763 ATLANTIC BLVD COMM21-0010 MISC DWGS P's & E'sHIGH
HIGHHIGH
HIGHP2
P4
P5
EXISTING 1" COLDWATER LINEVERIFY EXACTLOCATION IN FIELD
P7P7
P912" CW TOBREAD OVEN
12" CW TOBAG IN BOX
12" CW TOBAG IN BOX
P3P1
HIGH
HIGHHIGH
HIGHP2
P4
EXISTING 4"SANITATION LINEVERIFY EXACT
LOCATION IN FIELD
NEW G.T.ZURN GB-2
P6
P7P7
P9P10
P3P1
P8
P8
P8
DD
AIR GAP = 2 X
"D" (2" MIN.)
DRAIN OUTLET
MOUNT FLUSH
WITH FINISHED
FLOOR
FLOOR DRAIN
AND STRAINER
ASSEMBLY
FUNNELASSEMBLY
EXISTING 4"
SANITATION LINE
VERIFY EXACT
LOCATION IN FIELD
P1
4"
P2
2"
2"
4"
4"
4"
3"
P10
3"
3"
4"
4"
4"
P3
2"
2"
V.T.R.
A.A.V.
P3
2"
P8TO EXISTING 4"
SANITATION LINE
VERIFY EXACTLOCATION IN FIELD
P11
P7
4"
3"P7
P8
P8
P6
P9
4"
3"
3"
2"
V.T.R.
PLUMBING
PLAN
P1
SCALE: AS NOTED
DATE:
DRAWN BY: KPL
JOB NO.:OAKWELL COMPANIES, LLC.GENERAL PLUMBING NOTES
1. ALL WORK SHALL COMPLY WITH ALL LOCAL & STATE CODES &
AUTHORITIES HAVING JURISDICTION.
2. PLUMBING CONTRACTOR SHALL SECURE & PAY FOR ALL REQUIREDPERMITS & ARRANGE ALL REQUIRED INSPECTIONS.
3. ALL CONTRACTORS SHALL EXAMINE THE SITE & REVIEW THE
DRAWINGS & SPECIFICATIONS PRIOR TO SUBMITTING A PROPOSAL.
4. CONTRACTOR SHALL VERIFY DEPTH, SIZE, LOCATION OF ALL EXISTING
UTILITIES IN FIELD PRIOR TO STARTING WORK.
5. PLUMBING CONTRACTOR SHALL COORDINATE HIS/HER WORK W/
OTHER CONTRACTORS IN ESTABLISHING PIPE RUNS & SPACECONDITIONS.
6. ALL PIPING TO BE CONCEALED IN HUNG CEILINGS, CHASES, & FURRED
SPACES.
7. THE DRAWINGS AS PREPARED ARE DIAGRAMMATIC BUT SHALL BE
FOLLOWED AS CLOSELY AS CONSTRUCTION OF THE PROJECT & THE
WORK OF THE TRADES WILL PERMIT, EQUIPMENT LOCATIONSINDICATED ARE APPROXIMATE, COORDINATE EXACT LOCATIONS &
REQUIRED CLEARANCES W/ EQUIPMENT SUPPLIER & ALL TRADES
PRIOR TO INSTALLATION.
8. REFER TO EQUIPMENT SCHEDULE & EQUIPMENT SPECS. FOR EXACT
LOCATIONS OF PLUMBING CONNECTIONS.
9. ALL KITCHEN, PREP AREA, & SALES AREA EQUIPMENT WILL BE
FURNISHED & INSTALLED. EQUIPMENT WILL BE FURNISHED W/ TRIM,FAUCETS, ESCUTCHEONS, ETC. PLUMBING CONTRACTOR SHALL
PROVIDE ALL ROUGH-IN TRAPS & MAKE ALL FINAL CONNECTIONS (SEE
EQUIPMENT SCHEDULE)
10. THIS CONTRACTOR SHALL PROVIDE & INSTALL ALL PIPE HANGERS &
SUPPORTS IN ACCORDANCE W/ THE LOCAL APPLICABLE CODES.
11. PLUMBING CONTRACTOR TO PROVIDE BACKFLOW PREVENTERS AT
ALL ICE MAKERS & ALL OTHER EQUIPMENT AS REQUIRED BY CODE.
12. PROVIDE SHELF & STRAPPING FOR WATER HEATER.
13. PROVIDE DIRECT LINE W/ TEMPERATURE REGULATOR VALVE FROM
HWH TO ALL HAND WASHING SINKS.
14. PLUMBING CONTRACTOR TO PROVIDE AERATORS ON ALL HAND SINKS
& LAVATORIES THROUGHOUT THE FACILITY.
15. PROVIDED TEMPERED WATER HAND WASHING LAVATORIES.16. ALL WASTE PIPE SHALL BE PVC TYPE GRADE PIPE. PEX PIPING TO BE
USED FOR WATER LINES.
17. PIPING TO THE INLET OF A WATER HEATER AND PIPING CONVEYING
WATER HEATED BY A WATER HEATER SHALL BE INSULATED.
18. BACKFLOW PREVENTER AND GREASE TRAP EQUIPMENT TO BE
INSPECTED BY THIRD PARTY BEFORE CO OR BUSINESS LICENSEISSUED.REV. DATE BYDESCRIPTION10950-60 SAN JOSE BLVD. #306JACKSONVILLE, FL 32223904-710-8391JIM@OAKWELLCOMPANIES.COMKATHLEEN@OAKWELLCOMPANIES.COMAUSTIN R. ACE, P.E.P.E. 354545908 Orchard Pond. Dr.Fleming Island, FL 32003P: 904-716-3661763 ATLANTIC BLVD. UNIT CATLANTIC BEACH, FL 32233763-C
2/15/21
FIXTURE NUMBERS ARE AMERICAN STANDARD, SIMILAR FIXTURES BY ELJER OR KOHLER WILL BE CONSIDERED EQUAL
TAG DESCRIPTION MANUFACTURER MODEL NO.TRIM SUPPLY WASTE VENT
P1 WATER CLOSET FLOOR
MOUNTED FLUSH AMERICAN STANDARD CADET 2292.100 WIDE ANGLE WHEEL STOP 1/2" CW 4" 2"
P2 LAVATORY WALL HUNG 8" HC AMERICAN STANDARD PENLYL 0383-027 CHICAGO FAUCET 408A-865 1/2" CW &
HW 2" 1 1/2"
P3 HAND SINK WALL HUNG CHG FS17-1014JM CHGFKL45-4000-RE4 FAUCET
1/2" CW &
HW 2" 1 1/2"
P4 HAND SINK DROP IN
1/2" CW &HW 2" 1 1/2"
P5 GAS WATER HEATER RHEEM ECO180XLN3-1 3/4" GAS LINE 3/4" CW -- --
P6 FLOOR DRAIN ZURN FD2321-P03 OR EQUAL STAINLESS STEEL COVER -- 3 2"
P7 FLOOR SINK ZURN FD2376 OR EQUAL STAINLESS STEEL COVER --3 2"
P8 FLOOR CLEANOUT ZURN CO2500 OR EQUAL BRASS COVER -- 3" 2"
P9 MOP SINK ZURN Z1996-24 STAINLESS STEEL COVER 1/2" CW &
HW 2" 1 1/2"
P10 HUB DRAIN ZURN Z1870 OR EQUAL STAINLESS STEEL COVER -- 3" 2"
P11 GREASE INTERCEPTOR ZURN GB-2 --4" 4" --
ALL PLUMBING FIXTURES & ACCESSORIES SHALL BE FURNISHED & INSTALLED IN
COMPLIANCE W/ FLORIDA ACCESSIBILITY CODE FOR BUILDINGS.
ALL PUBLIC HAND SINK TO HAVE TEMPERED WATER MEETING ASSE 1070.
Scale: 1/4"=1'
COLD/HOT WATER PLAN1 Scale: 1/4"=1'
SANITATION PLAN2
N.T.S.
CLEAN OUT DETAILA
N.T.S.
SANITATION RISER DIAGRAM4
COVER FOR
DUTY
REQUIRED
6" CONC.
VARIES
CONCRETE
SLAB
CLEANOUT ASSEMBLY
SAME SIZE AS SEWER
UP TO 8" DIA.
SEWER MATERIAL AND
SIZE AS SPECIFIED
N.T.S.
HUB DRAIN DETAILB
N.T.S.
GREASE RISER DIAGRAM3
N.T.S.
INDIRECT DRAIN DETAILC
1 1
Digitally signed by Austin R. Ace,
P.E.
DN: cn=Austin R. Ace, P.E., c=US,
o=Austin R. Ace, P.E.,
email=aace01@comcast.net
Reason: I agree to the terms defined
by the placement of my signature on
this document
Location: Atlantic Beach, FL
Date: 2021.06.15 13:53:56 -04'00'
By Toni Gindlesperger at 4:12 pm, Jul 29, 2021
HIGH
HIGHHIGH
HIGH34" MECHANICAL VALVEEMERGENCY SHUT OFFTO BE ACCESSIBLE
GAS WATER HEATER:180,000 BTU
1" GAS LINE ABOVE CEILINGEXISTING GAS METERVERIFY EXACT LOCATIONIN FIELD
GAS LOAD TABLE
NATURAL GAS
MEDIUM PRESSURE
INLET PRESSURE: 2.0 PSI
PRESSURE DROP: 1.0 PSI
STEEL (SCHEDULE 40)
APPROX. LENGTH: 66 FT
FITTING FACTOR: 1.5
EQUIVALENT LENGTH: 98 FT
GAS LOAD IN MBH
WATER HEATER 180
GRILLE 180
TOTAL 360 MBH
NOTE
NATURAL GAS PIPING IS SIZED FOR 2 PSI.
CONTRACTOR SHALL VERIFY THE
AVAILABILITY OF 2 PSI SERVICE BEFORE
ANY WORK HAS BEGUN AND NOTIFY
DESIGNER IN WRITING IF 2 PSI GAS
SERVICE IS NOT AVAILABLE.
PROVIDE GAS REGULATOR AT EACH PIECE
OF GAS-FIRED EQUIPMENT TO PROVIDE
PRESSURE TO UNIT AS REQUIRED BY
EQUIPMENT MANUFACTURER.
SCALE: AS NOTED
DRAWING NO.
DATE:
DRAWN BY: KPL
JOB NO.:OAKWELL COMPANIES, LLC.10950-60 SAN JOSE BLVD. #306JACKSONVILLE, FL 32223904-710-8391JIM@OAKWELLCOMPANIES.COMKATHLEEN@OAKWELLCOMPANIES.COMAUSTIN R. ACE, P.E.P.E. 171805908 Orchard Pond. Dr.Fleming Island, FL 32003P: 904-716-3661763 ATLANTIC BLVD. UNIT CATLANTIC BEACH, FL 32233763-C
2/15/21REV. DATE BYDESCRIPTION1 6/10/21 KPLCOOLER REPOSITIONP2
GAS PLAN
1
Digitally signed by Austin R.
Ace, P.E.
DN: cn=Austin R. Ace, P.E.,
c=US, o=Austin R. Ace, P.E.,
email=aace01@comcast.net
Reason: I agree to the terms
defined by the placement of
my signature on this
document
Location: Atlantic Beach, FL
Date: 2021.06.15 13:54:30 -
04'00'
By Toni Gindlesperger at 4:03 pm, Jul 29, 2021
HIGH
HIGHHIGH
HIGHA17
GFI 18" AFFA27JA29J
A37A6GFI 18" AFF24" AFFGFIA8
GFI 18" AFFA14J A16J
42" AFF
GFI
GFI 18" AFFCLG.CLG.B524" AFF
GFI
A39B2J
"A"
42" AFFGFI A35
42" AFF
GFI A33
18" AFFGFI A26
"B"
18" AFFGFI A12 B1242" AFFGFIB1124" AFFGFIA3218" AFFGFI NEMA 5-15B10
42" AFF
GFIB9
24" AFF
GFIA11
B7
ROOF
A24 54" AFFGFI42" AFFGFI42" AFFGFIA21,23,25J B14B6J
B1B384" AFFGFI84" AFFGFIJ J
A10A28A13,15TBD AFFA30
GFI 18" AFF
GFI 18" AFF
B15
A19ROOF 42" AFF O.C.ELECTRICAL BOX
Scale: 1/4"=1'
ELECTRICAL PLAN1
NOTES:
1. EMERGENCY LIGHTS SHALL BE CONNECTED TO LOCAL AREA
LIGHTING CIRCUIT AHEAD OF ANY SWITCHING DEVICES PER
NEC 701.12 (F). EMERGENCY LIGHTING SHALL PROVIDED A
MINIMUM OF 1 FOOT CANDLE OF ILLUMINATION FOR ALL
EGRESS WALKWAYS. ADDITIONAL FIXTURES MAY BE REQUIRED.
2. ALL 15 AMP & 20 AMP 125 VOLT RECEPTACLES REQUIRE GFCI
PROTECTION IN KITCHEN AREA.
3. ALL EQUIPMENT REQUIREMENTS MUST BE VERIFIED WITH
ACTUAL EQUIPMENT DELIVERED TO SITE. ELECTRICAL
CONTRACTOR IS RESPONSIBLE FOR ADJUSTING ELECTRICAL
REQUIREMENTS AS NEEDED.
4. ELECTRICAL CONTRACTOR TO FIELD VERIFY & TRACE EACH
CIRCUIT FOR CORRECT BREAKER LOAD & SIZE. REFER TO
SPECIFIC EQUIPMENT LABEL OR CUT SHEET AS REQUIRED TO
MEET NEC.
5. ALL EQUIPMENT CUT SHEET DESIGNATING ELECTRICAL POWER
& BREAKER REQUIREMENTS SHALL BE VERIFIED WITH THE
PANEL SCHEDULE PRIOR TO WORK. ANY DISCREPANCIES
SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGN
PROFESSIONAL.
6. ALL 10-VOLT, 15 & 20 AMPERE KITCHEN RECEPTACLES SHALL
BE PROVIDED WITH GROUND FAULT PROTECTION PER ARTICLE
210.8(B)(2) NEC INCLUDING FRONT AREA COUNTER.
7. PROVIDE GFCI PROTECTION FOR ALL 120 VOLT, 15 & 20 AMPERE
RECEPTACLES WITHIN 6' OF SINK PER ARTICLE 210.8(B)(2) NEC.
8. COOLER & FREEZER CONDENSERS SHALL NOT BE REMOTED.
LOCATED ON TOP OF COOLER/FREEZER UNITS.
9. WIRING METHOD IS EMT WITH THHNL MC CABLE. SERVICE IN
PVC.
10. CONDUCTOR PROPERTIES:
COPPER CONDUCTORS #12 - #4
ALUMINUM ON CONDUCTORS LARGER THAN #4
11. SIGN CIRCUIT TO CODE ART 600.5.
12. WITHIN 30 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE,
RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE
PROVIDED TO THE BUILDING OWNER, INCLUDING:
A. A SINGLE-LINE DIAGRAM OF THE BUILDING ELECTRICAL
DISTRIBUTION SYSTEM AND
B. FLOOR PLANS INDICATING LOCATION AND AREA SERVED FOR
ALL DISTRIBUTION
13. DOCUMENTS CERTIFYING THAT THE INSTALLED LIGHTING
CONTROLS MEET DOCUMENTED PERFORMANCE CRITERIA OF
SECTION C405 SHALL BE PROVIDED TO TO THE BUILDING
OWNER WITHIN 90 DAYS FROM THE DATE OF RECEIPT OF THE
CERTIFICATE OF OCCUPANCY.
14. LIGHT SOURCES FOR WALK IN COOLER/FREEZER UNITS SHALL
HAVE AN EFFICACY OF NOT LESS THAN 40 LUMENS PER WATT,
INCLUDING ANY BALLAST LOSSES, OR SHALL BE PROVIDED
WITH A DEVICE THAT AUTOMATICALLY TURNS OFF THE LIGHTS
WITHIN 15 MINUTES OF WHEN THE WALK IN COOLER OR WALK
IN FREEZER WAS LAST OCCUPIED.
SERVICE LOAD CALCULATIONS
VOLTAGE:120 / 208
PHASE:THREE
SQ. FT:1,265
LIGHTING 930 X 3.5 X 1.25 =4,069 VA
POWER 30 - DUPLEX RECEPTACLES 30 X 180 5,400 VA *DEMAND FACTOR N/A
KITCHEN EQUIPMENT 31,900 VA @ 65% DEMAND FACTOR 20,735 VA
REFRIGERATION &
HOOD EXHAUST 9,000 VA
HEAT 1 X 10,000 =10,000 VA
TOTAL:49,204 VA ~ (208X1.732)= 137 AMP
N.T.S.
ONE LINE DIAGRAM3
SCALE: 1/2"=1'
CNT. TOP FOOD WARMER2
120Y/208V
UTILITY
TRANSFORMER
SPD
MAIN #1
STACK 1 STACK 2
STACK 3
PANEL
'HPE'
SPD
EXISTING
EXISTING
MAIN
SERVICE DIS-
CONNECT
208Y/120V
3PH, 4W
EXISTING
TENANT DISCONNECT
208Y/120V
3PH, 4W
"A"
200A PANEL
208Y/120V
3PH, 3W
EXISTING
"B"
100A PANEL
208Y/120V
3PH, 3W
NEW
SCALE: AS NOTED
DRAWING NO.
DATE:
DRAWN BY: KPL
JOB NO.:OAKWELL COMPANIES, LLC.10950-60 SAN JOSE BLVD. #306JACKSONVILLE, FL 32223904-710-8391JIM@OAKWELLCOMPANIES.COMKATHLEEN@OAKWELLCOMPANIES.COMAUSTIN R. ACE, P.E.P.E. 171805908 Orchard Pond. Dr.Fleming Island, FL 32003P: 904-716-3661763 ATLANTIC BLVD. UNIT CATLANTIC BEACH, FL 32233763-C
2/15/21REV. DATE BYDESCRIPTION1 6/10/21 KPLCOOLER REPOSITIONE1
ELECTRICAL
PLAN
1
By Toni Gindlesperger at 4:05 pm, Jul 29, 2021
A20
S
A31
A2
HVAC SOFFIT
HVAC SOFFIT HVAC SOFFIT
HVAC SOFFITHVAC SOFFITOS
CLG.
B4
OS
CLG.
OS
8'-6"Scale: 1/4"=1'
LIGHTING PLAN1
ELECTRICAL LEGEND
SYMBOL DESCRIPTION COMMENTS
2'X4' LED LAY-IN W/ ACRYLIC LENSES KITCHEN
2'X2' LED LAY-IN W/ ACRYLIC LENSES KITCHEN
2'X2' LED LAY-IN W/ PARABOLIC LENSES CUSTOMER AREA/RESTROOMS
2'X4' LED LAY-IN W/ PARABOLIC LENSES CUSTOMER AREA/RESTROOMS
LED LINEAR LIGHT 1X4 FOR USE IN OPEN CEILING CONDITIONS. MOUNT AT 12'-0"AFF
LED TRACK LIGHTING
MOUNT AT 9'-0" AFF. TRACK LIGHTING IN FRONT OF MENU FACES HEADS TOWARDS
MENU BOARD. TRACK LIGHTING ABOVE MEAT CASE AND SLICER FACES HEADS DOWN
TOWARD EQUIPMENT BELOW.
LED WALL SCONCE MOUNT AT 8'-6" AFF
LED ACCENT PENDANT OVER COMMUNITY TABLE SEATING. REFER TO SURFBOARD DETAIL.
LUMINAIRE SCHEDULE NOTES:
1. LIGHTING FIXTURES AND LAMPS IN THE ABOVE SCHEDULE ARE PROVIDED BY THE CONTRACTOR VIA A NATIONAL CONTRACT WITH HERMITAGE LIGHTING NATIONAL ACCOUNTS. THE CONTRACTOR IS RESPONSIBLE FOR
PURCHASING AND INSTALLING THE LIGHTING FIXTURES. ANY QUESTIONS REGARDING FIXTURE AND LAMP TYPES, INSTALLATION REQUIREMENTS, AND ORDERS SHALL BE WITH WYATT CULVER OF HERMITAGE LIGHTINGAT (800) 264-3383, OR (615) 843-3379 OR LEE DANIELS AT (615) 843-3364.
LIGHTING FIXTURE (LUMINAIRE) SCHEDULE
TYPE CATALOG NUMBER NO. LAMPS/TYPE WATTS VOLTS MOUNTING DESCRIPTION
A 72010201 LED 50 120 LAY IN 2X4 FLAT PANEL LED
A1 09702235 LED 60 120 LAY IN 2X4 DIRECT/INDIRECT PARABOLIC LED
A2 72017227 LED 40 120 LAY IN 1X4 FLAT PANEL LED
B 72010243 LED 40 120 LAY IN 2X2 FLAT PANEL LED
B1 09702243 LED 42 120 LAY IN 2X2 DIRECT/INDIRECT PARABOLIC LED
T1 18644197 LED 10 120 TRACK WHITE TRACKHEAD FOR MENUBOARD AND ABOVE MEAT CASE AND SLICER
W1 86703506 LED 6 120 WALL WALL SCONCE POLISHED NICKEL. G40 LED FILAMENT BULB
P1 86703496 LED 6 120 PENDANT PENDANT POLISHED NICKEL. G40 LED FILAMENT BULB
LL 51900837 LED 40 120 SUSPENSION 4' WHITE LINEAR LIGHT
E1 90902323 LED 2.2 120 WALL 2-HEAD 6V EMERGENCY
E2 90900301 LED 3.6 120 WALL EXIT UNIV. LED RED
E3 90902167 LED 2.2 120 WALL EXIT/EMERG. COMBO LED W/REMOTE
EEM 90903462 LED 2.2 120 WALL OUTDOOR EMERGENCY EGRESS LIGHT
SCALE: 1/2"=1'
SCONCE LIGHTING DETAIL2
A
B1
W1E3
T1
B1
B1 B1 B1
B1
W1
W1
T1
A
A
AA
E3
E1
E1
B1
SCALE: AS NOTED
DRAWING NO.
DATE:
DRAWN BY: KPL
JOB NO.:OAKWELL COMPANIES, LLC.10950-60 SAN JOSE BLVD. #306JACKSONVILLE, FL 32223904-710-8391JIM@OAKWELLCOMPANIES.COMKATHLEEN@OAKWELLCOMPANIES.COMAUSTIN R. ACE, P.E.P.E. 171805908 Orchard Pond. Dr.Fleming Island, FL 32003P: 904-716-3661763 ATLANTIC BLVD. UNIT CATLANTIC BEACH, FL 32233763-C
2/15/21REV. DATE BYDESCRIPTION1 6/10/21 KPLCOOLER REPOSITIONE2
LIGHTING
PLAN
1
Digitally signed by Austin R. Ace,
P.E.
DN: cn=Austin R. Ace, P.E., c=US,
o=Austin R. Ace, P.E.,
email=aace01@comcast.net
Reason: I agree to the terms
defined by the placement of my
signature on this document
Location: Atlantic Beach, FL
Date: 2021.06.15 13:48:13 -04'00'
By Toni Gindlesperger at 4:07 pm, Jul 29, 2021