380 Seminole Rd ACRS21-0036 HVACOWNER:ADDRESS:CITY:STATE:ZIP:
HINSON ERIC V 1106 W APACHE ST NORMAN OK 73069
COMPANY:ADDRESS:CITY:STATE:ZIP:
Buehler Air Conditioning 207 20th ST N JACKSONVILLE
BEACH FL 32250
TYPE OF
CONSTRUCTION:
REAL ESTATE
NUMBER:ZONING:BUILDING USE
GROUP:SUBDIVISION:
170425 0000 SALTAIR SEC 02
JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK:
380 SEMINOLE RD MECHANICAL RESIDENTIAL
HVAC install 2-ton 20K-BTU AHU $4687.00
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
AC AND REFRIGERATION 455-0000-322-1000 2 $16.00
FURNACES AND HEATING 455-0000-322-1000 20000 $24.00
MECHANICAL BASE FEE 455-0000-322-1000 0 $55.00
STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN
YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT
MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU
INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT.
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
1 of 2Issued Date: 2/23/2021
PERMIT NUMBER
ACRS21-0036
ISSUED: 2/23/2021
EXPIRES: 8/22/2021
MECHANICAL RESIDENTIAL HVAC
PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
TOTAL: $99.00
2 of 2Issued Date: 2/23/2021
PERMIT NUMBER
ACRS21-0036
ISSUED: 2/23/2021
EXPIRES: 8/22/2021
MECHANICAL RESIDENTIAL HVAC
PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
DESCRIPTION ACCOUNT QTY PAID
PermitTRAK $99.00
ACRS21-0036 Address: 380 SEMINOLE RD APN: 170425 0000 $99.00
MECHANICAL $95.00
AC AND REFRIGERATION 455-0000-322-1000 2 $16.00
FURNACES AND HEATING 455-0000-322-1000 20000 $24.00
MECHANICAL BASE FEE 455-0000-322-1000 0 $55.00
STATE SURCHARGES $4.00
STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00
TOTAL FEES PAID BY RECEIPT: R14978 $99.00
Printed: Tuesday, February 23, 2021 11:00 AM
Date Paid: Tuesday, February 23, 2021
Paid By: Buehler Air Conditioning
Pay Method: CREDIT CARD 426387262
1 of 1
Cashier: CG
Cash Register Receipt
City of Atlantic Beach
Receipt Number
R14978
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Feb-15 15:50:05
Right-Suite® Universal 2021 21.0.03 RSU00000 Page 1
...s\MISC Builders\Model 1400 - 2968 Ernest St.rup Calc = MJ8 Front Door faces: N
Job:Project Summary Date:
Entire Building Jonathan JacobsBy:
Jonathan Jacobs
13930 SE 124th St, Ocklawaha, FL 32179 Phone: 386-503-0449 Email: MechaniCalcs@gmail.com Web: ineedHVACcalcs.com or MechaniCalcsLLC.com
Project Information
A.J. Wells Roofing & ConstructionFor:
2968 Ernest St, Jacksonville, FL 32205
Model 1400Notes:
Design Information
Jacksonville NAS, FL, USWeather:
Winter Design Conditions Summer Design Conditions
Outside db °F38 Outside db °F96
Inside db °F70 Inside db °F75
Design TD °F33 Design TD °F21
Daily range L
Relative humidity %50
Moisture difference gr/lb44
Heating Summary Sensible Cooling Equipment Load Sizing
Structure Btuh12874 Structure Btuh16974
Ducts Btuh0 Ducts Btuh0
Central vent (49 cfm)1764 Btuh Central vent (49 cfm)Btuh1129
Outside air Outside air
Humidification Btuh0 Blower Btuh0
Piping Btuh0
Equipment load Btuh14638 Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load Btuh18103
Method Latent Cooling Equipment Load SizingBlower door
Shielding / stories 3 (partial) / 1
50 Pa / 1180 cfmPressure / AVF Structure Btuh1377
Ducts Btuh0
Central vent (49 cfm)Btuh1479
CoolingHeating Outside air
14001400Area (ft²)Equipment latent load Btuh2856
1770517705Volume (ft³)
Air changes/hour 0.180.31 Equipment Total Load (Sen+Lat)Btuh20959
Equiv. AVF (cfm)1366 Req. total capacity at 0.85 SHR ton1.8
Heating Equipment Summary Cooling Equipment Summary
Make Goodman Mfg.Make Goodman Mfg.
Trade GOODMAN Trade GOODMAN
Model GSZ140241K Cond GSZ140241K
AHRI ref 201664153 Coil ASPT25B14A
AHRI ref 201664153
Efficiency 8.2 HSPF Efficiency 12.0 EER, 14.5 SEER
Heating input Sensible cooling Btuh18903
Heating output Btuh @ 47°F23200 Latent cooling Btuh3336
Temperature rise °F0 Total cooling Btuh22239
Actual air flow cfm0 Actual air flow cfm816
Air flow factor cfm/Btuh0 Air flow factor cfm/Btuh0.048
Static pressure in H2O0.50 Static pressure in H2O0.50
Space thermostat Load sensible heat ratio 0.86
Capacity balance point = 27 °F
Backup: Goodman Mfg.
Input = 5 kW, Output = 17061 Btuh, 100 AFUE
2021-Feb-15 15:50:05
Right-Suite® Universal 2021 21.0.03 RSU00000 Page 1
...s\MISC Builders\Model 1400 - 2968 Ernest St.rup Calc = MJ8 Front Door faces: N
Job:Manual S Compliance Report Date:
Entire Building Jonathan JacobsBy:
Jonathan Jacobs
13930 SE 124th St, Ocklawaha, FL 32179 Phone: 386-503-0449 Email: MechaniCalcs@gmail.com Web: ineedHVACcalcs.com or MechaniCalcsLLC.com
Project Information
A.J. Wells Roofing & ConstructionFor:
2968 Ernest St, Jacksonville, FL 32205
Cooling Equipment
Design Conditions
°F76.3Entering coil DB:Btuh18103Sensible gain:°F95.8Outdoor design DB:
°F63.6Entering coil WB:Btuh2856Latent gain:°F76.8Outdoor design WB:
Btuh20959Total gain:°F75.0Indoor design DB:
cfm816Estimated airflow:%50Indoor RH:
Manufacturer's Performance Data at Actual Design Conditions
Split ASHPEquipment type:
GSZ140241K+ASPT25B14AModel:Goodman Mfg.Manufacturer:
cfm816Actual airflow:
% of load104Btuh18877Sensible capacity:
% of load118Btuh3362Latent capacity:
%85SHR:% of load106Btuh22239Total capacity:
Heating Equipment
Design Conditions
°F70.0Entering coil DB:Btuh14638Heat loss:°F37.5Outdoor design DB:
°F70.0Indoor design DB:
Manufacturer's Performance Data at Actual Design Conditions
Split ASHPEquipment type:
GSZ140241K+ASPT25B14AModel:Goodman Mfg.Manufacturer:
cfm0Actual airflow:
°F27Capacity balance:% of load158Btuh23200Output capacity:
°F-99Economic balance:Btuh0Supplemental heat required:
Elec stripBackup equipment type:
Model:Goodman Mfg.Manufacturer:
cfm0Actual airflow:
°F21Temp. rise:% of load117kW5.0Output capacity:
Meets all requirements of ACCA Manual S.
2021-Feb-15 15:50:05
Right-Suite® Universal 2021 21.0.03 RSU00000 Page 1
...s\MISC Builders\Model 1400 - 2968 Ernest St.rup Calc = MJ8 Front Door faces: N
Job:Duct System Summary Date:
Entire Building Jonathan JacobsBy:
Jonathan Jacobs
13930 SE 124th St, Ocklawaha, FL 32179 Phone: 386-503-0449 Email: MechaniCalcs@gmail.com Web: ineedHVACcalcs.com or MechaniCalcsLLC.com
Project Information
A.J. Wells Roofing & ConstructionFor:
2968 Ernest St, Jacksonville, FL 32205
CoolingHeating
External static pressure in H2O0.50in H2O0.50
Pressure losses in H2O0.28in H2O0.28
Available static pressure in H2O0.22in H2O0.22
Supply / return available pressure 0.073 / 0.147 in H2O in H2O0.073 / 0.147
Lowest friction rate in/100ft0.134in/100ft0.134
Actual air flow cfm816cfm0
Total effective length (TEL)ft165
Supply Branch Detail Table
Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv
Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk
st221.912.2VlFx0x07.00.21514903096cAttic-A
st19.520.1VlFx0x04.00.24880163cBath 2
st119.221.5VlFx0x06.00.1808401748cBed 2
st126.327.4VlFx0x06.00.1379501981cBed 3
st127.627.3VlFx0x06.00.1349501981cBed 4
st111.118.8VlFx0x04.00.245190403cFoyer
st228.017.3VlFx0x05.00.1627701591cKitchen_Living
4.66.3VlFx0x05.00.6707701591cKitchen_Living-A
st220.49.2VlFx0x05.00.2487701591cKitchen_Living-B
0.04.0VlFx0x04.01.81480163cLaundry
st27.89.9VlFx0x04.00.4141024cMWIC
st28.413.1VlFx0x04.00.342120251cMaster Bath
st221.213.9VlFx0x07.00.20911502389cMaster Bed
Supply Trunk Detail Table
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk
st1 Peak AVF 0 302 0.134 553 10.0 0x0 VinlFlx
st2 Peak AVF 0 430 0.162 547 12.0 0x0 VinlFlx
2021-Feb-15 15:50:05
Right-Suite® Universal 2021 21.0.03 RSU00000 Page 2
...s\MISC Builders\Model 1400 - 2968 Ernest St.rup Calc = MJ8 Front Door faces: N
Return Branch Detail Table
Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk
rb9 0x 00 95 107.8 0.136 356 7.0 x0 0 VlFx rt2
rb10 0x 00 95 107.9 0.136 356 7.0 x0 0 VlFx rt2
rb1 0x 00 265 109.8 0.134 485 10.0 x0 0 VlFx rt2
rb11 0x 00 84 107.3 0.137 428 6.0 x0 0 VlFx rt2
rb7 0x 00 149 49.5 0.296 557 7.0 x0 0 VlFx rt1
rsb1 0x 00 128 59.4 0.247 479 7.0 x0 0 VlFx rt1
Return Trunk Detail Table
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk
rt2 Peak AVF 0 539 0.134 686 12.0 0x0 VinlFlx rt1
rt1 Peak AVF 0 816 0.134 600 5.8 14x14 RectFbg
2021-Feb-15 15:50:05
Right-Suite® Universal 2021 21.0.03 RSU00000 Page 1
...s\MISC Builders\Model 1400 - 2968 Ernest St.rup Calc = MJ8 Front Door faces: N
Job:Static Pressure and Friction Rate Date:
Entire Building Jonathan JacobsBy:
Jonathan Jacobs
13930 SE 124th St, Ocklawaha, FL 32179 Phone: 386-503-0449 Email: MechaniCalcs@gmail.com Web: ineedHVACcalcs.com or MechaniCalcsLLC.com
Project Information
A.J. Wells Roofing & ConstructionFor:
2968 Ernest St, Jacksonville, FL 32205
Available Static Pressure
CoolingHeating
(in H2O)(in H2O)
0.500.50External static pressure
Pressure losses
00Coil
00Heat exchanger
0.050.05Supply diffusers
0.030.03Return grilles
0.200.20Filter
00Humidifier
00Balancing damper
00Other device
0.220.22Available static pressure
Total Effective Length
ReturnSupply
(ft)(ft)
313Measured length of run-out
2415Measured length of trunk
8328Equivalent length of fittings
11055Total length
165Total effective length
Friction Rate
CoolingHeating
(in/100ft)(in/100ft)
OK0.134OK0.134Supply Ducts
OK0.134OK0.134Return Ducts
Fitting Equivalent Length Details
4AE=55, 11C=40, 11G=5, 11G=5, 1A=35, 11G=5, VelAdj=-117: TotalEL=28Supply
6L=20, 11C=40, 11G=5, 6C1=10, 8D3=65, 11G=5, 5A=40, VelAdj=-102: TotalEL=83Return
Job #:
Performed by Jonathan Jacobs for:
A.J. Wells Roofing & Construction
2968 Ernest St
Jacksonville, FL 32205
Jonathan Jacobs
13930 SE 124th St
Ocklawaha, FL 32179
Phone: 386-503-0449
ineedHVACcalcs.com or MechaniCalcsLLC.com MechaniC...
Scale: 1 : 78
Page 1
Right-Suite® Universal 2021
21.0.03 RSU00000
2021-Feb-15 15:50:07
...\Model 1400 - 2968 Ernest St.rup
N
First
Bed 3
Bed 4
Foyer
Bath 2
Bed 2
Laundry
Kitchen_Living
Master Bed
MWIC
Master Bath
10 x 8
115 cfm
8 x 4
12 cfm
8 x 4
1 cfm
10 x 6
84 cfm
10 x 6
95 cfm
8 x 4
8 cfm
10 x 6
95 cfm
10 x 6
77 cfm
10 x 6
77 cfm
10 x 6
77 cfm
8 x 4
19 cfm
Split ASHP Goodman Mfg.
GOODMAN GSZ140241K
ASPT25B14A
14 x 8
128 cfm
14 x 14
265 cfm
14 x 8
95 cfm
14 x 8
95 cfm
14 x 8
84 cfm
Ø7 "
Ø7 "
Ø6 "
14 x 14
Ret Riser
14 x 14
Ø12 "
Ø7 "
8 x 4
8 cfm
Ø5 "
Ø4 "
Ø7 "
Ø5 "
Ø4 "
Ø10 "
Ø5 "
Ø4 "
Ø12 "
Ø4 "
Ø10 "
Ø6 "
Ø6 "Ø6 "
Ø4 "
Ø7 "
To Attic
Job #:
Performed by Jonathan Jacobs for:
A.J. Wells Roofing & Construction
2968 Ernest St
Jacksonville, FL 32205
Jonathan Jacobs
13930 SE 124th St
Ocklawaha, FL 32179
Phone: 386-503-0449
ineedHVACcalcs.com or MechaniCalcsLLC.com MechaniC...
Scale: 1 : 78
Page 2
Right-Suite® Universal 2021
21.0.03 RSU00000
2021-Feb-15 15:50:07
...\Model 1400 - 2968 Ernest St.rup
N Second
Attic
Ø6 "
Ret Riser
14 x 14
40 CFM Fresh Air
14 x 8
149 cfm
Ø7 "10 x 8
149 cfm