Loading...
338 7th St RES21-0129 Interior RemodelOWNER:ADDRESS:CITY:STATE:ZIP: DAVID & SHANNON BOSSBALY 338 7th ST ATLANTIC BEACH FL 32233 COMPANY:ADDRESS:CITY:STATE:ZIP: PETER COALSON DESIGN FOR FLORIDA LLC 1614 COQUINA PLACE ATLANTIC BEACH FL 32233 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 169894 0010 ATLANTIC BEACH JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 338 7TH ST RESIDENTIAL ALTERATION RESIDENTIAL INTERIOR REMODEL $69000.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $356.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $178.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $8.01 STATE DCA SURCHARGE 455-0000-208-0600 0 $5.34 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 4/27/2021 PERMIT NUMBER RES21-0129 ISSUED: 4/27/2021 EXPIRES: 10/24/2021 RESIDENTIAL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 TOTAL: $547.35 2 of 2Issued Date: 4/27/2021 PERMIT NUMBER RES21-0129 ISSUED: 4/27/2021 EXPIRES: 10/24/2021 RESIDENTIAL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 RES21-0129 R E S 2 1 - 0 1 2 9 BOSSBALY RENOVATIONPETER COALSON DESIGN FOR FLORIDA LLC 904-759-2556 SITE PLAN N 1" =20-0" NO CHANGES TO SITE PLAN LOT COVERAGE ELECTRICAL CODE WIND SPEED 130 MPH IMPORTANCE FACTOR 1 TYPE OF CONST. OCCUPANCY CLASS Type V-B R-3 EXPOSURE C ENCLOSEDWIND EXPOSURE RISK LEVEL II BUILDING CODE REMODEL CATAGORY ALTERATION LEVEL 3 NATIONAL ELECTRICAL CODE 2014 GOVERNING CODES 7th Edition 2020 FLORIDA BUILDING CODE GENERAL NOTES: 1. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE PRIOR TO COMMENCING WORK. THE CONTRACTOR SHALL REPORT ALL DISCREPANCIES BETWEEN THE DRAWINGS AND EXISTING CONDITIONS TO THE DESIGNER & OWNER PRIOR TO COMMENCING WORK. 2. THE CONTRACTOR SHALL SUPPLY, LOCATE AND BUILD INTO THE WORK ALL INSERTS, ANCHORS, ANGLES, PLATES, OPENINGS, SLEEVES, HANGERS, SLAB DEPRESSIONS AND PITCHES AS MAY BE REQUIRED TO ATTACH AND ACCOMMODATE OTHER WORK. 3. ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE IN THE WORK EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN. 4. SUBSURFACE SOIL CONDITION INFORMATION IS NOT AVAILABLE. FOUNDATIONS ARE DESIGNED FOR A SOIL BEARING CAPACITY OF 3,000 PSF. THE CONTRACTOR SHALL REPORT ANY DIFFERING CONDITIONS TO THE DESIGNER & OWNER PRIOR TO COMMENCING WORK. 5. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB SPECIFICATION AND ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, AND SITE DRAWINGS, CONSULT THESE DRAWINGS FOR SLEEVES, DEPRESSIONS AND OTHER DETAILS NOT SHOWN ON STRUCTURAL DRAWINGS. 6. ALL BOLTS, NUTS, WASHERS, STRAPS AND FASTENERS INCLUDING NAILS, SHALL BE HOT DIP GALVANIZED OR STAINLESS STEEL. CONTINUOUS ANCHORAGE SHALL BE PROVIDED BETWEEN ALL TRUSSES, WALL SECTIONS, BEAMS, POSTS AND FOOTINGS WITH USE OF STRAPS AND CONNECTORS AS SPECIFIED HEREIN. 7. ALL SPECIFIED FASTENERS MAY ONLY BE SUBSTITUTED WITH DEVICE OF EQUAL OR GREATER CAPACITY. 8. THE INSTALLATION OF THE FASTENERS SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. WIND BRACING (1ST AND 2ND FLOORS) 4'- 0" X 8'-0" x 1/2" EXTERIOR GRADE PLYWOOD SIDING. NAIL 6" 0.C. FIELD AND EDGE. 19. THE STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE BUILDING IS COMPLETE. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND SEQUENCE TO ENSURE SAFETY OF THE BUILDING AND ITS COMPONENTS DURING ERECTION. THIS INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING, TEMPORARY BRACING, GUIDES, OR TIE DOWNS. INDEX OF DRAWINGS LOT 17 BLK 8 ONE STORY FRAME # 338 SEVENTH STREET 7TH STREET 40 ' RIGHT OF WAY SHEET 1 SHEET 2 SHEET 3 SHEET 4 SHEET 5 SITE PLAN EXISTING PLAN / DEMOLITION PLAN FLOOR PLAN MECHANICAL / ELECTRIC PLAN CABINET PLAN 4/16/2021 SHEET 1 NO CHANGE TO IMPERVIOUS COVERAGE FLORIDA BUILDING CODE 2020 RES21-0129 PETER COALSON DESIGN FOR FLORIDA LLC N DEMOLITION PLANEXISTING FLOOR PLAN REMOVE WALL REMOVE DOOR / WINDOW REMOVE CABINET/ APPLIANCE KITCHEN DINING FAMILY ROOM BEDROOM 1 BEDROOM 2 MASTER HALL BATH REF DUAL RANGE KNOOK DEMOLITION NOTES: DISCONNECT GAS SUPPLY DISABLE ALL BREAKERS SAVE ONE MARKED FOR TEMP POWER REMOVE ALL CEILING FIXATURES & FANS REMOVE ALL A/C & RA GRILLS ALL WALLS MARKED FOR REMOVAL ARE NON BEARING PROTECT OPENINGS WHERE WINDOWS AND DOORS ARE REMOVED REMOVE ALL DEBRIS DAILEY BROOM SWEEP SAVE WINDOWS AND DOORS REMOVED GARAGE KITCHEN DINING FAMILY ROOM MASTER HALL BATH REF DUAL RANGE GARAGE KNOOK BEDROOM 1 BEDROOM 2 20 6 0 S L I D I N G 20 6 0 S L I D I N G 20 6 0 S L I D I N G 60 6 8 S G D 60 6 8 S G D 3-O 3-O 3-O 6068 SGD 3- O 20 6 0 S L I D I N G 2060 SLIDING 50 6 8 S G D 3044 3044 SCALE 1/8" =1'-0"SCALE 1/8" =1'-0" BOSSBALY RENOVATION SH2 REMOVE TILE FLOORING / DINING AND KITCHEN REMOVE TILE HEARTH & SURROUND REMOVE ALLTILE FLOORING AND SETTING MATERIAL 4/16/2021 REMOVE FOYER TILE NO STRUCTRUAL CHANGES WH D W PETER COALSON DESIGN FOR FLORIDA LLC FLOOR PLAN WITHSCALE 1/8" = 1'-0" N FASTNERS EXPOSED EXTERIOR - STAINLESS BOSSBALY RENOVATION SH3 GARAGE KITCHEN FAMILY ROOM BEDROOM 1 BEDROOM 2 MASTER BEDROOM BATH NEW SHELVES (3) EACH SIDE OF FIREPLACE VAULTED CEILING EN T R Y D W HW REMOVE EXISTING MANTEL & TILE SURROUND REPLACE MANTEL ONLY REMOVE MED. CAB AND BATH FIXTURES REMOVE WINDOW AND INSTALL 2 NEW EGRESS WINDOWS REMOVE DOOR CLOSE OPENING OPTIONAL CEILING BEAM APPLY STUCCO TO EXTERIOR STUCCO EXTERIOR C L O S E T OHD DOOR TRACKS NEW2X4 WALL NEW ATIC ACCESS NEW DOOR / SIX PANEL STEEL NEW A/C GRILLS TYPICAL 1 REMOVE TEXTURING FROM ALL CEILINGS 2 SKIM CEILINGS 3 REMOVE & REPLACE ALL BASE & CASING 4 EXISTING DOORS REMAIN GENERAL NOTES: REMOVE SOFFIT INSTALL BOX FOR BRACKET LIGHT ON WALL 6-0 6-8 SLIDER FROM MASTER BEDROOM NEW CABINETS / ISLAND AND APPLIANCES BY OTHERS PA N T R Y NEW SHELVES NEW 2X4 WALL USE EXISTING CONNECTIONSRELOCATED WATER HEATER 51/2" NEW WIRE SHELVING RELOCATED 5" 2-8 2-8 DINING ROOM RELOCATE EXISTING A/C SUPPLY TO LAUNDRY ROOM PROVIDE & REPLCE TOILET RELOCATE GAS CONNECTION EXTEND NEW EXHAUST VENT AND PROVIDE NEW WALL FLANGE FRAME FOR EXHAUST VENT FRAMING SPECIFICATIONS CONCRETE SPECIFICATIONS 3000 PSI CONCRETE MIN.WITH REINFORCED FIBERMESH STUDE #2 SPF PLATES #2 SPF FASTNERS INTERIOR - GALVANIZED TROWEL FINISH, SMOOTH (3) 4/16/2021 (2 ) 3 0 5 0 W I T H M U L L ALUMNIUM MULL REMOVE SOFFIT. INSTALL BOX FOR BRACKET LIGHTS ON WALL (2) NEW ELECTRICAL OUTLETS O O O O O LOCATE AS REQUIRED FOR APPLIANCE NON STRUCTURAL CONCRETE FILL LINE OF EXISTING SLAB O O O NO STRUCTRUAL CHANGES HEATED SQUAR FOOTAGE 1,819SQ.FT. GARAGE SQUAR FOOTAGE 456 SQ.FT. 51/2" TREAT FOR TERMITS WHERE SOIL EXPOSED NEW FRENCH DOORS 30 30 36 " 36 " SELF CLOSSING 2-8 3'-10"6'-2" 1' - 4 " \ PETER COALSON DESIGN FOR FLORIDA LLC ELECTRICAL LIGHTING / MECHANICAL PLAN N BOSSBALY RENOVATION SH4 NEW 10" VENT PIPE CLOSE GAS SUPPLY FAN RELOCATE GAS CONNECTION R R R R R R R R R R FAN RELOCATED SUPPLY WH PRESSURE REPLACE GRILL TYPICAL REPLACE A/C GRILL TYPICAL R R R R UNDER CABINETUNDER CABINET REF DW SCALE 1/8" = 1'-0" 4/16/2021 S S S S S NOTE: ALL SMOKE DETECTORS COMBINATION CARBON DIXOIDE DETECTORS SS NEW TRIM ALL EXISTING RECESSED LIGHTS S S S SS S Co2 4"4" E EE E E E E E E EXISTING EXTERIOR FIXTURES EE S S S S S S S S S S S PETER COALSON DESIGN FOR FLORIDA LLC KITCHEN PLAN N BOSSBALY RENOVATION SH5 SCALE 1/2" = 1'-0" 2X8 KNEE WALL RELOCATED WASTE INSTALL STUTTER VENT RELOCATED GAS SUPPLY SUPPLY FOR REF. SEE SPECIFICATION CAP EXISTING WASTE 4/16/2021 BELOW COUNTER TOP CUT TRENCH EXISTING LINE UNDER CABINET LIGHTING UNDER CABINET LIGHT PRESSURE SWITCH DISPOSAL 12 " UPPER BELOW COUNTER 12 " UPPER BELOW COUNTER 12 " UPPER BELOW COUNTER DUEL FUEL RANGE C L REF FRAME AND DRYWALL BOX FOR EXHAUST VENT SEE MANUF. SPECIFICATION 7th Street 40' R W #338 Single Story Residence 15 0 ' 15 0 ' Construction Toilet in Residence MA T E R I A L S T O R A G E PARKING DU M P 50' 50' PETER COALSON DESIGN FOR FLORIDA LLC BOSSBALY INTERIOR RENOVATION 4/16/2021 SOLID FENCING SOLID FENCING SILT FENCE AS REQUIRED SITE MANAGEMENT PLAN SCALE 1" =1'-0" RES21-0129