338 7th St RES21-0129 Interior RemodelOWNER:ADDRESS:CITY:STATE:ZIP:
DAVID & SHANNON
BOSSBALY 338 7th ST ATLANTIC BEACH FL 32233
COMPANY:ADDRESS:CITY:STATE:ZIP:
PETER COALSON DESIGN
FOR FLORIDA LLC 1614 COQUINA PLACE ATLANTIC BEACH FL 32233
TYPE OF
CONSTRUCTION:
REAL ESTATE
NUMBER:ZONING:BUILDING USE
GROUP:SUBDIVISION:
169894 0010 ATLANTIC BEACH
JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK:
338 7TH ST RESIDENTIAL ALTERATION
RESIDENTIAL INTERIOR REMODEL $69000.00
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
BUILDING PERMIT 455-0000-322-1000 0 $356.00
BUILDING PLAN CHECK 455-0000-322-1001 0 $178.00
STATE DBPR SURCHARGE 455-0000-208-0700 0 $8.01
STATE DCA SURCHARGE 455-0000-208-0600 0 $5.34
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN
YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT
MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU
INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT.
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
1 of 2Issued Date: 4/27/2021
PERMIT NUMBER
RES21-0129
ISSUED: 4/27/2021
EXPIRES: 10/24/2021
RESIDENTIAL PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
TOTAL: $547.35
2 of 2Issued Date: 4/27/2021
PERMIT NUMBER
RES21-0129
ISSUED: 4/27/2021
EXPIRES: 10/24/2021
RESIDENTIAL PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
RES21-0129
R
E
S
2
1
-
0
1
2
9
BOSSBALY RENOVATIONPETER COALSON DESIGN FOR FLORIDA LLC 904-759-2556
SITE PLAN
N
1" =20-0"
NO CHANGES TO SITE PLAN
LOT COVERAGE
ELECTRICAL CODE
WIND SPEED 130 MPH IMPORTANCE FACTOR 1
TYPE OF CONST.
OCCUPANCY CLASS
Type V-B
R-3
EXPOSURE C ENCLOSEDWIND
EXPOSURE
RISK LEVEL II
BUILDING CODE
REMODEL CATAGORY ALTERATION LEVEL 3
NATIONAL ELECTRICAL CODE 2014
GOVERNING CODES
7th Edition 2020
FLORIDA BUILDING CODE
GENERAL NOTES:
1. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND
DIMENSIONS AT THE JOB SITE PRIOR TO COMMENCING
WORK. THE CONTRACTOR SHALL REPORT ALL
DISCREPANCIES BETWEEN THE DRAWINGS AND EXISTING
CONDITIONS TO THE DESIGNER & OWNER PRIOR TO
COMMENCING WORK.
2. THE CONTRACTOR SHALL SUPPLY, LOCATE AND BUILD
INTO THE WORK ALL INSERTS, ANCHORS, ANGLES,
PLATES, OPENINGS, SLEEVES, HANGERS, SLAB
DEPRESSIONS AND PITCHES AS MAY BE REQUIRED TO
ATTACH AND ACCOMMODATE OTHER WORK.
3. ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS
ARE INTENDED TO BE TYPICAL AND SHALL BE
CONSTRUED TO APPLY TO ANY SIMILAR SITUATION
ELSEWHERE IN THE WORK EXCEPT WHERE A DIFFERENT
DETAIL IS SHOWN.
4. SUBSURFACE SOIL CONDITION INFORMATION IS NOT
AVAILABLE. FOUNDATIONS ARE DESIGNED FOR A SOIL
BEARING CAPACITY OF 3,000 PSF. THE CONTRACTOR
SHALL REPORT ANY DIFFERING CONDITIONS TO THE
DESIGNER & OWNER PRIOR TO COMMENCING WORK.
5. STRUCTURAL DRAWINGS SHALL BE USED IN
CONJUNCTION WITH JOB SPECIFICATION AND
ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING,
AND SITE DRAWINGS, CONSULT THESE DRAWINGS FOR
SLEEVES, DEPRESSIONS AND OTHER DETAILS NOT SHOWN
ON STRUCTURAL DRAWINGS.
6. ALL BOLTS, NUTS, WASHERS, STRAPS AND FASTENERS
INCLUDING NAILS, SHALL BE HOT DIP GALVANIZED OR
STAINLESS STEEL. CONTINUOUS ANCHORAGE SHALL BE
PROVIDED BETWEEN ALL TRUSSES, WALL SECTIONS,
BEAMS, POSTS AND FOOTINGS WITH USE OF STRAPS AND
CONNECTORS AS SPECIFIED HEREIN.
7. ALL SPECIFIED FASTENERS MAY ONLY BE SUBSTITUTED
WITH DEVICE OF EQUAL OR GREATER CAPACITY.
8. THE INSTALLATION OF THE FASTENERS SHALL BE IN
ACCORDANCE WITH THE MANUFACTURER'S
SPECIFICATIONS. WIND BRACING (1ST AND 2ND FLOORS) 4'-
0" X 8'-0" x 1/2" EXTERIOR GRADE PLYWOOD SIDING. NAIL
6" 0.C. FIELD
AND EDGE.
19. THE STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING
AND STABLE AFTER THE BUILDING IS COMPLETE. IT IS THE
CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE
ERECTION PROCEDURES AND SEQUENCE TO ENSURE
SAFETY OF THE BUILDING AND ITS COMPONENTS DURING
ERECTION. THIS INCLUDES THE ADDITION OF NECESSARY
SHORING, SHEETING, TEMPORARY BRACING, GUIDES, OR
TIE DOWNS.
INDEX OF DRAWINGS
LOT 17 BLK 8
ONE STORY FRAME
# 338 SEVENTH STREET
7TH STREET
40 ' RIGHT OF WAY
SHEET 1
SHEET 2
SHEET 3
SHEET 4
SHEET 5
SITE PLAN
EXISTING PLAN / DEMOLITION PLAN
FLOOR PLAN
MECHANICAL / ELECTRIC PLAN
CABINET PLAN
4/16/2021
SHEET 1
NO CHANGE TO IMPERVIOUS COVERAGE
FLORIDA BUILDING CODE 2020
RES21-0129
PETER COALSON DESIGN FOR FLORIDA LLC
N
DEMOLITION PLANEXISTING FLOOR PLAN
REMOVE WALL
REMOVE DOOR / WINDOW
REMOVE CABINET/ APPLIANCE
KITCHEN
DINING
FAMILY ROOM
BEDROOM 1
BEDROOM 2
MASTER
HALL BATH
REF
DUAL
RANGE
KNOOK
DEMOLITION NOTES:
DISCONNECT GAS SUPPLY
DISABLE ALL BREAKERS SAVE ONE MARKED FOR TEMP POWER
REMOVE ALL CEILING FIXATURES & FANS
REMOVE ALL A/C & RA GRILLS
ALL WALLS MARKED FOR REMOVAL ARE NON BEARING
PROTECT OPENINGS WHERE WINDOWS AND DOORS ARE REMOVED
REMOVE ALL DEBRIS DAILEY BROOM SWEEP
SAVE WINDOWS AND DOORS REMOVED
GARAGE
KITCHEN
DINING
FAMILY ROOM
MASTER
HALL BATH
REF
DUAL
RANGE
GARAGE
KNOOK
BEDROOM 1
BEDROOM 2
20
6
0
S
L
I
D
I
N
G
20
6
0
S
L
I
D
I
N
G
20
6
0
S
L
I
D
I
N
G
60
6
8
S
G
D
60
6
8
S
G
D
3-O
3-O
3-O
6068 SGD
3-
O
20
6
0
S
L
I
D
I
N
G
2060 SLIDING
50
6
8
S
G
D
3044 3044
SCALE 1/8" =1'-0"SCALE 1/8" =1'-0"
BOSSBALY RENOVATION SH2
REMOVE TILE
FLOORING / DINING
AND KITCHEN
REMOVE TILE
HEARTH & SURROUND
REMOVE ALLTILE FLOORING AND SETTING MATERIAL
4/16/2021
REMOVE
FOYER TILE
NO STRUCTRUAL CHANGES
WH D W
PETER COALSON DESIGN FOR FLORIDA LLC
FLOOR PLAN WITHSCALE 1/8" = 1'-0"
N
FASTNERS EXPOSED EXTERIOR - STAINLESS
BOSSBALY RENOVATION SH3
GARAGE
KITCHEN
FAMILY ROOM
BEDROOM 1
BEDROOM 2
MASTER
BEDROOM
BATH
NEW SHELVES (3) EACH SIDE
OF FIREPLACE
VAULTED CEILING
EN
T
R
Y
D W
HW
REMOVE
EXISTING MANTEL
& TILE SURROUND
REPLACE MANTEL ONLY REMOVE
MED. CAB
AND BATH
FIXTURES
REMOVE
WINDOW AND
INSTALL 2 NEW
EGRESS WINDOWS
REMOVE DOOR
CLOSE OPENING
OPTIONAL CEILING BEAM
APPLY STUCCO
TO EXTERIOR
STUCCO EXTERIOR
C
L
O
S
E
T
OHD DOOR TRACKS
NEW2X4
WALL
NEW ATIC ACCESS
NEW DOOR / SIX PANEL STEEL
NEW A/C GRILLS
TYPICAL
1 REMOVE TEXTURING FROM ALL CEILINGS
2 SKIM CEILINGS
3 REMOVE & REPLACE ALL BASE & CASING
4 EXISTING DOORS REMAIN
GENERAL NOTES:
REMOVE SOFFIT INSTALL
BOX FOR BRACKET LIGHT
ON WALL
6-0 6-8 SLIDER
FROM MASTER BEDROOM
NEW CABINETS / ISLAND
AND APPLIANCES BY OTHERS
PA
N
T
R
Y
NEW SHELVES
NEW 2X4 WALL
USE EXISTING CONNECTIONSRELOCATED
WATER HEATER
51/2"
NEW WIRE SHELVING
RELOCATED
5"
2-8
2-8
DINING ROOM
RELOCATE EXISTING A/C SUPPLY TO LAUNDRY ROOM
PROVIDE & REPLCE TOILET
RELOCATE GAS CONNECTION
EXTEND NEW EXHAUST VENT
AND PROVIDE NEW WALL FLANGE
FRAME FOR EXHAUST VENT
FRAMING SPECIFICATIONS
CONCRETE SPECIFICATIONS
3000 PSI CONCRETE MIN.WITH
REINFORCED FIBERMESH
STUDE #2 SPF
PLATES #2 SPF
FASTNERS INTERIOR - GALVANIZED
TROWEL FINISH, SMOOTH
(3)
4/16/2021
(2
)
3
0
5
0
W
I
T
H
M
U
L
L
ALUMNIUM MULL
REMOVE SOFFIT. INSTALL
BOX FOR BRACKET LIGHTS
ON WALL (2)
NEW ELECTRICAL OUTLETS
O O O
O
O
LOCATE
AS REQUIRED
FOR APPLIANCE
NON STRUCTURAL CONCRETE FILL
LINE OF EXISTING SLAB
O
O
O
NO STRUCTRUAL CHANGES
HEATED SQUAR FOOTAGE 1,819SQ.FT.
GARAGE SQUAR FOOTAGE 456 SQ.FT.
51/2"
TREAT FOR TERMITS WHERE SOIL EXPOSED
NEW FRENCH DOORS
30
30
36
"
36
"
SELF
CLOSSING
2-8
3'-10"6'-2"
1'
-
4
"
\
PETER COALSON DESIGN FOR FLORIDA LLC
ELECTRICAL LIGHTING / MECHANICAL PLAN
N
BOSSBALY RENOVATION SH4
NEW 10"
VENT PIPE
CLOSE GAS SUPPLY
FAN
RELOCATE GAS
CONNECTION
R
R
R
R
R
R
R
R R
R
FAN
RELOCATED SUPPLY
WH
PRESSURE
REPLACE GRILL TYPICAL
REPLACE A/C GRILL TYPICAL
R
R
R R
UNDER CABINETUNDER CABINET
REF
DW
SCALE 1/8" = 1'-0"
4/16/2021
S
S
S
S
S
NOTE:
ALL SMOKE DETECTORS
COMBINATION CARBON
DIXOIDE DETECTORS
SS
NEW TRIM
ALL EXISTING
RECESSED LIGHTS
S
S S SS
S
Co2
4"4"
E
EE
E
E
E
E
E E
EXISTING EXTERIOR FIXTURES EE
S S
S S
S
S S S
S
S
S
PETER COALSON DESIGN FOR FLORIDA LLC
KITCHEN PLAN
N
BOSSBALY RENOVATION SH5
SCALE 1/2" = 1'-0"
2X8
KNEE WALL
RELOCATED WASTE
INSTALL STUTTER VENT
RELOCATED GAS SUPPLY
SUPPLY FOR REF.
SEE SPECIFICATION
CAP EXISTING WASTE
4/16/2021
BELOW COUNTER TOP
CUT TRENCH
EXISTING LINE
UNDER CABINET LIGHTING
UNDER CABINET LIGHT
PRESSURE SWITCH
DISPOSAL
12 " UPPER
BELOW COUNTER
12 " UPPER
BELOW COUNTER
12 " UPPER
BELOW COUNTER
DUEL FUEL RANGE
C L
REF
FRAME AND DRYWALL
BOX FOR EXHAUST VENT
SEE MANUF. SPECIFICATION
7th Street
40' R W
#338
Single Story
Residence
15
0
'
15
0
'
Construction
Toilet
in Residence
MA
T
E
R
I
A
L
S
T
O
R
A
G
E
PARKING
DU
M
P
50'
50'
PETER COALSON DESIGN FOR FLORIDA LLC BOSSBALY INTERIOR RENOVATION
4/16/2021
SOLID FENCING
SOLID FENCING
SILT FENCE AS REQUIRED
SITE MANAGEMENT PLAN
SCALE 1" =1'-0"
RES21-0129