Loading...
763 ATLANTIC BLVD COMM21-0010 FIRE REVIEWMAX. TRAVEL DISTANCE 21'HIGH HIGHHIGH HIGHMAX. TRAVEL DISTANCE 55' A0 COVER SHEET MARK DEBIASE & DREW MAIDER ADA STATEMENT I HEREBY CERTIFY TO THE BEST OF MY UNDERSTANDING THAT THE PLANS & DRAWINGS FOR THIS PROJECT WERE DRAWN IN ACCORDANCE WITH ALL FEDERAL, STATE, & LOCAL LAWS, INCLUDING, BUT NOT LIMITED TO, THE AMERICANS WITH DISABILITIES ACT ("ADA"), THE ADA ACCESSIBILITY GUIDELINES & ANY STATE OR LOCAL ACCESSIBILITY CODES, REGULATIONS, OR STANDARDS SIGNATURE HERE DATE SPRINKLERED: NO WIND LOADS: 140 MPH REQUIRED OCCUPANCY: JERSEY MIKE'S - 930 SF - "B" OCCUPANCY FBC 303.1.1 A BUILDING OR TENANT SPACE USED FOR ASSEMBLY PURPOSES WITH AN OCCUPANT LOAD OF LESS THAN 50 PERSONS SHALL BE CLASSIFIED AS A GROUP "B" OCCUPANCY AREAS:TOTAL BUILDING: 9,800 SQ. FT.BUILDING SEPARATION: N 60' + E 60' + S 60' + W 60' + TYPE OF CONSTRUCTION: TYPE IIB TABLE 503 ALLOW HEIGHT ALLOW STORIES ALLOW AREA FRONTAL INCREASE GROUP A-2 55'-0"2 9,500 SF MIN. INT. FINISHES: TABLE 803.11 IN AN UNSPRINKLERED BLDG. EXITS:EXIT ACCESS:OTHER: BUSINESS: STORAGE: A A A A B B FIRE RESISTANCE RATING REQUIRED PER TABLE 601 REQ'D:PROVIDED: UL #:0STRUCTURAL FRAME:BEARING WALLS:INTERIOR:EXTERIOR:NONBEARING INTERIOR WALLS:FLOOR CONSTRUCTION:ROOF CONSTRUCTION: EXTERIOR WALLS FIRE RESISTANCE RATING REQ'D PER TABLE 602 X < 5 FT = 1 HR FOR B OCCUPANCY DISTANCE TO EXITS (TABLE 1017.2) DISTANCE TO ANY EXIT SHALL NOT EXCEED 300 FOR AN SPRINKLERED B OCCUPANCY OCCUPANT LOAD PER TABLE 1004.5 EXITING: OCCUPANT 1: 930 SF / 100 SF = 9.3 (10) MINIMUM # OF EXITS: TABLE 1006.2.1 "B" OCCUPANCY MAX. OCCUPANT LOAD OF SPACE = 49 MAX. COMMON PATH OF EGRESS TRAVEL DISTANCE SPRINKLERED = 100 ONE EXIT REQUIRED MINIMUM EXIT IN. REQ. = 36 X .2" = 7.2" PROVIDED: 36" ACTUAL OCCUPANT LOAD:8 SEATS + 5 EMPLOYEES = 13 MAX. OCCUPANTS AS PER TABLE 2902.1RESTROOMS: 1 REQUIRED 1 PROVIDED FIRE RATED CONST. REQ'S BETWEEN OCCUPANCIES: WALL BETWEEN THIS OCCUPANCY & ALL OTHER OCCUPANCIES HAS 2 HR. WALL BUILDING CODE ANALYSIS LIFE SAFETY NOTES ·ELECTRICAL SERVICE DISCONNECT SIGNAGE PER NFPA 70 TO BE PROVIDED ·EACH SERVICE DISCONNECT SHALL BE PERMANENTLY MARKED TO IDENTIFY IT AS A SERVICE DISCONNECT ·PROVIDE TACTILE EXIT SIGNAGE PER NFPA 101 7.10.1 ·ALL FIRE EXTINGUISHERS TYPE: KITCHEN CLASS K ·MOUNT FIRE EXTINGUISHERS MAX 5'-0" A.F.F. ·DINING AREA TABLES & CHAIRS ARE MOVEABLE ·DUCT SMOKE DETECTORS SHALL BE PROVIDED ON THE SUPPLY SIDE OF HVAC UNIT. 9,000 SF 2020 FLORIDA BUILDING CODE 7TH EDITION 2020 FLORIDA BUILDING CODE, ACCESSIBILITY 7TH EDITION 2020 FLORIDA BUILDING CODE, PLUMBING 7TH EDITION 2020 FLORIDA BUILDING CODE, MECHANICAL 7TH EDITION 2020 FLORIDA BUILDING CODE, FUEL GAS 7TH EDITION 2020 FLORIDA BUILDING CODE, EXIST. BUILDING 7TH EDITION SCALE: AS NOTED DATE: DRAWN BY: KPL JOB NO.:OAKWELL COMPANIES, LLC.10950-60 SAN JOSE BLVD. #306JACKSONVILLE, FL 32223904-710-8391JIM@OAKWELLCOMPANIES.COMKATHLEEN@OAKWELLCOMPANIES.COM763 ATLANTIC BLVD. UNIT CATLANTIC BEACH, FL 32233763-C 2/15/21 REV. DATE BYDESCRIPTIONScale: 1/4"=1' LIFE SAFETY PLAN1 JERSEY MIKE'S DATA STORE DIMENSIONS SQ. FOOTAGE AREA/OCCUPANT OCCUPANT STANDING 46 SQ. FT,7 NET 6.4 DINING 306 SQ. FT.15 NET 20.4 KITCHEN PREP 482 SQ. FT.200 GROSS 2.4 RESTROOM 60 SQ. FT.NOT OCCUPIED WALK IN FREEZER 36 SQ. FT.NOT OCCUPIED TOTAL:930 SQ. FT.29.2 = 30 OCCUPANTS SEATING # OF TABLES 3 # OF SEATS 7 # OF BARRIER FREE SEATING UNITS 1 STAND UP COUNTERS (Y/N)N TOTAL # OF SEATS 8 RESTROOMS # OF RESTROOMS 1 PUBLIC ACCESS TO RR Y HANDICAP ACCESSIBLE Y WALK-IN COOLER/FREEZER REMOTE COMPRESSORS REQUIRED N DISTANCE FROM COMP. TO BOX N/A SHEET INDEX A-0 COVER SHEET/INDEX OF DRAWINGS A-1 EQUIPMENT PLAN A-2 WALL FRAMING PLAN A-3 FLOOR PLAN A-4 REFLECTIVE CEILING PLAN A-5 FLOOR FINISH PLAN A-6 WALL FINISH & GRAPHICS PLAN A-7 INTERIOR ELEVATIONS A-8 MILLWORK DETAILS E-1 ELECTRICAL PLAN E-2 LIGHTING PLAN M-1 MECHANICAL PLAN M-2 MECHANICAL DETAILS M-3 HOOD DETAILS M-4 HOOD DETAILS M-5 HOOD DETAILS P-1 PLUMBING PLAN P-2 GAS PLAN 00 0 00 000 0 00 000 0 00 APPLICABLE CODES:AUSTIN R. ACE, P.E.P.E. 354545908 Orchard Pond. Dr.Fleming Island, FL 32003P: 904-716-36612017 NATIONAL ELECTRIC CODE FLORIDA FIRE PREVENTION CODE 7TH EDITION 2020 FLORIDA BUILDING CODE, ENERGY CONS. 7TH EDITION JERSEY MIKE'S SUB SHOP 930 SQ. FT. "B" OCCUPANCY N.T.S. SITE N.T.S. VICINITY PROF ESSIONA L E N G INEERAU S T IN R. ACELICENSE FLOR I D A No. 35454 STATE OF This item has been digitally signed and sealed by Austin R. Ace, P.E. on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Digitally signed by Austin R. Ace, P.E.DN: cn=Austin R. Ace, P.E., c=US,o=Austin R. Ace, P.E.,email=aace01@comcast.netReason: I agree to the specified portionsof this documentDate: 2021.03.02 09:39:07 -05'00' Austin R. Ace, P.E. By Toni Gindlesperger at 10:41 am, Mar 12, 2021 By DIPIERRI at 4:06 pm, May 03, 2021