Loading...
1182 E Linkside Ct RESO20-0041 Roof Mounted Solar Permit PacketOWNER:ADDRESS:CITY:STATE:ZIP: SHERMAN ANGELA M 1182 LINKSIDE CT E ATLANTIC BEACH FL 32233-4386 COMPANY:ADDRESS:CITY:STATE:ZIP: SOLAR TREK, INC.3347 SW 7th STREET OCALA FL 34474 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 172374 5135 SELVA LINKSIDE UNIT 01 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 1182 E LINKSIDE CT RESIDENTIAL OTHER SINGLE OR TWO FAMILY RESIDENTIAL OTHER ROOF MOUNTED SOLAR POOL HEATER $4550.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $75.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $37.50 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $116.50 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 12/17/2020 PERMIT NUMBER RESO20-0041 ISSUED: 12/17/2020 EXPIRES: 6/15/2021 RESIDENTIAL OTHER PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 2 of 2Issued Date: 12/17/2020 PERMIT NUMBER RESO20-0041 ISSUED: 12/17/2020 EXPIRES: 6/15/2021 RESIDENTIAL OTHER PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 DESCRIPTION ACCOUNT QTY PAID PermitTRAK $116.50 RESO20-0041 Address: 1182 E LINKSIDE CT APN: 172374 5135 $116.50 BUILDING $75.00 BUILDING PERMIT 455-0000-322-1000 0 $75.00 BUILDING PLAN REVIEW $37.50 BUILDING PLAN CHECK 455-0000-322-1001 0 $37.50 STATE SURCHARGES $4.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL FEES PAID BY RECEIPT: R14387 $116.50 Printed: Thursday, December 17, 2020 2:57 PM Date Paid: Thursday, December 17, 2020 Paid By: SOLAR TREK, INC. Pay Method: CREDIT CARD 405066778 1 of 1 Cashier: CG Cash Register Receipt City of Atlantic Beach Receipt Number R14387 RESO20-0041 TYPICAL MULTIPLE COLLECTOR ARRAY PLAN SCALE: 1 4"=1'-0" 2 SR-4.0 4'-0" TYP. SUNSTAR COLLECTOR TYP. SUNSTAR CLAMP (2 MINIMUM) TYP.END CAP TYP. SUNSTAR CLAMP (2 MINIMUM) TYP. TYP SUNSTAR CLAMP. REFER TO SCHEDULE FOR BOLT SIZE PER DETAIL THIS SHEET TYPICAL COLLECTOR PITCHED ROOF LAYOUT - WIND ZONES - SCHEDULE - PLAN SCALE: NONE ULTIMATE WIND SPEED Vult (MPH) Vasd WIND PRESSURES ZONE 1 (PSF) QUANTITY OF LAG BOLTS - TOP AND BOTTOM CLAMPS PER COLLECTOR - EFFECTIVE DESIGN WIND AREA IS 12.5 SF PER COLLECTOR FOR STR-50. -SCHEDULE REFLECTS COMPONENTS AND CLADDING (C&C) NOMINAL WIND SPEED PRESSURES WITH EXPOSURE "C", RISK CATEGORY II, ENCLOSED BUILDING AND h < 60'-0" PER ASCE 7-10 "MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES" AND 2017 FLORIDA RESIDENTIAL CODE. - PLUS AND MINUS SIGNS SIGNIFY PRESSURES ACTING TOWARD AND AWAY FROM SURFACES, RESPECTIVELY. EMBED. DEPTH REQ. Vasd WIND PRESSURES ZONE 2 (PSF) Vasd WIND PRESSURES ZONE 3 (PSF) - MINIMUM Vasd WIND PRESSURE SHALL BE 16.0 PSF AND -16.0 PSF PER ASCE 7-10 SECTION 30.2.2. 1 SR-4.0 SUNSTAR COLLECTOR GENERAL NOTES: 2. BOLT DIAMETER AND EMBEDMENT LENGTHS ARE DESIGNED PER 2017 FLORIDA BUILDING CODE (6TH EDITION) REQUIREMENTS . ALL BOLT CAPACITIES ARE BASED ON A SOUTHERN YELLOW PINE (SYP) RESIDENTIAL WOOD ROOF TRUSS AS EMBEDMENT MATERIAL. 3. ALL WIND DESIGN CRITERIA AND PARAMETERS ARE FOR HIP AND GABLE RESIDENTIAL ROOFS, CONSIDERING FROM A 7° TO A MAXIMUM 27 ° (2/12 TO A MAXIMUM 6/12 PITCH) ROOF IN SCHEDULE. ALL RESIDENTIAL ROOFS SHALL NOT TO EXCEED 30'-0" MEAN ROOF HEIGHT. 4. WIND TUNNEL TEST DATA FOR THIS COLLECTOR MAY BE REQUESTED THROUGH UMA SOLAR, INC. AND HAS BEEN COMPILED BY PRI CONSTRUCTION AND MATERIAL TESTING, INC. 5. ROOF SEALANTS SHALL CONFORM TO ASTM C920 AND ASTM 6511, AND IS THE RESPONSIBILITY OF THE CONTRACTOR TO PILOT FILL ALL HOLES. 6. THIS SHEET REFLECTS STRUCTURAL CONNECTIONS ONLY. REFER TO SUNSTAR INSTALLATION MANUAL FOR ALL ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, AND SOLAR SPECS. 7. LAG BOLTS SHALL BE ASTM A276 STAINLESS STEEL UNLESS OTHERWISE NOTED. 8. ALL SUNSTAR COLLECTOR MODELS MAY BE INSTALLED PER THIS STRUCTURAL CONNECTION DRAWING. 1. APPLICABLE CODE: 2017 FLORIDA RESIDENTIAL CODE (6TH EDITION) & ASCE-7-10 MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES. 2 1 2 2 2 2 1 3 3 2 3 3 3 3 2 2 1 2 2 GABLE END BUILDING ROOF WIND AREA ZONES HIP END BUILDING ROOF WIND AREA ZONES1 1 2 2 SR-4.0 2 SR-4.0 ** LAG BOLT DEPTH REQUIRED IN WOOD MEMBER SHALL EXCLUDE ANY ROOF DECKING THICKNESS. 140 16.5 , -27.9 16.5 , -48.6 16.5 , -71.8 3" **(4) 1 4" DIA. BOLTS - (4) CLAMPS 4' - 0 " T Y P . 4'-0" TYP. 9. CONTRACTOR SHALL ENSURE ALL ROOF PENETRATIONS TO BE INSTALLED AND SEALED PER 2017 FLORIDA RESIDENTIAL CODE (6TH EDITION) OR LOCAL GOVERNING CODE. 10. THE ADDITION OF THE SUNSTAR COLLECTOR SYSTEM ADDS APPROXIMATELY 1 PSF TO THE ROOF STRUCTURE AND WILL NOT ADVERSELY AFFECT THE STRUCTURAL INTEGRITY OF THE BUILDING. OPTIONAL ALL THREAD CONNECTION DETAIL SCALE: 1"=1'-0" 5 SR-4.0 LIMITED SPACE OPTION FOR UNALIGNED TRUSS 1 4" DIA STEEL ALL-THRD ROD W/ NUT - WASHERS MAX. 3'-0" O.C.-LOCTITE ALL NUTS TYP. ALL CONNECTIONS 2X PT S.Y.P. WOOD OR ALUMINUM UNISTRUT CONT. ALONG COLLECTOR SUNSTAR TOP CLAMP 2'-0" O.C. TYP. WOOD ROOF TRUSS TYP. WOOD SHEATHING TYP. SUNSTAR COLLECTOR RISER SYSTEM TYP. SUNSTAR BOTTOM CLAMP 2'-0" O.C. TYP. 1 4" DIA STEEL ALL-THRD ROD W/ NUT - WASHERS MAX. 3'-0" O.C.-LOCTITE ALL NUTS TYP. ALL CONNECTIONS ROOF ASPHALT OR METAL SHINGLES TYP. SUNSTAR TOP CLAMP 2'-0" O.C. TYP. WOOD ROOF TRUSS TYP. WOOD SHEATHING TYP. ROOF ASPHALT OR METAL SHINGLES TYP. SUNSTAR COLLECTOR RISER SYSTEM TYP. SUNSTAR BOTTOM CLAMP 2'-0" O.C. TYP. 1 4" DIA. STEEL LAG BOLT - SEE SCHEDULE FOR EMBED. DEPTH REQ. TYP. EACH BOTTOM CLAMP TYP TOP - BOTTOM ASPHALT - METAL SHINGLE CONNECTION DETAIL SCALE: 1"=1'-0" 3 SR-4.0 REFER TO SCHEDULE FOR REQUIRED EMBEDMENT DEPTH LABELED "X" IN THIS DETAIL 1 4" DIA. STEEL LAG BOLT - SEE SCHEDULE FOR EMBED. DEPTH REQ. TYP. EACH TOP MOUNT CLAMP X OPTIONAL WOOD SPANNER OPTION CONNECTION DETAIL SCALE: 1"=1'-0" 4 SR-4.0 S.Y.P. 2X4 LOCATE BETWEEN TRUSSES AND NAIL WITH 2-16D NAIL PATTERN AT EACH END TO WOOD TRUSS X REFER TO SCHEDULE FOR REQUIRED EMBEDMENT DEPTH LABELED "X" IN THIS DETAIL SUNSTAR TOP CLAMP 2'-0" O.C. TYP. WOOD ROOF TRUSS TYP. WOOD SHEATHING TYP. ROOF ASPHALT OR METAL SHINGLES TYP. SUNSTAR COLLECTOR RISER SYSTEM TYP. SUNSTAR BOTTOM CLAMP 2'-0" O.C. TYP. 1 4" DIA. STEEL LAG BOLT - SEE SCHEDULE FOR EMBED. DEPTH REQ. TYP. EACH BOTTOM CLAMP 1 4" DIA. STEEL LAG BOLT - SEE SCHEDULE FOR EMBED. DEPTH REQ. TYP. EACH TOP CLAMP EN G I N E E R O F R E C O R D H E R E B Y E X P R E S S L Y R E S E R V E S H I S C O P Y R I G H T A N D O T H E R P R O P E R T Y R I G H T S I N T H E S E P L A N S . T H E S E P L A N S A N D D R A W I N G S A R E N O T T O B E RE P R O D U C E D , C H A N G E D O R C O P I E D I N A N Y F O R M O R M A N N E R W H A T S O E V E R W I T H O U T F I R S T O B T A I N I N G T H E E X P R E S S P E R M I S S I O N A N D C O N S E N T O F T H E D E S I G N E R , N O R A R E TH E Y T O B E A S S I G N E D T O A N Y P A R T Y W I T H O U T F I R S T O B T A I N I N G S A I D W R I T T E N P E R M I S S I O N A N D C O N S E N T . DO N O T S C A L E D R A W I N G S : C O N T R A C T O R S S H A L L V E R I F Y A N D B E R E S P O N S I B L E F O R A L L D I M E N S I O N S A N D C O N D I T I O N S O N T H E J O B A N D T H I S OF F I C E M U S T B E N O T I F I E D O F A N Y V A R I A T I O N F R O M T H E D I M E N S I O N S A N D C O N D I T I O N S S H O W N B Y T H E S E D R A W I N G S .