763 ATLANTIC BLVD COMM21-0010 FIRE REVIEWMAX. TRAVEL DISTANCE 21'HIGH
HIGHHIGH
HIGHMAX. TRAVEL DISTANCE 55'
A0
COVER SHEET
MARK DEBIASE & DREW MAIDER
ADA STATEMENT
I HEREBY CERTIFY TO THE BEST OF MY
UNDERSTANDING THAT THE PLANS &
DRAWINGS FOR THIS PROJECT WERE DRAWN
IN ACCORDANCE WITH ALL FEDERAL, STATE, &
LOCAL LAWS, INCLUDING, BUT NOT LIMITED
TO, THE AMERICANS WITH DISABILITIES ACT
("ADA"), THE ADA ACCESSIBILITY GUIDELINES
& ANY STATE OR LOCAL ACCESSIBILITY
CODES, REGULATIONS, OR STANDARDS
SIGNATURE HERE DATE
SPRINKLERED: NO
WIND LOADS: 140 MPH REQUIRED
OCCUPANCY:
JERSEY MIKE'S - 930 SF - "B" OCCUPANCY
FBC 303.1.1 A BUILDING OR TENANT SPACE USED FOR
ASSEMBLY PURPOSES WITH AN OCCUPANT LOAD OF
LESS THAN 50 PERSONS SHALL BE CLASSIFIED AS A
GROUP "B" OCCUPANCY
AREAS:TOTAL BUILDING: 9,800 SQ. FT.BUILDING SEPARATION: N 60' + E 60' + S 60' + W 60' +
TYPE OF CONSTRUCTION: TYPE IIB
TABLE 503
ALLOW
HEIGHT
ALLOW
STORIES
ALLOW
AREA
FRONTAL
INCREASE
GROUP A-2 55'-0"2 9,500 SF
MIN. INT. FINISHES: TABLE 803.11 IN AN
UNSPRINKLERED BLDG.
EXITS:EXIT
ACCESS:OTHER:
BUSINESS:
STORAGE:
A
A
A
A
B
B
FIRE RESISTANCE RATING REQUIRED PER TABLE 601
REQ'D:PROVIDED: UL #:0STRUCTURAL FRAME:BEARING WALLS:INTERIOR:EXTERIOR:NONBEARING INTERIOR
WALLS:FLOOR CONSTRUCTION:ROOF CONSTRUCTION:
EXTERIOR WALLS
FIRE RESISTANCE RATING
REQ'D PER TABLE 602
X < 5 FT = 1 HR
FOR B OCCUPANCY
DISTANCE TO EXITS (TABLE 1017.2) DISTANCE TO ANY
EXIT SHALL NOT EXCEED 300 FOR AN
SPRINKLERED B OCCUPANCY
OCCUPANT LOAD PER TABLE 1004.5
EXITING:
OCCUPANT 1: 930 SF / 100 SF = 9.3 (10)
MINIMUM # OF EXITS: TABLE 1006.2.1
"B" OCCUPANCY
MAX. OCCUPANT LOAD OF SPACE = 49
MAX. COMMON PATH OF EGRESS TRAVEL DISTANCE
SPRINKLERED = 100
ONE EXIT REQUIRED
MINIMUM EXIT IN. REQ. = 36 X .2" = 7.2"
PROVIDED: 36"
ACTUAL OCCUPANT LOAD:8 SEATS + 5 EMPLOYEES = 13 MAX. OCCUPANTS
AS PER TABLE 2902.1RESTROOMS: 1 REQUIRED
1 PROVIDED
FIRE RATED CONST. REQ'S BETWEEN OCCUPANCIES:
WALL BETWEEN THIS OCCUPANCY & ALL OTHER
OCCUPANCIES HAS 2 HR. WALL
BUILDING CODE ANALYSIS
LIFE SAFETY NOTES
·ELECTRICAL SERVICE DISCONNECT SIGNAGE PER
NFPA 70 TO BE PROVIDED
·EACH SERVICE DISCONNECT SHALL BE
PERMANENTLY MARKED TO IDENTIFY IT AS A
SERVICE DISCONNECT
·PROVIDE TACTILE EXIT SIGNAGE PER NFPA 101
7.10.1
·ALL FIRE EXTINGUISHERS TYPE: KITCHEN CLASS
K
·MOUNT FIRE EXTINGUISHERS MAX 5'-0" A.F.F.
·DINING AREA TABLES & CHAIRS ARE MOVEABLE
·DUCT SMOKE DETECTORS SHALL BE PROVIDED
ON THE SUPPLY SIDE OF HVAC UNIT.
9,000 SF
2020 FLORIDA BUILDING CODE 7TH EDITION
2020 FLORIDA BUILDING CODE, ACCESSIBILITY 7TH EDITION
2020 FLORIDA BUILDING CODE, PLUMBING 7TH EDITION
2020 FLORIDA BUILDING CODE, MECHANICAL 7TH EDITION
2020 FLORIDA BUILDING CODE, FUEL GAS 7TH EDITION
2020 FLORIDA BUILDING CODE, EXIST. BUILDING 7TH EDITION
SCALE: AS NOTED
DATE:
DRAWN BY: KPL
JOB NO.:OAKWELL COMPANIES, LLC.10950-60 SAN JOSE BLVD. #306JACKSONVILLE, FL 32223904-710-8391JIM@OAKWELLCOMPANIES.COMKATHLEEN@OAKWELLCOMPANIES.COM763 ATLANTIC BLVD. UNIT CATLANTIC BEACH, FL 32233763-C
2/15/21 REV. DATE BYDESCRIPTIONScale: 1/4"=1'
LIFE SAFETY PLAN1
JERSEY MIKE'S DATA
STORE DIMENSIONS SQ. FOOTAGE AREA/OCCUPANT OCCUPANT
STANDING 46 SQ. FT,7 NET 6.4
DINING 306 SQ. FT.15 NET 20.4
KITCHEN PREP 482 SQ. FT.200 GROSS 2.4
RESTROOM 60 SQ. FT.NOT OCCUPIED
WALK IN FREEZER 36 SQ. FT.NOT OCCUPIED
TOTAL:930 SQ. FT.29.2 = 30 OCCUPANTS
SEATING
# OF TABLES 3
# OF SEATS 7
# OF BARRIER FREE
SEATING UNITS 1
STAND UP
COUNTERS (Y/N)N
TOTAL # OF SEATS 8
RESTROOMS
# OF RESTROOMS 1
PUBLIC ACCESS TO
RR Y
HANDICAP
ACCESSIBLE Y
WALK-IN COOLER/FREEZER
REMOTE COMPRESSORS REQUIRED N
DISTANCE FROM COMP. TO BOX N/A
SHEET INDEX
A-0 COVER SHEET/INDEX OF DRAWINGS
A-1 EQUIPMENT PLAN
A-2 WALL FRAMING PLAN
A-3 FLOOR PLAN
A-4 REFLECTIVE CEILING PLAN
A-5 FLOOR FINISH PLAN
A-6 WALL FINISH & GRAPHICS PLAN
A-7 INTERIOR ELEVATIONS
A-8 MILLWORK DETAILS
E-1 ELECTRICAL PLAN
E-2 LIGHTING PLAN
M-1 MECHANICAL PLAN
M-2 MECHANICAL DETAILS
M-3 HOOD DETAILS
M-4 HOOD DETAILS
M-5 HOOD DETAILS
P-1 PLUMBING PLAN
P-2 GAS PLAN
00
0
00
000
0
00
000
0
00
APPLICABLE CODES:AUSTIN R. ACE, P.E.P.E. 354545908 Orchard Pond. Dr.Fleming Island, FL 32003P: 904-716-36612017 NATIONAL ELECTRIC CODE
FLORIDA FIRE PREVENTION CODE 7TH EDITION
2020 FLORIDA BUILDING CODE, ENERGY CONS. 7TH EDITION
JERSEY MIKE'S SUB SHOP
930 SQ. FT.
"B" OCCUPANCY
N.T.S.
SITE
N.T.S.
VICINITY
PROF
ESSIONA L E N G INEERAU S T IN R. ACELICENSE
FLOR I D A
No. 35454
STATE OF
This item has been digitally signed and sealed
by Austin R. Ace, P.E. on the date adjacent to
the seal. Printed copies of this document are not
considered signed and sealed and the signature must
be verified on any electronic copies.
Digitally signed by Austin R. Ace, P.E.DN: cn=Austin R. Ace, P.E., c=US,o=Austin R. Ace, P.E.,email=aace01@comcast.netReason: I agree to the specified portionsof this documentDate: 2021.03.02 09:39:07 -05'00'
Austin R.
Ace, P.E.
By Toni Gindlesperger at 10:41 am, Mar 12, 2021
By DIPIERRI at 4:06 pm, May 03, 2021