1240 Seminole Rd RES19-0102 Blower DoorEnvelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
Jurisdiction: Permit #: f, E ��� _ 0 1 0---z—
Job Information
Builder: \ J. Community: '�'j 1,4 Lot: *11r,
Address: Z( (�P `N lfoi (C-)
City: State: L Zip:
Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method
PRESCRIPTIVE METHOD -The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 a,
changes per hour at a pressure of 0.2 inch w.g. (50 Pascals) in Climate Zones 1 and 2.
PQ PERFORMANCE or ERI METHOD -The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceec
the selected ACH(50) value, as shown on Form R405-2017 (Performance) or R406-2017 (ERI), section labeled as infiltration, sub -section ACI
ACH(50) spec ified on Form R405 -2017 -Energy Calc (Performance) or R406-2017 (ERI): 0.000
x 60 + 42996' _ 9(3
CFM(50) Building Volume ACH(50)
IN2 PASS
® Wheh ACH(50) is less than 3, Mechanical Ventilation installation
must be verified by building department.
Method for calculating building volume -
0 Retrieved from architectural plans
• Code software calculated
O Field measured and calculated
8402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pasc
Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Sec
489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration
control measures.
2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control
measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
i e5ung gompany
Company Name:
1 hereby verify thate a ve Air leakage results are in accordance with the 201 Phone:
Energy Conservation requirements a 6th Edition Florida Building Code
g to the compliance method selected above.
Signature of Tester:
Date of Test: ' ��
Printed Name of Tester: Thomas Keller
License/Certification #: RFI# ]EGS2x
Issuing Authority: RESNET
12/13/2019 12:26:34 PM EnergyGauge® 11S
?,3 (--Z� p 6x•04 (Rev. 1) - FlaRe92017 F8C 6th Edition (2017) Compliant SoRwa�o , ..E
Scanned with Cam c neer
Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
Jurisdiction: —1 Permit #: (�� � i Ql - O 1 O—Z—_
b Information
Iilder: 1 �.I Community: Ir4__j1 Lot:
Aress: I -.)- k ` 0 -C'r-e r" ,, ('- (I j C A r'r %C.tz- t -t Q'.)SIG-7
ity: State: Zip:
►ir Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method
��PRESCRIPTIVE METHOD -The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 ai
changes per hour at a pressure of 0.2 inch w.g. (50 Pascals) in Climate Zones 1 and 2.
Q PERFORMANCE or ERI METHOD -The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceec
the selected ACH(50) value, as shown on Form R405-2017 (Performance) or R406-2017 (ERI), section labeled as infiltration, sub -section AGF
ACH(50) specified on Form 8405 -2017 -Energy Calc (Performance) orR406-2017 (ERI): 1 0.000
CFM(50)
Building Volume
1Z PASS
ACH(50)
Method for calculatinq building volume:
O Retrieved from architectural plans
40 Code software calculated
When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated
must be verified by building department.
.c r esung. i esting shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pasc
Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Sec
489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infritratior
control measures.
2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control
measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be fumed off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
Testing Company
Company Name: _
I hereby verify that th
Energy Conservation
Signature of Tester:
41�10ve Air Leakage sults are in accor ance with the Phone:
Edition Florida Building Code
equirements Ing to the complian ==selected
moo selected above.
Date of Test: 2 �Z
Printed Name of Tester: omas Keller
License/Certification #: RFI# JEG52X
Issuing Authority: RESNET
Scanned wilh CamScanner