Loading...
1565 E Park Ter ACC20-0086 Permit PacketOWNER:ADDRESS:CITY:STATE:ZIP: RADLER WILLIAM 1565 E PARK TER ATLANTIC BEACH FL 32233 COMPANY:ADDRESS:CITY:STATE:ZIP: TUFF SHED INC 1116 Blanding Boulevard Orange Park FL 32065 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 171958 0000 SELVA MARINA UNIT 02 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 1565 E PARK TER ACCESSORY SINGLE OR TWO FAMILY ACCESSORY 10' x 15' DETACHED STRUCTURE $11098.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL Notes: All runoff must remain on-site during construction. 2 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL Notes: Roll off container company must be on City approved list. Approved list can be obtained at the Building Department at City Hall. Roll off container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 12/21/2020 PERMIT NUMBER ACC20-0086 ISSUED: 12/21/2020 EXPIRES: 6/19/2021 ACCESSORY PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $110.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $55.00 PW REVIEW BUILDING MOD OR ROW 001-0000-329-1004 0 $25.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.48 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 ZONING REVIEW SINGLE AND TWO FAMILY USES 001-0000-329-1003 0 $100.00 TOTAL: $294.48 3 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration, including sod, is required. 4 PUBLIC WORKS DECKING REMOVED INFORMATIONAL Notes: All old decking and debris must be removed from job site by Contractor. 5 PUBLIC WORKS INFRASTRUCTURE INFORMATIONAL Notes: Any damage done to infrastructure must be repaired by Contractor. 2 of 2Issued Date: 12/21/2020 PERMIT NUMBER ACC20-0086 ISSUED: 12/21/2020 EXPIRES: 6/19/2021 ACCESSORY PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 DESCRIPTION ACCOUNT QTY PAID PermitTRAK $294.48 ACC20-0086 Address: 1565 E PARK TER APN: 171958 0000 $294.48 BUILDING $110.00 BUILDING PERMIT 455-0000-322-1000 0 $110.00 BUILDING PLAN REVIEW $55.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $55.00 PUBLIC WORKS PLAN REVIEW $25.00 PW REVIEW BUILDING MOD OR ROW 001-0000-329-1004 0 $25.00 STATE SURCHARGES $4.48 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.48 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 ZONING PLAN REVIEW $100.00 ZONING REVIEW SINGLE AND TWO FAMILY USES 001-0000-329-1003 0 $100.00 TOTAL FEES PAID BY RECEIPT: R14423 $294.48 Printed: Monday, December 21, 2020 11:40 AM Date Paid: Monday, December 21, 2020 Paid By: TUFF SHED INC Pay Method: CREDIT CARD 406056179 1 of 1 Cashier: CG Cash Register Receipt City of Atlantic Beach Receipt Number R14423 ~+; CENTRALSQUARE ACC20-0086 0 ·-,-.. z:a(')"' o=>(')CI) _a....,_.: . ...J >,O ~N :::,:ONwN -c., 0 :I: O(!) CN 2 z o. ~ :.it: ·u; a;,_ z~ c .~~ <( <5 .S! Eu <(U::~E:U >--·;:: o::i: z o c:U <("'E> r-§8~ U) 'fl' 3i :!= %\ ~~I --,,,,o~ .... ~ .... , ... 11l/11l\\' Building Permit Application City of Atlantic Beach 800 Seminole Road, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Fax: (904) 247-5845 Updated 12/8/17 Job Address: I 5 \a5 E G.-'5 :r e°=', )<.. Legal Description d.7 -~ to·, . -RE# \ 1 \ 9 5 3 -ODOO Lo-\-8 \K. Valuation of Work (Replacement Cost) \ _.....;;;.. __ Non-Heated/Cooled._1..;.lo...;;O __ _ • Class of Work (Circle one):~ Addition Alteration Repair Move Demo Pool Window/Door • Use of existing/proposed structur (s) {Circle one): Commercial {Fesldentia]) • If an existing structure, is a fire sp 'inkier system installed? (Circle one): Yes No @ • Submit a Tree Removal Permit Ap llcation if any trees are to be removed or Affidavit of No Tree Removal Describe In detail the type of work to be prormed: / o' X I lo I De.tac.he.ct Stru.. c..--1-u..re_ Florida Product Approval #:...{).,_...u..~,--4~=-..!..!.l.l!::~~..i,_-----for multiple products use product approval form Property · Name: t....) 1 Address: \ Sl¢?5 f:a..-,,+ Pa....-\l... Te..rca.c~ City A+\ 1 E-Mail rh. State~ Zip 3 ;i;;(:33 Phone 2 I J -159-~ S,;n Owner or rnl!y or AgencyletterRequlred) _Q.....,W=-<o...:.e.c=-. _____________ _ Contractor Information l Name of Company: T u.;tt. Shea ·, fI-nc, . Qualifying Agent: -, 0 M Sa. ...... " e+{ Address )777 5. \-\arn son S;\..i ·-:ti:= laOO City Qs:.n,&e State Co tip ])'0;11 D Office Phone 3c)3 -7.53 -8033 · l Job Site/Contact Number _9:..;0::..S...:..,,i,,,-,.uK-l\k,.,,Q~-... J..w..;l l:..;O..___ ______ _ State Certification/Registration# (..eiC. lg s ?iley s: E-Mail +hi I \ i Qo@ :i:ld-££;s}wL C.Dm Architect Name & Phone# __.N-;::f-'/ft...,__.....,..-;-!-..,..,..,----,,.---=-~==---,=,.......,=----------------- Englneer's Name & Ph ~· ·.,,.._""""' ....... -+-'-...·...,_,_...,_____.""--'--.!....<"""--""'..u._..l..c'---~--.-----=------- Workers Compensatlo o.." e.. . '3/1/;}~I llation has commenced prior tot ulationg construction in this Ju SIGNS, I ~t~.()fthis ',"R~tv,I!!'A ,ijs,n~es,or OWNER'S AFFIDAVIT: I certify that all the tr,regojng Information is accurate and that all work will be done in compliance with all applicable laws regulating construction anf zoning. WARNING TO OWNER: YOUR ~AILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN TTORNEY BEFORE RECO D11tJ~U"~liMIIII~ 0~ COMMENCEMENT. I/ " {Slgnatur11 of owner or nt) (Including contracto ) st Signed and sworn to (or affirmed) befor~ me this_\_ day of 'Df ee_o-kt.r. J.oao . by , i), \\.; Q&-, ~ a.r\\ e.-c r) Signed and sworn to (or affirmed) before me this .t,_ day of April 2019 . •' ::j,~ ~) 1 1 : EVY ( } Per$onally Known OR M' Personally Known OR Bl..lC {~duced identlflcatlonr-. L [ J Produced Identification RADO Type of Identification: u Type of Identification: --D1Ul.f,:-J,ilf~:..f'fl~::!f:P-E'~!i1::.,~:!F~€~0r.2~3!!6~26~ru l JUNE 6, 2021 --·····-, ·--·•·•··------··-' " --•--·-----·-·"·' -··-·-·· ··-·-.. ·---··--·· ···-........ -. ----·-·-·-·····--.. ·····---····--•··•· Revision Request/Correction to Comments City of Atlantic Beach Building Department 800 Seminole Rd, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Building-Dept@coab.us [II Revision to Issued Permit OR D Corrections to Comments Project Address: 1565 E. Park Terrace **ALL INFORMATION HIGHLIGHTED IN GRAY IS REQUIRED. PERMIT#: ACC20-0086 Date: 12/08/2020 Contractor/Contact Name: Tuff Shed , lnc./Mindy Higgins -------------------------------- Contact Phone: (904) 860-7110 Email: thulion@tuffshed.com ------------- Description of Proposed Revision/ Corrections: Attached signed drawings which include auger anchor details on page 3 I_T_uff_S_h_ed_, _1nc_.1_M_in_dy_H_ig_gi_ns ______ affirm the revision/correction to comments is inclusive of the proposed changes. (printed name) • Will proposed revision/corrections add additional square footage to original submittal? 0No D Yes (additional s.f. to be added: ____________ ) •~ill proposed revision~c_orrec~ions ad~ add'.ti~nal increase in building value to original submittal? li.JNo D*Yes (add1t1onal increase in building value:$ _________ ) (Contractor must sign if increase in valuation) *Signature of Contractor/ Agent: ______________________ _ ✓ (Office Use Only) ~ Approved D Denied D Not Applicable to Department Permit Fee Due $ ------ Revision/Plan Review Comments _____________________________ _ Department Review Required: Building Planning & Zoning Tree Administrator Public Works Public Utilities Public Safety Fire Services Reviewed By Date Updated 10/17/18 Doc# 2020269404, OR BK 19478 Page 2431, Number Pages: 1, Recorded 12/04/2020 01:18 PM, RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL COUNTY RECORDING $10.00 NOTICE OF COMMENCEMENT Permit No. ____ _ Tax Folio No. 11 / 9 58' -OCOO State of Florida, County ofDuval THE UNDERSlGNED hereby give notice that the improvement will be made to certain real property In accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. I. Description of property (legal description of property lllld address if available): JJ-!a l\o-,;5-~9E Sc..lva. IOa:cioa. Qn.;+ot Lo:\:~ e.\\(,4 2. General Description of improvements: IQ' x Ile' Dd·o,c..bed. 5-n:,1..d·u..c:te 3. Owner Infurmation: a)NameandAddress: \.)~\\ia,t,Q «a.d\:ec · 'S!aS b) Interest in property: l c) Name and address of simple titleholder (if other than owner): E Pru:¥-Terca.~J A+\a,r--\:JC .. f-au..h I FL 3.;u1,3 4. Contractor Infonnation: a)NameandAddress:T-.....q:: 5bro ;Inc,• lDO 6\aoAioa A\vd.~1e,· Dro.nJJec fo.rl!-,f'L b) Phone Number. :}o 4 • :8'4>0 ~ :Z II O .J 3 ;.i~ b5 S. Surety Infonnat!on: a)NameandAddress:-":.+.L"-------------------------- b) Phone Number. -c)AmountofBon·d~:-=s:---------------- 6. Lender Information:~ a)NameandAddress: -'-=t.a.:A:,..._ _______________________ _ b)PhoneNwnbcr.. ______________ _ 7. Person within the Stale of Florida designated by owner upon whom notices or other documents may be served as provided by 713.13 (l)(a) 7, Florida Statutes: a) Name 1111d Address: ~\ft:_ b) PhoneNwnbersorDes==:1-1~..._..,d"'P""m_o_n_: ______________________ _ 8. In addition to himself/herself; Owner designates N) A-of _____ to receive a copy of the Lienor's Notice as provided in Section 71U3 (1) (b), Florida Statutes. a)Neme and Address: __________________________ _ b) Phone Number of person or entity ~gnated by owner:-==~---------- 9. Expiration dale ofNotice of Commencement (the expiration date may not be before the completion of construction and final pa~nt to the contractor, but will be one (I) year from the date of recording unless a different date is specified: ~ \ ;la;l-\ WARNING TO OWNER: ANY PAYMENTS MADE BY nIEOWNERAFJBR THE EXPIRATION OF THE No·ncE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION lliJl, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENClNG WORK OR RECORDJNG YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury, 1 declare that I have read the foregoing notice of commencement and that the facts stated ;-;-;: w:;: ""'"'"""" "''"'· lW; \\i o..ro '.]; .. dler Ip..,.....,- sigJ.L6f0wner~'sAuthorized Officer/Director/Partner/Manager Signatory's Printed Name & Title/bffice The foregoing instrument was acknowledged before me by means of ~ical presence orDonline notam.ation, this~dayof \'lecu:rab?f .ZO~bY. \,0;\\;o..m :8,cv;\)er .whoispersonallyknownto (NGmC of Person) me or produced _..:0:.....:L--________ as identification, es=---,,.~--.,,.---.,,.---=----=--__,,,,.---,...,,..-,-,-·j . ~ty,e.g.. officer, attorney Inflict, ell:.) -for __ __,..-------,--..,....,,--'- (Namo of Party lnstnamcnt was ~cuted for) ,,,~~W;,,, TANYA ANN HULION ~~~~ State of Florida-Notary Public =• •~~~Mr"Yl"lGG 201337 ~J'.~ i'l My Commission Expires '11 ~~,'.\1'' March 28 2022 NOTARY PUBLIC SIGNATURE-STATE OF F~pRTDA Commissioned Notary Name: TQ...,n 'i Q ~ I , DQ Revised 1/1/2020 ACC20-0086 TREE & VEGETl.\noN AFFIDAVIT City of Atlantic Brach Community Oeveloprent Department 800 Seminole Road ! Atlantic Beach, FL 32233 (P) 904-247-5800 ! I SITE INFORMATION . FOR INTERNAL OFFICE USE ONLY PERMIT# ____ _ ADDRESS 1565 Ea.st Po.-r-~ \'c.-r-:a.ce ) f\+-lw:hc · (:),a.ch I FL 3~23 susolV!stON '.:};; \ v a. f(\o,,r, oO:--BLOCK 4 LoT _Z __ j ! RE# \7 \ 9 S;J'-OOOD APPLICANT INFORMATION ! I NAME \,0;\\ i Q.., •~ ~ CLci \ -<£,( ADDRESS 15L,5 Ea:s,+: \?a.t:J \exrn.c:e,_ ). ! CITY \\ .\-\a_r,~-~ e, l::ieac.h i I [g"RESIDENTIAL O COMMERCIAL □OTHER PHONE# O )1 -r'jfi-'fS5J 7 I\+ \a. n+lc. 6ea.c.J, CELL# 'ti\ 7 -1'6<, -~ 5;;:i.7 STATE FL ZIP CODE --=3-'~'"'-'~'""3'-3"'------ EMAIL ,.,.Y, a.c\ kc@ :3nra.; l . c..b fY'. B'PWNER □ LEGAL AUTHORIZED AGENT I I affirm that I have reviewed the brovlsions of Chapter 23, "Protection of Trees and Native Vegetation", of the Municipal Code of OrdinancJ for the City of Atlantic Beach Florida. and/or 1. have participated in a pre- applkation meeting with. the A·linlstrator of those reg .. ulatlons. Subsequently, I affirm that no regul~ted trees and no regulated vegetat10 . will be damaged, destroyed and/or removed from the above-descnbed property and/or adjacent prope ,es including right-of-way. l I IIERBIYCEJmfYlllAT AU_,. ' NPROVIDEP'rii\\ll;i~OWner(,)o, 7."iid~ ! PRINTORTVPE NAME DATE SIG ! - SIGNATUREOFAPPUCANT:(2) l PRINTORTYPE·NAME Slgned,andswornbeforeffleonthls l ½!._ dayof ~ec.e.mbe., . ~D;;!Oby 1..0; \\ ) cu-,, ::-1?,ou::I\ "-' r oath Sworn: D Yes 04 fflEEAND VEGETATIONAFFIDAVfr0:1.01.2018 DATE State of 'F I Ort. 60-.. County of D v.. voJ? Tuff Shed, Inc. Permit # 1777 S. Harrison St. #600 Denver, CO 80210 Customer Name State of Florida License #CBC1253645 Customer Address Product Approval Cover Sheet As required by Florida Statute 553.842 and Florida Administrative Code 9B-72, please provide the information and product approval number(s) for the building components listed below if they will be utilized on the building or structure. Florida approved products are listed online at www.floridabuilding.org or can be obtained from the local product supplier. All products listed are per Florida Building Code 6 th Edition (2017) Shed Materials Used Product Type Manufacturer Model # FL Product Expiration Windows TAFCO Corporation Series 82000 FL20743.1 6/17/2026 Windows Silver Line Building Products V1 Series/70 Series FL14911.5 8/3/2021 Siding (Lap) LP Corp Lap FL10477.1 1/1/2021 Siding (Panel) LP Corp LP Smartside FL9190.6 12/31/2030 Roof Underlayment Woodland Industries Inc Felt FL17206.1 6/24/2024 Roof Underlayment GAF Felt FL18686.1 2/22/2023 Shingles GAF GAF FL10124.1 12/16/2022 Fixed Transom Innovations Manufacturing Transom FL17667.1 12/31/2020 Flood Vents Flood Solutions LLC Foundation FL17588.1 3/31/2022 Doors Tuff Shed Inc Premiere - Double Door FL22202.1 6/14/2028 Doors Tuff Shed Inc Premiere - Single Door FL22202.2 6/14/2028 Doors Tuff Shed Inc Sundance - Double Door FL22202.3 6/14/2028 Doors Tuff Shed Inc Sundance - Single Door FL22202.4 6/14/2028 Steel Door - Inswing JELD-WEN 6-panel/3068/Inswing FL22513.6 6/30/2021 Steel Door - Outswing JELD-WEN 6-panel/3068/Outswing FL22513.6 6/30/2021 Full Lite Door JELD-WEN 3068 FL17454.1 12/31/2027 Full Lite Door JELD-WEN 6068 FL17454.1 12/31/2027 9 Lite Door JELD-WEN 3068 FL17454.1 12/31/2027 ACC20-0086 1565 W PARK TER I I I II I ACC20-0086 RY CUJB LA ....... Pl.Al 8 0()( 77, P C£S ikNU 6 A. Of n CURRENT PUBUC RCCOROS Of' OU V AL CQJ NT'I' fl ORI O A CERMCO TO; ~AS R Bl.£050£ Tt 11{.[)RA mu: l CC CO Tl[ N')UR.A.>,j C( AN f un, LEGEND: Q • !irt 1/1' '-.IINI ~T AM!'l.> -fll UI • • f QHJ 1/1" 111\lN PIP[ ,.:, l0l" ~lC • no, (Ulilt.S:. Ol!U!_.. HOm>) ■ •·••· co«:i•nl _.,, •JC • MA CD0fl0N[I> 0 • .xx:, H NCI • ~, n N« I'( PO,,l 17 a.tl~A~ P l• "°"'11 T~ ~ • IIO'<J O Rl'tl{.l!SE OJllvAJIJI![ PCC "UIIT QJ ror,,?OJN() CU"'<,ATUII( 0 . i:Aftr Q f'•.C~ LO V 81.JX)r • !. .... - VI .,. I LOl I i.00< • w~ \\ ,o..\'Y'\ ~o-d \e\ I S~S t.cx s---\-?o..i--'( )e.rrac-e... --:\:1:-17 \958'-0000 Ray I h, . S URVEY ING, 1m: tfu ON TE@ LANO SUR~YS 0 OAT£ Of flCLD SUR~ Y CERF ·---• .,,, 0 CONSTRUCTION SUR\£ 16 OCT NOTES: 1. BUILDING CODE: FLORIDA BUILDING CODE, 6th EDITION (2017) BUILDINGS ARE NOT FOR HIGH-VELOCITY HURRICANE ZONES (HVHZ) UNINHABITED UTILITY SHED UP TO 12' WIDE x UP TO 24' LONG PPTR, TR/TRD800 2. DESIGN LOADING: WIND SPEED: Vult = 155 Vasd = 120 EXPOSURE: C ROOF LIVE LOAD: 20 PSF ROOF DEAD LOAD: 10 PSF FLOOR LIVE LOAD: MIN. 50 PSF (SEE NOTE 5, DETAIL 1, SHEET 3) RISK CATEGORY: I COMPONENT AND CLADDING: ROOF: WIND PRESSURE (psf) (ASD VALUES) (BASED ON 10 SQ FT) WALL: FLORIDA BUILDING APPROVAL NUMBERS-- 29 PSF (ZONE 1) 50 PSF (ZONE 2) 74 PSF (ZONE 3) 34 PSF (ZONE 4) 42 PSF (ZONE 5) 1. WINDOWS BY TAFCO CORP -FLORIDA BUILDING APPROVAL #FL207 43.1. 2. WINDOWS BY SILVER LINE BUILDING PRODUCTS CORP -FLORIDA BUILDING APPROVAL FL 14911.5. 3. LP SMARTSIDE SIDING -FLORIDA BUILDING APPROVAL #FL9190.6. 4. ROOF UNDERLAYMENT BY WOODLAND INDUSTRIES INC. - FLORIDA BUILDING APPROVAL #FL 17206.1. 5. ROOF UNDERLAYMENT BY GAF -FLORIDA PRODUCT APPROVAL #FL 18686.1 6. SHINGLES BY OWENS CORNING -FLORIDA BUILDING APPROVAL #FL 10674.1. 7. SHINGLES BY GAF -FLORIDA PRODUCT APPROVAL #FL 10124.1 8. INNOVATIONS MANUFACTURING, INC. TRANSOM WINDOWS - FLORIDA BUILDING APPROVAL #FL 17667.1. 9. FLOOD SOLUTIONS, LLC FLOOD VENTS (IF REQ'D)- FLORIDA BUILDING APPROVAL #FL 17588.1. 10. OX PAPERBOARD MICHIGAN, LLC THERMO-PLY SHEATHING -FLORIDA BUILDING APPROVAL #FL 16391.1. 11. TUFF SHED, INC DOORS -FLORIDA BUILDING APPROVAL #FL22202.1, #FL22202.2, #FL22202.3, #FL22202.4 HEADER NAILING: HEADER TO STUD-4-16d END NAIL DOUBLED HEADER -16d@ 16" STAGGERED FACE NAIL OVERHANG OPTIONS REFER TO THE TRUSS DESIGN FOR LUMBER SIZE, TRUSS SPACING, PITCH AND PLATE SIZE ~ I-~ I :r ~ (!) ~ w .,.... I .,.... 0 ...J I ...J ex:, ~ COLLAR TIE REQUIRED ONLY AT 12' WIDE SHEDS, SEE TRUSS CALCULATIONS SEE SHEET 3 FOR STEEL FLOOR WITH ANCHOR DETAIL OR FOUNDATION DETAIL FLORIDA APPROVED OWENS CORNING OAKRIDGE 30 YEAR ~ SHINGLES -FL 10674.1-R12 I -OR- FLORIDA APPROVED THOMPSON ARCHITECTURAL METALS CO. METAL ROOFING -FL5218.1-R2 SEE THE TRUSS CONNECTION DETAIL -DETAIL 4 WALL FRAMING TO BE 2 x 4 SPF #2 OR BETTER@ 16" O.C. IF BUILDING IS LOCATED IN A FLOOD ZONE THEN FLOOD VENTS AND PRESSURE TREATED STUDS ARE REQUIRED ~-=----'t-t-~l-------u-P_T_o_1_2_•_-o•-· w_1_D_E ______ ~ 1 ---ONE SQ INCH VENT C:O . --. FOR EVERY ONE SQ FT OF BUILDING DOUBLE TOP PLATE CRIPPLES (IF REQ.) HEADERS FOR OPENINGS UP TO 3'-0" USE (2) 2x4 SPF #2 2x4 WINDOW SILL FLOOR DECKING G) ~A~lb.~ING SECTION ---DOUBLE TOP PLATE -----CRIPPLES (IF REQ.) ------~HEADERS FOR OPENINGS UP TO 4'-0" USE (2) 2x4 SPF #2 OPENINGS 4'-1" TO 6'-0" USE (2) 2x6 SPF #2 OPENINGS 6'-1" TO 8'-0" USE (2) 2x8 SPF #2 KING STUD TRIMMER (3) 2X6 SPF#2 16d@ 12" O.C. HEADERASSY KING STUDS (2) 16d@ 12" O.C. STAGGERED NAILING: BASE PLATE KING STUD BASE PLATE FLOOR DECKING TRIMMER STUD -ON THE INSIDE 8d@ 12" O.C. TRIMMER STUD RAFTER SIMPSON H1 OR USP RT15 FOR 6'-10' WIDE SIMPSON H2.5A OR USP RTTA FOR 12'WIDE WALL TOP PLATES STUDS (;\ TRUSS TO WALL ~ CONNECTION DETAIL SCALE: N. T.S. KING STUD TOE NAIL WITH (3) 18d NAILS, (2) ONE SIDE, (1) OTHER SIDE HEADERS FOR: TRIMMER STUD KING STUDS OPENINGS UP TO 6'-0" USE (2) 2x4 SPF #2 OPENINGS 6'-1" TO 8'-0" USE (2) 2x6 SPF #2 REFER TO SHEET 2 FOR WALL AND ROOF SHEATHING NAILING. FOR WINDOW OPENINGS UP TO 3'-0" FOR OPENINGS UP TO 8'-0" FOR OPENINGS UP TO 8'-0" REFER TO THE DOOR DETAIL (SHEET 2) FOR THE DOOR DESIGN MAX WALL HEIGHT FOR EACH SHED: PPTR -7'-8 1/4" (92 1/4") TR/TRD800 -7'-8 1/4" 92 1/4" TUFF SHED Storage Buildings & Garages fflTUFF SHED, MFG. FACILITIES ~ WINDOW HEADER DETAIL ~ FOR SIDE WALLS SCALE: N.T.S. ~ DOOR HEADER DETAIL \E.9' FOR SIDE WALLS SCALE: N.T.S. Order#. P.O.# THESE DRAWINGS AND THE TUFF SHED, INC. -------------------11 DESIGN ARE THE PROPERTY ~ TRIPLE HEADER DETAIL \E.9' FOR SIDE WALLS SCALE: N. T.S. Customer: Drawn By: PK OF TUFF SHED, INC. THESE ENGINEERING DEPARTMENT ---------a----------DRAWINGS ARE FOR A Site Address: Date: 12/6/16 BUILDING TO BE SUPPLIED -----------11 AND BUil T BY TUFF SHED. Checked By: ANY OTHER USE IS -----------11 FORBIDDEN BY BOTH TUFF Building Size:w,oTH-LENGTH-HEIGHT-sa.FT.AREA Date: SHED AND THE ENGINEER OF RECORD. Scale: N.T.S. RICHARD J. WILLS, P.E. RWILLS@TUFFSHED.COM 1777 S. HARRISON STREET DENVER, COLORADO 80210 (303) 753-8833 EXT. 96315 r,;\ HEADER DETAIL FOR \::!) ENDWALLS SCALE: N.T.S. TITLE BUILDING SECTIONS DRAWING NO. FL-PPTR-TR800-01 HEADER FRAMING DETAILS REV. LEVEL 01 FBC, 6th EDITION (2017) 155C SHEET 1 PAGE 1 OF 4 16 OCT 3/8 SMART SIDE NAILING REQUIREMENTS USE THESE NAILING TABLES FOR THE PPTR AND TR/TRD800 DRAWINGS SIDE WALL EDGE NAILING REQUIREMENTS END WALL EDGE NAILING REQUIREMENTS MARK MAX. MARK WALLS END SIDE COMB. MIN TOTAL WALLS END SIDE MAX. MIN TOTAL BEING WALL WALL OPENING COMBINED BEING WALL WALL COMB. COMBINED USED WIDTH LENGTH EDGE NAILING (NOTE 2) SHEAR WALL USED WIDTH LENGTH EDGE NAILING OPENING SHEAR WALL NO OPENINGS ALONG THE WALL NO OPENINGS ALONG THE WALL 6' 6'-18' 8d NAILS @ 6" O.C. 0' 6'-18' 6' 6'-8' 8d NAILS @ 6" O.C. 0' 6' 8' 8'-22' 8d NAILS @ 6" O.C. 0' 8'-24' 6' 10'-14' 8d NAILS @ 4" O.C. 0' 6' 10' 10'-24' 8d NAILS @ 6" O.C. 0' 10'-24' 6' 16'-18' 8d NAILS @ 3" O.C. 0' 6' 12' 12'-24' 8d NAILS @ 6" O.C. 0' 12'-24' 8' 8'-12' 8d NAILS @ 6" O.C. 0' 8' ■ MIN 2'-4" RTN WALLS ON EACH END OF WALL-■MIN 2'-4" WALL SEGMENT 8' 14'-18' 8d NAILS @ 4" O.C. 0' 8' 6' 6'-18' 8d NAILS (ii) 6" O.C. UP TO 12' 4' 8' 20'-22' 8d NAILS @ 3" O.C. 0' 8' 8' 8'-22' 8d NAILS <@ 6" O.C. UP TO 12' 6' 10' 10'-14' 8d NAILS @ 6" O.C. 0' 10' 8' 8'-22' 8d NAILS I >4"O.C. UP TO 12' 4' 10' 16'-20' 8d NAILS @ 4" O.C. 0' 10' 10' 10'-24' 8d NAILS I 26"O.C. UP TO 12' 7' 10' 22'-24' 8d NAILS @ 3" O.C. 0' 10' 10' 10'-24' 8d NAILS< 24"O.C. UP TO 12' 5' 12' 12'-16' 8d NAILS @ 6" O.C. 0' 12' 12' 12'-24' 8d NAILS< > 6"O.C. UP TO 12' 9' 12' 18'-24' 8d NAILS @ 4" O.C. 0' 12' 12' 12'-24' 8d NAILS @ 4" O.C. UP TO 12' 6' ■ MIN 2'-4" RTN WALLS ON EACH END OF WALL-■MIN 2'-4" WALL SEGMENT *6' 6'-9' 8d NAILS @ 3" O.C. 3' SEE NOTE 3 ROOF SHEATHING (7/16" OSB) 6' 10' 8d NAILS @ 4" O.C. (BS) 3' 2'6" (NOTE 6) WIDTH LENGTH FIELD NAILING EDGE NAILING 6' 12'-14' 8d NAILS @ 3" O.C. (BS) 2'6" (NOTE 6) 6' 6'-18' 8d NAILS@ 12" O.C 8d NAILS @ 4" O.C. 3' 8' 8d NAILS <@ 4" O.C. 3' 8' 8'-24' 8d NAILS@ 12" O.C 8d NAILS @ 4" O.C. 8'-10' 5' 8' 12'-14' 8d NAILS (ii) 3" O.C. 3' 5' 10' 10'-24' 8d NAILS@ 12" O.C 8d NAILS @ 4" O.C. 8' 18'-22' 8d NAILS @ 4" O.C. (BS) 3' 5' 12' 12'-24' 8d NAILS@ 12" O.C 8d NAILS @ 4" O.C. 8' 24' 8d NAILS @ 3" O.C. (BS) 3' 5' 8' 8' 8d NAILS @ 4" O.C. 4' 4' NOTES: 8' 10' 8d NAILS @ 3" O.C. 4' 4' 1. USE 8d COMMON OR GALVANIZED BOX NAILS. 8' 12'-18' 8d NAILS @ 4" O.C. (BS) 4' 4' 8' 20'-22' 8d NAILS @ 3" O.C. (BS) 4' 4' 10' 10' 8d NAILS (ii) 6" O.C. 3' 7' 10' 12'-14' 8d NAILS <@ 4" O.C. 3' 7' TABLE NOTES: 10' 16'-18' 8d NAILS @ 3" O.C. 3' 7' 8d NAILS (ii) 4" O.C. (BS) 10' 20'-24' 3' 7' 1. NAILING IS FOR 3/8" SMARTSIDE PANEL OR 3/8" SMARTSIDE 10' 10'-12' 8d NAILS (ii) 4" O.C. 4' 6' WITH FOIL BACKER. 10' 14'-16' 8d NAILS <@ 3" O.C. 4' 6' 2. NO SINGLE OPENING GREATER THAN 8'-0" 10' 18'-24' 8d NAILS (@ 4" O.C. (BS) 4' 6' 3. * 6' WIDE X 6'-9' LENGTH BUILDINGS ARE BASED ON 3-SIDED DIAPHRAGM. THE END WALL OPPOSITE OF THE OPENING MUST 10' 10' 8d NAILS @ 3" O.C. 6' 4' BE FULLY SHEATHED, IN THE 3-SIDED DIAPHRAGM CASES ~NO 10' 12'-22' 8d NAILS @ 3" O.C. (BS) 6' 4' OPENINGS~ AND NAILED AS SPECIFIED. THE END WALL WI H 12' 12'-16' 8d NAILS c z4"O.C. 4' 8' THE OPEN NG DOES NOT HAVE A MIN. RETURN WALL ON EACH 12' 18'-22' Bd NAILS ( ~3"O.C. 4' 8' SIDE OF THE OPENING. 4. USE COMMON OR GALVANIZED BOX NAILS WITH A MINIMUM 12' 24' 8d NAILS I > 4" O.C. (BS) 4' 8' LENGTH OF 2 1/2". 12' 12' 8d NAILS @ 4" O.C. 6' 6' 5. FIELD NAILING FOR 3/8" SMARTSIDE: 8d @ 12" O.C. 12' 14'-16' Bd NAILS @ 3" O.C. 6' 6' 6. ON THESE BUILDINGS 6' X 10'-18' THE 3' DOOR IN THE END 12' 18'-24' 8d NAILS @ 4" O.C. (BS) 6' 6' WALL WILL NEED TO BE OFF SET. THERE WILL BE A 2'6" PANEL 12' 12'-22' 8d NAILS @ 3" O.C. (BS) 8' 4' ON ONE SIDE AND A 6" PANEL ON THE OTHER SIDE OF THE DOOR. 7. (BS)-DESIGNATES WALLS THAT NEED TO BE SHEATHED ON BOTH SIDES. Order#. P.O.# THESE DRAWINGS AND THE TUFF SHED, INC. TITLE DRAWING NO. TUFF SHED DESIGN ARE THE PROPERTY Customer: Drawn By: PK OF TUFF SHED, INC. THESE ENGINEERING DEPARTMENT FL-PPTR-TR800-01 GENERAL NOTES DRAWINGS ARE FOR A Storage Buildings & Garages Date: 12/6/16 BUILDING TO BE SUPPLIED RICHARD J. WILLS, P.E. REV. LEVEL 01 Site Address: AND BUil T BY TUFF SHED. RWILLS@TUFFSHED.COM fflTUFF SHED, MFG. FACILITIES Checked By: ANY OTHER USE IS FORBIDDEN BY BOTH TUFF 1777 S. HARRISON STREET FBC, 6th EDITION (2017) SHEET 2 Building Size:w,oTH-LENGTH-HEIGHT-sa. FT.AREA Date: SHED AND THE ENGINEER OF DENVER, COLORADO 80210 RECORD. (303) 753-8833 EXT. 96315 155C Scale: N.T.S. PAGE 2 OF 4 16 OCT #12-14X3"HEXHEAD~ SELF-DRILLING SCREWS ~ 3/4" APA OR TECO RATED T&G FLOOR DECKING. 2X6 STEEL JOISTS -- @ 24" 0C #10 X 3/4" PAN ---~-- HEAD SELF-DRILLING SCREWS (2 PER TAB) VENT HOLES @ 24" OC. OPTIONAL LEVELING BLOCKS 2X6 STEEL TRACK EACH END BASE PLATE SCREW SPACING WIDTH SPACING 6'-12' 8" O.C. G) ~=~-~-L SHED BASE DETAIL SIDING TRIM 3/8" CARRIAGE BOLT (GRADE 2) OT17SWB -OR- OT24SWB STUD 1. STEEL SHED FOUNDATION: 600T125-054 -16 GAUGE STEEL TRACKS G140 ZINC COATED 600S137-054 -16 GAUGE STEEL JOISTS G140 ZINC COATED @24"0.C. (SUPPLIER: ALLIED STUDCO (JOIST: 600S137-054 / TRACK: 600T125-054) ICC ER-4943P. 2. 3/4" APA OR TECO RA TED TONGUE AND GROOVE FLOOR DECKING. 24" MAX PANEL SPAN. STAGGER PANEL LAYOUT. 3. FASTEN FLOOR DECKING TO JOIST & TRACKS USING #8 x 1-5/8" ZINC PLATED SCREWS@ 12" 0.C. NO BLOCKING REQUIRED. ALL EDGES SHALL LIE ON FLOOR JOISTS. STAGGER PANEL LAYOUT PER APA CONDITION 1. 4. FASTEN SOLE PLATE THROUGH FLOOR DECKING INTO JOISTS OR TRACKS WITH #12-14 X 3" GALVANIZED SELF-DRILLING SCREWS. REFERENCE SPACING CHART. 5. ALLOWABLE FLOOR LIVE LOAD: 75 PSF FOR STEEL JOISTS CONTINUOUSLY SUPPORTED. 50 PSF FOR JOISTS ON BLOCKS AS SHOWN. 6. USE OPTIONAL CONCRETE BLOCKS AS REQUIRED TO LEVEL BUILDING: SUGGESTED SIZES: 2" x 8" x 16", 4" x 8" x 16", OR 8" x 8" x 16". BLOCKS UNDER JOISTS SPACED @ 8'-0" O.C. MAXIMUM. BLOCKS UNDER TRACK SPACED @ 4'-0" O.C. MAXIMUM. KWIK BOLT ANCHORS (INTO CONCRETE) RE: DETAIL 3 SHEET 3 3/8" NYLON WIDTH LENGTH QTY LOCK NUT BASEPLATE FLOOR PLY 6' 6' 8' 8' 8' 10' 10' 12' 12' 6'-10' 6 12'-18' 8 8'-14' 6 16'-20' 8 22'-24' 10 10'-16' 6 18'-24' 8 12'-18' 6 20'-24' 8 ATTACH BRACKET TO STUDS THRU HOLE IN ANCHOR PLATE WITH 3/8"0 x 4" CARRIAGE BOLT AND LOCKNUT 0 I ct) END WALL AUGER ANCHOR COMPONENTS BY OLIVER TECHNOLOGIES • PART NUMBERS: OT3644BGMP-5/8" X 36" (36" IMBED) GALVANIZED AUGER REPORT NO. RAD-3060 OT17SWB -SIDEWALL BRACKET FOR USE WITH THRU BOLTS REPORT NO. LO-FJ90129-A -OR- OT24SWB -SIDEWALL BRACKET FOR USE WITH THRU BOLTS REPORT NO. LO-FJ90129-B • WORKING LOAD FOR ANCHOR SYSTEM IS 3,150 LBS WITH THE MAXIMUM LOAD OF 4,725 LBS AUGER ANCHORS WIDTH LENGTH #OF ANCHORS SIDING TRIM ANCHOR BRACKET TO BE FLUSH WITH 6' 6'-18' 4ANCHORS 8' 8'-24' 4ANCHORS 10' 10'-24' 6ANCHORS 12' 12'-24' 6ANCHORS 4-ANCHORS PROVIDE (1)AT EA. CORNER OF THE BUILDING. 6-ANCHORS PROVIDE (1)AT EA. CORNERS OF THE BUILDING AND (1) AT THE CENTER OF EA. SIDE WALL. 0 !~<?,_-~R ANCHOR DETAIL EDGE OF TRIM UNHEATED SPACE ANCHOR BOLT & P.T. SILL PLATE PER NOTES BELOW #4 CONTINUOUS TOP&BOTTOM CONTINUOUS FOOTING NOTES 1. TOP OF SLAB TO BE 6" MIN. ABOVE GRADE. SLAB REINFORCEMENT SHALL BE WWF 6X6 W1.4xW1.4. LOCATE AT MID-DEPTH OF SLAB. -OR- SLAB REINFORCEMENT SHALL BE FIBERMESH 150 OR BLENDED FIBERMESH150. FIBERMESH SHOULD BE DISPERSED UNIFORMLY THROUGH CONCRETE W/ MIN. 1 POUND PER CUBIC YARD OF CONCRETE. 2. ALL FOOTING FORMS SHALL BE INSPECTED FOR SIZE AND REINFORCING BEFORE POURING CONCRETE. 3. FOOTINGS SHALL BEAR ON UNDISTURBED NATURAL, COMPETENT SOIL, OR PROPERLY COMPACTED STRUCTURAL FILL. ALLOWABLE SOIL BEARING PRESSURE IS 1000 PSF AT 12" BELOW GRADE. 4. CONCRETE: MINIMUM 28 DAY COMPRESSIVE STRENGTH, fc = 2500 PSI. 5. REINFORCING STEEL: A615, GRADE 40 OR GRADE 60. ALL REINFORCING STEEL SHOWN TO BE CONTINUOUS MAY BE LAPPED A MINIMUM OF 38 BAR DIAMETERS OR 24" MINIMUM, WHICHEVER IS LARGER. 6. SEISMIC DESIGN CATEGORY: A A. ATTACH PRESSURE TREATED SOLE PLATE TO THE FOOTING USING 1/2" DIA X 7" LONG SIMPSON TITEN ANCHOR WITH WASHERS. 1/2" HIL Tl KWIK BOLT TZ STAINLESS STEEL 304 N z NOTES: ..-:!!:--+-------"~"'"-"..-:-+.-'- 1. ANCHORS TO BE KWIK BOLT TZ, 304 SS B. EXPANSION BOLTS SHALL BE EMBEDDED AT LEAST 5" INTO THE CONCRETE AND SHALL BE SPACED NOT MORE THAN 6' OC. C. THERE SHALL BE A MINIMUM OF 2 BOLTS PER SOLE PLATE PIECE WITH 1 BOLT LOCATED NOT MORE THAN 12" NOR LESS THAN 7 BOLT DIAMETERS FROM EACH END OF EACH PIECE. A MINIMUM OF 4 BOLTS ARE REQUIRED PER SIDE OF THE BUILDING. EMBEDMENT DEPTH = 2~" MIN. EDGE DISTANCE= 6" ANCHOR SPACING: RE: KWIK BOLT ANCHORS TABLE, SHEET 3 STEEL SHED BASE 4"CONCRETE PAD (MIN) 2. PROVIDE (1) ANCHOR AT EA. CORNER OF THE BUILDING. THE REMAINING ANCHORS EQUALLY SPACED ALONG THE LENGTH OF THE BUILDING. (1/2 THE REMAINING ANCHORS ON EA. LENGTH c:t:: • ...J a.. ~~ C') 8" THICKENED SLAB ® ~!~N~yvALL BRACKET DETAIL SIDE EQUALLY SPACED). MIN. 0 Ss>~_fRETE FOUNDATION DETAIL TUFF SHED Order#. P.O.# THESE DRAWINGS AND THE --------------------11 DESIGN ARE THE PROPERTY Custom;.::e..:...:r:________ Drawn By: PK OF TUFF SHED, INC. THESE ----------o DRAWINGS ARE FORA Storage Buildings & Garages fflTUFF SHED, MFG. FACILITIES Date: 12/6/16 BUILDING TO BE SUPPLIED ----------1 AND BUil T BY TUFF SHED. Checked By: ANY OTHER USE IS ----------1 FORBIDDEN BY BOTH TUFF -B-ui-ld-in_g_S-iz_e_:w-io-TH--L-EN-GT-H--H-EIG-HT--s-a-.FT-.AREA-Date: SHED AND THE ENGINEER OF 1-----------1 RECORD. Scale: N.T.S. Site Address: TUFF SHED, INC. ENGINEERING DEPARTMENT RICHARD J. WILLS, P.E. RWILLS@TUFFSHED.COM 1777 S. HARRISON STREET DENVER, COLORADO 80210 (303) 753-8833 EXT. 96315 NOTE: FOR BUILDINGS 18' AND LONGER OR ANY BUILDING DESIGNED AS A 3-SIDED DIAPHRAGM, ADD SIMPSON SSTB16 ANCHORS AND HDU2 HOLD DOWNS AT EACH CORNER OF THE END WALLS. FOLLOW MANUFACTURER'S INSTALLATION INSTRUCTIONS. TITLE DETAILS FBC, 6th EDITION (2017) 155C DRAWING NO. FL-PPTR-TR800-01 REV. LEVEL 01 SHEET 3 PAGE 3 OF 4 16 OCT co T"" --T"" 3'-0" T"" T"" T"" 3X4 20 PLATES 1 EACH SIDE 3X4 20 PLATES 1 EACH SIDE N --T"" r--. I ;.. 5'-0" 10'-0" 6'-0" 3X4 20 GA PLATES 1 EACH SIDE 3X4 20 GA PLATES 1 EACH SIDE (0 T"" 3X4 20 GA PLATES --LO T"" 1 EACH SIDE C\I 3'-0" I ;.. C\I f:e r--. 0 I N T"" --T"" T"" C\I 3X4 20 GA PLATES 1 EACH SIDE 3X4 20 GA PLATES T"" T"" I ;.. 3X4 20 GA PLATES 1 EACH SIDE 6'-0" 1 EACH SIDE 3X6 20 GA PLATES 1 EACH SIDE 4'-0" 8'-0" co DESIGN LOADS: TOP CHORD LIVE LOAD = 20 PSF TOP CHORD DEAD LOAD = 10 PSF COLLAR TIE DEAD LOAD = 5 PSF NOTES: FBC, 6th EDITION (2017), 2012 IBC ANSI/TPI 1-2007 TRUSSES TO BE SPACED @ 24" OC MATERIAL TO BE 2X4 SPRUCE PINE FIR GRADE #2 OR BETTER PLATES ARE TO BE PRESSED IN THE WOOD PER TPI. REP MEMBER INCREASE: YES LUMBER D.O.L.: 1.25 WIND: ASCE 7-10, 155 mph, Exposure C, D.O.L.=1.60 6' SPAN REACTIONS: MAX. VERTICAL: 180 LBS. MAX. UPLIFT: -150 LBS. NOTE: 6'-0" 12'-0" TRUSS MAY BE USED ON BUILDING LENGTHS UP TO 12FT UNLESS CEILING JOIST OR OTHER TENSION TIE IS PROVIDED. 8' SPAN REACTIONS: MAX. VERTICAL: 255 LBS. MAX. UPLIFT: -195 LBS. NOTE: co T"" --T"" T"" C\I TRUSS MAY BE USED ON BUILDING LENGTHS UP TO 14FT UNLESS CEILING JOIST OR OTHER TENSION TIE IS PROVIDED. 10' SPAN REACTIONS: MAX. VERTICAL: 300 LBS. MAX. UPLIFT: -250 LBS. NOTE: T"" --T"" T"" C\I TRUSS MAY BE USED ON BUILDING LENGTHS UP TO 16FT UNLESS CEILING JOIST OR OTHER TENSION TIE IS PROVIDED. PLATES ARE MANUFACTURED BY EAGLE METAL PRODUCTS, ICC-ES #ESR-1082. ALL PERSONS FABRICATING, HANDLING, ERECTING OR INSTALLING THIS TRUSS ARE TO DO SO IN ACCORDANCE TO THE RECOMMENDATIONS OF THE LATEST VERSION OF THE BCSI. TUFF SHED 0 der # P.O.# THESE DRAWINGS AND THE r · ________ 1------------i DESIGN ARE THE PROPERTY Customer: Drawn By: PK OF TUFF SHED, INC. THESE =.:...:. ________ ---------; DRAWINGSAREFORA Storage Buildings & Garages fflTUFF SHED, MFG. FACILITIES Site Address: Date: 12/6/16 BUILDING TO BE SUPPLIED 1------------t AND BUil T BY TUFF SHED. Checked By: ANY OTHER USE IS 1------------i FORBIDDEN BY BOTH TUFF B "Id" s· Date: SHED AND THE ENGINEER OF u1 mg 1ze:w,0TH -LENGTH -HEIGHT -sa. FT. AREA RECORD. Scale: N.T.S. TUFF SHED, INC. ENGINEERING DEPARTMENT RICHARD J. WILLS, P.E. RWILLS@TUFFSHED.COM 1777 S. HARRISON STREET DENVER, COLORADO 80210 (303) 753-8833 EXT. 96315 3X6 20 GA PLATES 1 EACH SIDE 12'-0" 12' SPAN REACTIONS: MAX. VERTICAL: 420 LBS. MAX. UPLIFT: -290 LBS. NOTE: TRUSS MAY BE USED ON BUILDING LENGTHS UP TO 20FT UNLESS CEILING JOIST OR OTHE TENSION TIE IS PROVIDED. MAXIMUM DEFLECTION (12 FT. SPAN) VERT LL: 0.06 in. VERT TL: 0.08 in. TITLE TRUSS DETAILS FBC, 6th EDITION (2017) 155C DRAWING NO. FL-PPTR-TR800-01 REV. LEVEL 01 SHEET 4 PAGE 4 OF 4