Loading...
1839 Seminole Rd RERF21-0113 ShingleOWNER:ADDRESS:CITY:STATE:ZIP: RENNIE JANICE BARKLEY TRUST C/O JANICE B RENNIE TRUSTEE ATLANTIC BEACH FL 32233-5915 COMPANY:ADDRESS:CITY:STATE:ZIP: STONEBRIDGE CONSTRUCTION 6956 PHILLIPS PARKWAY DR N JACKSONVILLE FL 32258 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 169630 0500 OCEAN GROVE UNIT 02 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 1839 SEMINOLE RD REROOF SHINGLE Shingle: FL10674 $10927.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $105.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $109.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 4/21/2021 PERMIT NUMBER RERF21-0113 ISSUED: 4/21/2021 EXPIRES: 10/18/2021 REROOF SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 2 of 2Issued Date: 4/21/2021 PERMIT NUMBER RERF21-0113 ISSUED: 4/21/2021 EXPIRES: 10/18/2021 REROOF SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 Final Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: _____________________________________________________ Permit Type ____________________________________________________ Permit No. __________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION DESCRIPTION ACCOUNT QTY PAID PermitTRAK $109.00 RERF21-0113 Address: 1839 SEMINOLE RD APN: 169630 0500 $109.00 BUILDING $105.00 BUILDING PERMIT 455-0000-322-1000 0 $105.00 STATE SURCHARGES $4.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL FEES PAID BY RECEIPT: R15586 $109.00 Printed: Wednesday, April 21, 2021 3:48 PM Date Paid: Wednesday, April 21, 2021 Paid By: STONEBRIDGE CONSTRUCTION Pay Method: CREDIT CARD 446975993 1 of 1 Cashier: CG Cash Register Receipt City of Atlantic Beach Receipt Number R15586 RERF21-0113 DURATION® SERIES SHINGLES INSTALLATION INSTRUCTIONS Instrucciones para la instalación Duration® Premium Shingles TruDefinition® Duration® COOL Plus Shingles TruDefinition® Duration® COOL Shingles TruDefinition® Duration® Designer Colors Collection Shingles TruDefinition® Duration® Shingles Install Instructions | TruDefinition® Duration® Shingles | April 20202 Application Instructions Before installing this product, check local building codes for roofing requirements. These shingles are designed for new or reroofing work over any properly built and supported wood roof deck having adequate nail holding capacity and a smooth surface. Must comply with local building codes. Precautionary Note: The manufacturer will not be responsible for problems resulting from any deviation from the application instructions and the following precautions: •Roof Top Loading: Lay shingle bundles flat. Do not bend over the ridge. •Roof Deck: Minimum 6 inch roof deck boards, minimum 3/8 inch plywood, minimum 7/16 inch OSB, sheathing spaced minimum 1/8 inch and maximum 1/4 inch. Regardless of deck type used, the roofing installer must: 1. Install the deck material in strict compliance with the deck manufacturer’s instructions. 2. Prevent the wood deck from getting wet before, during and after installation. •Ventilation: Must comply with local building codes. •Handling: Use extra care in handling shingles when the temperature is below 40°F. •Storage: Store in a covered, ventilated area at a maximum temperature of 110°F. Bundles should be stacked flat. Do not store near steam pipes, radiators, etc. •Fastener Requirement: Use galvanized steel, stainless steel or aluminum nails minimum 12 gauge shank with 3/8 inch diameter head. Owens Corning Roofing recommends that fasteners comply with ASTM F1667. Must comply with local building codes. All fasteners must penetrate at least 3/4 inch into the wood deck or completely through the deck by a minimum of 1/4 inch. Notice: Owens Corning Roofing requires the use of nails as the method of attaching shingles to wood decking. Instrucciones para la instalación Antes de instalar este producto, verifique los códigos de construcción locales para saber cuáles son los requisitos del techo. Estas tejas están diseñadas para trabajos de techado nuevo o para la reconstrucción de un techo antiguo que posea una plataforma de madera adecuada, con capacidad para sostener clavos y con una superficie lisa. Debe cumplir con los requisitos de los códigos de construcción locales. Nota de precaución: El fabricante no se hará responsable por los problemas que puedan resultar de cualquier desviación de las instrucciones para la instalación de las tejas y de las siguientes notas de precaución: •Carga en los techos: Coloque los paquetes de tejas planos. No los doble sobre la cumbrera. •Estructura base del techo: Placas base de madera con un ancho mínimo de 6 pulgadas; revestimiento mínimo de madera contrachapada de 3/8 pulgadas; paneles de fibra orientada (OSB) de un mínimo de 7/16 pulgadas; espacio de revestimiento mínimo de 1/8 pulgadas y máximo de 1/4 pulgadas. •Cualquiera sea el tipo de estructura base utilizada, el instalador del techo debe: 1. Instalar el material de la estructura base del techo de manera que cumpla con las instrucciones de instalación del fabricante de dicho material. 2. Asegurarse de que la estructura base de madera no se moje antes, durante y después de la instalación. •Ventilación: Debe cumplir con los requisitos de los códigos de construcción locales. •Manipulación: Tenga cuidado especial con la manipulación de las tejas cuando la temperatura sea inferior a 40°F. •Almacenamiento: Conserve en un área cubierta y ventilada a una temperatura máxima de 110°F. Los paquetes deben estar apilados sobre sus caras. No las almacene cerca de tuberías de vapor, radiadores, etc. •Requisitos de los sujetadores: Use clavos de acero galvanizado, acero inoxidable o aluminio, de vástago calibre 12 como mínimo y diámetro de cabeza de 3/8 pulg. Owens Corning Roofing recomienda que los sujetadores cumplan con la norma ASTM F1667. Debe cumplir con los requisitos de los códigos de construcción locales. Todos los sujetadores deben penetrar al menos 3/4 pulg. en la estructura de madera o atravesarla completamente un mínimo de 1/4 pulg. Aviso: Owens Corning Roofing exige el uso de clavos como método preferido para fijar tejas a plataformas de madera. Install Instructions | TruDefinition® Duration® Shingles | April 2020 3 1 2 Self-Adhered Ice & Water Barrier Use an Owens Corning® Self-Adhered Ice & Water Barrier on the eaves in all regions of the country where roofs have had a history of ice and water backup. Apply starting at the eaves edge and extend upslope a minimum of 24 inches from the interior wall line. See Fig. 1. Barrera autoadhesiva resistente al hielo y al agua Utilice la barrera autoadhesiva resistente al hielo y al agua de Owens Corning® en los aleros de todas las regiones del país en las que los techos estén expuestos a filtraciones por causa de la acumulación de agua y hielo. Para la instalación, comience en el borde del alero y extienda hacia arriba un mínimo de 24 pulgadas desde la línea de la pared interior. Ver la Fig. 1. Synthetic Underlayment Standard Slopes 4:12 and Greater: Use an Owens Corning® Synthetic Underlayment or equivalent underlayment meeting ASTM D226, D4869 or D6757. Follow underlayment manufacturer’s application instructions and local building codes. See Fig. 2. Membrana impermeabilizante sintética Pendientes estándar 4:12 y superiores: Use una membrana impermeabilizante sintética Owens Corning o una membrana equivalente que cumpla con ASTM D226, D4869 o D6757. Siga las instrucciones de instalación del fabricante de la membrana impermeabilizante y los códigos de construcción locales. Ver la Fig. 2. 3 Synthetic Underlayment Low Slope 2:12 to Less than 4:12: Use an Owens Corning® Synthetic Underlayment or equivalent underlayment meeting ASTM D226, D4869 or D6757. Underlayment must be installed per the manufacturer’s application instructions and local building codes. Each underlayment course must be overlapped a minimum of 1/2 the width of the underlayment plus 1 inch. See Fig. 3. Or Owens Corning® Self-Adhered Ice & Water Barrier or equivalent with a standard overlap of 3 inches and metal drip edge. See Fig. 3A. Note: See technical bulletin for felt application. Membrana impermeabilizante sintética Pendientes bajas de 2:12 a menos de 4:12: Use una membrana impermeabilizante sintética Owens Corning o una membrana equivalente que cumpla con ASTM D226, D4869 o D6757. La membrana impermeabilizante se debe instalar de acuerdo con las instrucciones del fabricante y los códigos de construcción locales. Cada hilera de membrana impermeabilizante debe superponerse un mínimo de la 1/2 del ancho de la membrana más 1 pulgada. Ver la Fig. 3. O barrera autoadhesiva resistente al hielo y al agua de Owens Corning® o equivalente con una superposición estándar de 3 pulgadas y borde de goteo metálico. Ver la Fig. Fig. 3A . Nota: Vea el boletín técnico para la aplicación de fieltro. Install Instructions | TruDefinition® Duration® Shingles | April 20204 4 Shingle Fastening Pattern Standard Fastening Pattern: Fasteners must be placed in the SureNail® Technology fastening area. See Fig. 4. Six Nail Fastening Pattern: Use 6 fasteners. See Fig. 4A. Mansard or Steep Slope Fastening Pattern: Place fasteners 61/8 inches from bottom edge to secure both layers of the shingle. Fasteners need to be located 61/8 inches above the butt edge of the shingle, regardless of whether they are in the granules or the SureNail® Technology fastening area. See Fig. 4B. REQUIRED: For slopes exceeding 60 degrees or 21 inches per foot, use 6 fasteners and 4 spots of asphalt roof cement per shingle. Apply immediately, one 1 inch diameter spot of asphalt roof cement under each shingle tab. Center asphalt roof cement 2 inches up from bottom edge of shingle tab. See Fig. 4B. Asphalt Roof Cement where required must meet ASTM D4586 Type I or II (Asbestos Free). Note: Please be aware that excessive amounts of asphalt roof cement could blister the shingle. Starter Course: Use an Owens Corning® Starter product. Trim 61/2 inches off the rake of the starter course shingle and overhang the drip edge along the rake and eaves edge, 1/4 to 3/4 inch, and continue across the roof. Use 5 fasteners for each shingle, placed 2 to 3 inches up from eaves edge. See Fig. 5. If no drip edge is used, shingles must extend a minimum of 1/2 inch and no more than 1 inch from rake and eaves edge. Patrón de sujeción de las tejas Esquema de sujeción estándar: Los sujetadores deben colocarse en el área para clavado SureNail® Technology. Ver la Fig. 4. Esquema de sujeción de seis clavos: Para un esquema de sujeción de 6 clavos. Ver la Fig. 4A. Esquema de sujeción en mansarda o pendiente pronunciada: Coloque los sujetadores a 61/8 pulg. del borde inferior para asegurar ambas capas de la teja. Los sujetadores deben colocarse a 61/8 pulgadas por encima del extremo inferior de la teja, sin importar si es sobre los gránulos o el área de sujeción SureNail® Technology. Ver la Fig. 4B. REQUISITOS: En el caso de las pendientes que superen los 60 grados o 21 pulgadas por pie, utilice seis sujetadores y cuatro puntos de cemento asfáltico para techos por teja. Aplique inmediatamente un punto de cemento asfáltico para techos de 1 pulgada de diámetro debajo de cada lengüeta de las tejas. Coloque el cemento asfáltico para techos a 2 pulgadas del borde inferior de la lengüeta de la teja. Ver la Fig. 4B. En los casos en que se requiera, el cemento asfáltico para techos debe cumplir con la norma ASTM D4586 Tipo I o II (libre de asbesto). Nota: Tenga en cuenta que una cantidad excesiva de cemento asfáltico para techos puede deformar la teja. Hilera inicial: Utilice un producto de hilera inicial para techos de Owens Corning®. Recorte 61/2 pulgadas desde la cornisa del tímpano en la teja de la hilera inicial y nivele con el borde de goteo a lo largo de la cornisa y el borde del alero, entre 1/4 y 3/4 de pulg., y continúe a través del techo. Utilice 5 sujetadores para cada teja, colocados a una distancia de 2 a 3 pulgadas arriba del borde del alero. Ver la Fig. 5. Si no utiliza un borde de goteo, las tejas deberán extenderse un mínimo de 1/2 pulgada y un máximo de 1 pulgada desde la cornisa y el borde del alero. Install Instructions | TruDefinition® Duration® Shingles | April 2020 5 5 Shingle Application These shingles are applied with a 61/2 inch offset, with 55/8 inch exposure, over prepared roof deck, starting at the bottom of the roof and working across and up. This will blend shingles from one bundle into the next and minimize any normal shade variation. Application with offsets of 4 inches to 8 inches are also acceptable. Shingles and fasteners must be installed to ensure that end joints are no closer than 2 inches from the fastener in the shingle below and that the offsets are not less than 4 inches in all succeeding courses. First Course: Apply first course starting with the full shingle even with the starter course. See Fig. 5A. Fasten securely according to fastening instructions. See Fig. 4. Second Course: Remove 61/2 inches from the left end of this shingle and apply the remaining piece over and above the first course shingle and flush with edge of the first course with 55/8 inch exposure. See Fig. 5B. Fasten securely according to fastening instructions. See Fig. 4. Third Course: Remove 13 inches from the left end of this shingle and apply the remaining piece over and above the second course shingle flush with edge of the second course with 55/8 inch exposure. See Fig. 5C. Fasten securely according to fastening instructions. See Fig. 4. Fourth Course: Remove 191/2 inches from the left end of this shingle and apply the remaining piece over and above the third course shingle and flush with edge of the third course with 55/8 inch exposure. See Fig. 5D. Fasten securely according to fastening instructions. See Fig. 4. Fifth Course: Remove 26 inches from the left end of this shingle and apply the remaining piece over and above the fourth course shingle and flush with edge of the fourth course with 55/8 inch exposure. See Fig. 5E. Fasten securely according to fastening instructions. See Fig. 4. Sixth Course: Remove 321/2 inches from the left end of this shingle and apply the remaining piece over and above the fifth course shingle and flush with edge of the fifth course with 55/8 inch exposure. See Fig. 5F. Fasten securely according to fastening instructions. See Fig. 4. Succeeding Courses: For succeeding courses, repeat first through sixth course. See Fig. 5G. Instalación de las tejas Estas tejas se instalan con un desplazamiento de 61/2 pulgadas y un área expuesta de 55/8 pulgadas, sobre estructuras base de techos preparados, comenzando en la parte inferior del techo y realizando la aplicación de forma transversal y hacia arriba. De esta manera, las tejas de un paquete se mezclarán con las del siguiente y se reducirán al mínimo las variaciones normales de tonalidad. Las aplicaciones con desplazamientos de 4 u 8 pulgadas también son aceptables. Es necesario instalar las tejas y los sujetadores para garantizar que las uniones de los extremos no queden a menos de 2 pulgadas del sujetador de la teja que está debajo y que las superposiciones laterales no sean de menos de 4 pulgadas en las hileras siguientes. Primera hilera: Aplique la primera hilera comenzando con una teja completa, nivelada con la hilera inicial. Ver la Fig. 5A. Sujete firmemente de acuerdo con las instrucciones de sujeción. Ver la Fig. 4. Segunda hilera: Quite 61/2 pulgadas del extremo izquierdo de esta teja y aplique la pieza restante sobre y por encima de la teja de la primera hilera, nivelando con el borde de la primera hilera con un área expuesta de 55/8 pulgadas. Ver la Fig. 5B. Sujete firmemente de acuerdo con las instrucciones de sujeción. Ver la Fig. 4. Tercera hilera: Quite 13 pulgadas del extremo izquierdo de esta teja y aplique la pieza restante sobre y por encima de la teja de la segunda hilera, nivelando con el borde de la segunda hilera con un área expuesta de 55/8 pulgadas. Ver la Fig. 5C. Sujete firmemente de acuerdo con las instrucciones de sujeción. Ver la Fig. 4. Cuarta hilera: Quite 191/2 pulgadas del extremo izquierdo de esta teja y aplique la pieza restante sobre y por encima de la teja de la tercera hilera, nivelando con el borde de la tercera hilera con un área expuesta de 55/8 pulgadas. Ver la Fig. 5D. Sujete firmemente de acuerdo con las instrucciones de sujeción. Ver la Fig. 4. Quinta hilera: Quite 26 pulgadas del extremo izquierdo de esta teja y aplique la pieza restante sobre y por encima de la teja de la cuarta hilera, nivelando con el borde de la cuarta hilera con un área expuesta de 55/8 pulgadas. Ver la Fig. 5E. Sujete firmemente de acuerdo con las instrucciones de sujeción. Ver la Fig. 4. Sexta hilera: Quite 321/2 pulgadas del extremo izquierdo de esta teja y aplique la pieza restante sobre y por encima de la teja de la quinta hilera, nivelando con el borde de la quinta hilera con un área expuesta de 55/8 pulgadas. Ver la Fig. 5F. Sujete firmemente de acuerdo con las instrucciones de sujeción. Ver la Fig. 4. Hileras siguientes: Para las hileras siguientes, repita los pasos de la primera a la sexta hilera. Ver la Fig. 5G. Install Instructions | TruDefinition® Duration® Shingles | April 20206 6 Valley Construction Closed-Cut Valley: A closed-cut valley can be used as an alternative to woven and open valley and is applied as follows: • Lay a 36 inch wide valley liner of self-adhered membrane underlayment or equivalent. A 36 inch wide minimum 50 lb. smooth surface roll roofing can also be used as a valley liner. • Lay all shingles on one side of valley and across center-line of valley a minimum of 12 inches. • Fasten a minimum of 6 inches away from center-line on each side of valley. • Strike a chalk line 2 inches from the center-line of the unshingled side. • Apply shingles on the unshingled side up to the chalk line and trim, taking care not to cut the underlying shingles. • Clip upper corner of these shingles and install a 3 to 4 inch wide, continuous bead of roofing cement. • Press shingles firmly into cement. Both woven and metal valleys are acceptable alternatives. See Fig. 6. For California-Cut Valley, see technical bulletin at www.owenscorning.com. Construcción de limahoyas Limahoya cubierta: Es posible usar como alternativa una limahoya cubierta en lugar de una limahoya entramada o descubierta, y se aplica de la siguiente manera: • Coloque un revestimiento de limahoya de 36 pulgadas de ancho de impermeabilizante autoadhesivo o su equivalente. También es posible utilizar como revestimiento de limahoyas un rollo para techos de superficie lisa de 50 libras con un ancho mínimo de 36 pulgadas. • Coloque todas las tejas en un lado de la limahoya y atravesando la línea central de la limahoya un mínimo de 12 pulgadas. • Sujete a una distancia mínima de 6 pulgadas de la línea central a cada lado de la limahoya. • Con una tiza, trace una línea a 2 pulgadas de la línea central del lado que no tenga tejas. • Coloque las tejas sobre el lado que no tenga tejas hasta llegar a la línea de tiza y haga un recorte cuidando de no cortar las tejas que se encuentran por debajo. • Recorte la esquina superior de estas tejas e instale una tira continua de 3 a 4 pulgadas de ancho de cemento asfáltico Presione firmemente las tejas contra el cemento. • Es aceptable utilizar tanto limahoyas metálicas como tejidas. Ver la Fig. 6. Para una limahoya tipo California, consulte el Boletín técnico en www.owenscorning.com. Install Instructions | TruDefinition® Duration® Shingles | April 2020 7 7 8 Step Flashing Use 10 inches long and 2 inches wider than expected exposure corrosion-resistant metal where roof planes butt against vertical sidewalls or chimneys. Check local building codes. For additional flashing details, go to www.owenscorning.com. See Fig. 7. Hip & Ridge Application Use corresponding Owens Corning® Hip & Ridge Shingles to best complement shingle color. Follow specific application instructions as printed on the Hip & Ridge Shingle package. See Fig. 8. Aplicación para limatesa y cumbrera Use las tejas de limatesa y cumbrera Owens Corning® apropiadas para complementar el color de las tejas. Siga las instrucciones específicas de aplicación que se indican en el paquete de tejas de limatesa y cumbrera. Ver la Fig. 8. Tapajuntas escalonado Utilice metal resistente a la corrosión con una exposición de 10 pulgadas de longitud y de 2 pulgadas más de ancho que la exposición esperada en los puntos en los que los planos del techo se unen a las paredes laterales verticales o a chimeneas. Consulte los códigos de construcción locales. Para obtener más información sobre tapajuntas, visite www. owenscorning.com. Ver la Fig. 7. Install Instructions | TruDefinition® Duration® Shingles | April 20208 OWENS CORNING ROOFING AND ASPHALT, LLC ONE OWENS CORNING PARKWAY TOLEDO, OHIO, USA 43659 1-800-438-7465 (1-800-GET-PINK®) www.owenscorning.com Pub. No. 10014283-F. Printed in U.S.A. April 2020. THE PINK PANTHER ™ & © 1964 –2020 Metro-Goldwyn-Mayer Studios Inc. All Rights Reserved. The color PINK is a registered trademark of Owens Corning. © 2020 Owens Corning. All Rights Reserved.