Loading...
1201 Gladiola Street SMARTVENT InstallWood Monday, June 02, 2003 14:34:03 SIDEBYSIDEBLOCK.dwg 8-23-05EXTERIOR VIEWSIDE SECTION VIEWFINAL GRADE DOORREMOVEDDOOROPENFRAMEEXTERIORUPPER STRAPSBEHIND WALLBOTTOM STRAPSBEHIND WALLALTERNATESIDE STRAPSBEHIND WALLINTERIORDOOR SHOWN OPENIN FRAMEOPENOPENOPENOPENALTERNATE STRAPS LOCATIONS ON SIDES 2 PLS.DETAIL "C"DRILL AND INSTALL 2 SS SHEETMETAL SCREWSOVERLAP ONE VENT FLANGE OVER THE OTHER,SILICONE JOINTROUGH OPENING 33"STRAPS GO BEHIND WALL AND CAN BE BROKEN OFF AT SLOTS TO AVOID OBSTRUCTIONSROUGH OPENING 8 1/4"Smart VENT® BLOCK OR POURED SIDE BY SIDE INSTALLATION INSTRUCTIONS877-441 8368WWW.SMARTVENT.COMSmart VENT® LINTEL IS REQUIREDPER LOCAL BUILDING CODE12" MAX going behind wall above opening. Push frame into opening so front flange is tight to face of wall.6. Caulk or adhesive may be applied behind front frame flange. Tilt frame so top goes into wall opening first with strap legs ONLY PUSH STRAPS ONE CLICK INTO FRONT SLOTS. Straps should have bent legs pointing up.4. Insert four straps into two top sets of slots in frame from rear. After pushing teeth through rear set slots, 3. Remove door from frame. (turn upside down, rotate bottom of door outward and slide out of slots)2. Measure wall thickness and bend (more than 90°) 8 straps at nearest slot to the measurement from pointed end.1. Prepare a CLEAN 33 " wide by 8-1/4" high rough opening for each vent (2 block wide x 1 block high) 10. Let the bottom of the door go so that the door rotates down into the frame. Check that door is latched on both sides. following the path of the slots, until they are at the bottom of the slots in the dimples. Slide door into frame such that metal pins on each side slide into slots on sides of frame. Let the door slide down 9. Install door into frame by grasping bottom of door (with plastic pins down) and the word "TOP" facing up. 8. Check that frame is square and slots are clear of debris, mortar and caulk. between front flange and bent strap. Squeeze all straps tight. Frame should be flush to wall face and secure. 7. Reach through frame opening and install two bent straps through two bottom sets of slots in frame, trapping wall with the bottom of the hole no more then 12" above finished grade. 11. Insert two thin blades or cards into the float slots and unlatch the door to insure free functionality, then latch again.5. With the two outside vent frames sandwiched together drill and screw the two frames together with 2 SS sheet metal screws. SIDEBYSIDEBLOCKwsleeve.dwg 8-23-05EXTERIOR VIEWSIDE SECTION VIEWFINAL GRADE DOORREMOVEDDOOROPENFRAMEEXTERIORINTERIORDOOR SHOWN OPENIN FRAMEOPENOPENOPENOPENDETAIL "C"DRILL AND INSTALL 2 SS SHEETMETAL SCREWSOVERLAP ONE VENT FLANGE OVER THE OTHER,SILICONE JOINTROUGH OPENING 33"ROUGH OPENING 8 1/4"Smart VENT® BLOCK OR POURED SIDE BY SIDE WITH INSIDE SLEEVE INSTALLATION INSTRUCTIONS877-441 8368WWW.SMARTVENT.COMSmart VENT® LINTEL IS REQUIREDPER LOCAL BUILDING CODE12" MAX4. With the two outside vent frames sandwiched together drill and screw the two frames together with 2 SS sheet metal screws2. Remove door from frame. (turn upside down, rotate bottom of door outward and slide out of slots)1. Prepare a CLEAN 33 " wide by 8-1/4" high rough opening for each vent (2 block wide x 1 block high) 9. Let the bottom of the door go so that the door rotates down into the frame. Check that door is latched on both sides. following the path of the slots, until they are at the bottom of the slots in the dimples. Slide door into frame such that metal pins on each side slide into slots on sides of frame. Let the door slide down 8. Install door into frame by grasping bottom of door (with plastic pins down) and the word "TOP" facing up.3. Dry fit the frames in place making sure there are no obstructions and that the front flange sits against the flat outside wall. with the bottom of the hole no more then 12" above finished grade. 10. Insert two thin blades or cards into the float slots and unlatch the door to insure free functionality, then latch again.INTERNAL FINISH SLEEVE SHOWNINSTALLEDCALK AS REQUIRED Insert the inner sleeve from the inside of the building through the opening and over the vent frame.5. Apply construction adhesive around the front frame flange where shown. Do not apply adhesive to the inside of vent! and press in place.6. Apply construction adhesive around the inside trim flange where shown. Do not apply adhesive to the inside of vent! and press in place.7. Calk as requiredADHESIVE HERE ALL AROUNDzp