2321 Mayport Rd 9-10-2020 fire system inspection results rwrP FORTITUDE FIRE PROTECTION --® 2430 University Blvd. West * Jacksonville, FL 32217 * 904-733-9008 www.fortitudefire.com Good Afternoon Please find the enclosed inspection reports for your area. If you have any questions, have received in error or need further information please give me a call at 904-733-9008 or email me at stephanie@fortitudefire.corn Thank you and have a great day. Stephanie Peiker Vice President rr FDR ITUD FIRE PROTECTION 2430 University Blvd W.* Jacksonville,FL 32217 * 904-733-9008 www.fortitudefire.com Wet System / 5 Year Inspection / Internal Pipe Field Report Customer: Dollar Tree#5993 Date: 9/10/2020 Site Name: Same Phone: (904) 241-2110 Site Address: 2321 Mayport Rd. Atlantic Beach Florida 32233 InsActi6q.gm valves and their associate strainers,filters and restriction orifices passed internal inspection? ❑Yes ❑No Q N/A B. Check valves internally inspected and all parts operate properly,move freely and are in good condition? Q Yes No ❑ N/A Testing_ A. Sprinklers rated above high temperature tested? ❑ Yes ❑ No Q N/A B. Gauges checked by calibrated gauge or replaced? Q Yes ❑ No ❑ N/A ❑� Replaced ❑Calibrated C. Pressure reducing valves passed full flow test? ❑ Yes ❑ No N/A • Internally inspect all wet pipe alarm valves. Verify that all components operate properly,move freely and are in good condition. • Internally inspect all check valves. Verify that all components operate properly,move freely and are in good condition. • Examine the internal condition of various sections of the sprinkler piping system to determine if they are free of obstructions. • Remove a representative sample of solder type sprinklers with temperature classification of Extra High(325')or greater that are located in an area in which they are exposed to semi-continuous to continuous maximum allowable ambient conditions. • Replace all gauges older than five(5)years. Type of System: Wet Straight pipe Riser Location: Left corner of stockroom # of Branches Examined: 2 Comments: Stockroom # of Cross Mains Examined: 2 Comments: Stockroom # of Alarm Valves Examined: 0 Comments: Other Points Examined: Comments: Deficiencies Noted: Seal #0003950 **Please indicate below the size if the pipes examined,the locations and the amount of debris found in the pipes:** Size: 1.5" 1.5" 3" 3" ear t/Debris Clear/ Debris Debris Clear/i Debris 4110 Pipe Location: Stockroom Stockroom Stockroom Stockroom Technician Name: TJ Racer Customer Name: Laura Johnson Technician Signature: Customer Signature: Lir Technician License#: FPI18-000295 Color of tag placed on system: ❑RED ['GREEN 0 YELLOW •...,„4, ,t. ,.111, d sAillir'.. ..2_14...t", . ° .'• ' ' ,i''.. Alb t., -. . . ,.. '... • .,,,,„, „... 13, , ._ Air OP _ .. . , 4 ., , \ i oitifk ( .I. ...0.- i or • . . * .....--