102 Aquatic Drive 16-SFAT-1793 ZRC 08.22.2016
Date: 8/19/16
Permit: 16-SFAT-1793 to
1798, 1801
Applicant: Tribridge Residential Construction
Review: 1st Address: 1575 Northside Dr NW, Bldg 100, Atlanta, GA 30318
Site Address: 102 Aquatic Drive Phone: (404) 367-6008
RE#: 177603-0000 Email: davidw@tbrs.com
Correction Comments
1. Height: Section 24-17 requires height to be measured from grade to the highest point of a building’s
roof structure or parapet and any attachments thereto, exclusive of chimneys. This project is within a
FEMA designated special flood hazard area so finish floor elevation should be used as the starting point
of measurement. Please show the overall height on plans. Note that the maximum allowable height is
35 feet.
2. Yard Projections: Section 24-83(b) limits side yard projections into side yard setbacks, including roof
overhangs, to 24”. Please show that this requirement is being met or revise plans accordingly.
3. Site Plan: Section 24-67(c) requires site plan showing setbacks. The site plan provided as part of the
civil permitting differs from the buildings shown in the architectural plans. This was specifically
observed in the size and location of exterior porches. Please provide a revised site plan with setbacks
shown so changes can be verified to meet code requirements.
Derek W. Reeves
Planner
dreeves@coab.us
ZONING REVIEW COMMENTS
City of Atlantic Beach
Community Development Department
800 Seminole Road Atlantic Beach, Florida 32233-5445
Phone: (904) 247-5826 Fax: (904) 247-5845 Email: dreeves@coab.us