Loading...
91 Stanley Rd ROOF21-0050OWNER:ADDRESS:CITY:STATE:ZIP: K&D Mactavish LLC 62 Jefferson Avenue Ponte Vedra Beach FL 32082 COMPANY:ADDRESS:CITY:STATE:ZIP: Ecobuild Group Inc.1850 Wambolt St #5A Jacksonville Fl 32202 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 172188 0000 DONNERS R/P JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 91 STANLEY RD ROOF NON SHINGLE TOURCHED DOWN ROOF $10000.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 BUILDING ROOF IN-PROGRESS INSPECTION REQUIRED INFORMATIONAL Notes: a. The roof sheathing for all new construction must remain uncovered until the Roof Sheathing Inspection is approved. b. All roofing projects require an In-Progress Inspection. c. Sheathing installation and replacement guidelines per APA. d. Underlayment must conform to FBC-R Table 905.1.1 e. Shingles must conform to ASTM D3161 G or H, or ASTM D7158 F NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 7/27/2021 PERMIT NUMBER ROOF21-0050 ISSUED: 7/27/2021 EXPIRES: 1/23/2022 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $105.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $52.50 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.36 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $161.86 2 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL Notes: Roll off container company must be on City approved list. Approved list can be obtained at the Building Department at City Hall. Roll off container cannot be placed on City right-of-way. 2 of 2Issued Date: 7/27/2021 PERMIT NUMBER ROOF21-0050 ISSUED: 7/27/2021 EXPIRES: 1/23/2022 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 DESCRIPTION ACCOUNT QTY PAID PermitTRAK $161.86 ROOF21-0050 Address: 91 STANLEY RD APN: 172188 0000 $161.86 BUILDING $105.00 BUILDING PERMIT 455-0000-322-1000 0 $105.00 BUILDING PLAN REVIEW $52.50 BUILDING PLAN CHECK 455-0000-322-1001 0 $52.50 STATE SURCHARGES $4.36 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.36 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL FEES PAID BY RECEIPT: R16447 $161.86 Printed: Tuesday, July 27, 2021 4:05 PM Date Paid: Tuesday, July 27, 2021 Paid By: Ecobuild Group Inc. Pay Method: CREDIT CARD 488001035 1 of 1 Cashier: CG Cash Register Receipt City of Atlantic Beach Receipt Number R16447 Final Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: _____________________________________________________ Permit Type ____________________________________________________ Permit No. __________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION ROOF21-0050 ROOF21-0050 NEMO|etc. NEMO ETC, LLC Evaluation Report C40710.12.13-R8 for FL16709-R8 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 8: 03/15/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 1 of 25 APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE TABLE DECK APPLICATION TYPE DESCRIPTION PAGE 2A Roof Cladding Design Pressures, Allowable Stress Design, Pasd, Exposure B 3 2A Roof Cladding Design Pressures, Allowable Stress Design, Pasd, Exposure C 4 2A Roof Cladding Design Pressures, Allowable Stress Design, Pasd, Exposure D 5 3 Wood New or Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 6-9 4 Wood New, Reroof (Tear-Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 10-13 5 Wood New, Reroof (Tear-Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 14-17 6 Wood New, Reroof (Tear-Off) E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 18-21 7 Wood New, Reroof (Tear-Off) E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 22-25 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 2. Unless otherwise noted, insulation may be any one layer or combination of FBC Approved (Local or Statewide) board(s) that meet FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. 3. For adhered roof insulation and board-size: Unless otherwise noted, refer to Section 2.2.10.6.2 of FM Loss Prevention Data Sheet 1-29 (February 2020). 4. The maximum design pressure for the selected base assembly shall meet or exceed the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. This is already addressed in the tables that follow via “N/A” reference if the baseline system is “Not Applicable” to Zone 1 PRIME design pressure requirements. 5. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 6. Refer to FBC 1511 for requirements and limitations regarding recover installations. For Recover Applications using System Type D, the insulation is optional. 7. Unless otherwise noted, refer to the following references for bonded applications. TABLE 1: MEMBRANE / ADHESIVE COMBINATIONS REFERENCE LAYER MATERIAL APPLICATION BP-AA (Base and Ply sheets, Asphalt- Applied) Base Ply: Glasbase; All Weather/Empire Base, Flexiglas Base, Flintlastic Base 20 Hot asphalt at 20-40 lbs/square Ply: One or more Flintglas Ply 4, Flintglas Premium Ply 6 SBS-AA (SBS, Asphalt-Applied) Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base, Flintlastic Ultra Poly SMS Base Hot asphalt at 20-40 lbs/square Ply: One or more Flintlastic Base 20, Flintlastic Poly SMS Base, Flintlastic Ultra Poly SMS Base Cap Ply: Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS, Flintlastic GMS CoolStar SBS-TA (SBS, Torch-Applied) Base Ply: Flintlastic Ultra Poly SMS Base, Flintlastic Base 20 T Torch-Applied Ply: One or more Flintlastic Ultra Poly SMS Base, Flintlastic Base 20 T Cap Ply: Flintlastic FR Cap 30 T, Flintlastic FR Cap 30 T CoolStar ROOF21-0050 NEMO|etc. NEMO ETC, LLC Evaluation Report C40710.12.13-R8 for FL16709-R8 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 8: 03/15/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 2 of 25 TABLE 1 (CONTINUED): MEMBRANE / ADHESIVE COMBINATIONS REFERENCE LAYER MATERIAL APPLICATION APP-TA (APP, Torch-Applied) Base Ply: One or more Flintlastic APP Base T, Flintlastic STA, Flintlastic STA Plus Torch-Applied Cap Ply: Flintlastic STA, Flintlastic STA Plus, Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR, Flintlastic GTA-FR CoolStar SBS-SA (SBS, Self-Adhering) Base Ply: Flintlastic SA PlyBase, Flintlastic SA Mid Ply Self-Adhering Ply: Flintlastic SA PlyBase, Flintlastic SA Mid Ply Cap Ply: Flintlastic SA Cap, Flintlastic SA Cap CoolStar, Flintlastic SA Cap FR, Flintlastic SA Cap FR CoolStar 8. ”MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. 9. The following summary is the basis for the attachment tables herein. Tables 2A through 2C assume the following design parameters as defined in ASCE 7-16. Projects outside these design parameters are not applicable for use within the confines of this Evaluation Report. PARAMETER REFERENCE SYMBOL VALUE Design wind speed (mph)* FBC 1609.3 Vult Various Exposure Category FBC 1609.4.3 N/A B, C or D Topographical factor Section 26.8.2 Kzt 1.0 Wind directionality factor Section 26.6 Kd 0.85 Ground elevation factor Table 26.9-1 Ke 1.0 Roof slope N/A  < 7° *Selection of the appropriate design wind speed and exposure category is the responsibility of the user, subject to acceptance by the Authority Having Jurisdiction. NEMO|etc. NEMO ETC, LLC Evaluation Report C40710.12.13-R8 for FL16709-R8 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 8: 03/15/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 22 of 25 TABLE 7: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER “N/A” INDICATES THE SYSTEM CANNOT BE USED WITHIN THE PRESSURE ZONE. System No. Deck (Note 1) Base Sheet Roof Cover (Note 7) MDP (psf) Base Fasteners Attachment Base Ply and/or Ply Cap W-5 Min. 19/32-inch plywood Glasbase; Flexiglas; Flintlastic Base 20; All Weather / Empire Base; Poly SMS Base; Ultra Poly SMS Base; Yosemite 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails Pattern #1: 8-inch o.c. at the 4-inch side laps and 8-inch o.c. at three (3) equally spaced center rows BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -60.0 BASE SHEET ATTACHMENT PATTERN REFERENCES: PATTERN NO: #1 (AS-LISTED) #2 #3 #4 #5 #6 #7 MIN. LAP WIDTH (inch): 4 4 4 4 4 4 4 MAX. LAP FASTENER SPACING (inch o.c.): 8 7 6 6 6 4 4 MIN. # OF EQUALLY SPACED CENTER ROWS: 3 3 3 4 5 4 5 MAX. CENTER ROW FASTENER SPACING (inch o.c.): 8 7 6 6 6 4 4 BASE SHEET ATTACHMENT, SYSTEM W-5: Exposure Enclosure Roof Height (ft) Zone Ultimate Design Wind Speed – Vult (mph) 110 120 130 140 150 160 170 180 200 B Open h < 15 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #3 #5 15 < h < 20 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #6 20 < h < 30 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #2 #5 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #5 #7 30 < h < 40 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #5 #6 N/A NEMO|etc. NEMO ETC, LLC Evaluation Report C40710.12.13-R8 for FL16709-R8 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 8: 03/15/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 23 of 25 BASE SHEET ATTACHMENT, SYSTEM W-5: Exposure Enclosure Roof Height (ft) Zone Ultimate Design Wind Speed – Vult (mph) 110 120 130 140 150 160 170 180 200 B Enclosed h < 15 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #6 15 < h < 20 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #3 #5 #7 20 < h < 30 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #3 #5 #6 #7 30 < h < 40 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #5 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #5 #7 N/A C Open h < 15 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #6 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #3 #5 #6 #7 N/A 15 < h < 20 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #3 #5 #7 3 #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #5 #7 #7 N/A 20 < h < 30 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #5 #7 3 #1 (AS-LISTED) #1 (AS-LISTED) #3 #4 #5 #6 #7 N/A N/A 30 < h < 40 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #5 #6 #7 3 #1 (AS-LISTED) #2 #3 #5 #5 #7 #7 N/A N/A NEMO|etc. NEMO ETC, LLC Evaluation Report C40710.12.13-R8 for FL16709-R8 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 8: 03/15/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 24 of 25 BASE SHEET ATTACHMENT, SYSTEM W-5: Exposure Enclosure Roof Height (ft) Zone Ultimate Design Wind Speed – Vult (mph) 110 120 130 140 150 160 170 180 200 C Enclosed h < 15 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #2 #5 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #3 #5 #7 3 #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #5 #7 #7 N/A 15 < h < 20 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #5 #7 3 #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #6 #7 N/A N/A 20 < h < 30 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #3 #5 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #5 #6 N/A 3 #1 (AS-LISTED) #2 #3 #5 #5 #7 #7 N/A N/A 30 < h < 40 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #6 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #5 #7 N/A 3 #1 (AS-LISTED) #2 #3 #5 #6 #7 N/A N/A N/A D Open h < 15 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #3 #5 #6 #7 3 #1 (AS-LISTED) #2 #3 #5 #5 #7 #7 N/A N/A 15 < h < 20 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #3 #5 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #5 #7 N/A 3 #1 (AS-LISTED) #2 #3 #5 #6 #7 N/A N/A N/A 20 < h < 30 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #6 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #6 #7 N/A 3 #1 (AS-LISTED) #3 #4 #5 #7 #7 N/A N/A N/A 30 < h < 40 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #3 #5 #7 2 #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #5 #7 #7 N/A 3 #2 #3 #5 #6 #7 N/A N/A N/A N/A NEMO|etc. NEMO ETC, LLC Evaluation Report C40710.12.13-R8 for FL16709-R8 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 8: 03/15/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 25 of 25 BASE SHEET ATTACHMENT, SYSTEM W-5: Exposure Enclosure Roof Height (ft) Zone Ultimate Design Wind Speed – Vult (mph) 110 120 130 140 150 160 170 180 200 D Enclosed h < 15 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #6 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #5 #7 N/A 3 #1 (AS-LISTED) #2 #3 #5 #6 #7 N/A N/A N/A 15 < h < 20 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #7 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #3 #5 #6 #7 N/A 3 #1 (AS-LISTED) #3 #4 #5 #7 #7 N/A N/A N/A 20 < h < 30 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #5 #7 2 #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #5 #7 #7 N/A 3 #2 #3 #5 #6 #7 N/A N/A N/A N/A 30 < h < 40 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #5 #7 2 #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #6 #7 N/A N/A 3 #2 #3 #5 #7 #7 N/A N/A N/A N/A