1600 Mayport Rd SIGN21-0013 Lightbox, Sign Change MOBIL GASOWNER:ADDRESS:CITY:STATE:ZIP:
FIVE SISTERS TRUST PO BOX 100210 ROME GA 30162
COMPANY:ADDRESS:CITY:STATE:ZIP:
ALUMINUM PLUS dba RSR
Enterprises 750 E INTERNATIONAL SPDWY BLVD DELAND FL 32724
TYPE OF
CONSTRUCTION:
REAL ESTATE
NUMBER:ZONING:BUILDING USE
GROUP:SUBDIVISION:
172053 0020 SECTION LAND
JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK:
1600 MAYPORT RD SIGN WALL add lightbox & sign change
for MOBIL GAS $5000.00
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
BLDG 2ND PLAN REVIEW FEE 455-0000-322-1006 0 $50.00
SIGN WITH OR WITHOUT ELECTRIC 455-0000-322-1000 11.25 $65.00
SIGN WITH OR WITHOUT ELECTRIC 455-0000-322-1000 49.76 $245.00
STATE DBPR SURCHARGE 455-0000-208-0700 0 $6.38
STATE DCA SURCHARGE 455-0000-208-0600 0 $4.25
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN
YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT
MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU
INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT.
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
1 of 2Issued Date: 6/7/2021
PERMIT NUMBER
SIGN21-0013
ISSUED: 6/7/2021
EXPIRES: 12/4/2021
SIGN PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
ZONING WALL SIGN FEE 001-0000-329-1003 0 $30.00
TOTAL: $400.63
2 of 2Issued Date: 6/7/2021
PERMIT NUMBER
SIGN21-0013
ISSUED: 6/7/2021
EXPIRES: 12/4/2021
SIGN PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
DESCRIPTION ACCOUNT QTY PAID
PermitTRAK $465.63
SIGN21-0013 Address: 1600 MAYPORT RD APN: 172053 0020 $465.63
BLDG SUBSEQUENT PLAN REVIEW FEES $50.00
BLDG 2ND PLAN REVIEW FEE 455-0000-322-1006 0 $50.00
BUILDING $375.00
SIGN WITH OR WITHOUT ELECTRIC 455-0000-322-1000 11 $65.00
SIGN WITH OR WITHOUT ELECTRIC 455-0000-322-1000 50 $245.00
SIGN WITH OR WITHOUT ELECTRIC 455-0000-322-1000 11 $65.00
STATE SURCHARGES $10.63
STATE DBPR SURCHARGE 455-0000-208-0700 0 $6.38
STATE DCA SURCHARGE 455-0000-208-0600 0 $4.25
ZONING PLAN REVIEW $30.00
ZONING WALL SIGN FEE 001-0000-329-1003 0 $30.00
TOTAL FEES PAID BY RECEIPT: R16016 $465.63
Printed: Monday, June 7, 2021 9:53 AM
Date Paid: Monday, June 07, 2021
Paid By: ALUMINUM PLUS dba RSR Enterprises
Pay Method: CREDIT CARD 464976275
1 of 1
Cashier: CG
Cash Register Receipt
City of Atlantic Beach
Receipt Number
R16016
Final Plumbing
Final Electrical
Final HVAC
CC Final
Final Building*
Swimming Pool Steel
Swimming Pool Safety
Electrical Grounding & Bonding
Swimming Pool Final (Bldg)
Swimming Pool Final (PW)
Formed Columns/ Beams*
Masonry Cell Fill
Structural Steel*
OTHER:
OTHER:
OTHER:
OTHER:
OTHER:
Power Pole
Silt Fence
Piers/ Stem Walls
Underground Plumbing
Underground Electric
Foundation/ Footing
Slab**
Retaining Wall Footing
Driveway
Sewer (Building Dept)
Sewer Tap (Utilities Dept)
Rough Electric*
Rough Plumbing/ Top Out*
Rough Mechanical*
House Wrap
Wall Sheathing
Roof Sheathing
Tie-down Framing Connections
Rough Framing
Roofing In Progress
Window/Door In-Progress
Insulation Ceiling
Insulation Wall
Exterior Lath
Stucco Scratch Coat
Exterior Siding In-Progress
Brick Flashing & Ties
Early Power
Gas Rough
Gas Final*
* When all rough electric, plumbing, mechanical are complete but before any work is
covered up.
* When all gas piping is complete and wallboard is installed but before gas is
attached to any appliance. All outlets must be capped and pipe pressurized at a
minimum of 15 lbs.
* For new living space: When all construction work including electrical, plumbing,
mechanical, exterior finish, grading, required paving and landscaping is complete
and the building is ready for occupancy, but before being occupied
Additional inspections may apply to your project if your project
contains these elements:
INSPECTIONS REQUIRED FOR BUILDING PERMITS
To verify compliance with building codes, inspections of the work authorized are required at various points of the construction.
The following inspections are typically required for residential projects:
Date: Initial: Date: Initial:
_____________________________________________________
Permit Type
____________________________________________________
Permit No.
__________________________________________________________
Job Address
____________________________________________________
Contractor
POST THIS CARD WITH PERMITS AND PERMIT
DOCUMENTATION IN FRONT OF BUILDING
Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends
Building Department Public Works/Utilities Fire Department
Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789
Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203
* When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all
electrical, plumbing and mechanical work is in place, but before concrete is poured.
* When all structural steel members are in place and all connections are complete,
but before such work is covered or concealed.
** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION
PROPOSED FRONT CANOPY ELEVATION FACING EAST TOWARDS MAYPORT RD.
SCALE: N.T.S.
PROPOSED LEFT CANOPY ELEVATION FACING SOUTH
SCALE: N.T.S.
PROPOSED REAR CANOPY ELEVATION FACING C-STORE
SCALE: N.T.S.
PROPOSED RIGHT CANOPY ELEVATION FACING NORTH
SCALE: N.T.S.
CANOPY FASCIA AREA: 933.33 Sq. Ft.
SIGN AREA: 13.41 Sq. Ft.
CANOPY FASCIA AREA: 133.00 Sq. Ft.
SIGN AREA: 11.25 Sq. Ft.
CANOPY FASCIA AREA: 933.33 Sq. Ft.
SIGN AREA: 13.41 Sq. Ft.
FOR LOCATION ONLY
SCALE: 1 : 30
N
O
R
T
H
TH
I
S
I
T
E
M
H
A
S
B
E
E
N
E
L
E
C
T
R
O
N
I
C
A
L
L
Y
S
I
G
N
E
D
A
N
D
S
E
A
L
E
D
B
Y
M
I
C
H
A
E
L
J
.
W
O
J
T
U
N
I
A
K
,
P
.
E
.
O
N
_
_
_
_
_
_
_
U
S
I
N
G
A
S
.
H
.
A
.
A
U
T
H
E
N
T
I
C
A
T
I
O
N
C
O
DE
.
P
R
I
N
T
E
D
C
O
P
I
E
S
O
F
T
H
I
S
D
O
C
U
M
E
N
T
A
R
E
N
O
T
C
O
N
S
I
D
E
R
E
D
S
I
G
N
E
D
A
N
D
S
E
A
L
E
D
A
N
D
T
H
E
S
.
H
.
A
.
A
U
T
H
E
N
T
I
C
A
T
I
O
N
C
O
D
E
M
U
S
T
B
E
V
E
R
I
F
I
E
D
O
N
A
N
Y
E
L
E
C
T
R
O
N
I
C
CO
P
I
E
S
,
U
N
L
E
S
S
T
H
E
R
A
I
S
E
D
S
E
A
L
H
A
S
B
E
E
N
U
T
I
L
I
Z
E
D
.
MOBIL
PROPOSED DOWN LIGHTER (UL Listed)
SECTION 'A-A'
SCALE: N.T.S.
SECTION 'A-A'
SCALE: N.T.S.
Electrical Hookup
-Sign is UL Listed.
-Electrical requirements are 120 VAC 20A, with a connected load of less than 15 amps.
-This product is installed in a Class 1 Division 2 location per NEC 2017 chapter 500.
-All wiring must be installed per local code and NEC requirements.
-After installation of sign, electrician should run 16" whip through conduit nipple to J-Box
with switch and connected to primary electrical. (see Figure 2). Liquid tight conduit, J-Box
and switch to be provided by electrician.
-The NEC requires that a UL listed disconnect switch be installed and must be in straight
line-of-sight from the sign, after installation. This switch can be located directly behind the
canopy fascia and can control all signs on the same circuit that maintain the line-of-sight
requirement.
This structure has been designed in accordance with the requirements of the
Florida building code, 7th ED. (2020), chapter 16, structural loads, ASCE 7-2010
supplements & per N.E.C. 2017.
the following wind load requirements, in accordance with section 1609, were
employed in the design of the structure.
Basic wind speed: 150 mph, w/ 3-second gusts.
Building category: II
Wind exposure category: C
Design wind pressure for exterior components & cladding: (32.00 PSF)
4/27/21
Mobil Letter Area:
Squared Area - (22" x 73 5/8") 11.25 sq.ft.
Fret Cut ACM panel
#10 fender washer
Thermoformed Letterset
Secure to inside face of panel
with white silicon sealant
(Remove any excess sealant)
Bighead Fastener
Bond to inside face with
structural adhesive
#10-24 Nut
R 0.14”
Formed Letter Detail
2deg R 0.02”
1 1/2”
Exposed 0.118”
5/
8
”
TH
I
S
I
T
E
M
H
A
S
B
E
E
N
E
L
E
C
T
R
O
N
I
C
A
L
L
Y
S
I
G
N
E
D
A
N
D
S
E
A
L
E
D
B
Y
M
I
C
H
A
E
L
J
.
W
O
J
T
U
N
I
A
K
,
P
.
E
.
O
N
_
_
_
_
_
_
_
U
S
I
N
G
A
S
.
H
.
A
.
A
U
T
H
E
N
T
I
C
A
T
I
O
N
C
O
DE
.
P
R
I
N
T
E
D
C
O
P
I
E
S
O
F
T
H
I
S
D
O
C
U
M
E
N
T
A
R
E
N
O
T
C
O
N
S
I
D
E
R
E
D
S
I
G
N
E
D
A
N
D
S
E
A
L
E
D
A
N
D
T
H
E
S
.
H
.
A
.
A
U
T
H
E
N
T
I
C
A
T
I
O
N
C
O
D
E
M
U
S
T
B
E
V
E
R
I
F
I
E
D
O
N
A
N
Y
E
L
E
C
T
R
O
N
I
C
CO
P
I
E
S
,
U
N
L
E
S
S
T
H
E
R
A
I
S
E
D
S
E
A
L
H
A
S
B
E
E
N
U
T
I
L
I
Z
E
D
.
MOBIL
PROPOSED ILLUMINATED
LETTER BOX (UL LISTED)
SECTION 'A-A'
SCALE: N.T.S.
SECTION 'A-A'
SCALE: N.T.S.
Electrical Hookup
-Sign is UL Listed.
-Electrical requirements are 120 VAC 20A, with a connected load of less than 15 amps.
-This product is installed in a Class 1 Division 2 location per NEC 2017 chapter 500.
-All wiring must be installed per local code and NEC requirements.
-After installation of sign, electrician should run 16" whip through conduit nipple to J-Box
with switch and connected to primary electrical. (see Figure 2). Liquid tight conduit, J-Box
and switch to be provided by electrician.
-The NEC requires that a UL listed disconnect switch be installed and must be in straight
line-of-sight from the sign, after installation. This switch can be located directly behind the
canopy fascia and can control all signs on the same circuit that maintain the line-of-sight
requirement.
This structure has been designed in accordance with the requirements of the
Florida building code, 7th ED. (2020), chapter 16, structural loads, ASCE 7-2010
supplements & per N.E.C. 2017.
the following wind load requirements, in accordance with section 1609, were
employed in the design of the structure.
Basic wind speed: 150 mph, w/ 3-second gusts.
Building category: II
Wind exposure category: C
Design wind pressure for exterior components & cladding: (32.00 PSF)
4/27/21
COPY ATTACHMENT DETAIL
SCALE: N.T.S.
EXISTING SIGN AREA:
I.D. SIGN: 19.64 S.F.
TECHRON: 5.24 S.F.
PRICER: 19.64 S.F.
MART: 5.24 S.F.
TOTAL: 49.76 S.F.
PROPOSED SIGN AREA:
I.D. SIGN: 17.52 S.F.
REG/DSL: 24.89 S.F.
SYNERGY: 7.35 S.F.
TOTAL: 49.76 S.F.
TH
I
S
I
T
E
M
H
A
S
B
E
E
N
E
L
E
C
T
R
O
N
I
C
A
L
L
Y
S
I
G
N
E
D
A
N
D
S
E
A
L
E
D
B
Y
M
I
C
H
A
E
L
J
.
W
O
J
T
U
N
I
A
K
,
P
.
E
.
O
N
_
_
_
_
_
_
_
U
S
I
N
G
A
S
.
H
.
A
.
A
U
T
H
E
N
T
I
C
A
T
I
O
N
C
O
D
E
.
P
R
I
N
T
E
D
C
O
P
I
E
S
O
F
T
H
I
S
D
O
C
U
M
E
N
T
A
R
E
N
O
T
C
O
N
S
I
D
E
R
E
D
S
I
G
N
E
D
A
N
D
S
E
A
L
E
D
A
N
D
T
H
E
S
.
H
.
A
.
A
U
T
H
E
N
T
I
C
A
T
I
O
N
C
O
D
E
M
U
S
T
B
E
V
E
R
I
F
I
E
D
O
N
A
N
Y
E
L
E
C
T
R
O
N
I
C
CO
P
I
E
S
,
U
N
L
E
S
S
T
H
E
R
A
I
S
E
D
S
E
A
L
H
A
S
B
E
E
N
U
T
I
L
I
Z
E
D
.
I.D. SIGN
PROPOSED I.D. SIGN FACE
CHANGE ONLY (UL LISTED)
Electrical Hookup
-Sign is UL Listed.
-Electrical requirements are 120 VAC 20A, with a connected load of less than 15 amps.
-This product is installed in a Class 1 Division 2 location per NEC 2017 chapter 500.
-All wiring must be installed per local code and NEC requirements.
-After installation of sign, electrician should run 16" whip through conduit nipple to J-Box
with switch and connected to primary electrical. (see Figure 2). Liquid tight conduit, J-Box
and switch to be provided by electrician.
-The NEC requires that a UL listed disconnect switch be installed and must be in straight
line-of-sight from the sign, after installation. This switch can be located directly behind the
canopy fascia and can control all signs on the same circuit that maintain the line-of-sight
requirement.
This structure has been designed in accordance with the requirements of the
Florida building code, 7th ED. (2020), chapter 16, structural loads, ASCE 7-2010
supplements & per N.E.C. 2017.
the following wind load requirements, in accordance with section 1609, were
employed in the design of the structure.
Basic wind speed: 150 mph, w/ 3-second gusts.
Building category: II
Wind exposure category: C
Design wind pressure for exterior components & cladding: (32.00 PSF)
5/25/21