Loading...
760 Redfin Dr RESO21-0012 Enclose Screen PorchOWNER:ADDRESS:CITY:STATE:ZIP: BOYD TRAYWICK AND ANNE MARIE DUFFIE 760 REDFIN DR ATLANTIC BEACH FL 32233-3902 COMPANY:ADDRESS:CITY:STATE:ZIP: TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 171310 0000 ROYAL PALMS UNIT 02 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 760 REDFIN DR RESIDENTIAL OTHER SINGLE OR TWO FAMILY RESIDENTIAL OTHER ENCLOSE SCREEN PORCH $6000.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL Notes: All runoff must remain on-site during construction. 2 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL Notes: Roll off container company must be on City approved list. Approved list can be obtained at the Building Department at City Hall. Roll off container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 3/15/2021 PERMIT NUMBER RESO21-0012 ISSUED: 3/15/2021 EXPIRES: 9/11/2021 RESIDENTIAL OTHER PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BLDG 2ND PLAN REVIEW FEE 455-0000-322-1006 0 $50.00 BUILDING PERMIT 455-0000-322-1000 0 $85.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $42.50 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.66 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $182.16 3 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration, including sod, is required. 4 PUBLIC WORKS RUNOFF INFORMATIONAL Notes: All runoff must remain on-site. Cannot raise lot elevation. 5 PUBLIC WORKS DECKING REMOVED INFORMATIONAL Notes: All old decking and debris must be removed from job site by Owner. 2 of 2Issued Date: 3/15/2021 PERMIT NUMBER RESO21-0012 ISSUED: 3/15/2021 EXPIRES: 9/11/2021 RESIDENTIAL OTHER PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 DESCRIPTION ACCOUNT QTY PAID PermitTRAK $182.16 RESO21-0012 Address: 760 REDFIN DR APN: 171310 0000 $182.16 BLDG SUBSEQUENT PLAN REVIEW FEES $50.00 BLDG 2ND PLAN REVIEW FEE 455-0000-322-1006 0 $50.00 BUILDING $85.00 BUILDING PERMIT 455-0000-322-1000 0 $85.00 BUILDING PLAN REVIEW $42.50 BUILDING PLAN CHECK 455-0000-322-1001 0 $42.50 STATE SURCHARGES $4.66 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.66 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL FEES PAID BY RECEIPT: R15179 $182.16 Printed: Monday, March 15, 2021 10:09 AM Date Paid: Monday, March 15, 2021 Paid By: BOYD TRAYWICK AND ANNE MARIE DUFFIE Pay Method: CREDIT CARD 433521750 1 of 1 Cashier: CG Cash Register Receipt City of Atlantic Beach Receipt Number R15179 Building Permit Application Updated 10/9/18 City of Atlantic Beach Building Department 800 Seminole Road, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Build i ng-Dept@coab;us **ALL INFORMATION HIGHLIGHTED IN GRAY IS REQUIRED. Job Address: Fl ~mit Number: __________ _ .J Legal Description P =---7:ifl'7fl~"ifi RE#r/7lJio ~ Valuation of Work (Replacement Cost) $r::::1,0 d0 l Heated/Cooled SF / Z-3 Non-Heated/Cooled. ____ _ • Class of Work: ~Iteration • Use of existing/proposed structure(s): ~esidential • If an existing structure, is a fire sprinkler system installed?: ~o • Will tree s be removed in association with ro osed ro·ect? must submit se arate Tree Removal Permit o De/jcribe in detail t he type of work to be performed , F1tcl'~ -J ~i'i-l'h:J "'J-c,?-eu. uf p4.-ll--/-o I.,~ ;,,. c,(~ ,;,{ ( 11. fo "'11:; 111 ii tt'~ /; ~i h,J ~f~e.¥ "f ho""1e, /M-1,,//it·h"""' ~ Pv-r , 1-J ;.,,,e6 lJ r 4,,..,,/ e,/ee:/r-;4,e,I_ ' .. , . Florida Product Approval# _________________ for multiple products use product approval form Prope ·on Name J•---~ ~ - ~--~-~---~-~ Address ~7 1,0 /Z..u(-/2 i "' l}:;::;;vz,~---~ City l State ~ __ )ip ~1:~£~. ,~Phone ! ~Z.I"-"J,--Z,f-1-3'1,tf:1,,,: E-Mail ; · U H-1 Owner or Agent (If Agent, Power of Attorney or Agency Letter Required) __________________ _ Contractor Information Name of Company , ,., Qualifying Agent'---'--='-----~__,--'-~-~ ----=..,.--' Address.'-----c---'"--'------'------==----'--..,------' City"------'---------' Office Phone I Job Site Contact Number State Certification/Registration# f E-Mail -:.:..:..;.;;:..:~;;,;..;,----=..,...,.=~=~==:_=_::::;;:=_ = __ :.n_==,,,,. Architect Name & Phone# _______________________________ _ Engineer's Name & Phone#-.,-,,--------,,-.----------.-------.;;.---------.---- ---..........,. Workers Compensation Insurer J _ OR Exempt g Expiration Date ~--=--~ Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. NOTICE : In addition to the requ irem ents of th is permit, there ma y be add itiona l res triction s applic abl e to thi s prop erty th at may be fou nd in the pu blic records of this cou nty, an d there may be add ition al perm its required from oth er gov ernm ental entiti es such as wat er management dis tricts , state agencie s, or fe de ra l age nc ies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY .BEFORE RECO G VO R JICE OF COMMENCEMENT. [ _ __,..........;;;.._-4-+---+---;f6.L........l,,C,----------[_[ _________ -~-------"'__;__;_~ \\\\lllt ,111 ig atu e of O ner or Agent) (Signature of Contractor) ,,,, Bet '11,,. 1 /' ""~-~~6ci s~n to (or affirmed) before me this 1011--day of ~t{/~0 p...~, 'io'.7.1 ,b o u<-=r1 = ; __ dl\-~7 : = i~,,~~.~'\':...-i\1: <: - . JU'''"''"'P'"' o-\ ~-Cl• ""'~ ,, o.v .. g:;~ -:, u'I~ •• PU~~ 0 ,,,, "l)t~•~~fP~~own OR ,,,,t 11 iii~~dentification Typeofldentification : f:I ol,,1JS.)t. <, rG Signed and sworn to (or affirmed) before me this __ day of ___ __, __ __, by __________ _ (Signature of Notary) [ ] Personally Known OR [ ] Produced Identification Type of Identification : ____________ _ RESO21-0012 e Owner Builder Affidavit City of Atlantic Beach Building Department 800 Seminole Rd, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Building-Dept@coab.us **ALL INFORMATI ON HIGHLIGHTED IN GRAY IS REQUIRED . PERMIT#: ______ _ I. FLORIDA STATUTES; CHAPTER 489, FLORIDA STATUTES, PART 1 "CONSTRUCTION CONTRACTING" REQUIRES OWNER/ BUILDER TO ACKNOWLEDGE THE LAW: DISCLOSURE STATEMENT FOR SECTION 489.103(7), FLORIDA STATUTES: STATE LAW REQUIRES CONSTRUCTION TO BE DONE BY LICENSED CONTRACTORS. YOU HAVE APPLIED FOR A PERMIT UNDER AN EXEMPTION TO THAT LAW . THE EXEMPTION ALLOWS YOU, AS THE OWNER OF YOUR PROPERTY, TO ACT AS YOUR OWN CONTRACTOR EVEN THOUGH YOU DO NOT HAVE A LICENSE. YOU MUST SUPERVISE THE CONSTRUCTION YOURSELF. YOU MAY BUILD OR IMPROVE A ONE OR TWO FAMILY RESIDENCE OR A FARM OUTBUILDING. YOU MAY ALSO BUILD OR IMPROVE A COMMERC IAL BUILDING AT A COST OF $25,000 .00 OR LESS. THE BUILDING MUST BE FOR YOUR USE AND OCCUPANCY. IT MAY NOT BE BUILT FOR SALE OR LEASE . IF YOU SELL OR LEASE A BUILDING YOU HAVE BUILT YOURSELF WITHIN ONE YEAR AFTER THE CONSTRUCTION IS COMPLETE, THE LAW WILL PRESUME THAT YOU BUILT IT FOR SALE OR LEASE, WHICH IS IN VIOLATION OF THIS EXEMPTION . YOU MAY NOT HIRE AN UNLICENSED PERSON AS YOUR CONTRACTOR. YOUR CONSTRUCTION MUST BE DONE ACCORDING TO THE BUILDING CODES AND ZONING REGULATIONS. IT IS YOUR RESPONSIBILITY TO MAKE SURE THAT PEOPLE EMPLOYED BY YOU HAVE LICENSES REQUIRED BY STATE LAW AND BY COUNTY OR MUNICIPAL LICENSING ORDINANCES. II . INJURY LIABILITY; SINCE OWNERS MAY BE LIABLE FOR INJURIES TO WORKERS THEY HIRE, THE BUILDING DEPARTMENT SUGGESTS WORKER'S COMPENSATION INSURANCE BE PURCHASED .. 111 . IRS WITHHOLDING; OWNERS HI RI NG W ORK ERS BECOME EMPLOYERS AND SHOULD ALSO OBSERVE IRS WITHHOLDING TAX AND/OR FORM 1099 REQUIRE M EN TS ON THE WORKERS THEY EMPLOY ON THEIR IMPROVEMENT TRADES. IV. PENALTY; UNLICENSED CONTRACTORS CAN NOT BE EMPLOYED UNDER ANY CIRCUMSTANCES . OWNERS BEING SUBJECT TO $5,000 PENALTY UNDER FLORI DA STATU TE NO. 455-228(1). AN "OCCUPATIONAL LICENSE" IS NOT ADEQUATE . THE OWNER SHOULD PHYSICALL Y SEE THE COUNTY "CERTIFICATE OF COMPETENCY" OR THE FLORIDA "CONTRACTORS CERTIFICATE" TO ASCERTAIN IF A PERSON IS A LICENSED CONTRACTOR . CONTACT THE BUILDING DEPARTMENT (904- 247 -5826 OR BUILDING -DEPT @CO AB.US) IF IN DOUBT . V. ACKNOWLEDGEMENT; I HEREBY ACKNOWLEDGE THAT I HAVE READ THE ABOVE DISCLOSURE STATEMENT AND THAT I COMPLY WITH ALL THE REQUIREMENTS FOR THE ISSUANCE OF AN OWNER-BUILDER PERMIT. Job Address : 71€0 /2dP i ,,; Z>v-; Ye AflA kf,"e., P4A&A Fl-~-Z,v,5.-:J Owner Name: /3 o j)J,f P-Fie . Phone Number: 6 Z/ -2-2-(-?6 ¥z__ MailingAddress:i1~ /2et,/{4, Qy. -City: ,4/(A,,,if/vB ~d. State J Ft; _ 7 zip: ~z7:-,3 Notarized Signature of Owner __,~=~'--1--1-~-=-~.,,L_---------------------- The foregoing instrument was ac:knowle _1-f -=~:;...q.__~, 20.1d._, in the State of Florida, County of bLlltA'.h 1111 s;goatu,eofNotacyPublk 2= £& ,,,,,, ,,,,, / ~,:~C?!!~.~~<t't~ersonally Known OR +1 Produced Identification $~7_,,-.-~o'TAR~ ' i : MY c;onwn. pejf Identification: _f1-1,__·_,._,o"-'e.,"-1C,,u'--"r...,t"---__,_l--'r"=('.:~------------- : : ~oe.2«l4 • : \ No.HH18300 ,• ~: -;.cj)\ ,Q~ -;. --..._.oue\.,9-. ~"'"' ..____oy~ ~,,,. OF f\: ,'-,.,. ,,,,, .... ,,,,, Upda ted 10/24/18 RESO21-0012 NOTICE OF COMMENCEMENT State of _....!..F.......!...../ !Jy-:..:.....:.;-=-tlJ..:::..,_ ____ _ Tax Folio No . ,R-/1/3/{) -0(100 County of----""/)u~~--"-~L.:~-/ ____ _ To Whom It May Concern : The undersigned hereby informs you that improvements will be made to certa in real property, and in accordance with Section 713 of the Florida Statutes, the following information is stated in this NOTICE OF COMMENCEMENT. Legal Description of property being improved : ____________________________ _ Address of property being improved: __,7,'--'6"-'0"'--...:.M,-=:...,,,,L,{t...:.i-'--''1-"'h-CL..Jc-"' tli..,,,~e........,•c...:)'---'-./-..:.J/ 1/M"-"""'-"f_i-=.c,--'--B....:~=d=-.,_t ..:...F-=t.,'---=?_,z.,._'2-.:.......L:J~I,__ General description of improvements: .....,.,bic.c...cde....:..:~-=ffl---'r_t-:...__.::,¥1---_Je;;;.'.¼t'A-'-;~rLf...:.i .:.,.':~1-f,,,__.c,rc..L...=-U#l-...:~~d _ _ .,..f)tJ-=...--cc..t.. _ _;'-"--:c, 1 =-k>-=-_t,;_<"!l_e~:.:::...:...~- li v 45 S~u. Owner: /;p f;)kf{;~ Address: 1GO ~{';;, (hive:. ,4/ft;.,.._fi-~ Fc.--;Jz,,z,-;J; Owner's interest in site of the improvement: _L,&...:::,,,,.,,,.f..:i-AA""'=-"~=:........,*q...--=':..:µc.....::."1.,_,e.--~ ------------- - --- Fee Simple Titleholder (if other than owner): _____________________________ _ Name : _______________________________________ _ Contractor:----------------------------------------- Address: --------------------------------------- Telephone No .: _________ _ Fax No : ___________ _ Surety (if any) _____________________________________ _ Address: _______________________ Amount of Bond$ _________ _ Telephone No : __________ _ Fax No : ___________ _ Name and address of any person making a loan for the construction of the improvements Name: _______________________________________ _ Address:--------------------------------------- Phone No : ___________ _ Fax No: ___________ _ Name of person within the State of Florida, other than himself, designated by owner upon whom notices or other documents may be served : Name :--------------------------------------- Address : ______________________________________ _ Telephone No : __________ _ Fax No : ___________ _ In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713 .06(2) (b), Flor ida Statues . (Fill in at Owner's option) Name : ______________________________________ _ Address :-------------------------------------- Telephone No: __________ _ Fax No : ___________ _ Expiration date of Notice of Commencement (the expiration date is one (1) yea r from the date of recording unless a different date is specified):----------------------------------------- THIS SPACE FOR RECORDER'S USE 0~\\111111111, OWNER tf!tll~ "' ...... ~ONA l:J ,,,,. I I $' ~t-,..;o·TA~ .. ~)i~d: ( Date: 2-l(o '2-oz l $ / J; ief~ in the Coun{y of D~I, State : {My Cotrm. E"IJft8 fFICida, has personally appeared O•<l\,' 0 Du i:i= 1 { - : \ July 06, 2024 ota! Public at Large , State of Florida, County of Duval. ;, ~\No . HH 18300 ••'W/. '!h'mission expires: -.<JJ..,.U,._.ls"tJl-"-0:Y'><....<., _,7""1..._1 '2...=...L.f'--------------- ', ~~nally Known: / or ,.,,, o'••~o~"'P~uced Identification: ..,,O"-'l.,"'-"'111_.£-e..:i'.-c...S,___.,_\ -<i'Gc,,------------,,, FF\.: ,,"" ,,,,,.. .. ,,,, RESO21-0012 NOT FILED PROPERTY ADDRESS: POINTS OF INTEREST: BUYER: SELLER: CERTIFIED TO: CLIENT NUMBER:DATE: SURVEY NUMBER: FIELD WORK DATE:REVISION DATE(S): This is page 1 of 2 and is not valid without all pages. FLOOD INFORMATION: 2001.2461760 REDFIN DRIVE, ATLANTIC BEACH, FLORIDA 32233 :KRZYSTOF P WOJNAROWICZ AND EWA WOJNAROWICZ KRZYSTOF P WOJNAROWICZ AND EWA WOJNAROWICZ 01/23/20 1/20/2020 :KRZYSTOF P WOJNAROWICZ AND EWA WOJNAROWICZ; ATLANTIC COAST TITLE & ESCROW BY PERFORMING A SEARCH WITH THE LOCAL GOVERNING MUNICIPALITY OR WWW.FEMA.GOV, THE PROPERTY APPEARS TO BE LOCATED IN ZONE X. THIS PROPERTY WAS FOUND IN THE CITY OF ATLANTIC BEACH, COMMUNITY NUMBER 120075, DATED 11/02/18. 1. BUILDING OVER D.U.E. 2. SHED OVER D.U.E. 3. CONCRETE OVER D.U.E. PREPARED BY: (REV.0 1/23/2020) REPORT OF SURVEY GENERAL SURVEYOR NOTES: LEGEND: JOB SPECIFIC SURVEYOR NOTES: ELECTRONIC SIGNATURE:PRINTING INSTRUCTIONS: LEGAL DESCRIPTION: This is page 2 of 2 and is not valid without all pages. OFFER VALID ONLY FOR: 2001.2461 :KRZYSTOF P WOJNAROWICZ AND EWA WOJNAROWICZ THE BEARING REFERENCE OF S85°37'27"E IS BASED ON THE SOUTHERLY RIGHT-OF-WAY LINE OF REDFIN DRIVE, ROYAL PALMS UNIT TWO, AS RECORDED IN PLAT BOOK 30, PAGES 94 & 94A, OF THE PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA. LOT 15, BLOCK 9, ROYAL PALMS UNIT TWO, AS RECORDED IN PLAT BOOK 30, PAGES 94 & 94A, OF THE PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA. *Offer valid for fence stakeouts and additions to the existing structures only. Valid only for the buyer as listed on the first page of this survey for up to one year after survey issuance date. Total discount not to exceed $500. 10% off 1. While viewing the survey in Adobe Reader, select the “Print” button under the “File” tab. 2. Select a printer with legal sized paper. 3. Under “Print Range”, click select the “All” toggle. 4. Under the “Page Handling” section, select the number of copies that you would like to print. 5. Under the “Page Scaling” selection drop down menu, select “None.” 6. Uncheck the “Auto Rotate and Center” checkbox. 7. Check the “Choose Paper size by PDF” checkbox. 8. Click OK to print. TO PRINT IN BLACK + WHITE: 1. In the main print screen, choose “Properties”. 2. Choose “Quality” from the options. 3. Change from “Auto Color” or “Full Color” to “Gray Scale”. In complete accordance with Florida Statute 472.025 and Pursuant to the Electronic Signature Act of 1996 or Florida Statute TITLE XXXIX, Chapter 668, if this document was received electronically via PDF, then it has been lawfully Electronically Signed. Therefore, this survey PDF, if authentic, is completely ocial and insurable. In order to validate the “Electronic Signature” of PDF surveys sent via www.surveystars.com, you must use a hash calculator. A free hash calculator is available for download at: www.softpedia.com/get/System/File-Management/Hash-Calculator-Kirill.shtml In order to validate the Electronic Signature of any survey PDF sent via www.surveystars.com: 1. Download the Hash Calculator available at: www.softpedia.com/get/System/File-Management/Hash-Calculator-Kirill.shtml 2. Save the Survey PDF onto your computer from www.surveystars.com or from the email sent from www.surveystars.com. 3. Click the square Browse button in the upper right hand corner of the Hash Calculator to nd and select the saved Survey PDF document, and click the COMPUTE button in the lower right hand corner of the Hash Calculator. 4. Compare the 40 digit string of characters in the SHA-1 line to the 40 digit SHA-1 characters for the survey in the job le in www.surveystars.com which is also printed on the invoice for that survey. 5. If the 40 digit string of SHA-1 characters are exactly the same on the invoice (or in the survey le at www.surveystars.com) as they are in the Hash Calculator, then this PDF is authentic. If the 40 digit string of characters does not match exactly, then this PDF has been tampered with and it is not authentic. 1. The Legal Description used to perform this survey was supplied by others. This survey does not determine or imply ownership. 2. This survey only shows improvements found above ground. Underground footings, utilities and encroachments are not located on this survey map. 3. If there is a septic tank, or drain field shown on this survey, the location is approximate as the location was either shown to Exacta Land Surveyors, LLC. by a third party or it was estimated by metal detection, probing rods, and visual above ground inspection only. No excavation was performed in order to determine the exact and accurate location. 4. This survey is exclusively for the use of the parties to whom it is certified. 5. Additions or deletions to this survey map and report by other than the signing party or parties is prohibited without written consent of the signing party or parties. 6. Dimensions are in feet and decimals thereof. 7. Due to varying construction standards, house dimensions are approximate. 8. Any FEMA flood zone data contained on this survey is for informational purposes only. Research to obtain such data was performed at www.fema.gov. 9. All corners marked as set are at a minimum a ½”diameter, 18” iron rebar with a cap stamped LB# 8291. 10. If you are reading this survey in an electronic format, the information contained on this document is only valid if this document is electronically signed as specified in Chapter 5J- 17.062 (3) of the Florida Administrative Code and Florida Statute 472.025. The Electronic Signature File related to this document is prominently displayed on the invoice for this survey which is sent under separate cover. Manually signed and sealed logs of all survey signature files are kept in the office of the performing surveyor. If this document is in paper format, it is not valid without the signature and original raised seal of a Florida Licensed Surveyor. 11. Unless otherwise noted, an examination of the abstract of title was NOT performed by the signing surveyor to determine which instruments, if any, are affecting this property. 12. The symbols reflected in the legend and on this survey may have been enlarged or reduced for clarity. The symbols have been plotted at the center of the field location, and may not represent the actual shape or size of the feature. 13. Points of Interest (POI’s) are selected above-ground improvements which may be in conflict with boundary, building setback or easement lines, as defined by the parameters of this survey. There may be additional POI’s which are not shown, not called-out as POI’s, or which are otherwise unknown to the surveyor. These POI’s may not represent all items of interest to the viewer. 14. Utilities shown on the subject property may or may not indicate the existence of recorded or unrecorded utility easements. 15. The information contained on this survey has been performed exclusively, and is the sole responsibility, of Exacta Land Surveyors, LLC.. Additional logo or references to third party firms are for informational purposes only. 16. Pursuant to F.S. 558.0035, an individual employee or agent may not be held individually liable for negligence. 17. House measurements should not be used for new construction or planning. Measurements should be verified prior to such activity. Revision Request/Correction to Comments City of Atlantic Beach Building Department 800 Seminole Rd, Atlantic Beach, FL 32233 **All INFORMATION HIGHLIGHTED IN GRAY IS REQUIRED. Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT#: _______ _ -SRevision to Issued Permit OR Corrections to Comments Date: p I r/u--z,,, ~ I ProjectAddress: 1/p{) ~f-;"" 0-v:i-Vt:,,, 'A+l~fie,, Bue,,{. ' n ~:;,~3 Contractor/Contact Name: 8,, h H ; ~-'' Contact Phone: , .. 3 "?/ -'2, ~-t, lf 2- Description of Proposed Revision / Corrections: @ s-,' 11 , '/3:Pl ~·f'c ¼ a-t~ -u,,,IA-.~ ,,..6:d~~ p u-f,,:u,:;.~ 1 tU-r/:.lf.~ -a> -,r;iilefe.d J-t.J f ~ fo ,P~~e,. 1 4 ,P~ # c·npf;,uk l t!-ti?{ ,-,/ ·qms/~u~ d--kd;,t e-PM"t s /.1e-S-Ul-v:3/ for ~11MJ l._1--=Bi-=o:;_·:...• /Ji<"""·;.,:;• .:..'ff.__.__· ~.,_,'.;;.__,; _____ affirm the revision/correction to comments is inclusive of the proposed changes. (printed name) , I )vjU proPQsed revision/corrections add additional square footage to original submittal? .. · No :=[J Yes (additional s.f. to be added : ___________ ) •~propqsed revision(~orre~ions ad~ addi_ti~nal increase in building value to original submittal? ~No JYes (add1t1onal increase m buildmg _value: k ) (Contractormustslgnlfinaeaseinvaluation) *Signature of Contractor/Agent: ~-~'-=.;......~ff'Vo/C:......_..,.__;:;c.;,,.,'-'----==---------------- (Office Use Only) D Approved D Denied D Not Applicable to Department Permit Fee Due$. _____ _ Revision/Ptan Review Comments. ___________________________ _ Department Review Required: Building Planning & Zoning Tree Administrator Public Works Public Utilities Public Safety Fire Services Reviewed By Date Updated 10/17/18 RESO21-0012 l. FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation -Residential Performance Method Project Name : Street: City, State , Zip: Owner: Duffie -760 Redfin Dr 760 Redfin Dr Atlantic Beach , FL , 32233 Builder Name : Permit Office : Atlantic Beach Permit Number: Jurisdiction : 261100 Design Location: FL, Jacksonville County: Duval (Florida Climate Zone 2 ) 1. New construction or existing Addition 2. Single family or multiple family Detached 3. Number of units , if multiple family 4. Numl:ier of Bedrooms;Bedrms In Addition) 0(0) 5. Is this a worst case? No 6. Conditioned floor area above grade (ft2) Conditioned floor area below grade (ft2) 7. Windows(44 .3 sqft.) Description a. U-Factor: Dbl, U=0 .34 SHGC: SHGC=0.21 b. U-Factor: SHGC : c. U-Factor: SHGC: N/A N/A Area We ighted Average Overhang Depth : Area Weighted Average SHGC : 8. Skylights 120 0 Area 44 .27 ft2 ft2 ft2 2.000 ft. 0.210 Area 10. Wall Type~56.0 sqft.) a. Concrete Block -Int lnsul , Exterior b. N/A c. N/A d. N/A 11 . Ceiling Types (120 .0 sqft.) a. Under Attic (Vented) b. N/A c. N/A 12. Ducts a. Sup: Attic, Ret: Attic, AH : Attic 13 . Cooling systems a. Central Unit 14. Heating systems a. Electric Heat Pump Insulation Area R=4.1 256.00 ft 2 R= ft2 R= ft• R= ft2 Insulation Area R=30.0 120.00 ft2 R= ft2 R= ft2 R ft2 6 24 kB tu/hr Efficiency 28.6 SEER:14.00 kBtu/hr Efficiency 28.6 HSPF :8.20 c. U-Factor:(AVG) SHGC(AVG): N/A N/A ft2 15 . Hot water systems -Replacement equipment 9. Floor Types (120 .0 sqft.) a. Slab-On-Grade Edge Insulation b. N/A c. N/A /' Insulation R=0 .0 R= R= Area 120 .00 ft2 ft2 ft2 a. Electric b. Conservation features None 16. Credits ( Glass/Floor Area: 0.369 Total Proposed Modified Loads : 5.38 Total Baseline Loads : 5.55 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida I;: nergy Code. PREPARED BY : C -uc.-:SfA.u6~ E-Calcs Plus , Inc. DATE: January 13, 2021 I hereby certify that this building, as designed, is in compil ance with the Florida Enei d~~---;:::::::::, OWNER/AGENT: _,_;_-=--~.,-J--=o-r+--~...,2'--------- DATE: ~~2--/ Review of the plans and specifications covered by th is calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553 .908 Florida Statutes. BUILDING OFFICIAL: DATE: Cap : 40 gallons EF : 0.950 Pstat PASS -Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50 (R402.4.1.2). -Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. 1/13/2021 3:42 PM 7.0.00 -FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 4 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY C·ARD ESTIMATED ENERGY PERFORMANCE INDEX*= 97 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Num'ber of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft: ) 7. Windows** a. U-Factor: SHGC: b. U-Factor: SH~C: c. U-Factor: SHGC: d. U-Factor: Description Dbl, U=0.34 SHGC=0.21 NIA NIA NIA SHGC: l Area Weighted Average Overhang Depth : Area Weighted Average SHGC: 760 Redfin Dr, Atlantic Beach, FL, 32233 Addition Detached 0(0) No 120 Area 44.27 ft2 ft2 ft2 ft2 2.000 ft. 0.210 10 . Wall Type and Insulation a. Concrete Block -Int lnsul, Exterior b. NIA c. NIA d. NIA 1 ·1. Ceiling Type and insulation level a. Under Attic (Vented) b. NIA t NIA 1 ' 12. Ducts, location & insulation level a. Sup: Attic, Ret: Attic, AH : Attic 13 . Cooling systems a. Central Unit 14. Heating systems a. Electric Heat Pump Insulation R=4.1 R= R= R= Insulation R=30.0 R= R= Area 256.00 ft2 ft 2 ft2 ft2 Area 120.00W. ft• ft• R ft 2 6 24 kBtu/hr Efficiency 28.6 SEER:14.00 kBtu/hr Efficiency 28.6 HSPF:820 ----·-·-·'·8: ·Skylights Description Area , ... 1.~-l:lot W,:!t~J f YStems~-Replacem~.nt equipment a. Electri~ Cap: 40 gallons a. U-Factor(AVG): NIA SHGC(AVG): NIA 9. Floor Types Insulation a. Slab-On-G_rade Edge Insulation R=0 .0 b. NIA R= c. NIA R= ft2 Area 120.00 ft 2 ft2 ft2 ,b. Conservation features None Credits (Performance method) I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. BuilderSignature: ~~--- Address of New Home: 760 &t{f;,,,,,.. #r,'ve Date : 3/>/uu ,. . City/FL Zip: A-/-/AA f ,;c., g 5 2,,2, EF: 0.95 Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 111312021 3:43 PM 7.0.00 -FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 0 PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH, FLORIDA (*REQUIRED) *ProjectAddress: 7/Rt) f4d'{lu, blriV~ /4/~fic., g/Jt11d Fe, ?z,~:33 Permit#: ___________ _ *Owner/Project Name: &tJ ~{-{ -=---__,:::c....:....:....'-!......:=---------------------------- As required by Florida Statute 553.842 and Florida Administrative Code Rule 9B-72, please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product approval may be obtained at: www.floridabuilding.org. Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# A. EXTERIOR DOORS 1. Swinging &~i,,i~ '</. "~tt.ud OS HV!-lt-Pt-~-Z,7-(,? 2. Sliding 3. Sectional 4. Garage Roll-Up 5. Automatic 6. Other B.WINDOWS 1. Single hung MI 55 t/-O 1-1 Vin 11 I t-/ V fl Z-fe, l7b7b .K 2. Horizontal slider 3. Casement 4. Double hung 5. Fixed MI 1~5t/o p;cfu~ v;.,.,., v H V!-lt Pvl f"' f.f'I-, 6.Awning 7. Pass-through 8. Projected 9. Mullion 10. Wind breaker 11. Dual action 12. Other Page 1 of 4 Updated 10/17 /18 ..... Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# E.SHUTTERS 1. Accordion 2. Bahama 3. Storm panels 4. Colonial 5. Roil-up 6. Equipment 7. Other F. STRUCTURAL COMPONENTS 1. Wood connector/anchor 2. Truss plates 3. Engineered lumber 4. Railing 5. Coolers-freezers 6. Concrete admixtures 7. Material 8. Insulation forms 9. Plastics 10. Deck-roof 11.Wail 12.Sheds 13. Other G.SKYUGHTS 1. Skylight ' 2. Other H. NEW EXTERIOR ENVELOPE PRODUCTS 1. S'",'t1{;,,,'i ~~mt'r lla~d,·e. F:b~ u,,,,.,~ 'PM,~, Pt,, I 11,.,z,, 3, z., 2. Page 3 of4 Updated 10/17/18 - In addition to completing the above list of manufacturers, product description and State approval number for the products used on this project, the Contractor shall maintain on the job site and available to the Inspector, a legible copy of each manufacturer's printed specifications and installation instructions along with this Product Approval Sheet. I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the ones listed in this document must be approved by the Building Official. *Contractor Name (Print Name): "l)ul(L·~ *Contractor Signature: ~~mtb -FF *Company Name: _ _..!N'..:....f..:..~..:........ ________________________________________ _ *Mailing Address: _,, ~tl f!.l't:f /i"1 j)y;v~ *City: /1-..f-/~11,f i-c,,, 8~d,. *State: Pl-*Zip Code : ~z-,Z..,3~ *Telephone Number: .:Jvl' ,z,,,z,, f-5(,<-/-z..,, *E-mail Address: ~t'(1AJ!-/1e.---r I@ j""1~ ;/. t:-41...,._ Cell Phone Number: ________________ Fax Number: ________________________ _ Page 4 of4 Updated 10/17/18 - FORM R405-2020 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance) Method Applications for compliance with the 2020 Florida Building Code, Energy Conservation via the Residential Simulated Performance Alternative shall include: This checklist Form R405-2020 report Input summary checklist that can be used for field verification (usually four pages/may be greater) Energy Performance Level (EPL) Display Card (one page) HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7 Mandatory Requirements (five pages) Required prior to CO: Air Barrier and Insulation Inspection Component Criteria checklist (Table R402.4.1.1 - one page) A completed 2020 Envelope Leakage Test Report (usually one page); exception in R402.4 allows dwelling units of R-2 Occupancies and multiple attached single family dwellings to comply with Section C402.5 If Form R405 duct leakage type indicates anything other than "default leakage", then a completed 2020 Duct Leakage Test Report - Performance Method (usually one page) . 12/22/2020 6:45:10 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 RESO21-0012 PROJECT Title: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction:261100 Atlantic Beach 1 Duffie - 760 Redfin Dr Family Type: New/Existing: Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle:0 No 1 120 0 Addition Detached Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: FL , 32233 Atlantic Beach , Duval 760 Redfin Dr Street Address Comment: Building Type:User Cross Ventilation:No Whole House Fan:No TMY Site Design Temp Int Design Temp Heating Design Daily Temp Design Location 2.5 %97.5 %Degree Days Moisture RangeWinterSummer CLIMATE 93 70 75 1281 49 Medium32FL_JACKSONVILLE_INTFL, Jacksonville______ Number Name Area Volume BLOCKS 1 Entire House 120 960 Number Name Area Volume SPACES Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished 1 Addition 120 960 No 0 Yes Yes1Yes #Floor Type Area Tile Wood Carpet FLOORS R-ValueSpacePerimeter 1 120 ft² 1 0 0______Slab-On-Grade Edge Insulatio - - - -032 ft Addition #Type Materials Color Absor. Roof Solar Deck Insul. Pitch ROOF Tested Roof Area Gable Area Emitt Tested EmittSA (deg) Rad Barr 1 Gable or Shed Composition shingles 124 ft² Medium 0.85 0 14.04______No16 ft² 0.9 NoN ATTIC #Type Ventilation Area RBS IRCCVent Ratio (1 in) ______1 Full attic Vented 120 ft² N N150 #Ceiling Type R-Value Area Framing Frac Truss Type CEILING Space Ins Type 1 Under Attic (Vented)30 120 ft² 0.1 Wood______Addition Blown 1/13/2021 3:42 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS #Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 1 4.1 0Addition000108NConcrete Block - Int Insul 0.410Exterior80.0 ft² ____ 2 4.1 0Addition000108SConcrete Block - Int Insul 0.410Exterior80.0 ft² ____ 3 4.1 0Addition000128WConcrete Block - Int Insul 0.410Exterior96.0 ft² ____ #Door Type U-Value AreaStorms DOORS Ornt Space Width Ft In Ft In Height 1 Insulated .39 20 ft² None______S Addition 863 #Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening WINDOWS Overhang Orientation shown is the entered, Proposed orientation. Wall ID Imp 1 N Low-E Double 0.34 0.21 24.0 ft² 2 ft 0 in 0 ft 6 in NoneVinyl None______Yes1 N 2 S Low-E Double 0.34 0.21 12.0 ft² 2 ft 0 in 0 ft 6 in NoneVinyl None______Yes2 N 3 W Low-E Double 0.34 0.21 8.3 ft² 2 ft 0 in 0 ft 6 in NoneVinyl None______Yes3 N Method CFM 50 ACH 50ELASLAScope INFILTRATION ACHEqLA# 96 65.27.000305Wholehouse .11769.89Proposed ACH(50)1 HEATING SYSTEM #System Type Efficiency Capacity DuctsSubtypeBlockSpeed 1 Electric Heat Pump/Existing/c HSPF:8.2 28.6 kBtu/hr ______sys#1Split1 Singl #System Type Efficiency Capacity Air Flow SHR COOLING SYSTEM DuctsSubtypeBlockSubtype 1 Central Unit/Existing/confirme SEER: 14 28.6 kBtu/hr c f m 0.7______sys#1Split1 Singl #System Type EF Cap Use SetPnt Conservation HOT WATER SYSTEM SubType Location 1 Electric 0.95 40 gal 60 gal 120 deg None______None Exterior FSEC Company Name System Model #Collector Model # Collector SOLAR HOT WATER SYSTEM Storage FEFCert #Area Volume None None f t ² ______ 1/13/2021 3:42 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT #Location R-Value Area Location Area ---- Supply -------- Return ---- Leakage Type Handler CFM 25Air QN RLF DUCTS Heat Cool HVAC # TOT OUT CFM25 1 Attic 6 24 ft² Attic 12 ft² Prop. Leak Free Attic 3.6 cfm 0.03 0.50______1 1 --- cfm TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec [ ] Dec [X] Dec[X] Nov [X] Nov [ ] Oct [X] Oct [ ] Sep [ ] Sep [ ] Aug [ ] Aug [ ] Jul [ ] Jul[ ] Jun [ ] Jun [X] Jun [ ] May [ ] May [ ] Apr [X] Apr [X] Mar [X] Mar [X] Feb [ ] Feb [X] Jan [ ] Jan Heating Venting Thermostat Schedule:HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD)AM PM 78 80 78 80 78 78 78 78 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Cooling (WEH)AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD)AM PM 66 68 66 68 66 68 66 68 66 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 Heating (WEH)AM PM 66 68 66 68 66 68 66 68 66 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 Addition 1/13/2021 3:42 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods Florida Building Code, Energy Conservation, 7th Edition (2020) ADDRESS:760 Redfin Dr Atlantic Beach , FL , 32233 Permit Number: The building official shall require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law (Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD. MANDATORY REQUIREMENTS - See individual code sections for full details. R402.4 Air leakage (Mandatory). During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot (1.5 L/s/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 L/s/m2), when tested according to NFRC 400 or AAMA/ WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. R401.3 Energy Performance Level (EPL) display card (Mandatory). 1/13/2021 3:43 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 5 R402.4.3 Fenestration air leakage. R402.4.1.1 Installation. Exception: Site-built windows, skylights and doors. R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors, and outdoor combustion air. Where using tight-fitting doors on factory-built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the fireplace. Where using tight-fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907. Exception: R402.4.1.2 Testing. R402.4.1 Building thermal envelope. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer’s instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required by the code official, an approved third party shall inspect all components and verify compliance. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. SECTION R401 GENERAL SECTION R402 BUILDING THERMAL ENVELOPE MANDATORY REQUIREMENTS - (Continued) Building framing cavities shall not be used as ducts or plenums. Mechanical system piping capable of carrying fluids above 105°F (41°C) or below 55°F (13°C) shall be insulated to a minimum of R-3. R403.4.1 Protection of piping insulation. If heated water circulation systems are installed, they shall be in accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. 1/13/2021 3:43 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5 R403.3.5 Building cavities (Mandatory). R403.4 Mechanical system piping insulation (Mandatory). R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory). SECTION R403 SYSTEMS R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm (0.944 L/s) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. R402.4.4 Rooms containing fuel-burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential. R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes, to be “substantially leak free” in accordance with Section R403.3.3. Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the entire system, including the manufacturer’s air handler enclosure. Registers shall be taped or otherwise sealed during the test. Rough-in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the manufacturer’s air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test. 2. 1. Exceptions: A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. Duct testing is not mandatory for buildings complying by Section 405 of this code. Duct leakage testing is required for Section R405 compliance where credit is taken for leakage, and a duct air leakage Qn to the outside of less than 0.080 (where Qn = duct leakage to the outside in cfm per 100 square feet of conditioned floor area tested at 25 Pascals) is indicated in the compliance report for the proposed design. 2. 1. R403.1 Controls. R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer’s designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted. 1. 2. R403.5.1.1 Circulation systems. R403.5.1.2 Heat trace systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. MANDATORY REQUIREMENTS - (Continued) 1/13/2021 3:43 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 5 R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 ½ inches (89 mm) in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies (Mandatory). R403.5.6.1.1 Automatic controls. Service water-heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting range shall be from 100°F to 140°F (38°C to 60°C). R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water-heating systems to be turned off. R403.5.6.2 Water-heating equipment. Water-heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water-heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water-heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors, and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar water-heating systems should meet the following criteria: Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and Be installed at an orientation within 45 degrees of true south. 1. 2. R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. R403.7 Heating and cooling equipment. R403.7.1 Equipment sizing (Mandatory). Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. When installed to function as a whole-house mechanical ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. R403.6.1 Whole-house mechanical ventilation system fan efficacy. E x c e p t i o n : R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: Where an air handler that is integral to tested and listed HVAC equipment is used to provide whole-house mechanical ventilation, the air handler shall be powered by an electronically commutated motor. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10 otherwise. 1. 2. 3. TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY For SI: 1 cfm = 28.3 L/min.a.When tested in accordance with HVI Standard 916 HRV or ERV In-line fan Bathroom, utility room Bathroom, utility room FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY AIRFLOW RATE MAXIMUM (CFM)(CFM/WATT) a Any Any 10 90 1.2 cfm/watt 2.8 cfm/watt 1.4 cfm/watt 2.8 cfm/watt Any Any <90 Any (CFM) Range hoods Any 2.8 cfm/watt Any MANDATORY REQUIREMENTS - (Continued) R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the power to the heater. Gas-fired heaters shall not be equipped with continuously burning ignition pilots. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: Where public health standards require 24-hour pump operation. R403.10.2 Time switches. Pumps that operate solar- and waste-heat-recovery pool heating systems. Where pumps are powered exclusively from on-site renewable generation.3. 2. 1. 1/13/2021 3:43 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 5 R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Florida Building Code, Energy Conservation—Commercial Provisions in lieu of Section R403. R403.9 Snow melt and ice system controls (Mandatory) Snow- and ice-melting systems, supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F (10°C), and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F (4.8°C). R403.7.1.2 Heating equipment capacity. R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1.A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2.A variable capacity system sized for optimum performance during base load periods is utilized. R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section R403.7, or the closest available size provided by the manufacturer’s product lines. The corresponding latent capacity of the equipment shall not be less than the calculated latent load. Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space. Exceptions: 1. 2. Attached single- and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. When signed and sealed by a Florida-registered engineer, in attached single- and multiple-family units, the capacity of equipment may be sized in accordance with good design practice. The published value for AHRI total capacity is a nominal, rating-test value and shall not be used for equipment sizing. Manufacturer’s expanded performance data shall be used to select cooling-only equipment. This selection shall be based on the outdoor design dry-bulb temperature for the load calculation (or entering water temperature for water-source equipment), the blower CFM provided by the expanded performance data, the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature. R404.1 Lighting equipment (Mandatory). Not less than 90 percent of the lamps in permanently installed luminaires shall have an efficacy of at least 45 lumens-per-watt or shall utilize lamps with an efficacy of not less than 65 lumens-per-watt. R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights. SECTION R404 R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160, Table 2, Standard Rating Conditions-Low Air Temperature. A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas (Mandatory). The energy consumption of electric-powered portable spas shall be controlled by the requirements of APSP-14. ELECTRICAL POWER AND LIGHTING SYSTEMS Page 5 of 51/13/2021 3:43 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software All gas- and oil-fired pool and spa heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. R403.10.4 Gas- and oil-fired pool and spa heaters. Where more than 70 percent of the energy for heating, computed over an operation season, is from site-recovered energy, such as from a heat pump or solar energy source, covers or other vapor-retardant means shall not be required. Exception: Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. R403.10.3 Covers. R403.13 Dehumidifiers (Mandatory Ducted dehumidifiers shall, in addition to conforming to the requirements of Section R403.13, conform to the following requirements: R403.13.1 Ducted dehumidifiers. If installed, a dehumidifier shall conform to the following requirements: 1.The minimum rated efficiency of the dehumidifier shall be greater than 1.7 liters/ kWh if the total dehumidifier capacity for the house is less than 75 pints/day and greater than 2.38 liters/kWh if the total dehumidifier capacity for the house is greater than or equal to 75 pints/day. 2.The dehumidifier shall be controlled by a sensor that is installed in a location where it is exposed to mixed house air. 3.Any dehumidifier unit located in unconditioned space that treats air from conditioned space shall be insulated to a minimum of R-2. 4.Condensate disposal shall be in accordance with Section M1411.3.1 of the Florida Building Code, Residential. 1.If a ducted dehumidifier is configured with return and supply ducts both connected into the supply side of the cooling system, a backdraft damper shall be installed in the supply air duct between the dehumidifier inlet and outlet duct. 2.If a ducted dehumidifier is configured with only its supply duct connected into the supply side of the central heating and cooling system, a backdraft damper shall be installed in the dehumidifier supply duct between the dehumidifier and central supply duct. 3.A ducted dehumidifier shall not be ducted to or from a central ducted cooling system on the return duct side upstream from the central cooling evaporator coil. 4.Ductwork associated with a dehumidifier located in unconditioned space shall be insulated to a minimum of R-6. Project Name: Owner: Builder Name: Permit Office: Jurisdiction:261100 Atlantic Beach Duffie - 760 Redfin Dr Street: City, State, Zip:Atlantic Beach , FL , 32233 760 Redfin Dr Permit Number: Design Location:FL, Jacksonville CH E C K AIR BARRIER CRITERIA A continuous air barrier shall be installed in the building envelope. The exterior thermal envelope contains a continuous air barrier. Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. The junction of the foundation and sill plate shall be sealed. The junction of the top plate and the top of exterior walls shall be sealed. Knee walls shall be sealed. The space between window/door jambs and framing, and skylights and framing shall be sealed. Rim joists shall include the air barrier. The air barrier shall be installed at any exposed edge of insulation. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Narrow cavities Shafts, penetrations Crawl space walls Floors (including above-garage and cantilevered floors) Rim joists Windows, skylights Walls Ceiling/attic General COMPONENT Garage separation Recessed lighting Plumbing and wiring S h o w e r / t u b HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor, wall covering or The air barrier shall be installed behind electrical or communication boxes or air-sealed boxes shall be installed. The air barrier installed at exterior walls adjacent to showers and tubs shall separate them from the showers and tubs. Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Recessed light fixtures installed in the building thermal envelope shall be sealed to the finished surface. Air sealing shall be provided between the garage and conditioned spaces. When required to be sealed, concealed fire sprinklers shall only be sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. C o n c e a l e d Electrical/phone box on exterior walls Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA INSULATION INSTALLATION CRITERIA EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software1/13/2021 3:43 PM Page 1 of 1 Air-permeable insulation shall not be used as a sealing material. The insulation in any dropped ceiling/soffit shall be aligned with the air barrier. Cavities within corners and headers of frame walls shall be insulated by completely filling the cavity with a material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Rim joists shall be insulated. Floor framing cavity insulation shall be installed to maintain permanent contact with the underside of subfloor decking, or floor framing cavity insulation shall be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. and doors on exterior wall requirements Recessed light fixtures installed in the building thermal envelope shall be air tight and IC rated. sprinklers Where provided instead of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exterior walls adjacent to showers and tubs shall be insulated. 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. a Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2020 Florida Building Code, Energy Conservation, 7th Edition Jurisdiction:261100 Permit #: Job Information Builder:Community:Lot:NA Address:760 Redfin Dr City:Atlantic Beach State:FL Zip:32233 Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g. (50 Pascals) in Climate Zones 1 and 2. PERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50) value, as shown on Form R405-2020 (Performance) or R406-2020 (ERI), section labeled as infiltration, sub-section ACH50. ACH(50) specified on Form R405-2020-Energy Calc (Performance) or R406-2020 (ERI):6.000 _________ x 60 ÷ ______________ = ____________960 CFM(50) Building Volume ACH(50) PASS When ACH(50) is less than 3, Mechanical Ventilation installation must be verified by building department. Method for calculating building volume:_____________________________ Retrieved from architectural plans Code software calculated Field measured and calculated R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control m e a s u r e s . 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. Testing Company Company Name: ______________________________________Phone: ________________________ I hereby verify that the above Air Leakage results are in accordance with the 2020 7th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: ____________________________________Date of Test: ______________________ Printed Name of Tester: _________________________________ License/Certification #: _____________________________Issuing Authority: _________________________ 1/13/2021 3:43:34 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 Duct Leakage Test Report Residential Prescriptive, Performance or ERI Method Compliance 2020 Florida Building Code, Energy Conservation, 7th Edition Jurisdiction:261100 Permit #: Job Information Builder:Community:Lot:NA Address:760 Redfin Dr City:Atlantic Beach State:FL Zip:32233 Duct Leakage Test Results System 1 _________ cfm25 System 2 _________ cfm25 System 3 _________ cfm25 Sum of others _________ cfm25 Total of all _________ cfm25 _______ ÷ ____________ = _______Qn120 Total of all Total Conditioned systems Square Footage Prescriptive Method cfm25 (Total) To qualify as "substantially leak free" Qn Total must be less than or equal to 0.04 if air handler unit is installed. If air handler unit is not installed, Qn Total must be less than or equal to 0.03. This testing method meets the requirements in accordance with Section R403.3.3. Is the air handler unit installed during testing?YES ( = .04 Qn)NO ( = .03 Qn) Performance/ERI Method cfm25 (Out or Total) To qualify using this method, Qn must not be greater than the proposed duct leakage Qn specified on Form R405-2020 or R406-2020. Leakage Type selected on Form Qn specified on Form R405-2020 R405-2020 (EnergyCalc) or R406-2020 (EnergyCalc) or R406-2020 PASS FAIL Proposed Leak Free 0.03 Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes. Testing Company Company Name: ______________________________________Phone: ________________________ I hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the selected compliance path as stated above, either the Prescriptive Method or Performance Method. Signature of Tester: ____________________________________Date of Test: ______________________ Printed Name of Tester: _________________________________ License/Certification #: __________________________________Issuing Authority: ________________________ 1/13/2021 3:43:44 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 2021-Jan-13 10:00:41 Rig ht-Su ite® U niv er sal 20 21 21 .0.02 RSU2 8254 Page 1 ... Redfin Dr\Duffie - 760 Redfin Dr 1.11.2020.rup Calc = MJ8 Front Door faces: N Duffie - 760 Redfin DrJob:Manual S Compliance Report Jan 11, 2021Date:Entire House E-Calcs Plus, Inc.By: E-Calcs Plus, Inc. 9250 Corkscrew Rd, Suite 8, Estero, FL 33928 Phone: 239.810.6106 Email: eric@ecalcsplus.com Web: www.ecalcsplus.com License: HERS Rater ID 0757810 Project Information Duffie - 760 Redfin Dr, Bo DuffieFor: 760 Redfin Dr, Atlantic Beach, FL 32233 Cooling Equipment Design Conditions °F76.6Entering coil DB:Btuh20086Sensible gain:°F92.8Outdoor design DB: °F63.5Entering coil WB:Btuh3720Latent gain:°F77.3Outdoor design WB: Btuh23806Total gain:°F75.0Indoor design DB: cfm953Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ASHPEquipment type: WCH4304GKP**+WAHL304B*Model:Grandaire, NordyneManufacturer: cfm953Actual airflow: % of load112Btuh22496Sensible capacity: % of load117Btuh4352Latent capacity: %84SHR:% of load113Btuh26848Total capacity: Heating Equipment Design Conditions °F68.7Entering coil DB:Btuh26213Heat loss:°F31.8Outdoor design DB: °F70.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Split ASHPEquipment type: WCH4304GKP**+WAHL304B*Model:Grandaire, NordyneManufacturer: cfm953Actual airflow: °F31Capacity balance:% of load109Btuh28600Output capacity: °F-49Economic balance:Btuh0Supplemental heat required: Elec stripBackup equipment type: Model:Grandaire, NordyneManufacturer: cfm953Actual airflow: °F16Temp. rise:% of load65kW5.0Output capacity: Meets all requirements of ACCA Manual S. Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jan-13 10:00:41 Rig ht-Su ite® U niv er sal 20 21 21 .0.02 RSU2 8254 Page 1 ... Redfin Dr\Duffie - 760 Redfin Dr 1.11.2020.rup Calc = MJ8 Front Door faces: N Duffie - 760 Redfin DrJob:Project Summary Jan 11, 2021Date:Entire House E-Calcs Plus, Inc.By: E-Calcs Plus, Inc. 9250 Corkscrew Rd, Suite 8, Estero, FL 33928 Phone: 239.810.6106 Email: eric@ecalcsplus.com Web: www.ecalcsplus.com License: HERS Rater ID 0757810 Project Information Duffie - 760 Redfin Dr, Bo DuffieFor:760 Redfin Dr, Atlantic Beach, FL 32233 Notes: Design Information Jacksonville, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F32 Outside db °F93Inside db °F70 Inside db °F75 Design TD °F38 Design TD °F18Daily range M Relative humidity %50Moisture difference gr/lb52 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh20649 Structure Btuh14983 Ducts Btuh5565 Ducts Btuh5103Central vent (0 cfm)Btuh0 Central vent (0 cfm)Btuh0 (none)(none)Humidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh26213 Use manufacturer's data y Rate/swing multiplier 1.00InfiltrationEquipment sensible load Btuh20086 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh2129 Ducts Btuh1591Central vent (0 cfm)Btuh0 CoolingHeating (none)12201220Area (ft²)Equipment latent load Btuh3720 97609760Volume (ft³)Air changes/hour 0.230.45 Equipment Total Load (Sen+Lat)Btuh23806 Equiv. AVF (cfm)3773 Req. total capacity at 0.70 SHR ton2.4 Heating Equipment Summary Cooling Equipment Summary Make Grandaire, Nordyne Make Grandaire, NordyneTradeGRANDAIRETradeGRANDAIRE Model WCH4304GKP**Cond WCH4304GKP**AHRI ref 204862036 Coil WAHL304B* AHRI ref 204862036Efficiency8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling Btuh20020Heating output Btu h @ 47°F28600 Latent cooling Btuh8580 Temperature rise °F27 Total cooling Btuh28600Actual air flow cfm953 Actual air flow cfm953 Air flow factor cfm/Btuh0.036 Air flow factor cfm/Btuh0.047Static pressure in H2O0.50 Static pressure in H2O0.50 Space thermostat Load sensible heat ratio 0.84Capacity ba lance po int = 31 °F Backup: Grandaire, NordyneInput = 5 kW, Output = 17061 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jan-13 10:00:41 Rig ht-Su ite® U niv er sal 20 21 21 .0.02 RSU2 8254 Page 1 ... Redfin Dr\Duffie - 760 Redfin Dr 1.11.2020.rup Calc = MJ8 Front Door faces: N Duffie - 760 Redfin DrJob:Load Short Form Jan 11, 2021Date:Entire House E-Calcs Plus, Inc.By: E-Calcs Plus, Inc. 9250 Corkscrew Rd, Suite 8, Estero, FL 33928 Phone: 239.810.6106 Email: eric@ecalcsplus.com Web: www.ecalcsplus.com License: HERS Rater ID 0757810 Project Information Duffie - 760 Redfin Dr, Bo DuffieFor: 760 Redfin Dr, Atlantic Beach, FL 32233 Design Information InfiltrationClgHtg SimplifiedMethod9332Outside db (°F) AverageConstruction quality7570Inside db (°F) 0Fireplaces1838Design TD (°F) M-Daily range 5050Inside humidity (%) 5234Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Grandaire, Nordyne Make Grandaire, Nordyne Trade GRANDAIRE Trade GRANDAIRE Model WCH4304GKP**Cond WCH4304GKP** AHRI ref 204862036 Coil WAHL304B* AHRI ref 204862036 Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling Btuh20020 Heating output Btu h @ 47°F28600 Latent cooling Btuh8580 Temperature rise °F27 Total cooling Btuh28600 Actual air flow cfm953 Actual air flow cfm953 Air flow factor cfm/Btuh0.036 Air flow factor cfm/Btuh0.047 Static pressure in H2O0.50 Static pressure in H2O0.50 Space thermostat Load sensible heat ratio 0.84 Ca pacity ba lance po int = 31 °F Backup: Grandaire, Nordyne Input = 5 kW, Output = 17061 Btuh, 100 AFUE ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Main 1100 20967 17864 762 848 Addition 120 5246 2222 191 105 Entire House d 1220 26213 20086 953 953 Other equip loads 0 0 Equip. @ 1.00 RSM 20086 Latent cooling 3720 TOTALS 1220 26213 23806 953 953 Job #: Duffie - 760 Redfin Dr Performed by E-Calcs Plus, Inc. for: Duffie - 760 Redfin Dr 760 Redfin Dr Atlantic Beach, FL 32233 E-Calcs Plus, Inc. 9250 Corkscrew Rd, Suite 8 Estero, FL 33928 Phone: 239.810.6106 www.ecalcsplus.com eric@ecalcsplus.com Scale: 1 : 65 Page 1 Ri ght-Sui te® Uni v ersal 2021 21.0.02 RSU28254 2021-Jan-13 10:01:09 ...ie - 760 Redfin Dr 1.11.2020.rup N First Floor Main Addition DUFFIE RESIDENCE760 REDFIN DRATLANTIC BEACH, FL 32233N JACKSONVILLEINTERNATIONAL AIRPORT95I-10 295ARLINGTON EXPJ. TURNER BUTLERSOUTHSIDE BLVD BEACH BLVD ATLANTIC BLVDKERNAN BLVDHODGES BLVDPHILIPS HWY ATLANTIC OCEAN 9A9A295 AG DESIGN GROUP, LLC.ANGEL E. GUERRERO(904)755-30511(REV 03-03-21) 1 ( R E V 0 3 - 0 3 - 2 1 ) DUFFIE RESIDENCE 760 REDFIN DR ATLANTIC BEACH, FL 32233 COPYRIGHT NOTICE THESE PLANS, DESIGNS, AND IDEAS ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF A.E.G. ALL RIGHTS RESERVED. ANGEL E. GUERRERO (904) 755-3051 AG DESIGN GROUP, LLC. 1 A R C H R E V I S I O N S 3 - 0 3 - 2 1 DUFFIE RESIDENCE760 REDFIN DRATLANTIC BEACH, FL 32233N JACKSONVILLEINTERNATIONAL AIRPORT95I-10 295ARLINGTON EXPJ. TURNER BUTLERSOUTHSIDE BLVD BEACH BLVD ATLANTIC BLVDKERNAN BLVDHODGES BLVDPHILIPS HWY ATLANTIC OCEAN 9A9A295 AG DESIGN GROUP, LLC.ANGEL E. GUERRERO(904)755-3051 DUFFIE RESIDENCE 760 REDFIN DR ATLANTIC BEACH, FL 32233 COPYRIGHT NOTICE THESE PLANS, DESIGNS, AND IDEAS ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF A.E.G. ALL RIGHTS RESERVED. ANGEL E. GUERRERO (904) 755-3051 AG DESIGN GROUP, LLC. DUFFIE RESIDENCE 760 REDFIN DR ATLANTIC BEACH, FL 32233 COPYRIGHT NOTICE THESE PLANS, DESIGNS, AND IDEAS ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF A.E.G. ALL RIGHTS RESERVED. ANGEL E. GUERRERO (904) 755-3051 AG DESIGN GROUP, LLC. DUFFIE RESIDENCE 760 REDFIN DR ATLANTIC BEACH, FL 32233 COPYRIGHT NOTICE THESE PLANS, DESIGNS, AND IDEAS ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF A.E.G. ALL RIGHTS RESERVED. ANGEL E. GUERRERO (904) 755-3051 AG DESIGN GROUP, LLC.