Loading...
353 2nd St ROW permit �p 11 it CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 19' INSPECTION PHONE LINE 247-5814 RIGHT OF WAY - SINGLE OR TWO FAMILY RIGHT OF WAY MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: ROW1 8-0004 Description: install 35-foot wood pole in right of way Estimated Value: 0 Issue Date: 2/22/2018 Expiration Date: 5/23/2018 PROPERTY ADDRESS: Address: 353 2ND ST RE Number: 1697860000 PROPERTYOWNER: Name: JOHNSONJOANN Address: 181 PROCTORS PURCHASE RD HARTLY, DE 19953 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: JACKSONVILLE ELECTRIC AUTHORITY Address: 21 CHURCH ST W 3RD FLR JACKSONVILLE, FL 32202 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. APPLICATION NUMBER City of Atlantic Beach Building Department (To be assigned by the Building Department.) r-hEIVE - ;01 800 Seminole Road V C)W .x Atlantic Beach, Florida 32233-5445 Phone (904)247-5826 - Fax(904)247-58F!EB 16 2018 E-mail: building-dept@coab.us ) - L Date routed: It City web-site: http-://www.coab.us Li APPLICATION REVIEW AND TRACKING FORM Property Address: "d �Sq Department review required Yes No Building Applicant: Planning &Zoning Tree Administrator "Oj CV_ubfic V___r Project: k o j�? (.Public Utili��s Public Safety Fire Services Review fee Dept Signature Other Agency Review or Permit Required Review or Receipt Date � of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engi-neers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: MApproved. E]Denied. [-]Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by�_f Date:-,z —J/ TREE ADMIN. Second Review: ElApproved as revised. OlDenied. E]Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: DApproved as revised. [—]Denied. E]Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 City of Atlantic Beach APPLICATION NUMBER -E C E I V E (To be assigned by the Building Department.) Building Department 800 Seminole Road 00tt Atlantic Beach, Florida 32233-5445 C)w Phone(904)247-5826 - Fax(904)2 4 7-49B 2018 E-mail: building-dept@coab.us te routed: L_�a City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: Department review required Yes No Building Applicant: t�, A Planning &Zoning Tree Administrator Project: L f) "'-j � - _Public Utiqg> Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPL,14:�ATION STATUS Reviewing Department First Review: [/Approved. []Denied. E]Not applicable (Circle one.) Comments: BUILDING 21- Z PLANNING & ZONING Reviewed by: Date: TREE ADMIN. Second Review: E]Approved as revised. F]Denied. Not applicable PeUWORKS gommepts: B �T.�r IT I E PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: []Approved as revised. E]Denied. ONot applicable Comments: Reviewed by: Date: Revised 05/19/2017 343 353 365 j S".qFVWR I ATFRAI 8" PVC WATER MAIN] 340 348 34G 352 3G4 ENGINEERING DESIGN ORACLE PERMIT MAXIMO DATE REL PROJECT#:32507 N.C.: 8004473 WO#: 30239631 CONST 02112/18 CIR. TREE TRIMMING SUB-STA NEPTUNE BEACH N.O.: 563 REQ'D:.YES CELL ENGINEER: Robert Simpson N.O.: NIA ZIP CODE: N/A CUSTOMER/ Svc PHONE LOCATION: 353 2ND STJ POLE INSTALLATION 563 Sssc N.O.:665-7793 CENTER. STA 1. P# 349 2ND ST./ INSTALL 35/4W POLE, RUN 210P TO STA 2. 3 ' D STA 2. P#3,50 2ND ST, EL-2018/00027.910 T'j uj Ln Ln Ln ON THIS IS FOR A NEW HOME BUILT 0-'j T 0 T 6 5-T 4T T STA 1 390 1* 350 370 360 345 3g4 390-1 3 2 35� 343 -265 3 0 367 3�3 4 50A 377 3V '*.Ull 4 't r'j 393 I/0-f -6C 4CU 2ND ST Ln yo C:) ul I i'to.% 185 no 2/OP 1/0 65*T STA 2 4 4 346 3 351 365 4 375 4 31� 155 3J9 2-58 j/0T 395 T T 395 vo-f 1c)� 4 \ -IF--,A� CUE Reports Estimate Number:32507 349 2ND ST POLE INSTALL Estimate Type:SR Contractor:HENKELS&MCCOY ING Estimate Version: By: SIMPRB MWO#/Task:30239631 Required Date: Oracle Project#:8004473 Estimated On: 02/12/2018 Cost Estimate JEA Contractor Materials 1.New Material Cost(w/sales tax) $572.69 $572.69 2.Transformer Cost(wl sales tax) $0.00 $0.00 3.Returned Material Salvage Value $0.00 $0.00 Labor $309.62 $765.17 4.Crew Time $0.00 $0,00 5.Extraordinary Costs JEA Overhead $216.14 $116.68 6.Fringe Benefits(54.56%of lines 4&7) $86.54 $213,87 7.Engineering Costs(Variable%of line 4) $179.56 $0.00 8,Project Equipment Costs(40%of total equipment costs) 9.Material Handling(8.30%of lines 1 &2) $47.53 $47.53 10.Inspection(6.84%of line 4) $0.00 $52.34 11.Total Cost of Project $1,412.08 $1,768.28 12.Work Order Estimate(Line 11 minus line 8,9.&10) $1,184.99 $1.720.74 13.Billable Equipment Depreciation(60%of total equipment costs) $269.34 $0.00 14.Billing Estimate(Including Transformer Cost)(Lines 11 +13+(58.71%of 4&7)) $1,914.01 $1,893.84 15.Billing Estimate(W/O Transformer Cost)(Lines 11 +13+(58.71%of 4&7)-Line 2) $1,914.01 $1,893.84 Time Estimate Crew I-Igura Total ManhgUrs 2.48 9.93 ----------------------------------------------------------------------------------------------------------------------------------- J—E-A, CUE Reports Estimate Number:32507 349 2ND ST POLE INSTALL Estimate Type:SIR Contractor:HEN KELS&MCCOY INC Estimate Version: By: SIMPRB MWO#rTask:30239631 Required Date: Oracle Project M 8004473 Estimated On: 02/12/2018 CU Detail Build Transfer Remain in Place Kemove C.2/OP 60 G3W 1 G3W*2 1 GY3 1 GY3*5 1 P.35/4W 1 S4 1 S4*2/0 1 iA Build Transfer Remain in Place Remove RUBUP 4 S20ES 1 S20ES*4/0-2/0 1 S4 I S4*2/0 1 RUBDOWN 4 JGA' CUE Reports Estimate Number:32507 349 2ND ST POLE INSTALL Estimate I ype:SIR Contractor:HENKELS&MCCOY INC Estimate Version; By: SIMPRB MWO#/Task:30239631 Required Date: Oracle Project M 8004473 Estimated On: 02112/2018 Conductor, Conduit and Pipe Detail Quantities From Station To Station cu Build Transfer Remain Remove 01 2 C.2/OP 60 0 0 0 JEA CUE Reports Estimate Number:32507 349 2ND ST POLE INSTALL Estimate Type:SIR Contractor:HENKELS&MCCOY ING Estimate Version: By: SIMPRB MWO#/Task:30239631 Required Date: Oracle Project#:8004473 Estimated On: 02/12/2018 Material Summary Item Quantity Item Number Item Description 2 ANCSS002 ANCHOR, SCREW, SINGLE-HELIX, GALVANIZEb—io,i X 8'X 1-1/4", SHIP ON OPEN FLATBED ONLY! 2 Bo­LmS036 BOLT, MACHINE, 3/4"X 14", SQUARE HEAD GALVANIZED STEEL, W/SQUARE NUT ATTACHED, (MUST BE SHIPPED IN STD. BOX QUANTITIES OF 25 EACH) 60 CA10SO02 CABLE, 2/0 (PAP), OVERHEAD SERVICE DROP, 600 VOLT MULTIPLEX CABLE "MESA VERDE" PRE-ASSEMBLED PARALLEL SOUTHWIRE61- 28-96-1, 1500 FOOT REELS 2 CLAGRO01 CLAMP, GROUND ROD, 5/8"-4SOL"HAMMERLOCK" 1 CLASR002 CLAMP, STRAIN RELIEF WEDGE,ALUMINUM, 1/0 TRI-4/0 PAP I CLASR003 CLAMP, STRAIN RELIEF WEDGE MESSENGER, SIZE: #6-2/U 2 CLASS004 CLAMP, STRAIGHT STRAIN,ALUMINUM, 5000#,4-3/0 ALUM 6 CNNCP002 CONNECTOR, #2, 6-2 MAIN, 2-1/0 TAP,ALUMINUM COMPRESSION, PARALLEL TAP, NNCP004 CONNECTOR,#4, 1/0-2/0 MAIN, 1/0-3/0 TAP COMPRESSION, PARALLEL TAP,ALUMINUM, 3 CNNCP006 CONNECTOR,#6, 1/0-2/0 MAIN, 310-4/0 TAP COMPRESSION, PARALLEL TAP,ALUMINUM, 4 CNNVG003 CONNECTOR, 6-2 SOL/10-2 SOL, V18E GRIP PARALLEL, BRONZE 22 COBC0028 CONDUCTOR, #4 SOLID, SOFT DRAWN, BARE COPPER, 200', 25#, ON PLASTIC REEL,4"X 11.5"W/2" HOLE 140 COBCW014 CONDUCTOR,#4,TYPE 40 DSA, COPPERWELD& COPPERWELD- COPPER.204" DIAMETER 1480#BREAKING STRENGTH (50#COIL- 42T) 4 COVIC002 COVER,"D"DIE, INSULATING, 2-1/2" 2 GUAGWO01 GUARD, GROUND WIRE, 1/2"X 1/2"X 96", GRAY PLASTIC 2 GUAGWO02 GUARD, "YELLOW", GUY WIRE, 1/4"TO 1/2"8', POLYETHYLENE, USED ON ALL 3/8"AND 7/16"GUY STRANDS(DISTRIBUTION) 2 GUYAT008 GUY HOOK, COMBINATION, MALLEABLE OR DUC I ILE ]RON, HOT DIP GALV, 13/16" MOUNTING HOLE, 20,000 LB MIN. ULT. STRENGTH. FOR WOOD OR CONCRETE POLES 4 GUYGRO01 GRIP, GUY, 3/8", 26", GALVANIZED 100 GUYST005 STRAND, GUY, 3/8" DIA, 7 PER STRAND, GALVANIZED STEEL, CLASS "B"GALV. OR BEZINOL IS ACCEPTABLE (500- COIL) I INSGBOO2 INSULATOR, STRAIN, GUY B��E_AKER, 21,000#RATED, 60" ROD LENGTH, FIBERGLASS FOR USE ON JEA'S DISTRIBUTION SYSTEM ONLY 4 INSSU002 INSULATOR, SUSPENSION,4", CLASS 52-9 NEMA STRENGTH 10000#, GALV, FITTINGS 1 POLWO003 POLE,WOOD, 35-CLASS 4 (T/L=44),WEIGHT=1,026 LBS 2 RODGRO03 ROD,GROUND,THREADLESS, 5/8"X 8', SHIP ON OPEN FLA I 13LD ONLY! 1 TAGH0007 ALUMINUM VERTICAL TAG HOLDER FOR ADHESIVE BACK CHARACTERS((NOT FOR"SLIDE IN"CHARACTERS)). 19.5" HIGH X 2" WIDE WITH 3-1/8" NAIL HOLES @ THE TOP AND THE BOTTOM. (PKG. OF 50 EACH) 2 WASRD005 WASHER, ROUND, 3/4" BOLT SIZE X 2" DIAMETER, GALVANIZED, A-6/11. CUE Reports Estimate Number:32507 349 2ND ST POLE INSTALL Estimate Type:SIR Contractor:H ENKELS&MCCOY INC Estimate Version: By: SIMPRB MWO#/Task:30239631 Required Date: Oracle Project M 8004473 Estimated On: 02/12/2018 500 EACH PER BOX 2 WASSF003 WASHER, SQUARE FLAT, 3" SQ X 1/4", 5/8"X 3/4"BOLT SIZE, GALVANIZED 2 WASSP002 WASHER, SPRING, 3/4"BOLT SIZE, DOUBLE COIL HELICAL TYPE, GALVANIZED (EXTRA HEAVY DUTY) JG11 CUE Reports Estimate Number:32507 349 2ND ST POLE INSTALL Estimate Type:SR Contractor:HENKE LS&MCCOY INC Estimate Version: By: SIMPRB MW O#/Task:30239631 Required Date: Oracle Project#:8004473 Estimated On: 02/12/2018 CU Summary �0 .1 IfflMr , W,I U." 'I OR MI .,WINIR 'tdAame Quantity Description C.2/OP 60 2/0 AAC PAP W/2/0 AAAC NEUTRAL G3W*2 1 WOOD POLE-NON-EQUIPMENT GROUND GY3*5 1 GY3*5 3/8" DOWNGUY W/8 FT SCREW ANCHOR P.35/4W 1 35 FT. CLASS 4 WOOD POLE RUBUP 4 LINE RUBBER INSTALLATION, PER SECT. S20ES I SECONDARY CONNECTION AT POLE S20ES*4/0-2/0 1 SECONDARY CONNECTION AT POLE S4*210 2 SECONDARY DEADEND ,Mv� !! "A, v, �IZ A" 'IMN WN M, 'I's' CV Nam Quantity DescriRtion RUBDOWN 4 LINE RUBBER REMOVAL, PER SECT. FEB 1 2 2018 CITY OF ATLANTIC BEACH CONSTRUCTION PERMIT WITHIN CITY RIGHTS OF WAY AND EASEMENTS 800 Seminole Road 904-247-5800 Atlantic Beach,Florida 32233-5445 Fax 904-247-5845 PLEASE SUBMIT(3)COMPLETE SETS OF PLANS WITH APPLICATION, Date z, IT# PERM C) P0 C) D BY THE CITY Job Address— 7- Permitee: J4 Telephone# 2 Permittee Address: 1- 64 u" 's i-, Requesting Permission to Construct: Pd Location: (Reference to Cross-Street) S h ern� 02� 1. Applicant declares that prior tofiling this application he has ascertained the location of all existing utilities, both aerial and underground and the accurate locations are shown on the sketches. A Letter of Notification was mailed to the following Utilities/Municipalities: Jacksonville Electric Authority Yes( No Date: Bell South Telephone Company Yes( No Date: Ferrell Gas Yes No Date: Comcast Yes No Date: 2. Whenever necessary for the construction, repair, improvement; maintenance, safe and efficient operation, alteration or relocation of all,or any portion of said street or easement as determined by the Director of Public Works, any or all of said poles, Wires, pipes, cables or other facilities and appurtenances authorized hereunder, shall be immediately removed from said street or easement or reset or relocated hereon as required by the Director-of Public Works, and at the expense of the Permittee unless reimbursement is authorized. 3. All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed under the supervision of A—/1�,q V, (Contractors Project Superintendent)located at Telephone#: (a/ 4. All materials and equipment shall be subject to inspebtion by the Director of Public Works or his designee. 5. All city property shall be restored to its original condition as far as practical, in keeping with city specifications and the manner satisfactory to the city. 6. A sketch of plans covering details of this installafion, as well as, a copy of a recent survey shall be made a part of this permit. Calculations showing any increase in impervious area on owner's lot or in the citV Right of Way are to be included with this application. 7. This permittee shall commence actual construction in good faith with W days. If the beginning date is more than 60 days from date of permit approval, then permittee must review the permit with the Director of Public Works to make sure no changes have occurred in the area that would affect the permitted construction. 8. It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right, title and interest in the land to be entered upon and used by the holder, and the Holder will, at all times, assume all risk of and indemnify, defend, and save harmless the City of Atlantic Beach from and against any and all loss, damage, and cost of expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges. 9. The Director of Public Works shall be notified twenty-four (24) hours prior to starting work and again immediately upon completion. OWNER Signed: Date:. Before me this day of In the County of Duval. State Of Florida,has personally appeared_ -_ Notary Public at Large,State of Florida,County of Duval, My commission expires; Personally Known: Produced Identification: