Loading...
1201 Gladiola Street SMARTVENT127 W. Fairbanks Ave.  Suite 438  Winter Park, FL 32789  407.644.6957 PH  407.644.2366 FX  contact@buildingdrops.com      Alexis Spyrou, P.E.    Florida No. 68101   BUILDING DROPS A Perfect Solution in Every Drop  Certificate of Authorization: 29578  Product Evaluation Report of Smart Vent Products, Inc. “FloodVent Model #1540-520” “SmartVent Model #1540-510” “Wood Wall Flood Model #1540-570” “Wood Wall Flood Overhead Door Model #1540-574” “FloodVent Overhead Door Model #1540-524” “SmartVent Overhead Door Model #1540-514” for Florida Product Approval FL# FL5822-R2 Report No. 1550 Florida Building Code 2007 & 2010 Per Rule 9N-3 Method: 2 – B (Engineering Evaluation) Category: Structural Components Sub – Category: Products Introduced as a Result of New Technology Other Sub-Category: Ventilation Product: Automatic Foundation Flood Vents (AFFV) Material: Stainless Steel Product Dimensions: Foundation Dimensions-15 3/4” x 7 ¾” Wood Wall Dimensions- 14” x 8 ¾” Prepared For: Smart Vent Products, Inc. 430 Andbro Drive, Unit 1 Pitman, NJ 08071 Prepared by: Alexis Spyrou, P.E. Florida Professional Engineer # 68101 Date: 11/28/2011 Contents: Evaluation Report Pages 1 – 3   ALEX SPYROU 2011.12.14 21:11:53 -05'00' FL#: FL5822-R2 Date: 11/28/2011 Report No: 1550     Alexis Spyrou, P.E.    Florida No. 68101  Page 2 of 3    BUILDING DROPS A Perfect Solution in Every Drop  Certificate of Authorization: 29578  Manufacturer:    Smart Vent Products, Inc.    Product Category:  Structural Components    Product Sub‐Category:  Other    Other Sub‐Category:  Ventilation    Compliance Method:  State Product Approval Rule   9N‐3.005 (2)(b)    Product Name:    FloodVent Model #1540‐520      SmartVent Model #1540‐510      Wood Wall Flood Model #1540‐570      Wood Wall Flood Overhead Door Model #1540‐574      FloodVent Overhead Door Model #1540‐524      SmartVent Overhead Door Model #1540‐514  Foundation Dimensions‐15 3/4” x 7 ¾”       Wood Wall Dimensions‐ 14” x 8 ¾”  Scope:   This is a Product Evaluation Report issued by Alexis Spyrou, P.E. (FL # 68101) for Smart Vent  Products, Inc. based on Rule Chapter No. 9N‐3.005, Method 2b of the State of Florida Product  Approval, Department of Community Affairs ‐ Florida Building Commission.    Alexis Spyrou, P.E. does not have nor will acquire financial interest in the company manufacturing or  distributing the product or in any other entity involved in the approval process of the product named  herein.    This product has been evaluated for use in locations adhering to the 2007 & 2010 Florida Building  Code.    See Installation Instructions provided by Smart Vent Products, Inc., verified by Alexis Spyrou, P.E. (FL  # 68101) for specific use parameters.    Limits of Use:   1.   This product has been evaluated and is in compliance with the 2007 & 2010 Florida Building  Code, including the “High Velocity Hurricane Zone” (HVHZ).  2. Product anchors shall be as listed and spaced as shown on details.  Anchor embedment into  substrate material shall be beyond wall dressing or stucco.  3. When used in areas requiring wind borne debris protection this product complies with  Section 1609.1.2 of the Florida Building Code and does not require an impact resistant  covering.        FL#: FL5822-R2 Date: 11/28/2011 Report No: 1550     Alexis Spyrou, P.E.    Florida No. 68101  Page 3 of 3    BUILDING DROPS A Perfect Solution in Every Drop  Certificate of Authorization: 29578  Limits of Use (cont.):  4. Site conditions that deviate from the details of the drawings require further engineering  analysis by a licensed engineer or registered architect.    5. See Installation Instructions for size and design pressure limitations.  6.  Wall construction shall meet requirements of Section 1612 and Appendix G of the FBC as  deemed technically relevant due to site conditions.    Quality Assurance: The manufacturer has demonstrated compliance of ventilation products in  Accordance with the Florida Building Code and Rule 9N‐3 for manufacturing under a  quality assurance program audited by an approved quality assurance entity through  Architectural Testing, Inc. (FBC Organization #: QUA 1844)     Performance Standards: The product described herein has been tested per:   ASTM E 330‐02   ASCE 24‐05   TAS 202‐94  Code Compliance:  The product described herein complies with 2010 FBC Section 1714.2 and the intent      of 2010 FBC Section 1612.5(1)(1.2).  Referenced Data:  1. Product Testing performed by Architectural Testing, Inc.       (FBC Organization # TST1558)        Report #: 01‐42966.01, Report Date: 11/15/02       Report #: 38957.102‐122‐44, Report Date: 11/16/05       Report #: 60619.01‐122‐47, Report Date: 11/16/05       Report #: 61877.01‐122‐44, Report Date: 01/06/06       Report#: 94135.01‐109‐18, Report Date: 08/31/09        2.  Quality Assurance    Architectural Testing, Inc.  (FBC Organization #: QUA 1844)         3.  ICC Evaluation Service       ESR‐2074: Meets requirements of AC364       Reissued February 1, 2011        Installation: Refer to Installation Instructions by Manufacturer for installation requirements.    Design Pressure:   Design Pressures  +100/‐100 PSF