Loading...
1772 Sea Oats Dr RESO21-0063 PergolaOWNER:ADDRESS:CITY:STATE:ZIP: SHERRILL PETER G 1772 SEA OATS DR ATLANTIC BEACH FL 32233-5829 COMPANY:ADDRESS:CITY:STATE:ZIP: IMPACT ENCLOSURES INC 11653 Central Parkway Jacksonville FL 32224 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 172020 0426 SELVA MARINA UNIT 08 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 1772 SEA OATS DR RESIDENTIAL OTHER SINGLE OR TWO FAMILY RESIDENTIAL OTHER PERGOLA ON POOL DECK $27400.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL Notes: All runoff must remain on-site during construction. 2 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL Notes: Roll off container company must be on City approved list. Approved list can be obtained at the Building Department at City Hall. Roll off container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 8/4/2021 PERMIT NUMBER RESO21-0063 ISSUED: 8/4/2021 EXPIRES: 1/31/2022 RESIDENTIAL OTHER PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $190.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $95.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $4.28 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.85 TOTAL: $292.13 3 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration, including sod, is required. 4 PUBLIC WORKS RUNOFF INFORMATIONAL Notes: All runoff must remain on-site. Cannot raise lot elevation. 5 PUBLIC WORKS DECKING REMOVED INFORMATIONAL Notes: All old decking and debris must be removed from job site by Contractor. 6 PUBLIC WORKS INFRASTRUCTURE INFORMATIONAL Notes: Any damage done to infrastructure must be repaired by Contractor. 2 of 2Issued Date: 8/4/2021 PERMIT NUMBER RESO21-0063 ISSUED: 8/4/2021 EXPIRES: 1/31/2022 RESIDENTIAL OTHER PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 DESCRIPTION ACCOUNT QTY PAID PermitTRAK $292.13 RESO21-0063 Address: 1772 SEA OATS DR APN: 172020 0426 $292.13 BUILDING $190.00 BUILDING PERMIT 455-0000-322-1000 0 $190.00 BUILDING PLAN REVIEW $95.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $95.00 STATE SURCHARGES $7.13 STATE DBPR SURCHARGE 455-0000-208-0700 0 $4.28 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.85 TOTAL FEES PAID BY RECEIPT: R16510 $292.13 Printed: Wednesday, August 4, 2021 1:35 PM Date Paid: Wednesday, August 04, 2021 Paid By: IMPACT ENCLOSURES INC Pay Method: CREDIT CARD 492052602 1 of 1 Cashier: CG Cash Register Receipt City of Atlantic Beach Receipt Number R16510 Final Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: _____________________________________________________ Permit Type ____________________________________________________ Permit No. __________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION RESO21-0063 RESO21-0063 3 2 ' 7 " 20' 5" 5 2 ' 6 " Pergola22' 1 2 ' Setbacks taken from posts RESO21-0063 Top View Right ViewLeft View Front View 22' 0" 12' 0" 11' 0" 22' 0" 10' 0"9' 6" This item has been electronically signed and sealed by Harold W Coffield,PE on using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Harold W Coffield, PE 2743 Anniston Rd Jacksonville, FL 32246 904-571-7106 FL PE #50407 2020 Florida Building Code Category 1 Sherrill Residence 1772 Sea Oats Dr. Atlantic Beach FL 32233 Builder: Impact Enclosures Exposure: C Wind Zone: 120 mph Cedar Pergola 6x6 6x6 6x6 6x6 6x6 6x6 6 x 6 6 x 6 ( 2 ) 2 x 1 0 H e a d e r t y p (2 ) 2 x 1 0 H e a d e r t y p 2x8 Truss 16" O.C. typ 2x8 Truss 16" O.C. typ 2x6 Bracing typ Slat Walls Non-supporting typ 24' 0" 14' 1" DocuSign Envelope ID: AF587FE6-D1C8-49B7-B64D-4C6DD90B7C8A 6/8/2021 Pergola Detail Sheet 1 Harold W Coffield, PE 2743 Anniston Rd Jacksonville, FL 32246 904-571-7106 FL PE #50407 2020 Florida Building Code Category 1 DocuSign Envelope ID: AF587FE6-D1C8-49B7-B64D-4C6DD90B7C8A 5 Pergola Truss To Gutter/Host Pergola Detail Sheet 2 4 Pergola Truss To Host Existing Wall FramingNew Truss Fasten To Header w/ (3) #9 Deckmate Screws Per Side 2x8 Header Fastened To Wall 3/8"x8" Lag Bolts At 8" O.C. Staggered. Fasten New Header To Existing Top Plate/Wall Header Note: Pre-Drill Holes And Fill With Compatible Sealant Prior To Attaching Lag Bolts To Host Structure. Host Wood Truss 6 Post To Spot Footing Option (2) #5 Rebar Through Post in "X" Pattern 2500 PSI Concrete 2' 6"Stone Base Harold W Coffield, PE 2743 Anniston Rd Jacksonville, FL 32246 904-571-7106 FL PE #50407 2020 Florida Building Code Category 1 DocuSign Envelope ID: AF587FE6-D1C8-49B7-B64D-4C6DD90B7C8A Harold W Coffield, PE 2743 Anniston Rd Jacksonville, FL 32246 904-571-7106 FL PE #50407 2020 Florida Building Code Category 1 DocuSign Envelope ID: AF587FE6-D1C8-49B7-B64D-4C6DD90B7C8A NEW CONCRETE DETAIL SHEET 1 1 4” CONCRETE 2 4” CONCRETE W/ 6” EDGE 3 4” CONCRETE W/ 8”X8” FOOTING NEW CONCRETE 4” THICK 6” THICKENDED EDGE 3000 PSI NEW CONCRETE 4” THICK 6” THICKENDED EDGE 3000 PSI NEW CONCRETE 4” THICK 3000 PSI NEW CONCRETE 4” THICK 3000 PSI 4 12"X12" FOOTING W/ PAVERS NEW PAVERS12”X12” FOOTER WITH 1 #5 THRU OUT PAVERS NEW PAVERS 12”X12” FOOTER WITH 1 #5 THRU OUT 5 BLOCK STEM WALL & FOOTING ALUMINUM STRUCTURE 2"2" CMU BlOCK UP TO 42"H REBAR EXTENDING UP FROM FOOTING EVERY 4'. FILLED W/ CONCRETE #5 REBAR EMBEDDED IN CONCRETE ALONG TOP ROW OF BLOCK #5 "L" SHAPE REBAR EMBEDDED INTO FOOTING TURNED UP THRU CMU BLOCKS. 4’ SPACING (2) #5 REBAR ALONG FOOTING. SEATED 2" ABOVE BOTTOM OF FOOTNG 16" FOOTING 2500 PSI CONCRETE Up To 42" ALUMINUM STRUCTURE 2"2" CMU BlOCK UP TO 42"H REBAR EXTENDING UP FROM FOOTING EVERY 4'. FILLED W/ CONCRETE #5 REBAR EMBEDDED IN CONCRETE ALONG TOP ROW OF BLOCK #5 "L" SHAPE REBAR EMBEDDED INTO FOOTING TURNED UP THRU CMU BLOCKS. 4’ SPACING (2) #5 REBAR ALONG FOOTING. SEATED 2" ABOVE BOTTOM OF FOOTNG 16" FOOTING 2500 PSI CONCRETE Up To 42" 16" GRAD E 16" GRADE 6 RAISED SLAB OR PAVERS W/ BLOCK STEM WALL & FOOTING SLAB OR PAVERS 7 12"X12"X12" SPOT FOOTING #5 REBAR X PATTERN 12”X12”X12” POURED CONCRETE 3' 2' 2' P O S T 2500 PSI CONCRETE POST SUNKEN 24" INTO CONCRETE 9 SPOT FOOTING SUNKEN POST #5 REBAR X PATTERN 18”X18”X18” POURED CONCRETE 8 18"X18"X18" SPOT FOOTING Harold W Coffield, PE 2743 Anniston Rd Jacksonville, FL 32246 904-571-7106 FL PE #50407 NEW CONCRETE 4” THICK 8” Thickened Edge (1) #5 REBAR 3000 PSINEW CONCRETE 4” THICK 8" Thickened Edge (1) #5 REBAR 3000 PSI DocuSign Envelope ID: AF587FE6-D1C8-49B7-B64D-4C6DD90B7C8A