705 Atlantic Blvd SIGN21-0015 Makenu Chocolate Wall SignOWNER:ADDRESS:CITY:STATE:ZIP:
SEMINOLE SOUTH, LLC 2300 MARSH POINT RD, 301 NEPTUNE BEACH FL 32266
COMPANY:ADDRESS:CITY:STATE:ZIP:
HARBINGER SIGN CO 5300 Shad Rd JACKSONVILLE FL 32257
TYPE OF
CONSTRUCTION:
REAL ESTATE
NUMBER:ZONING:BUILDING USE
GROUP:SUBDIVISION:
170655 0000 SALTAIR SEC 01
JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK:
705 ATLANTIC BLVD SIGN WALL
22 Seminole wall sign conn.
to exist elec. MAKENU
CHOCOLATE
$2100.00
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
BLDG 2ND PLAN REVIEW FEE 455-0000-322-1006 0 $50.00
SIGN WITH OR WITHOUT ELECTRIC 455-0000-322-1000 18.4 $65.00
STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00
ZONING WALL SIGN FEE 001-0000-329-1003 0 $30.00
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN
YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT
MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU
INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT.
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
1 of 2Issued Date: 8/4/2021
PERMIT NUMBER
SIGN21-0015
ISSUED: 8/4/2021
EXPIRES: 1/31/2022
SIGN PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
TOTAL: $149.00
2 of 2Issued Date: 8/4/2021
PERMIT NUMBER
SIGN21-0015
ISSUED: 8/4/2021
EXPIRES: 1/31/2022
SIGN PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
DESCRIPTION ACCOUNT QTY PAID
PermitTRAK $149.00
SIGN21-0015 Address: 705 ATLANTIC BLVD APN: 170655 0000 $149.00
BLDG SUBSEQUENT PLAN REVIEW FEES $50.00
BLDG 2ND PLAN REVIEW FEE 455-0000-322-1006 0 $50.00
BUILDING $65.00
SIGN WITH OR WITHOUT ELECTRIC 455-0000-322-1000 18 $65.00
STATE SURCHARGES $4.00
STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00
ZONING PLAN REVIEW $30.00
ZONING WALL SIGN FEE 001-0000-329-1003 0 $30.00
TOTAL FEES PAID BY RECEIPT: R16518 $149.00
Printed: Wednesday, August 4, 2021 4:05 PM
Date Paid: Wednesday, August 04, 2021
Paid By: HARBINGER SIGN CO
Pay Method: CREDIT CARD 492286924
1 of 1
Cashier: CG
Cash Register Receipt
City of Atlantic Beach
Receipt Number
R16518
Final Plumbing
Final Electrical
Final HVAC
CC Final
Final Building*
Swimming Pool Steel
Swimming Pool Safety
Electrical Grounding & Bonding
Swimming Pool Final (Bldg)
Swimming Pool Final (PW)
Formed Columns/ Beams*
Masonry Cell Fill
Structural Steel*
OTHER:
OTHER:
OTHER:
OTHER:
OTHER:
Power Pole
Silt Fence
Piers/ Stem Walls
Underground Plumbing
Underground Electric
Foundation/ Footing
Slab**
Retaining Wall Footing
Driveway
Sewer (Building Dept)
Sewer Tap (Utilities Dept)
Rough Electric*
Rough Plumbing/ Top Out*
Rough Mechanical*
House Wrap
Wall Sheathing
Roof Sheathing
Tie-down Framing Connections
Rough Framing
Roofing In Progress
Window/Door In-Progress
Insulation Ceiling
Insulation Wall
Exterior Lath
Stucco Scratch Coat
Exterior Siding In-Progress
Brick Flashing & Ties
Early Power
Gas Rough
Gas Final*
* When all rough electric, plumbing, mechanical are complete but before any work is
covered up.
* When all gas piping is complete and wallboard is installed but before gas is
attached to any appliance. All outlets must be capped and pipe pressurized at a
minimum of 15 lbs.
* For new living space: When all construction work including electrical, plumbing,
mechanical, exterior finish, grading, required paving and landscaping is complete
and the building is ready for occupancy, but before being occupied
Additional inspections may apply to your project if your project
contains these elements:
INSPECTIONS REQUIRED FOR BUILDING PERMITS
To verify compliance with building codes, inspections of the work authorized are required at various points of the construction.
The following inspections are typically required for residential projects:
Date: Initial: Date: Initial:
_____________________________________________________
Permit Type
____________________________________________________
Permit No.
__________________________________________________________
Job Address
____________________________________________________
Contractor
POST THIS CARD WITH PERMITS AND PERMIT
DOCUMENTATION IN FRONT OF BUILDING
Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends
Building Department Public Works/Utilities Fire Department
Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789
Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203
* When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all
electrical, plumbing and mechanical work is in place, but before concrete is poured.
* When all structural steel members are in place and all connections are complete,
but before such work is covered or concealed.
** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
(904) 247-5800
MEMO
To: Plan Review
From: Dan Arlington
Subject: Sign installation
Date: May 25, 2016
In addition to meeting the Zoning requirements for size, location, and design, signs must comply with
the structural requirements of the Florida Building Code-Building. Construction documents must
show the dimensions, material, and required details of construction of the sign and supporting
structure, including loads, stresses, and anchors.
Permit applications for sign permits must include the following:
1. Design Criteria:
Wind speed: 130 mph (Vult), 101 mph (Vasd) Linear interpolation is permitted.
Wind Exposure Category: C or D
Building height.
Wind Design Pressures.
2. Total load on sign, including wind and gravity loads.
3. Wall material and wall section on which sign is installed. Show blocking where required.
4. Manufacturer’s data sheet for fasteners used.
5. Allowable load for each fastener and number of fasteners used.
1609.1.1 Determination of wind loads.
Wind loads on every building or structure shall be determined in accordance with Chapters 26 to 30 of
ASCE 7 or provisions of the alternate all-heights method in Section 1609.6. Wind shall be assumed to
come from any horizontal direction and wind pressures shall be assumed to act normal to the surface
considered.
Revision Request/Correction to Comments **ALL INFORMATION
HIGHLIGHTED IN
GRAY IS REQUIRED. City of Atlantic Beach Building Department
800 Seminole Rd, Atlantic Beach, FL 32233
Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT #: _____________________
Revision to Issued Permit OR Corrections to Comments Date: ________________
Project Address: ____________________________________________________________________________________
Contractor/Contact Name: ____________________________________________________________________________
Contact Phone: ______________________________ Email: _________________________________________________
Description of Proposed Revision / Corrections:
__________________________________________________________________________________________________
__________________________________________________________________________________________________
__________________________________________________________________________________________________
__________________________________________________________________________________________________
I_______________________________ affirm the revision/correction to comments is inclusive of the proposed changes.
(printed name)
Will proposed revision/corrections add additional square footage to original submittal?
No Yes (additional s.f. to be added: _____________________________)
Will proposed revision/corrections add additional increase in building value to original submittal?
No *Yes (additional increase in building value: $____________________) (Contractor must sign if increase in valuation)
*Signature of Contractor/Agent: _______________________________________________________
__________________________________________________________________________________________________
(Office Use Only)
Approved Denied Not Applicable to Department Permit Fee Due $_______________
Revision/Plan Review Comments_______________________________________________________________________
__________________________________________________________________________________________________
Department Review Required:
Building _____________________________________________
Planning & Zoning Reviewed By
Tree Administrator
Public Works
Public Utilities _____________________________________________
Public Safety Date
Fire Services Updated 10/17/18
EXTERIOR WALL SIGN
30 SEMINOLE BLVD. ATLANTIC BEACH, FL
REVISED 05.19.2021
PAGE ORDER
1. TITLE PAGE
2. DESIGNS
3. SITE PLAN
ALLOWED TOTAL
PROPOSED TOTAL
5300 Shad Road, Jacksonville, FL. 32257
PROJECT MGR: Mike Lev
DESIGNER: Brandon Winebarger
DATE REV.DESCRIPTION
1PAGE
SQUARE FOOTAGE FORMULA
ZONING: COMMERCIAL
SALES ASSOC: Ed Busey
03.05.21
03.16.21
03.25.21
05.19.21
00
R1
R2
R3
Original
Show customer more options per requests
Add 4th Option
Create permit ready artwork, and reduce size
INITIALS
CALCULATIONS:
Approved
Approved as Noted
Not Approved
Customer Signature:
Date:
Customer Notes:
FILE: MAK_WAL_R3
PATH: F:\Customers\F:\MAKENU CHOCOLATE_MAK\WALL SIGN\2. DESIGNS\3. CDR
CUSTOMER APPROVAL:
harbingersign.com 904.268.4681
BW
BW
JO
gh
ONE (1) SQUARE FOOT OF SIGN FACE AREA FOR EACH
LINEAR FOOT OF BUILDING FOR THE OCCUPANT OR
TENANT SPACE IN A MULTI-TENANT DEVELOPMENT, EACH
AS MEASURED ON THE STREET TOWARD WHICH THE
FASCIA SIGN IS ORIENTED. IN NO CASE SHALL AN
INDIVIDUAL FASCIA SIGN EXCEED ONE HUNDRED (100)
SQUARE FEET OF SIGN FACE AREA NOR SHALL THE
COMBINED SIGNAGE FOR ONE (1) OCCUPANT EXCEED
TWO HUNDRED (200) SQUARE FEET OF SIGN FACE AREA.
1 SQFT X 18.7 FT OF LINEAR FOOT OF WALL = 18.7 SQFT
Exterior Wall Sign (DAY VIEW)
3/4” = 1’-0”
QTY (1) EA
ONE (1) NEW 4” DEEP REMOTE FACE-LIT 3/16” ACRYLIC CHANNEL LETTERS MOUNTED ON 8” RACEWAY WITH “CHOCOLATE” 1” PUSH-THU
ACRYLIC LETTERS. 4” DEEP ALUMINUM RETURNS PAINTED PANTONE COOL GRAY 11C . 1” COOL GRAY (JEWELITE) TRIM CAP.
LETTERS & RACEWAY TO BE INTERNALLY ILLUMINATED W/ WHITE LEDS .
NOTE: HARBINGER TO SUPPLY NEW ALUM. ENCLOSURE SUPPORT FOR NEW EXTERIOR SIGN, SURVEY REQUIRED
S1 3/16” FLAT WHITE ACRYLIC
S2 4” DEEP ALUM. RETURNS
P1 PANTONE COOL GRAY 11C
Exterior Wall Sign (NIGHT VIEW)
NOT TOSCALE
QTY (1) EA
18.4 SQFT
OPTION D
S3 1” PUSH-THRU ACRYLIC
S4 ALUM. RACEWAY
P2 BLACK
S1
S2
P1
S3
S4
P2
NOTE: LOGO STROKE THICKNESS INCREASED TO MEET MANUFACTURING REQUIRMENTS
30 SEMINOLE BLVD.
ATLANTIC BEACH, FL
1D
18.7 SQFT
18.4 SQFT
96” OAL
5
3
/
1
6
”
1
8
7
/
1
6
”
2
7
3
/
8
’
MANSARD ROOF
EXISTING 1 1/2” X 1 1/2”
CEDAR SUPPORTS
EXISTING 5/8” THICK
PLYWOOD JOINING PLATES
(BOTH SIDES)
EXISITING BRICK WALL
THE STRUCTURAL DESIGN CONFORMS TO THE FOLLOWING CODES AND
SPECIFICATIONS: THE FLORIDA BUILDING CODE SEVENTH EDITION
(2020). THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (MANUAL
OF STEEL CONSTRUCTION, 9TH EDITION). THE AMERICAN WELDING
SOCIATY (AWS D1.1-15. THE AMERICAN CONCRETE INSTITUTE
BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI
318-14). THE SPECIFICATION FOR ALUMINUM STRUCTURES BY THE
ALUMINUM ASSOCIATION (CURRENT EDITION).
ALLOWED TOTAL
PROPOSED TOTAL
5300 Shad Road, Jacksonville, FL. 32257
PROJECT MGR: Mike Lev
DESIGNER: Brandon Winebarger
DATE REV.DESCRIPTION
2PAGE
SQUARE FOOTAGE FORMULA
ZONING: COMMERCIAL
SALES ASSOC: Ed Busey
03.05.21
03.16.21
03.25.21
05.19.21
00
R1
R2
R3
Original
Show customer more options per requests
Add 4th Option
Create permit ready artwork, and reduce size
INITIALS
CALCULATIONS:
Approved
Approved as Noted
Not Approved
Customer Signature:
Date:
Customer Notes:
FILE: MAK_WAL_R3
PATH: F:\Customers\F:\MAKENU CHOCOLATE_MAK\WALL SIGN\2. DESIGNS\3. CDR
CUSTOMER APPROVAL:
harbingersign.com 904.268.4681
BW
BW
JO
gh
ONE (1) SQUARE FOOT OF SIGN FACE AREA FOR EACH
LINEAR FOOT OF BUILDING FOR THE OCCUPANT OR
TENANT SPACE IN A MULTI-TENANT DEVELOPMENT, EACH
AS MEASURED ON THE STREET TOWARD WHICH THE
FASCIA SIGN IS ORIENTED. IN NO CASE SHALL AN
INDIVIDUAL FASCIA SIGN EXCEED ONE HUNDRED (100)
SQUARE FEET OF SIGN FACE AREA NOR SHALL THE
COMBINED SIGNAGE FOR ONE (1) OCCUPANT EXCEED
TWO HUNDRED (200) SQUARE FEET OF SIGN FACE AREA.
1 SQFT X 18.7 FT OF LINEAR FOOT OF WALL = 18.7 SQFT
Photo Overlay
NTS
NOTE: SURVEY REQUIRE OF EXISTING MANSARD ROOF/WALL AREA FOR PROPER CALCULATIONS AND INSTALL METHOD
OPTION D
30 SEMINOLE BLVD.
ATLANTIC BEACH, FL
1D
18.7 SQFT
18.4 SQFT
Photo Overlay
1/4” = 1’-0”1D
4’-0” PAN5’-0” V.O.6’-11 1/2” CUT SIZE7’-0” EXISTING CABINET4’-0” PAN5’-0” V.O.6’-11 1/2” CUT SIZE7’-0” EXISTING CABINET 4’-0” PAN5’-0” V.O.6’-11 1/2” CUT SIZE7’-0” EXISTING CABINET 4’-0” PAN5’-0” V.O.6’-11 1/2” CUT SIZE7’-0” EXISTING CABINET7PT DIMENSIONCALLOUTS 9PT DIMENSIONCALLOUTS 4’-0” PAN5’-0” V.O.6’-11 1/2” CUT SIZE7’-0” EXISTING CABINET9PT BUILDINGDIMENSIONCALLOUTS4’-0” PAN5’-0” V.O.6’-11 1/2” CUT SIZE7’-0” EXISTING CABINET
3
5
.
0
5
"
18'-8" (224”)
1
4
'
-
9
"
(1
7
7
”
)
96.00"
9
1
/
4
"
12'-7 1/2"
ABOVE GRADE
THE STRUCTURAL DESIGN CONFORMS TO THE FOLLOWING CODES AND
SPECIFICATIONS: THE FLORIDA BUILDING CODE SEVENTH EDITION
(2020). THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (MANUAL
OF STEEL CONSTRUCTION, 9TH EDITION). THE AMERICAN WELDING
SOCIATY (AWS D1.1-15. THE AMERICAN CONCRETE INSTITUTE
BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI
318-14). THE SPECIFICATION FOR ALUMINUM STRUCTURES BY THE
ALUMINUM ASSOCIATION (CURRENT EDITION).
ALLOWED TOTAL
PROPOSED TOTAL
5300 Shad Road, Jacksonville, FL. 32257
PROJECT MGR: Mike Lev
DESIGNER: Brandon Winebarger
DATE REV.DESCRIPTION
3PAGE
SQUARE FOOTAGE FORMULA
ZONING: COMMERCIAL
SALES ASSOC: Ed Busey
03.05.21
03.16.21
03.25.21
05.19.21
00
R1
R2
R3
Original
Show customer more options per requests
Add 4th Option
Create permit ready artwork, and reduce size
INITIALS
CALCULATIONS:
Approved
Approved as Noted
Not Approved
Customer Signature:
Date:
Customer Notes:
FILE: MAK_WAL_R3
PATH: F:\Customers\F:\MAKENU CHOCOLATE_MAK\WALL SIGN\2. DESIGNS\3. CDR
CUSTOMER APPROVAL:
harbingersign.com 904.268.4681
BW
BW
JO
gh
ONE (1) SQUARE FOOT OF SIGN FACE AREA FOR EACH
LINEAR FOOT OF BUILDING FOR THE OCCUPANT OR
TENANT SPACE IN A MULTI-TENANT DEVELOPMENT, EACH
AS MEASURED ON THE STREET TOWARD WHICH THE
FASCIA SIGN IS ORIENTED. IN NO CASE SHALL AN
INDIVIDUAL FASCIA SIGN EXCEED ONE HUNDRED (100)
SQUARE FEET OF SIGN FACE AREA NOR SHALL THE
COMBINED SIGNAGE FOR ONE (1) OCCUPANT EXCEED
TWO HUNDRED (200) SQUARE FEET OF SIGN FACE AREA.
1 SQFT X 18.7 FT OF LINEAR FOOT OF WALL = 18.7 SQFT
30 SEMINOLE BLVD.
ATLANTIC BEACH, FL
Site Overview
NTS
THE STRUCTURAL DESIGN CONFORMS TO THE FOLLOWING CODES AND
SPECIFICATIONS: THE FLORIDA BUILDING CODE SEVENTH EDITION
(2020). THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (MANUAL
OF STEEL CONSTRUCTION, 9TH EDITION). THE AMERICAN WELDING
SOCIATY (AWS D1.1-15. THE AMERICAN CONCRETE INSTITUTE
BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI
318-14). THE SPECIFICATION FOR ALUMINUM STRUCTURES BY THE
ALUMINUM ASSOCIATION (CURRENT EDITION).
ALLOWED TOTAL
PROPOSED TOTAL
5300 Shad Road, Jacksonville, FL. 32257
PROJECT MGR: Mike Lev
DESIGNER: Brandon Winebarger
DATE REV.DESCRIPTION
4PAGE
SQUARE FOOTAGE FORMULA
ZONING: COMMERCIAL
SALES ASSOC: Ed Busey
03.05.21
03.16.21
03.25.21
05.19.21
00
R1
R2
R3
Original
Show customer more options per requests
Add 4th Option
Create permit ready artwork, and reduce size
INITIALS
CALCULATIONS:
Approved
Approved as Noted
Not Approved
Customer Signature:
Date:
Customer Notes:
FILE: MAK_WAL_R3
PATH: F:\Customers\F:\MAKENU CHOCOLATE_MAK\WALL SIGN\2. DESIGNS\3. CDR
CUSTOMER APPROVAL:
harbingersign.com 904.268.4681
BW
BW
JO
gh
ONE (1) SQUARE FOOT OF SIGN FACE AREA FOR EACH
LINEAR FOOT OF BUILDING FOR THE OCCUPANT OR
TENANT SPACE IN A MULTI-TENANT DEVELOPMENT, EACH
AS MEASURED ON THE STREET TOWARD WHICH THE
FASCIA SIGN IS ORIENTED. IN NO CASE SHALL AN
INDIVIDUAL FASCIA SIGN EXCEED ONE HUNDRED (100)
SQUARE FEET OF SIGN FACE AREA NOR SHALL THE
COMBINED SIGNAGE FOR ONE (1) OCCUPANT EXCEED
TWO HUNDRED (200) SQUARE FEET OF SIGN FACE AREA.
1 SQFT X 18.7 FT OF LINEAR FOOT OF WALL = 18.7 SQFT
3/
8
"
S
S
L
A
G
B
O
L
T
S
I
N
T
O
R
A
F
T
E
R
O
R
I
N
T
O
M
I
N
.
2
"
SO
L
I
D
W
O
O
D
B
L
O
C
K
I
N
G
(
B
Y
O
T
H
E
R
S
)
O
R
3/
8
"
SS
TH
R
O
U
G
H
B
O
L
T
S
T
O
S
L
E
E
P
E
R
A
N
G
L
E
S
P
A
N
N
I
N
G
MI
N
.
2
R
A
F
T
E
R
S
EN
G
I
N
E
E
R
'
S
N
O
T
E
:
Al
l
t
h
r
o
u
g
h
b
o
l
t
s
i
n
c
o
n
t
a
c
t
w
i
t
h
a
l
u
m
i
n
u
m
t
o
b
e
s
t
a
i
n
l
e
s
s
s
t
e
e
l