Loading...
1600 Mayport Rd SIGN21-0013 Lightbox, Sign Change MOBIL GASOWNER:ADDRESS:CITY:STATE:ZIP: FIVE SISTERS TRUST PO BOX 100210 ROME GA 30162 COMPANY:ADDRESS:CITY:STATE:ZIP: ALUMINUM PLUS dba RSR Enterprises 750 E INTERNATIONAL SPDWY BLVD DELAND FL 32724 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 172053 0020 SECTION LAND JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 1600 MAYPORT RD SIGN WALL add lightbox & sign change for MOBIL GAS $5000.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BLDG 2ND PLAN REVIEW FEE 455-0000-322-1006 0 $50.00 SIGN WITH OR WITHOUT ELECTRIC 455-0000-322-1000 11.25 $65.00 SIGN WITH OR WITHOUT ELECTRIC 455-0000-322-1000 49.76 $245.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $6.38 STATE DCA SURCHARGE 455-0000-208-0600 0 $4.25 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 6/7/2021 PERMIT NUMBER SIGN21-0013 ISSUED: 6/7/2021 EXPIRES: 12/4/2021 SIGN PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 ZONING WALL SIGN FEE 001-0000-329-1003 0 $30.00 TOTAL: $400.63 2 of 2Issued Date: 6/7/2021 PERMIT NUMBER SIGN21-0013 ISSUED: 6/7/2021 EXPIRES: 12/4/2021 SIGN PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 DESCRIPTION ACCOUNT QTY PAID PermitTRAK $465.63 SIGN21-0013 Address: 1600 MAYPORT RD APN: 172053 0020 $465.63 BLDG SUBSEQUENT PLAN REVIEW FEES $50.00 BLDG 2ND PLAN REVIEW FEE 455-0000-322-1006 0 $50.00 BUILDING $375.00 SIGN WITH OR WITHOUT ELECTRIC 455-0000-322-1000 11 $65.00 SIGN WITH OR WITHOUT ELECTRIC 455-0000-322-1000 50 $245.00 SIGN WITH OR WITHOUT ELECTRIC 455-0000-322-1000 11 $65.00 STATE SURCHARGES $10.63 STATE DBPR SURCHARGE 455-0000-208-0700 0 $6.38 STATE DCA SURCHARGE 455-0000-208-0600 0 $4.25 ZONING PLAN REVIEW $30.00 ZONING WALL SIGN FEE 001-0000-329-1003 0 $30.00 TOTAL FEES PAID BY RECEIPT: R16016 $465.63 Printed: Monday, June 7, 2021 9:53 AM Date Paid: Monday, June 07, 2021 Paid By: ALUMINUM PLUS dba RSR Enterprises Pay Method: CREDIT CARD 464976275 1 of 1 Cashier: CG Cash Register Receipt City of Atlantic Beach Receipt Number R16016 Final Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: _____________________________________________________ Permit Type ____________________________________________________ Permit No. __________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION PROPOSED FRONT CANOPY ELEVATION FACING EAST TOWARDS MAYPORT RD. SCALE: N.T.S. PROPOSED LEFT CANOPY ELEVATION FACING SOUTH SCALE: N.T.S. PROPOSED REAR CANOPY ELEVATION FACING C-STORE SCALE: N.T.S. PROPOSED RIGHT CANOPY ELEVATION FACING NORTH SCALE: N.T.S. CANOPY FASCIA AREA: 933.33 Sq. Ft. SIGN AREA: 13.41 Sq. Ft.                                                                                                                                                              CANOPY FASCIA AREA: 133.00 Sq. Ft. SIGN AREA: 11.25 Sq. Ft. CANOPY FASCIA AREA: 933.33 Sq. Ft. SIGN AREA: 13.41 Sq. Ft. FOR LOCATION ONLY SCALE: 1 : 30 N O R T H                                                                                                                                                              TH I S I T E M H A S B E E N E L E C T R O N I C A L L Y S I G N E D A N D S E A L E D B Y M I C H A E L J . W O J T U N I A K , P . E . O N _ _ _ _ _ _ _ U S I N G A S . H . A . A U T H E N T I C A T I O N C O DE . P R I N T E D C O P I E S O F T H I S D O C U M E N T A R E N O T C O N S I D E R E D S I G N E D A N D S E A L E D A N D T H E S . H . A . A U T H E N T I C A T I O N C O D E M U S T B E V E R I F I E D O N A N Y E L E C T R O N I C CO P I E S , U N L E S S T H E R A I S E D S E A L H A S B E E N U T I L I Z E D . MOBIL PROPOSED DOWN LIGHTER (UL Listed) SECTION 'A-A' SCALE: N.T.S. SECTION 'A-A' SCALE: N.T.S. Electrical Hookup -Sign is UL Listed. -Electrical requirements are 120 VAC 20A, with a connected load of less than 15 amps. -This product is installed in a Class 1 Division 2 location per NEC 2017 chapter 500. -All wiring must be installed per local code and NEC requirements. -After installation of sign, electrician should run 16" whip through conduit nipple to J-Box with switch and connected to primary electrical. (see Figure 2). Liquid tight conduit, J-Box and switch to be provided by electrician. -The NEC requires that a UL listed disconnect switch be installed and must be in straight line-of-sight from the sign, after installation. This switch can be located directly behind the canopy fascia and can control all signs on the same circuit that maintain the line-of-sight requirement. This structure has been designed in accordance with the requirements of the Florida building code, 7th ED. (2020), chapter 16, structural loads, ASCE 7-2010 supplements & per N.E.C. 2017. the following wind load requirements, in accordance with section 1609, were employed in the design of the structure. Basic wind speed: 150 mph, w/ 3-second gusts. Building category: II Wind exposure category: C Design wind pressure for exterior components & cladding: (32.00 PSF) 4/27/21 Mobil Letter Area: Squared Area - (22" x 73 5/8") 11.25 sq.ft. Fret Cut ACM panel #10 fender washer Thermoformed Letterset Secure to inside face of panel with white silicon sealant (Remove any excess sealant) Bighead Fastener Bond to inside face with structural adhesive #10-24 Nut R 0.14” Formed Letter Detail 2deg R 0.02” 1 1/2” Exposed 0.118” 5/ 8 ” TH I S I T E M H A S B E E N E L E C T R O N I C A L L Y S I G N E D A N D S E A L E D B Y M I C H A E L J . W O J T U N I A K , P . E . O N _ _ _ _ _ _ _ U S I N G A S . H . A . A U T H E N T I C A T I O N C O DE . P R I N T E D C O P I E S O F T H I S D O C U M E N T A R E N O T C O N S I D E R E D S I G N E D A N D S E A L E D A N D T H E S . H . A . A U T H E N T I C A T I O N C O D E M U S T B E V E R I F I E D O N A N Y E L E C T R O N I C CO P I E S , U N L E S S T H E R A I S E D S E A L H A S B E E N U T I L I Z E D . MOBIL PROPOSED ILLUMINATED LETTER BOX (UL LISTED) SECTION 'A-A' SCALE: N.T.S. SECTION 'A-A' SCALE: N.T.S. Electrical Hookup -Sign is UL Listed. -Electrical requirements are 120 VAC 20A, with a connected load of less than 15 amps. -This product is installed in a Class 1 Division 2 location per NEC 2017 chapter 500. -All wiring must be installed per local code and NEC requirements. -After installation of sign, electrician should run 16" whip through conduit nipple to J-Box with switch and connected to primary electrical. (see Figure 2). Liquid tight conduit, J-Box and switch to be provided by electrician. -The NEC requires that a UL listed disconnect switch be installed and must be in straight line-of-sight from the sign, after installation. This switch can be located directly behind the canopy fascia and can control all signs on the same circuit that maintain the line-of-sight requirement. This structure has been designed in accordance with the requirements of the Florida building code, 7th ED. (2020), chapter 16, structural loads, ASCE 7-2010 supplements & per N.E.C. 2017. the following wind load requirements, in accordance with section 1609, were employed in the design of the structure. Basic wind speed: 150 mph, w/ 3-second gusts. Building category: II Wind exposure category: C Design wind pressure for exterior components & cladding: (32.00 PSF) 4/27/21 COPY ATTACHMENT DETAIL SCALE: N.T.S. EXISTING SIGN AREA: I.D. SIGN: 19.64 S.F. TECHRON: 5.24 S.F. PRICER: 19.64 S.F. MART: 5.24 S.F. TOTAL: 49.76 S.F. PROPOSED SIGN AREA: I.D. SIGN: 17.52 S.F. REG/DSL: 24.89 S.F. SYNERGY: 7.35 S.F. TOTAL: 49.76 S.F. TH I S I T E M H A S B E E N E L E C T R O N I C A L L Y S I G N E D A N D S E A L E D B Y M I C H A E L J . W O J T U N I A K , P . E . O N _ _ _ _ _ _ _ U S I N G A S . H . A . A U T H E N T I C A T I O N C O D E . P R I N T E D C O P I E S O F T H I S D O C U M E N T A R E N O T C O N S I D E R E D S I G N E D A N D S E A L E D A N D T H E S . H . A . A U T H E N T I C A T I O N C O D E M U S T B E V E R I F I E D O N A N Y E L E C T R O N I C CO P I E S , U N L E S S T H E R A I S E D S E A L H A S B E E N U T I L I Z E D . I.D. SIGN PROPOSED I.D. SIGN FACE CHANGE ONLY (UL LISTED) Electrical Hookup -Sign is UL Listed. -Electrical requirements are 120 VAC 20A, with a connected load of less than 15 amps. -This product is installed in a Class 1 Division 2 location per NEC 2017 chapter 500. -All wiring must be installed per local code and NEC requirements. -After installation of sign, electrician should run 16" whip through conduit nipple to J-Box with switch and connected to primary electrical. (see Figure 2). Liquid tight conduit, J-Box and switch to be provided by electrician. -The NEC requires that a UL listed disconnect switch be installed and must be in straight line-of-sight from the sign, after installation. This switch can be located directly behind the canopy fascia and can control all signs on the same circuit that maintain the line-of-sight requirement. This structure has been designed in accordance with the requirements of the Florida building code, 7th ED. (2020), chapter 16, structural loads, ASCE 7-2010 supplements & per N.E.C. 2017. the following wind load requirements, in accordance with section 1609, were employed in the design of the structure. Basic wind speed: 150 mph, w/ 3-second gusts. Building category: II Wind exposure category: C Design wind pressure for exterior components & cladding: (32.00 PSF) 5/25/21