1765 Selva Marina Drive RES18-0357 ZRC 11.01.2018 CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
(904) 247-5800
ZONING REVIEW COMMENTS
Date: 11/1/2018
Permit #: RES18-0357 Site Address: 1765 SELVA MARINA DR
Review Status: DENIED RE#: 172018 0000
Applicant: Mitch Taylor Master Builder, LLC Property Owner: CLINE CHRISTOPHER T
Email: mt@mtmasterbuilder.com Email: ctcline@outlook.com
Phone: 9047164778
Phone:
THIS REVIEW IS ONE OF MULTIPLE DEPARTMENT REVIEWS.
Revisions may not be submitted until ALL departments have completed their respective reviews.
Revisions submitted MUST respond to EACH department review. Submittals that respond to only one or a
few correction items will not be accepted.
Correction Comments:
Average Grade: Section 24-17 states "The calculated average grade shall be used for determination of the
maximum allowable height of building on parcels that have topographical variation of more than two (2) feet
as demonstrated by a certified topographical survey and for all oceanfront parcels. This average elevation shall
be determined by the mathematical average of elevation points dispersed at approximately ten -foot
equidistant intervals across the buildable area of a parcel. For sites where natural topography has been
previously altered or where existing structures remain, the same method shall be used excluding areas where
existing structures remain. Where required, the certified Calculated Average Grade Survey shall be submitted
with Construction Plans, and the Calculated Average Grade shall be depicted on all exterior elevation sheets of
the Construction Plans.
Height: Section 24-17 requires overall height to be measured from average grade for proposed structures on
lots with more than two feet of topographical variation.
Pool Cabana: Sheet L3 shows a pool cabana, if the pool cabana is part of this permit please provide
construction plans.
Resubmittal Notes:
All revisions and changes shall clearly stand out from the rest of the drawing on the sheet as a revision by way of
completely encircling the change with “clouding”. The revision shall also be identified as to the sequence of revision by
indicating a triangle with the revision sequence number within it and located adjacent to the cloud. The revision date
and revision sequence number shall also be indicated in a conspicuous location in the title block for each sheet on which
a revision for that sequence occurs. For projects still in the initial review stage and permit pending, all sheets with
revisions shall be inserted into each set of drawings. The original sheets must be clearly marked “VOID” but are to be left
within the set of drawings. Complete new sets of drawings will not be accepted. ADDITIONAL ITEMS MAY BE REQUIRED
DEPENDING UPON NEW INFORMATION AND CLARITY OF FINAL PLANS SUBMITTED FOR REVIEW.