Loading...
Permit HVAC 331 2nd St 2013 CITY OF ATLANTIC BEACH j 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 moil Application Number . . . . . 13-00002013 Date 1/17/13 Property Address . . . . . . 331 2ND ST Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ----------------------------'------------------------------------------------ Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ----------------------- ------------------------ SLUZEVICH AARON TROPIC HEATING & AIR 331 2ND ST 750 MAYPORT RD ATLANTIC BEACH FL 322335229 ATLANTIC BEACH FL 32233 (904) 241-1788 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 99 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 7/16/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 99 . 00 99 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 103 . 00 103 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax(904) 247-5845 / JOB ADDRESS: 3 s c `r PERMIT# PROJECT VALUE $ NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI# 3706/4(9 Air Conditioning: Unit Quantity / Tons Per Unit 3 REQUIRED Heat: Unit Quantity i BTU's Per Unit 8ori-u-1 Seer Rating /3• o Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks(gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct All prn sions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority o violate the provision j ofy other state or local law regulation construction or the performance of construction. Property Owners Name '� V ��I Phone Number Mechanical Companyrro�•� Office PhonZ -Q, Co. Address: M City State Zip to License Holder(Print): ��� C State Certification/Registration Notarized Signature of License Holder - idSworn and scribed before me this da of �Q/7 Kd K/I 20/,3 KAREN E.PANTFOEDER NOTARY PUBLIC Signature of rotary Public STATE OF FLORIDA Comm#EE064448 Expires 3/4/2015 ru OWN • , www.ahridirectory.org certificate of Ptoduct Ratings AHRI Certified Reference Number: 3700149 Date: 1/16/2013 Product: Split System: Heat Pump with Rete Outdoor Unit-Air-Source Outdoor Unit Model Number: 213BN(A,W)0361*A Indoor Unit Model Number: FB4CNF036 Manufacturer: BRYANT HEATING AND COOLING SYSTEMS Trade/Brand name: LEGACY LINE PURON IIIP Manufacturer responsible for the rating of tils system combination is BRYANT HEATING AND COOLING SYSTEMS Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity(Btuh): 000 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh)@ 47 F: 34000 Region IV HSPF Rating (Heating): 8.00 Heating Capacity(Btuh)@ 17 F: 21400 i .Rabrigsfollowed by an asterisk(')indicate a voluntary rerate of prev-opublished data,unless accompanied with a WAS;which indicates an involuntary rerate. DISCZ71MER AHRI does not endorse the produc4s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclairrs all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at t�ry.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database:or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at Air-Conditioning,Heating, click on" "link and enter the AHRI Certified Reference Number and the date on + _' and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. 02012 Air-Conditioning,Heating, and Refrigeration Institute CERTIFICATE NO.: 130028427568837677 4; I Project SummaJob: Sluzevich Summary I � � •� Date: 1/16/2013 Entire House By: AL Pr•'ect Information For: Aaron Sluzevich, Tropic Heating&Air Conditioning, Inc. 331 2 nd St.,Atla itic Beach, FL 32233 Phone: 904-241-'788 Fax: 904-241-2172 Email: Tropicac@msn.com Notes: Des!•n Information Weather: Jacksonville/Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD 35 °F Design TD 16 °F Daily range M Relative humidity 50 % Moisture difference 53 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 23812 Btuh Structure 17984 Btuh Ducts 5056 Btuh Ducts 6866 Btuh Central vent(0 cfm) 0 Bt h Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 28868 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 24850 Btuh Method SimlAified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1920 Btuh Ducts 1192 Btuh Heating ing Central vent(0 cfm) 0 Btuh Prea(ft2) 1200 1200 Equipment latent load 3112 Btuh Volume(ft) 9600 9600 Air changes/hour 0.45 0.23 Equipment total load 27962 Btuh Equiv.AVF(cfm) 72 37 Req. total capacity at 0.70 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make Trade n/a Trade Model n/a Cond AHRI ref n/a Coil AHRI ref Efficiency n/a Efficiency 0 SEER Heating input 0 MBtuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 1138 cfm Actual air flow 1138 cfm Air flow factor 0.039 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.89 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. fill.�- ' 2013-Jan-1612:40:33 Wtt tltSOft, Right-Sude®Universal201212.1.05 Right JMobile Pagel -' C:\W NDOWS\TEMPlwstrnpG5160f426-ee02-41bd-a86f-60072f05fdd9.rup Calc=MJ8 Front Door faoes. S RiRight J® Mobile Report Job: Sluzevich 9 P Date: 1/16/2013 Entire House By: Her.. s'W aft 5.►tr-r6 AL Project • ! For: Aaron Sluzevich, Tr pic Heating&Air Conditioning, Inc. 3312 nd St.,Atlanti Beach, FL 32233 Phone: 904-241-17 Fax: 904-241-2172 Email:Tropicac@m n.com Design • • • Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature(°F) 70 75 Elevation: 43 ft Design TD(°F) 35 16 Latitude: 30'N Relative humidity(%) 30 50 Outdoor: Heating C ling Moisture difference(gr/Ib) 8.4 52.8 Dry bul b(°F) 35 91 Infiltration: Daily range(°F) - 17 ( M ) Method Simplified Wat bulb('F) - 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Component Btuh/ft2 Btuh %of load Walls 7.5 8004 27.7 MIS Glazing 19.7 2432 8.4 V1WIs Doors 13.5 425 1.5 Ceilings 2.6 3072 10.6 I�, , Floors 6.0 7142 24.7 -- Infiltration 2.3 2736 9.5 Ducts 5056 17.5 waft Piping 0 0 ata Humidification 0 0 �Ilr>gs Rcas Ventilation 0 0 Adjustments 0 Total 28868 100.0 Cooling Component Btu h/ft2 Btuh %of load Walls 3.5 3724 15.0 WAIS Interral Gins Glazing 41.9 5173 20.8 Doors 11.4 360 1.4 Ceilings 3.3 3978 16.0 Floors 0 0 0 Infiltration 0.5 659 2.7 Ducts 6866 27.6 Ventilation 0 0 p Internal gains 4090 16.5 }. Blower 0 0 Ctha ' Adjustments 0 Ceilirw Irfilhalicn Total 24850 100.0 Latent Cooling Load=3112 Btuh Overall U-value=0.168 Btuh/ft2-'F Data entries checked. 2013-Jan-16 12:40:33 Wf�gtllSClt Right-Su de® bil Universal201212.1.05 Right J®Moe Pagel - C:\WINDOWS\TEMP\wstmp\5160f426-ee02-41bd-a86f-60072fO5fdd9.rup Calc=MJ8 FrontDoorfaces: S Right-J® Worksheet Job: Sluzevich Entire House Date: 1/16/2013 ;I.r.:,q cf..., By: AL 1 Room name Entire House First Floor 2 Exposed wall 152.0 ft 152.0 ft 3 Room height 8.0 ft d 8.0 ft heaticool 4 Room dimensions 1.0 x 1200.0 ft 5 Room area 1200.0 ft' 1200.0 ft' Ty Construction U-value Or HTM Area (f t') Load Area (ft') Load number (Btu h/ft1-°F) ( (Btuh/ft2 or perimeter (ft) (Btu h) or perimeter (ft) (Btu h) Heat C1 Gross N/P/S Heat Cool Gross N/P/S Heat Cool 614E-2 0.218 n 7.54 3.51 320 256 1931 899 320 256 1931 899 1D-c2ow 0 570 n 19.72 20.91 33 0 641 680 33 0 641 680 11D0 0.390 n 13.49 11.43 32 32 425 360 32 32 425 360 V� 14E-2 0.218 e 7.54 3.51 288 259 1952 908 288 259 1952 908 11 L--, 1D-c2ow 0.570 e 1972. 63.01 29 0 575 1838 29 0 575 1838 V� 14E-2 0.218 s 7.54 3.51 320 288 2169 1009 320 288 2169 1009 L—(, 1 D-c2ow 0.570 s 19.72 25.16 33 0 641 818 33 0 641 818 V� 14E-2 0.218 w 7.54 3.51 288 259 1952 908 288 259 1952 908 1 1D-c2ow 0.570 w 1972. .01 29 0 575 1838 29 0 575 1838 C 17A-10xd 0.074 2.56 3.32 1200 1200 3072 3978 1200 1200 3072 3978 F 22A-cph 1.358 - 46.99 0.00 1200 152 7142 0 1200 152 7142 0 61 c)AED excursion 1 0 0 Envelope loss/gain 1 21076 13235 1 1 21076 13235 12 a) Infiltration 2736 659 2736 659 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 3 690 3 690 Applianceslother 3400 3400 Subtotal(lines 6 to 13) 23812 17984 23812 17984 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 23812 17984 23812 17984 15 Duct loads 21% 38% 5056 6866 21% 38% 5056 6866 Total room load 288681 248501 288681 24850 Air required(cfm) 11381 11381 11381 1138 Calculations approved ACCA to meet all re uirements of Manual J 8th Ed. wrighFsafT. 2013-Jan-1612:40:33 Right-Suite®Universal 2012 2.1.05 Right J®Mobile Page 1 C.\VNNDOWStTEMPlwstmp\5160f426-ee02-41bd-a86f-60072f0 fdd9.rup Calc=MJ8 FrontDoorfaces. S Component Constructions Job: Sluzevich P Date: 1/16/2013 �w Entire House By: X11`C""sus AL Projectf For: Aaron Sluzevich,Tr pic Heating&Air Conditioning, Inc. 3312 nd St.,Atlantic'Beach, FL 32233 Phone: 904-241-1788 Fax: 904-241-2172 Email:Tropicac@msn.com Design • • • Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature(°F) 70 75 Elevation: 43 ft Design TD(OF) 35 16 Latitude: WON Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(grAb) 8.4 52.8 Dry bulb(°F) 35 91 Infiltration: Daily range(°F) - 17 ( M ) Method Simplified Wet bulb(T) - 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Construction descriptions or Area U-value Insul R Htg HTM Loss Clg HTM Gain fF BlutifF-'F ff'-°FfBUh Bkb/W BNh BbhRF BWh Walls 14E-2:Blk wall,r-2 ext bd ins,8"thk n 256 0.218 2.0 7.54 1931 3.51 899 e 259 0.218 2.0 7.54 1952 3.51 908 s 288 0.218 2.0 7.54 2169 3.51 1009 w 259 0.218 2.0 7.54 1952 3.51 908 all 1061 0.218 2.0 7.54 8004 3.51 3724 Partitions (none) Windows 1 D-c2ow:2 glazing,cir outr,air gas,wd frm mat,dr innr,114"�p, n 33 0.570 0 19.7 641 20.9 680 1/8"thk a 29 0.570 0 19.7 575 63.0 1838 s 33 0.570 0 19.7 641 25.2 818 w 29 0-570 0 19.7 575 63.0 1838 all 123 0.570 0 19.7 2432 41.9 5173 Doors 11 D0:Door,wd sc type n 32 0.390 0 13.5 425 11.4 360 Ceilings 17A-10xd:Flat ceiling,tar and gravel roof mat,wd deck,r-10 deck 1200 0.074 10.0 2.56 3072 3.32 3978 ins,1/2"gypsum board int fish,1.5"thkns Floors �sh 22A cph:Bg floor,heavy damp soil,on grade depth,carpet flr 152 1.358 0 47.0 7142 0 0 ht:SOFt 2013-Jan-1612:40:34 Wrl 9 Right-Sude®UnN Universal Pagel C:XWNDOWMTEMPIwsbW%516Df426-ee02-41bd-a86f4WO72Kd9.rup Calc=MJ8 Front Door faces: S AED Assessme t Job: Sluzevich I Date: 1/16/2013 Entire House By: aa�w•!sYttrrt AL Project • • For: Aaron Sluzevich, Tropic Heating&Air Conditioning, Inc. 331 2 nd St.,Atlantic Beach, FL 32233 Phone: 904-241-178Fax: 904-241-2172 Email:Tropicac@ms .com Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature(°F) 70 75 Elevation: 43 It Design TD(°F) 35 16 Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 8.4 52.8 Dry bul b(°F) 35 91 Infiltration: Da i ly range (T) - 17 ( M ) V\Ietbulb(°F) - 77 Wind speed(mph) 15.0 7.5 i Test for s • Exposure Diversity HourlyGlazing Load 7100 6700c- 5100c- 41 00 ,005,004100 3700C 2100c- UN- 8 1001 ,008 9 10 11 12 13 14 15 16 17 18 19 20 Flour of Day HoWy / Aeraage AEDliait Maximum hourly glazing load excee s average by 19.1%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh W r 1 htsoft 2013Jan-1612:40:34 9 Right-,,,e, Right J®Mobile Pagel - C:\WINDOWS\TEMP\wstmp\5160F426-ee02-41bd-a86f-60072f05fdd9.rup Calc=MJ8 FrontDoorfaces. S