Loading...
333 2ND ST - ENERGY NEW HOME FORM 405-10 FILL COPY FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2ND STREET Builder Name: OSSI HOMES Street 2ND STREET Permit Office: ATLANTIC BEACH/Z City,State,Zip: ATLANTIC BEACH , FL,32266 Permit Number: /S`- S F2 - Owner Jurisdiction: 261100 Design Location: FL, MAYPORT_NS 1. New construction or existing New(From Plans) 9. Wall Types(3846.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Frame Wood, Exterior R=19.0 3846.70 ft2 b. N/A R= ft2 3. Number of units,if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 5 d. N/A R= ft2 10.Ceiling Types (2216.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic(Vented) R=30.0 2216.00 ft2 6. Conditioned floor area above grade(ft2) 4304 b. N/A R= ft2 c. N/A R= ft2 Conditioned floor area below grade(ft2) 0 11. Ducts R ft2 7. Windows(528.0 sqft.) Description Area a.Sup: 1st Floor, Ret: 1st Floor,AH: 1st Floor 6 430.4 a. U-Factor: Dbl, U=0.47 528.00 ft2 b.Sup: 2nd Floor, Ret:2nd Floor,AH:2nd Floor 6 430.4 SHGC: SHGC=0.35 b. U-Factor N/A ft2 12.Cooling systems kBtu/hr Efficiency a.Central Unit 36.0 SEER:15.00 SHGC: b.Central Unit 36.0 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 36.0 HSPF:7.70 SHGC: b. Electric Heat Pump 36.0 HSPF:7.70 Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.350 14. Hot water systems a. Electric Cap:60 gallons 8. Floor Types (4304.0 sqft.) Insulation Area EF:0.940 a. Floor Over Other Space R=19.0 2088.00 ft2 b. Conservation features b.Slab-On-Grade Edge Insulation R=0.0 2088.00 ft2 None c.other(see details) R= 128.00 ft2 15. Credits Pstat Total Proposed Modified Loads: 50.05 PASS Glass/Floor Area: 0.123 Total Standard Reference Loads: 81.70 I hereby certify that the plans and specifications covered by Review of the plans and ..a°•�'F1E Sri,;••.•• this calculation are in compliance with the Florida Energy specifications covered by this �'ti�,"',aL;=''?FO� Code. ) ��u E Z_ calculation indicates compliance �.F� ,, '; with the Florida Energy Code. �. , :_ ,,i �. PREPARED B_Y: 'u Before construction is completed 1 td` "" '• x _ g'g '„ y �' B(,�>I•DATE: _ r5/) / this building will be inspected for : V i c s.a compliance with Section 553.908 . - y�� • Florida Statutes. i 4"(.f I hereby certify that t h i s .. din., as d: itned, is in compliance tiCOD W-,4Jy with the Florida Energ Code CO OWNER/AGENT: �� `- __ BUILDING OFFICIAL: iii ()''- DATE: ----_ ...OMPEIF#t DATE: - 6-1/-/5- - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist 5/18/2015 7:10 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5 PROJECT Title: 2ND STREET Bedrooms: 5 Address Type: Street Address Building Type: User Conditioned Area: 4304 Lot# Owner: Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: OSSI HOMES Rotate Angle: 0 Street: 2ND STREET Permit Office: ATLANTIC BEACH Cross Ventilation: County: Duval Jurisdiction: 261100 Whole House Fan: City,State,Zip: ATLANTIC BEACH, Family Type: Single-family FL, 32266 New/Existing: New(From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,MAYPORT_NS FL_MAYPORT_NS 2 39 90 70 75 1037 61 Medium BLOCKS Number Name Area Volume 1 Blockl 2088 20880 2 Block2 2216 22160 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 1st Floor 2088 20880 Yes 2 1 1 Yes Yes Yes 2 2nd Floor 2216 22160 No 2 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge lnsulatio 1st Floor 189.3 ft 0 2088 ft2 ____ 0 0 1 2 Floor Over Other Space 2nd Floor ____ ____ 2088 ft2 19 0 0 1 3 Raised Floor 2nd Floor ____ ____ 128 ft2 19 0 0 1 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2478 ft2 0 ft2 Medium 0.96 No 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 2216 ft2 N N 5/18/2015 7:10 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5 CEILING V # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic(Vented) 2nd Floor 30 2216 ft2 0.11 Wood WALLS V/ Adjacent Space Cavity Width Height Sheathing Framing Solar Below Y # Ornt To Wall Type p R-Valiia Ft In. Ft In Area R-V21ue Fraction AhgoL Grade o 1 N Exterior Frame-Wood 1st Floor 19 35 10 350.0 ft2 0.23 0.75 0 _ 2 E Exterior Frame-Wood 1st Floor 19 59 8 10 596.7 ft2 0.23 0.75 0 3 S Exterior Frame-Wood 1st Floor 19 35 10 350.0 ft2 0.23 0.75 0 4 W Exterior Frame-Wood 1st Floor 19 59 8 10 596.7 ft2 0.23 0.75 0 5 N Exterior Frame-Wood 2nd Floor 19 35 10 350.0 ft2 0.23 0.75 0 6 E Exterior Frame-Wood 2nd Floor 19 63 2 10 631.7 ft2 0.23 0.75 0 7 S Exterior Frame-Wood 2nd Floor 19 35 10 350.0 ft2 0.23 0.75 0 8 W Exterior Frame-Wood 2nd Floor 19 62 2 10 621.7 ft2 0.23 0.75 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 Wood 1st Floor None .2 .1 .1 .1 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Double Yes 0.47 0.35 48.0 ft2 2 ft 0 in 2 ft 0 in Drapes/blinds Exterior 5 2 N 1 Vinyl Low-E Double Yes 0.47 0.35 36.0 ft2 2 ft 0 in 2 ft 0 in Drapes/blinds Exterior 5 3 E 2 Vinyl Low-E Double Yes 0.47 0.35 108.0 ft2 2 ft 0 in 2 ft 0 in Drapes/blinds Exterior 5 4 S 3 Vinyl Low-E Double Yes 0.47 0.35 36.0 ft2 2 ft 0 in 2 ft 0 in Drapes/blinds Exterior 5 5 W 4 Vinyl Low-E Double Yes 0.47 0.35 36.0 ft2 2 ft 0 in 2 ft 0 in Drapes/blinds Exterior 5 6 N 5 Vinyl Low-E Double Yes 0.47 0.35 12.0 ft2 2 ft 0 in 2 ft 0 in Drapes/blinds Exterior 5 7 N 5 Vinyl Low-E Double Yes 0.47 0.35 60.0 ft2 2 ft 0 in 2 ft 0 in Drapes/blinds Exterior 5 8 E 6 Vinyl Low-E Double Yes 0.47 0.35 75.0 ft2 2 ft 0 in 2 ft 0 in Drapes/blinds Exterior 5 9 S 7 Vinyl Low-E Double Yes 0.47 0.35 3.0 ft2 2 ft 0 in 2 ft 0 in Drapes/blinds Exterior 5 10 S 7 Vinyl Low-E Double Yes 0.47 0.35 45.0 ft2 2 ft 0 in 2 ft 0 in Drapes/blinds Exterior 5 11 S 7 Vinyl Low-E Double Yes 0.47 0.35 24.0 ft2 2 ft 0 in 2 ft 0 in Drapes/blinds Exterior 5 12 W 8 Vinyl Low-E Double Yes 0.47 0.35 45.0 ft2 2 ft 0 in 2 ft 0 in Drapes/blinds Exterior 5 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Best Guess .0005 5644.7 309.89 582.79 .474 7.869 5/18/2015 7:10 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:7.7 36 kBtu/hr 1 sys#1 2 Electric Heat Pump None HSPF:7.7 36 kBtu/hr 2 sys#2 COOLING SYSTEM __V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER: 15 36 kBtu/hr 1080 cfm 0.75 1 sys#1 2 Central Unit None SEER: 15 36 kBtu/hr 1080 cfm 0.75 2 sys#2 HOT WATER SYSTEM V _ # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None 1st Floor 0.94 60 gal 80 gal 120 deg None SOLAR HOT WATER SYSTEM V FSEC Collector Storage Cert If Company Name System Model If Collector Model# Area Volume FEF None None ft2 DUCTS V ----Supply--- Return Air CFM 25 CFM25 HVAC# # Location R Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 1st Floor 6 430.4 ft 1st Floor 107.6 ft Default Leakage 1st Floor (Default) (Default) 1 1 2 2nd Floor 6 430.4 ft 2nd Floor 107.6 ft Default Leakage 2nd Floor (Default) (Default) 2 2 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Ceoaoltn g [X JJaan n XFeb b X] Maar r Apr My X Juun n X JJuul X Aug Au X Se f Occt t Xl Nov ix, Dec Venting [ Jan Feb X]Mar A pr l Ma [ Jun Jul 'Aug t Se p 1X Oct lX Nov 1 :Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 5/18/2015 7:10 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: 2ND STREET PERMIT#: ATLANTIC BEACH, FL, 32266 MANDATORY REQUIREMENTS SUMMARY -See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC-rated as meeting ASTM E 283. Windows and doors= 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: .,—■ gasketed doors& outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat& 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced-air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to= R-2 - +accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent l to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of= 1 &Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor-retardant covers or a liquid cover or other means proven to reduce heat loss except if 70%of heat from site-recovered energy. Off/timer switch required. Gas heaters minimum _' thermal efficiency=78% (82%after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat>10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. _� 5/18/2015 7:10 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 61 The lower the EnergyPerformance Index, the more efficient the home. 2ND STREET, ATLANTIC BEACH, FL, 32266 0 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Frame Wood, Exterior R=19.0 3846.70 ft2 b. N/A R= ft2 II 3. Number of units,if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 5 d. N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? No a. Under Attic(Vented) R=30.0 2216.00 ft2 6. Conditioned floor area(ft2) 4304 b. N/A R= ft2 7. Windows" Description Area c. N/A R= ft2 11. Ducts R ft2 a. U-Factor: Dbl, U=0.47 528.00 ft2 a. Sup: 1st Floor, Ret: 1st Floor,AH: 1st Floor 6 430.4 SHGC: SHGC=0.35 b.Sup: 2nd Floor, Ret:2nd Floor,AH:2nd Floor 6 430.4 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor N/A ft2 a.Central Unit 36.0 SEER:15.00 SHGC: b.Central Unit 36.0 SEER:15.00 d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 36.0 HSPF:7.70 Area Weighted Average Overhang Depth: 2.000 ft. b. Electric Heat Pump 36.0 HSPF:7.70 Area Weighted Average SHGC: 0.350 8. Floor Types Insulation Area 14. Hot water systems Cap:60 gallons a. Floor Over Other Space R=19.0 2088.00 ft2 a. Electric EF:0.94 b.Slab-On-Grade Edge Insulation R=0.0 2088.00 ff2 c.other(see details) R= 128.00 ft2 b. Conservation features None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building ° "°. ,PP F'CHT4i,'., Construction through the above energy say. g features which will be installed (or exceeded) moo, ,, _ _ Fo ,'w in this home before final inspe Other, ise, a new EPL Display Card will be completed `�� ' �' based on installed Code coy pliant eaturl ` '-4 •°`' °o.', •Builder Signature: _ Date: 1(/,'5;-'. , /, ; /„� ' c�*1-.. .Q_--- ',,..1./ \Iri /'Address of New Home: /3 5 Z- • p� S'71- City/FL Zip: � in j,Z � �i l4 �'b °� S`, •c06�wE.7�4 FL_ .3 z 2 33 '. *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Project Summary Job: Y M Date: May y 15,2015 FIRST FLOOR By: ERIN RODRIGUEZ Ili Pro'ect Information For: 2ND STREET 2ND STREET, ATLANTIC BEACH, FL 32266 Notes: NEW CONSTRUCTION Desi• n Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 92 °F Inside db 68 °F Inside db 74 °F Design TD 29 °F Design TD 18 °F Daily range L Relative humidity 50 % Moisture difference 60 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 16215 Btuh Structure 15453 Btuh Ducts 6407 Btuh Ducts 8898 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 22621 Btuh Use manufacturer's data n Rate/swing multiplier 0.97 Infiltration Equipment sensible load 23621 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2165 Btuh Ducts 2231 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 2088 2088 Equipment latent load 4396 Btuh Volume (ft') 20883 20883 Air changes/hour 0.28 0.15 Equipment total load 28018 Btuh Equiv. AVF (cfm) 99 53 Req. total capacity at 0.70 SHR 2.8 ton Heating Equipment Summary Cooling Equipment Summary Make Bryant Make Bryant Trade LEGACY LINE PURON HP Trade LEGACY LINE PURON HP Model 215BNA036****A Cond 215BNA036****A AHRI ref Coil FX4DN(B,F)037 AHRI ref Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 24360 Btuh Heating output 34600 Btuh @ 47°F Latent cooling 10440 Btuh Temperature rise 27 °F Total cooling 34800 Btuh Actual air flow 1160 cfm Actual air flow 1160 cfm Air flow factor 0.051 cfm/Btuh Air flow factor 0.048 cfm/Btuh Static pressure 0.03 in H2O Static pressure 0.03 in H2O Space thermostat Load sensible heat ratio 0.85 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2015-May-17 23:05:29 wrightsoft Right-Suitee Universal 2012 12.1.08 RSU01508 Page 1 ightsoft HVAC\Template\OSSI-2ND STREET AB rup Calc=MJ8 Front Door faces. N Project Summary Job: Y M Date: May y 15,2015 SECOND FLOOR By: ERIN RODRIGUEZ For: 2ND STREET 2ND STREET, ATLANTIC BEACH, FL 32266 Notes: NEW CONSTRUCTION Desi• n Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 92 °F Inside db 68 °F Inside db 74 °F Design TD 29 °F Design TD 18 °F Daily range L Relative humidity 50 % Moisture difference 60 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 13707 Btuh Structure 15880 Btuh Ducts 6601 Btuh Ducts 9168 Btuh Central vent (0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 20308 Btuh Use manufacturer's data n Rate/swing multiplier 0.97 Infiltration Equipment sensible load 24296 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2245 Btuh Ducts 2302 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area(ft2) 2216 2216 Equipment latent load 4547 Btuh Volume (ft3) 22161 22161 Air changes/hour 0.28 0.15 Equipment total load 28844 Btuh Equiv. AVF (cfm) 102 55 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Bryant Make Bryant Trade LEGACY LINE PURON HP Trade LEGACY LINE PURON HP Model 215BNA036****A Cond 215BNA036****A AHRI ref Coil FX4DN(B,F)037 AHRI ref Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 24360 Btuh Heating output 34600 Btuh @ 47°F Latent cooling 10440 Btuh Temperature rise 27 °F Total cooling 34800 Btuh Actual air flow 1160 cfm Actual air flow 1160 cfm Air flow factor 0.057 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0.03 in H2O Static pressure 0.03 in H2O Space thermostat Load sensible heat ratio 0.85 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ± wri Fitsoft 2015-May-172305:e9 9 Right-Suite®Universal 2012 12.1.08 RSU01508 Page 2 ightsoft HVAC\Template\OSSI-2ND STREET AB rup Calc=MJ8 Front Door faces: N Duct System Summary Job: May 1 y Summary Date: May 15,2015 FIRST FLOOR By: ERIN RODRIGUEZ For: 2ND STREET 2ND STREET, ATLANTIC BEACH, FL 32266 Heating Cooling External static pressure 0.03 in H2O 0.03 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.03 in H2O 0.03 in H2O Supply/return available pressure 0.02/0.01 in H2O 0.02/0.01 in H2O Lowest friction rate 0.012 in/100ft 0.012 in/100ft Actual air flow 1160 cfm 1160 cfm Total effective length (TEL) 247 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk BATH h 523 29 14 0.019 5.0 Ox 0 VIFx 14.8 110.0 st4 DINING c 3816 151 170 0.015 12.0 Ox 0 VIFx 28.7 130.0 st4 FAMILY c 2982 72 133 0.014 10.0 Ox 0 VIFx 40.1 130.0 st3 FAMILY-A c 2981 72 133 0.013 10.0 Ox 0 VIFx 38.6 150.0 st3 FAMILY-B c 2981 72 133 0.012 10.0 Ox 0 VIFx 41.6 155.0 st3 KITCHEN c 3281 100 146 0.017 10.0 Ox 0 VIFx 13.9 130.0 st4 LIVING h 3480 191 135 0.019 12.0 Ox 0 VIFx 34.0 90.0 st3 LIVING-A h 3480 191 135 0.019 12.0 Ox 0 VIFx 15.9 110.0 st3 OFFICE h 2527 139 93 0.022 10.0 Ox 0 VIFx 20.6 90.0 st4 STAIR/HALL h 2605 143 69 0.015 11.0 Ox 0 VIFx 5.5 150.0 st4 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st3 Peak AVF 599 668 0.012 253 22.0 0 x 0 VinIFIx st4 Peak AVF 561 492 0.015 257 20.0 0 x 0 VinIFIx Bold/italic values have been manually overridden �' wrightsoft 2015-May-18064015 9 Right-Suite®Universal 2012 12 RSU01508 Page 1 _ightsoft HVAC\Template\OSSI-2ND STREET AB.nip Cale=MJ8 Front Door faces N I Return Branch Detail Table Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb1 Ox0 1160 1160 50.6 0.012 315 26.0 Ox 0 VIFx 2015-May-18 06:40:15 +i+ wrightsoft Right-Suite®Universal 2012 12.1.08 RSU01508 Page 2 ightsoft HVAC\Template\OSSI-2ND STREET AB rup Calc=MJ8 Front Door faces N Duct System Summary Job: May 1 Y Summary Date: May 15,2015 SECOND FLOOR By: ERIN RODRIGUEZ Project Information For: 2ND STREET 2ND STREET,ATLANTIC BEACH, FL 32266 ttd1t" u x,_.is 3 .,a ,“, ... niFyr.:7_.:ar 1;...h<. s r.: W r ',A kY,.il;'v.; !% n1 0-7, :_^r; Return Branch Detail Table Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb2 Ox 0 1160 1160 44.0 0.013 315 26.0 Ox 0 VIFx wrightsoft Right-Suttee Universal 201212.1.O8RSU01508 201SMay-1806:40:15 Page ACCT ...ightsoft HVACITemplate\OSSI-2ND STREET AB.rup Calc=MJ8 Front Door faces: N TABLE 402A.2 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: 2ND STREET Builder Name: OSSI HOMES Street: 2ND STREET Permit Office: ATLANTIC BEACH City,State,Zip: ATLANTIC BEACH, FL,32266 Permit Number: Owner: Jurisdiction: 261100 Design Location: FL, MAYPORT_NS COMPONENT CRITERIA CHECK Air barrier and thermal barrier Exterior thermal envelope insulation for framed walls is installed in substantial contact and continuous alignment with building envelope air barrier. Breaks or joints in the air barrier are filled or repaired. Air-permeable insulation is not used as a sealing material. Air-permeable insulation is inside of an air barrier. Ceiling/attic Air barrier in any dropped ceiling/soffit is substantially aligned with insulation and any gaps are sealed. Attic access (except unvented attic), knee wall door, or drop down stair is sealed. Walls Corners and headers are insulated. Junction of foundation and sill plate is sealed. Windows and doors Space between window/door jambs and framing is sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including Insulation is installed to maintain permanent contact with underside above-garage and cantilevered of subfloor decking. floors) Air barrier is installed at any exposed edge of insulation. Crawl space walls Insulation is permanently attached to walls. Exposed earth in unvented crawl spaces is covered with Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, knee walls and flue shafts opening to exterior or unconditioned space are sealed. Narrow cavities Batts in narrow cavities are cut to fit, or narrow cavities are filled by sprayed/blown insulation. Garage separation Air sealing is provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures are air tight, IC rated, and sealed to drywall. Exception—fixtures in conditioned space. Plumbing and wiring Insulation is placed between outside and pipes. Batt insulation is cut to fit around wiring and plumbing, or sprayed/blown insulation extends behind piping and wiring. Shower/tub on exterior wall Showers and tubs on exterior walls have insulation and an air barrier /' separating them from the exterior wall. Electrical/phone box on Air barrier extends behind boxes or air sealed-type boxes are installed. Common wall Air barrier is installed in common wall between dwelling units. HVAC register boots HVAC register boots that penetrate building envelope are sealed to subfloor or drywall. -----Fireplace _ Fireplace walls include an air barrier. ' EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Load Short Form Jo 51515 V.S.J May Entire House 9 L g tc 'I 1 i I ERIN RODRIGUEZ FILE COPY JUN 10 .. „ Project InformatiutI For: 2ND STREET 2ND STREET,ATLANTIC BEACH, FL 32266 Design Information Htg Clg Infiltration Outside db(°F) 39 92 Method Simplified Inside db(°F) 68 74 Construction quality Average Design TD(°F) 29 18 Fireplaces 0 Daily range - L Inside humidity(%) 30 50 Moisture difference(gr/lb) 2 60 HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref. n/a Coil n/a AHRI ref. n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) SECOND FLOOR d 2145 20481 24665 1160 1160 FIRST FLOOR d 2091 21094 26031 1160 1160 Entire House d 4236 41575 50696 2320 2320 Other equip loads 0 0 Equip. @ 0.97 RSM 49175 Latent cooling 8862 TOTALS I 4236 I 41575 I 58037 I 2320 1 2320 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ` - - wrightsoft Right Suite®Unersal 2015 RSU01508 2015-Jun-101 0:53 P age /CD% _.ghtsoft HVACVTemplate1OSSI-2ND STREET AB.rup Calc=MJ8 Front Door faces: N Job: 51515 o u uFz Load Multizone Summary Report Date: May 15,2015 enelryy c Orrs ti g By: ERIN RODRIGUEZ Infiltration Summary Heating Cooling ZONE NAME Volume ACH AVF HTM Volume ACH AVF HTM ft.' cfm Btuh/ft' fN cfm Btuh/ft' SECOND FLOOR 21447 0.29 103 1.2 21447 0.15 55 0.4 FIRST FLOOR 20910 0.27 95 1.2 20910 0.15 51 0.4 Entire House 42356 0.28 198 1.2 42356 0.15 106 0.4 Load and AVF Summary ROOM NAME Area Htg load ('Ig load I Itg AVE CIg AVF ft' Btuh Btuh cfm cfm WIC 103 648 596 37 28 STAIR 143 1616 2329 92 110 MASTER 458 3877 4999 220 235 MBATH 217 2223 2076 126 98 CLOSET 180 752 799 43 38 LOFT 166 898 1634 51 77 BEDROOM1 210 2475 2989 140 141 LAUNDRY 142 1146 1746 65 82 BEDROOM3 281 3608 3847 204 181 BEDROOM2 245 3238 3651 183 172 SECOND FLOOR 2145 20481 24665 1160 1160 LIVING 456 6961 6054 383 270 FAMILY 475 3926 8945 216 399 OFFICE 288 2527 2084 139 93 BATH 156 523 309 29 14 STAIR/HALL 310 2605 1542 143 69 KITCHEN 197 1815 3281 100 146 DINING 208 2737 3816 150 170 FIRST FLOOR 2091 21094 26031 1160 1160 Entire House 4236 41575 50696 2320 2320 2015-Jun-10 13:40:53 wrightsoft' Right-Suite®Universal 2015 15.0.17 RSU015O8 Page 1 ightsoft HVAC\Template\OSSI-2ND STREET AB rup Calc=MJ8 Front Door faces: N ' 51515 Loads for Multiple Orientations Job: May P 1 Date: May 15,2015 Entire House By: ERIN RODRIGUEZ Project Information For: 2ND STREET 2ND STREET,ATLANTIC BEACH, FL 32266 Design Conditions Location: Indoor: Heating Cooling Jacksonville Mayport Naval, FL, US Indoor temperature(°F) 68 74 Elevation: 16 ft Design TD(°F) 29 18 Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 2.4 60.3 Dry bulb(°F) 39 92 Infiltration: Daily range(°F) - 15 ( L ) VVet bulb(°F) - 78 Wind speed(mph) 15.0 7.5 r Front Door North Northeast East Southeast I South Southwest West Northwest Sensible Load(Btuh) 49175 49083 47398 50959 50237 52035 47398 49558 Latent Load(Btuh) 8862 8862 8862 8862 8862 8862 8862 8862 Total Load(Btuh) 58037 57946 56261 59821 59100 60897 56261 58420 Heating AVF(cfm) 2320 2320 2320 2320 2320 2320 2320 2320 Cooling AVF(cfm) 2320 2320 2320 2320 2320 2320 2320 2320 Building Orientation Coding Load ;ern •mmme Am 0 N NE E SE S SW W NW ❑rectiai Frcnt Ma faces Current Orientation: Front Door faces North Highest Cooling Load: Front Door faces Southwest Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2015-Jun-1013'40'53 wrightsoft Rig ht-Su Kee Universal 201515.0.17 RSU01508 Page 1 ACCP. ..ightsoft HVAC\Template\OSSI-2ND STREET AB.rup Cak=MJ8 Front Door faces: N • Job: 51515 R D I Ez Building Analysis Date: May 15,2015 ,� •` t C. •• �l[ik,r1 Entire House By: ERIN RODRIGUEZ Pro'ect Information For 2ND STREET 2ND STREET,ATLANTIC BEACH, FL 32266 Desi•n Conditions Location: Indoor: Heating Cooling Jacksonville Mayport Naval, FL, US Indoor temperature (°F) 68 74 Elevation: 16 ft Design TD(°F) 29 18 Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 2.4 60.3 Dry bulb(°F) 39 92 Infiltration: Dailyrange(°F) - 15 ( I ) Method Simplified V\kt bulb(°F) - 78 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Heatin• Component Btu h/ft2 Btuh %of load Walls 2.0 9576 23.0 Glazing 14.9 8049 19.4 Doors 0 0 0 Ceilings 0.9 2048 4.9 Floors 1.2 2630 6.3 Infiltration 1.2 6302 15.2 Ducts 12970 31.2 Piping 0 0 Humidification 0 0 Ventilation 0 0 II: Adjustments 0 Total 41575 100.0 • Coolin• Component Btuh/ft2 Btuh %of load Walls 1.5 7512 14.8 Va• Glazing 34.5 18634 36.8 Doors 0 0 0 Ceilings 1.8 3910 7.7 °m Floors 0.2 534 1.1 Infiltration 0.4 2095 4.1 Ducts 18011 35.5 Ventilation 0 0 Internal gains 0 0 m Blower 0 0 Adjustments 0 Total 50696 100.0 Latent Cooling Load=8862 Btuh Overall U-value=0.084 Btuh/ft2-°F Data entries checked. 4 wrightsoft Ri ht-Suite®Universal 2015 15 0 17 RSU01508 2015Jun-1013:405 1 ACCA g Page 1 ightsofi HVAC1TemplatelOSSI-2ND STREET AB rup Calc=MJB Front Door faces: N Component Constructions Job: 51515 P Date: May 15,2015 Entire House By: ERIN RODRIGUEZ Pro°ect Information For: 2ND STREET 2ND STREET,ATLANTIC BEACH, FL 32266 Design Conditions Location: Indoor: Heating Cooling Jacksonville Mayport Naval, FL, US Indoor temperature(°F) 68 74 Elevation: 16 ft Design TD(°F) 29 18 Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 2.4 60.3 Dry bulb(°F) 39 92 Infiltration: Daily range(°F) - 15 ( L ) Method Simplified V■kt bulb(°F) - 78 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain k Btuh/ft--°F 11.-°F/Btuh BhhAt' Btuh BWhM' Btuh Walls 12E-Osw:Frm wall,stucco ext,r-19 cav ins, 1/2"gypsum board int n 1051 0.068 19.0 1.97 2073 1.55 1626 fish,2"x6"wood frm,16"o.c.stud e 1300 0.068 19.0 1.97 2564 1.55 2011 s 1099 0.068 19.0 1.97 2168 1.55 1700 w 1405 0.068 19.0 1.97 2771 1.55 2174 all 4856 0.068 19.0 1.97 9576 1.55 7512 Partitions (none) Windows 10D-v:2 glazing,dr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, n 48 0.490 0 14.2 682 10.8 519 1/8"thk;2 ft overhang(8 ft window ht,2 ft sep.);6.67 ft head ht 1 D-c2ow:2 glazing,clr outr,air gas,wd frm mat,dr innr,1/4"gap,1/8" n 38 0.570 0 16.5 628 21.9 831 thk;2 ft overhang(6 ft window ht,2 ft sep.);6.67 ft head ht e 114 0.570 0 16.5 1884 64.0 7293 s 38 0.570 0 16.5 628 21.9 831 w 38 0.570 0 16.5 628 64.0 2431 all 228 0.570 0 16.5 3769 49.9 11387 4A5-2ov:2 glazing,dr low-e outr,air gas,vnl frm mat,dr innr,1/4"gap, n 12 0.470 0 13.6 164 14.9 179 1/8"thk,6.67 ft head ht 4A5-2ov:2 glazing,clr low-e outr,air gas,vnl frm mat,dr innr,1/4"gap, n 60 0.470 0 13.6 818 14.9 893 1/8"thk;2 ft overhang(5 ft window ht,2 ft sep.);6.67 ft head ht e 75 0.470 0 13.6 1022 38.2 2865 s 45 0.470 0 13.6 613 14.9 670 w 45 0.470 0 13.6 613 38-2 1719 all 225 0.470 0 13.6 3067 27.3 6147 4A5-2ov:2 glazing,dr low-e outr,air gas,vnl frm mat,dr innr,1/4"gap, s 3 0.470 0 13.6 41 14.9 45 1/8"thk;2 ft overhang(2 ft window ht,2 ft sep.);6.67 ft head ht 4A5-2ov:2 glazing,dr low-e outr,air gas,vnl frm mat,dr innr,1/4"gap, s 24 0.470 0 13.6 327 14.9 357 1/8"thk,2 ft overhang(6 ft window ht,2 ft sep.);6.67 ft head ht Doors (none) wr htsoft 2015-Jun-10 13'40:55 Right-Suite® RSU01508 P 1 ACC . ightsoft HVAC\Template\OSSI-2ND STREET AB.rup Cale=MJ8 Front Door faces. N Ceilings 16B-30ad:Attic ceiling,asphalt shingles roof mat,r-30 cell ins,1/2" 2207 0.032 30.0 0.93 2048 1.77 3910 gypsum board int fnsh Floors 19C-19cscp:Fir floor,frm flr,6"thkns,carpet flr fnsh,r-2 ext ins,r-19 1628 0.049 30.0 0.49 802 0.31 498 cav ins,tight crwl ovr,r-11 wall insul 120 0.049 30.0 0.49 59 0.31 37 all 1748 0.049 30.0 0.49 861 0.31 534 22A-tpl:Bg floor,light dry soil,on grade depth 62 0.989 0 28.7 1769 0 0 it 2015-Jun-1013:40:55 wrightsoftt Right-Suite&Universal 2015150.17 RSU01508 Page 2 AUCK ...ightsoft HVAC1Template\OSSI-2ND STREET AB.rup Calc=MJ8 Front Door faces: N Project Summary M Job: May 1 Date: May 15,2015 FIRST FLOOR By ERIN RODRIGUEZ Pro-ect Information For: 2ND STREET 2ND STREET,ATLANTIC BEACH, FL 32266 Notes: NEW CONSTRUCTION Desi•n Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 92 °F Inside db 68 °F Inside db 74 °F Design TD 29 °F Design TD 18 °F Daily range L Relative humidity 50 % Moisture difference 60 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 14685 Btuh Structure 17129 Btuh Ducts 6409 Btuh Ducts 8901 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 21094 Btuh Use manufacturer's data n Rate/swing multiplier 0.97 Infiltration Equipment sensible load 25250 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2084 Btuh Ducts 2237 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 2091 2091 Equipment latent load 4321 Btuh Volume(ft3) 20910 20910 Air changes/hour 0.27 0.15 Equipment total load 29571 Btuh Equiv.AVF(cfm) 95 51 Req.total capacity at 0.70 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make Bryant Make Bryant Trade LEGACY LINE PURON HP Trade LEGACY LINE PURON HP Model 215BNA036****A Cond 215BNA036****A AHRI ref Coil FX4DN(B,F)037 AHRI ref Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 24360 Btuh Heating output 34600 Btuh @ 47°F Latent cooling 10440 Btuh Temperature rise 27 °F Total cooling 34800 Btuh Actual air flow 1160 cfm Actual air flow 1160 cfm Air flow factor 0.055 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.03 in H2O Static pressure 0.03 in H2O Space thermostat Load sensible heat ratio 0.86 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrL.�.tSOi'C 2015Jun-1013.4228 Right-Suite®Universal 2015 15.0.17 RSU01508 Page 1 ACCN ightsoft HVAC\Template\oSSI-2ND STREET AB.nip Calc=MJ8 Front Door faces. N • Project Summary Job: May 1 •7 Date: May 15,2015 SECOND FLOOR By: ERIN RODRIGUEZ Pro"ect Information For: 2ND STREET 2ND STREET,ATLANTIC BEACH, FL 32266 Notes: NEW CONSTRUCTION Desi.n Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 92 °F Inside db 68 °F Inside db 74 °F Design TD 29 °F Design TD 18 °F Daily range L Relative humidity 50 % Moisture difference 60 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 13920 Btuh Structure 15556 Btuh Ducts 6561 Btuh Ducts 9109 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 20481 Btuh Use manufacturer's data n Rate/swing multiplier 0.97 Infiltration Equipment sensible load 23925 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2256 Btuh Ducts 2285 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 2145 2145 Equipment latent load 4541 Btuh Volume(ft3) 21447 21447 Air changes/hour 0.29 0.15 Equipment total load 28466 Btuh Equiv.AVF(cfm) 103 55 Req.total capacity at 0.70 SHR 2.8 ton Heating Equipment Summary Cooling Equipment Summary Make Bryant Make Bryant Trade LEGACY LINE PURON HP Trade LEGACY LINE PURON HP Model 215BNA036****A Cond 215BNA036****A AHRI ref Coil FX4DN(B,F)037 AHRI ref Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 24360 Btuh Heating output 34600 Btuh @ 47°F Latent cooling 10440 Btuh Temperature rise 27 °F Total cooling 34800 Btuh Actual air flow 1160 cfm Actual air flow 1160 cfm Air flow factor 0.057 cfm/Btuh Air flow factor 0.047 cfm/Btuh Static pressure 0.03 in H2O Static pressure 0.03 in H2O Space thermostat Load sensible heat ratio 0.84 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 1 W rightSOR 2015-Jun-10 13:42:28 'r' RN• Right-Suite® RSU01508 Page 2 /ACA ...ightsoft HVAC\Template\OSSI-2ND STREET AB.rup Calc=MJ8 Front Door faces N G EZ AED Assessment Job: 51515 �� � Date: May 15,2015 erte7gy COnSt.iiiirlq Entire House By: ERIN RODRIGUEZ Project Information For: 2ND STREET 2ND STREET,ATLANTIC BEACH, FL 32266 Design Conditions Location: Indoor: Heating Cooling Jacksonville Mayport Naval, FL, US Indoor temperature(°F) 68 74 Elevation: 16 ft Design TD(°F) 29 18 Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 2.4 60.3 Dry bulb(°F) 39 92 Infiltration: Daily range(°F) - 15 ( L ) 1/tt bulb(°F) - 78 Wind speed(mph) 15.0 7.5 Test for Adequate Exposure Diversity Hourly Glazing Load 24,1$I 22,111 2:),II, �/ tam -----N■ 14,611 1qus am all. 411. 2110 0 I I I I I I - I 8 9 10 11 12 13 14 15 16 17 18 19 20 l-t d Dai Hourly Average AED nma Maximum hourly glazing load exceeds average by 9.2%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh 2015 Jun-10 13 40 55 1 Wrightsoft Right-Suite®Universal 2015 15.0.17 RSU01508 Page 1 /Fik ...ightsoft HVAC\Template\OSSI-2ND STREET AB.rup Cale=MJ8 Front Door faces: N r OR:GUEZ Right-J® Worksheet Job: 51515 1� �: st Entire House Date: May 15,2015 By: ERIN RODRIGUEZ 1 Room name Entire House SECOND FLOOR 2 Exposed wall 5396 ft 280.5 ft 3 Room height 10.0 ft d 10.0 ft d 4 Room dimensions 5 Room area 4235.6 f t' 2144.7 f t' 1 T Ty Construction U-value Or HTM Area (f l') Load Area (ft') Load number (Bt uh/ll'-'FT I (Bt uh/ft') I or perimeter (ft) (Btuh) I or perimeter (ft) I (Btuh) II Heat I Cool Gross N/P/S Heat I Cool I Gross I N/P/S I Heat Cool 1 6 VI 12E-Osw 0.068 n 1.97 1.55 1209 1051 2073 1626 511 439 865 6791 -C 100-v 0 490 n 1421 10.82 48 0 682 519 0 0 0 0 -C 1D-c2ow 0 570 n 16.53 21.88 38 0 628 831 0 0 0 0 -C 4A5-2ov 0 470 n 1363 1489 12 0 164 179 12 0 164 179 11 -C 4A5-2ov 0 470 n 13.63 14.89 60 0 818 893 60 0 818 893 VI 12E-Osw 0 068 e 1.97 1 55 1489 1300 2564 2011 892 817 1610 1263 -G 1D-c2ow 0 570 e 16.53 63 97 114 0 1884 7293 0 0 0 0 -G 4A5-2ov 0 470 e 13.63 38 19 75 0 1022 2865 75 0 1022 2865 VI 12E-Osw 0.068 s 1.97 1.55 1209 1099 2168 1700 511 439 865 679 -C 10-c2ow 0570 s 16.53 2188 38 38 628 831 0 0 0 0 -G 4A5-2ov 0.470 s 13.63 14 89 3 3 41 45 3 3 41 45 -G 4A5-2ov 0.470 s 13.63 14 89 45 45 613 670 45 45 613 670 -G 4A5-2ov 0.470 s 1363 14 89 24 24 327 357 24 24 327 357 VI 12E-Osw 0068 w 1.97 1.55 1488 1405 2771 2174 892 847 1670 1310 -G 1D-c2ow 0 570 w 16.53 63.97 38 0 628 2431 0 0 0 0 -C 4A5-2ov 0.470 w 13.63 38.19 45 0 613 1719 45 0 613 1719 C 16B30ad 0.032 - 0.93 1.77 2207 2207 2048 3910 2129 2129 1976 3771 F 19C-19cscp 0 049 - 0.49 0.31 1628 1628 802 498 0 0 0 0 F 19C-19cscp 0.049 - 0 49 0.31 120 120 59 37 120 120 59 37 F 22A-tol 0 989 - 28 68 0.00 456 62 1769 0 0 0 0 0 6 c)AED excursion I I Ir I 0 I I If 0 Envelope loss/ga 223031+ 305901 10644 144661 12 a) Infiltration 6302 2095 3276 1089 b) Room ventilation 0 0 0 0 13 Internal gains Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 610 13) 28605 32685 13920 15556 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 28605 32685 13920 15556 15 Duct loads 45% 55% 12970 18011 47% 59% 6561 9109 I I AAir re u rf ed(cfm) I I 423201 523 I 201 2048101 241616605 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 41- wrighttsoft ,� 2015-Jun-1013.4055 � )Univ ersal 2015 15.0 17 RSU01508 Page 1 ..ightsoft HVAC\Template\OSSI-2ND STREET AB.rup Calc=MJ8 Front Door faces. N 9 �' I,' r �), Right-J® Worksheet Job: 51515 ' d Date: May l � -44',.; - ;-; Entire House y,s,2015 By: ERIN RODRIGUEZ 1 Room name FIRST FLOOR 2 Exposed wall 259.1 ft 3 Room height 10 0 ft d 4 Room dimensions 5 Room area 2091 0 f l' I I t Ty Construction U-value Or HTM , Area (f I') Load Area Load r number I (Btuh/ft'-`FI I (Btuhift') I or perimeter (ft) `II (Btuh) I or perimeter I Heat Cool Gross I N/P/S Heat I Cool 1 Gross I N/P/S 1 Heat I fff Cool 6 W 12E-Osw 0.068 n 1.97 1.55 698 612 1208 947 -G 100-v 0.490 n 14.21 10.82 48 0 682 519 -G 1 D-c2ow 0.570 n 16.53 21.88 38 0 628 831 -(' 4A5-2ov 0.470 n 13.63 14.89 0 0 0 0 11 -G 4A5-2ov 0.470 n 13 63 14.89 0 0 0 0 VI 12E-Osw 0.068 e 197 1.55 598 483 953 748 -G 1 D c2ow 0.570 e 16.53 63 97 114 0 1884 7293 -C 4A5-2ov 0.470 e 1363 3819 0 0 0 0 W 12E-Osw 0.068 s 1.97 1.55 698 660 1302 1022 -G 1 D-c2ow 0.570 s 16 53 21.88 38 38 628 831 -G 4A5-2ov 0.470 s 1363 14.89 0 0 0 0 ---(' 4A5-2ov 0.470 s 13.63 14.89 0 0 0 0 -t3 4A5-2ov 0.470 s 13.63 14.89 0 0 0 0 VI 12E-0sw 0.068 w 197 1.55 597 559 1102 864 -G 1D-c2ow 0.570 w 16 53 63.97 38 0 628 2431 -G 4A5-20v 0 470 w 13 63 38.19 0 0 0 0 C 16B30ad 0.032 - 0.93 1.77 78 78 73 138 F 19C-19cscp 0.049 - 0.49 0.31 1628 1628 802 498 F 19C-19cscp 0.049 - 0.49 0.31 0 0 0 0 F 22A-tot 0.989 - 28.68 0.00 456 62 1769 0 6 c)AED excursion Envelope loss gain 1 1 116591 161230 1 1 I 1 1 12 a) Infiltration 3026 1006 b) Room ventilation 0 0 13 Internal gains Occupants @ 230 0 0 Appliances/other 0 Subtotal(lines 6 to 13) 14685 17129 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 14685 17129 15 Duct loads 44% 52% 6409 8901 Total room load 21094 1160 26031 1160 1 Air required(cfm) 1 ( 1 1 1 1 1 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -4,+- wrightsoft 2015-Jun-10134055 Right-Suite®Univ er sal 2015 15 0.17 RSU01508 11C- - ightsoft HVAC1Template\OSSI-2ND STREET AB rup Calc=MJ8 Front Door faces N Page 2