Loading...
1735 Maritime Oak ROW21-0001 Permit PacketOWNER:ADDRESS:CITY:STATE:ZIP: COMPANY:ADDRESS:CITY:STATE:ZIP: SOUTHEAST UTILITIES 1 ENERGY PL PENSACOLA FL 32520 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 169505-1785 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 1735 MARITIME OAK DRIVE RIGHT OF WAY SINGLE OR TWO FAMILY RIGHT OF WAY ROW - CABLE BORE for COMCAST $0.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL Notes: All runoff must remain on-site during construction. 2 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL Notes: Roll off container company must be on City approved list. Approved list can be obtained at the Building Department at City Hall. Roll off container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 1/7/2021 PERMIT NUMBER ROW21-0001 ISSUED: 1/7/2021 EXPIRES: 4/7/2021 RIGHT OF WAY PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT TOTAL: 3 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration, including sod, is required. 4 PUBLIC WORKS RUNOFF INFORMATIONAL Notes: All runoff must remain on-site. Cannot raise lot elevation. 5 PUBLIC WORKS INFRASTRUCTURE INFORMATIONAL Notes: Any damage done to infrastructure must be repaired by Contractor. 6 PUBLIC WORKS AS-BUILT INFORMATIONAL Notes: Contractor must submit As-Built plans to City within 30 days after completion of project. 7 PUBLIC UTILITIES UNDERGROUND WATER SEWER UTILITIES INFORMATIONAL Notes: Avoid damage to underground water and sewer utilities. Verify vertical and horizontal location of utilities. Hand dig if necessary. If field coordination is needed, call 247-5878. 2 of 2Issued Date: 1/7/2021 PERMIT NUMBER ROW21-0001 ISSUED: 1/7/2021 EXPIRES: 4/7/2021 RIGHT OF WAY PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 ½;W-\.i'J:r 1$ !r} Q • ,j> ~ 11\ ;:;' ,.!\ -;> _, ,. S-) u .....,..-2: ~J.Q;il\:J~ I I I I I I I I I I I I I I I H:\Applications & Forms\Word Documents\201801001 Right-of-Way Easement Permit Application.docx Revision Date: 10/1/18 **ALL INFORMATION HIGHLIGHTED IN GRAY IS REQUIRED. RIGHT-OF-WAY / EASEMENT PERMIT APPLICATION City of Atlantic Beach 800 Seminole Road, Atlantic Beach, FL 32233 PERMITTEE RESPONSIBLE FOR NOTIFYING 811 AND OBTAINING UTILITY LOCATES Job Address_________________________________________________ Permit Number________________________ Contractor Information Company______________________________________________ Qualifying Agent_____________________________ Address______________________________________ City________________________ State______ Zip___________ Phone________________________________________ Email_______________________________________________ State Certification/Registration #_______________________________________________________________________ Architect_____________________________________ Phone____________________ Email______________________ Engineer_____________________________________ Phone____________________ Email_______________________ Workers Compensation Insurer ____________________________________ OR Exempt □ Expiration Date __________ Permittee declares that prior to filing this application they have ascertained the location of all existing utilities, both aerial and underground and the accurate locations are shown on the sketches. Whenever necessary for the construction, repair, improvement, maintenance, safe and efficient operation, alteration or relocation of all, or any portion of said street or easement as determined by the Public Works Director, any or all said poles, wires, pipes, cables or other facilities and appurtenances authorized hereunder, shall be immediately removed from said street or easement or reset or relocated hereon as required by the Public Works Director and at the expense of the Permittee unless reimbursement is authorized. All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed under the supervision of ____________________________________________________________________ (Project Superintendent) with (Company Name) ________________________________________________Phone_____________________________ All materials and equipment shall be subject to inspection by the Public Works Director. All city property shall be restored to its original condition as far as practical, in keeping with City specifications and th e manner satisfactory to the City. A sketch of plans covering details of this installation, as well as a copy of a recent survey shall be made a part of this permit. Calculations showing any increase in impervious area on owner’s lot or in the City right -of-way are to be included with this application. The permittee shall commence actual construction in good faith within _______ days. If the beginning date is more than 60 days from date of permit approval then permittee must review the permit with the Public Works Director to make sure no changes have occurred in the area that would affect the permitted construction. It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City’s right, title and interest in the land to be entered upon and used by the holder, and the holder will, at all times, assume all risk of and indemnify, defend and save harmless the City of Atlantic Beach from and against any and all loss, damage and cost of expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges. The Public Works Director shall be notified 24 hours prior to starting work and again immediately upon completion. _______________________________________________________________________________ Date________________________ Permittee (signed in presence of Notary Public) STATE OF FLORIDA, COUNTY OF DUVAL The foregoing instrument was acknowledged this ___________ day of ________________________________________, 20 _________, by _______________________________________________________________________, who personally appeared before me and (printed name of Permittee) acknowledged that he/she signed the instrument voluntarily for the purpose expressed in it. __________________________________________________________ [ ] Personally Known Signature of Notary Public, State of Florida [ ] Produced Identification (Type) _______________________ 1-4-2021 I - - - - ROW21-0001 OKALOOSA CO UNTY I DUVAL COUNTY I VICINITY MAP: 1735 MARITIME OAK DR, ATLANTIC BEACH, FL 32233 POLK COU TY MANATEE HAROEE CO UNTY CO UNTY DESO TO CO UNTY CHARLOTTE COUNTY LEE COUN TY HENDRY COU NT Y PALM BEAC H C OUNTY BRO WAR D COUN TY MIAMI-DADE COUN T Y COMCAST PERMIT REQUEST FOR 1735 MARITIME OAK DR, ATLANTIC BEACH, FL 32233 THESE PLANS WERE PREPARED UNDER THE RESPONSIBLE CHARGE OF COMCAST AND ARE EXEMPT FROM THE SIGNING AND SEALING REQUIREMENTS PRESCRIBED IN SECTION 471 OF THE FLORIDA STATUTES NO EXPECTED CONFLICTS WITH OTHER UTILITIES LOCATION: 1735 MARITIME OAK DR, ATLANTIC BEACH, FL 32233 TOTAL LENGTH OF JOB: 150' .fk COMCAST DESCRIPTION: PROPOSED CABLE BORE PLACEMENT DRAWN BY: JM DATE: 12/31/20 HEET 1 OF 5 SCALE: NTS NOTES: ALL PROPOSED UNDERGROUND CATV WILL BE BURIED A MINIMUM OF 36" DEEP EXCEPT ROAD BORES 60" DEEP AND DRIVEWAY BORES AT 60" DEEP. ALL PROPOSED UNDERGROUND CATV ROAD BORES WILL USE CITY APPROVED DIRECTIONAL BORE MACHINE, AS WELL AS COUNTY APPROVED CONDUIT. ALL PROPOSED CATV ROAD BORES WILL EXTEND A MINIMUM OF 7' BEYOND THE EDGE OF PAVEMENT. ALL PROPOSED CATV DRIVEWAY BORES WILL EXTEND A MINIMUM OF 6' BEYOND THE EDGE OF PAVEMENT. ALL PROPOSED BORES WILL BE IN A (4'X4'X4') PIT AND WILL USE (2)2" HOPE CONDUIT AT 48" DEPTH USING A 5 1 / 4" DRILL HEAD. ALL PROPOSED AERIAL WILL BE .700" DIAMETER AND WILL BE LASHED TO .250" STEEL STRAND CABLE USING .125" STANDARD GALVANIZED LASHING WIRE. ALL PROPOSED AERIAL CATV CROSSING ROADWAYS WILL HAVE MINIMUM MID-SPAN HEIGHT OF 18'-0" ALL PROPOSED AERIAL CATV CROSSING DRIVEWAYS WILL HAVE MINIMUM MID-SPAN HEIGHT OF 16'-0" LOCATES WILL BE REQUIRED IN ALL PROPOSED UNDERGROUND AREAS AT LEAST 48 HRS PRIOR TO CONSTRUCTION. NOTIFICATIONS TO ALL UTILITIES INVOLVED WILL BE MADE PRIOR TO CONSTRUCTION. ALL DISTRIBUTED AREA WITHIN THE RIGHT OF WAY WILL BE RESTORED TO ORIGINAL OR BETTER CONDITION BY GRADING AND RE-SODDING. SOD ALL AREAS DISTURBED BY CONSTRUCTION WITH BERMUDA SOD. "ALL CRACKED SIDEWALK IS TO BE REPLACED FROM JOINT TO JOINT WITHIN 7 DAYS OF WORK COMPLETION." WORK OPERATIONS ARE TO BE MINDFUL NOT TO DAMAGE THE PAVER SIDEWALK WHEN POSITIONING EQUIPMENT. ANY DAMAGE INCLUDING TRACK MARKS WILL BE REPAIRED OR REPLACED BY THE CONTRACTOR. CONSTRUCTION NOTES: IN ORDER TO REDUCE THE DISRUPTION AND COST OF UTILITY DAMAGES OCCURRING IN THE RIGHT-OF-WAY AND EASEMENTS. THE PERMITTEE SHALL PREVENT DAMAGES TO EXISTING UTILITIES CAUSED BY THE WORK THROUGH FIELD VERIFICATION OF THE LOCATION OF THE EXISTING UTILITIES IN CASE OF OPEN EXCAVATION. VERIFICATION MAY BE PERFORMED DURING THE PERMITTEES WORK. IN THE CASE OF DIRECTIONAL DRILLING, VERIFICATION SHALL TAKE PLACE PRIOR TO MOBILIZATION OF THE DRILLING EQUIPMENT. THE PERMITTEE SHALL VERIFY THE LOCATION OF THE EXISTING UTILITIES AS NEEDED TO AVOID CONTACT WITH DETECTION EQUIPMENT OR OTHER ACCEPTABLE MEANS, SUCH METHODS MAY INCLUDE BUT SHALL NOT BE LIMITED TO-"SOFT DIG"-EQUIPMENT AND GROUND PENETRATION RADAR (GPR). THE EXCAVATOR SHALL BE HELD LIABLE FOR DAMAGES CAUSED TO CITY'S/COUNTIES/STATE INFRASTRURE AND THE EXISTING FACILITIES OF THE OTHER UTILITY COMPANIES NO REAMER USED THE FOLLOWING STANDARD PLANS ARE IN ACCORDANCE WITH THE FLORIDA DEPARTMENT OF TRANSPORTATION 2020-2021 102-602, 102-660 INDEX AND APPLY TO: 1735 MARITIME OAK DR, ATLANTIC BEACH, FL 32233 COMCAST PERMIT REQUEST FOR 1735 MARITIME OAK DR, ATLANTIC BEACH, FL 32233 INO BACKREAMER USEDI I NO EXPECTED CONFUCTSI WITH OTHER UTILITIES LOCATION: 1735 MARITIME OAK DR, ATLANTIC BEACH, FL 32233 TOTAL LENGTH OF JOB: 150' .fk COMCAST DESCRIPTION: PROPOSED CABLE BORE PLACEMENT DRAWN BY: JM DATE: 12/31/20 SHEET 2 OF 5 SCALE: NTS 117471 117411 PROPOSED CABLE BORE PLACEMENT FOR 150' ALONG MARITIME OAK DR AT MIN DEPTH OF 36" USING 2" 13.5 SOR ROLL PIPE WITH COAXIAL CABLE INSIDE 117351 117291 TEL PED ELEC PAD CATV PED BEGIN BORE HERE 1+50 ~ a:::: 13' 3' 5' SW 36"MIN. 48"MIN. MARITIME OAK DR 50' c., -20' cld1CL 5' oo w GRASS N I C1/L I l I I I c., z <Id <( (/) 0 LOOKING WEST ~ a:::: c., 13' a.. .:a oo w R C\I 0' lo 00 36"MIN. 13' I 48"MIN. 11' 9' I 7' '~ ~ ffi j::'.:...J "a:::: cldo ...J r<Cw Ot,-w <Col-- (/) ;: INO BACK REAMER USEDI NO EXPECTED CONFLICTS WITH OTHER UTILITIES LOCATION: 1735 MARITIME OAK DR, ATLANTIC BEACH, FL 32233 TOTAL LENGTH OF JOB: 150' .fk COMCAST DESCRIPTION: PROPOSED CABLE BORE PLACEMENT DRAWN BY: JM DATE: 12/31/20 HEET 3 OF 5 SCALE: NTS END ROAD WORK c[] <:= A <:= c[] ROAD WORK AHEAD -----------------------------------------+------------------------------ ==:> I ==:> Di Di Di I ■ A B * I ■ ■ • • • • 1//:/~:::::::~/0W, ---:i-1 Taper Le ngth= ½L ½/ /I /J/ ---------------Se_e_T-ab-le_I_I -~--i /1//////// /// /~ ---~ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Di ROAD I WORK • AHEAD t,; Device Spacing-Taper Device Spacing-Tangent See Table I See Table I 500' END RO AD WO RK SPEEDING FINES DOUBLED WHEN WORKERS PRESENT Table I Device Spacinq fv1ax. Distan ce Between Devices (ft.) Speed Cones or Type I or Type II Barricades or Vertical DISTANCE BETWEEN SIGNS (mph) Tubular Markers Panels or Drums Speed 4 0 mph or less 45 mph 50 mph or greater *Midway between signs. SYMBOLS LJ Work Area ■ Channelizing De v ice (See I ndex 102 -600) Di Work Zone Sign Lane I dentification + Direct i on of Traffic < DESCRIPTION: 0 Spacing (ft.) T aper Tangent Taper A B 25 25 50 25 200 3 50 500 200 30 to 45 25 50 30 350 500 50 to 70 25 50 50 GENERAL NOTES 1. When four or more work vehicles enter the through traffic lanes in a one hour period or less (excluding establishing and terminating the work area), the advanced FLAGGER sign shall be substituted for the WO RKERS sign . For location of flaggers and FLAGGER signs, see Index 102-603. 2. SHOULDER WORK sign may be used as an alternate to the WORK ER symbol sign only on the side where the shoulder work is being performe d . 3. When a s i de road intersects the highway within the TT C z one, additional TT C devices shall be p laced in accordance with othe r ap p licable TCZ Indexes . 4. For general TCZ requirements and additional information, refer to I ndex 102-600. Tangent 50 50 100 DURATION NOTES 1. Signs and channelizing de vices may be omitted if all of the following conditions are met: a. Work operations are 60 minutes or less. b . Vehicles in the work a r ea have high-intensity, rotating, flashing, oscillating, or strobe lights operating. Table II Taper Length -Shoulder ½L (ft) Speed (mph) 8' 10' Notes 12 ' Shldr. Shldr. Shldr. 25 28 3 5 42 30 40 50 60 L= ws 2 35 55 68 82 60 40 72 90 107 45 120 150 180 50 133 167 200 55 147 183 220 60 160 200 240 L=W5 65 173 217 260 70 187 233 280 8 ' minimum shoulder width ½L = Length of shoulder taper in feet W = Width of total shoulder in feet (combined paved and unpaved width) S = Posted speed limit (mph) CONDITIONS WHERE ANY VEHICLE, EQUIPMENT, WORKERS OR THEIR ACTIVITIES ENCROACH THE AREA CLOSER THAN 15' BUT NOT CLOSER THAN 2 ' TO THE EDGE OF TRAVEL WAY. INDE X LAST REVISION 11/01/17 vi ;: FY 2020-21 STANDARD PLANS TWO-LANE , TWO-WAY, WORK ON SHOULDER 102-602 Lu ci:: SHEET 4 □ F 5 ¢= - c:::::=:> <;:= c:::::=:> LAST REVISION 11/01/17 SYMBOLS ~ Work Area ■ [Ji Channelizing Device Work Zone Sign fCR\--Required Locations For Either Temporary '-.:::.:.1/ \ Or Permanent Curb Ramps. c:::::=:> Lane Identification + Direction of Traffic •=• Pedestrian Longitudinal Channelizing Device /LCD) with Mounted Work Zone Sign or separate Work Zone Sign ...,.. Pedestrian Longitudinal Channelizing Device (LCD) m Temporary Sidewalk ------ CI~ (/) 0 m m 0 ~ -I r I ;,s m 0 ;:o r U> 0 0 (/) m m 0 ~I~ I I ~-- c;:::;:i ---- 3H3H SSOKl O\/3H\/ O3SO78 >ll\/M30IS 03SO78 >ll\f M301S ~ _JQ <(W s(/) wO 0 _J -U C/) filu (/) w 0 a:: .....,o w (_)<( :r: ::.:'.W CJ) .....1:r: (/) <C<( 0 s: a:: w 0 u5 BI SIDEWALK CLO SED • • USE OTHER SIDE hL3U ( < DES CR IPTION: 0 vi ;: Lu ci:: CJ CROSSWALK CLOSURE ANO PEDESTRIAN DETOUR GENERAL NOTES : 1. When encroaching work requires a sidewalk closure for 60 minutes or greater, provide an alternate pedestrian route . 2. For spacing of vehicular Channelizing Devices, see applicable vehicular temporary traffic control I ndexes. 3. Cover or deactivate pedestrian traffic signal display/s) controlling closed crosswalks. 4 . Fo r post mounted signs located near or adjacent to a sidewalk, maintain a minimum 7' clearance from the bottom of the sign panel to the surf ace of the sidewalk. 5. Provide a 5' wide temporary walkway, except where space restrictions warrant a minimum width of 4'. Provide a 5' x 5' passing space for temporary walkways less than 5' in width at intervals not to exceed 200'. ¢= c:::::=:> ~ c{] CJ rrV c0 6. Provide a cross-slope with a maximum value of 0 .02 for all temporary walkways . 7 . Maintain temporary walkway surfaces and ramps that are stable, firm, slip-resistant, and free of any obstructions or hazards such as holes, debris, mud, construction equipment, and stored material. 8. Remove temporary walkways immediately after reopening of the sidewalk, unless otherwise noted in the plans. 9. Meet the requirements of Index 522-002 for temporary curb ramps. JO . Place pedestrian longitudinal channelizing device/s) across the full width of the closed sidewalk. For temporary walkways, similar to the Sidewalk Di versi on, place LCDs to delineate both sides of the temporary walkway. J J. For sidewalk diversions, ensure that there is sufficient R/W for plac e ment of temporary sidewalk and pedestrian longitudinal channelizing devices. F 03SO78 >ll\f M301S SIDEWALK CLOSED F A\/M>ll\/M '- N\/IH1S303d 1il PEDESTRI AN ;f WALKWAY / SIDEWALK DETOUR SIDEWALK DIVERSION FY 2020-21 STANDARD PLANS PEDE§TRJCAN CONTROL FOR CLOSURE OF S JCDE WALKS INDE X 102-660 SHEET 5 □ F 5