Loading...
110 Poinsettia St ROW21-0043 Underground BoringOWNER:ADDRESS:CITY:STATE:ZIP: RUSSELL ERNEST L JR TRUST ET AL 460 OCEAN BLVD ATLANTIC BEACH FL 32233 COMPANY:ADDRESS:CITY:STATE:ZIP: SOUTHEAST UTILITIES 1 ENERGY PL PENSACOLA FL 32520 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 170640 0100 SALTAIR SEC 03 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 110 POINSETTIA ST RIGHT OF WAY SINGLE OR TWO FAMILY RIGHT OF WAY 54-ft. of underground boring for CATV $0.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL Notes: All runoff must remain on-site during construction. 2 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL Notes: Roll off container company must be on City approved list. Approved list can be obtained at the Building Department at City Hall. Roll off container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 5/12/2021 PERMIT NUMBER ROW21-0043 ISSUED: 5/12/2021 EXPIRES: 8/10/2021 RIGHT OF WAY PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT PW REVIEW BUILDING MOD OR ROW 001-0000-329-1004 0 $25.00 TOTAL: $25.00 3 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration, including sod, is required. 4 PUBLIC WORKS INFRASTRUCTURE INFORMATIONAL Notes: Any damage done to infrastructure must be repaired by Contractor. 5 PUBLIC WORKS AS-BUILT INFORMATIONAL Notes: Contractor must submit As-Built plans to City within 30 days after completion of project. 2 of 2Issued Date: 5/12/2021 PERMIT NUMBER ROW21-0043 ISSUED: 5/12/2021 EXPIRES: 8/10/2021 RIGHT OF WAY PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 DESCRIPTION ACCOUNT QTY PAID PermitTRAK $25.00 ROW21-0043 Address: 110 POINSETTIA ST APN: 170640 0100 $25.00 PUBLIC WORKS PLAN REVIEW $25.00 PW REVIEW BUILDING MOD OR ROW 001-0000-329-1004 0 $25.00 TOTAL FEES PAID BY RECEIPT: R15785 $25.00 Printed: Wednesday, May 12, 2021 3:05 PM Date Paid: Wednesday, May 12, 2021 Paid By: SOUTHEAST UTILITIES Pay Method: CREDIT CARD 454793062 1 of 1 Cashier: CG Cash Register Receipt City of Atlantic Beach Receipt Number R15785 I I I I I I ~+; CENTRALSQUARE RIGHT-OF -WAY/ EASE MENT PE RMIT APP LI CATION City of Atlan t i c Beach 800 Seminole Road, Atlanti c Beach, FL 32233 PERMITTEE RESPONSIBLE FOR NOTIFYING 811 AND OBTAINING UTILITY LOCATES **ALL INFORMATION H IGHLIGHTE D IN GRAY IS REQUI RED. Job Add ress 110 PolnseWa, Atlantic Beach FL 32233 Pe rmit Number ___________ _ Co ntractor Informat ion Compan y Southeast Utilities on be hal f of Comcast Address 1 Energy Pl Q ua lifying Age n t _G_i_na_G_a_v_ag;:.n_i ________ _ Ci t y Pen sacola State.EL_ Zip 3252 0 Phon e (BSOJ 363-3284 Em ail ggavagni@icd llc.com State Certificati o n /Re g ist r atio n # _______________________________ _ Architect __________________ Ph o n e __________ Em ai l __________ _ Engi neer Gina Gavagni Phon e (8 50) 36 3-3284 Email ggavagni@icdllc.com Worker s Co m p en sation l nsu r e r ~f?l~ ________________ OR Exem pt O Expiration Date ____ _ • Permittee d ecla r es that prior to filing t his appl icatio n they ha ve as certained t he location of all exist ing utilit ies, both aeria l and underground and the accu rate locat ions are shown o n t he sketches. • Whenever necessary for the construction, repai r, improvement, ma intenance, safe and e ffici ent operation, al teration or reloca t ion o f all, o r any po rtion of sa id street or ease ment as deter mined by the Public Works Director, any or all sai d po l es, w ires, pi pes, ca bles or other facil i t i es and app urtenances authori zed he r eu nder, shall be immediately removed from said street o r easem ent or r eset or r el ocate d hereon as required by t he Public Works Dir ector and at the expense of the Perm i t t ee unless reimbur seme nt is authorized. • All work shall m eet Ci ty of Atlantic Beach or Flori da De partment ofTr anspo rtation St andard s and be per form ed under the • • • • supervisio n of _TI_1m_S_al-'--ya_r_d __________________________ {Project Sup er in t enden t) with {Com pany Nam e) SEU Phon e (904 ) 531-6985 All mater ials an d eq uipment shall be subject t o i nspect ion by t he Public Works Di rector . All city p roperty shall be restored t o its o riginal cond ition as fa r as pract ica l, in keepi ng with City specifications and t he manner sa tisfactory t o t he Ci ty. A sketch o f plans co ve ring details of t his in stall ation, as w ell as a copy of a r ecent survey sh all be made a p art of t his permit. Calculations showing any increase in impervious area on owner's lot or in the City right-of-way are to be included with this application. The permittee shall commence actua l const ruct ion in good faith within ~ days. If the begi nning date i s m ore than 60 days from date of p ermit approval then permittee must r evi ew the permit with the Publ ic Works Direct or t o make sure no changes have o ccu rred in t h e area that would affect the perm itted const ru ction . It is understood and agr eed t hat t he rights and privi leges h erei n set out are granted on ly to t he ext ent of t he City's right, title and i nter es t in th e l and to be entered u pon and use d by t h e holder, an d t he holder will, at all t imes, assu me all risk of and indemnify, d ef en d and sa ve h arml ess the Ci ty of Atlantic Bea ch from and again st any and all loss, damage and cost of expe nses ari sing in any m anner of t he exercise o r attempted ex er cises by t he holder of the aforesaid righ ts and privil eges. The Public Wo r ks Direct or shall b e notified 24 ho rior to starti ng work and aga in immed iately upon completion . ____ ~;___...:..· __ ?U __ ·_o-.3_ :-<.!_ ';C._ u----1-.v'.....~-~.P-J<c=:..-,,¥------------Da t e_S_/_10_/_20_2_1 ___ _ STATE OF FLORIDA, COUNTY OF DUVAL AA Tbyhe foregMoing\. i~ntrumrt w~cr~~li~.e~i~ __ /_O __ d ay of __ ,_ V'-_~....,q.-----------~' 20 &l. \ (y...A..c,1 1 ~ VJJJ~ who personally appeared before me and (p rinted name of Permittee) voluntari ly for the purpose expressed in it. lid Personally Known [ ] Prod uced Id entification (Type) _________ _ H:\Appllcatlons & Forms\Word Documents\201801001 Right-of-Way Easement Penn it Applicatlon.docx Revision Date: 10/1/18 OKALOOSA COUNTY I DUVAL COUN1Y I VICINl1Y MAP: 110 POINSETTIA, ATLANTIC BEACH, FL 32233 POLK COUNTY HARDE:E COUNTY DESOTO COUNTY C HARLOTTE CO UNTY GLADES CO U NTY HENDRY CO UNTY COLLIER COUNTY COMCAST PERMIT REQUEST FOR LOCATION: 110 POINSETTIA, ATLANTIC BEACH, FL 32233 THESE PLANS WERE PREPARED UNDER THE RESPONSIBLE CHARGE OF COMCAST AND ARE EXEMPT FROM THE SIGNING AND SEALING REQUIREMENTS PRESCRIBED IN SECTION 471 OF FLORIDA STATUTES SAINT LUC IE COUNTY MARTIN COUNTY PALM BEACH COUNTY BROWARD COUNTY NO EXPECTED CONFLICTS WITH 0TH ER UTILITIES LOCATION: 110 POINSETTIA, ATLANTIC BEACH, FL 32233 TOTAL LENGTH OF JOB: 54' UG DESCRIPTION: CATV DIRECTIONAL BORE DRAWN BY: ACE DATE: 5/7/2021 SCALE: NTS SHEET 1 OF 4 NOTES: ALL PROPOSED UNDERGROUND CATV WILL BE BURIED A MINIMUM OF 36" DEEP EXCEPT ROAD BORES 60" DEEP AND DRIVEWAY BORES AT 60" DEEP. ALL PROPOSED UNDERGROUND CATV ROAD BORES WILL USE CITY APPROVED DIRECTIONAL BORE MACHINE, AS WELL AS COUNTY APPROVED CONDUIT. ALL PROPOSED CATV ROAD BORES WILL EXTEND A MINIMUM OF 7' BEYOND THE EDGE OF PAVEMENT. ALL PROPOSED CATV DRIVEWAY BORES WILL EXTEND A MINIMUM OF 6' BEYOND THE EDGE OF PAVEMENT. ALL PROPOSED BORES WILL BE IN A ( 4'X4'X4') PIT AND WILL USE (2)2" HOPE CONDUIT AT 48" DEPTH USING A 5 1 / 4" DRILL HEAD. ALL PROPOSED AERIAL WILL BE . 700" DIAMETER AND WILL BE LASHED TO .250" STEEL STRAND CABLE USING .125" STANDARD GALVANIZED LASHING WIRE. ALL PROPOSED AERIAL CATV CROSSING ROADWAYS WILL HAVE MINIMUM MID-SPAN HEIGHT OF 18'-0" ALL PROPOSED AERIAL CATV CROSSING DRIVEWAYS WILL HAVE MINIMUM MID-SPAN HEIGHT OF 16'-0" LOCATES WILL BE REQUIRED IN ALL PROPOSED UNDERGROUND AREAS AT LEAST 48 HRS PRIOR TO CONSTRUCTION. NOTIFICATIONS TO ALL UTILITIES INVOLVED WILL BE MADE PRIOR TO CONSTRUCTION. ALL DISTRIBUTED AREA WITHIN THE RIGHT OF WAY WILL BE RESTORED TO ORIGINAL OR BETTER CONDITION BY GRADING AND RE-SODDING. SOD ALL AREAS DISTURBED BY CONSTRUCTION WITH BERMUDA SOD. "ALL CRACKED SIDEWALK IS TO BE REPLACED FROM JOINT TO JOINT WITHIN 7 DAYS OF WORK COMPLETION." WORK OPERATIONS ARE TO BE MINDFUL NOT TO DAMAGE THE PAVER SIDEWALK WHEN POSITIONING EQUIPMENT. ANY DAMAGE INCLUDING TRACK MARKS WILL BE REPAIRED OR REPLACED BY THE CONTRACTOR. CONSTRUCTION NOTES: IN ORDER TO REDUCE THE DISRUPTION AND COST OF UTILITY DAMAGES OCCURRING IN THE RIGHT -OF-WAY AND EASEMENTS. THE PERMITTEE SHALL PREVENT DAMAGES TO EXISTING UTILITIES CAUSED BY THE WORK THROUGH FIELD VERIFICATION OF THE LOCATION OF THE EXISTING UTILITIES IN CASE OF OPEN EXCAVATION. VERIFICATION MAY BE PERFORMED DURING THE PERMITTEES WORK. IN THE CASE OF DIRECTIONAL DRILLING, VERIFICATION SHALL TAKE PLACE PRIOR TO MOBILIZATION OF THE DRILLING EQUIPMENT. THE PERMITTEE SHALL VERIFY THE LOCATION OF THE EXISTING UTILITIES AS NEEDED TO AVOID CONTACT WITH DETECTION EQUIPMENT OR OTHER ACCEPTABLE MEANS, SUCH METHODS MAY INCLUDE BUT SHALL NOT BE LIMITED TO-"SOFT DIG"-EQUIPMENT AND GROUND PENETRATION RADAR (GPR). THE EXCAVATOR SHALL BE HELD LIABLE FOR DAMAGES CAUSED TO CITY'S/COUNTIES/STATE INFRASTRURE AND THE EXISTING FACILITIES OF THE OTHER UTILITY COMPANIES NO REAMER USED THE FOLLOWING STANDARD PLANS ARE IN ACCORDANCE WITH THE FLORIDA DEPARTMENT OF TRANSPORTATION 102-602 INDEX AND APPLY TO: 11 0 POINSETTIA, ATLANTIC BEACH, FL 32233 COMCAST PERMIT REQUEST FOR LOCATION: 110 POINSETTIA, ATLANTIC BEACH, FL 32233 I NO BACKREAMER USED I INO EXPECTED CONFLICTS I WITH OTHER UTILITIES LOCATION: 110 POINSETTIA, ATLANTIC BEACH, FL 32233 TOTAL LENGTH OF JOB: 54' UG DESCRIPTION: CATV DIRECTIONAL BORE DRAWN BY: ACE DATE: 5/7/2021 SCALE: NTS SHEET 2 OF 4 0+54 END BORE HERE CATV PED PROPOSED BORE PLACEMENT FOR 54' ALONG POINSETTIA ST AT MIN DEPTH OF 36" USING 2" 13.5 SOR ROLL PIPE WITH COAXIAL CABLE INSIDE o+o BEGIN BORE HERE CATV PED "\ (J (Q ,..__ I ,..__ I 3: "-a::: 13' 36" MIN-n 48" MIN- () () () i::: w I-a::: _J O w <CWWI-: Of-_J<( w 3: I I POINSETTIA ST TYP ALLOCATION 3: "- c., ~a.. oo w N 11' n' _'i' I::• -.J c., ~ 0 :,o' 20' I CJL NO BACKREAMER USED NO EXPECTED CONFLICTS WITH OTHER UTILITIES a::: c., a..~ Oo w N 13 LOCATION: 11 0 POINSETTIA, ATLANTIC BEACH, FL 32233 TOTAL LENGTH OF JOB: 54 UG DESCRIPTION: CATV DIRECTIONAL BORE DRAWN BY: ACE DATE: 5/7/2021 SCALE: NTS SHEET 3 OF 4 END ROAD WORK c[] ¢= A ¢= c[] ROAD WORK AHEAD -----------------------------------------+----------------------------- =;> I =;> [Ji [Ji [Ji ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ [Ji I ■ A B * I ROAD / <&, WORK AHEAD SPEEDING FINES DOUBLED WHEN WORKERS PRESENT Device Spacing-Taper Device Spacing-Tangent See Table I See Table I Table I 500' END ROA D WORK Device Spacinq Max. Distance Between Devices (ft.) Speed Cones or Type I or Typ e II Barricades or Vertical DISTANCE BETWEEN SIGNS (mph) Tubular Markers Panels or Drums Speed 40 mph or fess 45 mph 50 mph or greater 'Midway between signs. SYMBOLS ~ Work Area ■ Channelizing Device (See Index 102-600) [Ji Work Zone Sign =;> Lane Identification+ Direction of Traffic <: DESCRIPTION: a Spacing (ft.) Taper Tangent Taper A B 25 25 50 25 200 350 500 200 30 to 45 25 50 30 350 500 50 to 70 25 50 50 GENERAL NOTES 1. When four or mor e work vehicles enter the through traffic lanes in a one hour period or fess (excluding establishing and terminating the work area}, the advanced FLAGGER sign shall be substituted for the WORKERS sign . For location of flaggers and FLAGGER signs, see Index 102-603. 2. SHOULDER WORK sign may be used as an alternate to the WORKER symbol sign only on the side where the shoulder work is being performed . 3. When a side road intersects the highway w ithin the TT C zone, additional TT C devices shall be placed in accordance with other applicable TC Z Indexes. 4. For general TCZ requirements and additional information, refer to Index 102-600. FY 2020-21 T angent 50 50 100 DURATION NOTES 1. Signs and channelizing devices may be omitted if all of the following conditions are met : a. Work operations are 60 minutes or fess. b. Vehicles in the w ork area have high-intensity, rotating, flashing, osc i llating, or strobe fights operating. Table II Taper Length -Shoulder ½L (ft) Speed (mph) 8' 10' Notes 12 ' Shfdr. Shfdr. Shfdr. 25 28 35 42 30 40 50 60 L= WSZ 35 55 68 82 60 40 72 90 107 45 120 150 180 50 133 167 200 55 147 183 220 60 160 200 240 L=WS 65 173 217 260 70 187 233 280 8' minimum shoulder width ½L = Length of shoulder taper in feet W = Width of total shoulder in feet (combined paved and unpaved width) S = Posted speed limit (mph) CONDITIONS WHERE ANY VEHICLE, EQUIPMENT, WORKERS OR THEIR ACTIVITIES ENCROACH THE AREA CLOSER THAN 15 ' BUT NOT CLOSER THAN 2' TO THE EDGE OF TRAVEL WAY. INDEX LAST REVISION 11/01/17 vi ;: ST AN OARD PLANS TWO -LANE , TWO -WAY, WORK ON SHOULDER 102-602 IJJ ex: SHEET 4 OF 4