362 Plaza RES17-0079 ZRC 06.28.2017 Date: 6/28/2017 Permit: RES17-0079 Applicant: CBI Construction Review: ZONING Address: 5472 First Coast Hwy Ste 6, Ferdinanda Beach Site Address: 362 PLAZA Phone: 302-8606 RE#: 169972 0005 Email: Richard.merriam@abott.com Correction Comments 1. Height: Section 24-17 requires height to be measured from grade to the highest point of a building’s roof structure or parapet and any attachments thereto, exclusive of chimneys. Please show the overall height on plans. 2. Shade Trees: Section 24-172(c)(4) requires 2 shade trees to be located on the property as part of the Old Atlantic Beach Design Standards. One of the trees must be located within the front yard. This is the area within 20 feet of the property line along the street. The second tree can be located anywhere else on the lot. See Section 23-33(f)(f) for a list of approved shade tree species. 3. Setbacks: Section 24-67(c) requires a site plan showing setbacks. Please provide a site plan showing setbacks from all new elements to property lines. 4. Side Walls Length: Section 24-172(c)(1) requires that second floor side walls be no longer than 35 feet in length without an architectural offset in the wall. A second floor side wall exceeds 35 feet in length. Please revise plans accordingly. 5. Side Yard Projections: Section 24-83(b) limits side yard projections into side yard setbacks, including roof overhangs, to 24”. Please show that this requirement is being met or revise plans accordingly. Informational Comments Brian Broedell Planner ZONING REVIEW COMMENTS City of Atlantic Beach Community Development Department 800 Seminole Road Atlantic Beach, Florida 32233-5445