305 Ahern St ROW20-0029 underground cable permitOWNER:ADDRESS:CITY:STATE:ZIP:
AHERN TH PROJECT LLC 830 13 A1A N #120 PONTE VEDRA
BEACH FL 32082
COMPANY:ADDRESS:CITY:STATE:ZIP:
Fiber Core Group for
COMCAST
TYPE OF
CONSTRUCTION:
REAL ESTATE
NUMBER:ZONING:BUILDING USE
GROUP:SUBDIVISION:
169737 0010 ATLANTIC BEACH
JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK:
305 AHERN ST RIGHT OF WAY SINGLE OR TWO
FAMILY RIGHT OF WAY
PROPOSED UG CATV
FACILITIES $0.00
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
1 PUBLIC UTILITIES UNDERGROUND WATER SEWER UTILITIES INFORMATIONAL
Notes:
Avoid damage to underground water and sewer utilities. Verify vertical and horizontal location of utilities. Hand dig if necessary. If field coordination is
needed, call 247-5878.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN
YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT
MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU
INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT.
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
1 of 2Issued Date: 10/6/2020
PERMIT NUMBER
ROW20-0029
ISSUED: 10/6/2020
EXPIRES: 1/4/2021
RIGHT OF WAY PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
TOTAL:
2 PUBLIC UTILITIES UTILITY MAP INFORMATIONAL
Notes:
See attached Utility Map.
3 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL
Notes:
All runoff must remain on-site during construction.
4 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL
Notes:
Roll off container company must be on City approved list. Approved list can be obtained at the Building Department at City Hall. Roll off container
cannot be placed on City right-of-way.
5 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL
Notes:
Full right-of-way restoration, including sod, is required.
6 PUBLIC WORKS INFRASTRUCTURE INFORMATIONAL
Notes:
Any damage done to infrastructure must be repaired by Contractor.
7 PUBLIC WORKS AS-BUILT INFORMATIONAL
Notes:
Contractor must submit As-Built plans to City within 30 days after completion of project.
2 of 2Issued Date: 10/6/2020
PERMIT NUMBER
ROW20-0029
ISSUED: 10/6/2020
EXPIRES: 1/4/2021
RIGHT OF WAY PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
ROW20-0029
PROPOSED UG CATV / FIBERFACILITIES IN DUVAL COUNTY, FLORIDAVICINITY VIEWCITY:COUNTY:SCALE:STATE:DATE:DRAWN:NOT TO SCALE1 OF 8DUVALFIBER CORE GROUP09-25-2020FLORIDASHEET NO:CITY OF ATLANTIC BEACHRIGHT-OF-WAYPERMITCOMCASTSTREET LIGHTPOWERCATVWATERSEWERPHONEPROPOSED AERIALCONCRETE POLEWOOD POLERISER POLEPEDESTALVAULTANCHORS/LS/LS/LEWATERSEWERCRVJOINT USAGE POLETRANSFORMER POLERIGHT OF WAYPROPOSED TRENCHPROPOSED BOREGASDBDBDBCULVERT4'X4'X4' BORE PITAAAEEGASGASPHONEPHONEATLANTIC BEACHCATVCATVBEGINENDVICINITY MAP305 AHERN ST, ATLANTIC BEACH, FL 32233JOB NUMBER:PROJECT TOTALSPROPOSED AERIAL FOOTAGEPROPOSED UG CATV/FIBERTOTAL FOOTAGE0'TOTAL PROPOSED BORES130'JB0000446433PROPOSED PED1PROPOSED BORE PITS030'SANTAROSACOUNTYOKALOOSACOUNTYWALTONCOUNTYHOLMESCOUNTYWASHINGTONCOUNTYBAYCOUNTYCALHOUNCOUNTYGULFCOUNTYFRANKLINCOUNTYLIBERTYCOUNTYWAKULLACOUNTYGADSDENCOUNTYJEFFERSONCOUNTYMADISONCOUNTYTAYLORCOUNTYHAMILTONCOUNTYSUWANNEECOUNTYCOLUMBIACOUNTY
UNIONCOUNTYLAFAYETTECOUNTYDIXIECOUNTYGILCHRISTCOUNTY
ALACHUACOUNTYLEVYCOUNTYMARIONCOUNTYSUMTERCOUNTYVOLUSIACOUNTYLAKECOUNTYSEMINOLECOUNTYORANGECOUNTYHERNANDOCOUNTYCITRUSCOUNTYPASCOCOUNTYPOLKCOUNTYOSCEOLACOUNTYPINELLASCOUNTYMANATEECOUNTYHARDEECOUNTYDESOTOCOUNTYSARASOTACOUNTYCHARLOTTECOUNTYGLADESCOUNTYHIGHLANDSCOUNTYHENDRYCOUNTYLEECOUNTYCOLLIERCOUNTYBROWARDCOUNTYMIAMI-DADECOUNTYMONROECOUNTYPALMBEACHCOUNTYMARTINCOUNTYSAINTLUCIECOUNTYOKEECHOBEECOUNTYINDIANRIVERCOUNTYBREVARDCOUNTYHILLSBOROUGHCOUNTY COMCAST PERMIT REQUEST FOR305 AHERN ST, ATLANTIC BEACH, FL 32233THESE PLANS WERE PREPARED UNDER THERESPONSIBLE CHARGE OF COMCAST ANDARE EXEMPT FROM THE SIGNING AND SEALINGREQUIREMENTS PRESCRIBED INSECTION 471 OF THE FLORIDA STATUTESBAKERCOUNTYBRADFORDCOUNTYCLAYCOUNTYPUTNAMCOUNTYFLAGLERCOUNTYLEONCOUNTYNASSAUCOUNTYST JOHNSCOUNTYJACKSONCOUNTYDUVALCOUNTYJOB SITE:305 AHERN ST,ATLANTIC BEACH, FL 32233
CITY OF ATLANTIC BEACHRIGHT-OF-WAYPERMITCOMCASTSTREET LIGHTPOWERCATVWATERSEWERPHONEPROPOSED AERIALCONCRETE POLEWOOD POLERISER POLEPEDESTALVAULTANCHORS/LS/LS/LEWATERSEWERCRVJOINT USAGE POLETRANSFORMER POLERIGHT OF WAYPROPOSED TRENCHPROPOSED BOREGASDBDBDBCULVERT4'X4'X4' BORE PITAAAEEGASGASPHONEPHONECATVCATVFENCEWATERSTORM SEWERGASAT&TBURIED POWERPROPOSED TRENCHPROPOSED AERIALRIGHT OF WAYALL UTILITIES LOCATED BYVISUAL INSPECTION, TO BEVERIFIED BY LOCATESEOT REPRESENTS EDGE OFTRAVEL NOT TRUE EDGE OFPAVEMENTE/P REPRESENTS THE TRUEEDGE OF PAVEMENTEOD REPRESENTS THE EDGEOF DIRTHAND DIG TRENCHES 36" DEEPACROSS DIRT ROADNOTESALL PROPOSED CONSTRUCTION WILL BE PERTHE CITY OF ATLANTIC BEACH SPECIFICATIONS AS WELL AS ALL NECESSARY SAFETY CODES.ALL PROPOSED CATV WILL BE WITHIN THECITY OF ATLANTIC BEACH RIGHT-OF-WAY.ALL PROPOSED UNDERGROUND CATV WILL BEBURIED A MINIMUM OF 36" DEEP EXCEPT ROAD BORES60" DEEP AND DRIVEWAY BORES AT 60" DEEP.ALL PROPOSED UNDERGROUND CATV ROAD BORESWILL USE CITY APPROVED DIRECTIONAL BOREMACHINE, AS WELL AS COUNTY APPROVED CONDUIT.ALL PROPOSED CATV ROAD BORES WILL EXTEND AMINIMUM OF 9' BEYOND THE EDGE OF PAVEMENT.ALL PROPOSED CATV DRIVEWAY BORES WILL EXTENDA MINIMUM OF 6' BEYOND THE EDGE OF PAVEMENT.ALL PROPOSED BORES WILL BE IN A (4'X4'X4') PITAND WILL USE (2)2" HDPE CONDUIT AT 48" DEPTHUSING A 5 1/4" DRILL HEAD.ALL PROPOSED AERIAL WILL BE .700" DIAMETER ANDWILL BE LASHED TO .250" STEEL STRAND CABLEUSING .125" STANDARD GALVANIZED LASHING WIRE.ALL PROPOSED AERIAL CATV CROSSING ROADWAYSWILL HAVE MINIMUM MID-SPAN HEIGHT OF 9'-0"ALL PROPOSED AERIAL CATV CROSSING DRIVEWAYSWILL HAVE MINIMUM MID-SPAN HEIGHT OF 16'-0"LOCATES WILL BE REQUIRED IN ALL PROPOSEDUNDERGROUND AREAS AT LEAST 48 HRS PRIOR TOCONSTRUCTION.NOTIFICATIONS TO ALL UTILITIES INVOLVED WILL BEMADE PRIOR TO CONSTRUCTION.ALL DISTRIBUTED AREA WITHIN THE RIGHT OF WAYWILL BE RESTORED TO ORIGINAL OR BETTERCONDITION BY GRADING AND RE-SODDING. SOD ALLAREAS DISTURBED BY CONSTRUCTION WITHBERMUDA SOD. "ALL CRACKED SIDEWALK IS TO BEREPLACED FROM JOINT TO JOINT WITHIN 7 DAYS OFWORK COMPLETION."WORK OPERATIONS ARE TO BE MINDFUL NOT TODAMAGE THE PAVER SIDEWALK WHEN POSITIONINGEQUIPMENT. ANY DAMAGE INCLUDING TRACK MARKSWILL BE REPAIRED OR REPLACED BY THECONTRACTOR.CONSTRUCTION NOTESIN ORDER TO REDUCE THE DISRUPTION ANDCOST OF UTILITY DAMAGES OCCURRING INTHE RIGHT-OF-WAY AND EASEMENTS. THEPERMITTEE SHALL PREVENT DAMAGES TOEXISTING UTILITIES CAUSED BY THE WORKTHROUGH FIELD VERIFICATION OF THELOCATION OF THE EXISTING UTILITIES INCASE OF OPEN EXCAVATION. VERIFICATIONMAY BE PERFORMED DURING THEPERMITTEES WORK. IN THE CASE OFDIRECTIONAL DRILLING, VERIFICATION SHALLTAKE PLACE PRIOR TO MOBILIZATION OF THEDRILLING EQUIPMENT.THE PERMITTEE SHALL VERIFY THE LOCATIONOF THE EXISTING UTILITIES AS NEEDED TOAVOID CONTACT WITH DETECTIONEQUIPMENT OR OTHER ACCEPTABLE MEANS,SUCH METHODS MAY INCLUDE BUT SHALLNOT BE LIMITED TO-"SOFT DIG"-EQUIPMENTAND GROUND PENETRATION RADAR (GPR).THE EXCAVATOR SHALL BE HELD LIABLE FORDAMAGES CAUSED TO CITY'S/COUNTIES/STATE INFRASTRURE AND THE EXISTINGFACILITIES OF THE OTHER UTILITYCOMPANIESCOAXAAACONSTRUCTION NOTESCITY:SHEET NO:COUNTY:SCALE:STATE:DATE:DRAWN:NOT TO SCALE2 OF 8FLORIDAFIBER CORE GROUPPROPOSED UG CATV / FIBERFACILITIES IN DUVAL COUNTY, FLORIDADUVALATLANTIC BEACH09-25-2020
CITY OF ATLANTIC BEACHRIGHT-OF-WAYPERMITCOMCASTSTREET LIGHTPOWERCATVWATERSEWERPHONEPROPOSED AERIALCONCRETE POLEWOOD POLERISER POLEPEDESTALVAULTANCHORS/LS/LS/LEWATERSEWERCRVJOINT USAGE POLETRANSFORMER POLERIGHT OF WAYPROPOSED TRENCHPROPOSED BOREGASDBDBDBCULVERT4'X4'X4' BORE PITAAAEEGASGASPHONEPHONECATVCATV5' SIDEWALK30'301275255201278224982269084693203047633034033733131530928325980D\WD\WD\WD\WD\WD\WD\WD\WD\WD\WD\WD\WD\WD\WD\WD\WD\WD\WD\WD\WD\WD\WD\WD\WD\WD\WD\WD\WD\WD\WD\WD\WD\WEOT9' LANE9' LANEEOT10' LANE10' LANE18'9'9'36' FIBER 2' EOT AT&T 3' EOT FIBER 4' EOT SEWER 5' EOT CATV 6' EOT POWER POLE LINE 6' EOTEND PROJECTPROPOSED PED 6' EOTCATV / FIBER FACILITIESSTA: 00+30GPS COORDINATESN 30.325861W -81.397144BEGIN PROJECTEXISTING PED 6' EOTCATV / FIBER FACILITIESSTA:00+00GPS COORDINATESN 30.325871W -81.397048FIRST STAHERN STEAST COAST DRFIRST STAHERN ST9' LANE9' LANER\W305 AHERN ST, ATLANTIC BEACH, FL 322331 OF 1R\W5' SIDEWALK5' SIDEWALK WATER CENTER LINE9' LANE9' LANED\WOCEAN BLVDPLAN VIEWCITY:SHEET NO:COUNTY:SCALE:STATE:DATE:DRAWN:NOT TO SCALE3 OF 8FLORIDAFIBER CORE GROUPPROPOSED UG CATV / FIBERFACILITIES IN DUVAL COUNTY, FLORIDADUVALATLANTIC BEACH09-25-2020
CITY OF ATLANTIC BEACHRIGHT-OF-WAYPERMITCOMCASTSTREET LIGHTPOWERCATVWATERSEWERPHONEPROPOSED AERIALCONCRETE POLEWOOD POLERISER POLEPEDESTALVAULTANCHORS/LS/LS/LEWATERSEWERCRVJOINT USAGE POLETRANSFORMER POLERIGHT OF WAYPROPOSED TRENCHPROPOSED BOREGASDBDBDBCULVERT4'X4'X4' BORE PITAAAEEGASGASPHONEPHONECATVCATV36'18'18'9'9'9'9'EOT
EOT
CL
ROW ROW
ROW ROW
CL0''60"48"36"24"12"0''60"48"36"24"12"305 AHERN ST, ATLANTIC BEACH, FL 32233CROSS SECTION DETAILFOR EAST COAST DRSEWER 5' EOT
WATER CENTER LINE 5'SIDEWALK2'CATV 6' EOT
AT&T 3' EOT
FIBER 2' EOT
FIBER 4' EOT 3'4'5'6'CROSS SECTIONCITY:SHEET NO:COUNTY:SCALE:STATE:DATE:DRAWN:NOT TO SCALE4 OF 8FLORIDAFIBER CORE GROUPPROPOSED UG CATV / FIBERFACILITIES IN DUVAL COUNTY, FLORIDADUVALATLANTIC BEACH09-25-2020
CITY OF ATLANTIC BEACHRIGHT-OF-WAYPERMITCOMCASTSTREET LIGHTPOWERCATVWATERSEWERPHONEPROPOSED AERIALCONCRETE POLEWOOD POLERISER POLEPEDESTALVAULTANCHORS/LS/LS/LEWATERSEWERCRVJOINT USAGE POLETRANSFORMER POLERIGHT OF WAYPROPOSED TRENCHPROPOSED BOREGASDBDBDBCULVERT4'X4'X4' BORE PITAAAEEGASGASPHONEPHONECATVCATVEOT
CL
ROW ROW
ROW ROW
CL
0''60"48"36"24"12"0''60"48"36"24"12"RECIEVEPROPOSEDPEDSTA:00+3060" DEPTH(2) - 2" HDPE CONDUIT W/ 5 1/4" DRILL HEADENTRYEXISTING PEDSTA:00+0030'EOT
36'18'18'9'9'9'9'305 AHERN ST, ATLANTIC BEACH, FL 32233ROAD BORE DETAILFOR EAST COAST DRROAD BORE DETAILCITY:SHEET NO:COUNTY:SCALE:STATE:DATE:DRAWN:NOT TO SCALE5 OF 8FLORIDAFIBER CORE GROUPPROPOSED UG CATV / FIBERFACILITIES IN DUVAL COUNTY, FLORIDADUVALATLANTIC BEACH09-25-2020
CITY OF ATLANTIC BEACHRIGHT-OF-WAYPERMITCOMCASTSTREET LIGHTPOWERCATVWATERSEWERPHONEPROPOSED AERIALCONCRETE POLEWOOD POLERISER POLEPEDESTALVAULTANCHORS/LS/LS/LEWATERSEWERCRVJOINT USAGE POLETRANSFORMER POLERIGHT OF WAYPROPOSED TRENCHPROPOSED BOREGASDBDBDBCULVERT4'X4'X4' BORE PITAAAEEGASGASPHONEPHONECATVCATV40''24"30"28 3/4"[731]40 3/8"[1026]3"[75]35 1/2''[903]24"[610]Ground Level Box36"[914]Node CabinetPOWER & NODE TYPICALSCITY:SHEET NO:COUNTY:SCALE:STATE:DATE:DRAWN:NOT TO SCALE6 OF 8FLORIDAFIBER CORE GROUPPROPOSED UG CATV / FIBERFACILITIES IN DUVAL COUNTY, FLORIDADUVALATLANTIC BEACH09-25-2020
BTWO-LANE, TWO-WAYROADWORKAHEADACBUFFERSPACEWORK AREABUFFERSPACECBAROADWORKAHEADBUFFERSPACECBA BEPREPAREDTO STOPROADWORKAHEADWORK AREAMEDIANBUFFER SPACESpeed(mph)Dist.(ft.)253035404550556065155200250305360425495570645ROADWORKAHEADBACBUFFERSPACETCOTCOMULTILANESpeed(mph)DISTANCE BETWEEN SIGNSSpaceing (ft.)40 or less45ABC200350500200200350500350500SYMBOLSWork AreaTCOWork Zone SignFlaggerTraffic Control OfficerLane Identification + Direction of TrafficCONDITIONSGENERAL NOTES1.This Index does not apply to limited access facilities.2.When a side road intersects the highway within the TTC zone, additional ttc devicesshall be placed in accordance with applicable TCZ Indexes.3. Traffic volume or complexity of the roadway may dictate additional devices, signs,flagmen and/or a traffic control officer.4.The buffer space may be omitted if there are no sight obstructions to vehiclesapproaching the Flagger/Officer for distance equal to the buffer space.5.A Flagger may be substituted for a traffic control officer and the BE PREPARED TO STOP sign maybe omitted, when the following conditions are met:a. Speed limit is 45 mph or lessb. No sight obstructions to vehicles approaching the Flagger/Officer for a distance equal to the buffer space.c. vehicles in the work area have high-intenseity, roating, flashing, oscillating, or strobe lights operating.6.On undivided highways the median sign as shown are to be omitted.7.For general TCZ requirements and additional information refer to Index 102-600.PLANNED CLOSURE NOTEXCEEDING 5 MINUTES BEPREPAREDTO STOP50 or GreaterBEPREPAREDTO STOP BEPREPAREDTO STOPLASTREVISION11/01/17REVISION DESCRIPTION:FY 2020-21STANDARD PLANSINDEX102-625SHEET7 OF 8
CITY OF ATLANTIC BEACHRIGHT-OF-WAYPERMITCOMCASTSTREET LIGHTPOWERCATVWATERSEWERPHONEPROPOSED AERIALCONCRETE POLEWOOD POLERISER POLEPEDESTALVAULTANCHORS/LS/LS/LEWATERSEWERCRVJOINT USAGE POLETRANSFORMER POLERIGHT OF WAYPROPOSED TRENCHPROPOSED BOREGASDBDBDBCULVERT4'X4'X4' BORE PITAAAEEGASGASPHONEPHONECATVCATVTHE FOLLOWING STANDARD PLANSARE IN ACCORDANCE WITH THEFLORIDA DEPARTMENT OF TRANSPORTATION2020-2021 102-600 INDEX AND APPLY TO305 AHERN ST, ATLANTIC BEACH, FL 32233·STANDARD PLANS INDEX NO 102-625 ( TEMPORARY ROAD CLOSURE 5 MINUTES OR LESS )TRAFFIC CONTROL NOTESCITY:SHEET NO:COUNTY:SCALE:STATE:DATE:DRAWN:NOT TO SCALE8 OF 8FLORIDAFIBER CORE GROUPPROPOSED UG CATV / FIBERFACILITIES IN DUVAL COUNTY, FLORIDADUVALATLANTIC BEACH09-25-2020