Loading...
31 Seminole Rd SIGN21-0005 Units A and BOWNER:ADDRESS:CITY:STATE:ZIP: SOLOMON PROPERTIES INC 14255 BEACH BLVD JACKSONVILLE FL 32250 COMPANY:ADDRESS:CITY:STATE:ZIP: Nine Enterprises Inc. dba SIGN-A-RAMA 3633 SOUTHSIDE BLVD JACKSONVILLE FL 32216 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 170667 1000 SALTAIR SEC 01 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 31 SEMINOLE RD SIGN WALL SIGNS FOR UNIT A and UNIT B $8000.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT SIGN WITH OR WITHOUT ELECTRIC 455-0000-322-1000 24 $65.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 ZONING WALL SIGN FEE 001-0000-329-1003 0 $30.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 4/19/2021 PERMIT NUMBER SIGN21-0005 ISSUED: 4/19/2021 EXPIRES: 10/16/2021 SIGN PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 TOTAL: $99.00 2 of 2Issued Date: 4/19/2021 PERMIT NUMBER SIGN21-0005 ISSUED: 4/19/2021 EXPIRES: 10/16/2021 SIGN PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 DESCRIPTION ACCOUNT QTY PAID PermitTRAK $164.00 SIGN21-0005 Address: 31 SEMINOLE RD APN: 170667 1000 $164.00 BUILDING $130.00 SIGN WITH OR WITHOUT ELECTRIC 455-0000-322-1000 24 $65.00 SIGN WITH OR WITHOUT ELECTRIC 455-0000-322-1000 24 $65.00 STATE SURCHARGES $4.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 ZONING PLAN REVIEW $30.00 ZONING WALL SIGN FEE 001-0000-329-1003 0 $30.00 TOTAL FEES PAID BY RECEIPT: R15556 $164.00 Printed: Monday, April 19, 2021 3:05 PM Date Paid: Monday, April 19, 2021 Paid By: Nine Enterprises Inc. dba SIGN-A-RAMA Pay Method: CREDIT CARD 446138194 1 of 1 Cashier: CG Cash Register Receipt City of Atlantic Beach Receipt Number R15556 Final Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: _____________________________________________________ Permit Type ____________________________________________________ Permit No. __________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION UNIT A (LARGER ON LEFT) AND UNIT B (SMALLER ON RIGHT) SIGN21-0005 Revision Request/Correction to Comments **ALL INFORMATION HIGHLIGHTED IN GRAY IS REQUIRED. City of Atlantic Beach Building Department 800 Seminole Rd, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT #: _____________________ Revision to Issued Permit OR Corrections to Comments Date: ________________ Project Address: ____________________________________________________________________________________ Contractor/Contact Name: ____________________________________________________________________________ Contact Phone: ______________________________ Email: _________________________________________________ Description of Proposed Revision / Corrections: __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ I_______________________________ affirm the revision/correction to comments is inclusive of the proposed changes. (printed name)  Will proposed revision/corrections add additional square footage to original submittal? No Yes (additional s.f. to be added: _____________________________)  Will proposed revision/corrections add additional increase in building value to original submittal? No *Yes (additional increase in building value: $____________________) (Contractor must sign if increase in valuation) *Signature of Contractor/Agent: _______________________________________________________ __________________________________________________________________________________________________ (Office Use Only) Approved Denied Not Applicable to Department Permit Fee Due $_______________ Revision/Plan Review Comments_______________________________________________________________________ __________________________________________________________________________________________________ Department Review Required: Building _____________________________________________ Planning & Zoning Reviewed By Tree Administrator Public Works Public Utilities _____________________________________________ Public Safety Date Fire Services Updated 10/17/18 SIGN21-0005 DESIGN CALCULATIONS FOR ATLANTIC COAST APPLIANCE WALL-MOUNTED SIGNS 31A Seminole Rd – Atlantic Beach Index: Pg 1 Cover Pg 2 Wind Loads Pg 3 Anchor Design PE # 67382 Easy Seals Cert Auth # 31124 Engineer's signature and seal valid for pages 1 through 3 Apr 06 2021 Christian Langley GENERAL NOTES: 1.Design is in accordance with the Florida Building Code 7th Edition (2020) for use within and outside the High Velocity Hurricane Zone (HVHZ). 2.Wind loads have been calculated per the requirements of ASCE 7-16 as shown herein. 3.These engineering calculations pertain only to the structural integrity of those systems, components, and/or other construction explicitly specified herein and/or in accompanying engineering drawings. The existing host structure (if any) is assumed to be in good condition, capable of supporting the loaded system, subject to building department approval. No warranty, either expressed or implied, is contained herein. 4.System components shall be as noted herein. All references to named components and installation shall conform to manufacturer's or industry specifications as summarized herein. 5.Where site conditions deviate from those noted herein, revisions may be required or a separate site-specific engineering evaluation performed. 6.Aluminum components in contact with steel or embedded in concrete shall be protected as prescribed in the 2015 Aluminum Design Manual, Part 1. Steel components in contact with, but not encased in, concrete shall be coated, painted, or otherwise protected against corrosion. 7.Engineer seal affixed hereto validates structural design as shown only. Use of this specification by contractor, et. Al, indemnifies and saves harmless this engineer for all costs & damages including legal fees & apellate fees resulting from deviation from this design. 1200 N Federal Hwy, #200 Boca Raton, FL 33432 Easy Seals .com Page 1 CALCULATIONS FOR WALL-MOUNTED SIGNS ASCE 7-16 Design Wind Loads WALL-MOUNTED SIGNS Building Specs V =130 mph Basic wind speed (Vult) Exposure C ASD Load Combo Coeff:0.6 Calculations α =9.5 3-sec gust speed power law exponent Kd =0.85 Directionality factor zg =900'Nominal ht. of atmos. boundary layer Kzt =1.0 Topographic factor Gcpi =0 Internal pressure coeff Ke =1.0 Ground elevation factor A =10 sq ft Tributary area CENTER (Zone 4) CORNER (Zone 5)Kh = Kz qz GCp (4)GCp (5) 15 ft 20.6 psf 26.2 psf 0.85 18.7 -1.10 -1.40 20 ft 21.9 psf 27.9 psf 0.90 19.9 -1.10 -1.40 25 ft 22.9 psf 29.2 psf 0.95 20.9 -1.10 -1.40 30 ft 23.8 psf 30.3 psf 0.98 21.7 -1.10 -1.40 35 ft 24.6 psf 31.3 psf 1.01 22.4 -1.10 -1.40 40 ft 25.3 psf 32.2 psf 1.04 23.0 -1.10 -1.40 45 ft 26.0 psf 33.0 psf 1.07 23.6 -1.10 -1.40 50 ft 26.5 psf 33.8 psf 1.09 24.1 -1.10 -1.40 55 ft 27.1 psf 34.5 psf 1.12 24.6 -1.10 -1.40 60 ft 27.6 psf 35.1 psf 1.14 25.1 -1.10 -1.40 70 ft 23.3 psf 46.6 psf 1.17 25.9 -0.90 -1.80 80 ft 24.0 psf 48.0 psf 1.21 26.6 -0.90 -1.80 90 ft 24.6 psf 49.2 psf 1.24 27.3 -0.90 -1.80 100 ft 25.1 psf 50.3 psf 1.27 27.9 -0.90 -1.80 110 ft 25.6 psf 51.3 psf 1.29 28.5 -0.90 -1.80 120 ft 26.1 psf 52.2 psf 1.32 29.0 -0.90 -1.80 130 ft 26.6 psf 53.1 psf 1.34 29.5 -0.90 -1.80 140 ft 27.0 psf 54.0 psf 1.36 30.0 -0.90 -1.80 150 ft 27.4 psf 54.7 psf 1.38 30.4 -0.90 -1.80 175 ft 28.3 psf 56.6 psf 1.42 31.4 -0.90 -1.80 200 ft 29.1 psf 58.2 psf 1.46 32.3 -0.90 -1.80 250 ft 30.5 psf 61.0 psf 1.53 33.9 -0.90 -1.80 130 mph - Exp ''C'' WALL-MOUNTED SIGNS SIGN HEIGHT ASD WIND PRESSURES Page 2 CALCULATIONS FOR WALL-MOUNTED SIGNS Wall Sign Anchor Design Structure Dimensions & Loading Design wind pressure:P =30.3 psf Sign type: Sign size:A =24.0 sqft (entire cabinet) Wall material:CDX or equiv, thickness to match Min Embed Anchor type/size: Ref: Min Embedment:0.5" Min edge dist:3"Min Spacing:1.5" Anchor tensile capacity:Tcap =179.4 lb (per anchor) Check Anchors for Pullout Total Reaction:Rt =728 lb … = P*A (entire cabinet) No. of anchors req'd:n =4.1 total anchors … = Rt/cap Total anchors required:5 total anchors balanced over cabinet OK, limit to min (6) total. Powers Strap-Toggle, catalog Cabinet Wood 3/8" Toggle Bolt (r) Page 3 36 3 3 S o u t h s i d e B o u l e v a r d Ja c k s o n v i l l e , F L 3 2 2 1 6 Of f : 9 0 4 . 9 9 8 . 8 8 8 0 Fa x : 9 0 4 . 9 9 8 . 8 8 9 6 © 2 0 1 8 10 110V Connection Fastener size: Generally 3/8” to 1/2” X 3” to 6”, based 10 2 Aluminum Square Tube Frame Cabinet Interior Painted White 196” 770” 48” 72” 48” 72” 188”188” Cabinet with Standard 4.3” Return Lettering: Return Color: Black Trimcap Color: Black Face Colors: Blank White Face None Cabinet with Standard 4.3” Return Lettering: Return Color: Black Trimcap Color: Black Face Colors: White, Blue and Green Atlantic Coast Appliance Logo Sign 1 Sq. Feet: 24 sq/ft [(72”W x 48”H) / 144 = 24 ] Linear Frontage: [(770”W ) / 12 = 64 Linear ft] Illuminated Building Sign on Bracket Allowable Signage: 64 sq/ft [64 Linear Feet = 64 Sq Feet] 64 Linear Feet Pr o j e c t : 1 1 8 2 1 A t l a n t i c C o a s t A p p l i a n c e Ad d r e s s : 3 1 A S e m i n o l e R d A t l a n t i c B e a c h , F L 3 2 2 3 3 Da t e : M a r c h 1 7 , 2 0 2 1 D e s i g n e r : B r y a n Sign 1 Sign 2 Sign 2 Sq. Feet: 24 sq/ft [(72”W x 48”H) / 144 = 24] Total Sq. Feet: 48 sq/ft [24+24 = 48 ] t%FTJHOJTJOBDDPSEBODFXJUIUIFSFRVJSFNFOUTPGUIFFla Bldg Code 7th Ed (2020)GPSVTFXJUIJOPVUTJEFUIF)JHI7FMPDJUZ)VSSJDBOF;POF )7); t5IJTFOHJOFFSJOHDFSUJöFTPOMZUIFTUSVDUVSBMJOUFHSJUZPGUIPTFTZTUFNT DPNQPOFOUT BOEPSPUIFSDPOTUSVDUJPOFYQMJDJUMZTQFDJöFEIFSFJOt&MFDUSJDBMOPUFT EFUBJMT TQFDJöDBUJPOTBSFQSPWJEFECZBOEBSFUIFTPMFSFTQPOTJCJMJUZPGUIFFMFDUSJDBMDPOUSBDUPS/PFMFDUSJDBMSFWJFXIBTCFFOQFSGPSNFEBOEOPDFSUJöDBUJPOPGTVDIJTJOUFOEFEt4USVDUVSBMEFTJHONFFUTSFRVJSFNFOUTPG"$* "*4$ "%. /%4  BTBQQMJDBCMFt4UFFMDPNQPOFOUTTIBMMCFDPBUFE QBJOUFE PSPUIFSXJTFQSPUFDUFEBHBJOTUDPSSPTJPOQFS'#$4FDt"MVNDPNQPOFOUTJODPOUBDUXJUITUFFMPSFNCFEEFEJODPODSFUFTIBMMCFQBJOUFEPSQSPUFDUFEBTQSFTDSJCFEJO"%. B PSQMBTUJDOFPQSFOFTQBDFSTQSPWJEFEt"MMFYQPTFEGBTUFOFSTTIBMMCF44PSIBWFBQSPUFDUJWFDPBUJOHGPSDPSSPTJPOQSPUFDUJPOt"MMXFMEJOHTIBMMDPNQMZXJUI"84SFRVJSFNFOUTt4UFFMXFMET&YYFMFDUSPEFTt"MVNJOVNXFMETöMMFSBMMPZt"MVNFYUSVTJPOT5PSTUSPOHFS 6/0 General Notes: 1 20 0 N Fe d e r a l H w y, # 20 0 Bo c a Ra t o n , FL 33 4 3 2 1- 88 8 -3 71 - 3 11 3 Ch r i st i an L a n g l e y F l or i d a P E # 6 7 38 2 Ce r t of Au t h # 3 11 24 ENGINEER’S SIGNATURE Easy Seals easyseals.com AS C E 7 -1 6 WI N D L O A D S : t 4 J H O  ) F J H I U       G U  N B Y t , [ U      , E       (      8B M M  D P N Q P O F O U T    D M B E E J O H  t  ; P O F     ± 2 3. 8 p s f    t  ; P O F     ± 3 0 .3 p s f t 3 J T L  $ B U F H P S Z    4 U S V D U  t " 4 %  - P B E  $ P F G G       t 7      N Q I t & Y Q P T V S F  h $ h APR 06 2021 3/8" TOGGLE BOLTS TO MIN 1/2" PLYWOOD: MIN (2) EACH FRAME = (6) ANCHORS TOTAL MIN (3) FRAMES TOTAL, BAL. 1/4" THRUBOLTS TO FRAME: MIN (6) TOTAL E y SIG N GN GINN 0211 s.colsc eaeaSe EaEaE  P R O R F E SSIONA L E N GGGGGGG I I N EENNNNENNNNNE E 2020EEE220 E 0606E006 R APRAPRRARAPRA  C H H H H R R R R R I S T I A N LAN G EE LL EE LSLL E E E E SS easyeasy E E E S easy E SeS easy Y Y yseyse Y Y asys Y Y yseLLLLIICENSSS EEEE F LO R I D A No. 67382  STATE OF (MIN 1"SQ x 0.125") SIGN21-0005