64 Jackson Rd ROOF21-0036 Metal RoofOWNER:ADDRESS:CITY:STATE:ZIP:
SEXTON, FALON and
BRENDAN 204 9th STREET SOUTH JACKSONVILLE
BEACH FL 32250
COMPANY:ADDRESS:CITY:STATE:ZIP:
HAMMER TIME ROOFING 14286 Beach Blvd JACKSONVILLE FL 32250
TYPE OF
CONSTRUCTION:
REAL ESTATE
NUMBER:ZONING:BUILDING USE
GROUP:SUBDIVISION:
172041 0000 SECTION LAND
JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK:
64 JACKSON RD ROOF NON SHINGLE SHINGLE AND METAL ROOF $9200.00
FEES
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
1 BUILDING ROOF IN-PROGRESS INSPECTION REQUIRED INFORMATIONAL
Notes:
a. The roof sheathing for all new construction must remain uncovered until the Roof Sheathing Inspection is approved.
b. All roofing projects require an In-Progress Inspection.
c. Sheathing installation and replacement guidelines per APA.
d. Underlayment must conform to FBC-R Table 905.1.1
e. Shingles must conform to ASTM D3161 G or H, or ASTM D7158 F
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN
YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT
MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU
INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT.
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
1 of 2Issued Date: 6/7/2021
PERMIT NUMBER
ROOF21-0036
ISSUED: 6/7/2021
EXPIRES: 12/4/2021
ROOF NON SHINGLE PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
BUILDING PERMIT 455-0000-322-1000 0 $100.00
BUILDING PLAN CHECK 455-0000-322-1001 0 $50.00
STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.25
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00
TOTAL: $154.25
2 of 2Issued Date: 6/7/2021
PERMIT NUMBER
ROOF21-0036
ISSUED: 6/7/2021
EXPIRES: 12/4/2021
ROOF NON SHINGLE PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
DESCRIPTION ACCOUNT QTY PAID
PermitTRAK $154.25
ROOF21-0036 Address: 64 JACKSON RD APN: 172041 0000 $154.25
BUILDING $100.00
BUILDING PERMIT 455-0000-322-1000 0 $100.00
BUILDING PLAN REVIEW $50.00
BUILDING PLAN CHECK 455-0000-322-1001 0 $50.00
STATE SURCHARGES $4.25
STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.25
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00
TOTAL FEES PAID BY RECEIPT: R16021 $154.25
Printed: Monday, June 7, 2021 1:30 PM
Date Paid: Monday, June 07, 2021
Paid By: HAMMER TIME ROOFING
Pay Method: CREDIT CARD 464962428
1 of 1
Cashier: CG
Cash Register Receipt
City of Atlantic Beach
Receipt Number
R16021
Final Plumbing
Final Electrical
Final HVAC
CC Final
Final Building*
Swimming Pool Steel
Swimming Pool Safety
Electrical Grounding & Bonding
Swimming Pool Final (Bldg)
Swimming Pool Final (PW)
Formed Columns/ Beams*
Masonry Cell Fill
Structural Steel*
OTHER:
OTHER:
OTHER:
OTHER:
OTHER:
Power Pole
Silt Fence
Piers/ Stem Walls
Underground Plumbing
Underground Electric
Foundation/ Footing
Slab**
Retaining Wall Footing
Driveway
Sewer (Building Dept)
Sewer Tap (Utilities Dept)
Rough Electric*
Rough Plumbing/ Top Out*
Rough Mechanical*
House Wrap
Wall Sheathing
Roof Sheathing
Tie-down Framing Connections
Rough Framing
Roofing In Progress
Window/Door In-Progress
Insulation Ceiling
Insulation Wall
Exterior Lath
Stucco Scratch Coat
Exterior Siding In-Progress
Brick Flashing & Ties
Early Power
Gas Rough
Gas Final*
* When all rough electric, plumbing, mechanical are complete but before any work is
covered up.
* When all gas piping is complete and wallboard is installed but before gas is
attached to any appliance. All outlets must be capped and pipe pressurized at a
minimum of 15 lbs.
* For new living space: When all construction work including electrical, plumbing,
mechanical, exterior finish, grading, required paving and landscaping is complete
and the building is ready for occupancy, but before being occupied
Additional inspections may apply to your project if your project
contains these elements:
INSPECTIONS REQUIRED FOR BUILDING PERMITS
To verify compliance with building codes, inspections of the work authorized are required at various points of the construction.
The following inspections are typically required for residential projects:
Date: Initial: Date: Initial:
_____________________________________________________
Permit Type
____________________________________________________
Permit No.
__________________________________________________________
Job Address
____________________________________________________
Contractor
POST THIS CARD WITH PERMITS AND PERMIT
DOCUMENTATION IN FRONT OF BUILDING
Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends
Building Department Public Works/Utilities Fire Department
Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789
Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203
* When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all
electrical, plumbing and mechanical work is in place, but before concrete is poured.
* When all structural steel members are in place and all connections are complete,
but before such work is covered or concealed.
** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION
BUILDING PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Road, Atlantic Beach FL 32233
Office: (904)247-5826 ° Fax: (904) 247-5845
Job Address: (;lf , hd:-.'>Q/"\ Rd Permit Number: _______ _
Legal Description 17-.:J '::, •r q f .; n /JT C-r<'hJ7 u,t ~ Kao r./t~ dlil, -RE# 17 }.o4 1 -Olg)
• .j. s-'1
Valuation of Work (Replacement Cost) $ a. · Heated/Cooled SF ____ Non-Heated/Cooled ____ _
° Class of Work (Circle one): New Addition Alteration Repair Move Demo Pool Window/Door
0 Use of existing/proposed structure(s) (Circle one): Commercial ~
0 If an existing structure, is a fire sprinkler system installed? (Circle one): Yes No <E1]S:)
□ Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal
Describe in det ail the tYPe of work to be performed: /C.(...-J(ll.:;
S I • / Ill\~\ f rol\ + ~of-htr, t.,, !fic:•c.A.
Florida Product Approval # ____ ... ~...,.,: _ ___.d ___ .... @.....,c .._/2e ....... :e.,./4~2 ... c1 __ ~ _____ for multiple products use product approval fonn
Property Owner Information
Name: R~rlc.tq J_sz-ln-1 Address: aot.t j /!i sf. S. ~
City ~~--:JJic. 11,..;:( Statep ~JliCLPhoneM~~? g7J-J :?a~
E-Mail flsexk .., (! wfvcn 16,, et,dQ.. ~~-5cm -, ~j · y)_f-1
Owner or Agent (If Agent, Power of Attorney or Agency Letter Required,L_ ________________________ _
Contractor Information:
Name of Company 61,,,.,:-r:: Ia: HP:oi+ Qualifying Agen~ o., 11,,"' & k-. ,.,,,.)
Address: l'11YG tb.-r -:1 A{Ed. _2k.. I~ 3£~ City \-K & ~ State' Zip F(. ? a \-0
Office Phone (9CJ:U 716 5 J'1C, Job Site/Contact Number ffj)L( L a.1/o ~ ~ ~--P::1
State Certification/Registration# CCC i 11 'i'i r 3 E-Mail br;,;, .. c );.,.,;;rQJ f G :£<"> 4, / ta.A--,_
Architect Name & Phone #---------------------------------Engineer's Name & Phone# ___________________________________ _
Worker's Compensation
Exempt / Insurer / Lease Employees 7 Exp1rat1on Date
A pplication is hereby made to obtain a pennit to do che work and installatio11s as indicated. I certify that no work or installation has commenced
f!!Wr to the issuance of a pennic and that all work will be pe1fo11ned to meet the standards of all laws regulating construction in this jurisdiction.
This permit becomes null and void if work is not commencea within six (6) months, or if constmction or work is susJ]_ended or abandoned for a
Qeriod of six (6) months ac any time after work is commenced. I understand that separate pem1its must be secure · Electrical W.. rk, Plumbi11g,
Signs, Wells, Pools, Furnaces, Boilers, Heaters, Tan/cs and Air Co1Zditio11ers, etc. •
ROOF21-0036
"' --.J
(;)
"' -0
ll)
co
Cl)
tlOTICE OF OOMMENCEMENT
?:;mU Ne. _______________ _
Sra~ of F/0 , ... , J, Tex Fann Ne . / ! I oY I -(«O
County of D•4 v,_
T!l whom l t may ccncsrn :
n,s uncierEign ed here!:l~r informs you th;;t improvamsnts will be made to eertaln re2I proper1'/, and in
Eccordsnce with Sectio n 7'i3 of foe Florida Staiutss. tire followina information Is stated in this NOTICE OF
COMMENCEM~NT. . -
!..ega i d~CiijjOCfl of prcpsrty b:ing il!il)i.:i1!;ti: I 7 ·~ s -5 c 1 ?-1 er (-:(, ,7 lA a,
1<,::ro qb , ;3 Z:,&:: a r:'1
i=ee Slmp!: Tiilehcldeqlfoths r then owns q _____________________________ _
Mant e _____________________________________________ _
Phona No. __________________ ~=X Ne. ____________________ _
N ::m; and :ddra:s of :ny pei:on m:kifi~f.Jo=:n fQ; the constr.,ucj::,n ~ the improvements.
Name ·
,".O'J::S~ -------------------------------------------Plion; Ne. __________________ ~a >: 1"'-l o. ____________________ _
Name----------------------------------------------
Addres;; -------------------------------------------Phone Mo. __________________ :=:s:-: No. ____________________ _
In addition t.l i;lmss lf. ownar design;:tes tlie follov!liig p:;raon to r:eeiva a ecpy of the Lienor's Nol!ce as provlcisci Ir.
Section 713.06 (2 i (bi. Flcrida s: .. tures. tRli in :rt o·.-mer's option).
Neme ____________________________________________ _
Address -------------------------------------------
Phom, Mo. ________________ !=!!x No. _____________________ _
Expiration oat;; of Motice oi Commsncsmsm (rh& expfration dais is one (1 j ysar from the data of recording unless e
diff::rsnt das Is spscifiect J: ----------------------------
THIS SP.rl.CE: FOP. ?-ECORDeR'S !JSE ONLY
-~~;fv:~~-.. FRANK .M. BR ENNAN
}··· ~ ·:.~~\ MY COMMIS SION_# GG 287369
~~-~:.;,.: EXPIRES : Apnl 28 , 2023
·--~~~~¥,/~~~>· Bonded Thru No tary Pu blic Und erwrilers
;,;:;:1~,y ?.:!:!i
i; ly ;em;r.ZuJ
~=:a:;;t!i}" ;(,
?io.!u~ I~:nL ~:..:;;,;;:.~;:;,:_::::_~:,::,i:::iil';i:.::::::::::::::::-__
ROOF21-0036
PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH, FLORIDA (*REQUIRED )
I
*Project Addres s: G 4 )~c..k:Suf'\ R..c Perm it#: __________ _
*Owner/Project Name: ---"-'--"''---"'-'n'--'--------------------------------------
As requ i red by Florida Statut e 553 .842 and Florida Admin istrative Code Ru le 9B-72 , please provide the infor mation and product approval number(s) for
the building components listed below as applicable to the building const r uction project fo r the permit number li sted above . You should contact you r
product supplier if you do not know the product approval number for any of the applicable listed products. Information regard i ng statewide product
approval may be obtained at: www.floridabuilding.org.
category/Subcategory Manufacturer Product Description Limitation of Use State# Local#
A. EXTERIOR DOORS
1. Swinging
2. Sli d in g
3. Sectional
4 . Garage Roll-Up
5. Automatic
6. Other
B.WINDOWS
1. Single hung
2. Horizontal slider
3. Casement
4. Double hung
5. Fixed
6.Awn ing
7. Pass -through
8. Projected
9 . Mullion
10. Wind breaker
11 . Dual action
12 . Other
Page 1 of 4 Updated 10/17/18
ROOF21-0036
Category /Subcategory Manufacturer Product Description Limitation of Use State# Local#
C. PANEL WALL
1. Sid i ng
2. Soffit s
3. EIFS
4 . Sto refronts
5 . Curtain wall s
6 . Wall louvers
7. Glass block
8. Membrane
9. Greenhouse
10. Synthetic stucco
11. Other
D. ROOFING PRODUCTS
1. Asphalt shingles 0-,ue'"' ~ Lc)(,-H /'IC A~t+-Sh,r-c: L,.:;-tu0-l-/ ;o<o 7'-/-l!.13
2. Underlayments ,1,,J -c::.,~ks _J "y(.{ • AJ!vred 1:f(j2(kJ.1. ~ ~1.-t /74o/-£l/
3. Roofing fasteners I
4. Nonstructural meta l
(nefv 1~ iwhAc ~G)f roof rn,/lr 1111,u.rl) !he/o.l 5~ (/.\-I< 8
5 . Bu ilt-up roofing -'
6 . Modified bitumen
7. Single ply roofing
8. Roofing tiles
9. Roofing insulation
10. Waterproofing
11. Wood sh i ngles/shakes
12. Roofing slate
13. Liquid applied roofing
14. Cement-adhes ive
coats
15. Roof tile adhesive
16. Spray appl ied
polyurethane roof
17. Other
Page 2 of 4 Upd ated 10/17/18
In addition to completing the above list of manufacturers, product description and State approval number for the products used on this project, the
Contractor shall maintain on the job site and available to the Inspector, a legible copy of each manufacturer's printed specifications and installation
instructions along with this Product Approval Sheet.
I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the
ones listed in this document must be approved by the Building Official.
*Contractor Name ( Print Na me): A11-f.A ,>/\/ & Ji; n. UJ U (i
*Company Name: _/-h..............,IV7.-"-'-l()U........_f _Tr~1~~---'--'-£e____._...c...u..ft..._~-=+--L--'LC=---=---------------------
*Mailing Address: __ / Li~'J_cf'_G_/~fQ~'C_;,,,_1?._1/vt_t[_<;~f _/~1-__ s_n _______________ _
*City: c4---tlao fr C &o ob. ;::-t_
*Telephone Number: ( 10 1.-/J ]/&-9 1'-(9
*State : -~h_L _____ *Zip Code: __ 5._;)_~_ro~~-------
Cell Phone Number: Fax Number: -----------------------------------------
Page 4 of 4 Updated 10/17 /18
PREMIUM ROOF REPORT
ADDRESS
64 Jackson Rd, Atlantic Beach, FL, US
Table Of Contents
Page 1
Page 2
Page 3
Page 4
Page 5
Page 6
Cover Page
Draw ing
Edge & Facet Identification
Area Diagram
Length Diagram
Pitch Diagram
Prepared on : May 26th , 2021
Prepared by : Hammer T ime Roofing
'us
tel :
Email : hammertimeroof@gmail.com
This report was generated by roofgraf.com , GRA-roofgraf.com , \ i I and subject to Sofdesk s terms of service . ' support@roofgraf.com Copyright Sofdesk Inc.
ROOF21-0036
Edge & Facet Identification
,, ~. ·· ~ ~::~zr;~~;-_:_-~ ·~, ~.
Ridge •
Hip •
Valley
Penetration
64 Jackson Rd , Atlantic Beach, FL, US
0s;· ,S' , .. ___ 71,...
7'1" 9 '8"
7 '1 0~
38' 4 "
-
53.58
21.00
6.67
0
-6'8" s· 1 · -------
11' 4" 8'
7'4"_J3' 7"
-
38' S " 38' 8 "
·-·
Rake • 49.25
Eave • 109.42
Apron Flashing • 4 .67
Step Flashing • 0.00
r ~ • ·1 ~ ,
This report is for estimation purposes only . Please make sure to verify all roof details, obstacles, slopes, dimensions prior to material ordering .
f f
This report was generated by roofgraf.com
, • r -GRA-roo gra .com , \ :-r f f and subject to Sofdesk's terms of service . support@roo gra .com
Copyright Sofdesk Inc.
ROOF21-0036
FL#: FL 5211.3-RS
Date: 10 / 11 / 2020
CBUCK E:nc;alnPEYlnQ Report No.: 20 -22 4-M-S GW -ER
Page 2 of 7
~ ~truc:tu'dl E:nQlne:aE"rlnQ CBUCK, Inc. Certificate af Authorization #8064
Manufacturer:
Product Name:
Product Category:
Product Sub-Category
Compliance Method:
Product/System
Description:
Product Assembly as
Evaluated:
Support:
Slope:
Performance:
Millennium Metals, Inc.
"M-Seam"
Roofing
Metal Roofing
State Product Approval Rule 61G20-3.005 (1) (d)
"M-Seam "
26 gauge Minimum, Steel roof panel mechanically attached to Plywood Deck with
screws .
Refer to Page 4 of this report for product assembly components/materials & standards:
1. Roof Panel
2. Fasteners
3. Underlayment
4. Insulation (Optional)
Type:
Wood Deck
(Design of support and its attachment to support framing is outside the scope of this
evaluation.)
Description:
• 15/32 (min.) or 19/32" or greater plywood,
• or Wood plank (min . specific gravity of 0.42)
Minimum slope shall be in compliance with FBC Chapter 15 Section 1507.4.2, applicable
code sections and in accordance with manufacturer's recommendations.
Wind Uplift Resistance:
• Design Uplift Pressure: Refer to Table "A"
(Refer to "Table A" attachment details herein)
FL#: FL 5211.3-RS
Date: 10 / 11 / 2020
CBUCK E:nQlnr?CYlnQ Report No.: 20-224-M-S6W -ER
Page 3 of 7
!:,pecldlh.J !:,truc:h.xdl E::nQlr,e,erlnQ CBUCK, Inc. Certificate of Authorization #8064
Performance Standards: The product described herein has demonstrated compliance with :
Standards Equivalency:
Code Compliance:
Evaluation Report Scope:
Limitations and
Conditions of Use: .
Quality Assurance:
• U L580-06 -Test for Uplift Resistance of Roof Assemblies
• UL 1897-12-Uplift test for roof covering systems
• The UL 580 -94 standard version used to test the evaluated product assembly is
equivalent to UL580-06 standard version adopted by the Florida Building Code 7th
Edition (2020).
• The UL 1897-98 standard version used to test the evaluated product assembly is
equivalent to UL1897-12 standard version adopted by the Florida Building Code 7th
Edition (2020).
The product described herein has demonstrated compliance with the performance
standards listed above as referenced in the Florida Building Code 7th Edition (2020).
This product evaluation is limited to compliance with the structural requirements of the
Florida Building Code , as related to the scope section to Florida Product Approval Rule
61620-3.001.
• Scope of "Limitations and Conditions of Use" for this evaluation :
This evaluation report for "Optional Statewide Approval" contains technical
documentation , specifications and installation method(s) which include "Limitations
and Conditions of Use" throughout the report in accordance with Rule 61620-
3.005. Per Rule 61620-3.004, the Florida Building Commission is the authority to
approve products under "Optional Statewide Approval".
• Option for application outside "Limitations and Conditions of Use"
Rule 61620-3 .005(1)(e) allows engineering analysis for "project specific approval by
the local authorities having jurisdiction in accordance with the alternate methods
and materials authorized in the Code". Any modification of the product as
evaluated in this report and approved by the Florida Building Commission is outside
the scope of this evaluation and will be the responsibility of others.
• This report is a building code product evaluation per FLPE rule (FAC) 61615-36 to
comply with Florida product approval rule (FAC) 61620-3 . This evaluation report is part
of the Florida Building Commission approval for the listed code related criteria . This
report by James Buckner, P.E. and CBUCK Engineering is not a design certification of
code compliance construction submittal documentation, per FBC section 107, for any
individual structure, site specific or permit design.
• All metal components and fasteners shall be corrosion resistant in accordance with
applicable sections of FBC, including but limited to Sections 1504.3.2, 1506.6 and
1507.4.4.
• Design of support system is outside the scope of this report.
• Fire Classification is outside the scope of Rule 61620-3, and is therefore not i ncluded in
this evaluation.
• This evaluation report does not evaluate the use of this product for use in the High
Velocity Hurricane Zone code section . (Dade & Broward Counties)
The manufacturer has demonstrated compliance of roof panel products in accordance
with the Florida Building Code and Rule 61620-3.005 (3) for manufacturing under a
quality assurance program audited by an approved quality assurance entity through
Keystone Certifications, Inc . (FBC Organization#: QUA 1824).
FL#: FL 5211.3-RS
Date : 10 / 11 / 2020
CBUCK E:nQlnf?EYlnQ Report No.: 20-224 -M-S6W -ER
Page 4 of 7
!::,pecldlh.J !::.truc:turdl E:nQlnA?rlnQ CBUCK, Inc . Certificate of Authorization #8064
Components/Materials
(by Manufacturer):
Components/Materials
(by Others):
Roof Panel:
Product Identification :
Material:
Thickness:
Panel Width:
Rib Height:
Yield Strength :
Corrosion Resistance:
Fastener:
Type :
Size :
Penetration Through :
Corrosion Resistance :
Standard:
Underlayment:
M -Seam
Steel
26 gauge Minimum
16" (max.) Coverage
1"
40 ksi min .
In compliance with FBC Section 1507.4.3 :
• ASTM A792 coated, or
• ASTM A653 G90 galvanized steel
Pancake -Head Wood Screw
#10 (x length to meet min . penetration through deck)
3/16" min. through wood deck
Per FBC Section 1506.6 and 1507.4.4
Per ANSI/ASME 818.6 .4
Material and application shall be in compliance with FBC Section 1507.1.1 and in
accordance with applicable code sections and manufacturer's recommendations .
Insulation (Optional):
Type :
Thickness :
Properties:
Density :
Or Compressive Strength :
Insulation Notes:
Rigid Insulation Board
3" (max.)
2.25 pcf (lbs/ft3) min.
20 psi min .
• Rigid Insulation shall meet m inimum density OR compressive strength.
• Insulation shall comply with FBC Section 1508 . When insulation is incorporated,
fastener length shall conform to penetrate thru bottom of support a minimum of
3/16".
FL#: Fl 5211.3-RS
Date: 10/11/2020
CBUCK E:nQlneerlnQ Report No.: 20-224 -M-SGW -ER
Page 5 of 7
~dlh.J !:,truc::t"LXdl E:nQlnE"E"rlnQ CBUCK, Inc. Certificate of Authoriz ation 118064
Installation:
Referenced Data:
Installation Method:
(Refer to drawings on Pages 6-7 of this report .)
• Fastener spacing : Refer to Table "A" Below
(along the length of the panel)
• Rib Interlock: Snap Lock
(Panel ribs shall be fully engaged to form an integral interlock.)
• Minimum fastener penetration thru bottom of support, 3/16".
• For panel construction at the end of panels, refer to manufacturer's instructions and
any site specific design.
TABLE "A"
ALLOWABLE LOADS
METHOD 1: METHOD 2:
* Design Pressure: -84.25 PSF -91.75 PSF
Deck Thickness : 15/32" or 19/32" 15/32" or 19/32"
Fastener Spacing : 8 " 4"
* Allowable design pressure for allowable stress design (ASD) with a margin of
safety of 2 to 1.
Install the "M-Seam " roof panel assembly in compliance with the installation method
listed in this report and applicable code sections of FBC 7th Edition (2020). The
installat ion method described herein is in accordance with the scope of this evaluation
report. Refer to manufacturer's installation i nstructions as a supplemental guide for
attachment.
1. UL580-94 & UL 1897-98 Uplift Test
By Hurricane Test Laboratory, LLC (FBC Organization #TST ID : 1527)
Report#: 0232 -0508-05, Report Date: 6/29/05, Specimens #1-3
2. Quality Assurance
By Keystone Certifications, Inc . (QUA ID : 1824)
Millennium Metals Licensee# 423
3. Equivalency ofTest Standard Certification
By James L. Buckner, P.E. @ CBUCK Engineering
(FBC Organization# ANE 1916)
4. Certification of Independence
By James L. Buckner, P.E .@ CBUCK Engineering
(FBC Organization# ANE 1916)
FL#: FL 5211.3-RS
Date : 10 / 11 / 2020
CBUCK E:nQlnPEYlnQ Report No .: 20 -224-M-S6W -ER
Page 6 of 7
~ ~truc::h..-dl E:nQlnE?A"lnQ CBUCK, Inc. Certificate of Authorization #8064
Installation Method
Millennium Metals
"M-Seam" Roof Panel Attached to Wood Deck
Profile Drawings
j_i------1--
~ ll
-I J_ _____ __;:,(\._ __ ~_
~ l.
16'' ~
Typical Panel Profile View (Not To Scale)
16''0.C.
·lntegal Snap Lod<
____ #10 Pcnc:ake-Head Screw
· 3116'' nin. penetratioo ttru deck
Typical Assembly Profile View (Not To Scale)
FL#: FL 5211.3-RB
Date: 10/11/2020
CBUCK E:nc;,lnPEYlnQ Report No.: 20-224-M-S6W -ER
Page 7 of 7
Installation Method
Millennium Metals
CBUCK, Inc. Certificate of Authorization #8064
"M-Seam" Roof Panel Attached to Wood Deck
Fastener:
#10 Parca<e-t-m:J :--cTF-----
.awn:
-15/'5.2' er 1~'52' CDX AyMm [a::k, er
lnsuciim:
·(Q:xicml) 'J' rrax er 25 r:s rrin.
-V\txxl perk
Typical Assembly Profile View (Not To Scale)
TABLE "A"
ALLOWABLE LOADS
METHOD 1: METHOD 2:
* Design Pressure: -84.25 PSF -91.75 PSF
Deck Thickness : 15/32" or 19/32" 15/32" or 19/32"
Fastener Spacing : 8" 4"
* Allowable design pressure for allowable stress design (ASD) with a margin of
safety of 2 to 1.
MILLENNIUM
METALS, INC .
10200 EASTPORT ROAD JACKSONVILLE, FL 32218
904-358-8366 WATTS 1-877-357-7663 (ROOF)
FAX 904-358-8285
Net Coverage 1 6" Nomina l
PANEL PROFILE
Sidelap Detail Nailstrip Detail
NOTES:
1. M-Seam Panels are only available with minor ribs to reduce oil
canning.
2. Oil canning is inherent to all metal panels and therefore is not
considered a manufacturers defect nor a warranty condition.
3. Consult your contractor immediately if you need information
concering this condition.
DIMPLE APROX .
EVERY 4 " O.C.
STARTER/ENO
SLOT APROX. 2 "
FROM PANEL
ENDS
Gauge Finishes Nominal Thickness ASTM & Grade Specifications
26 Acrylic Galvalume .0179
26 PTO Galvalume * .0179
24 Acrylic Galvalume .0240
• PTO Galvalume is 70% Kynar 500 or Hylar 5000 PVDF Resin unless otherwise indicated .
Millennium Metals Offers a Limited 25 year warranty on Painted Panels , 20 year limited warranty on Mill Finished Acrylume Panels.
Please request warranty Information from your distributor.
MILLENNIUM METALS INC.
TOLL FREE: 1-877-358-7663
FAX: 904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04
ASTM A-792 AZ55
ASTM A-792 AZ55
ASTM A-792 AZ55
PAGE 1
MILLENNIUM
METALS , INC ..
10200 EASTPORT ROAD JACKSONVILLE, FL 32218
904-358 -8366 WATTS 1 -877-357-7663 (ROOF)
FAX 904-358 -8285
M-Seam Installation Instructions:
Panel Attachment: M-Seam recommended attachment is 8" on center along the edge of the nailer strip.
This attachment may not be suitable for all applications. Projects may require an engineer to evaluate
conditions such as mean height, exposure type, and roof configuration as indicated in ASCE 7-98 and
ASCE 7-02 . Additional fasteners may be required along the end zones on the panel (eave , ridge, and
perimeter).
Pitch Alert: This product should not be used on applications less than a 2/12 pitch.
Roof Application:
Step 1: Make sure deck is even and square .
Step 2: Panel should begin on the gable end opposite of the prevailing wind. Begin with the receiving
edge of panel (female side) along the Gable (see Gable Rake Detail). The edge away from the Gable
should be the nailstrip. After checking that the panel is square to the eave, make sure the panel is
attached as indicated in panel attachment (see above) and also 2" from the leading and trailing end o f
the panel on the nailstrip . The screw should be placed in the center of the nailstrip slot provided.
Sealant is recommended on applications less than a 3/12 pitch.
Step 3 : After attaching the first panel completely, panel 2 should be snapped in place using a rubber
mallet. A minimum of l" overhang is recommended at the eave. Typical eave detail requires the use
of a hemming tool to hem the panel over the ED2 ( detail has 1-1/2" overhang).
Install the remaining accessories . Millennium Metals offers a variety of products such as pipe boots ,
butyl tape , and ventilation materials. Do not use copper or lead products in conjunction with M-Seam
as it will void the warranty.
ATTENTION INSTALLER : PLEASE REFER TO THE IMPORTANT NOTE SECTION OF THIS
MANUAL FOR SAFETY, STORAGE, OIL CANNING DISCLAIMER, AND SHAVING
DISCLAIMER PRIOR TO BEGINNING PROJECT.
Code requirements vary from area to area and job type as well as roof configuration. Job specific
engineering is not a service prov ided by Millennium Metals. Estimates/Takeoft's are provided at a
nominal fee for materials only. It is the sole responsibility of the customer to review the takeoff and
make any changes to the quantity , length or accessories h e/she feels necessary. Millennium Metals
takes no responsibility as to the accuracy of the information provided.
M-Seam is a special order product and therefore is not returnable . Please verify all items prior to
ordering.
MILLENNIUM METALS INC.
TOLL FREE: 1 -877 -358 -7663
FAX : 904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6 /04 PAGE 2
Important Notes:
MILLENNIUM
METALS, INC.
10200 EASTPORT ROAD JACKSONVILLE, FL 32218
904-358 -8366 WATTS 1 -877-357-7663 (ROOF)
FAX 904-358-8285
Millennium Metals recommends licensed roofing professionals to install our materials . Please
use gloves , glasses , and other protection when handling material to prevent injury . It is
necessary to inspect deck integrity to insure it is safe to walk on before beginning any work.
Millennium Metals recommends all installers follow the OSHA requirement for fall protection.
Never walk on materials when wet or when unsuitable weather conditions are present.
Storage:
Materials should be installed immediately. Any unused materials should be stored in a dry
place where moisture will not reach and penetrate bundles. Material should always be placed
on wood block to separate from the ground or concrete . Do not cover with plastic!!! In stead ,
use loose canvas tarps so that air can circulate. Cut the bands so that the material can expand.
Millennium Metals warrants the material only. We do not offer weather tightness warranties.
Any such warranty is up to the contractor to include in their contract.
Decking:
Millennium Metals recommends the use of minimum ½" plywood or OSB Board attached in
accordance with code. The deck must be supported by an engineered truss system not to exceed
24" on center. A moisture barrier such as 30# felt or other ASTM approved underlayment
should be used over decking to control moisture. Metal should never come in direct contact
with green or pressure treated lumber as it will cause corrosion. If tin tabs are required to attach
felt it will be necessary to apply a 15# felt in the direction of the panel as an additional
separation barrier. M-seam is recommended on application with 2-1/2 I 12 or greater.
Oil Canning Disclaimer:
Oil canning is industry wide and inherit to all metal panels. It is more visible in designs with
flat spans as with this panel. Oil canning is a wavy appearance in the surface of the metal panel.
This slight distortion in no way effects the warranty nor is a reason for rejection or refusal.
Shavings Disclaimer:
When using fasteners to penetrate steel sheets the iron particles tend to go airborne and settle
on the sheet. It is necessary to remove these particles to prevent embedment and rust marks.
MILLENNIUM METALS INC.
TOLL FREE: 1-877 -358 -7663
FAX : 904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE 3
en
C
~ m
C)
~
~
0
C) ::c
~
C) m
::E ....,
~ ::c
0
C
~
:z
0
~ ....,
C) m
HS-1
HIGH-SIDE EAVE
PAGE?
MILLENNIUM
METALS, INC .
10200 EASTPORT ROAD JACKSONVILLE, FL 32218
904 -358-8366 WATTS 1 -877 -357-7663 (ROOF)
FAX 904 -358-8285
EW-3
ENDWALL
PAGE 11
SW-3
SW-4
SIDEWALL
PAGE 10
SW-4 or SW-3
SIDEWALL
PAGE10
RC-10
RC-15
RIDGE
PAGE6
M-SEAM DETAIL LOCATIONS
RC-10
HIP
PAGE6
SR-1
GR-9
RAKE EDGE
PAGES
PANEL PROFILE
PAGE 1
ED-2
EAVE DRIP
PAGE?
TF-2
TRANSITION
PAGE9
1 EAVE DRIP (EF-5)
~/PAINT
ll'St··
1/2-Q
4. GABLE RAKE (GR-9)
3-1/8"
~
-
5/a"S
,.!, X)/2"
5/8")y
7. HIP CAP (RC-10)
~
~-3/8"
11 TRANSITION FLASHING (TF 2)
15. RIDGE CAP (BC-20)
* 1 3/8"
FLASHING PROFILES
MILLENNIUM METALS INC.
TOLL FREE: 1-877-358-7663
FAX: 904-358-8285
MILLENNIUM
METALS, INC.
10200 EASTPORT ROAD JACKSONVILLE, FL 32218
904-358-8366 WATTS 1-877-357-7663 (ROOF)
FAX 904-358-8285
2. ENDWALL FtASHING (EW-3}
/PAINT ~ItSs
1/2-1;;1-
4 GABLE RAKE (GR-9Rl
3-1/4"
I I ~0
5/8': .,~4
5/8'~
8. J-CHANNEL (JC-7)
4-1 /2"
1 2. SIDEWALL FLASHING (SW-3)
3 EXTENDED EAVE (ED-2)
~PAINT ,~r 1,;2·
( 1/2"11~5/8"
OVERHANG: 1-t
5. GAMBREL FLASHING (GF -2)
9 . PREFORMED VALLEY (PV-3)
13. STEP RAKE (SR-1 )
3"
1" nu-N
-I+ :::-
1 / 2" ,), ~ 5/8"
1/2>s<.
3 EXTENDED EAVE CED-2Rl
~PSNT
~11/2"
5/8;,x
OVERHANG: 1 -t
6 HIGHSIDE EAVE (HS-J)
10 STEP SIDEWALL (SW-4)
14 COUNTER FLASHING (CF -1)
OFFSET CLEAT CCL-2) Z-CLOSURE (ZC-1 l REGLET FLASHING /RF -1 l
1/2"
SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04
1"
++ 7_-,-+ 4-'=+ 1]~
PAGE 5
RIDGE CAP
MILLENNIUM
METALS, INC.
10200 EASTPORT ROAD JACKSONVILLE, FL 32218
904-358 -8366 WATTS 1 -877 -357-7663 (ROOF)
FAX 904-358 -8285
STITCH SCREWS
0 12" O.C., DO NOT OVERDRIVE
M-SEAM PANEL
VENTING
MATERIAL
7JILllll_lllLllff&
30/1 FELT
ATTACHED PER CODE
APPROVED SOLID SUBSTRATE
VENTED RIDGE DETAIL RC-15
RIDGE CAP RC-1 0/RC-20
S.S. POP RIVETS
•z• CLOSURE CUT TO FIT BETWEEN
PANEL, (3) /110-12 X 1" PANCAKE
HEAD SCREWS PER PANEL
CONT . BUTYL TAPE SEALANT
APPROVED SOLID SUBSTRATE
/130 FELT
ATTACHED PER CODE
HIP /RIDGE FLASHING
MILLENNIUM METALS INC.
TOLL FREE: 1 -877-358-7663
FAX : 904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE 6
#10-12 X 1" PANCAKE
HEAD SCREWS O 12" O.C.
M-SEAM PANEL
/130 FELT
ATTACHED PER CODE
APPROVED SOLID SUBSTRATE
CLEAT W/ /110-12 X 1•
MILLENNIUM
METALS, INC.
10200 EASTPORT ROAD JACKSONVILLE, FL 32218
904 -358 -8366 WATTS 1 -877 -357 -7663 (ROOF)
FAX 904 -358 -8285
M-SEAM HEMMED
PANCAKE HEAD SCREW C 12" O.C. /
FASCIA BOARD_/
SEE DETAIL FOR HEMMING
PANEL PAGE 3
EAVE DRIP DETAIL ED-2 EAVE FLASHING PANEL SHOWN SHORT TO DEPICT
M-SEAM PANEL
l!J_;z___~
APPROVED SOLID 7
SUBSTRATE
#30 FELT
ATTACHED PER CODE
CLEAT W/
/110-12 X 1" PANCAKE
HEAD SCREWS O 12" O.C.
~---CONT.BUTYL
TAPE SEALANT
HIGHSIDE EAVE DETAIL HS-1
MILLENNIUM METALS INC.
TOLL FREE: 1 -877 -358 -7663
FAX :904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6 /04
DETAIL. MAKE IT FLUSH AND MAKE HOLE.
PAGE 7
START
MILLENNIUM
METALS, INC.
10200 EASTPORT ROAD JACKSONV I LLE , FL 32218
904 -358 -8366 WATTS 1 -87 7-35 7-7663 (ROOF )
FAX 904 -358 -8285
30# FELT ATTACHED PER CODE
12· o.c.
CONT. BUTYL TAPE SEALANT
STEP GABLE FLASHING
APPROVED SOLID SUBSTRATE
~--FASCIA
STEP GABLE RAKE DETAIL SR-1
CLEAT W/#10-12 X 1•
PANCAKE HEAD SCREWS
30# FELT
ATTACHED PER CODE
APPROVED SOLID SUBSTRATE
M-SEAM PANEL
END
FlaD BEND
PANEL 1 • MIN .
CONT. BUTYL
TAPE SEAIANT
STITCH SCREWS
0 12· o.c.
END
FJELD BEND
PANEL 1 • MIN .
CONT . sum
TAPE SEALANT
"Z" CLOSURE
STITCH SCREWS
0 12· o.c .
"Z" CLOSURE CUT TO FlT BETWEEN PANEL.
(3) #12 X 1 WHS PER PANEL
START
GABLE RAKE DETAIL GR-9
CONT. sum TAPE SEALANT
FASCIA
CLEAT W/ #10-12 X 1•
PANCAKE HEAD SCREWS
MILLENNIUM METALS INC.
TOLL FREE: 1 -877 -358-7663
FAX : 904-358-8285 SUBJECT TO CHANGE WITHOU T NOTICE 10/6 /04 PAGE 8
MILLENNIUM
METALS, INC.
10200 EASTPORT ROAO JACKSONVILLE, FL 32218
904-358-8366 WATTS 1-877-357-7663 (ROOF)
FAX 904-358-8285
VALLEY FLASHING
CLEAT SET IN BUTYL TAPE
SEALANT W/ #10-12 X 1"
PANCAKE HEAD SCREWS 6" O.C.
APPROVED SOLID SUBSTRATE
CONT. BUTYL
TAPE SEALANT
PREFORMED VALLEY DETAIL PV-3
OFFSET CLEAT SET IN
BUTYL TAPE SEALANT
W/ #10-12 X 1" PANCAKE
HEAD SCREWS O 12" O.C.
CONT . BUTYL TAPE SEALANT
7." CLOSURE CUT TO FIT BETWEEN
PANEL. (3) #10-12 X 1" PANCAKE
SCREWS PER PANEL
TRANSITION DETAIL
MILLENNIUM METALS INC.
TOLL FREE: 1-877-358-7663
FAX:904-358-8285
•
~--TRANSITION
FLASHING
___ S.S . POP RIVETS
0 12· o.c.
SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04
-SEAM PANEL
f FELT
ATTACHED PER CODE
APPROVED SOLID SUBSTRATE
PANEL
PAGE 9
SEALANT
CONT.
STEP SIDEWALL
FLASHING
#30 FELT
ATTACHED
PER CODE
APPROVED SOLID
SUBSTRATE
STITCH SCREWS
0 12" o.c.
CONT. BUTYL TAPE
SEALANT
M-SEAM PANEL
MILLENNIUM
METALS, INC.
10200 EASTPORT ROAD JACKSONVILLE, FL 32218
904-358 -8366 WATTS 1 -877-357-7663 (ROOF)
FAX 904-358-8285
SEALANT
CONT . BUTYL
TAPE SEALANT
SURFACE-MOUNT
COUNTER FLASHING
SIDEWALL FLASHING
S.S. POP RIVET
@ 12" o.c.
"z" CLOSURE CUT TO FIT
BETWEEN PANEL, (3) #12 X 1
PANCAKE SCREWS PER PANEL
CONT . BUTYL TAPE
SEALANT
#30 FELT .::.,_, ,.,_
ATTACHED PER CODE ~.;_:
APPROVED SOLID
SUBSTRATE
M-SEAM PANEL
SIDEWALL FLASHING DETAIL SW-3 & SW-4
SEALANT
REGLET
FLASHING
SAW CUT
MASONARY WALL
STEP
SEALANT-----
CONT. BUTYL--+---.tP,QI
TAPE SEALANT
CONT . BUTYL
TAPE SEALANT
SIDEWALL FLASHING
SIDEWALL COUNTER FLASHING OPTIONS
MILLENNIUM METALS INC.
TOLL FREE: 1 -877 -358 -7663
FAX :904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6/04 PAGE 10
SEALANT
CONT . BUTYL
TAPE SEALANT
SURFACE MOUNT
COUNTER FLASHING
HEADWALL FLASHING
CONT . BUTYL TAPE SEALANT
"Z" CLOSURE CUT TO FIT BETWEEN
PANEL, (3) # 10-12 X 1" PANCAKE
HEAD SCREWS PER PANEL
S.S . POP RIVETS
M-SEAM PANEL
MILLENNIUM
METALS, INC .
10200 EASTPORT ROAD JACKSONVILLE, FL 32218
904-358 -8366 WATTS 1 -877 -357 -7663 (ROOF)
FAX 904-358 -8285
APPROVED SOLID SUBSTRATE ======~~~
#30 FELT ATTACHED PER CODE
ENDWALL DETAIL EW-3
SEALANT
REGLET
FLASHING
SAW CUT
MASONARY WALL
STEP
SEALANT
CONT . BUTYL
TAPE SEALANT
CONT . BUTYL
TAPE SEALANT
SIDEWALL FLASHING
ENDWALL COUNTER FLASHING OPTIONS
MILLENNIUM METALS INC.
TOLL FREE: 1-877 -358 -7663
FAX : 904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10/6 /04 PAGE 11
CAULK
MILLENNIUM
METALS, INC.
10200 EASTPORT ROAD JACKSONVILLE, FL 32218
904 -358 -8366 WATTS 1 -877-357 -7663 (ROOF)
FAX 904-358-8285
PANEL HEMMING
CUT PANEL BACK 1 r TO
CREATE HEM . USE HEMMING TOOL.
MILLENNIUM METALS INC.
TOLL FREE: 1-877-358-7663
FAX : 904-358-8285 SUBJECT TO CHANGE WITHOUT NOTICE 10 /6/04 PAGE 12
Proposal
HAMMER
ROOFING , LLC. IME
14286 Beach Blvd Ste 19-386
CCC1329983
Phone: 904.716.9149
Email: Hammertimeroof®amail.com
Name Phone Date
Brendan Sexton 5-5-2021
Street City, State
64 Jackson Rd Atlantic Beach, Fl 32233
Email Fax
falonsexton@gmail.com
Roof Type: Compostion Shingles
We hereby submit specifications and estimate for:
Remove and replace shingles with :
Color: Customer Choice
Manufacturer: Owens Coming (Duration)
Type: Limited Lifetime architectural
Eave Drip Color: Customer Choice
*[nspect and replace any rotted decking(if any)
Nail decking off to proper wind mitigation code using 8d ring shank nails.
Install new 6" galvanized eave metal to perimeter of roof.
( x) Peel and stick Ice and Water Shield.
( x ) Lead Plumbing Boots l " _l _2" _I _3 "
( x) Off Ridge Vents 4' ----''--6'
( ) Install Cobra ventilation upgrade
( ) Dryer Vent
( ) Kitchen Vent
Install new ridge cap shingles to all hips and ridges.
Clean up and removal of all debris.
Magnetize perimeter of job site .
Includes permit and dumpster
Shingles to entire roof including front-$7,700
Shingles to main and Metal Roof Front-$9,200
Miscellaneous
Comments:
Rafter tails-This will be priced per tail. Cut back bad
ones back to wall. Scab new tail to existing.
$200 per tail. Material and Labor( Additional)
Metal Roof to Front Area-
Galvalume painted standing seam metal roof.
I inch seam .
* Any rotted wood discovered (if any) will incur an additional charge as follow:
Plywood per 4x8 sheet:$ 110.00 ¾ plywood
Linear Wood : $9.00 per foot
Ice and water shield to entire roof sheathing additional -~ln=c~lu=d~ed~---~
We hereby propose to furnish labor and material-complete in accordance with the above specifications, for the sum of.
--~N=in=e~T=ho~u=s=a=n=d~Tw~o~H=u=n=d~red~D~o=lla=r=s ____ ($ 9,200 )
-~$~4=0~0~0 _______ Deposit -~$=5-=,2,..,0-=-0 _____ Balance on Completion
All material is guaranteed to be as specified. A ll work is to be completed in a workmanlike manner according to
standard practices. Any alteration or deviation from the above specifications involving extra costs will be executed
upon written and or verbal order from appropriate managing authority and will become an extra charge over and
above the estimate. We can take rain gutters down that are attached to eave metal(one story onl y/ additional charge
for 2 and 3 story houses) and place th em to the s id e but we w ill not be responsibl e for re-installation. We will not
take down any super gutters that are located on back scree ned in porches. Gutter/Screen Enclosure company will
need to be contacted. Not responsible for damage to driveway that may occur during material delivery/roll off
container placement. We wi ll not be liab le for flat tires to lawn mowers, car tires and injury from nails that could
occur due to roofing construction demolition an d replacement. We cannot guarantee every nail that is removed will
be picked up with the magnet but we will do a thorough clean up upon completion . We w ill not be held
responsible for replacement of any pictures/decorations that could possib ly fal l or come loose during delivery of
material or during roofing installation. Not responsible for roof leaks in areas other than those worked on. Under
no circum stances is Hammer Time Roofing LLC responsible for existing damages to building, its contents or roof
deck. All agreements contingent upon strikes, accident or de lays beyond our control. Owner to carry Fire, Tornado
and other necessary insurance. This pro posal subject to acceptance within 30 days and it is void thereafter at the
option of the unders igned. Invoices not paid in full within 30 days will incur a 2.0% per month charge until paid in
full.
Authorized Signa tu re: Anthon y Betancour t 5-19-2021
ACCEPTANCE O F PROPSAL
The above prices, specifications and conditions are hereby accepted . You are authorized to do the work as
s pecified. Payment will be made as outlined above.
Signature: _______ _
Signature: ______ _
Date of acceptance: ______ _
GUARANTEE:_5_ year(s) roof leak free repair under normal weather conditions from completion date.
The warranty shall protect the owner from damage to the building and contents resulting from the leakage
for a period of (5) year(s) beginning from the date of completion of the project. The warranty shall cove r
and include repair or replacement of any damaged exterior structure, interior structure, interior components
and contents of the building, resulting from roof leakage directly attributed to the contractor 's
workmanship.
~CCORDING TO FLORIDA 'S CONSTRUCTION LIEN LAW (SECTIONS 713.001 -713.37. FLORIDA STATUTES), THOSE
WHO WORK ON YOUR PROPERTY OR PROVIDE MATERIALS AND SERVICES AND ARE NOT PAID IN FULL HAVE A
RIGHT TO ENFORCE THEIR CLAIM FOR PAYMENT AGAINST YOUR PROPERTY . THIS CLAIM IS KNOWN AS A
CONSTRUCTION LIEN . IF YOUR CONTRACTOR OR A SUBCONTRACTOR FAILS TO PAY SUBCONTRACTORS, SUB-
SUBCONTRACTORS, OR MATERIAL SUPPLIERS, THOSE PEOPLE WHO ARE OWED MONEY MAY LOOK TO YOUR
PROPERTY FOR PAYMENT, EVEN IF YOU HAVE ALREADY PAID YOUR CONTRACTOR IN FULL. IF YOU FAIL TO PAY
YOUR CONTRACTOR. YOUR CONTRACTOR MAY ALSO HAVE A LIEN ON YOUR PROPERTY . THIS MEANS IF A LIEN IS
FILED YOUR PROPERTY COULD BE SOLD AGAINST YOUR WILL TO PAY FOR LABOR, MATERIALS, OR OTHER SERVICES
THAT YOUR CONTRACTOR OR A SUBCONTRACTOR MAY HAVE FAILED TO PAY . TO PROTECT YOURSELF, YOU SHOULD
STIPULATE IN THIS CONTRACT THAT BEFORE ANY PAYMENT IS MADE, YOUR CONTRACTOR IS REQUIRED TO
PROVIDE YOU WITH A WRITTEN RELEASE OF LIEN FROM ANY PERSON OR COMPANY THAT HAS PROVIDED TO YOU A
"NOTICE TO OWNER." FLORIDA'S CONSTRUCTION LIEN LAW IS COMPLEX, AND IT IS RECOMMENDED THAT YOU
CONSULT AN ATTORNEY .