Permit HVAC 386 2nd St 2013 CITY OF ATLANTIC BEACH j 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00002224 Date 2/26/13 Property Address . . . . . . 386 2ND ST Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ ROSS, XAVIER & JILL J & W HEATING AND AIR 902 THOMPSON DRIVE 11232 ST.JOHNS IND PKWY STE 4 BAYSHORE NY 11706 JACKSONVILLE FL 32246 (904) 764-0040 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . REPLACE CU/AHU Permit Fee . . . . 99 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 8/25/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 99 . 00 99 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 103 . 00 103 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITU OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 n Ph (904 247-5826 Fax (904) 247-5845 .�4 .TOB ADDRESS: �< �/V/ pl �. c3 PERMIT# !�• a�- PROJECT VALUE $ NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTA ATI 1 ARI Air Conditioning: Unit Quantity l Tons Per Unit RE IED Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the per rmance of construction Property Owners Nam Phone Numbe) t Mechanical Com an —� Y Office Phone gib Fax Uz1 Co. Addressl Cityy 1 [�t Stat �,�Zip-522 License Holder(Print): 5 � aY"I er StateRj Certification/Registration#l` $ %�111111')Vol Notarized Sign\ �� , ,lFf0v.Holder n `oi�' SSS°201p�9FSworn and subscribed before me this �— da of T< l` a f-c 20 I3 X. �.� o='Signature of Notary Public Ll 11111111{11� CERTIFIEDT" F , Certificate of Product Ratings AHRI Certified Reference Number: 3699488 Date: 2/26/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 25HBC336(A,W)**30 Indoor Unit Model Number: FB4CNF036 Manufacturer: CARRIER AIR CONDITIONING Trade/Brand name: COMFORT 13 PURON HP Manufacturer responsible for the rating of this system combination is CARRIER AIR CONDITIONING Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 34000 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh) @ 47 F: 34000 Region IV HSPF Rating (Heating): 8.00 Heating Capacity(Btuh) @ 17 F: 21400 Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION ��, The information for the model cited on this certificate can be verified at www.ahridirectory.ory, Air-Conditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on &'%a �■ `' which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. and Refrigeration Institute ©2012 Air-Conditioning,Heating, and Refrigeration Institute CERTIFICATE NO.: 130063771404529088 Location: 9 Street Address > 2nd . t, Atlantic Beach, F1_ 3223 r...atitude, Longi1."Lid e 30.3375 �, -81,7686" Nouse SquareFootage: 1544 s(;i. ft, Phone: Ernai1: Kd SNS, 3 Number of residents 2 Ceiling height 0 Wall U-v lue mvaluE� Floor- U-value -value 0.2 5 Ceiling U-Value R,..valuc 0.053 1 Window U-value 0.5 Window SHGF 0. 33 Moisture grains 53 Duct lass °f 10 Duct gain % 10 Cooling infiltraction (ACH) 0.6 Heating infiltration (ACH) 0.8 Winter ventilation 0 Surnmer ventilation 0 • IL ! Outdoor Heating Cooling Dry bulb (`F) 32 93 Daily range 1114 Relative humidity 50% Moisture difference 5:3 Indoor Heating Cooling Indoor teen ,erature ('T) 70 7 Design temperature di f'er nceff) 38 18 Area Btuh % of load Nall 4079 14. Floor 7395 25,9 Ceiling 3110 10. Windows 4218 14.7 Infiltration 7203 25.2 yst rn Efficiency Loss 2600 `A Total: 2860 Heating Loads 28,604 BTLI/h /r System Efficiency Loss Floor Ceiling i _.... Wall Infiltration Windows Area Btuh % of load 'VV a I I 1 ,21 Ceiling 3110 9,7 Latent Infiltration 46 ,��, Internal 17 3 2 5A Sensible People Load 460 Latenit: People Load rip 1All, Total: 32122 Sensible load 27005 I._ratten't I o a d 5"1"1", SHR 0,84 Capacity at .75 SHR 100 T( ns Cooling Loads 32—'22 RTJ�hr Sensible People Load Latent People Load ( /_......._. .... Internal f..=- Wall Sensible Infiltration Windows —System Efficient, Ceiling Latent Infiltration US AED Graph 30000 20000 ..._.._. 10000 '- ��`' - - �.►���_ Sam 9am loam 11am 2pm 1pm 2pm Spm 4pm 5pm 6pm 7pm Spm Hourly Loads —Average System equipment selection will be rnade using the following derived values, Summer Outdoor 93"F Summer Wet Bulb "F Summer Indoor 75"F Summer Desigr'i Grair1S 50% Winter Outdoor 32"F Winter Indoor 70':F Sensible Crawling 27,005 Btuh Latent Cooling 5, 18 I: tuh Required Coaling Airflow 1,227 CFM Sensible Heating 28,604, B'r:Ijh Required Heating Air-flow 371. CFM All calculations are based upon approved hvac industry star ands and pioc=edures,and con"iply with all local, state and federal code retluirernen&All€omput d rix?sul(s ,;,reg E.,tim,ates,Product by Energy Design Syst{ams andIL9r:,',a3 Tree