Loading...
857 Bonita Rd Int Floor Plan Submittal -- Building Permit Application Updated 10/9/18 �� City of Atlantic Beach Building Department **ALL INFORMATION � V 800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY `•',.,91119,?' IS REQUIRED. Phone: (904) 247-5826 Email: Building-Dept@coab.us Job Address: 857 Bonita Road,Atlantic Beach,Florida,32233 Permit Number: Legal Description Lot#10,Block#3,Royal Palms RE# 171150 Valuation of Work(Replacement Cost)$ 128,000.00 Heated/Cooled SF 1,315 Non-Heated oled • Class of Work: ❑New ❑Addition VAlteration ❑Repair ElMove 6d Demo ❑Pool ❑Window/ r JUL 1 2 2021 1) • Use of existing/proposed structure(s): ❑Commercial SA Residential BY: • If an existing structure, is a fire sprinkler system installed?: ❑Yes IINo • Will tree(s) be removed in association with proposed proiect? ❑Yes(must submit separate Tree Removal Permit) V1No Describe in detail the type of work to be performed: interior floor plan modifications Florida Product Approval# for multiple products use product approval form Property Owner Information Name Dan&Linda Dunn Address 857 Bonita Road City Atlantic Beach State Florida Zip 32233 Phone 619-994-2754 E-Mail drdunn3@att.net Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) Contractor Information Name of Company Hagerty Construction&Roofing,Inc. Qualifying Agent Quin J. Hagerty Address 12850 Winthrop Cove Drive City Jacksonville State Florida Zip 32224 Office Phone 1-904-992-9960 Job Site Contact Number 1-904-591-4354 State Certification/Registration# CGC 019551 E-mail hagertyinc@yahoo.com Architect Name& Phone# Engineer's Name& Phone# Workers Compensation Insurer Zurich-American Insurance Company OR Exempt❑ Expiration Date 12/31/2021 Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies, or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER O' AN ATTORNEY BEFORE • - ti RDIRGYIOUR OTICE •F COMM NCEMENT. % r Y o ate• • I cat- 'L � �� z ' r 0 cc f tg.O nU (Signatu -of Owner or Agent) C ( ' ure of Contractor) o^`v W o�wr. 1 •" Po C7•1o� w.°�.inz =�,:S :, and sworn to(or affirmed)be'.re me this 12 day of Signed and •`•rn to • affirmed) before me this 12 day o &t• • 6c—c41 o Jul 2021 by ui Hagerty July 2021 by Tiffany Sral _ o.%.q —il.' z S.E. • Ili- Z p.•- o-� I I � � .i . E E m D r E T / (S g tv=!Notary) ignature o Notary) F g o 0 0' . C)e V U L.. O O . 00 Z x v 4 �� ''''. PersonallyKnown OR `e```:;*:,.:m .Wally Known OR [ o' . ., . Produced Identification ' ' .• ced Identification i i � "y& • ,i, ., I PHYSICALLY PRESENT Type of Identification: PHYSICALLY PRESENT °N. :C`` '�:; . dentification: YP Arm BBB MtOFthte WFAF61 Sf�P9f�0�16 CpItNAC1d1 MEMBER CONSTRUCTION 8� ROEOFING, INC. CERTIFIED GENERAL & ROOFING CONTRACTOR A+ RATING CGC 019551 - CCC 057779 July 12, 2021 City of Atlantic Beach Building Department Re: 857 Bonita Road I am submitting for a building permit to re-construct the interior of this home as per the attached plans. Therefore, In compliance with your request: 1. Hagerty Construction& Roofing, Inc. 12850 Winthrop Cove Drive Jacksonville, Florida,.32224 Quin J. Hagerty 1-904-992-9960 Certified General Contractor License#CGC-019551 2. 857 Bonita Road, Atlantic Beach, Florida, 32233 3. One Family Dwelling Method of Construction-Type II Alteration—Level 1 4. All trades, general, electrical, and plumbing will be using 7th. Edition of the Florida Bui8lding Code 5. (The existing air conditioning system will remain and will not be altered or updated) 6. There are two drawing submittals: A. the existing floor plan B. the proposed interior modifications floor plan 7. All drawings submittals have been fully dimensioned 8. There are no elevation alterations therefore, no exterior elevations have been provided 9. Please refer to#1, above. Page#1 of 2 Respectfully, Quin J. Hagerty, President Hagerty Construction & Roofing, Inc. 12850 WINTHROP COVE DRIVE-JACKSONVILLE-FLORIDA-32224 904-992-9960 office 904-992-9961 fax GAF President's CGC 019551 -CCC 057779 Club* hagertyinc@yahoo.com www.hagertyconstructionandroofinq.com Bronze si op, PROTECT YOUR INVESTMENT HIRE ONLY STATE LICENSED AND FULLY INSURED CONTRACTORS 2017—2018 - 2019 Page#2 of 2 CITY OF ATLANTIC BEACH •.tS�i 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 JV w (904)247-5800 BUILDING REVIEW COMMENTS Date: 7/6/2021 Permit#: DEM021-0021 Site Address:857 BONITA RD Review Status:Approved RE#: 171150 0000 Applicant: HAGERTY CONSTR.AND ROOFING Property Owner: DUNN, DAN & LINDA Email: HAGERTYINC@YAHOO.COM Email: DRDUNN3@ATT.NET Phone: 9049929960 Phone: 6199942754 THIS REVIEW IS ONE OF MULTIPLE DEPARTMENT REVIEWS. Revisions may not be submitted until ALL departments have completed their respective reviews. Revisions submitted MUST respond to EACH department review.Submittals that respond to only one or a few correction items will not be accepted. Correction Comments: 1. Submit a cover page for your business. A pdf will be attached for some guidelines as to what information is being requested. 2. From the 7th Edition of the 2020 FBC-Existing Building Code,choose a Method of Construction Compliance from Chapter 3,and a Classification of Work(alteration level) from Chapter 6. Place this information on your Cover page. 3. Other trades involved in this project will be responsible for pulling their own permits prior to them starting any work. 4. I have removed the existing and propose floor plans to reduce any confusion of this just being a demo permit for now. 5. When resubmitting the floor plans be sure to label each space's intended use, and dimensions. 6. If possible,please refer to Section R320 ACCESSIBILITY,R320.1.1, ...29 inch clear space for wheel chair egress in the fully furnished bathroom, for ground floor bathrooms. 7. Smoke alarms and carbon monoxide detectors up grades may be required if not already installed for a final building inspection. 8. Relocation of bathrooms may require mechanical ventilation issues if no windows are present. 9. Relocation of bathroom elements may also affect the need for tempered glass in existing windows if they require it. I am notifying the Permit Techs that even though I am sending you these review comments,to please approve the permit for Demo Only. Building Mike Jones Building Inspector/Plans Examiner City of Atlantic Beach Cover Page: 1. Contractor's Business name, Certificate/License#, address, phone contact, email address. 2. Address of project 3. Occupancy Class: For One &Two Family Dwellings 4. Applicable Codes and their currently used editions; building, plumbing, electrical, mechanical, fire prevention and COAB Code of Ordinances. 5. Energy forms as required by the Florida Energy Code. 6. Index of all drawings&attachments and all pages numbered. 7. Dimensions of all new additions, or internal reconfigurations and their new dimensions. 8. Elevations of the building that shows the affected changes areas. 9. Printed name, contact info,date and signature of person responsible for the design of the structure. I M'-07/16• 11'•017116' ......T-074', ,,•7714' 34' • 1• I• 6'--►4'2710... 1S-,.... 1'4....7.T.}�-4' 6'J117/1Y6' 6'-!1/16'---r h F -, I h N • X - i N y ri 777. —"— 7777— J L c y -�1211 1— 7777 — 7777— — 7777 , a C !i: 1OW—' a.t• I n aS Nj �� '- H 0 la 1 Y ❑ I 0 k I {t h_ _ 1 0 n 11 �.1/ Ii' Q_i 1.,:k qC a lO i yJ y /V. d{ .- i . T•11 514' h -�. ` ' 7777-/*417/1r"7777-"+ t ti 7' I� —J I LI IWI ' 1 ' N.ll !.,ss— ti t _. 551 BONITA ROAD EXISTING FLOOR PLAN l.:.W_. . ; •--------___L-77.......7777----___ 44'-0 7116' 1 I MEW 7-91 e_ T i 141 11/16- -. / tr N - _ i h • CoPorch /vered Open Po / \ Iv foray Room 1 I I 1 GENERAL NOTES ., II 7 �:t——•. I ^ I Provide&Insall Smote Detectors aro �5 I � Gerbon t-Wncalde Detectors m Per J'� --- 1 N' ith.Cdlttan of the 2020 FBG I11 In 1 d-t t 116"..n. 7 . pr .. b ` EM^9 'n j Install ventilators ventll a CrloSat ' m 1d• -2' III _ T device In queer tsthroo es MI' im Bedroom 4 I I ICI ` / -A fi A II�" I N p �" 11'-719/16" . "elf Doth NI • • I �Q� ¢ tiara^ it 1^ • b 7 O'41- 't , ', '4 / l e 9/6' KYuxr b 1 in I — - 1(1) jf I I h L.surNry 14'41 lir �S 1[... - 'I 5%0 1 1 1 Loi r T o LJ R 1920 ACCESSIBILITY 857 BO N ITA ROAD Ye1eel Chair Egress "Irlmum Clear 5p0:.c.2T PROPOSED INTERIOR MODIFICATIONS a_;• —....-...m A7 p_aMriisi wl___ • Apr.. BBB MätiFthte 4! wda�EMPPIPNORMcOMM MEMBER CONSTRUCTION & ROOFING. INC. ' CERTIFIED GENERAL & ROOFING CONTRACTOR A+ RATING CGC 019551 — CCC 057779 July 12, 2021 City of Atlantic Beach Building Department Re: 857 Bonita Road I am submitting for a building permit to re-construct the interior of this home as per the attached plans. Therefore, In compliance with your request: 1. Hagerty Construction & Roofing, Inc. 12850 Winthrop Cove Drive Jacksonville, Florida,.32224 Quin J. Hagerty 1-904-992-9960 Certified General Contractor License#CGC-019551 2. 857 Bonita Road, Atlantic Beach, Florida, 32233 3. One Family Dwelling Method of Construction-Type II Alteration—Level 1 4. All trades, general, electrical, and plumbing will be using 7th. Edition of the Florida Bui8lding Code 5. (The existing air conditioning system will remain and will not be altered or updated) 6. There are two drawing submittals: A. the existing floor plan B. the proposed interior modifications floor plan 7. All drawings submittals have been fully dimensioned 8. There are no elevation alterations therefore, no exterior elevations have been provided 9. Please refer to#1, above. Page#1 of 2 Respectfully, Quin J. Hagerty, President Hagerty Construction & Roofing, Inc. 12850 WINTHROP COVE DRIVE-JACKSONVILLE-FLORIDA-32224 904-992-9960 office 904-992-9961 fax GAF President's CGC 019551 -CCC 057779 Club* hagertyinc@yahoo.com www.hagertyconstructionandroofing.com Bronze �v PROTECT YOUR INVESTMENT ///r ti"i,i \".`l`�y�, HIRE ONLY STATE LICENSED AND FULLY INSURED CONTRACTORS 2017-2018 - 2019 Page#2 of 2 ,- i 1r x ,' CITY OF ATLANTIC BEACH kA J 800 SEMINOLE ROAD �; sa •> ATLANTIC BEACH,FL 32233 \ <' (904)247-5800 BUILDING REVIEW COMMENTS Date: 7/6/2021 Permit#: DEM021-0021 Site Address:857 BONITA RD Review Status:Approved RE#: 171150 0000 Applicant: HAGERTY CONSTR.AND ROOFING Property Owner: DUNN, DAN & LINDA Email: HAGERTYINC@YAHOO.COM Email: DRDUNN3@ATT.NET Phone: 9049929960 Phone: 6199942754 THIS REVIEW IS ONE OF MULTIPLE DEPARTMENT REVIEWS. Revisions may not be submitted until ALL departments have completed their respective reviews. Revisions submitted MUST respond to EACH department review.Submittals that respond to only one or a few correction items will not be accepted. Correction Comments: 1. Submit a cover page for your business. A pdf will be attached for some guidelines as to what information is being requested. 2. From the 7th Edition of the 2020 FBC-Existing Building Code, choose a Method of Construction Compliance from Chapter 3, and a Classification of Work(alteration level) from Chapter 6. Place this information on your Cover page. 3. Other trades involved in this project will be responsible for pulling their own permits prior to them starting any work. 4. I have removed the existing and propose floor plans to reduce any confusion of this just being a demo permit for now. 5. When resubmitting the floor plans be sure to label each space's intended use, and dimensions. 6. If possible,please refer to Section R320 ACCESSIBILITY,R320.1.1, ...29 inch clear space for wheel chair egress in the fully furnished bathroom, for ground floor bathrooms. 7. Smoke alarms and carbon monoxide detectors up grades may be required if not already installed for a final building inspection. 8. Relocation of bathrooms may require mechanical ventilation issues if no windows are present. 9. Relocation of bathroom elements may also affect the need for tempered glass in existing windows if they require it. I am notifying the Permit Techs that even though I am sending you these review comments,to please approve the permit for Demo Only. Building Mike Jones Building Inspector/Plans Examiner City of Atlantic Beach Cover Page: 1. Contractor's Business name,Certificate/License t#,address, phone contact, email address. 2. Address of project 3. Occupancy Class: For One &Two Family Dwellings 4. Applicable Codes and their currently used editions; building, plumbing, electrical, mechanical, fire prevention and COAB Code of Ordinances. 5. Energy forms as required by the Florida Energy Code. 6. Index of all drawings& attachments and all pages numbered. 7. Dimensions of all new additions, or internal reconfigurations and their new dimensions. 8. Elevations of the building that shows the affected changes areas. 9. Printed name, contact info,date and signature of person responsible for the design of the structure. 1 44'0-me- - 6''S?�_ --11'�O I5/16• Y•77/A" r 14' 105/1 1']"�„r." 1'67/4' 3--.,.-._-L�._-5' 4'4 sir- 7.4 4' 6'•115/16" 4' V.,51/11e . h I 2.- .5 • b I h I Nh II �I 1----C11 5 I' 1 I 4 I y h' w - in a 1 �- r1 i...- _�� as e a g N._- h N I:I! 1.-.--,tri C ''' i r.n 5/, sTO env-- 4 WIIIII 4 1 - I - ._6'.,5/e-•\-�o- - 1 r I ..._. II I } h 4 P. :LJ 851 BONITA ROAD EXISTING FLOOR PLAN I-,. 6 a • . r . I 44'-0 1(1o• - t --�M I 7-9117 � ,..` • in I — b' z7,1 ---- ---141 11116•— iir h I hi I N Covered Open Porch /•\ Family Room I I I GENERAL NOTES a J' L -. "®ratitii _ - - — Provide b I.'- Smoke DeteCas and I^-.5,_,- � I Gabon Monoxide Detectors n Par �iJ Gued sitI h� 1th.Edition of the 1010 FBG ii V.117M" Bathroo b Living Room 0 I in tr ■ d ), I natal)Ir 4 mechanical bathrventilaoom r; I i b to I device In guest bathroom ,d•7 m - t1 __A 63(0_, I .- 16'-T I n r-- u , . o ...9 II II 6 µ b k "aster Bedroom R., G 4 -I {.. ~-- 111/11_ iv-,istw, m Me Doth - }} I -J� _- m (/ �-}9'6 SW -4Kitchen in h Laundry 14.1111D• y i : A ._. 1 II1e f� _, _ • I T ..._ �. T - . gyir r _ Choir 857 BONITA ROAD Meet Minimum Clem Space-1a PROPOSED INTERIOR MODIFICATIONS t