369 10th St RES19-0329 Envelope Leakage TestTesting Company: Name:Indoor Comfort Consulting Inc. Address:4040 Julington Creek Rd Jacksonville , FL 32223 Phone: 904-219-7309 Technician: Name:Howard Stalls Credentials:CAC057409 Email:howard@iccjax.com Building Information: Project ID:Ayers Address:369 10TH Street Atlantic Beach, FL 32233 Geo-Tag Data:Latitude: Longitude: Timestamp: Customer Information: Name:McAneny Builders Address:650 Park Street Jacksonville, FL 32204 Measured Leakage:1.10 ACH50 Test ID:# 1 Purpose of Test:50 Pa Env. Leakage Measured CFM50:534.2 Effective Leakage Area: 29.4 in² Building Volume:29,138.0 ft³Enclosure Surface Area: 3,835.0 ft² Coefficient (C):42.0 Exponent (n): 0.650 (assumed) Test Standard:RESNET 380 One-Point Test Mode: Depressurize Test Characteristics:Indoor Temp: 74 °F Altitude: 10.0 ft Outdoor Temp: 75 °F Time Average Period: 10 seconds Test Date and Time:2020-10-22 16:44:17 Envelope Leakage Test Test Readings: Target (Pa)Bldg (Pa)Adj Bldg (Pa)Fan (Pa)Flow (cfm)Config Baseline 0.7 -50.0 -49.4 -50.1 -79.9 531.7 Ring B Test Equipment: Flow Device:Model 3 110V Fan Serial #: 5515 Pressure Gauge:DG1000 Serial #: 5515 Calibration Date: 2020-03-19 Deviations from Standard: None Comments: None Envelope Leakage Test Page 2 of 2Report by TEC Auto Test 1.7.3 (91), © 2020 The Energy Conservatory, Inc.