64 Jackson Rd ROOF21-0036 Metal RoofOWNER:ADDRESS:CITY:STATE:ZIP: SEXTON, FALON and BRENDAN 204 9th STREET SOUTH JACKSONVILLE BEACH FL 32250 COMPANY:ADDRESS:CITY:STATE:ZIP: HAMMER TIME ROOFING 14286 Beach Blvd JACKSONVILLE FL 32250 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 172041 0000 SECTION LAND JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 64 JACKSON RD ROOF NON SHINGLE SHINGLE AND METAL ROOF $9200.00 FEES LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 BUILDING ROOF IN-PROGRESS INSPECTION REQUIRED INFORMATIONAL Notes: a. The roof sheathing for all new construction must remain uncovered until the Roof Sheathing Inspection is approved. b. All roofing projects require an In-Progress Inspection. c. Sheathing installation and replacement guidelines per APA. d. Underlayment must conform to FBC-R Table 905.1.1 e. Shingles must conform to ASTM D3161 G or H, or ASTM D7158 F NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 6/7/2021 PERMIT NUMBER ROOF21-0036 ISSUED: 6/7/2021 EXPIRES: 12/4/2021 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $100.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $50.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.25 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $154.25 2 of 2Issued Date: 6/7/2021 PERMIT NUMBER ROOF21-0036 ISSUED: 6/7/2021 EXPIRES: 12/4/2021 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 DESCRIPTION ACCOUNT QTY PAID PermitTRAK $154.25 ROOF21-0036 Address: 64 JACKSON RD APN: 172041 0000 $154.25 BUILDING $100.00 BUILDING PERMIT 455-0000-322-1000 0 $100.00 BUILDING PLAN REVIEW $50.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $50.00 STATE SURCHARGES $4.25 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.25 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL FEES PAID BY RECEIPT: R16021 $154.25 Printed: Monday, June 7, 2021 1:30 PM Date Paid: Monday, June 07, 2021 Paid By: HAMMER TIME ROOFING Pay Method: CREDIT CARD 464962428 1 of 1 Cashier: CG Cash Register Receipt City of Atlantic Beach Receipt Number R16021 Final Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: _____________________________________________________ Permit Type ____________________________________________________ Permit No. __________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION BUILDING PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Road, Atlantic Beach FL 32233 Office: (904)247-5826 ° Fax: (904) 247-5845 Job Address: (;lf , hd:-.'>Q/"\ Rd Permit Number: _______ _ Legal Description 17-.:J '::, •r q f .; n /JT C-r<'hJ7 u,t ~ Kao r./t~ dlil, -RE# 17 }.o4 1 -Olg) • .j. s-'1 Valuation of Work (Replacement Cost) $ a. · Heated/Cooled SF ____ Non-Heated/Cooled ____ _ ° Class of Work (Circle one): New Addition Alteration Repair Move Demo Pool Window/Door 0 Use of existing/proposed structure(s) (Circle one): Commercial ~ 0 If an existing structure, is a fire sprinkler system installed? (Circle one): Yes No <E1]S:) □ Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in det ail the tYPe of work to be performed: /C.(...-J(ll.:; S I • / Ill\~\ f rol\ + ~of-htr, t.,, !fic:•c.A. Florida Product Approval # ____ ... ~...,.,: _ ___.d ___ .... @.....,c .._/2e ....... :e.,./4~2 ... c1 __ ~ _____ for multiple products use product approval fonn Property Owner Information Name: R~rlc.tq J_sz-ln-1 Address: aot.t j /!i sf. S. ~ City ~~--:JJic. 11,..;:( Statep ~JliCLPhoneM~~? g7J-J :?a~ E-Mail flsexk .., (! wfvcn 16,, et,dQ.. ~~-5cm -, ~j · y)_f-1 Owner or Agent (If Agent, Power of Attorney or Agency Letter Required,L_ ________________________ _ Contractor Information: Name of Company 61,,,.,:-r:: Ia: HP:oi+ Qualifying Agen~ o., 11,,"' & k-. ,.,,,.) Address: l'11YG tb.-r -:1 A{Ed. _2k.. I~ 3£~ City \-K & ~ State' Zip F(. ? a \-0 Office Phone (9CJ:U 716 5 J'1C, Job Site/Contact Number ffj)L( L a.1/o ~ ~ ~--P::1 State Certification/Registration# CCC i 11 'i'i r 3 E-Mail br;,;, .. c );.,.,;;rQJ f G :£<"> 4, / ta.A--,_ Architect Name & Phone #---------------------------------Engineer's Name & Phone# ___________________________________ _ Worker's Compensation Exempt / Insurer / Lease Employees 7 Exp1rat1on Date A pplication is hereby made to obtain a pennit to do che work and installatio11s as indicated. I certify that no work or installation has commenced f!!Wr to the issuance of a pennic and that all work will be pe1fo11ned to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null and void if work is not commencea within six (6) months, or if constmction or work is susJ]_ended or abandoned for a Qeriod of six (6) months ac any time after work is commenced. I understand that separate pem1its must be secure · Electrical W.. rk, Plumbi11g, Signs, Wells, Pools, Furnaces, Boilers, Heaters, Tan/cs and Air Co1Zditio11ers, etc. • ROOF21-0036 "' --.J (;) "' -0 ll) co Cl) tlOTICE OF OOMMENCEMENT ?:;mU Ne. _______________ _ Sra~ of F/0 , ... , J, Tex Fann Ne . / ! I oY I -(«O County of D•4 v,_ T!l whom l t may ccncsrn : n,s uncierEign ed here!:l~r informs you th;;t improvamsnts will be made to eertaln re2I proper1'/, and in Eccordsnce with Sectio n 7'i3 of foe Florida Staiutss. tire followina information Is stated in this NOTICE OF COMMENCEM~NT. . - !..ega i d~CiijjOCfl of prcpsrty b:ing il!il)i.:i1!;ti: I 7 ·~ s -5 c 1 ?-1 er (-:(, ,7 lA a, 1<,::ro qb , ;3 Z:,&:: a r:'1 i=ee Slmp!: Tiilehcldeqlfoths r then owns q _____________________________ _ Mant e _____________________________________________ _ Phona No. __________________ ~=X Ne. ____________________ _ N ::m; and :ddra:s of :ny pei:on m:kifi~f.Jo=:n fQ; the constr.,ucj::,n ~ the improvements. Name · ,".O'J::S~ -------------------------------------------Plion; Ne. __________________ ~a >: 1"'-l o. ____________________ _ Name---------------------------------------------- Addres;; -------------------------------------------Phone Mo. __________________ :=:s:-: No. ____________________ _ In addition t.l i;lmss lf. ownar design;:tes tlie follov!liig p:;raon to r:eeiva a ecpy of the Lienor's Nol!ce as provlcisci Ir. Section 713.06 (2 i (bi. Flcrida s: .. tures. tRli in :rt o·.-mer's option). Neme ____________________________________________ _ Address ------------------------------------------- Phom, Mo. ________________ !=!!x No. _____________________ _ Expiration oat;; of Motice oi Commsncsmsm (rh& expfration dais is one (1 j ysar from the data of recording unless e diff::rsnt das Is spscifiect J: ---------------------------- THIS SP.rl.CE: FOP. ?-ECORDeR'S !JSE ONLY -~~;fv:~~-.. FRANK .M. BR ENNAN }··· ~ ·:.~~\ MY COMMIS SION_# GG 287369 ~~-~:.;,.: EXPIRES : Apnl 28 , 2023 ·--~~~~¥,/~~~>· Bonded Thru No tary Pu blic Und erwrilers ;,;:;:1~,y ?.:!:!i i; ly ;em;r.ZuJ ~=:a:;;t!i}" ;(, ?io.!u~ I~:nL ~:..:;;,;;:.~;:;,:_::::_~:,::,i:::iil';i:.::::::::::::::::-__ ROOF21-0036 PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH, FLORIDA (*REQUIRED ) I *Project Addres s: G 4 )~c..k:Suf'\ R..c Perm it#: __________ _ *Owner/Project Name: ---"-'--"''---"'-'n'--'-------------------------------------- As requ i red by Florida Statut e 553 .842 and Florida Admin istrative Code Ru le 9B-72 , please provide the infor mation and product approval number(s) for the building components listed below as applicable to the building const r uction project fo r the permit number li sted above . You should contact you r product supplier if you do not know the product approval number for any of the applicable listed products. Information regard i ng statewide product approval may be obtained at: www.floridabuilding.org. category/Subcategory Manufacturer Product Description Limitation of Use State# Local# A. EXTERIOR DOORS 1. Swinging 2. Sli d in g 3. Sectional 4 . Garage Roll-Up 5. Automatic 6. Other B.WINDOWS 1. Single hung 2. Horizontal slider 3. Casement 4. Double hung 5. Fixed 6.Awn ing 7. Pass -through 8. Projected 9 . Mullion 10. Wind breaker 11 . Dual action 12 . Other Page 1 of 4 Updated 10/17/18 ROOF21-0036 Category /Subcategory Manufacturer Product Description Limitation of Use State# Local# C. PANEL WALL 1. Sid i ng 2. Soffit s 3. EIFS 4 . Sto refronts 5 . Curtain wall s 6 . Wall louvers 7. Glass block 8. Membrane 9. Greenhouse 10. Synthetic stucco 11. Other D. ROOFING PRODUCTS 1. Asphalt shingles 0-,ue'"' ~ Lc)(,-H /'IC A~t+-Sh,r-c: L,.:;-tu0-l-/ ;o<o 7'-/-l!.13 2. Underlayments ,1,,J -c::.,~ks _J "y(.{ • AJ!vred 1:f(j2(kJ.1. ~ ~1.-t /74o/-£l/ 3. Roofing fasteners I 4. Nonstructural meta l (nefv 1~ iwhAc ~G)f roof rn,/lr 1111,u.rl) !he/o.l 5~ (/.\-I< 8 5 . Bu ilt-up roofing -' 6 . Modified bitumen 7. Single ply roofing 8. Roofing tiles 9. Roofing insulation 10. Waterproofing 11. Wood sh i ngles/shakes 12. Roofing slate 13. Liquid applied roofing 14. Cement-adhes ive coats 15. Roof tile adhesive 16. Spray appl ied polyurethane roof 17. Other Page 2 of 4 Upd ated 10/17/18 In addition to completing the above list of manufacturers, product description and State approval number for the products used on this project, the Contractor shall maintain on the job site and available to the Inspector, a legible copy of each manufacturer's printed specifications and installation instructions along with this Product Approval Sheet. I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the ones listed in this document must be approved by the Building Official. *Contractor Name ( Print Na me): A11-f.A ,>/\/ & Ji; n. UJ U (i *Company Name: _/-h..............,IV7.-"-'-l()U........_f _Tr~1~~---'--'-£e____._...c...u..ft..._~-=+--L--'LC=---=--------------------- *Mailing Address: __ / Li~'J_cf'_G_/~fQ~'C_;,,,_1?._1/vt_t[_<;~f _/~1-__ s_n _______________ _ *City: c4---tlao fr C &o ob. ;::-t_ *Telephone Number: ( 10 1.-/J ]/&-9 1'-(9 *State : -~h_L _____ *Zip Code: __ 5._;)_~_ro~~------- Cell Phone Number: Fax Number: ----------------------------------------- Page 4 of 4 Updated 10/17 /18 PREMIUM ROOF REPORT ADDRESS 64 Jackson Rd, Atlantic Beach, FL, US Table Of Contents Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Cover Page Draw ing Edge & Facet Identification Area Diagram Length Diagram Pitch Diagram Prepared on : May 26th , 2021 Prepared by : Hammer T ime Roofing 'us tel : Email : hammertimeroof@gmail.com This report was generated by roofgraf.com , GRA-roofgraf.com , \ i I and subject to Sofdesk s terms of service . ' support@roofgraf.com Copyright Sofdesk Inc. ROOF21-0036 Edge & Facet Identification ,, ~. ·· ~ ~::~zr;~~;-_:_-~ ·~, ~. Ridge • Hip • Valley Penetration 64 Jackson Rd , Atlantic Beach, FL, US 0s;· ,S' , .. ___ 71,... 7'1" 9 '8" 7 '1 0~ 38' 4 " - 53.58 21.00 6.67 0 -6'8" s· 1 · ------- 11' 4" 8' 7'4"_J3' 7" - 38' S " 38' 8 " ·-· Rake • 49.25 Eave • 109.42 Apron Flashing • 4 .67 Step Flashing • 0.00 r ~ • ·1 ~ , This report is for estimation purposes only . Please make sure to verify all roof details, obstacles, slopes, dimensions prior to material ordering . f f This report was generated by roofgraf.com , • r -GRA-roo gra .com , \ :-r f f and subject to Sofdesk's terms of service . support@roo gra .com Copyright Sofdesk Inc. ROOF21-0036 FL#: FL 5211.3-RS Date: 10 / 11 / 2020 CBUCK E:nc;alnPEYlnQ Report No.: 20 -22 4-M-S GW -ER Page 2 of 7 ~ ~truc:tu'dl E:nQlne:aE"rlnQ CBUCK, Inc. Certificate af Authorization #8064 Manufacturer: Product Name: Product Category: Product Sub-Category Compliance Method: Product/System Description: Product Assembly as Evaluated: Support: Slope: Performance: Millennium Metals, Inc. "M-Seam" Roofing Metal Roofing State Product Approval Rule 61G20-3.005 (1) (d) "M-Seam " 26 gauge Minimum, Steel roof panel mechanically attached to Plywood Deck with screws . Refer to Page 4 of this report for product assembly components/materials & standards: 1. Roof Panel 2. Fasteners 3. Underlayment 4. Insulation (Optional) Type: Wood Deck (Design of support and its attachment to support framing is outside the scope of this evaluation.) Description: • 15/32 (min.) or 19/32" or greater plywood, • or Wood plank (min . specific gravity of 0.42) Minimum slope shall be in compliance with FBC Chapter 15 Section 1507.4.2, applicable code sections and in accordance with manufacturer's recommendations. Wind Uplift Resistance: • Design Uplift Pressure: Refer to Table "A" (Refer to "Table A" attachment details herein) FL#: FL 5211.3-RS Date: 10 / 11 / 2020 CBUCK E:nQlnr?CYlnQ Report No.: 20-224-M-S6W -ER Page 3 of 7 !:,pecldlh.J !:,truc:h.xdl E::nQlr,e,erlnQ CBUCK, Inc. Certificate of Authorization #8064 Performance Standards: The product described herein has demonstrated compliance with : Standards Equivalency: Code Compliance: Evaluation Report Scope: Limitations and Conditions of Use: . Quality Assurance: • U L580-06 -Test for Uplift Resistance of Roof Assemblies • UL 1897-12-Uplift test for roof covering systems • The UL 580 -94 standard version used to test the evaluated product assembly is equivalent to UL580-06 standard version adopted by the Florida Building Code 7th Edition (2020). • The UL 1897-98 standard version used to test the evaluated product assembly is equivalent to UL1897-12 standard version adopted by the Florida Building Code 7th Edition (2020). The product described herein has demonstrated compliance with the performance standards listed above as referenced in the Florida Building Code 7th Edition (2020). This product evaluation is limited to compliance with the structural requirements of the Florida Building Code , as related to the scope section to Florida Product Approval Rule 61620-3.001. • Scope of "Limitations and Conditions of Use" for this evaluation : This evaluation report for "Optional Statewide Approval" contains technical documentation , specifications and installation method(s) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 61620- 3.005. Per Rule 61620-3.004, the Florida Building Commission is the authority to approve products under "Optional Statewide Approval". • Option for application outside "Limitations and Conditions of Use" Rule 61620-3 .005(1)(e) allows engineering analysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. • This report is a building code product evaluation per FLPE rule (FAC) 61615-36 to comply with Florida product approval rule (FAC) 61620-3 . This evaluation report is part of the Florida Building Commission approval for the listed code related criteria . This report by James Buckner, P.E. and CBUCK Engineering is not a design certification of code compliance construction submittal documentation, per FBC section 107, for any individual structure, site specific or permit design. • All metal components and fasteners shall be corrosion resistant in accordance with applicable sections of FBC, including but limited to Sections 1504.3.2, 1506.6 and 1507.4.4. • Design of support system is outside the scope of this report. • Fire Classification is outside the scope of Rule 61620-3, and is therefore not i ncluded in this evaluation. • This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section . (Dade & Broward Counties) The manufacturer has demonstrated compliance of roof panel products in accordance with the Florida Building Code and Rule 61620-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certifications, Inc . (FBC Organization#: QUA 1824). FL#: FL 5211.3-RS Date : 10 / 11 / 2020 CBUCK E:nQlnf?EYlnQ Report No.: 20-224 -M-S6W -ER Page 4 of 7 !::,pecldlh.J !::.truc:turdl E:nQlnA?rlnQ CBUCK, Inc . Certificate of Authorization #8064 Components/Materials (by Manufacturer): Components/Materials (by Others): Roof Panel: Product Identification : Material: Thickness: Panel Width: Rib Height: Yield Strength : Corrosion Resistance: Fastener: Type : Size : Penetration Through : Corrosion Resistance : Standard: Underlayment: M -Seam Steel 26 gauge Minimum 16" (max.) Coverage 1" 40 ksi min . In compliance with FBC Section 1507.4.3 : • ASTM A792 coated, or • ASTM A653 G90 galvanized steel Pancake -Head Wood Screw #10 (x length to meet min . penetration through deck) 3/16" min. through wood deck Per FBC Section 1506.6 and 1507.4.4 Per ANSI/ASME 818.6 .4 Material and application shall be in compliance with FBC Section 1507.1.1 and in accordance with applicable code sections and manufacturer's recommendations . Insulation (Optional): Type : Thickness : Properties: Density : Or Compressive Strength : Insulation Notes: Rigid Insulation Board 3" (max.) 2.25 pcf (lbs/ft3) min. 20 psi min . • Rigid Insulation shall meet m inimum density OR compressive strength. • Insulation shall comply with FBC Section 1508 . When insulation is incorporated, fastener length shall conform to penetrate thru bottom of support a minimum of 3/16". FL#: Fl 5211.3-RS Date: 10/11/2020 CBUCK E:nQlneerlnQ Report No.: 20-224 -M-SGW -ER Page 5 of 7 ~dlh.J !:,truc::t"LXdl E:nQlnE"E"rlnQ CBUCK, Inc. Certificate of Authoriz ation 118064 Installation: Referenced Data: Installation Method: (Refer to drawings on Pages 6-7 of this report .) • Fastener spacing : Refer to Table "A" Below (along the length of the panel) • Rib Interlock: Snap Lock (Panel ribs shall be fully engaged to form an integral interlock.) • Minimum fastener penetration thru bottom of support, 3/16". • For panel construction at the end of panels, refer to manufacturer's instructions and any site specific design. TABLE "A" ALLOWABLE LOADS METHOD 1: METHOD 2: * Design Pressure: -84.25 PSF -91.75 PSF Deck Thickness : 15/32" or 19/32" 15/32" or 19/32" Fastener Spacing : 8 " 4" * Allowable design pressure for allowable stress design (ASD) with a margin of safety of 2 to 1. Install the "M-Seam " roof panel assembly in compliance with the installation method listed in this report and applicable code sections of FBC 7th Edition (2020). The installat ion method described herein is in accordance with the scope of this evaluation report. Refer to manufacturer's installation i nstructions as a supplemental guide for attachment. 1. UL580-94 & UL 1897-98 Uplift Test By Hurricane Test Laboratory, LLC (FBC Organization #TST ID : 1527) Report#: 0232 -0508-05, Report Date: 6/29/05, Specimens #1-3 2. Quality Assurance By Keystone Certifications, Inc . (QUA ID : 1824) Millennium Metals Licensee# 423 3. Equivalency ofTest Standard Certification By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization# ANE 1916) 4. Certification of Independence By James L. Buckner, P.E .@ CBUCK Engineering (FBC Organization# ANE 1916) FL#: FL 5211.3-RS Date : 10 / 11 / 2020 CBUCK E:nQlnPEYlnQ Report No .: 20 -224-M-S6W -ER Page 6 of 7 ~ ~truc::h..-dl E:nQlnE?A"lnQ CBUCK, Inc. Certificate of Authorization #8064 Installation Method Millennium Metals "M-Seam" Roof Panel Attached to Wood Deck Profile Drawings j_i------1-- ~ ll -I J_ _____ __;:,(\._ __ ~_ ~ l. 16'' ~ Typical Panel Profile View (Not To Scale) 16''0.C. ·lntegal Snap Lod< ____ #10 Pcnc:ake-Head Screw · 3116'' nin. penetratioo ttru deck Typical Assembly Profile View (Not To Scale) FL#: FL 5211.3-RB Date: 10/11/2020 CBUCK E:nc;,lnPEYlnQ Report No.: 20-224-M-S6W -ER Page 7 of 7 Installation Method Millennium Metals CBUCK, Inc. Certificate of Authorization #8064 "M-Seam" Roof Panel Attached to Wood Deck Fastener: #10 Parca<e-t-m:J :--cTF----- .awn: -15/'5.2' er 1~'52' CDX AyMm [a::k, er lnsuciim: ·(Q:xicml) 'J' rrax er 25 r:s rrin. -V\txxl perk Typical Assembly Profile View (Not To Scale) TABLE "A" ALLOWABLE LOADS METHOD 1: METHOD 2: * Design Pressure: -84.25 PSF -91.75 PSF Deck Thickness : 15/32" or 19/32" 15/32" or 19/32" Fastener Spacing : 8" 4" * Allowable design pressure for allowable stress design (ASD) with a margin of safety of 2 to 1. MILLENNIUM METALS, INC . 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 904-358-8366 WATTS 1-877-357-7663 (ROOF) FAX 904-358-8285 Net Coverage 1 6" Nomina l PANEL PROFILE Sidelap Detail Nailstrip Detail NOTES: 1. M-Seam Panels are only available with minor ribs to reduce oil canning. 2. Oil canning is inherent to all metal panels and therefore is not considered a manufacturers defect nor a warranty condition. 3. Consult your contractor immediately if you need information concering this condition. DIMPLE APROX . EVERY 4 " O.C. STARTER/ENO SLOT APROX. 2 " FROM PANEL ENDS Gauge Finishes Nominal Thickness ASTM & Grade Specifications 26 Acrylic Galvalume .0179 26 PTO Galvalume * .0179 24 Acrylic Galvalume .0240 • PTO Galvalume is 70% Kynar 500 or Hylar 5000 PVDF Resin unless otherwise indicated . Millennium Metals Offers a Limited 25 year warranty on Painted Panels , 20 year limited warranty on Mill Finished Acrylume Panels. Please request warranty Information from your distributor. MILLENNIUM METALS INC. TOLL FREE: 1-877-358-7663 FAX: 904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 ASTM A-792 AZ55 ASTM A-792 AZ55 ASTM A-792 AZ55 PAGE 1 MILLENNIUM METALS , INC .. 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 904-358 -8366 WATTS 1 -877-357-7663 (ROOF) FAX 904-358 -8285 M-Seam Installation Instructions: Panel Attachment: M-Seam recommended attachment is 8" on center along the edge of the nailer strip. This attachment may not be suitable for all applications. Projects may require an engineer to evaluate conditions such as mean height, exposure type, and roof configuration as indicated in ASCE 7-98 and ASCE 7-02 . Additional fasteners may be required along the end zones on the panel (eave , ridge, and perimeter). Pitch Alert: This product should not be used on applications less than a 2/12 pitch. Roof Application: Step 1: Make sure deck is even and square . Step 2: Panel should begin on the gable end opposite of the prevailing wind. Begin with the receiving edge of panel (female side) along the Gable (see Gable Rake Detail). The edge away from the Gable should be the nailstrip. After checking that the panel is square to the eave, make sure the panel is attached as indicated in panel attachment (see above) and also 2" from the leading and trailing end o f the panel on the nailstrip . The screw should be placed in the center of the nailstrip slot provided. Sealant is recommended on applications less than a 3/12 pitch. Step 3 : After attaching the first panel completely, panel 2 should be snapped in place using a rubber mallet. A minimum of l" overhang is recommended at the eave. Typical eave detail requires the use of a hemming tool to hem the panel over the ED2 ( detail has 1-1/2" overhang). Install the remaining accessories . Millennium Metals offers a variety of products such as pipe boots , butyl tape , and ventilation materials. Do not use copper or lead products in conjunction with M-Seam as it will void the warranty. ATTENTION INSTALLER : PLEASE REFER TO THE IMPORTANT NOTE SECTION OF THIS MANUAL FOR SAFETY, STORAGE, OIL CANNING DISCLAIMER, AND SHAVING DISCLAIMER PRIOR TO BEGINNING PROJECT. Code requirements vary from area to area and job type as well as roof configuration. Job specific engineering is not a service prov ided by Millennium Metals. Estimates/Takeoft's are provided at a nominal fee for materials only. It is the sole responsibility of the customer to review the takeoff and make any changes to the quantity , length or accessories h e/she feels necessary. Millennium Metals takes no responsibility as to the accuracy of the information provided. M-Seam is a special order product and therefore is not returnable . Please verify all items prior to ordering. MILLENNIUM METALS INC. TOLL FREE: 1 -877 -358 -7663 FAX : 904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6 /04 PAGE 2 Important Notes: MILLENNIUM METALS, INC. 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 904-358 -8366 WATTS 1 -877-357-7663 (ROOF) FAX 904-358-8285 Millennium Metals recommends licensed roofing professionals to install our materials . Please use gloves , glasses , and other protection when handling material to prevent injury . It is necessary to inspect deck integrity to insure it is safe to walk on before beginning any work. Millennium Metals recommends all installers follow the OSHA requirement for fall protection. Never walk on materials when wet or when unsuitable weather conditions are present. Storage: Materials should be installed immediately. Any unused materials should be stored in a dry place where moisture will not reach and penetrate bundles. Material should always be placed on wood block to separate from the ground or concrete . Do not cover with plastic!!! In stead , use loose canvas tarps so that air can circulate. Cut the bands so that the material can expand. Millennium Metals warrants the material only. We do not offer weather tightness warranties. Any such warranty is up to the contractor to include in their contract. Decking: Millennium Metals recommends the use of minimum ½" plywood or OSB Board attached in accordance with code. The deck must be supported by an engineered truss system not to exceed 24" on center. A moisture barrier such as 30# felt or other ASTM approved underlayment should be used over decking to control moisture. Metal should never come in direct contact with green or pressure treated lumber as it will cause corrosion. If tin tabs are required to attach felt it will be necessary to apply a 15# felt in the direction of the panel as an additional separation barrier. M-seam is recommended on application with 2-1/2 I 12 or greater. Oil Canning Disclaimer: Oil canning is industry wide and inherit to all metal panels. It is more visible in designs with flat spans as with this panel. Oil canning is a wavy appearance in the surface of the metal panel. This slight distortion in no way effects the warranty nor is a reason for rejection or refusal. Shavings Disclaimer: When using fasteners to penetrate steel sheets the iron particles tend to go airborne and settle on the sheet. It is necessary to remove these particles to prevent embedment and rust marks. MILLENNIUM METALS INC. TOLL FREE: 1-877 -358 -7663 FAX : 904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE 3 en C ~ m C) ~ ~ 0 C) ::c ~ C) m ::E ...., ~ ::c 0 C ~ :z 0 ~ ...., C) m HS-1 HIGH-SIDE EAVE PAGE? MILLENNIUM METALS, INC . 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 904 -358-8366 WATTS 1 -877 -357-7663 (ROOF) FAX 904 -358-8285 EW-3 ENDWALL PAGE 11 SW-3 SW-4 SIDEWALL PAGE 10 SW-4 or SW-3 SIDEWALL PAGE10 RC-10 RC-15 RIDGE PAGE6 M-SEAM DETAIL LOCATIONS RC-10 HIP PAGE6 SR-1 GR-9 RAKE EDGE PAGES PANEL PROFILE PAGE 1 ED-2 EAVE DRIP PAGE? TF-2 TRANSITION PAGE9 1 EAVE DRIP (EF-5) ~/PAINT ll'St·· 1/2-Q 4. GABLE RAKE (GR-9) 3-1/8" ~ - 5/a"S ,.!, X)/2" 5/8")y 7. HIP CAP (RC-10) ~ ~-3/8" 11 TRANSITION FLASHING (TF 2) 15. RIDGE CAP (BC-20) * 1 3/8" FLASHING PROFILES MILLENNIUM METALS INC. TOLL FREE: 1-877-358-7663 FAX: 904-358-8285 MILLENNIUM METALS, INC. 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 904-358-8366 WATTS 1-877-357-7663 (ROOF) FAX 904-358-8285 2. ENDWALL FtASHING (EW-3} /PAINT ~ItSs 1/2-1;;1- 4 GABLE RAKE (GR-9Rl 3-1/4" I I ~0 5/8': .,~4 5/8'~ 8. J-CHANNEL (JC-7) 4-1 /2" 1 2. SIDEWALL FLASHING (SW-3) 3 EXTENDED EAVE (ED-2) ~PAINT ,~r 1,;2· ( 1/2"11~5/8" OVERHANG: 1-t 5. GAMBREL FLASHING (GF -2) 9 . PREFORMED VALLEY (PV-3) 13. STEP RAKE (SR-1 ) 3" 1" nu-N -I+ :::- 1 / 2" ,), ~ 5/8" 1/2>s<. 3 EXTENDED EAVE CED-2Rl ~PSNT ~11/2" 5/8;,x OVERHANG: 1 -t 6 HIGHSIDE EAVE (HS-J) 10 STEP SIDEWALL (SW-4) 14 COUNTER FLASHING (CF -1) OFFSET CLEAT CCL-2) Z-CLOSURE (ZC-1 l REGLET FLASHING /RF -1 l 1/2" SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 1" ++ 7_-,-+ 4-'=+ 1]~ PAGE 5 RIDGE CAP MILLENNIUM METALS, INC. 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 904-358 -8366 WATTS 1 -877 -357-7663 (ROOF) FAX 904-358 -8285 STITCH SCREWS 0 12" O.C., DO NOT OVERDRIVE M-SEAM PANEL VENTING MATERIAL 7JILllll_lllLllff& 30/1 FELT ATTACHED PER CODE APPROVED SOLID SUBSTRATE VENTED RIDGE DETAIL RC-15 RIDGE CAP RC-1 0/RC-20 S.S. POP RIVETS •z• CLOSURE CUT TO FIT BETWEEN PANEL, (3) /110-12 X 1" PANCAKE HEAD SCREWS PER PANEL CONT . BUTYL TAPE SEALANT APPROVED SOLID SUBSTRATE /130 FELT ATTACHED PER CODE HIP /RIDGE FLASHING MILLENNIUM METALS INC. TOLL FREE: 1 -877-358-7663 FAX : 904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE 6 #10-12 X 1" PANCAKE HEAD SCREWS O 12" O.C. M-SEAM PANEL /130 FELT ATTACHED PER CODE APPROVED SOLID SUBSTRATE CLEAT W/ /110-12 X 1• MILLENNIUM METALS, INC. 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 904 -358 -8366 WATTS 1 -877 -357 -7663 (ROOF) FAX 904 -358 -8285 M-SEAM HEMMED PANCAKE HEAD SCREW C 12" O.C. / FASCIA BOARD_/ SEE DETAIL FOR HEMMING PANEL PAGE 3 EAVE DRIP DETAIL ED-2 EAVE FLASHING PANEL SHOWN SHORT TO DEPICT M-SEAM PANEL l!J_;z___~ APPROVED SOLID 7 SUBSTRATE #30 FELT ATTACHED PER CODE CLEAT W/ /110-12 X 1" PANCAKE HEAD SCREWS O 12" O.C. ~---CONT.BUTYL TAPE SEALANT HIGHSIDE EAVE DETAIL HS-1 MILLENNIUM METALS INC. TOLL FREE: 1 -877 -358 -7663 FAX :904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6 /04 DETAIL. MAKE IT FLUSH AND MAKE HOLE. PAGE 7 START MILLENNIUM METALS, INC. 10200 EASTPORT ROAD JACKSONV I LLE , FL 32218 904 -358 -8366 WATTS 1 -87 7-35 7-7663 (ROOF ) FAX 904 -358 -8285 30# FELT ATTACHED PER CODE 12· o.c. CONT. BUTYL TAPE SEALANT STEP GABLE FLASHING APPROVED SOLID SUBSTRATE ~--FASCIA STEP GABLE RAKE DETAIL SR-1 CLEAT W/#10-12 X 1• PANCAKE HEAD SCREWS 30# FELT ATTACHED PER CODE APPROVED SOLID SUBSTRATE M-SEAM PANEL END FlaD BEND PANEL 1 • MIN . CONT. BUTYL TAPE SEAIANT STITCH SCREWS 0 12· o.c. END FJELD BEND PANEL 1 • MIN . CONT . sum TAPE SEALANT "Z" CLOSURE STITCH SCREWS 0 12· o.c . "Z" CLOSURE CUT TO FlT BETWEEN PANEL. (3) #12 X 1 WHS PER PANEL START GABLE RAKE DETAIL GR-9 CONT. sum TAPE SEALANT FASCIA CLEAT W/ #10-12 X 1• PANCAKE HEAD SCREWS MILLENNIUM METALS INC. TOLL FREE: 1 -877 -358-7663 FAX : 904-358-8285 SUBJECT TO CHANGE WITHOU T NOTICE 10/6 /04 PAGE 8 MILLENNIUM METALS, INC. 10200 EASTPORT ROAO JACKSONVILLE, FL 32218 904-358-8366 WATTS 1-877-357-7663 (ROOF) FAX 904-358-8285 VALLEY FLASHING CLEAT SET IN BUTYL TAPE SEALANT W/ #10-12 X 1" PANCAKE HEAD SCREWS 6" O.C. APPROVED SOLID SUBSTRATE CONT. BUTYL TAPE SEALANT PREFORMED VALLEY DETAIL PV-3 OFFSET CLEAT SET IN BUTYL TAPE SEALANT W/ #10-12 X 1" PANCAKE HEAD SCREWS O 12" O.C. CONT . BUTYL TAPE SEALANT 7." CLOSURE CUT TO FIT BETWEEN PANEL. (3) #10-12 X 1" PANCAKE SCREWS PER PANEL TRANSITION DETAIL MILLENNIUM METALS INC. TOLL FREE: 1-877-358-7663 FAX:904-358-8285 • ~--TRANSITION FLASHING ___ S.S . POP RIVETS 0 12· o.c. SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 -SEAM PANEL f FELT ATTACHED PER CODE APPROVED SOLID SUBSTRATE PANEL PAGE 9 SEALANT CONT. STEP SIDEWALL FLASHING #30 FELT ATTACHED PER CODE APPROVED SOLID SUBSTRATE STITCH SCREWS 0 12" o.c. CONT. BUTYL TAPE SEALANT M-SEAM PANEL MILLENNIUM METALS, INC. 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 904-358 -8366 WATTS 1 -877-357-7663 (ROOF) FAX 904-358-8285 SEALANT CONT . BUTYL TAPE SEALANT SURFACE-MOUNT COUNTER FLASHING SIDEWALL FLASHING S.S. POP RIVET @ 12" o.c. "z" CLOSURE CUT TO FIT BETWEEN PANEL, (3) #12 X 1 PANCAKE SCREWS PER PANEL CONT . BUTYL TAPE SEALANT #30 FELT .::.,_, ,.,_ ATTACHED PER CODE ~.;_: APPROVED SOLID SUBSTRATE M-SEAM PANEL SIDEWALL FLASHING DETAIL SW-3 & SW-4 SEALANT REGLET FLASHING SAW CUT MASONARY WALL STEP SEALANT----- CONT. BUTYL--+---.tP,QI TAPE SEALANT CONT . BUTYL TAPE SEALANT SIDEWALL FLASHING SIDEWALL COUNTER FLASHING OPTIONS MILLENNIUM METALS INC. TOLL FREE: 1 -877 -358 -7663 FAX :904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE 10 SEALANT CONT . BUTYL TAPE SEALANT SURFACE MOUNT COUNTER FLASHING HEADWALL FLASHING CONT . BUTYL TAPE SEALANT "Z" CLOSURE CUT TO FIT BETWEEN PANEL, (3) # 10-12 X 1" PANCAKE HEAD SCREWS PER PANEL S.S . POP RIVETS M-SEAM PANEL MILLENNIUM METALS, INC . 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 904-358 -8366 WATTS 1 -877 -357 -7663 (ROOF) FAX 904-358 -8285 APPROVED SOLID SUBSTRATE ======~~~ #30 FELT ATTACHED PER CODE ENDWALL DETAIL EW-3 SEALANT REGLET FLASHING SAW CUT MASONARY WALL STEP SEALANT CONT . BUTYL TAPE SEALANT CONT . BUTYL TAPE SEALANT SIDEWALL FLASHING ENDWALL COUNTER FLASHING OPTIONS MILLENNIUM METALS INC. TOLL FREE: 1-877 -358 -7663 FAX : 904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6 /04 PAGE 11 CAULK MILLENNIUM METALS, INC. 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 904 -358 -8366 WATTS 1 -877-357 -7663 (ROOF) FAX 904-358-8285 PANEL HEMMING CUT PANEL BACK 1 r TO CREATE HEM . USE HEMMING TOOL. MILLENNIUM METALS INC. TOLL FREE: 1-877-358-7663 FAX : 904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10 /6/04 PAGE 12 Proposal HAMMER ROOFING , LLC. IME 14286 Beach Blvd Ste 19-386 CCC1329983 Phone: 904.716.9149 Email: Hammertimeroof®amail.com Name Phone Date Brendan Sexton 5-5-2021 Street City, State 64 Jackson Rd Atlantic Beach, Fl 32233 Email Fax falonsexton@gmail.com Roof Type: Compostion Shingles We hereby submit specifications and estimate for: Remove and replace shingles with : Color: Customer Choice Manufacturer: Owens Coming (Duration) Type: Limited Lifetime architectural Eave Drip Color: Customer Choice *[nspect and replace any rotted decking(if any) Nail decking off to proper wind mitigation code using 8d ring shank nails. Install new 6" galvanized eave metal to perimeter of roof. ( x) Peel and stick Ice and Water Shield. ( x ) Lead Plumbing Boots l " _l _2" _I _3 " ( x) Off Ridge Vents 4' ----''--6' ( ) Install Cobra ventilation upgrade ( ) Dryer Vent ( ) Kitchen Vent Install new ridge cap shingles to all hips and ridges. Clean up and removal of all debris. Magnetize perimeter of job site . Includes permit and dumpster Shingles to entire roof including front-$7,700 Shingles to main and Metal Roof Front-$9,200 Miscellaneous Comments: Rafter tails-This will be priced per tail. Cut back bad ones back to wall. Scab new tail to existing. $200 per tail. Material and Labor( Additional) Metal Roof to Front Area- Galvalume painted standing seam metal roof. I inch seam . * Any rotted wood discovered (if any) will incur an additional charge as follow: Plywood per 4x8 sheet:$ 110.00 ¾ plywood Linear Wood : $9.00 per foot Ice and water shield to entire roof sheathing additional -~ln=c~lu=d~ed~---~ We hereby propose to furnish labor and material-complete in accordance with the above specifications, for the sum of. --~N=in=e~T=ho~u=s=a=n=d~Tw~o~H=u=n=d~red~D~o=lla=r=s ____ ($ 9,200 ) -~$~4=0~0~0 _______ Deposit -~$=5-=,2,..,0-=-0 _____ Balance on Completion All material is guaranteed to be as specified. A ll work is to be completed in a workmanlike manner according to standard practices. Any alteration or deviation from the above specifications involving extra costs will be executed upon written and or verbal order from appropriate managing authority and will become an extra charge over and above the estimate. We can take rain gutters down that are attached to eave metal(one story onl y/ additional charge for 2 and 3 story houses) and place th em to the s id e but we w ill not be responsibl e for re-installation. We will not take down any super gutters that are located on back scree ned in porches. Gutter/Screen Enclosure company will need to be contacted. Not responsible for damage to driveway that may occur during material delivery/roll off container placement. We wi ll not be liab le for flat tires to lawn mowers, car tires and injury from nails that could occur due to roofing construction demolition an d replacement. We cannot guarantee every nail that is removed will be picked up with the magnet but we will do a thorough clean up upon completion . We w ill not be held responsible for replacement of any pictures/decorations that could possib ly fal l or come loose during delivery of material or during roofing installation. Not responsible for roof leaks in areas other than those worked on. Under no circum stances is Hammer Time Roofing LLC responsible for existing damages to building, its contents or roof deck. All agreements contingent upon strikes, accident or de lays beyond our control. Owner to carry Fire, Tornado and other necessary insurance. This pro posal subject to acceptance within 30 days and it is void thereafter at the option of the unders igned. Invoices not paid in full within 30 days will incur a 2.0% per month charge until paid in full. Authorized Signa tu re: Anthon y Betancour t 5-19-2021 ACCEPTANCE O F PROPSAL The above prices, specifications and conditions are hereby accepted . You are authorized to do the work as s pecified. Payment will be made as outlined above. Signature: _______ _ Signature: ______ _ Date of acceptance: ______ _ GUARANTEE:_5_ year(s) roof leak free repair under normal weather conditions from completion date. The warranty shall protect the owner from damage to the building and contents resulting from the leakage for a period of (5) year(s) beginning from the date of completion of the project. The warranty shall cove r and include repair or replacement of any damaged exterior structure, interior structure, interior components and contents of the building, resulting from roof leakage directly attributed to the contractor 's workmanship. ~CCORDING TO FLORIDA 'S CONSTRUCTION LIEN LAW (SECTIONS 713.001 -713.37. FLORIDA STATUTES), THOSE WHO WORK ON YOUR PROPERTY OR PROVIDE MATERIALS AND SERVICES AND ARE NOT PAID IN FULL HAVE A RIGHT TO ENFORCE THEIR CLAIM FOR PAYMENT AGAINST YOUR PROPERTY . THIS CLAIM IS KNOWN AS A CONSTRUCTION LIEN . IF YOUR CONTRACTOR OR A SUBCONTRACTOR FAILS TO PAY SUBCONTRACTORS, SUB- SUBCONTRACTORS, OR MATERIAL SUPPLIERS, THOSE PEOPLE WHO ARE OWED MONEY MAY LOOK TO YOUR PROPERTY FOR PAYMENT, EVEN IF YOU HAVE ALREADY PAID YOUR CONTRACTOR IN FULL. IF YOU FAIL TO PAY YOUR CONTRACTOR. YOUR CONTRACTOR MAY ALSO HAVE A LIEN ON YOUR PROPERTY . THIS MEANS IF A LIEN IS FILED YOUR PROPERTY COULD BE SOLD AGAINST YOUR WILL TO PAY FOR LABOR, MATERIALS, OR OTHER SERVICES THAT YOUR CONTRACTOR OR A SUBCONTRACTOR MAY HAVE FAILED TO PAY . TO PROTECT YOURSELF, YOU SHOULD STIPULATE IN THIS CONTRACT THAT BEFORE ANY PAYMENT IS MADE, YOUR CONTRACTOR IS REQUIRED TO PROVIDE YOU WITH A WRITTEN RELEASE OF LIEN FROM ANY PERSON OR COMPANY THAT HAS PROVIDED TO YOU A "NOTICE TO OWNER." FLORIDA'S CONSTRUCTION LIEN LAW IS COMPLEX, AND IT IS RECOMMENDED THAT YOU CONSULT AN ATTORNEY .