Loading...
110 S Saratoga Cir ROOF21-0002 Permit PacketOWNER:ADDRESS:CITY:STATE:ZIP: LI MING AND HANJING SHU FAMILY TRUST ST AUGUSTINE FL 32080 COMPANY:ADDRESS:CITY:STATE:ZIP: Best Roof Jax LLC 10752 DEERWOOD PARK BLVD JACKSONVILLE FL 32256 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 171799 0000 ATLANTIC BEACH VILLA # 02 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 110 S SARATOGA CIR ROOF NON SHINGLE MODIFIED BITUMEN $6000.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $85.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $42.50 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $131.50 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 1/20/2021 PERMIT NUMBER ROOF21-0002 ISSUED: 1/20/2021 EXPIRES: 7/19/2021 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 2 of 2Issued Date: 1/20/2021 PERMIT NUMBER ROOF21-0002 ISSUED: 1/20/2021 EXPIRES: 7/19/2021 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 DESCRIPTION ACCOUNT QTY PAID PermitTRAK $131.50 ROOF21-0002 Address: 110 S SARATOGA CIR APN: 171799 0000 $131.50 BUILDING $85.00 BUILDING PERMIT 455-0000-322-1000 0 $85.00 BUILDING PLAN REVIEW $42.50 BUILDING PLAN CHECK 455-0000-322-1001 0 $42.50 STATE SURCHARGES $4.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL FEES PAID BY RECEIPT: R14645 $131.50 Printed: Wednesday, January 20, 2021 2:02 PM Date Paid: Wednesday, January 20, 2021 Paid By: Best Roof Jax LLC Pay Method: CREDIT CARD 415456512 1 of 1 Cashier: CG Cash Register Receipt City of Atlantic Beach Receipt Number R14645 1/17/2021 Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqvweIwRFXRvHOHSbalV%2f8EtEwKml7TNAMmEePdWFs1K%2bg%3d%3d 1/2 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL2533-R24 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer CertainTeed, LLC (Roofing) Address/Phone/Email 20 Moores Road Malvern, PA 19355 (610) 893-5400 mark.d.harner@saint-gobain.com Authorized Signature Mark Harner mark.d.harner@saint-gobain.com Technical Representative Mark D. Harner Address/Phone/Email 18 Moores Road Malvern, PA 19355 (610) 651-5847 Mark.D.Harner@saint-gobain.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Modified Bitumen Roof System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Robert Nieminen Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 09/15/2023 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL2533_R24_COI_2020_01_COI_NIEMINEN.pdf Referenced Standard and Year (of Standard)Standard Year ASTM D1970 2015 ASTM D2178 2015 ASTM D4601 2012 ASTM D4897 2009 ASTM D6163 2015 ASTM D6164 2011 ASTM D6222 2011 ASTM D6509 2015 ASTM G155 2013 FM 4470 2016 ROOF21-0002 1/17/2021 Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqvweIwRFXRvHOHSbalV%2f8EtEwKml7TNAMmEePdWFs1K%2bg%3d%3d 2/2 FM 4474 2011 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 07/30/2020 Date Validated 08/04/2020 Date Pending FBC Approval 08/08/2020 Date Approved 10/13/2020 Summary of Products FL #Model, Number or Name Description 2533.1 Flintlastic Modified Bitumen Roof Systems Modified Bitumen Roof Systems Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-635 Other: 1.) Refer to ER Section 5 for Limits of Use. 2.) The design pressure noted in this application relates to one specific system. Refer to the ER Appendix for all systems and max design pressures. Installation Instructions FL2533_R24_II_2020_07_20_FINAL_A1_ER_CERTAINTEED_MODBIT_FL2533- R24.pdf Verified By: Robert Nieminen, PE PE-59166 Created by Independent Third Party: Yes Evaluation Reports FL2533_R24_AE_2020_07_20_FINAL_ER_CERTAINTEED_MODBIT_FL2533- R24.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 25: 07/20/2020 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 1 of 74 APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE TABLE DECK APPLICATION TYPE DESCRIPTION PAGE 1A Wood New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 5 1B Wood New or Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 6-8 1C Wood New, Reroof (Tear-Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 8 1D Wood New, Reroof (Tear-Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 9-10 1E Wood New, Reroof (Tear-Off) or Recover D Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 11-13 1F-1 Wood New, Reroof (Tear-Off) E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 13-16 1F-2 Wood New, Reroof (Tear-Off) or Recover E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 16-18 1G Wood New or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 18 2A Steel or Structural concrete New, Reroof (Tear-Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 19-21 2B Steel or Structural concrete New, Reroof (Tear-Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 22-26 2C Steel or Structural concrete New, Reroof (Tear-Off) or Recover D Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 27-29 3A Structural concrete New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 30-39 3B Structural concrete New or Reroof (Tear-Off) A-3 Bonded Temp Roof/Vapor Barrier, Bonded Insulation, Bonded Roof Cover 40 3C Structural concrete New or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 40 4A LWIC / steel New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 41-42 4B LWIC / structural concrete New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 43-46 4C LWIC / structural concrete New, Reroof (Tear-Off) A-1 Bonded Vapor Barrier, Bonded Insulation, Bonded Roof Cover 47-48 4D LWIC / steel New or Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 49-51 4E LWIC / steel or struct. conc. New or Reroof (Tear-Off) E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 52-57 4F LWIC / steel Reroof (Tear-Off) or Recover E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 57 4G LWIC / steel Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 58 5A Cementitious wood fiber New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 59 5B Cementitious wood fiber New or Reroof (Tear-Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 60 5C Cementitious wood fiber Reroof (Tear-Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 61 5D Cementitious wood fiber New, Reroof (Tear-Off) or Recover E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 61 6A Existing gypsum Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 62-64 6B Existing gypsum Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 64-65 6C Existing gypsum Reroof (Tear-Off) C Mech. Attached Insulation, Bonded Roof Cover 65 6D Existing gypsum Reroof (Tear-Off) E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 66 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 67-74 7B Various Recover F Non-Insulated, Bonded Roof Cover 74 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 25: 07/20/2020 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 18 of 74 TABLE 1F-2: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Base Fasteners Attach Base Ply Cap Ply W-100 Min. 19/32-inch plywood; 24-inch span Glasbase; Flexiglas; Flintlastic Base 20; Poly SMS Base; Ultra Poly SMS Base; Yosemite Venting Base Note 2 7-inch o.c. at 3-inch lap and 7- inch o.c. in three (3), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -105.0 W-101 Min. 19/32-inch plywood; 24-inch span Flintlastic APP Base T OMG 3 in. Round Metal Plates with OMG #14 HD or Dekfast Hex Plate with Dekfast #14 7-inch o.c. at 3-inch lap and 7- inch o.c. in three (3), equally spaced, staggered center rows None APP-TA APP-TA -105.0 W-102 Min. 15/32-inch plywood; 24-inch span Glasbase; Flexiglas; Flintlastic Base 20; Poly SMS Base; Ultra Poly SMS Base; Yosemite Venting Base FlintFast 3 in. Insulation Plates with FlintFast #12 or #14; Trufast 3” Metal Insulation Plates with DP or HD; OMG 3 in. Round Metal Plates with OMG #14 HD 6-inch o.c. at 4-inch lap and 6- inch o.c. in four (4), equally spaced, staggered center rows None (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -127.5 W-103 Min. 15/32-inch plywood; 24-inch span Flintlastic APP Base T OMG 3 in. Round Metal Plates with OMG #14 HD 6-inch o.c. at 4-inch lap and 6- inch o.c. in four (4), equally spaced, staggered center rows. None APP-TA APP-TA -127.5 COLD-APPLIED SYSTEMS: W-104 Min. 15/32-inch plywood; 24-inch span Glasbase; Flexiglas Base; Flintlastic Base 20; All Weather / Empire Base; Yosemite Venting Base; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base FlintFast 3 in. Insulation Plates with FlintFast #12 or #14; Trufast 3” Metal Insulation Plates with DP or HD 8-inch o.c. at 4-inch lap and 8- inch o.c. in three (3), equally spaced, staggered center rows None (Optional) SBS-CA1 SBS-CA1 -52.5 TABLE 1G: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER System No. Deck (Note 1) Primer Roof Cover (Note 15) MDP (psf) Base Ply Ply Cap Ply W-105 APA rated, min. 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing; 24-inch span FlintPrime or FlintPrime SA Flintlastic SA Mid Ply, self-adhering (Optional) SBS-SA SBS-SA -90.0 W-106 Min. 15/32-inch plywood; 24-inch span FlintPrime or FlintPrime SA SBS-SA-H (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -112.5 W-107 Min. 15/32-inch plywood; 24-inch span FlintPrime or FlintPrime SA SBS-SA (Optional) SBS-SA SBS-SA -127.5 ROOF21-0002