665 SAILFISH DR ACC21-0036 BRYCE BROWNING GROUND WATER TABLE AND CALCULATIONS revision 7-7-21_1Comp. By: Date: Public Works Department City of Atlantic Beach Permit No:RES21-003 Address:665 Sailfish drive Required Storage Volume Criteria: Section 24-66 of the City of Atlantic Beach's Zoning, Subdivsion, and Land Development Regulations requires that stormwater runoff from impervious areas be stored onsite. Volume to be retained is as follows: V = CAR/12 which is the Modified Rational Method for estimating stormwater runoff Where: V = Volume of Runoff to be stored (cubic feet) C = Runoff Coefficient, 0.92, the difference between impervious area (C=1.0) and undeveloped conditions (C=0.08). A = Impervious Area (square feet) R= 25-yr / 24-hr rainfall depth (9.3 inches for Atlantic Beach) Onsite Storage Volume Required for Impervious Area: Lot Area = 7,500 ft2 Impervious Area (A) = 2,878 ft2 =38.4% V = 0.92 x 2,878.0 x 9.3 / 12 V = 2,052 ft3 Provided Storage: Area 1 - FRONT Area Storage Sideslope:4 :1 (ft)(ft2) (ft 3) 12.5 551 BOTTOM size:X 13.0 1,035 TOB size:X Area 2 - BACK Area Storage (ft)(ft2) (ft 3) 0.0 0 BOTTOM size:X 0.0 0 TOB size:X Area 3 - Relative Elev.Area Storage (ft)(ft2) (ft 3) 0.0 0 BOTTOM size:0 X 0 0.0 0 TOB size:0 X 0 Inground Storage: = A*d/pf Total Storage Area at TOB (A) =1035.0 ft2 Depth to ESHWT from BOTTOM (d) =4.5 ft, default is 2.0 ft, verify onsite ESHWT Pore Factor (pf) = 0.4 default is 0.4 Inground Storage Provided =1863.0 ft3 Required Treatment Volume =2,052 ft3 Supplied Treatment Volume =2,260 ft3 397 0 0 6/30/2021 Retention 380 Seminole Rd_Calcs 6/30/2021 ALPHA SOUTHEAST, INC. 2670 ROSSELLE AVE – SUITE 8 JACKSONVILLE, FL 32204 EVALUATION OF GROUNDWATER TABLE AT Atlantic Beach, Florida The purpose of the exploration was to collect information concerning the subsurface groundwater conditions near the proposed retention area. The evaluation was performed using a 5ft hand-auger. The hand-auger boring was performed at the location shown in the exhibit below. The initial boring was completed on Wednesday June 23, 2021 at 9am. The boring was terminated at 5’ below existing ground. 3” of water was found at the bottom of hole. The boring was checked on Thursday June 24, 2021 at 09:30am. At time of check 0” of water was found at bottom of hole. It is anticipated the Seasonal High Groundwater Elevation in the area will normally be at 4’6” below the existing ground at the boring location . Respectfully submitted, ALPHA SOUTHEAST, INC. FL C.A. 29643 Reynold D. Peterson, P.E. Sr Project Manager FL PE NO 84559 Boring Location