225 S Nautical RERF20-0241 Permit PacketOWNER:ADDRESS:CITY:STATE:ZIP:
THOMES CHRISTINE A 225 NAUTICAL BLVD S ATLANTIC BEACH FL 32233-4120
COMPANY:ADDRESS:CITY:STATE:ZIP:
PIMENTEL ROOFING INC 402 St. Augustine Blvd.JACKSONVILLE
BEACH FL 32250
TYPE OF
CONSTRUCTION:
REAL ESTATE
NUMBER:ZONING:BUILDING USE
GROUP:SUBDIVISION:
170703 0382 SEASPRAY
JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK:
225 S NAUTICAL BLVD REROOF SHINGLE SHINGLE ROOF $11400.00
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
BUILDING PERMIT 455-0000-322-1000 0 $110.00
STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00
TOTAL: $114.00
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN
YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT
MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU
INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT.
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
1 of 2Issued Date: 12/29/2020
PERMIT NUMBER
RERF20-0241
ISSUED: 12/29/2020
EXPIRES: 6/27/2021
REROOF SHINGLE PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
2 of 2Issued Date: 12/29/2020
PERMIT NUMBER
RERF20-0241
ISSUED: 12/29/2020
EXPIRES: 6/27/2021
REROOF SHINGLE PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
DESCRIPTION ACCOUNT QTY PAID
PermitTRAK $114.00
RERF20-0241 Address: 225 S NAUTICAL BLVD APN: 170703 0382 $114.00
BUILDING $110.00
BUILDING PERMIT 455-0000-322-1000 0 $110.00
STATE SURCHARGES $4.00
STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00
TOTAL FEES PAID BY RECEIPT: R14456 $114.00
Printed: Tuesday, December 29, 2020 8:51 AM
Date Paid: Tuesday, December 29, 2020
Paid By: PIMENTEL ROOFING INC
Pay Method: CREDIT CARD 408458214
1 of 1
Cashier: CG
Cash Register Receipt
City of Atlantic Beach
Receipt Number
R14456
~+; CENTRALSQUARE
RERF20-0241
~~--------.:a--. ...,.... __ -
~ Building Permit Application
€ _~)1 City of Atlantic Beach Building Department
,,_~ 800 Seminole Road, Atlantic Beach, FL 32233
Phone: (904) 247-5826 Email: Building-Dept@coab.us
Updated 10/9/lB
OALL INFORMATION
HIGHLIGHTED IN GRAY
IS REQUIRED.
Job Address: J ;l5 N Ct.u.-heg, l B )v A S . f\:H4'-t\,e-~b 5-Z"2.-::;)~ermit Number: ________ _
Legal Description 55-l,L/ 11-~s'-;>.Ct-£ s~;er--ety Lof:: <3 ~,K 4 RE# /707 ()3-Oz'Fcr
Valuation of Work (Replacement Cost)$ / { ,I LJ O V Heated/Cooled SF ____ Non-Heated/Cooled _____ _
• Class of Work: □New □Addition □Alteration .01fepair □Move □Demo □Pool □Window/Door
• Use of existing/proposed structure(s): □Commercial Et'lfesidential
• If an existing structure, is a fire sprinkler system installed?: □Yes □No
• Will tree{sl be removed in association with orooosed nroiect? □Yes <must submit seoarate Tree Removal Permitl ~o
Describe in detailthe type of work to be performed: I -6t.v-b.f,f-~ re -v-o of-w J ~-I\-. "'-~ e,-l AY ~,t--
.-(:~ JI._ 4--~"' ~"'· "') ( t-
Florida Product Approval #~f_L_I_O~/ ~--'--'Y,_·....,/~,....;.11+/-t-~P_L __ z~5_t,~7_K~/-b ___ for multiple products use product approval form
Property Owner Information
N_ame ur:as+,,,e. A?Prn~S
City li 1'4-i:the.--~ ~tate Fl.-
Address ;>~S: NA-u+u:,d ~/vJ~. A,B-'FL 32.233
~ip .3:Z.2-33 Phone CJP'f:J.fcr--£/15
E-Mail ________________________________________ _
Owner or Agent (If Agent, Power of Attorney or Agency Letter Required) ___________________ _
Contractor lnformat·
Name of Company Qualifyirg Agent R et y ? I 1\1 en +e I
Address 2-. --:-.---i-...!..:..!,ir=--'-'-~-,,...,c..-'----""-"'--'--'~t-~-=;::..L>.."'""'"'--City Jt,.../(. #9?b, State Ft-Zip 3 Z 2 £0
Office Phone 'fO~ $",/ '1 S" Job Site Contact Number ![bl-f 5~ l 5'1-/°1 ¥'.'
State Certification/Registration #C.C.C I 220185 E-Mail p,M~~ l rp~1Y1 '1 e q t'k..tl j l 'CO-M
Architect Name & Phone# _________________________________ _
Engineer's Name & Phone# _________________________________ _
Workers Compensation Insurer _______________ OR Exempt □ Expiration Date _______ _
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or i nstallation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS,
WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. NOTICE: In addition to the requirements of this
permit, there may be additional restrictions applicable to this property that may be found i n the public records of th is county, and
there may be additional permits required from other governmental entities such as water management districts, state agencies, or
federal agencies.
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, co~~,,,~.~N:,." I H YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING V NO ICE O CEMENh,,-i ~
Signed and sworn to (or affirmed) before e this )L day of
_.()t,q M\_'f, _, ~~ J by--=--------r-----
J] Personally Known OR
[ l Produced !den~ification
Type of Jdent1ficat1on: _____________ _
~ (S1~~
Signed and sworn to (or affirmed) before me this J1_ day of ~ ~p{)'.NiJ,l ,.,-'<Jr') , b;.,-,r----+J------
Iii Personally Known OR
I ] Produced Identification
Type of Identification: -----------
RERF20-0241
8 NEMO(etc.
5.8 Tile Slippage Limitations (TAS 103 per FRSA/TRI April 2012 (04-12)):
When loading roof tiles on the underlayment in direct-deck tile assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles .
Underlayment
Lastobond TU HT
Co lphene FR GR
TABLE 3: TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS
Tile Profile
Flat
Lugged
Lugged
Flat
Lugged
Staging Method
Max. 10-tile stack
Max. 10-tile stack
Max. 10-tile stack (bottom 2-tile stack shall be inverted,
followed by 8 tiles high on slope, as shown below)
Maximum
Slope
6:12
5:12
6:12
6. INSTALLATION:
6.1
6.2
6.3
Soprema Roof Underlayments shall be installed in accordance with Soprema published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application, and prime the substrate with Elastocol Stick, Elastocol Stick Zero or RESISTO
EXTERIOR PRIMER (if applicable).
Lastobond TU HT, Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT,
Lastobond Pro HT-S, EnviroShield, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond Eco, Lastobond
Smooth Seal HT, Grip-Rite Smooth Seal HT, RESISTO LB1236, Grip-Rite Eave & Valley Protector, RESISTO LB1244
or Colphene FR GR:
6.3.1 Non-Tile Applications:
Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 or
R905.l.l for the type of prepared roof covering to be installed, and Soprema published requirements.
6.3.2 Tile Applications (Lastobond TU HT or Colphene FR GR only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual for Self-Adhered Membrane, and Soprema
published requirements.
For mechanically fastened tile roofing over a 2-ply system, consisting of Base Sheet and Self-Adhered Membrane,
fastening of the ASTM D226, Type II base sheet shall be in accordance with Soprema requirements, but not less than
that the densities set forth in FRSA/TRI April 2012 (04-12), Table 1.
For foam-on tile applications (Lastobond TU HT only), reference is made to Section 5.6.5 herein for wind resistance
limitations that fall outside the scope of FRSA/TRI April 2012 (04-12).
Ti le shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. See
Table 3 herein, and Soprema published requirements for tile staging.
NEMO ETC, LLC
Certificate of Authorization #32455 5TH EDITION (2017) FBC NON-HVH2 EVALUATION
Soprema Roof Underlayments
Evaluation Report S18010.06.09-R1S
FL2569·Rl7
Revision 1S: 06/19/2019
Page 7 of 8
RERF20-0241_i (J \ (L1
~,'J-'{~32)~ R yv (}<: ~NEMO!etc .
• , -4-.3--H-,P-&_R_IO_G_E_S_Ht_N_G_LE-s.-· ------------------------------..C...-~I
4.3.1 Seal -A-Ridge ® Ridge Cap Shingles, Seal-A-Ridge ® ArmorShie ld"' Ridge Cap Shingles and Timbertex ® Premium Ridge
Cap Shingles are fiberglass reinforced , hip and r id ge as phalt roof shingl es.
-
5. LIMITATIONS:
5.1 This is a building code eva lu ation . Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which th is Eva lu at ion Report, or previous versions thereof, is/was used for perm itting
or design gu id ance unless reta in ed specifically for that purpose.
5.2 This Eva luation Report is not for use in FBC HVHZ jurisd ictions.
5.3 Fire Classification is not part of this Eva luation Report; refer to current Approved Roofing Materia l s Directory for
fire ratings of this product.
5.4 Wind Classificat io n:
5.4.1 The GAF asphalt sh in gles noted in Sect ion 4.2 are Class ified in accordance with FBC Tables 1507.2.7.1 and
R90S.2.6.1 to ASTM D3161, Class F and/or ASTM 07158, Class H, in dicating the shing les are acceptable for use in
all wind zones up to Vasct = 150 mph (Vu it = 194 mph). Refer to Sect ion 6 for installation requirements to meet this
wi nd rating.
Note: Classi fication by ASTM D7158 applies only to expos ure category B or C, as defined in FBC 1609.4.3, and a
mean roof height of 60 f eet or less . Calculations by a qualified design profess ion al are required for conditions
outside these lim itations . Contact the sh in gle manufacturer for data spec ific to each sh in gle.
5.4.2 The GAF hip & ridge sh in gles noted in Section 4.3 are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM 03161, Class F, indicating the shingles are acceptable for use in all wind zones up to Va,d = 150
mph (Vu1 t = 194 mph). Refer to Section 6 for ins ta lla tion requirements to meet this wind rat ing .
5.5 All products in t he roof assemb ly shal l have qua li ty assu rance audit in accordance with F.A.C. Rule 61G20-3.
-GhMifulfU
@=GENERAL:
6.1.1 Roof deck, slope, underlayment and fasteners shall comply w ith FBC 1507.2 / R905.2 and t he shing le manufacturer's
minimum requirements.
6.1.2 Under lay m ent shall be acceptable to GAF and shall hold current Flor id a Statewide Prod uct Approval, or be Locally
Approved per Rul e 61G20 -3 , per FBC Sections 1507 .2.3, 1507.2 .4 or R905.2.3 .
6.1.3 Fasteners shall be in acco rdance w ith manufacturer's published requiremen t s, but not less than FBC 1507.2.6 or
R905.2 .5 . Staples are not perm itted .
6.1.4 GAF asphalt shingles are acceptabl e for use in reroof (tear-off) or recover app lic ations, subj ect to the limitations set
forth in FBC Section 1511 or R908 and Certain Teed published installation i nstructions.
I 6.2 STARTER SH IN GLES OR STARTER STRIP:
6 .2.1 Installation of Pro -Start Eave/Rake Starter Strip Shingles, WeatherBlocker Prem ium Eave/Rake Starter Strip Shingles
and QuickStart Pee l & Stick Starter Ro ll shall compl y with the GAF current publi shed instructions.
NEMO ETC, I.LC
Certificate of AuthorizoUon #32455 Gm EDITION (2017) FBC NON-HVHZ EVALUATION
GAF Asphalt Roof Shingles
Eva luatio n Report 01506.01.08-RB
FL10124-R21
Revision 23: 0 2/18/2019
Page 4 of 6
8NEMOjetc.
j 6.3 AsPHALT SHINGLES!
6.3.1 Insta ll ation of asphalt shing les shall comply with the GAF current pub li shed instructions, using minimum four (4) nails
per shingle in accordance with FBC 1507.2.7 or R905 .2.6, with the following excep tions :
► Came lot, Cam elot II, Grand Canyo n, Grand Sequoia, Grand Sequoia IR, Grand Sequoia ArmorShi eld, and
Wood land require minimum five (5) nails per shing le.
► Slateline requires minimum six (6) nails pe r shingl e.
6.3.2 Fasteners shall be in accordance with manufacturer's publish ed requirements, but not less than FBC 1507.2.6 or
R905.2.5. Staples are not pe rm itted .
6.3 .3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are req ui red.
Contac t the GAF for details. I 6.4 HtP & RIDGE SHINGLES:
6.4.1 Installation of Seal-A -Ridge Ridg e Cap Shingles
and Seal-A-R idge ArmorShield Ridge Cap
Sh i ngles sha ll comp ly with the GAF current
published instructio ns with a minimum two (2)
nails, minimum 3/8-inch hea d diameter, per
sh ing le and nominal 0.25-in ch diameter beads of
He nkel "Loctite PL S30 Roof & Flashing Sealant".
6.4.2 In st allation of Timbertex Premium Ridge Cap
Sh ingles sha ll comply with GAF cur rent published
instructions with a minimum two (2) nails,
minimum 3/8-inch head diameter, per sh in gle
and beads of Sonneborn "NPl Gun Grade
Po lyurethane Sealant" or Henkel "PL Roofing and
Flashing Sealant".
11.s·
!25 mm) {~~ En du1t d'elanche11e ,..-i _________ , 1· (292mm) r ~:~::
-1 ~ ! I,~• .. ,
Nail
Clnvo
C!ouer 6 5/8. • 7 518"
(168 -194 mm)
1"
(25mm)
12·
(305 mm)
11 s·
(292mm)
(25 mm\ Enduit d'etancMilti
1 Sealont
1"v SelJante ,.....,__ ________ __
9'
(229mm)
I.
!
Nail
Clavo
Clouer
12·
(305mm)
J
12'
(305mm)
6.4.3 Fasteners shall be in accordance with GAF published requirements, but not less than FBC 1507.2 .6 or R905 .2.5.
Sta pl es are not p ermi tted.
NEMO ETC, LLC
Certifica te of Avthorizotion #32455 6"' EDIT ION (2017) FBC NON-HVHZ EVALUATION
GAF Asphalt Roof Shingles
Eva lu a tion Report 0 1506.01.08-R 23
Fl10124-R21
Revision 23 : 02/18/2019