Loading...
451 Skate Rd ROOF21-0018 Mod BitOWNER:ADDRESS:CITY:STATE:ZIP: WHITWAM AARON J 451 SKATE RD ATLANTIC BEACH FL 32233-3821 COMPANY:ADDRESS:CITY:STATE:ZIP: HAMMER TIME ROOFING 14286 Beach Blvd JACKSONVILLE FL 32250 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 171524 0000 ROYAL PALMS UNIT 02A3.00 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 451 SKATE RD ROOF NON SHINGLE MODIFIED BITUMEN FLAT ROOF $7500.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $90.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $45.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.03 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $139.03 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 3/10/2021 PERMIT NUMBER ROOF21-0018 ISSUED: 3/10/2021 EXPIRES: 9/6/2021 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 2 of 2Issued Date: 3/10/2021 PERMIT NUMBER ROOF21-0018 ISSUED: 3/10/2021 EXPIRES: 9/6/2021 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 DESCRIPTION ACCOUNT QTY PAID PermitTRAK $139.03 ROOF21-0018 Address: 451 SKATE RD APN: 171524 0000 $139.03 BUILDING $90.00 BUILDING PERMIT 455-0000-322-1000 0 $90.00 BUILDING PLAN REVIEW $45.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $45.00 STATE SURCHARGES $4.03 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.03 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL FEES PAID BY RECEIPT: R15143 $139.03 Printed: Wednesday, March 10, 2021 9:59 AM Date Paid: Wednesday, March 10, 2021 Paid By: HAMMER TIME ROOFING Pay Method: CREDIT CARD 431740495 1 of 1 Cashier: CG Cash Register Receipt City of Atlantic Beach Receipt Number R15143 f^rf - ' j ,, Building Permit Application Updated 10/9/18 a City of Atlantic Beach Building Department ALL INFORMATION 800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY il' IS REQUIRED. Phone: (904) 247-5826IEmail: Building-Dept@coab.us Job Address: 1-/s 1 S:c.tc kJ Permit Number: K000c Z [ — OOil Legal Description 31-/c 17 - as -dg L R4' PT o,4,1„.1 AL., ,,..:. ,4 (a/ S RE# / 7/S dtI- Woo as K t B Valuation of Work(Replacement Cost)$ , t 571) HHeated/Cooled SF Non-Heated/Cooled Class of Work: New Addition Alteration ii4air OMove Demo Pool OWindow/Door Use of existing/proposed structure(s): Commercial idential If an existing structure, is a fire sprinkler system installed?: Yes No Will tree(s) be removed in association with proposed project? Yes (must submit separate Tree Removal Permit) C'Ico Describe in detail the type of work to be performed: R.pa:r 04 J tAw,.,h pal—8v) c -ck Florida Product Approval#for multiple products use product approval form Propert Owner Information I Name Mc rQ 1 (,; vu r M 1Address 1 SkGf- C ci City 1941d,fir 2c&c& State Ft Zip Z a a 3 3 Phone (9oct) 333 -S 310 E-Mail Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) Contractor Information Name of Company nom,.-,ai- l•,4 e echo Qualifying([ ngentctar„r ? Address 1-/L c' Re.,/, 311J Sk l5 -la'6 City ck3ctiv/ 44 State FL Zip 3 ad d Office Phone (40'f) 7/z' -1/Y 1 Job Site Contact Number %'•/ 4,c) off`/©- SS W 3StateCertification/Registration# CC( 13A_41`I J E-Mail )tamrne-fine rt."). 0 .-,„.: I Architect Name&Phone# Engineer's Name&Phone# I l n Workers Compensation Insurer /3. ctcC. (c t,s ,,/I OR Exempt Expiration Date_ B Oda i Application is hereby made to obtain a permit to do the worKand installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS,HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT: i certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN OUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBT A INANCING, CON•.0 WITH YOUR LENDER OR AN ORNE BEFORE EC. ' PIN'. YOUR • ICE,F OMMENCEMENT. ija a _ Sig tur' of 0 er•r Agent)Signature of Contractor) igned nd sworn jor affirmeyl) before e t•is 3 day of Si ne d,,answor to(gr a irme•) be •re - thi 3 day of at , • ket feb'1big, h y 1)-1 b i ° / i1 a: 1 moi CCU4t,,,‘vac Sign. • i - c4F'1"'o iii- '_ - 401.(`, CARMEN E PEET CARMEN E FEET o•• :,. MY COMMISSION#GG 058962 ( c.; MY COMMISSION GG 958962 Personally Known OR ,.- r:o;= EXPIRES;June 10) 4= a Known OR 1,..-..."....,3`: EXPIRES:June 10,2024Z. Produced Identification I 1 I\ -`: °P°* Bonded mx ottyPub34Uhdntwi sei Identification f•!,`•° BondedThruNotaryPubAcUnderwritera ype of Identification: r I fJ - ification: j- r" "` PREPA.RE IN DUPLICATE.Permit Nc. County of 0(0 To whom it may concern: i7?undersigned hereby inf0(7j1$you that IIT1oS'QVenla ^, Cc111 dant wiENT.Section 713 0;i 1aFlorida$iwi ia£,the following informationon is:f real property,^ nta ill b c to lllel t. i , r;and in L_ diad in this NOTICE p; L=ei description of property bei 1- Address.of propery bein_improv ' a.ci u_=Cnpiio.i of Gress 4 ..- s. Owner's interest in site zaf Ehc improvement Fee Simple Titleholder(if other than owner) Address Contractor Iphone Surety(if ani Fa'X?!0. Address Phone No. Amount -of bond i\?l7ic cid address of any ozerc on ma it ?icier)for-Name iLle-dnsErUCi!Dn of the improvements. lid:re•s' Pion=Nn G),No. Name of person within i^? State of Florida.other than himself,.Oani_F°i8^by owner upon whom notices or other documents may be seie ddre- Name i' i0P) cre No. n cdC?iron i himself.owner d>_icna°es:•e iollo:irPrison to receiveell=c copy of the!tenor's Notice es provided in Section 13•o5(7)(by,Florida. 'Statutes. (Fill in=O:•;„er;option). Address Phone No. Nc. xpir?;ion data of Notice ofdifferentdate. Commencement(the=X+n -is specified): airetIon date is one(1)year THIS. SPACE from the date of r cardinG unless FOR RECORDER'S USB Oily„ VIIER a`' I'S,';iii:,;CAM--"MEN PEET E MY COMMISSION GG 958962 c` _ _7 c ?%l/Zjer3i ••-',-!:... vs r..i.3to, EXPIRES:June 10,2024 sone::z=esrec M1 r: . ir, cl, Y Public UnderNtft ra are _=::e accurate that a; a l_ u s,a declarations ha:-. 41nerai b, Doc#2021057063.OR BK 19615 Page 573, a.`ifc= L_ Number Pages: 1 r•ccmc9salc-ezci;_`11—Io' ,; Co:ni of 1111I//J it_Gd-- Recorded 03/04/2021 12:20 PM, tart:'Kn-•a or circ._I_ee!{ c 17_JODY PHILLIPS CLERK CIRCUIT COURT DUVAL COUNTY RECORDING $1000 D 06 ONEMO etc. APPENDIX 1:ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE TABLE DECK APPLICATION TYPE DESCRIPTION PAGE 2A Roof Cladding Design Pressures,Allowable Stress Design,Pasd,Exposure B 3 2A Roof Cladding Design Pressures,Allowable Stress Design,Pasd,Exposure C 4 2A Roof Cladding Design Pressures,Allowable Stress Design,Pasd,Exposure D 5 3 Wood New or Reroof(Tear-Off)A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 6-9 4 Wood New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 10-13 5 Wood New,Reroof(Tear-Off)or Recover D Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 14-17 6 Wood New,Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 18-21 7 Wood New,Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 22-25 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 2. Unless otherwise noted,insulation may be any one layer or combination of FBC Approved(Local or Statewide)board(s)that meet FBC 1505 and,for foam plastic,FBC Chapter 26,when installed with the roof cover. 3. For adhered roof insulation and board-size: Unless otherwise noted,refer to Section 2.2.10.6.2 of FM Loss Prevention Data Sheet 1-29(February 2020). 4. The maximum design pressure for the selected base assembly shall meet or exceed the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. This is already addressed in the tables that follow via"N/A"reference if the baseline system is"Not Applicable"to Zone 1 PRIME design pressure requirements. 5. For mechanically attached components over existing decks,fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 6. Refer to FBC 1511 for requirements and limitations regarding recover installations. For Recover Applications using System Type D,the insulation is optional. 7. Unless otherwise noted,refer to the following references for bonded applications. TABLE 1:MEMBRANE/ADHESIVE COMBINATIONS REFERENCE LAYER MATERIAL APPLICATION BP-AA Base Ply: Glasbase;All Weather/Empire Base,Flexiglas Base,Flintlastic Base 20 Hot asphalt at 20-40 Base and Ply sheets,Asphalt- Applied) Ply: One or more Flintglas Ply 4,Flintglas Premium Ply 6lbs/square Base Ply: Flintlastic Base 20,Flintlastic Poly SMS Base,Flintlastic Ultra Poly SMS Base SBS-AA Ply: One or more Flintlastic Base 20,Flintlastic Poly SMS Base,Flintlastic Ultra Poly SMS Base Hot asphalt at 20-40 SBS,Asphalt-Applied) Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic lbs/square Cap Ply:Premium FR-P CoolStar,Flintlastic GMS,Flintlastic GMS CoolStar Base Ply: Flintlastic Ultra Poly SMS Base,Flintlastic Base 20 T SBS-TA Ply: One or more Flintlastic Ultra Poly SMS Base,Flintlastic Base 20 T Torch-Applied SBS,Torch-Applied) Cap Ply: Flintlastic FR Cap 30 T,Flintlastic FR Cap 30 T CoolStar NEMO ETC,LLC Evaluation Report C40710.12.13-R7 for FL16709-R7 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION Revision 7:09/ 03/2020 2019 NEMO ETC,LLC CertainTeed Flintlastic•Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 1 of 25 NEMO I etc. TABLE 1(CONTINUED):MEMBRANE/ADHESIVE COMBINATIONS REFERENCE LAYER MATERIAL APPLICATION APP-TA Base Ply: One or more Flintlastic APP Base T,Flintlastic STA,Flintlastic STA Plus Torch-Applied APP,Torch-Applied)Cap Ply: Flintlastic STA,Flintlastic STA Plus,Flintlastic GTA,Flintlastic GTA CoolStar,Flintlastic GTA-FR,Flintlastic GTA-FR CoolStar Base Ply: Flintlastic SA PlyBase,Flintlastic SA Mid Ply SBS-SA SBS,Self-Adhering) Ply: Flintlastic SA PlyBase,Flintlastic SA Mid Ply Self-Adhering Cap Ply: Flintlastic SA Cap,Flintlastic SA Cap CoolStar,Flintlastic SA Cap FR,Flintlastic SA Cap FR CoolStar 8. "MOP"=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. 9. The following summary is the basis for the attachment tables herein. Tables 2A through 2C assume the following design parameters as defined in ASCE 7-16. Projects outside these design parameters are not applicable for use within the confines of this Evaluation Report. PARAMETER REFERENCE SYMBOL VALUE Design wind speed(mph)* FBC 1609.3 Vult Various Exposure Category FBC 1609.4.3 N/A B,C or D Topographical factor Section 26.8.2 Kzt 1.0 Wind directionality factor Section 26.6 Kd 0.85 Ground elevation factor Table 26.9-1 Ke 1.0 Roof slope N/A 7 7° Selection of the appropriate design wind speed and exposure category is the responsibility of the user,subject to acceptance by the Authority Having Jurisdiction. NEMO ETC,LLC Evaluation Report C40710.12.13-R7 for F116709-R7 Certificate of Authorization#32455 7`"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 7:09/ 03/2020 02019 NEMO ETC,LLC CertainTeed Flintlastic•Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 2 of 25 NEMO I etc. TABLE 7: WOOD DECKS—NEW CONSTRUCTION OR RE ROOF(TEAR-OFF) SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER N/A"INDICATES THE SYSTEM CANNOT BE USED WITHIN THE PRESSURE ZONE. Base Sheet Roof Cover(Note 7) System Deck Base Ply and/or MDP(psf) Ply No. Note 1)Base Fasteners Attachment Cap Glasbase;Flexiglas;Flintlastic Base 20; Pattern#1:B-inch o.c.at the 4-inch side Min.19/32-inch 32 ga.,1-5/8-inch dia.tin caps with 11 BP-AA,SBS-AA, SBS-AA,SBS-TA W-5 plywood All Weather/Empire Base;Poly SMS ga.annular ring shank nails laps and 8-inch o.c.at three(3)equally SBS-TA or APP-TA or APP-TA 60.0 Base;Ultra Poly SMS Base;Yosemite spaced center rows BASE SHEET ATTACHMENT PATTERN REFERENCES: PATTERN NO: #1(AS-LISTED) 2 3 4 its 6 7 MIN.LAP WIDTH(inch): 4 4 4 4 4 4 4 MAX.LAP FASTENER SPACING(inch o.c.): 8 7 6 6 6 4 4 MIN.#OF EQUALLY SPACED CENTER ROWS: 3 3 3 4 5 4 5 MAX.CENTER ROW FASTENER SPACING(inch o.c.): 8 7 6 6 6 4 4 BASE SHEET ATTACHMENT,SYSTEM W-5: Exposure Enclosure Roof Height(ft)zone Ultimate Design Wind Speed—V.rc(mph) 110 _ 120 130 140 150 160 .. 180 200 1 PRIME #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) 1 1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) h<15 2 1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) 3 3 1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) _ #1(AS-LISTED) #1(AS-LISTED) 2 3 5 1 PRIME #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) 1 1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) 15<h<20 2 1(AS-USTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) 2 3 3 1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) 2 5 6 B Open 1 PRIME #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) 1 1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) 2 20<h<30 2 1(AS-LISTED) #1.(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) 2 5 3 1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) 2 3 5 7 1 PRIME #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) 1 1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) 2 30<h<40 2 1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) 3 5 3 1(AS-LISTED) #1(AS-LISTED) #1(AS-LISTED) 2 3 4 6 N/A NEMO ETC,LLC Evaluation Report C40710.12.13-R7 for FL16709-R7 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 7:09/03/2020 2019 NEMO ETC,LLC CertainTeed Flintlastic•Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 22 of 25 CertainTeed FLINT, LizisTic0 Application Handbook - Third Edition An educational program for professional roofing contractors FUNTL.4S77C APPLICATION SPECIALIST leirF d s x CertainTeed SAINT-GOBAIN 18. Equipment vibration shall be corrected. 19. Masonry surfaces above flashings shall be tuck-pointed and sealed. All horizontal masonry surfaces above the roof membrane shall be adequately protected from weather. 20. All pipes and condensation line supports shall be properly supported with factory supplied pipe supports or pressure treated woodblocking. All supports shall have a protection layer of not less than one layer of Flintlastic modified bitumen membrane. The support shall be designed to allow for pipe movement and shall not be secured through the roof membrane. 21 . Condensation lines shall be formed from ultraviolet light resistant materials and shall terminate at drains or scuppers. Condensate shall not run on the roof surface. 22. The practice of installing only a part of a total roof assembly, known as phasing, can be harmful to the finished roof assembly. CertainTeed will not warrant phased applications. NOTE: Substrates with two or more existing membranes are not eligible for a CertainTeed Warranty. Extended warranties require new construction and/or complete tear-off. Application Over an Existing Membrane After preparing and priming the existing membrane surface spot mop with type Ill or type IV asphalt, forming 12" circles spaced 24" o.c., and install a Yosemite Venting Base Sheet with side laps of 2" and end laps of 6". Asphalt quantity shall be 15 lbs. per square, or greater, depending on the roughness of the existing membrane surface. Granules and grooves shall be facing down. Alternatively, mechanically attach a Yosemite Venting Base Sheet with minimum #12 diameter roofing fasteners and 3" stress plates to meet the design uplift criteria. At a minimum, mechanical attachment shall be placed 12" o.c. on a 3" lap and two staggered rows in the center of the sheet spaced 18" o.c. Insulation shall be solid mopped to buffer sheet. Alternate base sheets may be approved on a job-by-job basis. Contact CertainTeed Technical Services with project data for consideration of alternate base sheets. Rigid insulation may be applied directly to an existing built-up membrane providing the surface has been properly prepared; there is adequate attachment of the existing roof assembly to resist design and/or code require loads and the deck has been adequately leveled to provide full adhesion of the maximum 4' x 4' insulation boards. An initial glaze coat of asphalt can fill minor variations in the deck surface and provide a more suitable surface for the application of rigid insulation board. 16 Roof Relief Vents If roof relief vents are deemed appropriate they should be of a suitable type with minimum 4" flange and weather resistant hood, spaced 20' from roof edge perimeter and every 40' o.c. thereafter. Proper Tools To the professional roofer, the importance of proper tools is understood. However, here's a brief recap of the ideal tools for AI" applying Flintlastic modified bitumen: For torch applications, a U.L. listed torch designed specifically for the application of modified bitumen membrane with U.L. listed high-pressure r' hose, and U.L. listed regulator. Use an appropriate length field torch for applying the field roof membrane, and a "detail" torch for accomplishing flashing details. Propane tank with pressure gauge. At least one ABC type fire extinguisher, fully charged (min. 20 lbs.) per each operating torch and the appropriate number of fire extinguishers at the kettle area if hot asphalt is used. For hot asphalt applications, appropriate asphalt heating, handling and application equipment. Mop size should be not less than 32 ounces. For self-adhering applications, 18" wide, 2"- 4" diameter industrial steel roller for pressing membrane into place; long-handled (standing) roller with 1/8" -1/4" nap for applying primer (1/8" nap for smooth surfaces, 1/4" nap for more porous surfaces); caulk gun for applying beads of FlintBond adhesive; hand-held hot air welding gun such as the Leister Triac- (1 10 volt power required) or Primus Sievert PNS-4- Hot Air Kit; seam probing tool to check for small voids. A roofer's hooked blade knife (the hooked blade is ideal for cutting the membrane). A roofer's trowel with beveled edges and rounded tip (allows smoothing of details without cutting or marking the membrane); trowels that allow adequate room between the roofer's gloved fingers and the warm membrane are the best. Proper Attire Long pants and long sleeved shirts. 17 Leather work shoes with synthetic or smooth leather soles. Leather work gloves that adequately shield the wrist area. Refer also to the "Safety" section on page 53 for information regarding proper work attire. Roof Layout As with most types of roof installations, Flintlastic modified bitumen roof installation begins at the low point of the roof with successive rolls installed so that no laps are against the flow of water. When membrane is applied with hot asphalt, where roof slope is 1" per foot or less, sidelaps are installed perpendicular to the direction of the roof slope. In situations where the roof slope exceeds 1" per foot, rolls are installed with the sidelaps running parallel to the slope direction. APP modified membranes can be installed with sidelaps perpendicular to the slope where roof slope is 2" per foot or less (over 2" install sidelaps parallel to roof slope direction). Additionally, where roof slope exceeds 1" per foot for SBS modified and self-adhering membranes or 2" per foot for APP modified "back-nailing" of membrane is required. Refer to the General Recommendations section of the CertainTeed Commercial Roof Systems Manual for back-nailing guidelines. Endlaps are to be staggered. In multi-ply applications, membrane sidelaps must also be staggered. imilsel k IOW 111,11r ism nprosis mospMwinegypenow ioweari•WOW' Yw•.44 gam (Mow Gig Vest Y.r tttrata CarShoo In multi-ply systems, stagger sidelaps from Stagger field sidelaps from interply and base sheet sidelaps base sheet sidelaps Warning: Flintlastic Modified Bitumen application may require the use of hot asphalt and/or an open flame roofing torch. Improper application practices may cause physical injury to the applicator or damage to the property. Refer to the current CertainTeed Commercial Roof Systems Manual for further information. 18