51 BEACH AVE RES19-0058_REV 6-3-20 _S1.6__1"A
0
4 ARCH BACKGROUND CHANGED
UPPER LEVEL ROOF FRAMING PLAN
SCALE: 3/6"=1'-0"
SYMBOLS AND HATCH DESIGNATION LEGEND
(2)H2.5T
WOOD UPLIFT CONNECTOR
HTS16
WOOD HIGH UPLIFT CONNECTOR
HTSM16
CMU HIGH UPLIFT CONNECTOR
PORCH CEILING SHEATHING, TABLE 8/SO.0
ROOF FRAMING NOTES:
1. SEE TABLE 6/SO.0 FOR ROOF SHEATHING SPECIFICATIONS
2. EA TRUSS OR RAFTER MUST HAVE MIN (2)12d TOENAILS
AND (1)SIMPSON H2.5T FASTENED TO DOUBLE TOP
PLATE. SEE FOR 2/S2.1(CMU) OR 5/S2.2(WOOD) FOR
CONNECTION DETAIL (UON ON PLAN)
3. WHEN USING (2)TWIST STRAPS ON Q2" WIDE LUMBER,
PLACE STRAPS DIAGONALLY ACROSS DOUBLE TOP PLATE
FROM EA OTHER, TO AVOID SPLITTING WOOD.
4. IMPORTANT NOTE: SUPPORT JACK TRUSSES AT ALL,
CORNERS W/ 2x10xl2'-0" LONG PT STRUCTURAL FASCIA,
FASTENED TO EACH TRUSS W/ A34.
I•17L
Lou Pontigo and
Associates, Inc.
4745 Sutton Park Court, #204
Jacksonville, Florida 32224
Ph. 904-242-0908
FL CA # 8344
www.LP-A.com
Luis A UneRI araC Ind d-1, c W s A
lnreo.
Pontigo O00016o0 1ot—as0 oa Qosm
Luis A. Pontigo, PE
FL PE#53311
FIELD ALTERATION
CONTRACTOR SHALL CONTACT LOU
PONT GO &ASSOCIATES PRIOR TO
MAKING ANY STRUCTURAL FIELD
MODIFICATIONS WHICH MAY VARY
FROM THE INTENT OF THE ORIGINAL
CONSTRUCTION DOCUMENTS. ANY
FIELD ALTERNATIONS MADE PRIOR TO
BEING APPROVED BY LOU PONTIGO &
ASSOCIATES MAY RESULT IN
ADDITIONAL ENGINEERING OR
INSPECTION FEES.
w j
ZLLJ LL
w z 2
D
LU U
Lij Q m
zL)
DU �
Lf) w
Z
Z
m �
OLn Q
cn
UPPER LEVEL
FRAMING
PLAN
DO NOT SCALE DIMENSIONS FROM
THESE DRAWINGS. IF A DIMENSION IS
UNCLEAR REFER TO THE
ARCHITECTURAL DRAWINGS OR
CONTACT THE E.O.R.
LPA DWG TEMPLATE
RESIDENCE
DRAWN/DESIGN/CHECKED
WAC WAC / LAP
DATE
08.01.19
SCALE
AS NOTED
LPA JOB #
RSOR-19-0039
SQUARE FOOTAGE
SHEET
S1,61
SHEET 14 OF 20