Loading...
328 2nd St RES20-0339 3rd Floor, Repair Stucco and Plywood Permit PacketOWNER:ADDRESS:CITY:STATE:ZIP: LAGARDE KAREN BROWN ET AL 328 2nd STREET ATLANTIC BEACH FL 32233 COMPANY:ADDRESS:CITY:STATE:ZIP: RONALD P ARDARY CONSTRUCTION 1360 SORRELLS CT JACKSONVILLE FL 32221 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 169761 0070 ATLANTIC BEACH JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 328 2ND ST RESIDENTIAL SIDING REPAIR STUCCO AND PLYWOOD - 3rd FLOOR $20000.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $155.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $77.50 STATE DBPR SURCHARGE 455-0000-208-0700 0 $3.49 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.33 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 12/18/2020 PERMIT NUMBER RES20-0339 ISSUED: 12/18/2020 EXPIRES: 6/16/2021 RESIDENTIAL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 TOTAL: $238.32 2 of 2Issued Date: 12/18/2020 PERMIT NUMBER RES20-0339 ISSUED: 12/18/2020 EXPIRES: 6/16/2021 RESIDENTIAL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 DESCRIPTION ACCOUNT QTY PAID PermitTRAK $238.32 RES20-0339 Address: 328 2ND ST APN: 169761 0070 $238.32 BUILDING $155.00 BUILDING PERMIT 455-0000-322-1000 0 $155.00 BUILDING PLAN REVIEW $77.50 BUILDING PLAN CHECK 455-0000-322-1001 0 $77.50 STATE SURCHARGES $5.82 STATE DBPR SURCHARGE 455-0000-208-0700 0 $3.49 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.33 TOTAL FEES PAID BY RECEIPT: R14410 $238.32 Printed: Friday, December 18, 2020 1:17 PM Date Paid: Friday, December 18, 2020 Paid By: RONALD P ARDARY CONSTRUCTION Pay Method: CREDIT CARD 405362606 1 of 1 Cashier: CG Cash Register Receipt City of Atlantic Beach Receipt Number R14410 1 IMPORTANT PERMIT AND INSPECTION NOTES BUILDING. 1. The City Sea Turtle Protection Ordinance applies where land either has frontage on Beach Avenue, the Cloister Condominium, or is located eastward of Seminole Road from 20th Street northward to the City Limits. 2. No fill dirt can be delivered without prior approval from Public Works. Per COAB, 24-68. 3. The bottom of all foundation footings must be minimum 12 inches below existing grade, per COAB, 24-68 and FBC-B, Section 403.1.4. Site conditions may require footings to be deeper or higher above finished grade. Please review COAB Bulletin 1-16 to ensure minimum Finished Floor Elevation (FFE). 4. Fill dirt inside foundation walls must be compacted in 8-inch lifts, per FBC-R506.2.1. Please submit compaction tests, from a third-party testing agency, for every 16 inches of fill or fraction thereof. 5. At Final Inspection, a 6-inch clearance between exterior wall coverings and final grade (top of sod or mulch) will be required, per FBC-R318.7. Please plan FFE and lot grading accordingly. 6. Where questionable soils are found, during inspection, soil and compaction tests may be required, per FBC- R401. 7. Please provide a form-board or stem wall elevation form, from a licensed surveyor, for slab inspection. 8. Please review COAB Bulletin 2-18 to determine if a survey with setbacks and dimensions to property lines is required for slab inspection. 9. The placement and protection of steel reinforcement (Rebar) must comply with FBC-R606 (Masonry) and R608 (Concrete), including required Standard Hooks at top and bottom of vertical rebar. 10. Inspections: a. In-Progress Inspections are required for Exterior Siding and Window and Door Inspections and should be scheduled for the first day of work. b. A Scratch-Coat Inspection is required for stucco work. If you intend to apply a double-up, brown- coat, please call the Building Department to schedule a same-day Scratch-Coat Inspection. c. All roofing projects require an In-Progress Inspection, Residential and Commercial. d. The roof must be complete and the building dried in before scheduling rough trades inspections. 11. The joint tape for ZIP Board products is considered the dry-in or House Wrap for the building and must be inspected before covering over. All holes and penetrations in the sheathing and overdriven nails must be sealed. 12. Please post the building permit documents in a conspicuous location, before start of construction, including the Building Permit, Notice Of Commencement (NOC), and Construction Site Management Plan. The Police Department may review the management plan for compliance and parking. 13. Blocking any sidewalk or street is prohibited without prior approval from the Police Department and City Manager. 2 14. All work must match the approved plans. All changes to the approved plans must be re-submitted for plan review and approved before it can be inspected. Building inspectors are not authorized to approve changes to the approved plans in the field. (See Mechanical) 15. Where excavation is required for new construction, the provisions of FBC-B, Section 3307 will apply, including a 10-Day prior notice to adjoining property owners and protection of adjoining properties. Where the excavation exceeds 24 inches, temporary retaining walls must designed by the Engineer Of Record (EOR) and installed during or immediately after excavation. EXISTING BUILDINGS – REMODELS, RENOVATIONS, ADDITIONS, CHANGE OF OCCUPANCY. 1. Existing buildings are reviewed and permitted under the Florida Building Code-Existing Buildings (FBC- EB). The applicant must specify the method of compliance, per FBC-EB 301.1, and include that information on the plans, with the Design Criteria and Code Analysis. 2. The requirements for the method specified will be found in the corresponding FBC-EB Chapter. 3. When it is discovered during construction that the Compliance Method is not correct, or the project has expanded into another Compliance Method, revised plans will be required to update the Permit. No inspections will be conducted until the approved revisions are on site. 4. Any wall opened by removing interior or exterior wall coverings is considered a Work Area, and current provisions for Energy Conservation, including weatherproofing and insulation will apply. 5. Building inspectors are not authorized to approve changes to the approved plans in the field. ROOFING. a. The roof sheathing for all new construction must remain uncovered until the Roof Sheathing Inspection is approved. b. All roofing projects require an In-Progress Inspection. c. Sheathing installation and replacement guidelines per APA. d. Underlayment must conform to FBC-R Table 905.1.1 e. Shingles must conform to ASTM D3161 G or H, or ASTM D7158 F ELECTRICAL. 1. Electrical work must comply with the provisions of the 2014 NEC. 2. Anti-Oxidant Compound is required on all exterior aluminum wiring connections, unless the Listing Approval Documents for the conductors and the termination points, at each end, specifically allow connection without the compound. (Three documents will be required) PLUMBING. 1. Water supply and drain pipes must be insulated outside of conditioned areas, per FBC-R, P2603.5. 2. Where the entire sanitary drainage system is replaced, the existing building drain and building sewer 3 must be internally examined to verify proper size and slope and that piping is not broken or obstructed, per FBC-R, P2502.1. 3. COAB requires an additional sewer cleanout near the sewer tap with a T-1 concrete box for protection. 4. Water service piping must be properly supported and covered by a minimum of 12 inches of soil, per FBC-R, P2604.3. MECHANICAL. 1. All equipment and duct work must match the approved plans and Energy Sheets. The Manual S is the approved duct plan, and the as-built duct work must match the approved plans, or a revised Manual S or equivalent must be submitted for review. An equivalent must include duct and trunk layout and sizes, available static pressure, actual air flow, and total effective length, signed by the Mechanical Contractor with State License Number. FUEL GAS. 1. Fuel gas systems from the regulator to the appliances must comply with the FBC-Gas. 2. LP gas storage systems and outside piping must comply with NFPA 58. 3. All underground gas piping and tubing must be buried with 12-inches of cover. 4. CSST gas piping must comply with the manufacturer’s installation instructions and terms of approval. 4 01/23/20, 02/13/20 Building Permit Application Updated 10/9/18 City of Atlantic Beach Building Department ALL INFORMATION 800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY Phone: (904) 247-5826 Email: Building-Dept@coab.us IS REQUIRED. Job Address: "2 U 2...4aS! }9T/L,n,7i 1.36.-ch 33 Permit Number: I\O 1 33 Legal Description J4-pi .0 C $Ta,.Cco 0,i iP/yr we( y,,' A iZ 7- 3 kg.RE# Valuation of Work (Replacement Cost)$2U 08 c/ Heated/Cooled SF Non-Heated/Cooled Class of Work: ElNew EAddition Alteration ARepair Move Demo Pool Window/Door Use of existing/proposed structure(s): Commercial *Residential If an existing structure, is a fire sprinkler system installed?: Yes DNo Will tree(s) be removed in association with proposed project? EYes(must submit separate Tree Removal Permit) VNo Describe/' in detail the type of work to be performed: //c iC 5cv.J .-/ Ccrf`''y ScT e o/e(./•, 'fig, /ire.+/c r,xXdilzuXs c„wf f'iy,.b:o4 3f'TC'if%f iiiJj) , ielti la 1'e ccrol g /.2.)<f FtscT Florida Product Approval# .yC'.e- F'f rii'/% rex.. ;•-e' e.e t,' - C for multiple products use product approval form Property Owner Information! ' did Name YY',i,, (Z. 2:+ Address 32`' Z ~ 5 1ce1 T/6:0%4 A-6,44 f :72.2.73 City OTIA.44-,i 6re,. , State fi-i, Zip 3,Z J3 Phone 9'OV ' ,c32.— `I V '3 E-Mail C+Rdc't2 C tn,,i/• cot-, Owner or Agent(It Age i{, Power of Attorney or Agency Letter Required) Contractor Information n n / Name of Company (v>> !d / 4/2v sy C vST Qualifying Agent tec,tifsy/ P b..,v'•,r Address J)6o 5,eIe//y CT , / City <TGLc-kse,v i /c State ft Zip 3ZZZ/ Office Phone WV 7* - (UO3. Job Site Conta9t- - Number 7e1 $(7 `c 4, State Certification/Registration# CUC '(iSb bG; E-Mail a,Cu1 -yL G( J.-we-T./; r/ tyC Architect Name& Phone# J Engineer's Name& Phone# Workers Compensation Insurer £ i-r,`Ji 61.'.if f'vvycii_y1;.c'C OR Exempt%_Expiration Date %1/?Zl_/ Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RE y'R TICE OF COMMENCEMENT. 4_,410 T Signature of Owner or Agent) Signature of Contractor) igned and sworn to(or affi m:d1b- •re ' e this day of Sign d and sworn to(or a• it ed)befor- me this 7day of L)c ZU- - 4 4 4 L G L= ir><, .Zo C.) . Z•,,w-c ' E As•AN Si azure • •• :- igna u e of •ota. V.P.4y` TONI GINDLESFr_RGER o,* PYPu,,, I G'•NDLESI"' ?GER N. " i_ MY COMMISSION#GG 333178 1.:' ,rn °% MY COMMISSIONGG 353178 I Personally Known OR uf. 7mW EXPIRES:October 6,2023 [ Personally Known OR u :* r l.:a: EXPIRES:. .,.ber 6,2023 Produced Identification FpFF qQ` Produced Identification 7::f?)." 61:•''': EcndedThruNot.1 f__uh!icUnderTtersBondedThruNotaryPublicUnenvrite9. • Type of Identification: Type of Identification: LJ