353 2ND ST - CONVERT DUPLEX TO SINGLE FAMILY 11APJ:r el r '' ssi CITY OF ATLANTIC BEACH - 800 SEMINOLE ROAD - 1sirATLANTIC BEACH, FL 32233 ;3 >V INSPECTION PHONE LINE 247-5814 RESIDENTIAL - NEW SINGLE FAMILY RESIDENCE MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: RES17-0244 Description: convert duplex to single family home &front porch addition Estimated Value: 151994.4 Issue Date: 12/20/2017 Expiration Date: 6/18/2018 PROPERTY ADDRESS: Address: 353 355 2ND ST RE Number: 169786 0000 PROPERTY OWNER: Name: JOHNSON JOANN Address: 181 PROCTORS PURCHASE RD HARTLY, DE 19953 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: THE DANTZLER GROUP Address: 5465 VERNA BLVD QA JOEL AMOS DANTZLER, JR JACKSONVILLE, FL 32205 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. s___ City of Atlantic Beach ��� APPLICATION NUMBER �3 Building Department (To be assigned by the Building Department.) 800 Seminole Road !- 2_ tK,,,,,,., ..,� Atlantic Beach, Florida 32233-5445 r eS 1 1 lo -k-(4 Phone (904)247-5826 • Fax(904)247-5845 �..ton10- 10 3 1 E-mail: building-dept@coab.us Date routed: i II - City web-site: http://www.coab.us L,_, 1117 APPLICATION REVIEW AND TRACKING FORM Property Address: 3 s a (---q- Sa . Department review required Yes No :Lidding_ Applicant: - NL 'pan-1-.J./ cubtke fanning & Zoning Tree Administrator Project: cOt\024A ail 0li x00Sl rip .664; Public Works �J ublic Utilities r''N�•I &Dn* )D(CAA Q.4,i^V6n Public Safety Fire Services Review fee $ 2c— Dept Signature 1=-14..— Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: PlApproved. ['Denied. [—Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: 1-4 4-N-----Date:(//z-( --- —Date:(// f 7 TREE ADMIN. Second Review: Approved as revised. Denied. pp � ❑Not applicable P ORKS� Comments: UBLIC UTILITIES //- Z - l7 PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: Approved as revised. ['Denied. ['Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 440 to `f- /9b '--4d`oD 1/pe ‘76.1-x-1 � � a„ _ Xb iaa Mdirk hipA, 441 f< 1,41% ' Nt-'x 9 uz iv /S16 \ dC. Aa ' jile 3 u a /� iP7a (Afx(AMII '1110°,4-4 /4 32b, 324 /74 q, 6r CHAPTER 4: BEST MANAGEMENT PRACTICES FOR EROSION AND SEDIMENTATION CONTROL FILTER FABRIC MATERIAL SPACING OF POSTS TO BE 6-10 FEET APART IA U i C@Yl ..... -m 11 is NI- 'T..hist^-1*----�...... I til §5 Int-- .. ... 2 FEET (MIM -- t FOR ADDITI❑NAL STRENGTH. ` FILTER FABRIC MATERIAL CAN t Iu 0 BACKFILLED TRENCH BE ATTACHED TO A 6-INCH (MAX) "--7111.-111I III- _ MESH VIRE SCREEN VHICH HAS '-1 I4_11 BEEN FASTENED TO THE POSTS I i 1 FIREILTER TORIAL�OF ID ATTACHING TWO SILT FENCESTI-E I AWPRarriATELY El IND-ES CF FILTER WOO OR I FABRIC r14TERIPL ItJST EXTDCRAZEThE Ern POST 1 STEEL POST CF-1)-£SECCNO FE10E \ vITH CEM3ACTED 860ff1 TERIPL - ----- ri,EETIFIRSTD RS 1 i 4-F • 1 � {NATE 93TH POSTS AT 1 Ui=U-'-I' -0�11� Ila - LEAST 110 OFIF�T5 N A dI�Irill I.r ,M.iWI.ak 1 OPezt-rGN TO 4 mla,� 4 g411 -y'' �-i APPF®@ATE 4-A'CN OPELTQ4 CF ara`F VATE3S 1-1 BY 4-D.04 TRET 1 l 1 l ' a bd Id I I I CET&EIOTT�1 POSTS ABMT f— i 1B rs PITO , caro Aro euz.TY£SAP 4 4 4 4 I Figure 4.4b. Installing a Filter Fabric Silt Fence Source HydroDynamics, Inc. ,; s=���r City of Atlantic Beach ��,APPLICATION NUMBER 41 Building Department _,^r-- (To be assigned bythe BuildingDepartment.) ==-W 800 Seminole Road t � _ Atlantic Beach, Florida 32233-5445 cs�� 0Z•44 y„ ~ uv iPhone(904)247-5826 • Fax(904) 247. 01 Lu'/ '!,01119- E-mail: building-dept@coab.us Date routed: WI at I0- City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 3 s ' (-4- S} . Department review required Yes No :uildin. Applicant: 7 h,t. ` en-1 -1A ( Cl ().tefanning'&Zoning") Tree Administrator Project: COr10)--1k d.u.Pit y AO ¶ (1N�j—�Q k Public Works V ublic Utilities h.wv..2. l 4 O11k QO(CAf 04(11-Wn Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: 1'pproved. 1 IDenied. Not applicable (Circle one.) Comments: BUILDING C . PLANNING &ZONING Reviewed b : , ,iA./ - / , Date: i -- r -i Prii -i TREE ADMIN. Second Review: Approved as revised. Denied. pp I lNot applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: Approved as revised. Denied. I 'Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 r`Ly:or, �' IA Comp. By: SRW r r Date: 10/4/2017 J "failly-z: Public Works Department City of Atlantic Beach Permit No: Address: 353 2nd Street Required Storage Volume Criteria: Section 24-66 of the City of Atlantic Beach's Zoning,Subdivsion, and Land Development Regulations requires that the difference between the pre-and postdevelopment volume of stormwawter runoff be stored on site. Volume of Runoff is defined as follows: V=CAR/12 Where: V=Volume of Runoff C=Coefficient of Runoff A=Area of lot in square feet R=25-yr/24-hr rainfall depth(9.3-inches for Atlantic Beach) Predevelopment Runoff Volume: Lot Area(A) = 10,500 ft2 Runoff Coefficient Area Lot Area Description (ft2) (ft) "C" Wtd "C" Impervious 1,872 10,500 1.00 0.18 Pervious 8,628 10,500 0.20 0.16 Runoff Coefficient(C)= 0.34 Runoff Volume V= 0.34 x 10,500 x 9.3 / 12 V= 2,788 ft3 Postdevelopment Runoff Volume: Lot Area(A) = 10,500 ft2 Runoff Coefficient Area Lot Area Description (ft2) (ft) "C" Wtd "C" Impervious 2,878 10,500 1.00 0.27 %ISA = 27.4% Pervious 7,622 10,500 0.20 0.15 Runoff Coefficient(C)= 0.42 Runoff Volume V= 0.42 x 10,500 x 9.3 / 12 V= 3,412 ft3 Required Storage Volume DV= Postdevelopment Runoff Volume-Predevelopment Runoff Volume DV= 3,412 - 2,788 DV= 624 ft3 Retention MASTER WATER RETENTION 10/4/2017 �sr- tifilith Comp. By: SRW -A-151 Date: 10/4/2017 yi �s !, Public Works Department City of Atlantic Beach Permit No: Address: 353 2nd Street Provided Storage: Elevation Area Storage (ft) (ft2) (ft3) 8.5 256 0 BOTTOM 16 X 16 9.0 324 145 TOB 18 X 18 Elevation Area Storage (ft) (ft2) (ft3) 0 BOTTOM 0 TOB Elevation Area Storage (ft) (ft2) (ft3) 0 BOTTOM 0 TOB Inground storage=A`d"pf A=Area= 324.0 d=depth to ESHWT= 5.5 pf= pore factor= 0.3 Inground Storage= 534.6 ft3 Required Treatment Volume= 624 ft3 Supplied Treatment Volume= 680 ft3 Retention MASTER WATER RETENTION 10/4/2017 C-1 JJ 2. CITY OF ATLANTIC BEACH w..-‘ _4.–" ` 800 Seminole Road �` Atlantic Beach,Florida 32233 �Jsilc)f REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS Date 12. -7_ 11 Revision to Permit Corrections to Comments Permit# RC-..,S 17- C7 Z 4 11– Project Project Address 3 S^3 2,I S r A t-tht e 8,4. ,At Contractor/Contact Name T4 d4-1.)tz(4-" v '.-0�(( f"--C - AQ4 f/ � ,J� ,C. ' Phone 70r-7f' wia Email ;t om e e/4_,1z-hj-�0cr Ca;,,-7 Description of Proposed Revision/Corrections: Revision Review Fee Due$ $ ( 4 .2ov i/ frl L.?ff e,-- /,v i S/2c,ts 4 ct,„0,,1 Lc,uksy-_Say ftfr,w,) 1/-211; �� P44' MLet4 C.-4/ems w/41 Siff 6. s' A. 5u,lif j�Lir /e— 1-4C4-A01/ Additional Increase in Building Value $ • —( - Additional S.F. — ©— By signing below,I side" 4 U,¢N'2{s tib, affirm the Revision is inclusive of the proposed changes. (printed name) /2-- -?/7 Signatu'- •f • ,, or/• gent(Contractor must sign if increase in valuation) Date (Office Use Only) Approved / Denied Not Applicable to Department Revision/Plan Review Comments Department Review Required: Cluildini--) ,, --- i �� nnin &Zoning j Reviewed By Tree Administrator Public Works j � - 1 y _ ' Public Utilities Public Safety Date Fire Services 15i..:1 , City of Atlantic Beach APPLICATION NUMBER (s , Building Department (To be assigned bythe BuildingDepartment.) 'i.'-:, . ts� 9 p ) 800 Seminole Road _ - 1 ;, Atlantic Beach, Florida 32233-5445 r&s« 0 "'k44 Phone(904)247-5826 Fax(904) 247-5845 `� j;i 0. E-mail: building-dept@coab.us Date routed: at II City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 3 S a f>---O- Si- . Department review required Yes No :uilding Applicant: 7 \L 'fan- %-i-( El itkkP nn taing' Zoning& 11 Tree Administrator Project: ('Or10 Q--(k c a Oki y A n51t 4ais: Public Works ublic Utilities �OM I '4011-1/4- i)b(C-h Q.d.d,tibn Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. Denied. Not applicable (Circle one.) Comments: l q BUILDING �G�C L�X f'�0/,�(1 Ii� sL. t / ( Men t Se�AGL ES PLANNING &ZONING Reviewed by'---/ Date: 1 ( — '-- ( 7 TREE ADMIN. Second Review: A roved as revised. enied. ❑ pp /� ❑Not applicable PUBLIC WORKS Comments: / PUBLIC UTILITIES fir'ed, 19(6-11 letic(6 ks i �'4"te0 Si €1r15 PUBLIC SAFETY Reviewed by' j Date: / /-141 —17 FIRE SERVICES Third Review: Approved as revised. ❑Denied. Not applicable Comments: Reviewed by:��� Date: /1— 1''_ 7 Revised 05/19/2017 P- CITY OF ATLANTIC BEACH 800 Seminole Road ,% Atlantic Beach,Florida 32233 ik Telephone(904)247-5800 .-,:-,-...-....t-,,_,,,,4FAX(904)247-5845 �f .. REVISION REQUEST SHEET OR CORRECTIONS TO REVIEW COMMENT Date: ]) 113/17 Received by: Resubmitted: Permit er: p .-.5 / z C;a-/G/ cZiriop(,_.- Original Plans Examiner:6 r ) ke jr,c t5 Project Name: _ J1n- c't ( Project Address: 1-3 d''b 5-/. Contractor: ii, ;( l e2 - Contact N e: : , 7 teiZ Contact Phone : 9c;y 7Ft_3 -/0/r, Contact e-mail: i-+ i i- i t---1-(7--e)(9. c-,:,i. Revision/Plan Check/Permit Fee(s)Due: $ Description of Proposed Revision to Existing Permit: - (A_ e 1 S/- 5- t! r� . G cA (vivklocg./d/ a4ict Ig � //: . i� 1 (In -Cr- bp-V56 (oDe5 5er11- ,-11 e, hg- llvpi_ f1,.. r -- 5,(.:-cam- 1 ,.�,5/3,15 --f2 y)4- - k A. ,- „f ,f\ 5,4. 9)4.1 — 5, hp)d 7C — S - P6.-2,,, -5- 3z j.----"A-r)--) Additional Increase in Building Value: $ Additional S.F. Site Plan Revised: yej` Public W/U Approval: By signing below.I(print nae) mV n-47(tie— affirm that the above revision is inclusive of the •roposed ch: ges. 7 ,_. _ _ )l- /3—/ 7 Signature of Con .ctor/Agent( ontractor must sign if increase in valuation) Date Office Use Only Date: Approved: Rejected: / Notified by: Plan Review Comments: 5 /� �, + . k5 r I7(6- I VW1e0,`cr5 - : - ent review required Yes No >Build 1• lglannin &&Zoning f .) Tree AdminisTraFr / Plans Examiner Public Works 1 1-2e) t ? Public Utilities _ Public Safety Date Created 4/13/16 Rev 3 Fire Services { TREE & VEGETATION AFFIDAVIT ; iiir - City of Atlantic Beach • Department of Community Development t.), "• Planning&Zoning Division £1:310 800 Seminole Road Atlantic Beach, FL 32233 _ (P) 904 247-5800 (F) 904 247-5845 PERMIT# SECTION I-APPLICANT INFORMATION ;k/Owner(s) j— Legal Authorized Agent* NAME OF APPLICANT _ T %Qi 1/ D/9- L/ Q� NAME OF COMPANY br2e);419 --1,1 r ADDRESS OF COMPANY 51/G{ ! /Q�n n is/LAD 7T PHONE CiCy m /D/C) CELL / ,g37 07/*, EMAIL ' ,,e ( e 04,k6rivaer,01,4 CONTRACTOR CERTIFICATION NUMBER ATLBCH BUSINESS TAX RECEIPT NUMBER SECTION II-SITE INFORMATION STREET ADDRESS OF PROPERTY S5-3 " 54 If an address has not been assigned to this property,contact the AB Building Department at(904)247-5826 to request an address. LEGAL DESCRIPTION 6(i, r6 1.5- a?F ,_9c LOT gO BLOCK y SUBDIVISION (:) /0( 4'-h 4C B464 REAL ESTATE NUMBER 16 9 ni.6 __ �Cec LOT OR PARCEL SIZE: r%d��L)8 SQ FT AC RESIDENTIAL COMMERCIAL OTHER(SPECIFY) lgorrstfinimmommaammummunimm _ 1 affirm that I have reviewed the provisions of Chapter 23, "Protection of Trees and Native Vegetation"of the Municipal Code of Ordinances for the City of Atlantic Beach, FL and/or I have participated in a pre-application meeting with the Administrator of those regulations. Subsequently, I affirm that no regulated trees and no regulated vegetation will be damaged, destroyed and/or removed from the above-described or adjacent properties in conjunction with this project. SI:* 'RIPOFOW4• • SIGNATURE OF OWNER Signed and swo n before me on thista day of J'[ pm f , Z0) ,by State of 'f t I County of D\mil Identification verified: V n� Oath sworn: E Yes [� L No z :,:.'ue,c THOMAS L.ANDREWS III 1 (t/ * _(_� * MY COMMISSION#FF 106138 Notary gnature Ana_ EXPIRES:July 25,2018 'j4re0 F,,rf Bonded Thru Budget Notary Services My Commission expires: 3-i)ti ,� 101 9) r� �; City of Atlantic Beach OFFICE COPY APPLICATION NUMBER ,-91, Building Department (To be assigned by the Building Department.) �., 800 Seminole Road t_ _ - -F,? Atlantic Beach, Florida 32233-5445 r cs« 0Z-44 Phone(904)247-5826 • Fax(904)247-5845 t ` 3 ,f`j i T.O. E-mail: building-dept@coab.us Date routed: ` 10 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 3 s f=d- S4 , Department review required Yes No uildin� Applicant: T hL tan- % L( C� (1)61-e fanning &Zoning Tree Administrator Project: Corti o-ik dacml(1Vptl[ QM,� Public Works ublic Utilities *I.tstv^Q long Qorc,h adds-Wn Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. Rbenied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING & ZONING Reviewed by: i / Date: /1-6-/7 TREE ADMIN. Second Review: Approved as revised. enied. Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: ),--- Date: /1' 22 'f7 FIRE SERVICES Third Review: r p oved as revised. nDenied. ❑Not applicable Comments: Reviewed by: Date:JZ I ‘r 17 Revised 05/19/2017 Fax (904) 247-5845 3 a h '� c71, OFFICE COPY 11.22.2017 Second Review - i"----- Level3 Alterations. Review Section 907—Structural, in the 2014 5th Edition FBC- Existing Building. Determine if any improvements are needed at this time to existing structural components. Would recommend a continuous tie down system from roof framing to wall to sill plate/foundation at this time. Please verify and submit details on how this could be achieved. There was no detail of the anchoring of the 2 new LVL CEILING BEAMS. Please sub o it . • ails. �'tg' Mike Jones /2 - 7- !7 Building Inspector/Plan Reviewer illCity Of Atlantic Beach y 800 Seminole Road Atlantic Beach, FL 32233-5445 Ofc (904) 247-5844 e )/-eah el ielVilit, &fe4fs 1/-Z[ 1'7 M- 2 , t r =; pr,` CITY OF ATLANTIC BEACH ;_, �; s) 800 SEMINOLE ROAD j ATLANTIC BEACH, FL 32233 (904) 247-5800 BUILDING DEPARTMENT REVIEW COMMENTS Date: 11.06.2017 Permit#: RES17-0244 Site Address: 353 2" St. Site Address: 5465 Verna Blvd. Review: 1 Phone: 783-1010 RE#: 169786-0000 Email: rhett(a,dantzlergroup.com Homeowner: Joan Johnson, Applicant: The Dantzler Group, Inc. jjohnson99@hughes.net CORRECTION COMMENTS: 1. From the 2014 5th Edition of the FBC- Existing Building, Chapter 3, choose a method of compliance/alteration level. Place this information on page S1.5 of the structural pages under Design Codes. 2 copies please. You may be required to install smoke alarms if not already existing. 2. Page 1 of 4, of the energy forms needs to be signed and dated by the `owner/agent'. Both sets please. 3. The Energy Performance Level (EPL) Display Card needs to be filled out completely. Both sets please. 4. Submit the dimension of the existing roof distance from the house and what the total distance will be after the 4 foot extension. This may require plan review/approval from the Planning and Zoning Department, depending on the distance from new extension and the front yard setbacks. 5. Submit the ICC- ES Evaluation Reports for the spray foam insulation. 2 copies. Mike Jones Building Inspector/Plan Reviewer City Of Atlantic Beach 800 Seminole Road Atlantic Beach, FL 32233-5445 Ofc (904) 247-5844 1 1 a`lI r'1 �' ' `SSS CITY OF ATLANTIC BEACH r. 800 SEMINOLE ROAD � ixATLANTIC BEACH,FL 32233 �` ''- ___-0.1-119',- OFFICE coP . (904)247-5800 BUILDING DEPARTMENT REVIEW COMMENTS Date: 11.06.2017 Permit#: RES17-0244 Site Address: 353 2nd St. Site Address: 5465 Verna Blvd. Review: 1 Phone: 783-1010 RE#: 169786-0000 Email: rhett( dantzlergroup.com Homeowner: Joan Johnson, Applicant: The Dantzler Group,Inc. jjohnson99@hughes.net CORRECTION COMMENTS: 1 rom the 2014 5th Edition of the FBC- Existing Building, Chapter 3, choose a method of compliance/alteration level. Place this information on page S1.5 of the structural pages under Design Codes. 2 copies please. You may be re• . 'red to install smoke alarms if not already existing. R-e c-/%y .,� 2. ge • • • • .. ' • Li • s needs to , • • • • arm �'!1 the `owner/agent'. Both sets please. 3. The Energy Performance Level (EPL) Display Card needs to be filled o gee.. I, • . •1 . Bo 1 • , ease. 0 `/7 4 - •mi the dimension of the existing roof distance from the house and what the total distance will be after the 4 foot extension. This may require plan review/approval from the Planning and Zoning Department, depending o /2. //../ ;. • • • ' tance from new extension and the front yard setbacks. fr)..b . ubmit the ICC- ES va ua ion ' eports for the spray oam insulation. o •ies. (2-{(---- /1.4:0-? „ y Mike Jones Building Inspector/Plan Reviewer City Of Atlantic Beach 800 Seminole Road Atlantic Beach, FL 32233-5445 Ofc (904) 247-5844 atV) PV Com Yin.ew 4-1" 1 1- 6-/-7 my CITY OF ATLANTIC BEACH . a 800 Seminole Road Atlantic Beach,Florida 32233 REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS Date 12. -2- 1 7 Revision to Permit Corrections to Comments Permit# 1 G. S 17- V Z 44- Project 4- Project Address 3 c3 2,v-I S r A ri. l, - Contractor/Contact Name71( r - 7' Phone fO14-7n- la fa Email RA.47,lQ6:e6.0-7 Description of Proposed Revision/Corrections: Revision Review Fee Du• $ Ste. OCA $ ( 4 .] 02 � /7L 1X" �''5/ mss 7 f� tl 2��� h�si L�c�S�SCoI/ ��.�-gk/or) P "Jib,/ �1 r" ;;�i � 5�f6,145 s` o ,// h.:4 f d• ,�U�hjis�� 11c s/ Additional Increase in Building Value $ Additional S.F. —. — By signing below,I Jai/ * 04,,,-64,-c-- affirm the Revision is inclusive of the proposed changes. (printed name) / /7 Signatu•- •f • or/: gent(Contractor must sign if increase in valuation) Date (Office Use Only) Approved ?(‘ Denied Not Applicable to Department Revision/Plan Review Comments Department Review Required: uilding� /11 anninq &Zoning Reviewed By Tree Administrator Public Works Public Utilities / '/ Y'/ 7 Public Safety Date Fire Services .' ' ,,�� CITY OF ATLANTIC BEACH .-/ . '='\ 800 Seminole Road Atlantic Beach,Florida 32233 s) Telephone(904)247-5800 " ' " FAX(904)247-5845 l '-01319'' REVISION REQUEST SHEET OR CORRECTIONS TO REVIEW COMMENT i Date: ]1 /3/(7 r r Received by: Resubmitted: Permit r: l-1e 5 / z,;©?L/t( (� Original Plans Examiner:6 r )'k.e �`jr,c)e3 Project Name: , {)r) l Kar-)oD Ec/ Project Address: c3 d''D 54. Contractor: i ;r l 2 ,12.0 , �, . Contact • e: : • 7(e. i Contact Phone : qc,y 7 fit.3 -/Qin Con •- -m•' �J-fMy(• . c.. Revision/PIan Check/Permit Fee(s)Due: $ 50.QC Description of Proposed Revision to Existing Permit: }� 1 `' (7) -4.110) - 4, On — "'t S I- c :Lr-vblee i 401 e "/: 4e /eve" /# r n eX 1.10-45(7 co0es Ser-/- 'rl, cjr n � y "5 e--e 5 J/v') 47- E Pt. 'n,se, (,a, z ` 3 Tc e );,-r-)4.." /0'1.5 -H-2004", 1 A „1 \ 5,: 1:3�\ - 5. 3014 ;Tr - b 5 Q s -Y Additional Increase in Building Value: $ Additional S.F. -- Site Plan Revised: yeS Public W/U Approval: ' , • By signing below.I(print name) �t49'i" S--)0,4--(14?tur?_ affirm that the above revision is inclusive of the rroposed ch: ges. Signature of Con •ctor/Agent( ontractor must sign if increase in valuation) Date Office Usc Only Dale: // 2/"1 ` Approved: Rejected: x Notified by Plan Review Comments: �1 EI'r ,4ed o?nel Rot/i-e . r Co, rM 0•4./h 0 Co„ COT , i A5 L-PVP/ 3 4' (.rgi', v1.r' i - ! - ent review required n'tYes/ No .. -Build' • V _ Ph9&Zoning Plans Examiner t ree Administrator Public Works M ii -2-/-r7 Public Utilities — Public Safety Fire Services Date . 013J16 Rev.3 i I OFFICE COPY -�� �„ Building Permit Application — ,,._ , r City of Atlantic Beach OCT 3 �� V 800 Seminole Road,Atlantic Beach, FL 32233 X017 Phone:(904)247-5826 Fax: (904)247-5845 Dt C. ` t ' n>> r� SII"—Oa�U Job Address: S�2 � .� `j-).. Permit Number: Legal Description "7-CA to;15 -.-24 E .95/ 6,7 ,ao L: (/21-e rig {111, RE# 16`/JS' c=oc Valuation of Work(Replacement Cost)$ Il/• 171 Heated/Cooled SF /.2y L, Non-Heated/Cooled I,)C • Class of Work(Circle one): New Addition Alteration Repair Move Demo Pool Window/Door • Use of existing/proposed structure(s)(Circle one): Commercial esidentiaJ • If an existing structure,is a fire sprinkler system installed?(Circle one): Yes N/A • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: j e J0 t E3,06 •- En-ti t2 e, 1 &a;lve>2t t Jr.c lam• 4- u,7�/c'. r,-;:'1 1 i Florida Product Approval# J " for multiple products use product approval form Property Owner Information Name: �z.,An r) ' ,ht)-5 .1 Address: 3-5-3 ,;' 34- city j }-Iprn4-w &— .L State T / Zip 32 z.--.1 ? Phone E-Mail h1.--1,30i1 ci'i C/I' )4,_)j1-e.51 i) -} Owner or Agent(If Agent,Power of Attorney or Agency Letter Required) Contractor Information /% Name of Company: 2 !.J((��J�+n .4,,.4,, 2 1 ,5 nt• . Qualifying Agent: Address Y/(. 5" eQ nA f J t7 City •S/k,„/ 5,,,,i.7,//-- State !! Zip , ;?.7,f1,j' Office Phone cfc y n1-; ft,/U Job Site/contact Number Vt 7 XI i c,/ State Certification/Registration if i�17L-4(�.7`11 E-Mall f •4--i'f� \,)4,04-7l,;z 4,-,,,,,. t: . ,--0,-.,-1 Architect Name&Phone a Engineer's Name&Phone q /' c .,' 3 t ri e-$z, 16E7 a6n 3(a C/o Workers Compensation (.7•A .S c,,_ t 1-,,at C..n�- c1////e _ Exe /Insurer/ ase Emploveesl'Expiration to Application is hereby made to obtain a permit to do the work and Installations as indicated.I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction.I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS, WELLS,POOLS,FURNACES,BOILERS,HEATERS,TANKS,and AIR CONDITIONERS,etc. OWNER'S AFFIDAVIT:I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR TICE OF COMMENCEMENT. --'? __Levi-- ell'il/ ' 1.11111".. (Signature of Owner or Agent including Contractor) . ;n. e of Contractor) Siig.ned andlsworn to(or affirmed)before me this/Olay of Signed and sworn to(or affirmed)before me thi?5" day of 06(5/-454 ,c)-0/q .by Jomanrl•••TO//i%t I6ch s _,_.QJ ,by tea r _ Signature of Notary) (Sign ure ofi`{�j ►,SL•PJ't t FF 1061 GLENDA ANN WILLIAMS ''pV PUBS,' ,„CON\SS'DN 2018 Notary Public r> y MVEXp�RES•..IUi'Nmrysec t* State of Delaware * ��° dtproBA9 My � �� go e reqi(ts On h4(Personally Known OR '`',•leOFFs' PF A±!' Vii, .... :QA:.A., I I Produced Identification Type of Identification: b/<l(-It'''. LI c-e/Lse Type of Identification: REVISION / —?C''1 BP# Res/7- 02-W LUCASS SCOT1ENGINEERINGINC DATE /2 / /Y / /7 12627 San Jose Boulevard,Suite 603•Jacksonville,Florida 32223 SIGNED ri l dv Douglas V.Lucas,P.E. Licensed in FL Office(904)260-2690 Fax(904)260-2671 doug@Lucas-Scott.com November 28, 2017 City of Atlantic Beach OFFICE COPY Building Department 800 Seminole Road Atlantic Beach, Florida 32233 Re: Johnson Residence,353 2nd Street, Atlantic Beach, Florida, Engineering Job No. 170502, Permit No. RES17-0244, Plan Review Comments 2 To Whom It May Concern: 1. This project is a Florida Building Code 2014, Existing, Alteration Level 3. The existing exterior walls are CMU block. The existing rafters shall be tied to the plate w/(1) H2.5a clip. 2. The LVL ceiling beams shall be attached to interior walls w/(2) MSTA24 straps and to exterior masonry walls w/(1) H2.5a clip. The engineering changes to the subject project are structurally satisfactory. If you require any additional information, please do not hesitate to contact me. Sincerely, Douglas V. Lucas, P.E. Structural Engineer totIIIi ,`� Iri,,,� v• 1), ag9 .�c �. • d' •w_ • • 114,FS S;pN `` �� • OFFICE COPY 4,405 4.2 ?ids,‘.. 353-355 2ND ST,ATLANTIC BEACH FL BUILT 1948 N 36-0" 1' PORCH LIVING ROOM B LIVING ROOM A KITCHEN B KITCHEN A M • BEDROOM A BEDROOM B s.b fy R7 r OFFICE COPY , PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACHFLORIDA Project Name: -5e,hn,-)r r' ap rr,cDG I Permit # R8 /7- 4019c/ � Project Address: 3.5ha 3 �4. ,440k &.gc_ L.. f As required by Florida Statute 553.842 and Florida Administrative Code Rule 9B-72,please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide roduct approval may be obtained at: www.floridabuildin/.or.. Category/Subcategory Manufacturer Product Description Limitation of Use State# Local # A.EXTERIOR DOORS ,11A a4 1 . 1. Swinging Utz'"0- 1 S,4- CPQ-Pi in,--99. /.... 2. Sliding 1 3. Sectional t 4.Roll up t 5. Automatic 1 6. Other B.WINDOWS 1. Single hung 2.Horizontal slider 3. Casement 4.Double hung P, i y I p .,e , 5.Fixed 6.Awning 6 7. Pass-through 8.Projected 9.Mullion 10.Wind breaker 11. Dual action r 12. Other Category/Subcategory Manufacturer Product Description imitation of Use State# Local# C.PANEL WALL 1. Siding -3Ae5 -{- N=9.e [4,a-7S7,P —i4 1,'3L 9,• T +�n 2. Soffits - _L. — 3. EIFS 4. Storefronts L. T 5. Curtain walls 6.Wall louvers i 7. Glass block t 8. Membrane 9. Greenhouse 10. Synthetic stucco 11. Other D. ROOFING PRODUCTS 1.Asphalt shingles r...,--15�,X f, D .101,�� RI r1__. __ _�, 2. Underlayments "Z1),no • ) I �r, o ',01 ` /-5" 3. Roofing fasteners 4.Nonstructural metal roof I 5. Built-up roofing F 6. Modified bitumen I 7. Single ply roofing 8. Roofing tiles 9. Roofing insulation 4 t 10.Waterproofing 11.Wood shingles/shakes 12. Roofing slate 13. Liquid applied roofing 14. Cement-adhesive coats 15. Roof tile adhesive 16. Spray applied polyurethane roof 1 17. Other Category/Subcategory Manufacturer Product Description imitation of Use State# Local# .. . _ _ E. SHUTTERS ulaii 1.Accordion 2. Bahama 3. Storm panels 4. Colonial 5. Roll-upIIIIIIM 6. Equipment 7. Other F. STRUCTURAL I COMPONENTS j. uG'Wu 0A,Je c `'/7N. 1.Wood connector/anchor i yu;Ito .5o.- 4 (-j4iyu z 7 5 2. Truss plates 3. Engineered lumber ,ZVL I l6 p . 4.Railing i 5. Coolers-freezers 6. Concrete admixtures 7. Material 11111111111 8. Insulation forms 9. Plastics 10. Deck-roof • 11.Wall I le 12. Sheds 4 13. Other G. SKYLIGHTS _ 1. Skylight 2. Other Category/SubcategoryManufacturer (Product Description Limitation of Use State# Local# H.NEW EXTERIOR ENVELOPE PRODUCTS 1. 2. In addition to completing the above list of manufacturers, product description and State approval number for the products used on this project, the Contractor shall maintain on the job site and available to the Inspector, a legible copy of each manufacturer's printed specifications and installation instructions along with this Product Approval Sheet. I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the ones listed in this document must be approved by the Building Official. Boz I rr4 (Contractor Name) (Print Name) (S gn y► r ) LL _� Company Name: T Ai, j /el? Ji[2cc,P r,L Mailing Address: 5-4(6;5- V ung- 8100 City: 3/ ' 50;1v: State: re. Zip Code: 3Z Z(2)-5— Telephone c2 1Telephone Number: 604 ) 763 /0/0 Fax Number: ( , ( ) 7 3 /G/y Cell Phone Number: (10y ) g37 -a i( y E-mail Address: ,Te / e �jn�2�Kk2Ge/ , CG^l D/4-(14- eZ CG OFFICE COPY FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Johnson Renovation Builder Name: Street: 353 Second St Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach,FL, Permit Number: Owner: Jurisdiction: 261100 Design Location: FL,MAYPORT_NS County:: Duval(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1440.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.0 1440.00 ft2 b.N/A R= ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 2 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (1296.0 sqft.) Insulation Area a.Roof Deck(Unvented) R=21.0 1296.00 ft2 6. Conditioned floor area above grade(ft2) 1296 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(277.8 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 168.48 a. U-Factor: Dbl,U=0.40 277.80 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 24.2 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 22.0 HSPF:9.00 SHGC: Area Weighted Average Overhang Depth: 3.587 ft. Area Weighted Average SHGC: 0.250 14.Hot water systems a.Electric Tankless Cap: 1 gallons 8. Floor Types (1296.0 sqft.) Insulation Area EF:0.950 a.Crawlspace R=13.0 1296.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Total Proposed Modified Loads: 48.73 Glass/Floor Area: 0.214 PASS Total Baseline Loads: 49.91 I hereby certify that the plans and specifications covered by Review of the plans andIHE S7' 1, this calculation are in compliance with the Florida Energy specifications covered by this ... FO Code. calculation indicates compliancea0 r" ` � { Q . Ryan B.Ellis with the Florida Energy Code. .1+L.,rni, 4,, ', 4 PREPARED BY: _-__ - Before construction is completed �, + . t .4 .....ate C/ DATE: _-____ 9/2s/17 _- this building will be inspected for :t;',,,..4),1,4- b compliance with Section 553.908 '\ *`,. ash °: '• * 5' ` I hereby certify that this building,as design-. is in compliance Florida Statutes. ,, 'l4;.. '.1 'TO'..' with the Florida Energy Code •.GQD .9._"n OWNER/AGENT-__ _ ___ ______ BUILDING OFFICIAL: fri DATE: _- -/G . DATE: - "1//'00:71/7 - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1, 2017 this project requires an envelope leakage test report with envelope leakage no greater than 7.0 ACH50(R402.4.1.2). 9/29/2017 11:07 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 1 of 4 FORM R4G5-2014 PROJECT Title: Johnson Renovation Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1296 Lot# Owner: Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 353 Second St Permit Office: Atlantic Beach Cross Ventilation: County: Duval Jurisdiction: 261100 Whole House Fan: City,State.Zip: Atlantic Beach, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE V Design Location TMY SiteIECC Design Temp Int Design Temp Heating Design Daily Temp Zone 9T5% 2.5% Winter Summer Degree Days Moisture Range FL,MAYPORT NS FL MAYPORT NS 2 39 90 70 75 1037 61 Medium BLOCKS Number Name Area Volume 1 BloCk1 1296 12960 SPACES Number Name Area Volume Kitchen Occupants Bedrooms infilID Finished Cooled Heated 1 Main 1296 12960 Yes 3 2 1 Yes Yes Yes FLOORS V # Floor Type Space Exposed Peri Wall Ins.R-Value Area Floor Joist R-Value Tile Wood Carpet 1 Crawlspace= Main 144 ft 0 1296 ft2 13 0 0 1 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Composition shingles 1449 ft2 324 ft2 Medium 0.85 No 0.9 No 21 26.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Unvented 0 1296 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Unvented) Main 0 Blown 1296 ft2 0.11 Wood 9/29/2017 11:07 AM EnergyGauge®USA-v5.1-Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2014 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below # __Ornt _ To Wall Typo Space R-VaIuf, _._Et In Et In Area__-_R Value Fraction Ahsor.-Gradp°/u__ 1 S Exterior Concrete Block-Int Insul Main 4 16 10 160.0 ft' 0 0.170000 0 _ 2 S Exterior Concrete Block-Int Insul Main 4 20 10 200.0 ft' 0 0.170000 0 3 E Exterior Concrete Block-Int Insul Main 4 36 10 360.0 ft' 0 0.170000 0 _ 4 N Exterior Concrete Block-Int Insul Main 4 30.3 10 303.0 ft' 0 0.170000 0 _ 5 N Exterior Concrete Block-Int Insul Main 4 5.7 10 57.0 ft2 0 0.170000 0 6 W Exterior Concrete Block-Int Insul Main 4 36 10 360.0 ft' 0 0.170000 0 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 S 1 Vinyl Low-E Double Yes 0.4 0.25 30.0 ft' 2 ft 0 in 5 ft 0 in Drapes/blinds None 2 S 2 Vinyl Low-E Double Yes 0.4 0.25 30.0 ft' 10 ft 0 in 3.5 ft 0 in Drapes/blinds None 3 S 2 Vinyl Low-E Double Yes 0.4 0.25 20.1 ft' 10 ft 0 in 3.5 ft 0 in Drapes/blinds None 4 E 3 Vinyl Low-E Double Yes 0.4 0.25 45.0 ft' 2 ft 0 in 8 ft 0 in Drapes/blinds None 5 N 4 Vinyl Low-E Double Yes 0.4 0.25 30.0 ft2 2 ft 0 in 5 ft 0 in Drapes/blinds None 6 N 5 Vinyl Low-E Double Yes 0.4 0.25 20.1 ft' 4 ft 0 in 5 ft 0 in Drapes/blinds None 7 N 4 Vinyl Low-E Double Yes 0.4 0.25 22.5 ft' 2 ft 0 in 1 ft 0 in Drapes/blinds None 8 W 6 Vinyl Low-E Double Yes 0.4 0.25 60.0 ft' 2 ft 0 in 10 ft 0 in Drapes/blinds None 9 W 6 Vinyl Low-E Double Yes 0.4 0.25 20.1 ft' 2 ft 0 in 14 ft 0 in Drapes/blinds None INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000445 1512 83.01 156.11 .3425 7 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:9 22 kBtu/hr 1 sys#1 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER:16 24.2 kBtu/hr 726 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Tankless Main 0.95 1 gal 50 gal 120 deg None 9/29/2017 11:07 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2014 SOLAR HOT WATER SYSTEM V FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS ---Supply-- —Return--- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 168.48 f Attic 64.8 ft2 Default Leakage Attic (Default)c(Default)c 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan Feb Mar Apr MayX Jun X Jul X Aug SepOct Nov HeatinX`Jan ;Xi Feb X Mar ' ' AprApf MaL Jun t ;Jul 4 Aug Se Oct X Nov tX1?)eecc Ventin Jan Feb 'X' Mar X r [ Ma [ Jun [ Jul [ Au SepX Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 9/29/2017 11:07 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. 353 Second St, Atlantic Beach, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.0 1440.00 ft2 b.N/A R= ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 2 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types Insulation Area a.Roof Deck(Unvented) R=21.0 1296.00 ft2 6. Conditioned floor area(ft2) 1296 b.N/A R= ft2 c.N/A R= ft2 7. Windows"` Description Area 11.Ducts R ft2 a. U-Factor: Dbl,U=0.40 277.80 ft2 a.Sup:Attic,Ret:Attic,AH:Attic 6 168.48 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 24.2 SEER:16.00 SHGC: d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 22.0 HSPF:9.00 Area Weighted Average Overhang Depth: 3.587 ft. Area Weighted Average SHGC: 0.250 8. Floor Types Insulation Area 14.Hot water systems a.Crawlspace R=13.0 1296.00 ft2 a.Electric Cap: 1 gallons EF:0.95 b.N/A R= ft2 c.N/A R= ft2 b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building .-•''''''"4*---... ^�kIE st Construction through the above energy saving features which will be installed (or exceeded) r"'��4:), , ^ R�'c ''1/4, .y O in this home before final inspection. Otherwise, a new EPL Display Card will be completed ,' �_- ��,`� based on installed Code cam.liant f-atur- 'ti Trow,? '- � fi.,'',,mo0`; //� //--/0--( c " ^ / �, �R, Builder Signature: Date: / - :v`; ,�' Address of New Horn- City/FL Zip: • r 'V *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 9/29/2017 11:07 AM EnergyGauge®USA-v5.1- Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 • Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: 353 Second St Permit Number: Atlantic Beach ,FL, MANDATORY REQUIREMENTS See individual code sections for full details. X 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL)display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law[Section 553.9085, Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. X R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. X R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4 1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. R402,4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7). Florida Statutes or individulas licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures: 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors, if installed at the time of the test,shall be open; 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off:and 6.Supply and return registers,if installed at the time of the test,shall be fully open. X R402.4.2 Fireplaces.New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. X R402.4.3 Fenestration air IeakageWindows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. X R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 L/s)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. X R403.1.1 Thermostat provision(Mandatory).At least one thermostat shall be provided for each separate heating and cooling system. X R403.1.3 Heat pump supplementary heat(Mandatory)Heat pumps having supplementary electric-resistance heat shall have controls that, except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. X R403.2.2 Sealing(Mandator All ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers, shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either individuals as defined in Section 553.993(5)or(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i), Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test.If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm(85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 9/29/2017 11:07 AM EnergyGauge®USA-v5.1 - Section R405.4.1 Compliant Software Page 1 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) X R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. X R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C)or below 55°F(13`C)shall be insulated to a minimum of R-3., R403.3.1 Protection of piping insulation. 0 R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. X R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3'/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. X R403.4.4 Water heater efficiencies(Mandatory). X R403.4.4.1 Storage water heater temperature controls ▪ R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). ▪ R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off A separate valve shall be provided to permit the energy supplied to the main burner(s)of combustion types of service water heating systems to be turned off. X R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. ▪ R403.4.4.2.1 Solar water heating systems.Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors,and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. p R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential or Florida Building Code,Mechanical.as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. X R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. X R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 9/29/2017 11:07 AM EnergyGauge®USA-v5.1 - -Section R405.4.1 Compliant Software Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) X R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfrn provided by the expanded performance data,the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1 Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. X R403.6.1.2 Heating equipment capacity ▪ R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. ▪ R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. ▪ R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. X R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. ▪ R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps. Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or solar ' energy source computed over an operating season. X RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights X R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. X R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space, R-10 is allowed. 9/29/2017 11:07 AM EnergyGauge®USA-v5.1 - -Section R405.4.1 Compliant Software Page 3 of 3 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Johnson Renovation Builder Name: Street: 353 Second St Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach,FL, Permit Number: Owner: Jurisdiction: 261100 Design Location: FL,MAYPORT_NS COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. X Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. X Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in X substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and X Rim joists Rim joists are insulated and include an air barrier. X Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. X The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. X Exposed earth in unvented crawl spaces shall be covered with a Class I Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or X unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity X spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. X Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be X air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to X available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air X barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or X air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be X sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have X gasketed doors 9/29/2017 11:07 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 1 of 1 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: Johnson Renovation Builder Name: Street: 353 Second St Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach,FL, Permit Number: Design Location: FL,MAYPORT_NS Jurisdiction: 261100 Cond. Floor Area:: 1296 sq.ft. Cond.Volume: 12960 cu ft. Envelope Leakage Test Results Leakage Characteristics Regression Data: CFM(50): C: n: R: — ELA: Single or Multi Point Test Data HOUSE PRESSURE FLOW: EqLA: 1 Pa cfm ACH: 2 Pa cfm SLA: 3 Pa cfm ACH(50) * : 4 Pa cfm * For prescriptive projects, tested leakage must be 5 Pa cfm <=7 ACH(50). For performance projects, tested 6 Pa cfm leakage must be <= the ACH(50) shown on Form R405-2014 for this project. R402.4.1.2 Testing.The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either • individuals as defined in Section 553.993(5)or(7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed.beyond the intended weatherstripping or other infiltration control measures; 2. Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6. Supply and return registers,if installed at the time of the test,shall be fully open. W. Testing shall be conducted by either ",,IttE I performanceereby certify y thast the he above en complianceloleakage individuals as defined in Section k, y0 [Y• ....... 44 553.993(5) or (7), Florida Statutes or t ti,'�" 'tf:J with Florida Energy Code requirements in '�. • ��:� individuals licensed as set forth in � ti ,, _ �; p z accordance with Section R402.4.1.2. Section 489.105(3)(f), (g), or (i) or an W _ '' ; - approved third party. A written report04 ` ■ of the results of the test shall be *• , SIGNATURE: . signed by the third party conducting �"'�,. C , y the test and provided to the code s OD wE' ',./ PRINTED NAME: BUILDING OFFICIAL: DATE: — DATE: 9/29/2017 11:07 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 1 of 1 Date:Project 4 wrightsoft"' 1 Summary Date: 8/31117 Entire House By: M.Ellis Energy Design Systems, Inc. 11727 Brady Rd,Jacksonville,FL 32223 Phone:904-268-3670 Fax:904-268-3670 Email:eds.jax@gmail,corn Pro'ect Information For: Johnson Renovation 353 Second St,Atlantic Beach, FL Notes: Desi• n Information Weather: Mayport Ns, FL, US Winter Design Conditions Summer Design Conditions Outside db 38 °F Outside db 94 °F Inside db 68 °F Inside db 75 °F Design TD 30 °F Design TD 19 °F Daily range L Relative humidity 50 % Moisture difference 50 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 16612 Btuh Structure 18848 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower e) 0 Btuh Piping 0 Btuh Equipment load 16612 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 18848 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 2498 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 1296 1296 Equipment latent load 2498 Btuh Volume(ft3) 12960 12960 Air changes/hour 0.54 0.23 Equipment total load 21346 Btuh Equiv.AVF (cfm) 117 50 Req. total capacity at 0.80 SHR 2.0 ton Heating Equipment Summary Cooling Equipment Summary Make Trane Make Trane Trade TRANE Trade TRANE Model 4TWR6024H 1 Cond 4TWR6024H 1 AHRI ref 7562095 Coil TEM6A0B24H21++TDR AHRI ref 7562095 Efficiency 9 HSPF Efficiency 13.0 EER, 16 SEER Heating input Sensible cooling 16940 Btuh Heating output 22000 Btuh @ 47°F Latent cooling 7260 Btuh Temperature rise 25 °F Total cooling 24200 Btuh Actual air flow 807 cfm Actual air flow 807 cfm Air flow factor 0.049 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.88 Capacity balance point = 31 °F Backup: Input= 5 kW, Output= 16612 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. WPI 17SOt#' 2017-Sep-2911:13:03 g Right-Suite®Universal 2017 17.0.17 RSU17457 Page 1 ACCA . .\Johnson Renovation,353 Second St,Atl Bch.rup Calc=MJ8 Front Door faces: S Manual S Compliance Report Job: -+ Wrightsoft� Date: 8!31!17 Entire House By: M.Ellis Energy Design Systems, Inc. 11727 Brady Rd,Jacksonville, FL 32223 Phone: 904-268-3670 Fax:904-268-3670 Email.eds.jax@gmaiLcom Project Information For: Johnson Renovation 353 Second St,Atlantic Beach, FL Cooling Equipment Design Conditions Outdoor design DB: 94.4°F Sensible gain: 18848 Btuh Entering coil DB: 75.0°F Outdoor design WB: 77.4°F Latent gain: 2498 Btuh Entering coil WB: 62.5°F Indoor design DB: 75.0°F Total gain: 21346 Btuh Indoor RH: 50% Estimated airflow: 807 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Trane Model: 4TWR6024H1+TEM6A0B24H21++TDR Actual airflow: 807 cfm Sensible capacity: 19118 Btuh 101% of load Latent capacity: 5082 Btuh 203% of load Total capacity: 24200 Btuh 113% of load SHR: 79% Heating Equipment Design Conditions Outdoor design DB: 38.1°F Heat loss: 16612 Btuh Entering coil DB: 68.0°F Indoor design DB: 68.0°F Manufacturer's Performance Data atActual Design Conditions Equipment type: Split ASHP Manufacturer. Trane Model: 4TWR6024H1+TEM6A0B24H21++TDR Actual airflow: 807 cfm Output capacity: 22000 Btuh 132% of load Capacity balance: 31 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 807 cfm Output capacity: 4.9 kW 100% of load Temp. rise: 45 °F Meets are all requirements of ACCA Manual S. 2017-Sep-29 11:10:14 wrightsoftd RightSuite®Universal 2017 17.0.17 RSU17457 Page 1 ACCA ...\Johnson Renovation,353 Second St,Ati Bch.rup Calc=MJ8 Front Door faces: S N Sheet 1 Bath 2 111 261 cfm IN 42 cf Bath 1 Bed 1 Bed 2 34 m 4 133 cfm 4 " 8 ,. 9 f OP - cfm WIC4 „ • 6 „ -. 37 cfm 214 cfm 4 „ Entry 10 " „ 6 „ 12Ira 200 cfm 327 ofm 66 93 cfm a 93 cfm Kitchen Living ,lob #: Exclusively for the use of: Scale: 1 :60 Performed for: Page 1 Johnson Renovation Arctic Air of NE Florida Right-SuiteCk Universal 2017 353 Second St 17.0.17 RSU17457 Atlantic Beach, FL 2017-Sep-29 11:12:31 ...tion, 353 Second St.At'Bch.rup F Duct System SummaryJob: 4 wrightsoft yDate: Entire House By: Exclusively for the use of: Arctic Air of NE Florida Project Information For: Johnson Renovation 353 Second St,Atlantic Beach, FL Heating Cooling External static pressure 0.10 in H2O 0.10 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.10 in H2O 0.10 in H2O Supply/ return available pressure 0.065/ 0.035 in H2O 0.065/0.035 in H2O Lowest friction rate 0.078 in/100ft 0.078 in/100ft Actual air flow 800 cfm 800 cfm Total effective length (TEL) 129 ft Supply Branch Detail Table Design Htg Clg Design , Diam , H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk Bath 1 c 1009 33 34 0.082 4.0 Ox 0 VIFx 8.2 70.0 Bath 2 c 1240 41 42 0.080 4.0 Ox 0 VIFx 10.4 70.0 Bed 1 h 3868 133 130 0.078 6.0 Ox 0 VlFx 13.0 70.0 Bed 2-A h 4800 164 163 0.081 7.0 Ox 0 VIFx 9.5 70.0 Entry c 1101 36 37 0.086 4.0 Ox 0 VIFx 5.1 70.0 Kitchen-A c 5838 200 200 0.078 7.0 Ox 0 VIFx 12.5 70.0 Living h 2711 93 93 0.085 6.0 Ox 0 VIFx 6.0 70.0 living-A h 2711 93 93 0.081 6.0 Ox 0 VIFx 10.0 70.0 wnc c 265 7 9 0.085 4.0 Ox 0 VIFx 5.8 70.0 Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk rb3 Ox 0 213 214 37.0 0.096 392 10.0 Ox 0 VIFx rb2 Ox 0 261 260 45.6 0.078 748 8.0 Ox 0 VIFx rb1 Ox 0 326 327 36.7 0.097 416 12.0 Ox 0 VIFx BokJitalic values have been manually overridden 2017-Sep-29 11:11:57 1 -Pk wrightsoft° Right-Suite®Universal 2017 17.0.17 RSU17457 Page 1 ...1Johnson Renovation,353 Second St,AU Bch.rup Calc=MJ8 Front Door faces: S IMICC Most Widely Accepted and Trusted EVALUATION SERVICE (.. innovation •PESG.4RCH Ln�<. ICC-ES Evaluation Report ESR-3210 ICC-ES I (800)423-6587 I (562) 699-0543 I www.icc-es.org Reissued 03/2017 This report is subject to renewal 03/2018. DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION SECTION: 07 21 00—THERMAL INSULATION OFFICE COPY REPORT HOLDER: DEMILEC (USA) INC. 3315 EAST DIVISION STREET ARLINGTON, TEXAS 76011 EVALUATION SUBJECT: HEATLOK SOY® 200 PLUS SPRAY-APPLIED POLYURETHANE FOAM INSULATION ICC ICC ICC '. . , PMc G LISTED Look for the trusted marks of Conformity! "2014 Recipient of Prestigious Western States Seismic Policy Council SIM (WSSPC)Award in Excellence" A Subsidiary of OOFcouec r ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not °"`8-PfS 1° specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a ANSI g recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as ACCREDITED ISOnFC to any finding or other matter in this report, or as to any product covered by the report. P,06rI1TO6"6 80,4 coe ., Copyright© 2017 ICC Evaluation Service, LLC. All rights reserved. c L'J Vii:L!NT I br; S RV!CE Most Widely Accepted and Trusted ICC-ES Evaluation Report ESR-3210 Reissued March 2017 Revised June 2017 This report is subject to renewal March 2018. www.icc-es.orq I (800) 423-6587 I (562) 699-0543 A Subsidiary of the International Code Council° DIVISION: 07 00 00—THERMAL AND MOISTURE Attributes verified: PROTECTION See Section 3.1 Section: 07 21 00—Thermal Insulation 2.0 USES REPORT HOLDER: HEATLOK SOY® 200 PLUS spray-applied polyurethane foam plastic insulation is used as a nonstructural thermal DEMILEC (USA) INC. insulating material in Types I, II, Ill, IV and V construction 3315 EAST DIVISION STREET under the IBC and in dwellings under the IRC. The ARLINGTON,TEXAS 76011 insulation is intended for use in wall cavities, floor/ceiling (817)640-4900 assemblies, or attics and crawl spaces when installed in www.demilecusa.com accordance with Section 4.4. Under the IRC, the insulation info(&demilecusa.com may be used as air-impermeable insulation when installed in accordance with Section 3.4. When installed in EVALUATION SUBJECT: accordance with Section 4.5, the insulation may be used as an alternative to the water-resistive barriers required in HEATLOK SOY®200 PLUS SPRAY-APPLIED IBC Section 1404.2 and IRC Section R703.2. The POLYURETHANE FOAM INSULATION insulation may be used in nonload-bearing, fire-resistance- rated walls when construction is in accordance with 1.0 EVALUATION SCOPE Section 4.6. The insulation also may be used in exterior 1.1 Compliance with the following codes: walls of Type I, II, Ill or IV construction when used as described in Section 4.7. • 2015, 2012 and 2009 International Building Code®(IBC) 3.0 DESCRIPTION • 2015, 2012 and 2009 International Residential Code® 3.1 General: (IRC) • 2015, 2012 and 2009 International Energy Conservation HEATLOK SOY® 200 PLUS spray-applied foam insulation Code®(IEC C) is rigid, medium-density, polyurethane foam plastic that is installed as a component of floor/ceiling and wall • 2013 Abu Dhabi International Building Code(ADIBC)t assemblies. The insulation is a two-component, spray- tThe ADIBC is based on the 2009 IBC.2009 IBC code sections referenced applied foam plastic with a nominal in-place density of in this report are the same sections in the ADIBC. 2.0 pcf. The insulation is produced in the field by ■ Other Codes(see Section 8.0) combining a polymeric isocyanate (A-PDMI component) with a polymeric resin (HEATLOK SOY® 200 PLUS B-side Properties evaluated: component). The insulation liquid components are supplied • Surface burning characteristics in 55-gallon (208 L) drums and/or 250-gallon (946 L) totes and have a shelf life of one year when stored in factory- • Physical properties sealed containers at temperatures between 59°F (15°C) and 77°F(25°C). • Thermal resistance • Attic and crawl space installation The attribute of the insulation has been verified as conforming to the provision of ICC 700-2008 Section • Air permeability 703.2.1.1.1(c) as an air impermeable insulation. Note that • Water vapor transmission decisions on compliance for those areas rest with the user of this report. The user is advised of the project-specific • Water-resistive barrier provisions that may be contingent upon meeting specific • Fire-resistance-rated construction conditions, and the verification of those conditions is outside the scope of this report. These codes or standards • Exterior walls in Types I through IV construction often provide supplemental information as guidance. 1.2 Evaluation to the following green standard: 3.2 Surface-burning Characteristics: 2008 ICC 700 National Green Building StandardTM (ICC The insulation, at a maximum thickness of 4 inches 700-2008) (102 mm) and a nominal density of 2.0 pcf, has a flame- ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed • cro as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as to any finding or other matter in this report,or as to any product covered by the report. Copyright©2017 ICC Evaluation Service,LLC.All rights reserved. Page 1 of 6 ESR-3210 I Most Widely Accepted and Trusted Page 2 of 6 spread index of 25 or less and a smoke-developed index of installed at a minimum thickness of 11/2 inches (38 mm). 450 or less when tested in accordance with ASTM E84 (UL The insulation must be applied in passes not exceeding 723). There is no thickness limitation when the insulation is 2 inches (51 mm) per pass and must be allowed to fully installed behind a code-prescribed 15-minute thermal expand and cure for a minimum of 20 minutes prior to the barrier complying with, and installed in accordance with, application of the next additional pass. the applicable code. 4.3 Thermal Barrier: 3.3 Thermal Resistance,R-values: 4.3.1 Application with a Prescriptive Thermal Barrier: The insulation has thermal resistance (R-value) at a mean HEATLOK SOY® 200 PLUS insulation must be separated temperature of 75°F (24°C)as shown in Table 1. from the interior of the building by an approved thermal 3.4 Vapor Retarder: barrier of/2-inch-thick (12.7 mm) gypsum wallboard or an equivalent 15-minute thermal barrier complying with, and The insulation has a vapor permeance of less than 1 perm installed in accordance with, IBC Section 2603.4 or IRC [5.7x10-" kg/(Pa-s-m2)], in accordance with ASTM E96, Section R316.4, as applicable, except where insulation is when applied at a minimum thickness of 1.2 inches in an attic or crawl space as described in Section 4.4. (30.5 mm), and qualifies as Class II vapor retarder under There is no thickness limitation when the insulation is the IRC. installed behind a code-prescribed 15-minute thermal 3.5 Air Permeability: barrier. The insulation, at a minimum thickness of 11/2 inches 4.3.2 Application without a Prescriptive Thermal (38 mm), is considered air-impermeable insulation in Barrier: The prescriptive 15-minute thermal barrier or accordance with 2015 IBC Section 1203.3 or 2012 IRC ignition barrier may be omitted when installation is in Section R806.5 (2009 IRC Section R806.4), based on accordance with this section (Section 4.3.2) and Table 2. testing in accordance with ASTM E283 and ASTM E2178. The insulation and intumescent coating may be spray- applied to the interior facing of walls, the underside of the 3.6 Fire-protective Coating: roof sheathing or roof rafter, and in crawl spaces, and may 3.6.1 BlazeLokTM TBX: BlazeLokTM TBX (see ESR- be left exposed as an interior finish without a prescribed 3997), manufactured by TPR2 Corporation, is a one- 15-minute thermal barrier or ignition barrier. The thickness component, water-based intumescent coating. The coating of the foam plastic and coating must be as described in is supplied in 5-gallon (19 L) pails and 55-gallon (208 L) Table 2. The foam plastic must be covered on all surfaces drums and has a shelf life of 12 months when stored in with one of the coatings as set forth in Table 2.The coating factory-sealed containers at temperatures between 45°F must be applied over the insulation in accordance with the (7°C) and 90°F (32°C). The coating is applied in one coat coating manufacturer's instructions and this report. The in accordance with the coating manufacturer's published BlazeLokTM TBX must be applied over the insulation in installation instructions. accordance with the coating manufacturer's instructions, ESR-3997 and this report. The DC 315 Coating must be 3.6.2 DC 315 Coating: DC 315 Coating (see ESR-3702), applied over the insulation in accordance with the coating manufactured by International Fireproof Technology, Inc. / manufacturer's instructions, ESR-3702 and this report. Paint to Protect Inc., is a water-based, intumescent coating Surfaces to be coated must be dry, clean, and free of dirt, supplied in 5-gallon (19 L) pails and 55-gallon (208 L) loose debris and other substances that could interfere with drums. The coating material has a shelf life of 12 months adhesion of the coating. when stored in factory-sealed containers at temperatures between 50°F (10°C)and 80°F(27°C). 4.4 Ignition Barrier—Attics and Crawl Spaces: 4.0 INSTALLATION 4.4.1 Application with a Prescriptive Ignition Barrier: When the spray-applied insulation is installed within attics 4.1 General: or crawl spaces where entry is made only for service of HEATLOK SOY® 200 PLUS spray-applied polyurethane utilities, an ignition barrier must be installed in accordance foam insulation must be installed in accordance with with IBC Section 2603.4.1.6 or IRC Section R316.5.3 the manufacturer's published installation instructions, or R316.5.4, as applicable. The ignition barrier must the applicable code and this report. A copy of the be consistent with the requirements for the type of manufacturer's published installation instructions must be construction required by the applicable code, and must be available at all times on the jobsite during installation. installed in a manner so the foam plastic insulation is not exposed. The insulation as described in this section may 4.2 Application: be installed in unvented attics in accordance with 2015 IBC The insulation is spray-applied on the jobsite using a Section 1203.3 or 2015 and 2012 IRC Section R806.5 volumetric positive displacement pump as identified in (2009 IRC Section R806.4). the Demilec application manual. The insulation must be 4.4.2 Application without a Prescriptive Ignition applied when the ambient temperature is greater than 23°F Barrier: (-5°C). The insulation must not be used in areas that have a maximum in-service temperature greater than 180°F General: HEATLOK SOY® 200 PLUS spray-applied (82°C). The foam plastic must not be used in electrical polyurethane foam insulation may be installed in attics and outlet or junction boxes or in contact with water, rain or crawl spaces as described in this section without the soil.The foam plastic must not be sprayed onto a substrate ignition barriers required by IBC Section 2603.4.1.6 and that is wet, or covered with frost or ice, loose scales, rust, IRC Sections R316.5.3 and R316.5.4, subject to the oil, or grease. The insulation must be protected from the following conditions: weather during and after application, except as specified in a. Entry to the attic or crawl space is only to service Section 4.5. Where insulation is used as an air utilities, and no storage is permitted. impermeable insulation, such as in unvented attic assemblies under 2015 and 2012 IRC Section R806.5 b. There are no interconnected attic or crawl space (2009 IRC IRC Section R806.4), the insulation must be areas. ESR-3210 I Most Widely Accepted and Trusted Page 3 of 6 c. Air in the attic or crawl space is not circulated to other insulation must comply with Section 2603.5 of the IBC and parts of the building. this section (Section 4.7), and Table 3. The potential heat of Demilec HEATLOK SOY® 200 PLUS insulation is d. Under-floor(crawl space)ventilation is provided when 1930 Btu/ft2 (21.8 Mj/m2)per inch of thickness when tested required by 2015 IBC Section 1203.4 (2015 and 2009 in accordance with NFPA 259. IBC Section 1203.3) or IRC Section R408.1, as applicable. 4.7.2 Specific Wall Assemblies: Wall assemblies e. Attic ventilation is provided when required by IBC complying with Section 4.6 must be as described in Table Section 1203.2 or IRC Section R806, except when 3' air-impermeable insulation is permitted in unvented 5.0 CONDITIONS OF USE attics in accordance with 2015 IBC Section 1203.3 or 2015 or 2012 IRC Section R806.5 (2009 IRC Section The HEATLOK SOY® 200 PLUS spray foam insulation R806.4). described in this report complies with, or is a suitable alternative to what is specified in, those codes listed in f. Combustion air is provided in accordance with IMC Section 1.0 of this report, subject to the following Section 701. conditions: 4.4.2.1 Attics and Crawl Spaces: In attics and crawl 5.1 The products must be installed in accordance with the spaces, the insulation may be spray-applied to the manufacturer's published installations instructions, underside of the roof sheathing and/or rafters, to the this evaluation report and the applicable code. If there underside of wood floors, and to vertical surfaces as are any conflicts between the manufacturer's described in this section. The thickness of the foam plastic published installation instructions and this report, this applied to the underside of the top of the space must not report governs. exceed 111/2 inches (292 mm), and the thickness when applied to vertical surfaces must not exceed 71/2 inches 5.2 The insulation must be separated from the interior of (191 mm). the building by an approved 15-minute thermal 4.4.2.2 Use on Attic Floors: The spray applied foam barrier, except when installation is as described in Sections 4.3.2 and 4.4.2. A thermal barrier must be insulation may be installed at a maximum thickness of installed between the insulation and the interior space 71/2 inches (191 mm) between and over the joists in attic above (crawl space)or below(attic). floors. 4.5 Water-resistive Barrier: 5.3 The insulation must not exceed the thicknesses noted in Sections 3.2,4.3,4.4,4.6, and 4.7. HEATLOK SOY®200 PLUS insulation may be used as the water-resistive barrier prescribed in IBC Section 1404.2 5.4 The insulation must be protected from exposure to and IRC Section R703.2, when installed on exterior walls weather during and after application. as described in this section. The insulation must be spray- 5.5 The insulation must be applied by contractors applied to the exterior side of sheathing, masonry or other authorized by Demilec(USA)Inc. suitable exterior wall substrates to form a continuous layer of 11/2 inches (38 mm)minimum thickness. All construction 5.6 Use of the insulation in areas where the probability of joints and penetrations must be sealed with HEATLOK termite infestation is "very heavy" must be in SOY®200 PLUS insulation. accordance with 2015 and 2009 IBC Section 2603.8 (2012 IBC Section 2603.9) IRC Section R318.4, as 4.6 One-hour Nonload-bearing Fire-resistance-rated applicable. Wall Assemblies: 5.7 When use is on exterior walls of buildings of Types I, HEATLOK SOY® 200 PLUS insulation may be used as a II, Ill, and IV, construction must be as described in component of a one-hour fire-resistance-rated, nonload- Section 4.7. bearing wall assembly as described in this section (Section 4.6). 5.8 Jobsite certification and labeling of the insulation must 4.6.1 Interior and Exterior Face: Two layers of 5/8-inch- comply with 2015 IRC Sections N1101.10.1 and thick (15.9 mm), Type X gypsum board complying with N1101.10.1.1 (2012 IRC Sections N1101.12.1 and ASTM C36 or ASTM C1396 is installed on both the interior N1101.12.1.1 or 2009 IRC Sections N1101.4 and and exterior sides of 35/8-inch (92 mm), No. 20 gage, N1101.4.1 and 2015 and 2012 IECC Sections galvanized steel studs spaced 24 inches (610 mm) on C303.1.1, C303.1.1.1, R303.1.1 and R303.1.1.1 center. The base layer of the wallboard is secured with (2009 IECC Sections 303.1.1 and 303.1.1.1), as No. 6 by 11/4-inch-long (32 mm), self-drilling drywall screws applicable. 8 inches (203 mm) on center along the perimeter and 5.9 The insulation components A and B are produced in 12 inches on center(305 mm) in the field of the wallboard. Arlington, Texas and Boisbriand, Quebec, Canada, The face layer of the wallboard is secured with No. 6 by under a quality control program with inspections by 17/8-inch-long (48 mm), self-drilling drywall screws 8 inches ICC-ES. (203 mm) on center along the perimeter and in the field of the wallboard. Gypsum board joints must be taped and 6.0 EVIDENCE SUBMITTED joints and fasteners heads treated with joint compound in 6.1 Data in accordance with the ICC-ES Acceptance accordance with ASTM C840 or GA-216. Criteria for Spray-applied Foam Plastic Insulation 4.6.2 Stud Cavity: Nominally 35/8-inch-thick (92 mm) (AC377), dated April 2016, including reports of tests HEATLOK SOY® 200 PLUS foam insulation is spray- in accordance with AC377 Appendix X. applied in all stud cavities. 6.2 Reports of air leakage testing in accordance with 4.7 Exterior Walls of Type I, II, Ill and IV Construction: ASTM E283. 4.7.1 General: When used on exterior walls of Type I, II, 6.3 Reports of air permeance tests in accordance with III, and IV construction, the HEATLOK SOY® 200 PLUS ASTM E2178. ESR-3210 I Most Widely Accepted and Trusted Page 4 of 6 6.4 Reports of water vapor transmission test in • 2006 and 2003 International Residential Code®(IRC) accordance with ASTM E96. • 2006 and 2003 International Energy Conservation 6.5 Reports of room corner tests in accordance with Code®(IECC) NFPA 286. 8.2 Uses: 6.6 Reports of tests in accordance with ASTM E119. The products comply with the above-mentioned codes as 6.7 Reports of fire propagation characteristics tests in described in Sections 2.0 through 7.0 of this report, with accordance with NFPA 285. the revisions noted below: 6.8 Reports of potential heat of foam plastic tests in • Application with a Prescriptive Thermal Barrier: See accordance with NFPA 259. Section 4.3.1, except the approved thermal barrier must 6.9 Supplementary fire engineering analysis. be installed in accordance with Section R314.4 of the 2006 IRC or Section R314.1.12 of the 2003 IRC. 6.10 Data in accordance with the ICC ES Acceptance • Application with a Prescriptive Ignition Barrier: See Criteria for Foam Plastic Sheathing Panels Used as Section 4.4.1, except attics must be vented in Water-resistive Barriers (AC71), dated February 2003 accordance with Section 1203.2 of the 2006 and 2003 (editorially revised January 2016). IBC or Section R806 of the 2003 IRC; and crawl space 7.0 IDENTIFICATION ventilation must be in accordance with Section 1203.3 Components of the insulation are identified with the of the 2006 and 2003 IBC, or Section R408 of the IRC, manufacturer's name [Demilec (USA) Inc.], address and as applicable. Additionally, an ignition barrier must be telephone number; the product name (HEATLOK SOY® installed in accordance with Section R314.5.3 or 200 PLUS B-side or A-PDMI); use instructions; the R314.5.3 of the 2006 IRC or Section R314.2.3 of the density; the flame-spread and smoke-developed indices; 2003 IRC,as applicable. the date of manufacture; thermal resistance values; and • Application without a Prescriptive Ignition Barrier: the evaluation report number(ESR-3210). See Section 4.4.2, except attics must be vented in The TPR2 Corporation BlazelokTM TBX coating is accordance with Section 1203.2 of the 2006 and 2003 identified with the manufacturer's name, the product trade IBC, or Section R806 of the IRC; and crawl space name, use instructions and ICC-ES Evaluation Report ventilation must be in accordance with Section 1203.3 of number ESR 3997. the 2006 and 2003 IBC, or Section R408 of the IRC, as applicable. The International Fireproof Technology/Paint To Protect, • Protection Against Termites: See Section 5.6, except Inc. DC 315 Coating is identified with the manufacturer's use of the insulation in areas where the probability name, the product trade name, use instructions and ICC-ES Evaluation Report number ESR-3702. of termite infestation is "very heavy" must be in accordance with Section R320.5 of the 2006 IRC or 8.0 OTHER CODES Section R320.4 of the 2003 IRC. 8.1 Evaluation Scope: ■ Jobsite Certification and Labeling: See Section 5.8, In addition to the codes referenced in Section 1.0, the except jobsite certification and labeling must comply products described in this report have also been evaluated with Sections 102.1.1 and 102.1.11, as applicable, of the 2006 IECC. for compliance with the following codes: • 2006 and 2003 International Building Code®(IBC) TABLE 1-THERMAL RESISTANCE(R-VALUES) THICKNESS(inches) R-VALUE(°F.ft2.h/Btu) 1 7.4 1.2 8.8 1.5 11 2 14 3.5 24 4 27 5.5 36 7.5 50 9.25 62 9.5 63 10 66 11.25 75 11.5 76 For SI: 1 inch=25.4 mm; 1°F.ft2.h/Btu=0.176 110°K.m2/W. 'R-values are calculated based on tested K-values at 1-and 4-inch thicknesses. ESR-3210 I Most Widely Accepted and Trusted Page 5 of 6 TABLE 2—USE OF INSULATION WITHOUT A PRESCRIPTIVE THERMAL BARRIER INSULATION TYPE MAXIMUM MAXIMUM FIRE-PROTECTIVE COATING MINIMUM APPLICATION TESTS THICKNESS(in.) THICKNESS(in.) MINIMUM THICKNESS&TYPE RATE OF FIRE- SUBMITTED (Walls&Vertical (Ceilings,Underside of Roof (Applied to all Foam Surfaces) PROTECTIVE COATING Surfaces) Sheathing/Rafters&Floors) 71/2 111/2 Blazelok TBX 1.06 gal/100 ft2 NFPA 286 HEATLOK SOY 200 PLUS 17 wet mils/11 dry mils 71/2 111/2 18 wet mils 312 dry mils 1.13 gal/100 ft2 NFPA 286 For SI:1 inch=25.4 mm; 1 mil=0.0254 mm;1 gallon=3.38 L;1 ft2=0.93 m2;NA=not applicable. TABLE 3—NFPA 285 COMPLYING WALL ASSEMBLIES WALL COMPONENTS MATERIALS Base Wall System– 1 –Concrete wall. Use either 1,2 or 3 2–Concrete masonry wall. 3–Minimum 35/8-inch-deep(92 mm), No.20 gage,C-shaped steel studs,spaced a maximum of 24 inches on center with lateral bracing every 4 feet(1219 mm)as required by code.Sheathing shall be a described in Exterior Sheathing below. Floorline Firestopping Minimum 4 pcf mineral wool in each stud cavity at each floorline,attached with Z-clips.Thickness must match stud cavity depth. Cavity Insulation–Use either 1, 1 –None. 2,3 or 4 2–Partial cavity fill depth of 3 inches(76 mm)or full cavity depth of Heatlok Soy 200 Plus. 3–Glass fiber batt insulation°. 4–Mineral fiber insulation°. alnsulation must comply with the applicable requirements of 2015 or 2012 IBC Section 720.2(2009 IBC Section 719.2). Exterior Sheathing–Only for Minimum 5/8-inch-thick(15.9 mm),glass mat gypsum sheathing complying with ASTM C1177.Sheathing shall be Base Wall System No.3– attached with No.6, 11/4-inch-long(32 mm)self-tapping screws located 8 inches(203 mm)on center along the perimeter and 12 inches 302 mm)on center in the field of wallboard.Joints must be taped and treated with joint compound in accordance with ASTM C840 or GA-216. Exterior Insulation Maximum thickness of 3.4 inches(86 mm)of Heatlok Soy 200 Plus. Exterior Wall Covering– 1 –Brick-standard nominally 4-inch-thick(102 mm)clay brick;brick veneer anchors–standard types installed a Use either 1,2,3,4, 5 or 6 maximum of 24 inches OC vertically on each studb. 2–Stucco-minimum 3/4-inch-thick(19.1 mm),exterior cement plaster and lath with a secondary water-resistive barrier may be installed between the exterior insulation and the lath. 3–Natural stone(limestone,granite,marble,sandstone), minimum 2-inch-thick(51 mm)`. 4–Cast artificial stone,minimum 11/2-inch-thick(38 mm),complying with AC51 and subject of a current ICC-ES evaluation report`. 5–Terracotta cladding,minimum of 11/4-inch-thick(32 mm)`. 6–Concrete masonry units(CMU),minimum of 1'/2-inch-thick(38 mm)`. b The maximum air gap between exterior insulation and cladding shall be 2 inches(51 mm). Any standard non-open-jointed installation technique such as ship-lap,etc.,may be used. For SI: 1 inch=25.4 mm, 1 foot=304.8 mm, 1 pcf=16.01 kg/m3. 1 Insulation must comply with the applicable requirements of 2015 or 2012 IBC Section 720.2(2009 IBC Section 719.2). ICC EVALUATION SERVICE Most Widely Accepted and Trusted ICC-ES Evaluation Report ESR-3210 FBC Supplement Issued June 2017 This report is subject to renewal March 2018. www.icc-es.orci I (800) 423-6587 I (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 21 00—Thermal Insulation REPORT HOLDER: DEMILEC (USA) INC. 3315 EAST DIVISION STREET ARLINGTON,TEXAS 76011 (817)640-4900 www.demilecusa.com EVALUATION SUBJECT: HEATLOK SOY®200 PLUS SPRAY-APPLIED POLYURETHANE FOAM INSULATION 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that Demilec Heatlok SOY®200 PLUS medium density spray foam product, recognized in ICC-ES master evaluation report ESR-3210, has also been evaluated for compliance with the codes noted below. Applicable code editions: • 2014 Florida Building Code—Residential • 2014 Florida Building Code—Building 2.0 CONCLUSIONS The Demilec Heatlok SOY® 200 PLUS spray foam product, described in Sections 2.0 through 7.0 of the master evaluation report ESR-2642, complies with the 2014 Florida Building Code—Residential and 2014 Florida Building Code—Building, provided the design and installation are in accordance with the International Building Code® (IBC) provisions noted in the master report. Use of the Demilec Heatlok SOY® 200 PLUS spray foam product for compliance with the High-Velocity Hurricane Zone provisions of the 2014 Florida Building Code—Residential and 2014 Florida Building Code—Building has not been evaluated and is outside the scope of this supplemental report. For products falling under Florida Rule 9N-3, verification that the report holder's quality-assurance program is audited by a quality-assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity (or the code official, when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the master report, reissued March 2017 and revised June 2017. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed in as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as ANSI to any finding or other matter in this report,or as to any product covered by the report. inmploutW w Copyright©2017 ICC Evaluation Service,LLC. All rights reserved. Page 6 of 6 � c EsICC Most Widely Accepted and Trusted EVALUATION SERVICE CEInnovation t=i P SEA^CH n ICC-ES Report ESR-1172 ICC-ES I (800)423-6587 I (562) 699-0543 I www.icc-es.org Reissued 02/2017 This report is subject to renewal 02/2018. DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION SECTION: 07 21 00—THERMAL INSULATION OFFICE COPY REPORT HOLDER: DEMILEC (USA) INC. 3315 EAST DIVISION STREET ARLINGTON, TEXAS 76011 EVALUATION SUBJECT: SEALECTION® 500 SPRAY-APPLIED POLYURETHANE FOAM INSULATION LF:its_ThICC LEs_ ICC ICC PMG LISTED Look for the trusted marks of Conformity! ice\ "2014 Recipient of Prestigious Western States Seismic Policy Council ocCn(WSSPC)AwardinExcellence" A Subsidiary of cnncr ICC ES Evaluation Reports are not to be construed as representing aesthetics or anyrmcrcanea� other attributes not eccCBP/5 specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a ANSI recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as ' ISWfEC 17065 1to any finding or other matter in this report, or as to any product covered by the report. Puxtud CeAdIanen Body ,ka,„�y�p Copyright© 2017 ICC Evaluation Service, LLC. All rights reserved. SRV'„F 1!-,!'"eV,,;7 Most Widely Accepted and Trusted ICC-ES Evaluation Report ESR-1172 Reissued February 2017 This report is subject to renewal February 2018. www.icc-es.org I (800) 423-6587 I (562) 699-0543 A Subsidiary of the International Code Council° DIVISION: 07 00 00—THERMAL AND MOISTURE material in Type I, II, III, IV and Type V construction under PROTECTION the IBC and in dwellings under the IRC. The insulation is Section: 07 21 00—Thermal Insulation for use in wall cavities, floor/ceiling assemblies, or attics and crawl spaces when installed in accordance with REPORT HOLDER: Section 4.0. Under the IRC and the 2015 IBC, the insulation may be used as air-impermeable insulation DEMILEC (USA) INC. when installed in accordance with Section 3.4. The 3315 EAST DIVISION STREET insulation may be used in nonload-bearing, fire-resistance- ARLINGTON,TEXAS 76011 rated walls when construction is in accordance with (817)640-4900 Section 4.5. www.demilecusa.com info@demilecusa.com The attributes of the insulation have been verified as conforming to the provisions of ICC 700-2008 Section EVALUATION SUBJECT: 703.2.1.1.1(c) as an air impermeable insulation. Note that decisions on compliance for those areas rest with the user SEALECTION® 500 SPRAY-APPLIED POLYURETHANE of this report. The user is advised of the project-specific FOAM INSULATION provisions that may be contingent upon meeting specific conditions, and the verification of those conditions is 1.0 EVALUATION SCOPE outside the scope of this report. These codes or standards often provide supplemental information as guidance. 1.1 Compliance with the following codes: • 2015, 2012 and 2009 International Building Code®(IBC) 3.0 DESCRIPTION • 2015, 2012 and 2009 International Residential Code® 3.1 Materials: (IRC) SEALECTION® 500 spray-applied foam insulation is • 2015, 2012 and 2009 International Energy Conservation semirigid, low-density, polyurethane foam plastic that is Code®(IECC) installed as a component of floor/ceiling and wall • 2013 Abu Dhabi International Building Code(ADIBC)t assemblies.The insulation is a two-component spray foam plastic with a nominal in-place density of 0.5 pcf(8 kg/m3). tThe ADIBC is based on the 2009 IBC.2009 IBC code sections referenced The insulation is produced in the field by combining a in this report are the same sections in the ADIBC. polymeric isocyanate (A-PM DI component, A-Side ISO) • Other Codes(see Section 8.0) with a polymeric resin (SEALECTION® 500 B-Side Properties evaluated: component).The insulation liquid components are supplied • Surface burning characteristics in 55-gallon (208 L)drums and/or 250-gallon (946 L) totes and must be stored at temperatures between 50°F (10°C) • Physical properties and 100°F (38°C). The liquid components have a shelf life • Thermal resistance of one year when stored in factory-sealed containers at these temperatures. • Attic and crawl space installation 3.2 Surface-burning Characteristics: • Air permeability • Fire-resistance-rated construction The insulation, at a maximum thickness of 6 inches (152 mm)and a nominal density of 0.5 pcf(8 kg/m3), has a • Exterior walls in Type I through IV construction flame-spread index of 25 or less and a smoke-developed 1.2 Evaluation to the following green standard: index of 450 or less when tested in accordance with ASTM • 2008 ICC 700 National Green Building StandardTM (ICC E84. Greater thicknesses are recognized as described in 700-2008) Sections 4.3 and 4.4. SEALECTION® 500 thickness is not limited when separated from the interior of the building by Attributes verified: a prescriptive thermal barrier as complying with the IBC or ■ See Section 2.0 IRC and as described in Section 4.3.1. 2.0 USES 3.3 Thermal Resistance, R-values: SEALECTION® 500 spray-applied polyurethane foam The insulation has thermal resistance (R-value) at a mean insulation is used as a nonstructural thermal insulating temperature of 75°F (24°C)as shown in Table 1. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed QNS� as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC express or implied,as to any finding or other matter in this report,or as to any product covered by the report. E va „- Copyright©2017 ICC Evaluation Service,LLC. All rights reserved. Page 1 of 5 ESR-1172 I Most Widely Accepted and Trusted Page 2 of 5 3.4 Air Permeability: identified in the Demilec application guide. The insulation SEALECTION® 500 spray-applied polyurethane foam must be aplied when the ambient temperature is greater insulation, at a minimum thickness of 3.0 inches (76 mm), than 23°F (-5°C). The insulation must not be used in areas is considered air-impermeable insulation in accordance that have a maximum in-service temperature greater than with 2015 and 2012 IRC Section R806.5 (2009 IRC 180°F (82°C). The foam plastic must not be used in Section R806.4) and 2015 IBC Section 1203.3, based on electrical outlet or junction boxes or in contact with water, testing in accordance with ASTM E2178. rain or soil. The foam plastic must not be sprayed onto a substrate that is wet, or covered with frost or ice, loose 3.5 BlazelokT"' IB4 Intumescent Coating: scales, rust, oil, or grease. The insulation must be BlazelokTM IB4 intumescent coating, manufactured by protected from the weather during and after application. TPR2 Corporation, is a one-component, water-based liquid The insulation may be applied to the maximum thickness coating with specific gravity of 1.3. BlazelokTM IB4 is in a single pass. Where insulation is used as an air- supplied in 5-gallon (19 L) pails and/or 55-gallon (208 L) impermeable insulation, such as in unvented attic drums and has a shelf life of one year when stored in assemblies under 2015 and 2012 IRC Section R806.5 factory-sealed containers at temperatures between 45°F (2009 IRC Section R806.4) or 2015 IBC Section 1203.3, (7°C)and 90°F(32°C). the insulation must be installed at a minimum thickness of 3.6 BlazelokTM TB Intumescent Coating: 3.0 inches(76 mm). BlazelokTM TB intumescent coating, manufactured by TPR2 4.3 Thermal Barrier: Corporation, is a one-component, water-based liquid 4.3.1 Application with a Prescriptive Thermal Barrier: coating with specific gravity of 1.3. BlazelokTM TB is SEALECTION® 500 spray foam insulation must be supplied in 5-gallon (19 L) pails and/or 55-gallon (208 L) separated from the interior of the building by an approved drums and has a shelf life of one year when stored in thermal barrier of 1/2-inch-thick (12.7 mm) gypsum factory-sealed containers at temperatures between 45°F wallboard or an equivalent 15-minute thermal barrier (7°C)and 90°F(32°C). complying with, and installed in accordance with, IBC 3.7 BlazelokTM TBX Intumescent Coating: Section 2603.4 or IRC Section R316.4, as applicable, BlazelokTM TBX intumescent coating, manufactured byexcept where insulation is in an attic or crawl space as g° described in Section 4.4. SEALECTION® 500 thickness is TPR2 Corporation, is a one-component, water-based liquid not limited when separated from the interior of the building coating with specific gravity of 1.4. BlazelokTM TBX is by a prescriptive thermal barrier as complying with the IBC supplied in 5-gallon (19 L) pails and/or 55-gallon (208 L) or IRC. drums and has a shelf life of one year when stored in factory-sealed containers at temperatures between 45°F 4.3.2 Application without a Prescriptive Thermal (7°C)and 90°F(32°C). Barrier: The prescriptive 15-minute thermal barrier may be 3.8 Andek Firegard Intumescent Coating: omitted when installation is in accordance with this section and Table 2. SEALECTION® 500 spray foam insulation Andek Firegard intumescent coating, manufactured by and BlazelokTM TB, BlazelokTM TBX or DC 315 Andek Corporation, is a one-component, water-based intumescent coating may be spray-applied to the interior coating with specific gravity of 1.37. Andek Firegard is facing of walls, the underside of roof sheathing or roof supplied in 5-gallon (19 L) pails and has a shelf life of one rafters, and in crawl spaces, and may be left exposed as year when stored in factory-sealed containers at an interior finish without a prescribed 15-minute thermal temperatures between 45°F (7°C)and 90°F (32°C). barrier or ignition barrier. The foam plastic insulation 3.9 No-Burn®Plus XD Intumescent Coating: thickness must not exceed thicknesses stated in Table 2. ® All foam surfaces must be covered with intumescent No-Burn Plus XD intumescent coating, manufactured by coating, described in Section 3.6, at the minimum No-Burn, Inc., is a translucent aqueous liquid in 1- and thicknesses stated in Table 2. The intumescent coating 5-gallon (3.8 and 18.8 L) pails and 55-gallon (208 L) must be spray-applied over the insulation in accordance drums. The coating has a shelf life of three years when with the coating manufacturer's instructions and this report stored in a factory-sealed container at temperatures at a rate stated in Table 2 to obtain the recommended between 40°F (4.5°C)and 90°F(32°C). minimum dry film thickness noted in this section. 3.10 DC 315 Fireproof Paint: 4.4 Ignition Barrier-Attics and Crawl Spaces: DC 315, manufactured by International Fireproof Technology, Inc., is a one-component, water-based, liquid 4.4.1 Application with a Prescriptive Ignition Barrier: coating with a specific gravity of 1.3. DC 315 is supplied in When SEALECTION® 500 spray foam insulation is 5-gallon (19 L) pails and/or 55-gallon drums and has a installed within attics or crawl spaces where entry is made shelf life of one year when stored in unopened factory- only for service of utilities, an ignition barrier must be sealed containers between 50°F(10°C)to 80°F(27°C). installed in accordance with IBC Section 2603.4.1.6 or IRC 4.0 INSTALLATION Section R316.5.3 or R316.5.4, as applicable. The ignition barrier must be consistent with the requirements for the 4.1 General: type of construction required by the applicable code, and SEALECTION® 500 spray-applied foam insulation must be must be installed in a manner so the SEALECTION® plastic installed in accordance with the Center for Polyurethane insulation is not exposed. SEALECTION 500 spray Industries Guidance on Best Practices for the Installation of applied foam insulation as described in this section may be Spray Polyurethane Foam, the manufacturer's published installed in unvented attics in accordance with 2015 IBC technical data sheet and product application guide and this Section 1203.3 or 2015 and 2012 IRC Section R806.5 report. A copy of each document must be available at all (2009 IRC Section R806.4). times on the jobsite during installation. 4.4.2 Application without a Prescriptive Ignition 4.2 Application: Barrier: The SEALECTION® 500 insulation is spray-applied on the 4.4.2.1 General: SEALECTION® 500 spray-applied foam jobsite using a volumetric positive displacement pump as insulation may be installed in attics and crawl spaces, ESR-1172 I Most Widely Accepted and Trusted Page 3 of 5 without a prescriptive ignition barrier as described in IBC comply with Section 2603.5 of the IBC at a maximum Section 2603.4.1.6 and IRC Sections R316.5.3 and thickness of 35/8 inches (92 mm), when installed per the R316.5.4, in accordance with Section 4.4.2.2, 4.4.2.3, manufacturer's published product application guide and 4.4.2.4, or 4.4.2.5, when all of the following conditions this section. The potential heat of Demilec SEALECTION® apply: 500 spray polyurethane foam insulation is 496 Btu/ft2 a. Entry to the attic or crawl space is only to service (5.6 MJ/m2) per inch of thickness when tested in utilities, and no storage is permitted. accordance with NFPA 259. b. There are no interconnected attic or crawl space 4.6.1 Nonload-bearing NFPA 285-tested Wall areas. Assembly: c. Air in the attic or crawl space is not circulated to other 4.6.1.1 Interior Face: One layer of 5/8-inch-thick parts of the building. (16 mm), Type X gypsum wallboard complying with ASTM C36 or ASTM C1396 is installed with the long dimension d. Under-floor(crawl space) ventilation is provided when perpendicular to 35/8-inch-deep (92 mm), 20 gage steel required by 2015 IBC Section 1203.4 (2012 and 2009 studs spaced a maximum of 24 inches (609 mm) on IBC Section 1203.3) or IRC Section R408.1, as center. The wallboard is attached with 11/4-inch-long applicable. (31.8 mm), bugle head screws located 8 inches (203 mm) e. Attic ventilation is provided when required by IBC on center along the perimeter and 12 inches on center Section 1203.2 or IRC Section R806, except when air- (305 mm) in the field of the wallboard. Wallboard joints impermeable insulation is permitted in unvented attics in must be taped and treated with joint compound in accordance with 2015 IBC Section 1203.3 or 2015 and accordance with ASTM C840 or GA 216. Fastener heads 2012 IRC Section R806.5(2009 IRC Section R806.4). must also be treated with joint compound in accordance with ASTM C840 or GA-216. f. Combustion air is provided in accordance with IMC 4.6.1.2 Stud Cavity: SEALECTION®500 foam insulation, (International Mechanical Code) 701. in a maximum thickness of 35/8 inches (92 mm), is spray- 4.4.2.2 The insulation must be covered on all surfaces applied in all stud cavities. with a fire protective coating at the minimum thickness set 4.6.1.3 Exterior Face: One layer of 5/8-in chthick forth in Table 3. (16 mm)m GP DensGlass®sheathing attached to steel studs 4.4.2.3 The maximum installed thickness of the insulation using 1 /4-inch-long (31.8 mm), self-tapping screws spaced must not exceed the thicknesses set forth in Table 3. 8 inches (203 mm) on center along the perimeter and 4.4.2.4 The coating must be applied over the insulation in 12 inches on center(305 mm) in the field of the sheathing. accordance with the coating manufacturer's instructions Details of the exterior wall covering must be provided by and this report. the report holder, designer or specifier to the code official, with a fire engineering analysis demonstrating that the 4.4.2.5 Use on Attic Floors: SEALECTION® 500 spray- addition of the wall covering will not negatively affect applied foam insulation may be installed at a maximum conformance of the assembly with the requirements of IBC thickness between and over the joists in attic floors as set Section 2603.5. forth in Table 3. All exposed foam plastic surfaces must be 5.0 CONDITIONS OF USE covered with a minimum nominal thickness of the fire protective coatings as set forth in Table 3. The intumescent SEALECTION®500 spray foam insulation described in this coatings must be applied over the insulation in accordance report complies with, or is a suitable alternative to what is with the coating manufacturer's instructions and this report. specified in,those codes listed in Section 1.0 of this report, 4.5 One-hour Fire-resistance-rated Wall Assemblies subject to the following conditions: (Nonload-bearing): 5.1 The products must be installed in accordance with the Center for Polyurethane Industries"Guidance on Best SEALECTION® 500 foam insulation may be used as a component of a one-hour fire-resistance-rated, nonload Practices for the Installation of Spray Polyurethane bearing wall assembly as described in this section Foam", the manufacturer's published technical data (Section 4.5). sheet and product application guide, this evaluation report and the applicable code. If there are any 4.5.1 Interior and Exterior Face: One layer of 5/8-inch- conflicts between the manufacturer's published thick (16 mm), Type X gypsum wallboard complying with installation instructions and this report, this report ASTM C36 or ASTM C1396 is installed on the interior and governs. exterior side of nominally 2-by-6, No. 1, Southern yellow 5.2 The insulation must be separated from the interior of pine wood studs spaced 16 inches (406 mm) on center. the building by an approved 15-minute thermal The wallboard is attached with 15/8-inch-long (41 mm), coarse-thread drywall screws located 8 inches (203 mm) barrier, except when installation is as described in on center along the perimeter and 12 inches on center Sections 4.3.2 or 4.4.1 through 4.4.2.5. (305 mm) in the field of the wallboard. Wallboard joints 5.3 The insulation must not exceed the thicknesses noted must be taped and treated with joint compound in in Sections 3.2,4.2,4.3,4.4,4.5,and 4.6. accordance with ASTM C840 or GA-216. Fastener heads 5.4 The insulation must be protected from exposure to must also be treated with joint compound in accordance weather during and after application. with ASTM C840 or GA-216. 4.5.2 Stud Cavity: A nominally 51/2-inch (140 mm) 5.5 The insulation must be applied by contractors thickness of SEALECTION® 500 foam insulation is spray- authorized by Demilec(USA) Inc. applied in all stud cavities. 5.6 Use of the insulation in areas where the probability of 4.6 Exterior Walls of Type I, II, III and IV Construction: termite infestation is "very heavy" must be in accordance with IRC Section R318.4 or 2015 and When used on exterior walls of Type I, II, Ill and IV 2009 IBC Section 2603.8 (2012 IBC Section 2603.9), construction, the SEALECTION® 500 foam insulation must as applicable. ESR-1172 I Most Widely Accepted and Trusted Page 4 of 5 5.7 When use is on exterior walls of buildings of Type I, II, 8.0 OTHER CODES III, and IV, construction must be as described in 8.1 Evaluation Scope: Section 4.6. 5.8 See Section 4.5 for the fire-resistance-rated wall In addition to the codes referenced in Section 1.0, the assemblies. products recognized in this report have also been evaluated in accordance with the following codes: 5.9 Jobsite certification and labeling of the insulation must • 2006 International Building Code®(2006 IBC) comply with 2015 IRC Section N1101.10, 2012 IRC Section N1101.14, 2015 or 2012 IECC Sections ■ 2006 International Residential Code®(2006 IRC) C303.1, R303.1 and R401.3 [2009 IECC Section ■ 2006 International Energy Conservation Code® 303.1 and 401.3], as applicable. (2006 IECC) 5.10 The insulation is produced in Arlington, Texas, • 2003 International Building Code®(2003 IBC) under a quality-control program with inspections by ICC-ES. • 2003 International Residential Code®(2003 IRC) 6.0 EVIDENCE SUBMITTED • 2003 International Energy Conservation Code® 6.1 Data in accordance with the ICC-ES Acceptance (2003 IECC) Criteria for Spray-applied Foam Plastic Insulation 8.2 Uses: (AC377),dated May 2015, including reports of tests in The products comply with the above-mentioned codes as accordance with Appendix X. described in Sections 2.0 through 7.0 of this report except 6.2 Reports of fire propagation characteristics tests in as noted below: accordance with NFPA 285. ■ Application with a Prescriptive Thermal Barrier: See 6.3 Reports of air leakage testing in accordance with Section 4.3.1, except the approved thermal barrier must ASTM E283. be installed in accordance with Section R314.4 of the 6.4 Reports of air permeance tests in accordance with 2006 IRC or Section R314.1.12 of the 2003 IRC. ASTM E2178. • Application without a Prescriptive Thermal Barrier: 6.5 Reports of room corner tests in accordance with See Section 4.3.2. NFPA 286. ■ Application with a Prescriptive Ignition Barrier: See 6.6 Reports of tests in accordance with ASTM E119. Section 4.4.1, except attics must be vented in accordance with Section 1203.2 of the 2006 and 2003 6.7 Reports of potential heat tests in accordance with IBC or Section R806 of the 2003 IRC, and crawl space NFPA 259. ventilation must be in accordance with IBC Section 7.0 IDENTIFICATION 1203.3 of the 2006 and 2003 IBC or IRC Section R408, as applicable. Additionally, an ignition barrier must be Components of the spray foam insulation are identified installed in accordance with Sections R314.5.3 or with the manufacturer's name (Demilec (USA) Inc.), R314.5.3 of the 2006 IRC or Section R314.2.3 of the address and telephone number; the product name 2003 IRC, as applicable. (SEALECTION® A-PMDI or SEALECTION® 500 B • Application without a Prescriptive Ignition Barrier: Side); use instructions; the density; the flame-spread and See Section 4.4.2, except attics must be vented in smoke-developed indices; the date of manufacture; accordance with Section 1203.2 of the 2006 and 2003 thermal resistance values; and the evaluation report IBC or Section R806 of the IRC, and crawl space number(ESR 1172). ventilation must be in accordance with Section 1203.3 of Each pail of the BlazelokTM 1B4 and the BlazelokTM TB or the 2006 and 2003 IBC or IRC Section R408, as BlazelokTM TBX intumescent coating is labeled with the applicable. manufacturer's name (TPR2 Corporation), the product ■ Protection against Termites: See Section 5.6, except name, and use instructions. Each pail of Andek use of the insulation in areas where the probability of Corporations Firegard intumescent coating is labeled with termite infestation is "very heavy" must be in the manufacturers name(Andek Corporation)and address, accordance with Section R320.5 of the 2006 IRC or the product trade name, and use instructions. Section R320.4 of the 2003 IRC. No Burn® Plus XD intumescent coating is identified with • Jobsite Certification and Labeling: See Section 5.9, the manufacturer's name (No-Burn, Inc) and address, the except Jobsite certification and labeling must comply product trade name, and use instructions. with Sections 102.1.1 and 102.1.11, as applicable, of Each pail of DC315 is labeled with the manufacturer's the 2006 IECC. name (International Fireproof Technology Inc.), address, product trade name and use instructions. ESR-1172 I Most Widely Accepted and Trusted Page 5 of 5 TABLE 1—THERMAL RESISTANCE(R-VALUES) THICKNESS(inches) R-VALUE('F.ft2.hlBtu) 1 3.8 3.5 13 4 15 5.5 21 7 27 9.5 36 10 38 11.5 44 14 52 For SI: 1 inch=25.4 mm; 1 °F.ft2.h/Btu=0.176 110°K.m2/W. 'R-values are calculated based on tested K-values at 1-and 4-inch thicknesses. TABLE 2—USE OF INSULATION WITHOUT A PRESCRIPTIVE THERMAL BARRIER Maximum Insulation Maximum Insulation Fire Protective Coating Coating Thickness(in.) Thickness(in.) (Applied to all Foam Surfaces Vertical Surfaces Ceiling Surfaces Minimum Coating Dry Minimum Coating Wet Minimum Film Thickness(mils) Film Thickness(mils) Application Rate Blazelok TB 51/2 10 14 25 1 gal/82 ft2 Blazelok TBX 71/2 111/2 11 17 1 gal/85 ft2 DC315 7'12 111/2 12 18 1 gal/90 ft2 For SI: 1 inch=25.4 mm; 1 gal=3.785 L; 1 ft2=0.093 m2. TABLE 3—ATTIC OR CRAWL SPACE ASSEMBLIES WITHOUT A PRESCRIPTIVE IGNITION BARRIER Maximum Insulation Maximum Insulation Fire Protective Coating Coating Thickness(in.) Thickness(in.) (Apalied to all Foam Surfaces) Vertical Surfaces and Minimum Coating Dry Minimum Coating Minimum Attic Floors Ceiling Surfaces Film Thickness Wet Film Thickness Application Rate Blazelok IB4 91/4 111/4 5 9 1 gal/175 ft2 Andek Firegard 91/2 111/2 10 20 1 gal/100 ft2 No-Bum Plus XD 91/2 111/2 6 10 1 gal/160 ft2 DC 315 7'/211'/2 3 4 1 gal/??ft2 For SI: 1 inch=25.4 mm; 1 gal=3.785 L; 1 ft2=0.093 m2.