Loading...
1085 Atlantic Blvd Fire Hydrant Inspection rr � FTiTUD ° FIRE PROTECTION -® 2430 University Blvd., West * Jacksonville, FL 32217 * 904-733-9008 www.fortitudefire.com FIRE HYDRANT INSPECTION Owner: Owner Phone Number: Owner Address: Property Being Evaluated: Seaside Apts Property Address: 1085 Atlantic Blvd Atlantic Beach 32233 Date of Work: 6/8/2021 All responses refer to the current work (inspection, testing and maintenance) performed on this date. This work is (check one): •Annual ❑ 5 Year Flow Test ❑ Existing ❑ Repaired ❑ New Device Part I — Owner or Owner Owner or Owner Representative Printed Name Date M Rep. Not Onsite Part II — Inspector's Section 1. Location of Hydrant: Bldg 2 2. Make / Model of Hydrant: Kennedy K 11 3. Size of Hydrant: 4 1/2 4. Color of Hydrant: Yellow 5. Is Hydrant housing accessible? ® Yes ❑ No ❑ N/A 6. Housing free of external damage? Yes ❑ No = N/A 7. Is the operating wrench available? Yes ❑ No [ N/A 8. Does associated piping appear to be free of leaks? • Yes ❑No ❑ N/A 9. Do all the control valve(s) appear to be open? It Yes ❑ No ❑ N/A 10. Is isolation valve accessible? pp Yes ❑ No ❑ N/A 11. Free of leaks (external)? ® Yes ❑ No E N/A 12. Operating nut is in good condition? ® Yes _ No _ N/A 13. Threads of nozzles / caps in good condition? • Yes No ❑ N/A 14. Gaskets on caps in good condition? 1. Yes fl No ❑ N/A 15. Is Hydrant in normal open / closed position? ® Yes ❑ No ❑ N/A 16. Does operating nut appear to work thru full range? IlYes n No ❑ N/A 17. Water flowed for 60 seconds or until clear? • Yes ❑ No ❑ N/A 18. Free from foreign material in barrel? pp Yes ❑ No ❑ N/A 19. Does Hydrant drain in 60 minutes or less? Yes ❑ No ❑ N/A 20. Hydrants requiring pumping identified? ❑ Yes ❑ No ® N/A 21. Threads / caps / stems / plugs lubricated? ®Yes ❑ No ❑ N/A 22. Has a 5-year flow test been performed per NFPA 25? II Yes ONo ❑ N/A Part II — Comments(any"NO"answers,test failures or other problems found with the hydrant inspection must be explained here. Also,note here any products noticed on the system that have been the subject to a recall or replacement program) ** See Diagram ** Part III — Recommendations (Not a part of the NFPA-25 inspection,the following items may need to be reviewed by a fire protection engineer) MO 5 Year Flow Test Results(if applicable): Static: All11111.° Residual_ Pitot: GPM @ 20 psi: — r:( ía 4........... Part IV — Inspectors Information I state that the information on this form is correct at the time and place of my inspection and that all equipment tested at this time was left in operation conditional upon completion of this inspection except as noted in part Ill above. Date: 6/8/2021 Printed Name of Inspector: Jason Kestner / Signature of Inspector: 7`1' License or Certificate Number (if applicable): FPI21-000025 Color of Tag Placed on System: n Red ni Green Yellow rwrwP FORTITUDE FIRE PROTECTION 2430 University Blvd., West * Jacksonville, FL 32217 * 904-733-9008 vvww.fortitudefire.corn FIRE HYDRANT INSPECTION Owner: Owner Phone Number: Owner Address: Property Being Evaluated: Seaside Apts Property Address: 1085 Atlantic Blvd Atlantic Beach 32233 Date of Work: 6/8/2021 All responses refer to the current work (inspection, testing and maintenance) performed on this date. This work is (check one): 'Annual ❑ 5 Year Flow Test ❑ Existing 0 Repaired 0 New Device Part I — Owner or Owner Owner or Owner Representative Printed Name Date Rep. Not Onsite Part II — Inspector's Section 1. Location of Hydrant: Bldg 4 2. Make / Model of Hydrant: American Darling B84B-5 3. Size of Hydrant: 5 1/4" 4. Color of Hydrant: Yellow 5. Is Hydrant housing accessible? ® Yes ❑ No ❑ N/A 6. Housing free of external damage? • Yes No ❑ N/A 7. Is the operating wrench available? Yes ❑ No I N/A 8. Does associated piping appear to be free of leaks? N Yes ❑No ❑ N/A 9. Do all the control valve(s) appear to be open? ® Yes ❑ No ❑ N/A 10. Is isolation valve accessible? • Yes ❑ No ❑ N/A 11. Free of leaks (external)? • Yes ❑ No ❑ N/A 12. Operating nut is in good condition? ® Yes ❑ No ❑ N/A 13. Threads of nozzles / caps in good condition? ® Yes ❑ No [ N/A 14. Gaskets on caps in good condition? • Yes ❑ No ❑ N/A 15. Is Hydrant in normal open / closed position? ® Yes ❑ No ❑ N/A 16. Does operating nut appear to work thru full range? II Yes n No ❑ N/A 17. Water flowed for 60 seconds or until clear? Yes ❑ No ❑ N/A 18. Free from foreign material in barrel? "' Yes ❑ No ❑ N/A 19. Does Hydrant drain in 60 minutes or less? 1. Yes ❑ No 0 N/A 20. Hydrants requiring pumping identified? 0 Yes 0 No ® N/A 21. Threads / caps / stems / plugs lubricated? MI Yes fl No 0 N/A 22. Has a 5-year flow test been performed per NFPA 25? ®Yes ENo 0 N/A Part II —Comments(any"NO"answers,test failures or other problems found with the hydrant inspection must be explained here. Also,note here any products noticed on the system that have been the subject to a recall or replacement program) ** See Diagram ** Part III — Recommendations (Not a part of the NFPA-25 inspection,the following items may need to be reviewed by a fire protection engineer) a:a 5 Year Flow Test Results(if applicable): Static: Residual: --_ Pitot: GPM @ 20 psi: 111. 0 D. ii 4.........., Part IV— Inspectors Information I state that the information on this form is correct at the time and place of my inspection and that all equipment tested at this time was left in operation conditional upon completion of this inspection except as noted in part Ill above. Date: 6/8/2021 Printed Name of Inspector: Jason Kestner Signature of Inspector: ( A y License or Certificate Number (if applicable): FPI21-000025 Color of Tag Placed on System: I I Red *Green ri Yellow