763 ATLANTIC BLVD COMM21-0010 MISC DWGS P's & E'sHIGH HIGHHIGH HIGHP2 P4 P5 EXISTING 1" COLDWATER LINEVERIFY EXACTLOCATION IN FIELD P7P7 P912" CW TOBREAD OVEN 12" CW TOBAG IN BOX 12" CW TOBAG IN BOX P3P1 HIGH HIGHHIGH HIGHP2 P4 EXISTING 4"SANITATION LINEVERIFY EXACT LOCATION IN FIELD NEW G.T.ZURN GB-2 P6 P7P7 P9P10 P3P1 P8 P8 P8 DD AIR GAP = 2 X "D" (2" MIN.) DRAIN OUTLET MOUNT FLUSH WITH FINISHED FLOOR FLOOR DRAIN AND STRAINER ASSEMBLY FUNNELASSEMBLY EXISTING 4" SANITATION LINE VERIFY EXACT LOCATION IN FIELD P1 4" P2 2" 2" 4" 4" 4" 3" P10 3" 3" 4" 4" 4" P3 2" 2" V.T.R. A.A.V. P3 2" P8TO EXISTING 4" SANITATION LINE VERIFY EXACTLOCATION IN FIELD P11 P7 4" 3"P7 P8 P8 P6 P9 4" 3" 3" 2" V.T.R. PLUMBING PLAN P1 SCALE: AS NOTED DATE: DRAWN BY: KPL JOB NO.:OAKWELL COMPANIES, LLC.GENERAL PLUMBING NOTES 1. ALL WORK SHALL COMPLY WITH ALL LOCAL & STATE CODES & AUTHORITIES HAVING JURISDICTION. 2. PLUMBING CONTRACTOR SHALL SECURE & PAY FOR ALL REQUIREDPERMITS & ARRANGE ALL REQUIRED INSPECTIONS. 3. ALL CONTRACTORS SHALL EXAMINE THE SITE & REVIEW THE DRAWINGS & SPECIFICATIONS PRIOR TO SUBMITTING A PROPOSAL. 4. CONTRACTOR SHALL VERIFY DEPTH, SIZE, LOCATION OF ALL EXISTING UTILITIES IN FIELD PRIOR TO STARTING WORK. 5. PLUMBING CONTRACTOR SHALL COORDINATE HIS/HER WORK W/ OTHER CONTRACTORS IN ESTABLISHING PIPE RUNS & SPACECONDITIONS. 6. ALL PIPING TO BE CONCEALED IN HUNG CEILINGS, CHASES, & FURRED SPACES. 7. THE DRAWINGS AS PREPARED ARE DIAGRAMMATIC BUT SHALL BE FOLLOWED AS CLOSELY AS CONSTRUCTION OF THE PROJECT & THE WORK OF THE TRADES WILL PERMIT, EQUIPMENT LOCATIONSINDICATED ARE APPROXIMATE, COORDINATE EXACT LOCATIONS & REQUIRED CLEARANCES W/ EQUIPMENT SUPPLIER & ALL TRADES PRIOR TO INSTALLATION. 8. REFER TO EQUIPMENT SCHEDULE & EQUIPMENT SPECS. FOR EXACT LOCATIONS OF PLUMBING CONNECTIONS. 9. ALL KITCHEN, PREP AREA, & SALES AREA EQUIPMENT WILL BE FURNISHED & INSTALLED. EQUIPMENT WILL BE FURNISHED W/ TRIM,FAUCETS, ESCUTCHEONS, ETC. PLUMBING CONTRACTOR SHALL PROVIDE ALL ROUGH-IN TRAPS & MAKE ALL FINAL CONNECTIONS (SEE EQUIPMENT SCHEDULE) 10. THIS CONTRACTOR SHALL PROVIDE & INSTALL ALL PIPE HANGERS & SUPPORTS IN ACCORDANCE W/ THE LOCAL APPLICABLE CODES. 11. PLUMBING CONTRACTOR TO PROVIDE BACKFLOW PREVENTERS AT ALL ICE MAKERS & ALL OTHER EQUIPMENT AS REQUIRED BY CODE. 12. PROVIDE SHELF & STRAPPING FOR WATER HEATER. 13. PROVIDE DIRECT LINE W/ TEMPERATURE REGULATOR VALVE FROM HWH TO ALL HAND WASHING SINKS. 14. PLUMBING CONTRACTOR TO PROVIDE AERATORS ON ALL HAND SINKS & LAVATORIES THROUGHOUT THE FACILITY. 15. PROVIDED TEMPERED WATER HAND WASHING LAVATORIES.16. ALL WASTE PIPE SHALL BE PVC TYPE GRADE PIPE. PEX PIPING TO BE USED FOR WATER LINES. 17. PIPING TO THE INLET OF A WATER HEATER AND PIPING CONVEYING WATER HEATED BY A WATER HEATER SHALL BE INSULATED. 18. BACKFLOW PREVENTER AND GREASE TRAP EQUIPMENT TO BE INSPECTED BY THIRD PARTY BEFORE CO OR BUSINESS LICENSEISSUED.REV. DATE BYDESCRIPTION10950-60 SAN JOSE BLVD. #306JACKSONVILLE, FL 32223904-710-8391JIM@OAKWELLCOMPANIES.COMKATHLEEN@OAKWELLCOMPANIES.COMAUSTIN R. ACE, P.E.P.E. 354545908 Orchard Pond. Dr.Fleming Island, FL 32003P: 904-716-3661763 ATLANTIC BLVD. UNIT CATLANTIC BEACH, FL 32233763-C 2/15/21 FIXTURE NUMBERS ARE AMERICAN STANDARD, SIMILAR FIXTURES BY ELJER OR KOHLER WILL BE CONSIDERED EQUAL TAG DESCRIPTION MANUFACTURER MODEL NO.TRIM SUPPLY WASTE VENT P1 WATER CLOSET FLOOR MOUNTED FLUSH AMERICAN STANDARD CADET 2292.100 WIDE ANGLE WHEEL STOP 1/2" CW 4" 2" P2 LAVATORY WALL HUNG 8" HC AMERICAN STANDARD PENLYL 0383-027 CHICAGO FAUCET 408A-865 1/2" CW & HW 2" 1 1/2" P3 HAND SINK WALL HUNG CHG FS17-1014JM CHGFKL45-4000-RE4 FAUCET 1/2" CW & HW 2" 1 1/2" P4 HAND SINK DROP IN 1/2" CW &HW 2" 1 1/2" P5 GAS WATER HEATER RHEEM ECO180XLN3-1 3/4" GAS LINE 3/4" CW -- -- P6 FLOOR DRAIN ZURN FD2321-P03 OR EQUAL STAINLESS STEEL COVER -- 3 2" P7 FLOOR SINK ZURN FD2376 OR EQUAL STAINLESS STEEL COVER --3 2" P8 FLOOR CLEANOUT ZURN CO2500 OR EQUAL BRASS COVER -- 3" 2" P9 MOP SINK ZURN Z1996-24 STAINLESS STEEL COVER 1/2" CW & HW 2" 1 1/2" P10 HUB DRAIN ZURN Z1870 OR EQUAL STAINLESS STEEL COVER -- 3" 2" P11 GREASE INTERCEPTOR ZURN GB-2 --4" 4" -- ALL PLUMBING FIXTURES & ACCESSORIES SHALL BE FURNISHED & INSTALLED IN COMPLIANCE W/ FLORIDA ACCESSIBILITY CODE FOR BUILDINGS. ALL PUBLIC HAND SINK TO HAVE TEMPERED WATER MEETING ASSE 1070. Scale: 1/4"=1' COLD/HOT WATER PLAN1 Scale: 1/4"=1' SANITATION PLAN2 N.T.S. CLEAN OUT DETAILA N.T.S. SANITATION RISER DIAGRAM4 COVER FOR DUTY REQUIRED 6" CONC. VARIES CONCRETE SLAB CLEANOUT ASSEMBLY SAME SIZE AS SEWER UP TO 8" DIA. SEWER MATERIAL AND SIZE AS SPECIFIED N.T.S. HUB DRAIN DETAILB N.T.S. GREASE RISER DIAGRAM3 N.T.S. INDIRECT DRAIN DETAILC 1 1 Digitally signed by Austin R. Ace, P.E. DN: cn=Austin R. Ace, P.E., c=US, o=Austin R. Ace, P.E., email=aace01@comcast.net Reason: I agree to the terms defined by the placement of my signature on this document Location: Atlantic Beach, FL Date: 2021.06.15 13:53:56 -04'00' By Toni Gindlesperger at 4:12 pm, Jul 29, 2021 HIGH HIGHHIGH HIGH34" MECHANICAL VALVEEMERGENCY SHUT OFFTO BE ACCESSIBLE GAS WATER HEATER:180,000 BTU 1" GAS LINE ABOVE CEILINGEXISTING GAS METERVERIFY EXACT LOCATIONIN FIELD GAS LOAD TABLE NATURAL GAS MEDIUM PRESSURE INLET PRESSURE: 2.0 PSI PRESSURE DROP: 1.0 PSI STEEL (SCHEDULE 40) APPROX. LENGTH: 66 FT FITTING FACTOR: 1.5 EQUIVALENT LENGTH: 98 FT GAS LOAD IN MBH WATER HEATER 180 GRILLE 180 TOTAL 360 MBH NOTE NATURAL GAS PIPING IS SIZED FOR 2 PSI. CONTRACTOR SHALL VERIFY THE AVAILABILITY OF 2 PSI SERVICE BEFORE ANY WORK HAS BEGUN AND NOTIFY DESIGNER IN WRITING IF 2 PSI GAS SERVICE IS NOT AVAILABLE. PROVIDE GAS REGULATOR AT EACH PIECE OF GAS-FIRED EQUIPMENT TO PROVIDE PRESSURE TO UNIT AS REQUIRED BY EQUIPMENT MANUFACTURER. SCALE: AS NOTED DRAWING NO. DATE: DRAWN BY: KPL JOB NO.:OAKWELL COMPANIES, LLC.10950-60 SAN JOSE BLVD. #306JACKSONVILLE, FL 32223904-710-8391JIM@OAKWELLCOMPANIES.COMKATHLEEN@OAKWELLCOMPANIES.COMAUSTIN R. ACE, P.E.P.E. 171805908 Orchard Pond. Dr.Fleming Island, FL 32003P: 904-716-3661763 ATLANTIC BLVD. UNIT CATLANTIC BEACH, FL 32233763-C 2/15/21REV. DATE BYDESCRIPTION1 6/10/21 KPLCOOLER REPOSITIONP2 GAS PLAN 1 Digitally signed by Austin R. Ace, P.E. DN: cn=Austin R. Ace, P.E., c=US, o=Austin R. Ace, P.E., email=aace01@comcast.net Reason: I agree to the terms defined by the placement of my signature on this document Location: Atlantic Beach, FL Date: 2021.06.15 13:54:30 - 04'00' By Toni Gindlesperger at 4:03 pm, Jul 29, 2021 HIGH HIGHHIGH HIGHA17 GFI 18" AFFA27JA29J A37A6GFI 18" AFF24" AFFGFIA8 GFI 18" AFFA14J A16J 42" AFF GFI GFI 18" AFFCLG.CLG.B524" AFF GFI A39B2J "A" 42" AFFGFI A35 42" AFF GFI A33 18" AFFGFI A26 "B" 18" AFFGFI A12 B1242" AFFGFIB1124" AFFGFIA3218" AFFGFI NEMA 5-15B10 42" AFF GFIB9 24" AFF GFIA11 B7 ROOF A24 54" AFFGFI42" AFFGFI42" AFFGFIA21,23,25J B14B6J B1B384" AFFGFI84" AFFGFIJ J A10A28A13,15TBD AFFA30 GFI 18" AFF GFI 18" AFF B15 A19ROOF 42" AFF O.C.ELECTRICAL BOX Scale: 1/4"=1' ELECTRICAL PLAN1 NOTES: 1. EMERGENCY LIGHTS SHALL BE CONNECTED TO LOCAL AREA LIGHTING CIRCUIT AHEAD OF ANY SWITCHING DEVICES PER NEC 701.12 (F). EMERGENCY LIGHTING SHALL PROVIDED A MINIMUM OF 1 FOOT CANDLE OF ILLUMINATION FOR ALL EGRESS WALKWAYS. ADDITIONAL FIXTURES MAY BE REQUIRED. 2. ALL 15 AMP & 20 AMP 125 VOLT RECEPTACLES REQUIRE GFCI PROTECTION IN KITCHEN AREA. 3. ALL EQUIPMENT REQUIREMENTS MUST BE VERIFIED WITH ACTUAL EQUIPMENT DELIVERED TO SITE. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ADJUSTING ELECTRICAL REQUIREMENTS AS NEEDED. 4. ELECTRICAL CONTRACTOR TO FIELD VERIFY & TRACE EACH CIRCUIT FOR CORRECT BREAKER LOAD & SIZE. REFER TO SPECIFIC EQUIPMENT LABEL OR CUT SHEET AS REQUIRED TO MEET NEC. 5. ALL EQUIPMENT CUT SHEET DESIGNATING ELECTRICAL POWER & BREAKER REQUIREMENTS SHALL BE VERIFIED WITH THE PANEL SCHEDULE PRIOR TO WORK. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGN PROFESSIONAL. 6. ALL 10-VOLT, 15 & 20 AMPERE KITCHEN RECEPTACLES SHALL BE PROVIDED WITH GROUND FAULT PROTECTION PER ARTICLE 210.8(B)(2) NEC INCLUDING FRONT AREA COUNTER. 7. PROVIDE GFCI PROTECTION FOR ALL 120 VOLT, 15 & 20 AMPERE RECEPTACLES WITHIN 6' OF SINK PER ARTICLE 210.8(B)(2) NEC. 8. COOLER & FREEZER CONDENSERS SHALL NOT BE REMOTED. LOCATED ON TOP OF COOLER/FREEZER UNITS. 9. WIRING METHOD IS EMT WITH THHNL MC CABLE. SERVICE IN PVC. 10. CONDUCTOR PROPERTIES: COPPER CONDUCTORS #12 - #4 ALUMINUM ON CONDUCTORS LARGER THAN #4 11. SIGN CIRCUIT TO CODE ART 600.5. 12. WITHIN 30 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER, INCLUDING: A. A SINGLE-LINE DIAGRAM OF THE BUILDING ELECTRICAL DISTRIBUTION SYSTEM AND B. FLOOR PLANS INDICATING LOCATION AND AREA SERVED FOR ALL DISTRIBUTION 13. DOCUMENTS CERTIFYING THAT THE INSTALLED LIGHTING CONTROLS MEET DOCUMENTED PERFORMANCE CRITERIA OF SECTION C405 SHALL BE PROVIDED TO TO THE BUILDING OWNER WITHIN 90 DAYS FROM THE DATE OF RECEIPT OF THE CERTIFICATE OF OCCUPANCY. 14. LIGHT SOURCES FOR WALK IN COOLER/FREEZER UNITS SHALL HAVE AN EFFICACY OF NOT LESS THAN 40 LUMENS PER WATT, INCLUDING ANY BALLAST LOSSES, OR SHALL BE PROVIDED WITH A DEVICE THAT AUTOMATICALLY TURNS OFF THE LIGHTS WITHIN 15 MINUTES OF WHEN THE WALK IN COOLER OR WALK IN FREEZER WAS LAST OCCUPIED. SERVICE LOAD CALCULATIONS VOLTAGE:120 / 208 PHASE:THREE SQ. FT:1,265 LIGHTING 930 X 3.5 X 1.25 =4,069 VA POWER 30 - DUPLEX RECEPTACLES 30 X 180 5,400 VA *DEMAND FACTOR N/A KITCHEN EQUIPMENT 31,900 VA @ 65% DEMAND FACTOR 20,735 VA REFRIGERATION & HOOD EXHAUST 9,000 VA HEAT 1 X 10,000 =10,000 VA TOTAL:49,204 VA ~ (208X1.732)= 137 AMP N.T.S. ONE LINE DIAGRAM3 SCALE: 1/2"=1' CNT. TOP FOOD WARMER2 120Y/208V UTILITY TRANSFORMER SPD MAIN #1 STACK 1 STACK 2 STACK 3 PANEL 'HPE' SPD EXISTING EXISTING MAIN SERVICE DIS- CONNECT 208Y/120V 3PH, 4W EXISTING TENANT DISCONNECT 208Y/120V 3PH, 4W "A" 200A PANEL 208Y/120V 3PH, 3W EXISTING "B" 100A PANEL 208Y/120V 3PH, 3W NEW SCALE: AS NOTED DRAWING NO. DATE: DRAWN BY: KPL JOB NO.:OAKWELL COMPANIES, LLC.10950-60 SAN JOSE BLVD. #306JACKSONVILLE, FL 32223904-710-8391JIM@OAKWELLCOMPANIES.COMKATHLEEN@OAKWELLCOMPANIES.COMAUSTIN R. ACE, P.E.P.E. 171805908 Orchard Pond. Dr.Fleming Island, FL 32003P: 904-716-3661763 ATLANTIC BLVD. UNIT CATLANTIC BEACH, FL 32233763-C 2/15/21REV. DATE BYDESCRIPTION1 6/10/21 KPLCOOLER REPOSITIONE1 ELECTRICAL PLAN 1 By Toni Gindlesperger at 4:05 pm, Jul 29, 2021 A20 S A31 A2 HVAC SOFFIT HVAC SOFFIT HVAC SOFFIT HVAC SOFFITHVAC SOFFITOS CLG. B4 OS CLG. OS 8'-6"Scale: 1/4"=1' LIGHTING PLAN1 ELECTRICAL LEGEND SYMBOL DESCRIPTION COMMENTS 2'X4' LED LAY-IN W/ ACRYLIC LENSES KITCHEN 2'X2' LED LAY-IN W/ ACRYLIC LENSES KITCHEN 2'X2' LED LAY-IN W/ PARABOLIC LENSES CUSTOMER AREA/RESTROOMS 2'X4' LED LAY-IN W/ PARABOLIC LENSES CUSTOMER AREA/RESTROOMS LED LINEAR LIGHT 1X4 FOR USE IN OPEN CEILING CONDITIONS. MOUNT AT 12'-0"AFF LED TRACK LIGHTING MOUNT AT 9'-0" AFF. TRACK LIGHTING IN FRONT OF MENU FACES HEADS TOWARDS MENU BOARD. TRACK LIGHTING ABOVE MEAT CASE AND SLICER FACES HEADS DOWN TOWARD EQUIPMENT BELOW. LED WALL SCONCE MOUNT AT 8'-6" AFF LED ACCENT PENDANT OVER COMMUNITY TABLE SEATING. REFER TO SURFBOARD DETAIL. LUMINAIRE SCHEDULE NOTES: 1. LIGHTING FIXTURES AND LAMPS IN THE ABOVE SCHEDULE ARE PROVIDED BY THE CONTRACTOR VIA A NATIONAL CONTRACT WITH HERMITAGE LIGHTING NATIONAL ACCOUNTS. THE CONTRACTOR IS RESPONSIBLE FOR PURCHASING AND INSTALLING THE LIGHTING FIXTURES. ANY QUESTIONS REGARDING FIXTURE AND LAMP TYPES, INSTALLATION REQUIREMENTS, AND ORDERS SHALL BE WITH WYATT CULVER OF HERMITAGE LIGHTINGAT (800) 264-3383, OR (615) 843-3379 OR LEE DANIELS AT (615) 843-3364. LIGHTING FIXTURE (LUMINAIRE) SCHEDULE TYPE CATALOG NUMBER NO. LAMPS/TYPE WATTS VOLTS MOUNTING DESCRIPTION A 72010201 LED 50 120 LAY IN 2X4 FLAT PANEL LED A1 09702235 LED 60 120 LAY IN 2X4 DIRECT/INDIRECT PARABOLIC LED A2 72017227 LED 40 120 LAY IN 1X4 FLAT PANEL LED B 72010243 LED 40 120 LAY IN 2X2 FLAT PANEL LED B1 09702243 LED 42 120 LAY IN 2X2 DIRECT/INDIRECT PARABOLIC LED T1 18644197 LED 10 120 TRACK WHITE TRACKHEAD FOR MENUBOARD AND ABOVE MEAT CASE AND SLICER W1 86703506 LED 6 120 WALL WALL SCONCE POLISHED NICKEL. G40 LED FILAMENT BULB P1 86703496 LED 6 120 PENDANT PENDANT POLISHED NICKEL. G40 LED FILAMENT BULB LL 51900837 LED 40 120 SUSPENSION 4' WHITE LINEAR LIGHT E1 90902323 LED 2.2 120 WALL 2-HEAD 6V EMERGENCY E2 90900301 LED 3.6 120 WALL EXIT UNIV. LED RED E3 90902167 LED 2.2 120 WALL EXIT/EMERG. COMBO LED W/REMOTE EEM 90903462 LED 2.2 120 WALL OUTDOOR EMERGENCY EGRESS LIGHT SCALE: 1/2"=1' SCONCE LIGHTING DETAIL2 A B1 W1E3 T1 B1 B1 B1 B1 B1 W1 W1 T1 A A AA E3 E1 E1 B1 SCALE: AS NOTED DRAWING NO. DATE: DRAWN BY: KPL JOB NO.:OAKWELL COMPANIES, LLC.10950-60 SAN JOSE BLVD. #306JACKSONVILLE, FL 32223904-710-8391JIM@OAKWELLCOMPANIES.COMKATHLEEN@OAKWELLCOMPANIES.COMAUSTIN R. ACE, P.E.P.E. 171805908 Orchard Pond. Dr.Fleming Island, FL 32003P: 904-716-3661763 ATLANTIC BLVD. UNIT CATLANTIC BEACH, FL 32233763-C 2/15/21REV. DATE BYDESCRIPTION1 6/10/21 KPLCOOLER REPOSITIONE2 LIGHTING PLAN 1 Digitally signed by Austin R. Ace, P.E. DN: cn=Austin R. Ace, P.E., c=US, o=Austin R. Ace, P.E., email=aace01@comcast.net Reason: I agree to the terms defined by the placement of my signature on this document Location: Atlantic Beach, FL Date: 2021.06.15 13:48:13 -04'00' By Toni Gindlesperger at 4:07 pm, Jul 29, 2021