVATION
130517 A04 Hip Truss2 1 T4765990
TRUSSMART BUILDING COMPONENTSMidway,way,GA,31320 7.350 s Sep 26 2012 MiTek Industries,Inc. Tue Mar 19 08:46:47 2013 Page
2 47.12 ID:TzRDcKdmDnGQMIW86G4k1ZygAC9-n5O1PKoa7usDXMggH8fF?NP?FbQZ7gJMyUgeYlzZRF
14-0 47-12 44q 1 1 2 28 9-0 30-1-0
54-8 47-12 1-4-0
Scale=1:51.8
1.00 12
3x6 = 3x5= 4x12 = 1.5x4 II
4x12= 3x6_
15 3 4 16 5 7 1 7 t9 89 3x6= 20
1 2 3x6
3x6
Feg
10 11 �
3x4 - lopY
4x12= 14 13 72 3x4=
4x4= 6x8 MT20H4x4= 4x12=
=
9-041 14A-8 19-M
53 8 `5 a 9-0-0
Plate is X 1-1 r10:0-M-0-2-41
LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.72 Vert(LL) 1.09 13 >316 240 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BC 0.55 Vert(TL) -1.83 13 >188 180 MT20H 187/143
BCLL 0.0 Rep Stress Incr YES WB 0.48 Horz(TL) 0.20 10 n/a n/a
BCDL 5.0 Code FRC2010/TPI2007 (Matrix) �— Weight:134 Ib FT=0%
LUMBER BRACING
TOP CHORD 2x4 SYP SS TOP CHORD Structural wood sheathing directly applied or 2-5-13 oc purlins,except
BOT CHORD 2x4 SYP SS 2-0-0 oc purlins(2-4-4 max.):5-7.
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 43-9 oc bracing.
SLIDER Left 2x4 SP No.2 3-3-11,Right 2x4 SP No.2 3-3-11 MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection,in accordance with Stabilizer
REACTIONS (Ib/size) 2=835/0-5-8 (min.0-1-8),10=835/0-5-8 (min.0-1-8) Installation guide
Max Horz2=9(LC 7)
Max UpIif12=508(1-C 6),10=-508(LC 7)
Max Grav2=992(LC 2),10=992(LC 2)
FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 2-15=-4324/2154,3-15=4292/2158,3-4=-4279/2152,416=5252/2474,5-16=5244/2477,
5-17=5989/2904,6-17=5989/2904,6-18=-5989/2904,7-18=5989/2904,7-19=5244/2477,
8-19=5252/2474,8-9=-4279/2152,9-20=-4292/2158,10-20=-4324/2154
BOT CHORD 2-14=2113/4236,13-14--2438/5226,12-13=2438/5226,10-12=2113/4236
WEBS 4-14=32711264,5-13=465/1084,B-13=-291/194,7-13=-46511084,8-12=-327/1264
NOTES `
1) Unbalanced roof live loads have been considered for this design. ��� v 1 N
2) Wind:ASCE 7-10;Vuft=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf,BCDL=3.Opsf;h=25ft:B=45ft;L=29ft;eave=oft;Cat.II;Exp %% 0 •' •• ��,�j
C;End.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)-1-4-0 to 1-8-0,Interior(1)1-8-0 to 27-1-0,Exterior(2)27-1-0 to 30-1-0 :�� ,••'�\`'E•N S�••,� ��'
zone;cantilever left and right exposed,end vertical left exposed,C-C for members and forces&MWFRS for reactions shown,Lumber
DOL=1.60 plate grip DOL=1.60 4 N( 68182
3) Provide adequate drainage to prevent water ponding. * :• •;
4)All plates are MT20 plates unless otherwise indicated.
5)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. .O
6) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3 6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members. . '. T F .
7) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 508 Ib uplift at joint 2 and 508 Ib upliftat joint �� •••T O Q' ;��
10.
8)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. ,���Sl7 •t\C'J�`%
9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
LOAD CASE(S) Standard
FL Cert. 6634
March 19,2 13
AWARMNG Ver fy dcgm panmutem and READ NOTES ONTWS ARID INCLUDED IOTEKREFEREWE PAGE W1 7373 BEFORE USE. e�
Design valid for use only with MTek connectors.This design is based only upon parameters shown,and is for an individual building component.
Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown
is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the M Tek
erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding
fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/rP11 QuaNy CrIlede,OS549 and BCSI Building Componentsafety 6gp4 Parke Fast Blvd.
if ttr trrn pintegygilq l�russ plate Institute,781 N.Lee Street,Surfe 312 Alexandria,VA 2231. A Tampa,FL 33610.4115
iSP)I WecWod.tfie design ghres are thoso eill ve 06(01 2013 bV
Job Truss Truss Type Qty ply RPM 2ND STREET RENOVATION
130.517 A05 HIP TRUSS 74765991
_ 2 4
TRUSSMART BUILDING COMPONENTS, Midway,GA,31320 7.350 s Sep 26 2012 MTek Industries,Inc. Tue Mar 19 08:46:52 2013 Page
NOTES ID:TzRDcKdmDnGQMI W86G4kl ZygAC9-82BeS2sjyRV Wd8Yo4hFQiQ6rfc2gGyP5610PDNhZRF 1
8) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 1235 Ib uplift atjoint 2 and 1235 Ib uplift at joint 11.
9)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
10)Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
11)"NAILED"indicates 3-10d(0.148"x3")or 3-12d(0.148"x3.25")toe-nails.For more details refer to MiTek's ST-TOENAIL Detail.
12)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)409 Ib down and 253 Ib up at 7-",and 409 Ib down and 253 Ib up at 21-8-4
on bottom chord. The design/selection of such connection device(s)is the responsibility of others.
LOAD CASE(S) Standard
1) Regular.Lumber Increase=1.25,Plate Increase=1.25
Uniform Loads(pit)
Vert-.1-5=-44,5-8=44,8-12=-44,2-11=-10
Concentrated Loads(lb)
Vert:17=347(B)5=106(13)8=106(B)14=347(8)20=106(6)21=106(B)22=106(B)23=106(8)24=106(6)25=106(B)26=106(6)28=22(13)29=-22(B)30=22(B)
31=-22(B)32=22(B)33=-22(B)34=22(B)
011111 1111111,f
.`N�OP:4 '
EN
`` , .•���• • SF•. ��
N 68182
�-10�
�:• T F �:
FL Cert. 6634
March 19,2 13
®WARMNG Verify deign para weters and READ NOTES ON THIS AND INCLUDED M7EK REFERENCE PAGE N+I 7473 WORE USE.
Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component.
Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown
is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the Ml lel
erector.Additional permanent bracing of the overall structure is the responsibility of the buiking designer.For general guidance regarding
fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/rPtl Quality Criteria,DSB-89 and SCSI Building Componwd 6904 Pa
Sdefy Informa8on cava ble from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA 314. Tampa,Parke
33610-4115
if Southern pine 1 dumber is specifred,rice design+akws are those effective 06 e East Blvd.
01/2013 by ALSO Tampa,
.bb Truss Truss Type Qty Ply RPM 2ND STREET RENOVATION
130517 J02 Jack-Open Truss 8 1 74765992
Job Reference(QpWnal)
TRUSSMART BUILDING COMPONENTS, Midway,GA,31320 7.350 s Sep 26 2012 MiTek Industries,Inc. Tue Mar 19 06:46:53 2013 Page
ID:TzRDcKdmDnGQMIW86G4kl ZygAC9-cElOfOtLjkdNFH7_dOmfFee9hobPXVKE1p7zrnyzZRF
11-0 2-10-15
1.4-0 2-10-15
1.00 12 Scale=1:6.2
2 3
1
3x4= 4
Refer to MiTek"TOE-NAIL"Detail for connection to
supporting Carrier truss (typ all applicable jacks on this job)
�-- -10-15
10-15
LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0 21 Vert(LL) -0.00 2 >999 240 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BC 0.01 vert(n) -0.00 2 >999 180
BCLL 0.0 ' Rep Stress Ina YES WB 000 Holz(TL) -0.00 3 n/a n/a
BCDL 5.0 Code FRC2010/TP12007 (Matrix) Weight:13 Ib FT=0%
LUMBER BRACING - —
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-10-15 oc purlins.
BOT CHORD 2x6 SYP SS BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 3=39/Mechanical,2=166/0-8-0 (min.0-1-8),4=4/Mechanical
Max Horz2=20(LC 7)
Max Uplift3=43(LC 7),2=-194(LC 6)
Max Grav3=48(LC 2),2=200(LC 2).4=34(LC 3)
FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
NOTES
1)Wind:ASCE 7-10,Vutt=130mph(3-second gust)Vasd=101 mph,TCDL=4.2psf;BCDL=3.Opsf,h=25ft;B=45ft;L=24ft;eave=oft;Cat.11;Exp
C'End.,GCpi=0.18'MWFRS(directional)and C-C Exterior(2)zo�e;cantilever left and right expose�.end vertical 1.ft expose�,C-C for
members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip D0L=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads-
3) 'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s)for truss to truss connections.
5) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 43 Ib uplift at joint 3 and 194 Ib uplift at joint 2. t,111111111111
6) "Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. �� //
LOAD CASE(S) Standard ���OPa G!E N
N 68182
T F
i,40�'S,S
//�IIn►��
FL Cert. 6634
March 19,2 13
A`AA.RKAIG Ve"fjy deign parameters and READ NOTES ON TWS AND DYCLUDED JUTBK REFERENCE PAGE/Cf 7473 BEFORE USB }}
Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. 7
Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown d
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillty of theI'
erector.Additional permanent bracing of the ovemil structure is the responsibility of the bulking designer.For general guidance regarding M17e kl..
fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TM Quality Criteria,1%6-89 and 1ICSI Building Component 6904 Parke East Blvd.
if Sauthe .SP�lumtaer is Truss
fiedtitihe desWeva taret"wi eAlexa
e#active a/vIA013 by ALSO Tampa,FL 33610-4115
Job ��JO�4 ��Ja_c�k=-Open
Qty PN RPM 2ND STREET RENOVATION
74765993
130517• ss 8 1
Job Reference(optional)
?RUSSMART BUILDING COMPONENTS,Midway,GA,31320 7.350 s Sep 26 2012 MiTek Industries,Inc-Tue Mar 19 09:49:04 2013 page t
ID:TzRDcKdmDnGOMIW86G4k1ZygAC9-ZwMODj7O6X7P91 VGAUhuAQgiV7ymDvzPH000CCzZQKj
14-0
1 410-15
—
410-15 — _--
i
Scale=1:11.6
1.00 12
3x4=
3 4
3x4 =
2
1
4x8 = 3x4= 5
Plate Offsets(X.Y): r2:04-0.0-1-81 4-10-15
LOADING (pst) SPACING 244-0 CSI DEFL in (roc) Udefl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.31 Vert(LL) -0.02 2-5 >999 240 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BC 0.17 Vert(TL) -0.04 2-5 >999 180
BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 4 Na n/a
BCDL 5.0 Code FRC2010lrP12007 (Matrix) Weight.22 Ib FT=0%
LUMBER BRACING
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 410-15 oc purlins.
BOT CHORD 2x4 SP Not BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
SLIDER Left 2x4 SP No.2 3-3-11
REACTIONS (Ib/size) 4=99/Mechanical,2=198/0-5-8 (min.0-1-8),5=24/Mechanical
Max Horz 2=29(LC 7)
Max Uplift 4=100(1_C 7),2=193(LC 6)
Max Grav 4=120(LC 2),2=237(LC 2),5=65(LC 3)
FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
NOTES
1) Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf;BCDL=3.Opsf;h=25ft;13=45ft;L=24ft eave=oft;Cat.II,
Exp C,End.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)zone;cantilever left and right exposed;end vertical left
exposed;C-C for members and forces 8 MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom Chord live load nonconcurrent with any other live loads.
3) 'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
4) Refer to girder(s)for truss to truss connections.
5) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 Ib uplift at joint 4 and 193 Ib uplift at %%% ,1 N ���
joint 2. ` Q.Q V F( i.,
6) "Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. CEN•••, ����
LOAD CASE(S) Standard N 68182
O:• T F :�41J
FL Cert. 6634 I
March 19,2013
0 WARNING Verify design parmnetem and READ NOTES ON THIS AND TNCLUDED W=REFERENCE PAGE AffI-7473 BEFORE ONE
Design void for use only with MTek connectors.This design is based only upon parameters shown,and is for an individual building component.
Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown
is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction Is the responsibility of the MiTek
erecta.Additional permanent bracing of the overall structure s the responsibility of the building designer.For general guidance regarding
fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPil Quality Crawla,DSA-89 and SCSI Building Componerd 6904 Parke East Blvd.
Sally InfdmaHon qva bie from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria,VA X1314. Tampa,Parke
3 East
Blvd.
15
if iauihern Pine 15a)lumber�z specified,tfie design values are those effective 06/01J2013 by ALK
�13051?�- �'��J07�
Truss Type Qty Ply RPM 2ND STREET RENOVATION
T4765994
Jack-Open Truss 18 1
Job Reference a
TRUSSMART BUILDING COMPONENTS,Midi W,GA,31320 7.350 s Sep 26 2012 Mi rek Industries.Inc.Tue Mar 19 09:49:13 2013 Page 1
ID:TzRDcKdmDnGQMIVW6G4kl ZygAC9-oePQ6oEi_IG8kQh?Btt-?2KYDId_xq_CkLH5sOAzZQKa
-14-0 7.0-0
140 7-0-0
Scab=1:15.5
1.00 52
4x4=
3 4
7 4x4=
6
2
1
3x8= 3x10 II 5
7-0-0
7-0-0
Plate onsets a Yt: r2:0-3-4.o-0-41 1`2:o-o-6 0-7-81 f2:3-10-1 0-1-81
LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Vdefl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.53 Vert(LL) -0.09 2-5 >883 240 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BC 0.36 Vert(TL) -0.17 2-5 >491 180
BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 4 Na We
BCDL 5.0 Code FRC2010ITP12007 (Matrix) Weight 36 Ib FT=0%
LUMBER BRACING
TOP CHORD 2x4 SP No.2 TOP CHORD Stnictural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
SLIDER Left 2x6 SYP SS 5-5-13
REACTIONS (Ib/size) 4=150/Mechanical,2=252/048-0 (min.0-1-8),5=32/Mechanical
Max Hort 2=39(LC 7)
Max Uplift 4=150(LC 7),2=230(LC 6)
Max Grav 4=182(LC 2),2--301(LC 2),5=91(LC 3)
FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown.
NOTES
1)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf,BCDL=3.Opsf,h=25ft;B=45ft;L=24ft;eave=oft;Cat.II;
Exp C;End.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)-1-4-0 to 1-8-0,Interior(1)1411-0 to 2-8-5,Exterior(2)24!1-5 to 6-11-4
zone;cantilever left and right exposed;end vertical left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber
DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
ft between the bottom chord and any other members. 1111111►//�11/
4) Refer to girder(s)for truss to truss connexons. `.
5) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 150 Ib uplift at joint 4 and 230 Ib uplift at ,`
joint OPQU N �
i
�. .•'\CENS'• � �.
6)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. ; .• �, $
LOADCASE(S) Standard Nc 68182
1/1111111��
FL Cert. 6634
March 19,2013
AWARNIM Verify design parameters and READ NINES ON TWIS AND INCLUDED IQTEK REFERENCE PAGE AU 7473 BEFORE USE. o
Design valid for use only with MTek connectors.This design is based only upon parameters shown,and is for an indrvidual building component.
Applicability of design parameters and proper incorporation of component's responsibility of building designer-not truss designer.Bracing shown
is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibility of the
erector.Additional permanent bracing of the overall structure is the responsibiity of the building designer.For general guidance regarding MiTek
fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/rPll Qucft Criteria,DSB-89 and BCSI 8ugding Component 6904 Parke Fast Blvd.
Sally Into 31— qva' bre from Truss Plate Institute,781 N.Lee Street,Suite 312 Alexandria,VA 22314. Tampa,FL 336104115
If Sovtfurn pine Sv9VN�mber is specified.the design varies are those elFective 0614]x`2013 by ALSO
ADb
' • 4 Truss Truss Type Qty Ply RPM 2ND STREET RENOVATION
130517 JC09 Diagonal Hip Girder 4 1 T4765995
TRUSSMART BUILDING COMPONENTS, Midway,GA,31320 7.350s Sep 26 2012 MTek Industries,Inc. Tue Mar 19 08:46:56 2013 Page
ID:TzRDcKdmDnGQMI V486G4kl ZygAC9-OpQ91PvE?f?y6lsZJXJMsGGZQDV?knGhONMdLHZZR
1-1010 41010
1-10-10 4-10-10 - 4-10-10
Scale=1:21.5
NAIL2671 F12 NAILED
NAILED NAILED 4x4 11
NAILED 3x4= 12 4 5
11 3
NAILED 4x4=
2 4x12 =10
1
3x4=
13 14 9 8 15 7
NAILED 3x4= 1.5x4 II NAILED 6
NAILED NAILED NAILED 4x4=
NAILED
4-10-IQ 5
_.
Plate Offsets X 2:0-4-10 0-2-0 4:0-2-0 0-1-12 :0.1-8 0-2-0 4-10.10 410.10
LOADING (psf) SPACING 2-0-0 CSI
DEF
in (loc) I/deft L/d PLATES GRIP
_7
TCLL 20.0 Plates Increase 1.25 TC 0.69 Vert(LL) 0.10 8 >999 240 MT20 244/190
TCDL 7.0 Lumber Increase 1.25 BC 0.53 Vert(TL) O.t4 7-8 >816 180
BCLL 0.0 ' Rep Stress Incr NO WB 0.37 Horz(TL) 0.02 7 n/a n/a
BCDL 5.0 Code FRC2010/TP12007 (Matrix) Weight:46 Ib FT=D%
LUMBER
BRACING
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-3-13 oc purlins, except
BOT CHORD 2x4 SP No.2 end verticals.
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 6-8-2 oc bracing.
SLIDER Left 2x4 SP No.2 4-6-1
REACTIONS (Ib/size) 7=335/Mechanical,2=292/0-6-0 (min.0-1-8)
Max Horz2=38(LC 5)
Max Uplift7=251(LC 5),2=299(LC 4)
Max Grav7=397(LC 2),2=364(LC 2)
FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 2-10=1190/706,1 0-1 1=1 1 7817 1 7,3-11=-1169/720,3-12=327/190,4-12=312/185
BOT CHORD 2-13=741/1169,13-14=741/1169,9-14=741/1169,8-9=741/1169,8-1 5=74111169,
7-15=741/1169
WEBS 3-7=860/551
NOTES
1)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf;BCDL=3.Opsf;h=25ft;B=45ft;L=24ft;eave=oft;Cat.Il;Exp 11111111/�
C;Encl.,GCpi=0.18;MWFRS(directional),cantilever left and right exposed end vertical left exposed;Lumber DOL=1.60 plate grip X11 I�
DOL=1.60 �� QV IN
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. OP , , F��.
3) 'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will ft ,�� ,•,•�\CE IV
5+�. •� ��,
between the bottom chord and any other members. �.
4) Refer to girder(s)for truss to truss connections. N( 68182
5) Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 251 Ib uplift at joint 7 and 299 Ib uplift at joint * :• •;
2. _
6)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
7)"NAILED"indicates 3-10d(0.148"x3")or 2-12d(0.148"x3.25")toe-nails. For more details refer to MiTek's ST-TOENAIL Detail
8) In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). i •, T F Z
LOAD CASE(S) Standard jO ••. Q`.• ���
i O -•` \
1) Regular:
rm Load34e45=14 2 60
Plate 2
Vert
1ncase=1.25
Uniform s AL %�\
Concentrated Loads(Ib)
//11111111
Vert:10=61(F=30,B=30)11=9(F=5,B=5)12=109(F=-55,B=55)13=35(F=18,B=18)14=9(F=4,B=4)15=28(F=14,B=-14)
FL Cert. 6634
March 19,2 13
AkFARMM Veldt!dmt9R Parwweters and iMD NOTES ON nVS AND INCLUDED MIT EK R£FEREWS PAGE 191 7473 HBFORS EISR
Design valid for use only with h4Tek connectors.This design B based only upon parameters shown,and is for an individual building component.
Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown
B for literal support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the
erector.Additional permanent tracing of the overall structure is the responsibility of the building designer.For general guidance regarding M!Te k
fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/rPll Quality Criteria,DSB-89 and SCSI Building Component 6964 Parke East Blvd
Sally IrdormaSon va' bie from Truss Plate Institute,781 N.Lee Street,Suite 312 Alexandria,VA 22314.
tf Southern Pine�SR lumber is specified the 6es4n values are those e4Fective 06J01i2013 by ALSO Tampa,FL 33610-4115
rirL1;� CITY OF ATLANTIC BEACH
S, Building Department _
800 Seminole Road *�
;r Atlantic Beach,Florida 32233
(904)247-5800
PLAN REVIEW COMMENTS
Permit Application # /3 —J*)J
Property Address: 33 / p?n CJ'
Applicant: Q to In S /6 c e Vi C4
Project: dd v �;o ma F.
This permit application has been:
0 Approved
E:1 Reviewed and the following items need attention:
D►.a n
S /o isd 5c. r i , i -iS -7
Qi PP ~
y fs .3
v ✓ C iGn
CIL-
o kc
C9G
Please re-submit your application
application when these items have been completed.
Reviewed By: . 1 Date: e7'-z,2 -/ ,3
PLOT PLAN
LOT 8, EXCEPT THE SOUTH 10 FEET, BLOCK 4, SUBDIVISION "A" ATLANTIC BEACH AS RECORDED IN
PLAT BOOK 5, PAGE 69 OF THE CURRENT PUBLIC
City Of Atlan f is Beach
� .r..r..� a.� Planning and Zoning Department
This approval verifies compliance with applicable
zoning, subdivision and other local land
�� development regulations, but does not constitute
FILE 1 approval fVhegssuance of permits. Compliance
with Florid uilding Code and all other applicable
local, State and Federal permitting requirements
LOT 9 !must b verified by signature of the City of Atlantic
FIELD ) 1 f�'�D' uil O#ieiar for to the issuance of a
( 50.00 ,
2 IRON 50.00 1 InC1 ,e flit.
FOUND N UK FENCE 6 L
PIPE NO CAP 0.9' S'CFW
iP90 �g pproved By: ctor
-- �- .".
s ate:
I �
LOT
S 0 13- tad A
x 18 7,000 SQ. FT
TOTAL LOT AREA
G 523 FT.IMPERVIOUS AREA
3 50� COVERAGE
5.7 m
1
I
D.: s PROPOSED
° ADDITION
c
o P
v �
LOT 6
^ � I
o' 5.7' 2&7' I
LOT 10 m C) 5 1 o
nt.
O P. o
o y
1-STORY BLOCK x' p
N
RESIDENCE No.331 f "�
y CHAIN UNK FENCE
5.7'
ze.r I A
I 6•WOOD FENCE (d
O 0
ICK PAbER 1 =
P O
W x 0!
£
tea'' FIELD G
50.00 a1 _150- --
FIELD ) IRON
0� ( 50.06' FOUND ,2
O PIPE,LB. —�
O
— FOUND t�C IRON o S orHLOTO 8E � ____— —
— PIPE.NO W
NORTH RIAY LINE PER PLAT 1*1
RIGHT OF E
_--------- S T R E
S E C ON D (PAVED)
40' RIGHT OF WAY
NOTES
THIS IS A BOUNDARY SURVEY.
ANGLES AS PER FIELD SURVEY. Q 10 20 40
NO BUILDING RESTRICTION LINES PER PLAT.
NORTH IS APPROXIMATE. SCALE: 1" = 20'
THE PROPERTY SHOWN HEREON APPEARS TO
LIE IN FLOOD ZONE "X" (AREA OUTSIDE 500
YEAR FLOOD PLAIN) AS WELL AS CAN BE
DETERMINED FROM THE FLOOD INSURANCE
RATE MAP COMMUNITY PANEL No. 120075
0001 D, REVISED APRIL 17, 1989 FOR THE
CITY OF ATLANTIC BEACH, DUVAL COUNTY,
FLORIDA.
"NOT VALID WITHOUT THE SIGNATURE AND DONN W. BOATWRIGHT, P.S.M.
THE ORIGINAL RAISED SEAL OF A FLORIDA BOUNDARY SURVEY RECHECK - FLORIDA LIC. SURVEYOR and MAPPER No. LS 3295
LICENSED SURVEYOR AND MAPPER." MARCH 8, 2013 FLORIDA LIC. SURVEYING @ MAPPING BUSINESS No. LB 3672
CHECKED BY: BOATWRIGHT LAND SURVEYORS, INC. DATE:
DRAWN BY: SWD MAY 16 z000
FILE: 2013-0164 1500 ROBERTS DRIVE, JACKSONVILLE BEACH, FLORIDA 241-8550 SHEET OF
2000-0354
CITY OF ATLANTIC BEACH
j 800 SEMINOLE ROAD
J = ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 13-00002403 Date 4/30/13
Property Address . . . . . . 331 2ND ST
Application type description RESIDENTIAL ADDITION
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 49000
----------------------------------------------------------------------------
Application desc
865 SF Addition to rear of dwelling
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
SLUZEVICH AARON OWNER
331 2ND ST
ATLANTIC BEACH FL 322335229
--- Structure Information 000 000 REAR ADDITION 865 SQ FT
Construction Type . . . . . TYPE 5-A
Occupancy Type . . . . . . RESIDENTIAL
Flood Zone . . . . . . . . ZONE X
----------------------------------------------------------------------------
Permit . . . . . . PLUMBING PERMIT
Additional desc . . 14 FIXTURES
Permit Fee . . . . 153 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 10/27/13
----------------------------------------------------------------------------
Special Notes and Comments
If on-site storage is required, a post construction
topographic survey documenting proper construction will be
required.
Roll off container company must be on City approved list
and container cannot be placed on City Right-of-Way.
(Approved: Advanced Disposal, Realco, Shappelle ' s and Waste
Management . )
Full erosion control measures must be installed and
approved prior to beginning any earth disturbing
activities . Contact Public Works (247-5834) for Erosion
and Sediment Control Inspection prior to start of
construction.
2010 FLORIDA BUILDING CODE, 2008 NATIONAL ELECTRIC CODE
*REPORT ANY UNFORSEEN STRUCTURAL DAMAGE TO THE BUILDING
DEPARTMENT IMMEDIATELY.
WINDOW AND DOOR INSPECTION:
*INSTALLATION INSTUCTIONS REQUIRED
*ALL STICKERS ARE TO REMAIN ON THE WINDOWS
*PROVIDE ACCESS TO ALL WINDOWS TO INSPECT FASTENERS
PERMIT THE FLORIDA
BUILDING CODES.
J� Yea $N,.,: *�
t11 CITY OF ATLANTIC BEACH
j 800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
,�nvJ!tit
Page 2
Application Number . . . . . 13-00002403 Date 4/30/13
----------------------------------------------------------------------------
Special Notes and Comments
CONTROL COMPANY PRIOR TO C.O.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE PLBG DCA SURCHARGE 2 . 30
STATE PLBG DBPR SURCHARGE 2 . 30
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 153 . 00 153 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 60 4 . 60 . 00 . 00
Grand Total 157 . 60 157 . 60 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
PLUMBING PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904)247-5826 Fax(904)247-5845
,TOB ADDRESS:_2 3/ d-,v 57-1{E,;7— ljf7-e4 ,71r ,Q��3cf U 33 PERMrr#
NEW OR REPLACEMENT INSTALLATION: Project Value$ 8�cry.
TYPE OF FIXTURE QTY TYPE OF FIXTURE QTY
Bathtub a2 Septic Tank&Pit
Clothes Washer Shower
Dishwasher Shower Pan
Drinking Fountain Slop Sink
Floor Drain Three Compartment Sink
Floor Sink Toilet
Hose Bibs �— Urinal
Kitchen Sink Vacuum Breakers
Laundry Tray Water Connected Appliances
Lavatory _� Water Heater
Other Fixtures Water Treating System
RE-PIPE:
TYPE OF FIXTURE QTY TYPE OF FIXTURE QTY
Bathtub Septic Tank&Pit
Clothes Washer Shower
Dishwasher Shower Pan
Drinking Fountain Slop Sink
Floor Drain Three Compartment Sink
Floor Sink Toilet
Hose Bibs Urinal
Kitchen Sink Vacuum Breakers
Laundry Tray Water Connected Appliances
Lavatory Water Heater
Other Fixtures Water Treating System
MISCELLANEOUS:
❑ Sewer Replacement ❑ Back Flow Preventer ❑ Grease Interceptor(Trap) gallons(Requires 3 sets of plans)
❑ Lawn Sprinkler System-Number of Heads ❑ Well **
**SJR WD Well Completion Form. Completed form to be submitted to the Building Department for final inspection.**
❑ Other
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified
or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name A/31o,J SCt)ze✓JC/ Phone Number/y -30'1� -Q 916a
Plumbing Company 011( rich Office Phone Fax
Co. Address: City State Zip
License Holder(Print): State Certification/Registration#
Notarized Signature of License Holder
Befaire, i s v t_ 20
MY COMMISSION is [1957
Sign` NO€ ry t A
'•.�p�•�y,,• Bonded hru ota
, CITY OF ATLANTIC BEACH
s 800 SEMINOLE ROAD
"J ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
JA19
Application Number . . . . . 13-00002403 Date 4/30/13
Property Address . . . . . . 331 2ND ST
Application type description RESIDENTIAL ADDITION
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 49000
----------------------------------------------------------------------------
Application desc
865 SF Addition to rear of dwelling
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
SLUZEVICH AARON OWNER
331 2ND ST
ATLANTIC BEACH FL 322335229
--- Structure Information 000 000 REAR ADDITION 865 SQ FT
Construction Type . . . . . TYPE 5-A
Occupancy Type . . . . . . RESIDENTIAL
Flood Zone . . . . . . . . ZONE X
----------------------------------------------------------------------------
Permit . . . . . . ELECTRICAL PERMIT
Additional desc . .
Permit Fee . . . . 104 .40 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 10/27/13
----------------------------------------------------------------------------
Special Notes and Comments
If on-site storage is required, a post construction
topographic survey documenting proper construction will be
required.
Roll off container company must be on City approved list
and container cannot be placed on City Right-of-Way.
(Approved: Advanced Disposal, Realco, Shappelle ' s and Waste
Management . )
Full erosion control measures must be installed and
approved prior to beginning any earth disturbing
activities . Contact Public Works (247-5834) for Erosion
and Sediment Control Inspection prior to start of
construction.
2010 FLORIDA BUILDING CODE, 2008 NATIONAL ELECTRIC CODE
*REPORT ANY UNFORSEEN STRUCTURAL DAMAGE TO THE BUILDING
DEPARTMENT IMMEDIATELY.
WINDOW AND DOOR INSPECTION:
*INSTALLATION INSTUCTIONS REQUIRED
*ALL STICKERS ARE TO REMAIN ON THE WINDOWS
*PROVIDE ACCESS TO ALL WINDOWS TO INSPECT FASTENERS
PERMIT IS*56ORKIff THE FLORIDA
BUILDING CODES.
CITY OF ATLANTIC BEACH
j 800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
'r�Ji31��
Page 2
Application Number . . . . . 13-00002403 Date 4/30/13
----------------------------------------------------------------------------
Special Notes and Comments
CONTROL COMPANY PRIOR TO C.O.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE ELEC DCA SURCHARGE 2 . 00
STATE ELEC DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 104 .40 104 . 40 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 108 .40 108 . 40 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
ELECTRICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd,Atlantic Beach,FL 32233
Ph(904)247-5826 Fax(904)247-5845
.SOB ADDRESS: 33/ �' �S%�«i /,7 I'll-'77� , C/7� � 3aPERMIT#
JEA INFORMATION REQUIRED ON ALL PERMITS AMPS VOLTS PHASE
VALUE OF WORK S 7 cO, '
NEW SERVICE ❑ Overhead ❑ Underground ❑J Underground up Pole
❑Residential(Main)Service
J0-100 amps 0101-150amps ❑151-200amps ❑ amps #of Meters
CCommercial(Main)Service
❑0-100 amps 1110 1-1 50amps ❑151-200amps ❑ amps OCT Service amps
Conductor Type Size
F--Multi-Family(Main)Service
110-100 amps ❑101-150amps ❑151-200amps ❑ amps #of Unit Meters
❑Temporary Pole ❑ amps
SERVICE UPGRADE 1-7 amps ❑ CT Service amps
NEW FEEDER(ADDITIONS,ACCESSORY STRUCTURES,ETC.)
,71 100 amps ❑150amps C:200amps ❑ amps OCT Service amps
ADDITIONS,REMODELS,,8EPAIRS,BUILD-OUTS,ACCESSORY STRUCTURES,ETC.
Outlets/Switches: 0-30amps 31-100amps 101-200amps
Appliances: 0-30amps 31-100amps 101-200amps
A/C Circuits: / 0-60amps 61-100amps
Heat Circuits: # circuits @ kw
Number of Lighting Outlets, Including Fixtures: `S
OTHER ELECTRICAL PROJECTS
0'Swimming Pool ❑ Sign ❑SmokeDetectors_Qty ❑Transformers KVA Ll Motors hp
FIRE ALARM SYSTEM (Requires 3 sets of plans)
Qty volts/amps VALUE OF WORK S
REPAIRS/MISCELLANEOUS
❑Replace Burnt/Damaged Meter Can ❑Safety Inspection ❑Panel Change 0 O to UG
❑Other:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have
read this application and know the same to be true aid correct. All provisions of laws and ordinances governing this work will be complied with whether
specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of
construction.
Property Owners Name /�AQoJ S�c <</ICS Phone Number
Electrical Company D(��Jf Office Phone Fax
Co. Address: City State Zip
License Holder(Print): State Certification/Registration#
Notarized Signature of License Holder
A4Y HA
Sig# -ofj �"
Eionoed Thru Notary Public Unoerwr to s