353 2nd St ROW permit �p
11 it CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
19' INSPECTION PHONE LINE 247-5814
RIGHT OF WAY - SINGLE OR TWO FAMILY RIGHT OF WAY
MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814
PERMIT INFORMATION:
PERMIT NO: ROW1 8-0004
Description: install 35-foot wood pole in right of way
Estimated Value: 0
Issue Date: 2/22/2018
Expiration Date: 5/23/2018
PROPERTY ADDRESS:
Address: 353 2ND ST
RE Number: 1697860000
PROPERTYOWNER:
Name: JOHNSONJOANN
Address: 181 PROCTORS PURCHASE RD
HARTLY, DE 19953
GENERAL CONTRACTOR INFORMATION:
Name:
Address:
Phone:
Name: JACKSONVILLE ELECTRIC AUTHORITY
Address: 21 CHURCH ST W 3RD FLR
JACKSONVILLE, FL 32202
Phone:
PERMIT INFORMATION:
Please see attached conditions of approval.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB
SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY
BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions
applicable to this property that may be found in the public records of this county, and there may
be additional permits required from other governmental entities such as water management
districts, state agencies, or federal agencies.
* A notice of Commencement is only required for work exceeding an estimated value of
$2,500. For HVAC work, a Notice of Commencement is only required when HVAC work
exceeds and estimated value of$7,500.
APPLICATION NUMBER
City of Atlantic Beach
Building Department (To be assigned by the Building Department.)
r-hEIVE -
;01 800 Seminole Road
V C)W
.x Atlantic Beach, Florida 32233-5445
Phone (904)247-5826 - Fax(904)247-58F!EB 16 2018
E-mail: building-dept@coab.us ) - L Date routed: It
City web-site: http-://www.coab.us Li
APPLICATION REVIEW AND TRACKING FORM
Property Address: "d �Sq Department review required Yes No
Building
Applicant: Planning &Zoning
Tree Administrator
"Oj CV_ubfic V___r
Project: k o j�?
(.Public Utili��s
Public Safety
Fire Services
Review fee Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
� of Permit Verified By
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St.Johns River Water Management District
Army Corps of Engi-neers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: MApproved. E]Denied. [-]Not applicable
(Circle one.) Comments:
BUILDING
PLANNING &ZONING Reviewed by�_f
Date:-,z —J/
TREE ADMIN. Second Review: ElApproved as revised. OlDenied. E]Not applicable
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: DApproved as revised. [—]Denied. E]Not applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017
City of Atlantic Beach APPLICATION NUMBER
-E C E I V E (To be assigned by the Building Department.)
Building Department
800 Seminole Road 00tt
Atlantic Beach, Florida 32233-5445 C)w
Phone(904)247-5826 - Fax(904)2 4 7-49B 2018
E-mail: building-dept@coab.us te routed:
L_�a
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: Department review required Yes No
Building
Applicant: t�, A Planning &Zoning
Tree Administrator
Project: L f) "'-j � -
_Public Utiqg>
Public Safety
Fire Services
Review fee $ Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St.Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPL,14:�ATION STATUS
Reviewing Department First Review: [/Approved. []Denied. E]Not applicable
(Circle one.) Comments:
BUILDING 21- Z
PLANNING & ZONING Reviewed by: Date:
TREE ADMIN. Second Review: E]Approved as revised. F]Denied. Not applicable
PeUWORKS gommepts:
B �T.�r IT I E
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: []Approved as revised. E]Denied. ONot applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017
343
353
365
j
S".qFVWR I ATFRAI
8" PVC WATER MAIN]
340
348 34G
352
3G4
ENGINEERING DESIGN
ORACLE PERMIT MAXIMO DATE REL
PROJECT#:32507 N.C.: 8004473 WO#: 30239631 CONST 02112/18
CIR. TREE TRIMMING
SUB-STA NEPTUNE BEACH N.O.: 563 REQ'D:.YES
CELL
ENGINEER: Robert Simpson N.O.: NIA ZIP CODE: N/A
CUSTOMER/ Svc PHONE
LOCATION: 353 2ND STJ POLE INSTALLATION 563 Sssc N.O.:665-7793
CENTER.
STA 1. P# 349 2ND ST./ INSTALL 35/4W
POLE, RUN 210P TO STA 2.
3 ' D
STA 2. P#3,50 2ND ST,
EL-2018/00027.910 T'j uj
Ln Ln
Ln ON
THIS IS FOR A NEW HOME BUILT 0-'j T
0 T
6 5-T 4T T STA 1
390
1* 350
370 360 345
3g4 390-1 3 2 35� 343
-265 3 0 367 3�3 4
50A 377 3V
'*.Ull 4
't r'j
393 I/0-f
-6C
4CU
2ND ST
Ln yo
C:) ul
I i'to.% 185 no 2/OP 1/0
65*T
STA 2 4
4 346
3
351
365 4
375 4
31�
155 3J9
2-58
j/0T
395 T T
395 vo-f
1c)� 4 \
-IF--,A� CUE Reports
Estimate Number:32507 349 2ND ST POLE INSTALL Estimate Type:SR Contractor:HENKELS&MCCOY ING
Estimate Version: By: SIMPRB
MWO#/Task:30239631 Required Date:
Oracle Project#:8004473 Estimated On: 02/12/2018
Cost Estimate JEA Contractor
Materials
1.New Material Cost(w/sales tax) $572.69 $572.69
2.Transformer Cost(wl sales tax) $0.00 $0.00
3.Returned Material Salvage Value $0.00 $0.00
Labor $309.62 $765.17
4.Crew Time $0.00 $0,00
5.Extraordinary Costs
JEA Overhead $216.14 $116.68
6.Fringe Benefits(54.56%of lines 4&7) $86.54 $213,87
7.Engineering Costs(Variable%of line 4) $179.56 $0.00
8,Project Equipment Costs(40%of total equipment costs)
9.Material Handling(8.30%of lines 1 &2) $47.53 $47.53
10.Inspection(6.84%of line 4) $0.00 $52.34
11.Total Cost of Project $1,412.08 $1,768.28
12.Work Order Estimate(Line 11 minus line 8,9.&10) $1,184.99 $1.720.74
13.Billable Equipment Depreciation(60%of total equipment costs) $269.34 $0.00
14.Billing Estimate(Including Transformer Cost)(Lines 11 +13+(58.71%of 4&7)) $1,914.01 $1,893.84
15.Billing Estimate(W/O Transformer Cost)(Lines 11 +13+(58.71%of 4&7)-Line 2) $1,914.01 $1,893.84
Time Estimate
Crew I-Igura Total ManhgUrs
2.48 9.93
-----------------------------------------------------------------------------------------------------------------------------------
J—E-A, CUE Reports
Estimate Number:32507 349 2ND ST POLE INSTALL Estimate Type:SIR Contractor:HEN KELS&MCCOY INC
Estimate Version: By: SIMPRB
MWO#rTask:30239631 Required Date:
Oracle Project M 8004473 Estimated On: 02/12/2018
CU Detail
Build Transfer Remain in Place Kemove
C.2/OP 60
G3W 1
G3W*2 1
GY3 1
GY3*5 1
P.35/4W 1
S4 1
S4*2/0 1
iA
Build Transfer Remain in Place Remove
RUBUP 4
S20ES 1
S20ES*4/0-2/0 1
S4 I
S4*2/0 1 RUBDOWN 4
JGA' CUE Reports
Estimate Number:32507 349 2ND ST POLE INSTALL Estimate I ype:SIR Contractor:HENKELS&MCCOY INC
Estimate Version; By: SIMPRB
MWO#/Task:30239631 Required Date:
Oracle Project M 8004473 Estimated On: 02112/2018
Conductor, Conduit and Pipe Detail
Quantities
From Station To Station cu Build Transfer Remain Remove
01 2 C.2/OP 60 0 0 0
JEA CUE Reports
Estimate Number:32507 349 2ND ST POLE INSTALL Estimate Type:SIR Contractor:HENKELS&MCCOY ING
Estimate Version: By: SIMPRB
MWO#/Task:30239631 Required Date:
Oracle Project#:8004473 Estimated On: 02/12/2018
Material Summary
Item Quantity Item Number Item Description
2 ANCSS002 ANCHOR, SCREW, SINGLE-HELIX, GALVANIZEb—io,i X 8'X 1-1/4", SHIP
ON OPEN FLATBED ONLY!
2 BoLmS036 BOLT, MACHINE, 3/4"X 14", SQUARE HEAD GALVANIZED STEEL,
W/SQUARE NUT ATTACHED, (MUST BE SHIPPED IN STD. BOX
QUANTITIES OF 25 EACH)
60 CA10SO02 CABLE, 2/0 (PAP), OVERHEAD SERVICE DROP, 600 VOLT MULTIPLEX
CABLE "MESA VERDE" PRE-ASSEMBLED PARALLEL SOUTHWIRE61-
28-96-1, 1500 FOOT REELS
2 CLAGRO01 CLAMP, GROUND ROD, 5/8"-4SOL"HAMMERLOCK"
1 CLASR002 CLAMP, STRAIN RELIEF WEDGE,ALUMINUM, 1/0 TRI-4/0 PAP
I CLASR003 CLAMP, STRAIN RELIEF WEDGE MESSENGER, SIZE: #6-2/U
2 CLASS004 CLAMP, STRAIGHT STRAIN,ALUMINUM, 5000#,4-3/0 ALUM
6 CNNCP002 CONNECTOR, #2, 6-2 MAIN, 2-1/0 TAP,ALUMINUM COMPRESSION,
PARALLEL TAP,
NNCP004 CONNECTOR,#4, 1/0-2/0 MAIN, 1/0-3/0 TAP COMPRESSION,
PARALLEL TAP,ALUMINUM,
3 CNNCP006 CONNECTOR,#6, 1/0-2/0 MAIN, 310-4/0 TAP COMPRESSION,
PARALLEL TAP,ALUMINUM,
4 CNNVG003 CONNECTOR, 6-2 SOL/10-2 SOL, V18E GRIP PARALLEL, BRONZE
22 COBC0028 CONDUCTOR, #4 SOLID, SOFT DRAWN, BARE COPPER, 200', 25#, ON
PLASTIC REEL,4"X 11.5"W/2" HOLE
140 COBCW014 CONDUCTOR,#4,TYPE 40 DSA, COPPERWELD& COPPERWELD-
COPPER.204" DIAMETER 1480#BREAKING STRENGTH (50#COIL-
42T)
4 COVIC002 COVER,"D"DIE, INSULATING, 2-1/2"
2 GUAGWO01 GUARD, GROUND WIRE, 1/2"X 1/2"X 96", GRAY PLASTIC
2 GUAGWO02 GUARD, "YELLOW", GUY WIRE, 1/4"TO 1/2"8', POLYETHYLENE, USED
ON ALL 3/8"AND 7/16"GUY STRANDS(DISTRIBUTION)
2 GUYAT008 GUY HOOK, COMBINATION, MALLEABLE OR DUC I ILE ]RON, HOT DIP
GALV, 13/16" MOUNTING HOLE, 20,000 LB MIN. ULT. STRENGTH. FOR
WOOD OR CONCRETE POLES
4 GUYGRO01 GRIP, GUY, 3/8", 26", GALVANIZED
100 GUYST005 STRAND, GUY, 3/8" DIA, 7 PER STRAND, GALVANIZED STEEL, CLASS
"B"GALV. OR BEZINOL IS ACCEPTABLE (500- COIL)
I INSGBOO2 INSULATOR, STRAIN, GUY B��E_AKER, 21,000#RATED, 60" ROD
LENGTH, FIBERGLASS FOR USE ON JEA'S DISTRIBUTION SYSTEM
ONLY
4 INSSU002 INSULATOR, SUSPENSION,4", CLASS 52-9 NEMA STRENGTH 10000#,
GALV, FITTINGS
1 POLWO003 POLE,WOOD, 35-CLASS 4 (T/L=44),WEIGHT=1,026 LBS
2 RODGRO03 ROD,GROUND,THREADLESS, 5/8"X 8', SHIP ON OPEN FLA I 13LD
ONLY!
1 TAGH0007 ALUMINUM VERTICAL TAG HOLDER FOR ADHESIVE BACK
CHARACTERS((NOT FOR"SLIDE IN"CHARACTERS)). 19.5" HIGH X 2"
WIDE WITH 3-1/8" NAIL HOLES @ THE TOP AND THE BOTTOM. (PKG.
OF 50 EACH)
2 WASRD005 WASHER, ROUND, 3/4" BOLT SIZE X 2" DIAMETER, GALVANIZED,
A-6/11. CUE Reports
Estimate Number:32507 349 2ND ST POLE INSTALL Estimate Type:SIR Contractor:H ENKELS&MCCOY INC
Estimate Version: By: SIMPRB
MWO#/Task:30239631 Required Date:
Oracle Project M 8004473 Estimated On: 02/12/2018
500 EACH PER BOX
2 WASSF003 WASHER, SQUARE FLAT, 3" SQ X 1/4", 5/8"X 3/4"BOLT SIZE,
GALVANIZED
2 WASSP002 WASHER, SPRING, 3/4"BOLT SIZE, DOUBLE COIL HELICAL TYPE,
GALVANIZED (EXTRA HEAVY DUTY)
JG11 CUE Reports
Estimate Number:32507 349 2ND ST POLE INSTALL Estimate Type:SR Contractor:HENKE LS&MCCOY INC
Estimate Version: By: SIMPRB
MW O#/Task:30239631 Required Date:
Oracle Project#:8004473 Estimated On: 02/12/2018
CU Summary
�0 .1 IfflMr , W,I
U."
'I OR
MI .,WINIR
'tdAame Quantity Description
C.2/OP 60 2/0 AAC PAP W/2/0 AAAC NEUTRAL
G3W*2 1 WOOD POLE-NON-EQUIPMENT GROUND
GY3*5 1 GY3*5 3/8" DOWNGUY W/8 FT SCREW ANCHOR
P.35/4W 1 35 FT. CLASS 4 WOOD POLE
RUBUP 4 LINE RUBBER INSTALLATION, PER SECT.
S20ES I SECONDARY CONNECTION AT POLE
S20ES*4/0-2/0 1 SECONDARY CONNECTION AT POLE
S4*210 2 SECONDARY DEADEND
,Mv�
!!
"A,
v,
�IZ A"
'IMN
WN
M, 'I's'
CV Nam Quantity DescriRtion
RUBDOWN 4 LINE RUBBER REMOVAL, PER SECT.
FEB 1 2 2018
CITY OF ATLANTIC BEACH
CONSTRUCTION PERMIT WITHIN CITY RIGHTS OF WAY AND EASEMENTS
800 Seminole Road 904-247-5800
Atlantic Beach,Florida 32233-5445 Fax 904-247-5845
PLEASE SUBMIT(3)COMPLETE SETS OF PLANS WITH APPLICATION,
Date z, IT#
PERM C) P0 C)
D BY THE CITY
Job Address— 7-
Permitee: J4 Telephone# 2
Permittee Address: 1- 64 u" 's i-,
Requesting Permission to Construct: Pd
Location: (Reference to Cross-Street) S h ern� 02�
1. Applicant declares that prior tofiling this application he has ascertained the location of all existing utilities,
both aerial and underground and the accurate locations are shown on the sketches.
A Letter of Notification was mailed to the following Utilities/Municipalities:
Jacksonville Electric Authority Yes( No Date:
Bell South Telephone Company Yes( No Date:
Ferrell Gas Yes No Date:
Comcast Yes No Date:
2. Whenever necessary for the construction, repair, improvement; maintenance, safe and efficient operation,
alteration or relocation of all,or any portion of said street or easement as determined by the Director of Public
Works, any or all of said poles, Wires, pipes, cables or other facilities and appurtenances authorized
hereunder, shall be immediately removed from said street or easement or reset or relocated hereon as
required by the Director-of Public Works, and at the expense of the Permittee unless reimbursement is
authorized.
3. All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be
performed under the supervision of A—/1�,q V, (Contractors Project
Superintendent)located at Telephone#: (a/
4. All materials and equipment shall be subject to inspebtion by the Director of Public Works or his designee.
5. All city property shall be restored to its original condition as far as practical, in keeping with city specifications
and the manner satisfactory to the city.
6. A sketch of plans covering details of this installafion, as well as, a copy of a recent survey shall be made a
part of this permit. Calculations showing any increase in impervious area on owner's lot or in the citV
Right of Way are to be included with this application.
7. This permittee shall commence actual construction in good faith with W days. If the beginning date is
more than 60 days from date of permit approval, then permittee must review the permit with the Director of
Public Works to make sure no changes have occurred in the area that would affect the permitted construction.
8. It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the
City's right, title and interest in the land to be entered upon and used by the holder, and the Holder will, at all
times, assume all risk of and indemnify, defend, and save harmless the City of Atlantic Beach from and
against any and all loss, damage, and cost of expenses arising in any manner of the exercise or attempted
exercises by the holder of the aforesaid rights and privileges.
9. The Director of Public Works shall be notified twenty-four (24) hours prior to starting work and again
immediately upon completion.
OWNER
Signed: Date:.
Before me this day of In the County of Duval.
State Of Florida,has personally appeared_ -_
Notary Public at Large,State of Florida,County of Duval,
My commission expires; Personally Known:
Produced Identification: