601 Levy Rd ROW21-0044 AT&T buried cable permitOWNER:ADDRESS:CITY:STATE:ZIP:
COMPANY:ADDRESS:CITY:STATE:ZIP:
AT&T dba Bellsouth
Telecommunications DBA ATT ATLANTIC BEACH FL 32233
TYPE OF
CONSTRUCTION:
REAL ESTATE
NUMBER:ZONING:BUILDING USE
GROUP:SUBDIVISION:
JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK:
601 LEVY ROAD RIGHT OF WAY COMMERCIAL
RIGHT OF WAY
AT&T BURIED FIBER CABLE
AND FLEXIBLE CONDUIT $0.00
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
1 PUBLIC WORKS EROSION CONTROL INSTALLATION INFORMATIONAL
Notes:
Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line (904-247-
5814) to request an Erosion and Sediment Control Inspection prior to start of construction.
2 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL
Notes:
All runoff must remain on-site during construction.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN
YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT
MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU
INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT.
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
1 of 2Issued Date: 5/18/2021
PERMIT NUMBER
ROW21-0044
ISSUED: 5/18/2021
EXPIRES: 8/16/2021
RIGHT OF WAY PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
TOTAL:
3 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL
Notes:
Roll off container company must be on City approved list. Approved list can be obtained at the Building Department at City Hall. Roll off container
cannot be placed on City right-of-way.
4 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL
Notes:
Full right-of-way restoration, including sod, is required.
5 PUBLIC WORKS INFRASTRUCTURE INFORMATIONAL
Notes:
Any damage done to infrastructure must be repaired by Contractor.
6 PUBLIC WORKS AS-BUILT INFORMATIONAL
Notes:
Contractor must submit As-Built plans to City within 30 days after completion of project.
7 PUBLIC WORKS OTHER PUBLIC WORKS CONDITION INFORMATIONAL
Notes:
All right-of-ways and all roads must be kept clean and free of sand, dirt, mud, and debris at all times during construction at multiple locations within the
City.
8 PUBLIC UTILITIES UNDERGROUND WATER SEWER UTILITIES INFORMATIONAL
Notes:
Avoid damage to underground water and sewer utilities. Verify vertical and horizontal location of utilities. Hand dig if necessary. If field coordination is
needed, call 247-5878.
2 of 2Issued Date: 5/18/2021
PERMIT NUMBER
ROW21-0044
ISSUED: 5/18/2021
EXPIRES: 8/16/2021
RIGHT OF WAY PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
ROW21-0044
N/A
PRIOR TO BEGINNING CONSTRUCTION.
CONTRACTOR TO PROVIDE A NOTICE OF COMMENCEMENT TO THE PERMIT AGENCY ENGINEERING DEPARTMENT 48 HOURS 10)
INSPECTOR IS PRESENT AT THE JOB SITE AND AGREES THAT THE PROPER PREPARATIONS HAVE BEEN MADE.
UTILITY ACCOMMODATION MANUAL. PERMITEE SHALL NOT BEGIN A DIRECTIONAL BORE ACROSS A STATE ROAD UNTIL A FDOT
DESIGN STANDARDS, THE LATEST EDITION OF THE SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION AND THE 2018
ALL WORK PERFORMED WITHIN THE RIGHT-OF-WAY SHALL BE IN ACCORDANCE WITH THE LATEST EDITIONS OF THE FDOT 9)
OTHERWISE NOTED).
MAINTAIN 18" VERTICAL CLEARANCE, 6' HORIZONTAL CLEARANCE BETWEEN EXISTING UTILITIES AND 24" COVER (UNLESS 8)
CALL ONE CALL FLORIDA AT 811 TO REQUEST A LOCATE OF ANY UNDERGROUND FACILITIES AT YOUR EXCAVATION SITE.7)
SOFT DIGGING, VACUUM EXCAVATION ETC. BE USED IN THE 36" TOLERANCE ZONE TO EXPOSE UNDERGROUND FACILITIES.
ALL TRENCHES WILL BE OPENED AND MAINTAINED FOLLOWING STANDARDS. IT IS RECOMMENDED THAT AND DIGGING, SOFT, 6)
RESTORE ALL EXCAVATIONS TO ORIGINAL OR BETTER.5)
CALL FOR INSPECTIONS.4)
CONTRACTORS FOR VERIFICATION OF EXACT LOCATION PRIOR TO WORK OPERATIONS.
UTILITY LOCATIONS (TELEPHONE AND NON-TELEPHONE) ARE TO BEST INFORMATION AND APPROXIMATE ONLY. SEE OWNERS & 3)
RESTORATION PER FDOT STANDARDS.2)
SIDEWALK TO BE REMOVED AND REPLACED AS NEEDED FOR BORE AND CORE.1)
CONSTRUCTION NOTES:
MAINTENANCE OF TRAFFIC PLANS INCLUDED WITH DRAWINGS
S
T
O
C
K
S
S
T
M
A
I
N
S
T
W 14TH ST
J
A
S
M
I
N
E
S
T
B
E
G
O
N
I
A
S
T
L
A
U
R
E
L
W
A
Y
M
A
R
S
H
V
I
E
W
C
T
L
I
L
Y
S
T
G
L
A
D
I
O
L
A
S
T
W PLAZA ST
C
A
R
N
A
T
I
O
N
S
T
T
U
L
I
P
S
T
W PLAZA ST
LEVY
RD
MEMORIAL DR
KESTNER RD
PARADISE CT
VICINITY MAP
C
A
M
E
L
I
A
S
T
STEWART ST
CAUTION
Volts to Ground
301V-15kV
TWO FULL BUS. DAYS BEFORE YOU DIG
CALL BEFORE YOU DIG
1-800-432-4770
DIAL 811 or
FLORIDA
www.call811.com
UTILITIES IS WITHHELD.
CERTIFICATION TO THE LOCATION OF ALL UNDERGROUND
APPROXIMATE AND POSSIBLY INCOMPLETE. THEREFORE
THE LOCATION OF UTILITIES SHOWN ON THIS PLAT ARE
UTILITY COMPANIES PRIOR TO ANY CONSTRUCTION AS
IT IS THE CONTRACTORS RESPONSIBILITY TO CONTACT
Description
BST POLE
POWER POLE
ANCHOR & GUY
PUSH BRACE
Proposed Existing
PIPE/CONDUIT
ENCLOSURE
MANHOLE
SYMBOL LEGEND
CUT PAVEMENT
SPLICING PIT
BORE
N/A
N/A
N/A
CABLE MARKER
N/A200'@ÒÊÌÔÓ TRENCH LEN@DEPTH
AERIAL CABLE
AERIAL SVC WIRE
BUR JOINT-TRENCH
BURIED CABLE
BURIED SVC WIRE
JOINT-TRENCH SVC
ENCLOSURE
TOTAL ROADWAY BORES: 16
TOTAL HANDHOLES: 40
TOTAL CONDUIT: 1410'
TOTAL BURIED CABLE: 4376'
TOTAL AERIAL CABLE: 6618'
NEW HANDHOLES WITHIN THE CITY'S ROW.
DORECTIONAL BORE NEW FIBER CABLE AND CONDUIT. PLACE
AT&T PROPOSES TO PLACE/ LASH NEW AERIAL FIBER CABLE.
SCOPE OF WORK:
Dwg.of 451
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
#601, 602, 660
FLDOT M.O.T. INDEX NO:
WORKERS WILL UTILIZE
MAINTENANCE OF TRAFFIC
RANGE: 30E
TOWNSHIP: 23S
SECTION: 18
ROW21-0044
17"
3
0"
36"
1
5"
36"
10"
Dwg.of 452
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
CONSTRUCTION NOTE:
FOR LOCATES
PRIOR TO START OF CONSTRUCTION
SUNSHINE STATE ONE-CALL ( 811 )
THE CONTRACTOR MUST CONTACT
Handhole
Handhole
TYPICAL HAND HOLE DIMENSIONS
-Structure Is To Be Installed Flush-
With Existing Ground Line
Handhole
Handhole
TYPICAL HAND HOLE DIMENSIONS
-Structure Is To Be Installed Flush-
With Existing Ground Line
LEVY
RD
M
A
I
N
S
T
B
K
M
A
-
5
0
B
K
M
A
-
5
0
20'
14'
14'13'
6
M
S
T
R
A
N
D
P1
AT&T - 19' 7"HOA
MGNV = N
S
R
-
5
B
Q
2
M
T
-
0
2
4 A
F
M
W
-
2
0
0
CAUTION
Volts to Ground
HOA
MGNV = Y
AT&T - 19' 4"
AT&T - 20' 1"
HOA
P2
2
5
0
'
6
M
S
T
R
A
N
D
9
5
'
0
+
0
0
0
+
6
6
DEPTH
TO BURY
POLE 3'
20' UP
55-1
30-5
CABINET
FIBER PFP
EXISTING
1
-10M
5
'
/19
'
7"
MR1
-1
P=DE
1
-10M
5
'
/19
'
1"
48'
LEVY RD
CABLE PLACEMENT
X
43
'
E
O
P
E
O
P
min.
Aerial Clearance Detail
-VARIES -
18'
B B
REQUIRED
AS
Bore Detail - NO Drainage Ditch Involved
min.
36"
20'
50'
13'
17'
MAIN ST
CABLE PLACEMENT
JEA
JEA
See Dwg #4
See Dwg #38
EOP
EOP
E
O
P
E
O
P
EOP
EOP
E
O
P
E
O
P
R
/
W
R
/W
R
/W
R
/
WR
/
W
R
/W
C/L
R/W
R/W
EOP
EOP
EXISTING AERIAL CABLES
PROPOSED AERIAL CABLES LASHED TO
R
/W
R
/
W
1
-10M
5
'
/18
'
7"
HANDHOLE
EXISTING
AND LASHED TO EXISTING AERIAL CABLES
@ 36" MIN DEPTH BY DIRECTIONAL BORE
PROPOSED BURIED & AERIAL CABLE BURIED
C/L
R/W
R/W
EOP
EOP
MAIN ST
CROSS SECTION
C
/
L
E
O
P
E
O
P
R
/
W
R
/
W
LEVY RD
CROSS SECTION
C
/
L
E
O
P
E
O
P
R
/
W
R
/
W
Dwg.of 453
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
CULVERT
C
U
L
V
E
R
T
1
3
'
10
'
GROUND
ALL WIDTHS VARY
HYDRANT
F
IRE
-
ALL WIDTHS VARY
50'
25'
20'
25'
36"
1'
13'17'
48'
24'
20'
24'
36"
1'
14'14'
301V-15kV
10
11
11
28
28
10
BURIED CABLE
PROPOSED SEWER
WATER
BURIED CABLE
PROPOSED
WATER
W 14TH ST
M
A
I
N
S
T
1398
1396
1399
1395
A
F
M
W
-
9
0
0
B
K
M
A
-
5
0
B
K
T
A
-
5
0
B
K
M
S
-
2
0
0
206'
1 5
1 '
1 2
0
'
BKMA-400
6
M
S
T
R
A
N
D
6
M
S
T
R
A
N
D
6M STRAND
MGNV = Y
MGNV = Y
AT&T - 20' 1"
AT&T - 20' 8"
AT&T - 21' 6"
P12
P13
HOA
HOA
HOA
CAUTION
Volts to Ground
589
50-2
55-1
E
O
P
E
O
P
min.
Aerial Clearance Detail
-VARIES -
18'
JEA
See Dwg #3
S
e
e
D
w
g
#
5
JEA
E
O
P
E
O
P
EOP
EOP EOP
EOP
E
O
P
E
O
P
R
/
W
R
/
W
R/W
R/W
R
/
WR
/
W
R/W
R/W
See Dwg #29
EXISTING AERIAL CABLES
PROPOSED AERIAL CABLES LASHED TO
M
R
3
-
5
/
8
P
=
F
D
E
1
-
6
M
1
5
'
/
2
0
'
Dwg.of 454
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
301V-15kV
12
12
11
11
25
25
720 1397
0 600
1398
C
A
M
E
L
I
A
S
T
W 14TH ST
BKMA-400
B
K
M
S
-
5
0
B
K
M
S
-
5
0
BKMA-400
98'
1 6
8
'
1 0
0
'
6M STRAND
6
M
S
T
R
A
N
D
6
M
S
T
R
A
N
D
AT&T - 19'
P33
1416
MGNV = Y
MGNV = Y
AT&T - 17' 10"
AT&T - 18' 3"
P34
HOA
HOA
HOA
255'
50-2
45-3
E
O
P
E
O
P
min.
Aerial Clearance Detail
-VARIES -
18'
JEA
S
e
e
D
w
g
#
4
S
e
e
D
w
g
#
6
See Dwg #27
See Dwg #28
EOP
EOP EOP
EOP
E
O
P
E
O
P
E
O
P
E
O
P
R/W
R/W
R
/
W
R
/
W
R/W
R/W
R
/
W
R
/
W
JEA
EXISTING AERIAL CABLES
PROPOSED AERIAL CABLES LASHED TO
Dwg.of 455
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE12
12
14
14
13
13
20'
12'
50'14'
16'
JASMINE ST
CABLE PLACEMENT
CAUTION
Volts to Ground
720750
0 1416
820
J
A
S
M
I
N
E
S
T
W 14TH ST
BKMA-400BKMA-400
B
K
M
S
-
2
5
A
M
F
W
-
2
5
0+00
1 0
2
'
6M STRAND
6
M
S
T
R
A
N
D
1416
P39
HOA
HOA
AT&T - 18' 9"
AT&T - 19' 9"
AT&T - 19' 7"
GUY'D
UNDER
DEPTH
TO BURY
POLE 3'
20' UP
247'
45-3
1
1
'
X
1
8
'
9
"
1
-
6
M
M
R
3
5
/
8
P
=
D
E
X
E
O
P
E
O
P
min.
Aerial Clearance Detail
-VARIES -
18'
C/L
R/W
R/W
EOP
EOP
EXISTING AERIAL CABLES
PROPOSED AERIAL CABLES LASHED TO
BY DIRECTIONAL BORE
PLACED @ 36" MIN DEPTH
PROPOSED BURIED FIBER CABLE
JASMINE ST
CROSS SECTION
C
/
L
E
O
P
E
O
P
R
/
W
R
/
W
JEA
See Dwg #24
See Dwg #26
S
e
e
D
w
g
#
5
S
e
e
D
w
g
#
7
E
O
P
E
O
P
EOP
EOP
EOP
EOP
E
O
P
E
O
P
R/W
R/W
R
/
W
R
/
W
R/W
R/W
R
/
W
R
/
W
1
-
1
0
M
1
1
'
X
1
8
'
6
"
Dwg.of 456
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
ALL WIDTHS VARY
50'
25'
20'
25'
36"
2'
14'16'
301V-15kV
12
16
17
BURIED CABLE
PROPOSED
WATER
SEWER
12
16
17
820850
0 1416
1390
W 14TH ST
B
K
M
S
-
2
5
B
K
M
S
-
1
0
0
B
K
M
G
-
5
0
9
7
'
1
+
0
4
50'
5'
BEGONIA ST
CABLE PLACEMENT
2
+
4
7
0
BKMA-400
6M STRAND
MGNV = Y
AT&T - 18' 1"
AT&T - 19' 1"
AT&T - 19' 6"
P43
HOA
HOA
CAUTION
Volts to Ground
0+00
6
M
S
T
R
A
N
D
DEPTH
TO BURY
POLE 3'
20' UP
45-3
1
-
6
M
1
4
'
X
1
9
'
6
"
M
R
1
-
1
P
=
D
E
1
4
'
/
1
8
'
1
"
1
-
6
M
12'X19'1"
1-10M
MR1-1
P=DE
GUY'D
UNDER
E
O
P
E
O
P
min.
Aerial Clearance Detail
-VARIES -
18'
B
E
G
O
N
I
A
S
T
20'
20'
GUY'D
UNDER
10'
JEA
S
e
e
D
w
g
#
6
See Dwg #8
See Dwg #16
EOP
EOP
R/W
R/W
R
/
W
R/W
R/W
R
/
W
C/L
R/W
R/W
EOP
EOP
EXISTING AERIAL CABLES
PROPOSED AERIAL CABLES LASHED TO
1
-
1
0
M
1
4
'
X
1
9
'
6
"
12'X19'1"
1-6M
12'X18'7"
1-6M
BY DIRECTIONAL BORE
PLACED @ 36" MIN DEPTH
PROPOSED BURIED FIBER CABLE
BEGONIA ST
CROSS SECTION
C
/
L
E
O
P
E
O
P
R
/
W
R
/
W
E
O
P
E
O
P
E
O
P
E
O
P
R
/
W
R
/
W
Dwg.of 457
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
ALL WIDTHS VARY
50'
25'
20'
25'
36"
5'
10'20'
301V-15kV
12
12
18
18
19
19
BURIED CABLE
PROPOSED
WATERSEWER
1324 1390
BEGONIA ST
BKMG-50
1265 1275
50'
5'
BEGONIA ST
CABLE PLACEMENT
CAUTION
Volts to Ground
D
/
W
D
/
W
D
/
W
VACANT
2
+
4
5
20'
20'
10'
B B
min.min.
VARIES
E
O
P
E
O
P
BEGONIA ST
Bore Detail - NO Drainage Ditch Involved
DRIVEWAY
36"min.48"
min.
36"min.
6' 6'
S
e
e
D
w
g
#
7
S
e
e
D
w
g
#
9
EOP
EOP
R/W
R/W
C/L
R/W
R/W
EOP
EOP
BY DIRECTIONAL BORE
PLACED @ 36" MIN DEPTH
PROPOSED BURIED FIBER CABLE
BEGONIA ST
CROSS SECTION
C
/
L
E
O
P
E
O
P
R
/
W
R
/
W
ROW
HANDHOLE 5' FROM
PROPOSED 10" X 15"
Dwg.of 458
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
ALL WIDTHS VARY
5'
50'
25'
20'
25'
36"
5'
10'20'
301V-15kV
18
18
BURIED CABLE
PROPOSED
WATERSEWER
1203
1225
1170
B
E
G
O
N
I
A
S
T
W PLAZA ST
B
K
M
G
-
5
0
50'
5'
BEGONIA ST
CABLE PLACEMENT
3+50
ANMW-100
0+27
0+42
1245
1255
15'
25'1'8'
9'
W PLAZA
CABLE PLACEMENT
CAUTION
Volts to Ground
D
/
W
0
1215
20'
20'
B B
min.min.
VARIES
E
O
P
E
O
P
BEGONIA ST
Bore Detail - NO Drainage Ditch Involved
36"min.48"
min.
36"min.
6' 6'
B B
min.min.
VARIES
E
O
P
E
O
P
BEGONIA ST
Bore Detail - NO Drainage Ditch Involved
DRIVEWAY
36"min.48"
min.
36"min.
6' 6'
10'
R
/
W
See Dwg #8
S
e
e
D
w
g
#
1
0
EOP
EOP
E
O
P
E
O
P
E
O
P
E
O
P
R/W
R/W
R
/
W
C/L
R/W
R/W
EOP
EOP
C/L
R/W
R/W
EOP
EOP
CONDUIT
PROPOSED 4" X 19'
BY DIRECTIONAL BORE
PLACED @ 36" MIN DEPTH
PROPOSED BURIED FIBER CABLE
BEGONIA ST
CROSS SECTION
C
/
L
E
O
P
E
O
P
R
/
W
R
/
W
W PLAZA ST
CROSS SECTION
C
/
L
E
O
P
E
O
P
R
/
W
R
/
W
ROW
HANDHOLE 1' FROM
PROPOSED 10" X 15"
Dwg.of 459
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
ALL WIDTHS VARYALL WIDTHS VARY
50'
25'
20'
25'
36"
5'
10'20'
25'
13'
15'
12'
36"
1'
9'1'
301V-15kV
18
18
BURIED CABLE
PROPOSED
WATERSEWER
BURIED CABLE
PROPOSED
1251
1200
1280
0
1170
T
U
L
I
P
S
T
A
N
M
W
-
1
0
0
1250
15'
25'
15'
50'
11'
24'
1'8'
9'
W PLAZA
CABLE PLACEMENT
W PLAZA
8'
TULIP ST
CABLE PLACEMENT
6+42
0
+
0
0
0+00
TURN
5+84
D/W
D/W
D/W
1350
0
+
3
2
1+70
VACANT
B B
min.min.
15'
E
O
P
E
O
P
TULIP ST
Bore Detail - NO Drainage Ditch Involved
36"min.48"
min.
36"min.
6' 6'
S
e
e
D
w
g
#
9
See Dwg #11
EOP
EOP
R
/
W
R
/
W
R/W
R/W
R
/
W
R
/
W
C/L
R/W
R/W
EOP
EOP
C/L
R/W
R/W
EOP
EOP
E
O
P
E
O
P
PLACED BY DIRECTIONAL BORE
PROPOSES 1.5" CONDUITS
BY DIRECTIONAL BORE
PLACED @ 36" MIN DEPTH
PROPOSED BURIED FIBER CABLE
TULIP ST
CROSS SECTION
C
/
L
E
O
P
E
O
P
R
/
W
R
/
W
W PLAZA ST
CROSS SECTION
C
/
L
E
O
P
E
O
P
R
/
W
R
/
W
ROW
HANDHOLE 2' FROM
PROPOSED 10" X 15"
ROW
HANDHOLE 2' FROM
PROPOSED 10" X 15"
ROW
HANDHOLE 16' FROM
PROPOSED 10" X 15"
Dwg.of 4510
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
ALL WIDTHS VARY
ALL WIDTHS VARY
50'
25'
15'
25'
36"
16'
24'11'
25'
13'
15'
12'
36"
1'
9'1'
18
18
76
76
77
77
BURIED CABLE
PROPOSED
BURIED CABLE
PROPOSED
109510401080
T
U
L
I
P
S
T
C
A
R
N
A
T
I
O
N
S
T
W PLAZA ST
1090
MGNV = Y
215'32'
A
N
M
W
-
1
0
0
15'
50'
11'
24'
8'
TULIP ST
CABLE PLACEMENT
6M STRAND
MGNV = Y
AT&T - 18' 6"AT&T - 19' 2"
P48P49
HOA HOA
CAUTION
Volts to Ground
1200
9+19
AT&T - 20' 6"
HOA - AT&T - 20' 6"
PROPOSED
MGNV = Y
P47
HOA
DEPTH
TO BURY
POLE 3'
21' UP
253'
45-345-3
35-4
GUY'D
UNDER
E
O
P
E
O
P
min.
Aerial Clearance Detail
-VARIES -
18'
See Dwg #10
See Dwg #12
S
e
e
D
w
g
#
1
3
JEA
E
O
P
E
O
P
EOP
EOP
E
O
P
E
O
P
R
/
W
R
/
W
R/W
R/W R/W
R/W
R
/
W
R
/
W
R
/
W
C/L
R/W
R/W
EOP
EOP
R
/
W
JEA
R
/
W
R
/
W
EXISTING AERIAL CABLES
PROPOSED AERIAL CABLE LASHED TO
JEA
1/16M
12'X19'11"MR1-1
P=DE
1/16M
12'X20'5"
1/10M
MR1-1
P=DE
5'X20'5"
BY DIRECTIONAL BORE
PLACED @ 36" MIN DEPTH
PROPOSED BURIED FIBER CABLE
TULIP ST
CROSS SECTION
C
/
L
E
O
P
E
O
P
R
/
W
R
/
W
Dwg.of 4511
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
ALL WIDTHS VARY
50'
25'
15'
25'
36"
16'
24'11'
301V-15kV
18
18
20
20
BURIED CABLE
PROPOSED
min.
B B
FOR DETAILS
SEE DWG
Directional Bore Detail - No Drainage Ditch Involved
PARALLEL INSTALLATION - TULIP ST
36"min.36"36"
1090
1080
1082
1251 1011
C
A
R
N
A
T
I
O
N
S
T
CAUTION
Volts to Ground
1 4
6
'
FOR REFERENCE
45-3
See Dwg #11
E
O
P
E
O
P
R
/
W
R
/
W
Dwg.of 4512
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
301V-15kV
10901280
1209
1201
0
1251
0
G
L
A
D
I
O
L
A
S
T
110'
MGNV = Y
1 2
5
'
1 0
5
'
2
0
'
W PLAZA
6M STRAND
NEW 6M STRAND
N
E
W
6
M
S
T
R
A
N
D
0
CATV - 19' 4"
PWR - 22' 5"
MGNV = Y
AT&T - 19' 7"
LOTS
3 FUTURE
P50P51
HOA
HOA - AT&T - 19' NORTH
PROPOSED
HOA - AT&T - 18' 4"
PROPOSED
CAUTION
Volts to Ground
MGNV = Y
CATV - 19' 1"
PWR - 22' 10"
HOA - AT&T - 18'
PROPOSED
P54
45-3 45-3
45-3
35-4
E
O
P
E
O
P
min.
Aerial Clearance Detail
-VARIES -
18'
S
e
e
D
w
g
#
1
1
See Dwg #14
S
e
e
D
w
g
#
1
5
JEAJEA
E
O
P
E
O
P
EOP
EOP
EOP
EOP
R/W
R/W
R/W
R/W
R
/
W
R
/
W
R
/
W
R
/
W
EXISTING AERIAL CABLES AND NEW STRAND
PROPOSED AERIAL CABLES LASHED TO
JEA
O
H
G
1
-
6
M
1
/
1
6
M
1
1
'
/
1
9
'
7
"
M
R
2
3
/
4
P
=
D
E
2
0
'
Dwg.of 4513
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
301V-15kV
20
20
21
21
1251
1304
1301
0
0
0
9
9
'
MGNV = Y
MGNV = Y
CATV - 24' 4"
PWR - 27' 2"
HOA - AT&T - 23' 4"
PROPOSED
CATV - 19' 11"
PWR - 23'
HOA - AT&T - 18' 11"
PROPOSED
G
L
A
D
I
O
L
A
S
T
0
P55
P56
N
E
W
6
M
S
T
R
A
N
D
CAUTION
Volts to Ground
35-4
35-4
JEA
JEA
See Dwg #13
E
O
P
E
O
P
R
/
W
R
/
W
NEW STRAND
PROPOSED AERIAL CABLES LASHED TO
1
5
'
/
1
8
'
1
1
"
M
R
3
5
/
8
P
=
D
E
1
/
6
M
Dwg.of 4514
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
301V-15kV
21
21
0
0
1217
1285
1380
L
I
L
Y
S
T
W PLAZA ST
CATV - 18' 11"
PWR - 23' 1"
PROPOSED HOA - AT&T - 17' 11"
MGNV = Y
37'
P52
NEW 6M STRAND
CAUTION
Volts to Ground
45-3
14'
44'8'
W PLAZA
CABLE PLACEMENT
20'
10'
12'
50'8'
LILY ST
CABLE PLACEMENT
11'
29'
S
e
e
D
w
g
#
1
3
JEA
EOP
EOP
E
O
P
E
O
P
R
/
W
R/W
R/W
NEW STRAND
PROPOSED AERIAL CABLES LASHED TO
1/16M
MR2 3/4
P=DE
8'X17'11"
PLACED BY DIRECTIONAL BORE
PROPOSES 1.5" CONDUITS
T
U
R
N
1
+
0
8
2+80
C/L
R/W
R/W
EOP
EOP
CROSS SECTION
C
/
L
E
O
P
E
O
P
R
/
W
R
/
W
C/L
R/W
R/W
EOP
EOP
W PLAZA ST
CROSS SECTION
C
/
L
E
O
P
E
O
P
R
/
W
R
/
W
LILY ST
ROW
HANDHOLE 21' FROM
PROPOSED 10" X 15"
Dwg.of 4515
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
ALL WIDTHS VARY
ALL WIDTHS VARY
50'
25'
12'
25'
36"
29'11'
44'
22'
14'
22'
36"
2'
10'20'
21'
301V-15kV
20
20
21
21
BURIED CABLE
PROPOSED
BURIED CABLE
PROPOSED
min.
B B
FOR DETAILS
SEE DWG
Directional Bore Detail - No Drainage Ditch Involved
PARALLEL INSTALLATION
36"min.36"36"
0
1431
1441
1455
1469
0
B
E
G
O
N
I
A
S
T
B
K
M
S
-
2
5
B
K
M
S
-
1
0
0
1 0
0
'
1 0
0
'
AT&T - 17' 3"
AT&T - 18' 3"
AT&T - 15' 8"
AT&T - 17'
P44
P45
6
M
S
T
R
A
N
D
MGNV = Y
MGNV = Y
HOA
HOA
CAUTION
Volts to Ground
45-3
45-3
JEA
JEA
See Dwg #7
See Dwg #17
E
O
P
E
O
P
R
/
W
R
/
W
EXISTING AERIAL CABLES
PROPOSED AERIAL CABLES LASHED TO
Dwg.of 4516
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
301V-15kV
19
19
0 1469
1487
1486
LEVY
RD
B
K
M
S
-
1
0
0
B
K
M
S
-
2
5
A
N
M
W
-
1
0
0
20'
50'
21'7'
BEGONIA ST
CABLE PLACEMENT
9'
20'
11'
50'
16'
14'
LEVY RD
CABLE PLACEMENT
6
M
S
T
R
A
N
D
MGNV = Y
AT&T - 18' 4"
AT&T - 19' 5"
P46
HOA
CAUTION
Volts to Ground
D
/W
BURY DEPTH
3' TO
POLE
20' UP
45-3
0+00
B
E
G
O
N
I
A
S
T
0
+
8
8
B B
min.min.
VARIES
E
O
P
E
O
P
Bore Detail - NO Drainage Ditch Involved
DRIVEWAY - LEVY RD
36"min.48"
min.
36"min.
6' 6'
JEA
See Dwg #16
S
e
e
D
w
g
#
1
8
E
O
P
E
O
P
EOP
EOP
EOP
EOP
R/W
R
/
W
R
/
W
R/W
R/W
C/L
R/W
R/W
EOP
EOP
C/L
R/W
R/W
EOP
EOP
S/W
R/W
EXISTING AERIAL CABLES
PROPOSED AERIAL CABLES LASHED TO
1
/
1
0
M
7
'
/
1
9
'
1
1
"
1
/
1
0
M
1
0
'
/
1
8
'
4
"
1
/
1
0
M
M
R
3
-
5
/
8
P
=
D
E
7
'
/
1
9
'
5
"
M
R
1
-
1
P
=
D
E
BY DIRECTIONAL BORE
PLACED @ 36" MIN DEPTH
PROPOSED BURIED FIBER CABLE
LEVY RD
CROSS SECTION
C
/
L
E
O
P
E
O
P
R
/
W
R
/
W
BEGONIA ST
CROSS SECTION
C
/
L
E
O
P
E
O
P
R
/
W
R
/
W
Dwg.of 4517
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
ALL WIDTHS VARY
ALL WIDTHS VARY
50'
25'
20'
25'
36"
3'
14'16'
50'
25'
20'
25'
36"
2'
9'21'
301V-15kV
19
19
22
22
BURIED CABLE
PROPOSED
WATER
BURIED CABLE
PROPOSED
WATERSEWER
min.
B B
FOR DETAILS
SEE DWG
Directional Bore Detail - No Drainage Ditch Involved
PARALLEL INSTALLATION
36"min.36"36"
1486
L
A
U
R
E
L
W
A
Y
LEVY
RD
A
N
M
W
-
2
5
0+00
20'
13'
50'
15'
15'
LAUREL WAY
CABLE PLACEMENT
20''
11'
50'
15'
15'
LEVY RD
CABLE PLACEMENT
ANMW-100
ANMW-25
D/W
3
+
7
8
3
+
6
8
3
+
2
8
1487
1488
B B
min.min.
VARIES
E
O
P
E
O
P
LAUREL WAY
Bore Detail - NO Drainage Ditch Involved
36"min.48"
min.
36"min.
6' 6'
S
e
e
D
w
g
#
1
7
See Dwg #19
S
e
e
D
w
g
#
2
1
E
O
P
E
O
P
EOP
EOP
EOP
EOP
R/W
R/W
R
/
W
R
/
W
R/W
R/W
C/L
R/W
R/W
EOP
EOP
C/L
R/W
R/W
EOP
EOP
S/W
DIRECTIONAL BORE
PLACED @ 36" MIN DEPTH BY
PROPOSED BURIED FIBER CABLES
LEVY RD
CROSS SECTION
C
/
L
E
O
P
E
O
P
R
/
W
R
/
W
ROW
HANDHOLE 4' FROM
PROPOSED 17" X 30"
LAUREL WAY
CROSS SECTION
C
/
L
E
O
P
E
O
P
R
/
W
R
/
W
Dwg.of 4518
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
ALL WIDTHS VARY ALL WIDTHS VARY
50'
25'
20'
25'
36"
4'
15'15'
50'
25'
20'
25'
36"
2'
15'15'
23
23
24
24
22
22
BURIED CABLE
PROPOSED
WATER
min.
B B
FOR DETAILS
SEE DWG
Directional Bore Detail - No Drainage Ditch Involved
PARALLEL INSTALLATION
36"min.36"36"
BURIED CABLE
PROPOSED
WATER
20'
13'
50'
15'
15'
LAUREL WAY
CABLE PLACEMENT
14871488
14831484
1480 1479
14751476
L
A
U
R
E
L
W
A
Y
A
N
M
W
-
2
5
D/W
D/W
D/W
D/W
D/W
D/W
D/W
0
+
4
5
0
+
0
0
0
+
0
0
0
+
4
5
0
+
1
5
0
+
3
5
0
+
1
5
0
+
3
5
0+75
1+90
B B
min.min.
20'
E
O
P
E
O
P
LAUREL WAY
Bore Detail - NO Drainage Ditch Involved
36"min.48"
min.
36"min.
6' 6'
B B
min.min.
VARIES
E
O
P
E
O
P
Bore Detail - NO Drainage Ditch Involved
DRIVEWAY
36"min.36"
min.
36"min.
6' 6'
C/L
R/W
R/W
EOP
EOP
See Dwg #18
See Dwg #20
E
O
P
E
O
P
R
/
W
R
/
W
PLACED BY DIRECTIONAL BORE
PROPOSES 1.5" CONDUITS
BY DIRECTIONAL BORE
PLACED @ 36" MIN DEPTH
PROPOSED BURIED FIBER CABLE
LAUREL WAY
CROSS SECTION
C
/
L
E
O
P
E
O
P
R
/
W
R
/
W
ROW
HANDHOLE 2' FROM
PROPOSED 10" X 15"
ROW
HANDHOLE 2' FROM
PROPOSED 10" X 15"
ROW
HANDHOLE 3' FROM
PROPOSED 10" X 15"
HANDHOLE 3' FROM ROW
PROPOSED 10" X 15"
Dwg.of 4519
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
ALL WIDTHS VARY
50'
25'
20'
25'
36"
2'
15'15'
23
23
78
78
79
79
80
82
83
BURIED CABLE
PROPOSED
WATER
min.
B B
FOR DETAILS
SEE DWG
Directional Bore Detail - No Drainage Ditch Involved
PARALLEL INSTALLATION
36"min.36"36"
1472
1468 1467
L
A
U
R
A
L
W
A
Y
1471
20'
13'
50'
15'
15'
LAUREL WAY
CABLE PLACEMENT
D/W
D/W
3+07
0+00
1+03
B B
min.min.
VARIES
E
O
P
E
O
P
Bore Detail - NO Drainage Ditch Involved
DRIVEWAY
36"min.36"
min.
36"min.
6' 6'
See Dwg #19
EOP
R/
W
C/L
R/W
R/W
EOP
EOP
PLACED BY DIRECTIONAL BORE
PROPOSES 1.5" CONDUITS
BY DIRECTIONAL BORE
PLACED @ 36" MIN DEPTH
PROPOSED BURIED FIBER CABLE
LAUREL WAY
CROSS SECTION
C
/
L
E
O
P
E
O
P
R
/
W
R
/
W
HANDHOLE 3' FROM ROW
PROPOSED 10" X 15"
HANDHOLE 2' FROM ROW
PROPOSED 10" X 15"
Dwg.of 4520
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
ALL WIDTHS VARY
50'
25'
20'
25'
36"
2'
15'15'
83
83
23
23
BURIED CABLE
PROPOSED
WATER
min.
B B
FOR DETAILS
SEE DWG
Directional Bore Detail - No Drainage Ditch Involved
PARALLEL INSTALLATION
36"min.36"36"
1490
LEVY
RD
ANMW-25
M
A
R
S
H
V
I
E
W
C
T
20'
11'
50'
15'
15'
LEVY RD
CABLE PLACEMENT
20'
13'
50'
15'
15'
12'
MARSH VIEW CT
CABLE PLACEMENT
D/W
D/W
0+50
1489
B B
min.min.
VARIES
E
O
P
E
O
P
Bore Detail - NO Drainage Ditch Involved
DRIVEWAY
36"min.36"
min.
36"min.
6' 6'
S
e
e
D
w
g
#
1
8
See Dwg #22
EOP
EOP
E
O
P
E
O
P
R/W
R/W
R
/
W
R
/
W
C/L
R/W
R/W
EOP
EOP
C/L
R/W
R/W
EOP
EOP
PLACED BY DIRECTIONAL BORE
PROPOSES 1.5" CONDUIT
BY DIRECTIONAL BORE
PLACED @ 36" MIN DEPTH
PROPOSED BURIED FIBER CABLE
ROW
HANDHOLE 2' FROM
PROPOSED 10" X 15"
LEVY RD
CROSS SECTION
C
/
L
E
O
P
E
O
P
R
/
W
R
/
W
MARSH VIEW CT
CROSS SECTION
C
/
L
E
O
P
E
O
P
R
/
W
R
/
W
Dwg.of 4521
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
ALL WIDTHS VARY
ALL WIDTHS VARY
50'
25'
20'
25'
36"
4'
15'15'
50'
25'
20'
25'
36"
3'
15'15'
36"
2'
24
24
105
105
BURIED CABLE
PROPOSED WATERSEWER
BURIED CABLE
PROPOSED WATERSEWER
BURIED CABLE
PROPOSED
1486
14851482
1478 1481
14771474
ANMW-25
20'
13'
50'
15'
15'
12'
MARSH VIEW CT
CABLE PLACEMENT
A
N
M
W
-
2
5
D/W
D/W
D/W
D/W
D/W
D/W
D/W
0
+
0
0
0
+
0
0
0
+
0
0
0+00
0+00
1489
0
+
4
5
0
+
4
5
0
+
4
5
0
+
1
2
0
+
3
2
0
+
1
2
0
+
3
2
0
+
1
2
0
+
3
2
8+43
6+70
7+84
M
A
R
S
H
V
I
E
W
C
T
B B
min.min.
VARIES
E
O
P
E
O
P
Bore Detail - NO Drainage Ditch Involved
DRIVEWAY
36"min.36"
min.
36"min.
6' 6'
B B
min.min.
20'
E
O
P
E
O
P
Bore Detail - NO Drainage Ditch Involved
36"min.48"
min.
36"min.
6' 6'
See Dwg #21
See Dwg #23
E
O
P
E
O
P
R
/
W
R
/
W
C/L
R/W
R/W
EOP
EOP
PLACED BY DIRECTIONAL BORE
PROPOSES 1.5" CONDUITS
BY DIRECTIONAL BORE
PLACED @ 36" MIN DEPTH
PROPOSED BURIED FIBER CABLE
ROW
HANDHOLE 3' FROM
PROPOSED 10" X 15"
ROW
HANDHOLE 2' FROM
PROPOSED 10" X 15"
ROW
HANDHOLE 3' FROM
PROPOSED 10" X 15"
HANDHOLE 2' FROM ROW
PROPOSED 10" X 15"
HANDHOLE 3' FROM ROW
PROPOSED 10" X 15"
ROW
HANDHOLE 2' FROM
PROPOSED 10" X 15"
MARSH VIEW CT
CROSS SECTION
C
/
L
E
O
P
E
O
P
R
/
W
R
/
W
Dwg.of 4522
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
ALL WIDTHS VARY
50'
25'
20'
25'
36"
3'
15'15'
36"
2'
24
24
84
84
86
86
87
87
105
105
85
85
BURIED CABLE
PROPOSED WATERSEWER
BURIED CABLE
PROPOSED
1469
M
A
R
S
H
V
I
E
W
C
T
20'
50'
15'
15'
12'
MARSH VIEW CT
CABLE PLACEMENT
D/W
D/W
0+70
VACANT
B B
min.min.
VARIES
E
O
P
E
O
P
Bore Detail - NO Drainage Ditch Involved
DRIVEWAY
36"min.36"
min.
36"min.
6' 6'
See Dwg #22
EOP
R/W
C/L
R/W
R/W
EOP
EOP
PLACED BY DIRECTIONAL BORE
PROPOSES 1.5" CONDUITS
HANDHOLE 3' FROM ROW
PROPOSED 10" X 15"
MARSH VIEW CT
CROSS SECTION
C
/
L
E
O
P
E
O
P
R
/
W
R
/
W
Dwg.of 4523
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
ALL WIDTHS VARY
50'
25'
20'
25'
36"
3'
15'15'
87
87
BURIED CABLE
PROPOSED WATERSEWER
750
1335
1222
1315
1245
1275
J
A
S
M
I
N
E
S
T
A
F
M
W
-
2
5
820
20'
12'
50'
14'
16'
JASMINE ST
CABLE PLACEMENT
D/W
D/W
D/W
D/W
D/W
DROPS
BY AERIAL
HOMES FED
3+41
0
+
0
0
0
+
4
6
0+00
0+50
0
+
1
2
0
+
3
2
1+35
B B
min.min.
20'
E
O
P
E
O
P
Bore Detail - NO Drainage Ditch Involved
36"min.48"
min.
36"min.
6' 6'
B B
min.min.
VARIES
E
O
P
E
O
P
Bore Detail - NO Drainage Ditch Involved
DRIVEWAY
36"min.36"
min.
36"min.
6' 6'
See Dwg #6
See Dwg #25
E
O
P
E
O
P
C/L
R/W
R/W
EOP
EOP
R
/
W
R
/
W
PLACED BY DIRECTIONAL BORE
PROPOSES 1.5" CONDUITS
BY DIRECTIONAL BORE
PLACED @ 36" MIN DEPTH
PROPOSED BURIED FIBER CABLE
JASMINE ST
CROSS SECTION
C
/
L
E
O
P
E
O
P
R
/
W
R
/
W
ROW
HANDHOLE 2' FROM
PROPOSED 10" X 15"
ROW
HANDHOLE 2' FROM
PROPOSED 10" X 15"
ROW
HANDHOLE 2' FROM
PROPOSED 10" X 15"
ROW
HANDHOLE 2' FROM
PROPOSED 10" X 15"
Dwg.of 4524
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
JASMINE ST
ALL WIDTHS VARY
50'
25'
20'
25'
36"
2'
14'16'
16
16
74
74
75
75
BURIED CABLE
PROPOSED
WATER
SEWER
1212
1223
1202
1221
1219
1217
0
20'
12'
50'
14'
16'
JASMINE ST
CABLE PLACEMENT
A
F
M
W
-
2
5
CAUTION
Volts to Ground
D/W
D/W
D/W
D/W
D/W
DROPS
BY AERIAL
HOMES FED
4+40
J
A
S
M
I
N
E
S
T
B B
min.min.
VARIES
E
O
P
E
O
P
Bore Detail - NO Drainage Ditch Involved
DRIVEWAY
36"min.36"
min.
36"min.
6' 6'
E
O
P
E
O
P
See Dwg #24
R
/
W
R
/
W
C/L
R/W
R/W
EOP
EOP
BY DIRECTIONAL BORE
PLACED @ 36" MIN DEPTH
PROPOSED BURIED FIBER CABLE
JASMINE ST
CROSS SECTION
C
/
L
E
O
P
E
O
P
R
/
W
R
/
W
ROW
HANDHOLE 2' FROM
PROPOSED 10" X 15"
Dwg.of 4525
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
ALL WIDTHS VARY
50'
25'
20'
25'
36"
2'
14'16'
301V-15kV
16
16
BURIED CABLE
PROPOSED
WATER
SEWER
1465
1464
14471448
1432
1431
14811480
1496 1497
J
A
S
M
I
N
E
S
T
1 0
1 '
1 0
1 '
AT&T - 21' 1"
MGNV = Y
HOA
AT&T - 21' 1"
MGNV = Y
HOA
AT&T - 17' 6"
MGNV = Y
HOA
P40
P41
P42
6
M
S
T
R
A
N
D
CAUTION
Volts to Ground
45-3
45-3
45-3
JEA
JEA
JEA
See Dwg #6
E
O
P
E
O
P
R
/
W
R
/
W
EXISTING AERIAL CABLES
PROPOSED AERIAL CABLES LASHED TO
1
/
1
0
M
1
0
'
/
1
7
'
6
"
M
R
2
-
3
/
4
P
=
D
E
Dwg.of 4526
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
301V-15kV
17
17
1339
720
1357
1380
1349
1285
1303
1370
1350
C
A
M
E
L
I
A
S
T
AT&T - 20' 5"
MGNV = Y
HOA
P35
6
M
S
T
R
A
N
D
CAUTION
Volts to Ground
1087
1320
45-3
JEA
See Dwg #5
E
O
P
E
O
P
R
/
W
R
/
W
EXISTING AERIAL CABLES
PROPOSED AERIAL CABLES LASHED TO
M
R
3
-
5
/
8
P
=
D
E
1
/
1
0
M
1
6
'
/
2
0
'
5
"
Dwg.of 4527
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
301V-15kV
13
13
1464
1448
1432
1480
1496
C
A
M
E
L
I
A
S
T
1 0
1 '
AT&T - 20' 2"
MGNV = Y
HOA
MGNV = Y
HOA AT&T - 21'
P31
AT&T - 20' 6"HOA
MGNV = BROKEN
P36
P37
P38
6
M
S
T
R
A
N
D
CAUTION
Volts to Ground
1 0
0
'
45-3
45-3
50-2
JEA
JEA
JEA
See Dwg #5
E
O
P
E
O
P
R
/
W
R
/
W
EXISTING AERIAL CABLES
PROPOSED AERIAL CABLES LASHED TO
M
R
2
-
3
/
4
P
=
D
E
1
/
1
0
M
1
0
'
/
1
7
'
6
"
Dwg.of 4528
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
301V-15kV
14
14
M
A
I
N
S
T
1395
1374
1372
1276
1285
1305
1335
B
K
M
S
-
2
0
0
MGNV = Y
HOA
MGNV = Y
HOA
9
0
'
AT&T - 22' 1"
AT&T - 22' 5"
P14
P15
6
M
S
T
R
A
N
D
CAUTION
Volts to Ground
1332
1302
1334
1304
50-2
50-2
JEA
JEA
See Dwg #4
See Dwg #30
E
O
P
E
O
P
R
/
W
R
/
W
EXISTING AERIAL CABLES
PROPOSED AERIAL CABLES LASHED TO
Dwg.of 4529
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
301V-15kV
25
25
1232
M
A
I
N
S
T
1236
1237
1187
1155
1186
1166
1156
B
K
M
S
-
2
0
0
MGNV = Y
HOA
MGNV = Y
HOA
8
1 '
1 1 7
'
AT&T - 18' 4"
AT&T - 15' 3"
P16
P17
6
M
S
T
R
A
N
D
CAUTION
Volts to Ground
50-2
45-3
JEA
JEA
See Dwg #29
See Dwg #31
E
O
P
E
O
P
R
/
W
R
/
W
EXISTING AERIAL CABLES
PROPOSED AERIAL CABLES LASHED TO
Dwg.of 4530
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
301V-15kV
25
25
M
A
I
N
S
T
1156
1155
1146
1126
1102
1125
1101
1115
B
K
M
S
-
2
0
0
1 1 5
'
1 2
6
'
MGNV = Y
HOA
MGNV = Y
HOA AT&T - 18' 10"
AT&T - 20'
P18
P19
6
M
S
T
R
A
N
D
CAUTION
Volts to Ground
45-3
45-3
JEA
JEA
See Dwg #32
See Dwg #30
E
O
P
E
O
P
R
/
W
R
/
W
EXISTING AERIAL CABLES
PROPOSED AERIAL CABLES LASHED TO
Dwg.of 4531
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
301V-15kV
25
25
M
A
I
N
S
T
1098 1089
1022
1090
1024
989
995
999
985
1020
979
B
K
M
S
-
1
0
0
MGNV = Y
HOA AT&T - 21' 1"
MGNV = Y
HOA AT&T - 18' 10"
1 4
0
'
1 2
0
'
P20
P21
6
M
S
T
R
A
N
D
CAUTION
Volts to Ground
45-3
45-3
JEA
JEA
See Dwg #31
See Dwg #33
E
O
P
E
O
P
R
/
W
R
/
W
EXISTING AERIAL CABLES
PROPOSED AERIAL CABLES LASHED TO
Dwg.of 4532
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
301V-15kV
25
25
M
A
I
N
S
T
1020
975
1018
950
940
969
935
955
949
945
9250
965
MGNV = Y
MGNV = Y
B
K
M
S
-
1
0
0
AT&T - 20'
HOA AT&T - 19' 5"
HOA
9
4
'
1 0
6
'
1 1 5
'
P22
P23
6
M
S
T
R
A
N
D
CAUTION
Volts to Ground
45-3
45-3
JEA
JEA
See Dwg #32
See Dwg #34
E
O
P
E
O
P
R
/
W
R
/
W
EXISTING AERIAL CABLES
PROPOSED AERIAL CABLES LASHED TO
Dwg.of 4533
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
301V-15kV
25
25
M
A
I
N
S
T
925
B
K
M
S
-
1
0
0
BKMS-100
-
5
0
S
T
U
B
ANMW-50
150'
1 2
7
'
22'
50'
10'
13'
6
M
S
T
R
A
N
D
0
+
0
0
MGNV = Y
MGNV = Y
AT&T - 18' 6"
AT&T - 18' 10"
P24
P25
9'
HOA
HOA
CAUTION
Volts to Ground
439
DEPTH
TO BURY
POLE 3'
19' UP
45-3
45-3
VACANT
VACANT
1-16M
12'X18'6"MR2-3/4
P=DE
9TH ST W
CABLE PLACEMENT
B B
min.min.
VARIES
E
O
P
E
O
P
Bore Detail - NO Drainage Ditch Involved
DRIVEWAY
36"min.36"
min.
36"min.
6' 6'JEA
See Dwg #33
S
e
e
D
w
g
#
3
5
JEA
E
O
P
E
O
P
EOP
EOP
E
O
P
E
O
P
EOP
EOP
R
/
W
R/W
R/W
R
/
W
R
/
W
R/W
R/W
C/L
R/W
R/W
EOP
EOP
R
/
W
EXISTING AERIAL CABLES
PROPOSED AERIAL CABLES LASHED TO
BY DIRECTIONAL BORE
PLACED @ 36" MIN DEPTH
PROPOSED BURIED FIBER CABLE
R
/
W
9TH ST W
CROSS SECTION
C
/
L
E
O
P
E
O
P
R
/
W
Dwg.of 4534
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
9TH ST W
ALL WIDTHS VARY
50'
25'
22'
25'
36"
1'
10'13'
301V-15kV
25
25
26
26
BURIED CABLE
PROPOSED
WATER
SEWER
917
907
906
954
927
S
T
O
C
K
S
S
T
S
T
R
A
N
D
N
E
W
6
M
934
CATV - 18' 8"
PWR - 26' 8"
PROPOSED HOA - AT&T - 17' 8"
MGNV = Y
P27
2
+
1
7
DEPTH
3' BURY
POLE
18' UP
D/W
D/W
45-3
MR2-3/4
P=DE
1
-
1
0
M
6
'
/
8
'
DOWN-GUY
SIDEWALK
3+39
24'
10'
50'
17'
13'
STOCKS ST
CABLE PLACEMENT
22'
50'
10'
13'
9TH ST W
CABLE PLACEMENT
9'
CAUTION
Volts to Ground
B B
min.min.
VARIES
E
O
P
E
O
P
Bore Detail - NO Drainage Ditch Involved
DRIVEWAY
36"min.36"
min.
36"min.
6' 6'
JEA
See Dwg #36
S
e
e
D
w
g
#
3
4
EOP
EOP
E
O
P
E
O
P
EOP
EOP
E
O
P
E
O
P
R/W
R/W R/W
R/W
R
/
W
R
/
W
R
/
W
R
/
W
NEW STRAND
PROPOSED AERIAL CABLES LASHED TO
BY DIRECTIONAL BORE
PLACED @ 36" MIN DEPTH
PROPOSED BURIED FIBER CABLE
C/L
R/W
R/W
EOP
EOP
S/W
C/L
R/W
R/W
EOP
EOP
R
/
W
9TH ST W
CROSS SECTION
C
/
L
E
O
P
E
O
P
R
/
W
R
/
W
CROSS SECTION
C
/
L
E
O
P
E
O
P
R
/
W
STOCKS ST
Dwg.of 4535
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
9TH ST W
ALL WIDTHS VARY
ALL WIDTHS VARY
50'
25'
22'
25'
36"
1'
10'13'
50'
25'
24'
25'
36"
7'
17'13'
301V-15kV
26
26
27
27
BURIED CABLE
PROPOSED
WATER
SEWER
BURIED CABLE
PROPOSED
WATER
SEWER
1044 1045
996
974
1035
995
985
927954
0
1034
986
S
T
O
C
K
S
S
T
1 3
2
'
5
0
'
9
9
'
CATV - 20' 9"
PWR - 25' 6"
MGNV = Y
CATV - 20' 6"
PWR - 24' 9"
MGNV = Y
PROPOSED HOA - AT&T - 19' 9"
PROPOSED HOA - AT&T - 19' 6"
P28
P29
CAUTION
Volts to Ground
N
E
W
6
M
S
T
R
A
N
D
45-3
45-3
JEA
See Dwg #35
See Dwg #37
JEA
E
O
P
E
O
P
R
/
W
R
/
W
NEW STRAND
PROPOSED AERIAL CABLES LASHED TO
Dwg.of 4536
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
301V-15kV
27
27
1094
1083
1074
1054
1064
1073
1071
1065
1055
1044
S
T
O
C
K
S
S
T
CATV - 20' 3"
PWR - 25' 6"
MGNV = Y
PROPOSED HOA - AT&T - 19'
PROPOSED HOA - AT&T - 19'
CATV - 20' 1"
PWR - 26' 1"
MGNV = Y
PROPOSED HOA - AT&T - 22'
MGNV = Y
CATV - 23'
PWR - 27'
5
2
'
7
0
'
N
E
W
6
M
S
T
R
A
N
D
P30
P31
P32
CAUTION
Volts to Ground
45-3
35-4
45-3
1
-
6
M
1
5
'
/
1
9
'
M
R
3
-
5
/
8
P
=
D
E
JEA
JEA
See Dwg #36
JEA
E
O
P
E
O
P
R
/
W R
/
W
NEW STRAND
PROPOSED AERIAL CABLES LASHED TO
Dwg.of 4537
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
301V-15kV
27
27
589
1500
1540
MEMORIAL DR
M
A
I
N
S
T
S
R
-
5
B
Q
2
M
T
-
0
2
4
A
F
M
W
-
2
0
0
A
N
T
W
-
5
0
A
N
M
W
-
1
0
0
B
K
M
A
-
5
0
MGNV = Y
HOA
4
3
'
1 5
6
'
AT&T - 20' 6"
MGNV = Y
HOA AT&T - 18' 7"
MGNV = Y
HOA AT&T - 18' 7"
ANTW-50
P3
P4
P5
6
M
S
T
R
A
N
D
CAUTION
Volts to Ground
8
8
50-2
50-2
50-2
JEA
JEA
JEA
See Dwg #3
See Dwg #39
EOP
EOP
E
O
P
E
O
P
R/W
R/W
R
/
W
R
/
W
R
/
W
EXISTING AERIAL CABLES
PROPOSED AERIAL CABLES LASHED TO
Dwg.of 4538
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
301V-15kV
28
28
1550
1660
1570
1541 & 1543
1545
1571
KESTNER RD
M
A
I
N
S
T
A
F
M
W
-
2
0
0
A
F
M
W
-
2
5
A
F
M
W
-
2
0
0
ANTW-50
ANMW-100
AJMW-50
ANMW-100
ANMW-100
B
K
M
A
-
5
0
SR-5BQ2MT-024
1 4
0
'
2
3
1 '
0+00
MGNV = Y
HOA AT&T - 18' 3"
MGNV = Y
HOA AT&T - 20' 7"
C
B
K
M
A
-
5
0
B
K
M
A
-
5
0
B
K
T
S
-
5
0
1662
P6
P7
9
6
'
DEPTH
BURY
3' TO
POLE
21' UP
CAUTION
Volts to Ground
50-2
0
+
3
0
0
+
3
7
0
+
6
6
26'
60'
16'
18'
16'
12'54'
16'
22'
KESTNER RD
CABLE PLACEMENT
9'
MAIN ST
CABLE PLACEMENT
B B
min.min.
26"
E
O
P
E
O
P
Bore Detail - NO Drainage Ditch Involved
36"min.48"
min.
36"min.
6' 6'
JEA
See Dwg #38
See Dwg #40
S
e
e
D
w
g
#
4
4
JEA
E
O
P
E
O
P
EOP
EOP
R/W
R/W
R
/
W
R
/
W
EXISTING AERIAL CABLES
PROPOSED AERIAL CABLES LASHED TO
CONDUIT
PROPOSED 4" X 33'
BY DIRECTIONAL BORE
PLACED @ 36" MIN DEPTH
PROPOSED BURIED FIBER CABLE
R/W
R/W
C/L
EOP
EOP
C/L
R/W
R/W
EOP
EOP
R
/
W
MAIN ST
CROSS SECTION
C
/
L
E
O
P
E
O
P
R
/
W
R
/
W
KESTNER RD
CROSS SECTION
C
/
L
E
O
P
E
O
P
R
/
W
Dwg.of 4539
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
ALL WIDTHS VARY
ALL WIDTHS VARY
60'
30'
26'
30'
36"
9'
18'16'
54'
27'
16'
27'
36"
10'
22'16'
301V-15kV
28
28
29
29
BURIED CABLE
PROPOSED
WATER
SEWER
BURIED CABLE
PROPOSED
WATER
SEWER
PARADISE CT
601
602
1575
1589
1601
1630
1640
M
A
I
N
S
T
0+00
9
1 '
1 2
8
'
MGNV = Y
HOA AT&T - 21' 10"
MGNV = Y
HOA AT&T - 22' 2"
MGNV = Y
HOA AT&T - 22' 6"
B
K
M
A
-
5
0
B
K
M
A
-
5
0
B
K
T
S
-
5
0
1 8
8
'
ANTW-50
P10
P8
P9
6
M
S
T
R
A
N
D
DEPTH
BURY
3' TO
POLE
23' UP
CAUTION
Volts to Ground
0
+
5
9
50-2
50-3
50-3
0
+
8
3
T
U
R
N
0
+
5
1
26'
60'
16'
18'
8'
MAIN ST
CABLE PLACEMENT
B B
min.min.
VARIES
E
O
P
E
O
P
Bore Detail - NO Drainage Ditch Involved
36"min.48"
min.
36"min.
6' 6'
20'
60'
14'
26'
5'
PARADISE CT
CABLE PLACEMENT
JEA
JEA
JEA
See Dwg #39
See Dwg #41
S
e
e
D
w
g
#
4
2
E
O
P
E
O
P
EOP
EOP
R
/
W
R
/
W
R/W
R/W
EXISTING AERIAL CABLES
PROPOSED AERIAL CABLES LASHED TO
CONDUIT
PROPOSED 4" X 37'
BY DIRECTIONAL BORE
PLACED @ 36" MIN DEPTH
PROPOSED BURIED FIBER CABLE
R
/
W
PARADISE CT
CROSS SECTION
C
/
L
E
O
P
E
O
P
R
/
W
C/L
R/W
R/W
EOP
EOP
C/L
R/W
R/W
EOP
EOP
R
/
W
MAIN ST
CROSS SECTION
C
/
L
E
O
P
E
O
P
R
/
W
Dwg.of 4540
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
ALL WIDTHS VARY
ALL WIDTHS VARY
60'
30'
20'
30'
36"
21'
26'14'
60'
30'
26'
30'
36"
10'
18'16'
301V-15kV
28
28
30
30
BURIED CABLE
PROPOSED
WATERSEWER
BURIED CABLE
PROPOSED
WATER
SEWER
1601
1611
1642
1640
M
A
I
N
S
T
STEWART ST
MGNV = Y
HOA AT&T - 19' 8"
P11
CAUTION
Volts to Ground
6
M
S
T
R
A
N
D
50-3
JEA
See Dwg #40
EOP
EOP EOP
EOP
E
O
P
E
O
P
E
O
P
E
O
P
R/W
R/W R/W
R/W
R
/
W
R
/
W
EXISTING AERIAL CABLES
PROPOSED AERIAL CABLES LASHED TO
Dwg.of 4541
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
301V-15kV
28
28
20'
60'
14'
26'
7'
5'
PARADISE CT
CABLE PLACEMENT
PARADISE CT
605607609611
612 610 608 606 604
ANTW-50
603
D
/
W
D
/
W
D
/
W
D
/
W
D
/
W
1
+
7
6
3
+
8
2
2
+
7
9
0+00
0+320+32
0+00
0+32
0+00
0+05
0+25
0+05
0+25
0+05
0+25
B B
min.min.
20'
E
O
P
E
O
P
Bore Detail - NO Drainage Ditch Involved
36"min.48"
min.
36"min.
6' 6'
C/L
R/W
R/W
EOP
EOP
S
e
e
D
w
g
#
4
0
S
e
e
D
w
g
#
4
3
R/W
R/W
EOP
EOP
PLACED BY DIRECTIONAL BORE
PROPOSES 1.5" CONDUITS
BY DIRECTIONAL BORE
PLACED @ 36" MIN DEPTH
PROPOSED BURIED FIBER CABLE
ROW
HANDHOLE 7' FROM
PROPOSED 10" X 15"
ROW
HANDHOLE 7' FROM
PROPOSED 10" X 15"
ROW
HANDHOLE 7' FROM
PROPOSED 10" X 15"
ROW
HANDHOLE 21' FROM
PROPOSED 10" X 15"
ROW
HANDHOLE 21' FROM
PROPOSED 10" X 15"
ROW
HANDHOLE 21' FROM
PROPOSED 10" X 15"
R
/
W
PARADISE CT
CROSS SECTION
C
/
L
E
O
P
E
O
P
R
/
W
Dwg.of 4542
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
ALL WIDTHS VARY
60'
30'
20'
30'
36"
21'
26'14'
30
30
88
88
89
89
91
91
BURIED CABLE
PROPOSED
WATER SEWER
613615617619621
622 620 618 616 614
20'
60'
14'
26'
7'
5'
PARADISE CT
CABLE PLACEMENT
D
/
W
D
/
W
D
/
W
D
/
W
D/
W
D /W
PARADISE CT
5
+
9
5
ANTW-50
4
+
8
4
0+32
0+00
0+55
0+00
0
+
0
0
0+05
0+25
1+12
0+48
0+07
B B
min.min.
20'
E
O
P
E
O
P
Bore Detail - NO Drainage Ditch Involved
36"min.36"
min.
36"min.
6' 6'
S
e
e
D
w
g
#
4
2
EOP
EOP
R/W
R/W
C/L
R/W
R/W
EOP
EOP
PLACED BY DIRECTIONAL BORE
PROPOSES 1.5" CONDUITS
BY DIRECTIONAL BORE
PLACED @ 36" MIN DEPTH
PROPOSED BURIED FIBER CABLE
ROW
HANDHOLE 21' FROM
PROPOSED 10" X 15"
ROW
HANDHOLE 21' FROM
PROPOSED 10" X 15"
ROW
HANDHOLE 21' FROM
PROPOSED 10" X 15"
ROW
HANDHOLE 7' FROM
PROPOSED 10" X 15"
ROW
HANDHOLE 7' FROM
PROPOSED 10" X 15"
R
/
W
PARADISE CT
CROSS SECTION
C
/
L
E
O
P
E
O
P
R
/
W
Dwg.of 4543
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
ALL WIDTHS VARY
60'
30'
20'
30'
36"
21'
26'14'
30
30
95
95
96
94
94
108
108
BURIED CABLE
PROPOSEDWATER SEWER
602
606608610612
708 706 696 1570
KESTNER RD
604
698
AJMW-50
A
L
A
W
-
2
0
0
AJMW-50
2
+
7
0
702704
FROM PARADISE CT
KESTNER RD ARE SERVED
HOMES ON NORTH SIDE OF
ANMW-25
16'
12'54'
16'
22'
KESTNER RD
CABLE PLACEMENT
D
/
W
D
/
W
D
/
W
D
/
W
3
+
8
5
B B
min.min.
VARIES
E
O
P
E
O
P
Bore Detail - NO Drainage Ditch Involved
DRIVEWAY
36"min.36"
min.
36"min.
6' 6'
S
e
e
D
w
g
#
3
9
S
e
e
D
w
g
#
4
5
EOP
EOP
R/W
R/W
R/W
R/W
C/L
EOP
EOP
PLACED BY DIRECTIONAL BORE
PROPOSES 1.5" CONDUITS
BY DIRECTIONAL BORE
PLACED @ 36" MIN DEPTH
PROPOSED BURIED FIBER CABLE
ROW
HANDHOLE 10' FROM
PROPOSED 10" X 15"
ROW
HANDHOLE 10' FROM
PROPOSED 10" X 15"
R
/
W
KESTNER RD
CROSS SECTION
C
/
L
E
O
P
E
O
P
R
/
W
Dwg.of 4544
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
ALL WIDTHS VARY
54'
27'
16'
27'
36"
10'
22'16'
97
29
29
BURIED CABLE
PROPOSED
WATER
SEWER
614618
712 710
KESTNER RD
616
FROM PARADISE CT
KESTNER RD ARE SERVED
HOMES ON NORTH SIDE OF
ANMW-50
16'
12'54'
16'
22'
KESTNER RD
CABLE PLACEMENT
D
/
W
D
/
W 4
+
8
9
B B
min.min.
VARIES
E
O
P
E
O
P
Bore Detail - NO Drainage Ditch Involved
DRIVEWAY
36"min.36"
min.
36"min.
6' 6'
S
e
e
D
w
g
#
4
4
R/W
R/W
C/L
R/W
R/W
EOP
EOP
EOP
EOP
BY DIRECTIONAL BORE
PLACED @ 36" MIN DEPTH
PROPOSED BURIED FIBER CABLE
ROW
HANDHOLE 10' FROM
PROPOSED 10" X 15"
R
/
W
KESTNER RD
CROSS SECTION
C
/
L
E
O
P
E
O
P
R
/
W
Dwg.of 4545
12E68017N
Exchange:
Designer:
305-929-2166
904246
Hernandez,Javier
Phone:
Authorization:
ATLANTIC BEACH CITY
601 LEVY RD
ON RIGHT OF WAY OF
PROPOSED TELEPHONE FACILITIES
ATTSE
ALL WIDTHS VARY
54'
27'
16'
27'
36"
10'
22'16'
29
29
BURIED CABLE
PROPOSED
WATER
SEWER