487 Royal Palms Dr RES21-0072 7.19.21 Revision Submittal r ,?ii
Revision Request/Correction to Comments **ALL INFORMATION
HIGHLIGHTED IN
City of Atlantic Beach Building Department GRAY IS REQUIRED.
/,, 800 Seminole Rd, Atlantic Beach, FL 32233
Phone: (904) 247-5826 Email: Building-Deot@coab.us PERMIT#: RES21-0072
riRevision to Issued Permit OR El Corrections to Comments Date: 7/19/21
Project Address: 487 Royal Palms Drive
Contractor/Contact Name: Maureen Lamar EC IV�
Contact Phone: 404-735-9773 Email: mlamar217@icloud.com JUL ' 9 2021
Description of Proposed Revision/Corrections: BY:
Resubmitted signed Florida Energy Efficiency Code for Building Construction and Energy Performance Level Display Card
1 Maureen Lamar affirm the revision/correction to comments is inclusive of the proposed changes.
(printed name)
• Will proposed revision/corrections add additional square footage to original submittal?
ENo ED Yes (additional s.f. to be added: )
• ill proposed revision/corrections add additional increase in building value to original submittal?
11No Q*Yes (additional increase in building val'e:$ 70000 AI ) (Contractor must sign if increase in valuation)
/ /7 /
*Signature of Contractor/Agent: /
(Of ice Use Only)
11 Approved J Denied C Not Applicable to Department Permit Fee Due$
Revision/Plan Review Comments
Department Review Required:
Building
Planning & Zoning Reviewed By
Tree Administrator
Public Works
Public Utilities
Public Safety Date
Fire Services Updated 10/17/18
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 76
The lower the EnergyPerformance Index, the more efficient the home.
487 Royal Palms Drive, Atlantic Beach, FL,
1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area
2. Single family or multiple family Detached a. Face Brick-Wood, Exterior R=13.0 1206.00 ft2
b. N/A R= ft2
3. Number of units, if multiple family 1 c. N/A R= ft2
4. Number of Bedrooms 3 d. N/A R= ft2
11.Ceiling Type and insulation level Insulation Area
5. Is this a worst case? No a. Roof Deck(Unvented) R=22.0 1096.00 ft2
6. Conditioned floor area(ft2) 1096 b. Knee Wall(Unvented) R=0.0 67.60 ft2
7. Windows- Description Area c. N/A R= ft2
a. U Factor: Dbl, U=0.33 199.50 ft2 12. Ducts,location& insulation level R ft2
a. Sup:Attic, Ret:Attic,AH:Main 6 219.2
SHGC: SHGC=0.20
b. U-Factor: N/A ft2
SHGC: 13. Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ft2 a. Central Unit 24.0 SEER:14.00
SHGC:
d. U-Factor: N/A ft2
14. Heating systems kBtu/hr Efficiency
SHGC: a. Electric Heat Pump 24.0 HSPF:8.50
Area Weighted Average Overhang Depth: 1.333 ft.
Area Weighted Average SHGC: 0.200
8. Skylights Description Area 15. Hot water systems
a. U-Factor(AVG): N/A ft2 a. Propane Cap: 1 gallons
EF:0.86
SHGC(AVG): N/A
b. Conservation features
9. Floor Types Insulation Area None
a. Slab-On-Grade Edge Insulation R=0.0 1096.00 ft2 Credits(Performance method) Pstat
b. N/A R= ft2
c. N/A R= ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building .- .,
Construction through the above energysavingfeatures which will be installed (or exceeded) v's'''H''4"'I s•:,..
in this home before fi al inspection. Otherwise, a new EPL Display Card will be completed
'<v�`•%.40.' = �:n'
based on installed t%..e compliant featuro: '
7 q : a o;
Builder Signatur:. I �� Date: ���� 10 ,
. G ill °
Address of New Home / / 1* City/FL Zip: \..4y yk"
- '•.,COD wE�J•"
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
6/30/2021 11:35 AM 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 1 of 1
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: LAMAR1096 Builder Name: Lamar Residential Construction
Street: 487 Royal Palms Drive Permit Office: City of Atlantic Beach
City, State,Zip: Atlantic Beach , FL, Permit Number:
Owner: Jurisdiction: 261100
Design Location: FL, Jacksonville County: Duval(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 10. Wall Type$1206.0 sqft.) Insulation Area
2. Single family or multiple family Detached a. Face Brick-Wood, Exterior R=13.0 1206.00 ft2
b. N/A R= ft2
3. Number of units, if multiple family 1 c. N/A R= ft2
4. Number of Bedrooms 3 d. N/A R= ff2
5. Is this a worst case? No 11.Ceiling Types (1163.6 sqft.) Insulation Area
a. Roof Deck(Unvented) R=22.0 1096.00 ft2
6. Conditioned floor area above grade(ft2) 1096 b. Knee Wall(Unvented) R=0.0 67.60 ft2
Conditioned floor area below grade(ft2) 0 c. N/A R= ft2
7. Windows(199.5 sgft.) Description Area 12. Ducts R ft2
a Sup:Attic,Ret:Attic, AH:Main 6 219.2
a. U-Factor: Dbl,U=0.33 199.50 ft2
SHGC: SHGC=0.20
b. U-Factor: N/A ft2 13.Cooling systems kBtu/hr Efficiency
SHGC: a.Central Unit 24.0 SEER:14.00
c. U-Factor: N/A ff2
SHGC:
Area Weighted Average Overhang Depth: 1.333 ft. 14. Heating systems kBtu/hr Efficiency
Area Weighted Average SHGC: 0.200 a. Electric Heat Pump 24.0 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ft2 15. Hot water systems
SHGC(AVG): N/A a. Propane Tankless Cap: 1 gallons
9. Floor Types (1096.0 sgft.) Insulation Area EF:0.860
a.Slab-On-Grade Edge Insulation R=0.0 1096.00 ft2 b. Conservation features
b. N/A R= ft2 None
c. N/A R= ft2 16.Credits Pstat
Total Proposed Modified Loads: 27.40 PASS
Glass/Floor Area: 0.182
Total Baseline Loads: 35.97
'�,.. ..........
I hereby certify that the plans and specifications covered by Review of the plans and ,,:.O.TF1E S.r41'N.,.
��
this calculation are in compliance with the Florida Energy specifications covered by this v s 4 O
Code. calculation indicates compliancey
Digitally signed by Douglas R. 4R; a` ss�t,� 1
Douglas R.Stickles sad�s with the Florida Energy Code. ,<:rt,., r� ...N,,;,0�
PREPARED BY: Date:2°2'D'D21123D7-04'00' Before construction is completed a --- .""--• „ _ : - t'
DATE: this building will be inspected for I .c :a c
compliance with Section 553.908 ` .... two
gcomplianceFlorida Statutes. '......4#.4;'• :, ,.,����C r�
I herebycertifythat t . building, as deli ne►, is in o-
with the Florida En- i Cod-. `, ••.,SOD um lit-.f•
OWNE �, ' A /,Ili ._IL 1L/ /- BUILDING OFFICIAL: •••».."•. r
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2).
6/30/2021 11:35 AM 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 1 of 4