Loading...
2446 Seminole Rd RESO21-0022 Revision Revision Request/Correction to Comments **ALL INFORMATION HIGHLIGHTED IN GRAY IS REQUIRED. City of Atlantic Beach Building Department 800 Seminole Rd, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT #: _____________________ Revision to Issued Permit OR Corrections to Comments Date: ________________ Project Address: ____________________________________________________________________________________ Contractor/Contact Name: ____________________________________________________________________________ Contact Phone: ______________________________ Email: _________________________________________________ Description of Proposed Revision / Corrections: __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ I_______________________________ affirm the revision/correction to comments is inclusive of the proposed changes. (printed name)  Will proposed revision/corrections add additional square footage to original submittal? No Yes (additional s.f. to be added: _____________________________)  Will proposed revision/corrections add additional increase in building value to original submittal? No *Yes (additional increase in building value: $____________________) (Contractor must sign if increase in valuation) *Signature of Contractor/Agent: _______________________________________________________ __________________________________________________________________________________________________ (Office Use Only) Approved Denied Not Applicable to Department Permit Fee Due $_______________ Revision/Plan Review Comments_______________________________________________________________________ __________________________________________________________________________________________________ Department Review Required: Building _____________________________________________ Planning & Zoning Reviewed By Tree Administrator Public Works Public Utilities _____________________________________________ Public Safety Date Fire Services Updated 10/17/18 This item has been electronically signed and sealed by Harold W Coffield,PE on using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Harold W Coffield, PE 2743 Anniston Rd Jacksonville, FL 32246 904-571-7106 FL PE #50407 2020 Florida Building Code, Category 1 Top View Right ViewLeft View Front View 46' 0" 10' 6"25' 0"10' 6" 46' 0" 7' 0"7' 0"8' 0"8' 0"8' 0"8' 0" 3' 0"10' 0" 13' 6" 16' 0" 3' 0"10' 0" 13' 6" 16' 0" 13 ' 6 " 16 ' 0 " 38 ' 6 " 3' 0" 39 ' 6 " 38 ' 6 " 7' 1 1 " 7' 1 1 " 7' 1 1 " 7' 1 1 " 6' 1 1 " 9' 8 " 39 ' 6 " 7' 1 1 " 7' 1 1 " 7' 1 1 " 7' 1 1 " 7' 1 1 " Hedberg Residence 2446 Seminole Road Atlantic Beach, FL 32233 Builder: Impact Enclosures Exposure: C Wind Zone: 120 mph Existing Footer 2x5 TYP2x5 TYP 1x 2 T Y P 2x 2 T Y P 2x 2 T Y P 2x 3 T Y P 1x2 3x33x3 3x 3 3x 31/8" S.S. Cable TYP3x 3 T Y P 2x10 TYP 1x2 TYP 2x5 TYP 1 x 2 T Y P 2 x 2 T Y P 2 x 2 T Y P 2 x 3 T Y P 1x2 1x2 1x2 2x3 1 x 2 2 x 2 2 x 2 1 x 2 2x2 Purlins TYP2x32x32x 3 2x 3 2x 9 T Y P DocuSign Envelope ID: 783E77E4-0905-423C-934E-503940E9212A 8/5/2021 Harold W Coffield, PE 2743 Anniston Rd Jacksonville, FL 32246 904-571-7106 FL PE #50407 CONTINUOUS CANT BEAD OF COMPATIBLE SEALANTEXIST I N G RAFTE ROR TR U S S 2X2X1/5’’ CONTINOUS ANGLE TOP AND BOTTOM #10x3/4’ SMS @ 6” O.C. TOP AND BOTTOM 1/4” LAG BOLT TOP AND BOTTOM THROUGH RECEIVING CHANNEL @12” O.C. ROOF PANEL ATTACHMENT - WOOD FRAME1 2 2” NOMINAL STRUCTURAL FASCIA MIN. CONTINUOUS CANT BEAD OF COMPATIBLE SEALANT #10X3/4” SMS @ 12” O.C. TOP ROOF PANEL ATTACHMENT - WOOD FRAME 3 ROOF PANEL JOINT SEAL JOINT W/ COMPATIBLE SEALANT 4 1/4” LAG BOLTS @ 12” O.C. W/ 1 1/2” MIN. WASHER DIAMETER, 1” MIN. LONGER THAN PANEL THICKNESS. POST TOP PLATE FASTEN MIN. 2”X2”X1/8” ALUMINUM ANGLE W/ (3)#10x1 SMS TO TOP PLATE ON EACH SIDE OF POST. CARRIER BEAM & SUPER GUTTER CONNECTION DETAIL SHEET 1 5 6 GUTTER & SMB ATTACHMENT (2X8 & LARGER) PURLIN ATTACHMENT (2X8 & LARGER) BEAM IS ATTACHED TO GUTTER W/ 2X2X1/8TH RECEIVING CHANNEL W/ (5)#14 X 3/4 INTO GUTTER & INTO BEAM WITH 1 LESS THAN BEAM SIZE PER SIDE SMB 2” GUTTER STRAP IS ATTACHED TO GUTTER W/ (3) #10 X 2” EACH SIDE (1)#10 X 2” SMS SCREW @ 24” O.C. ENTIRE LENGTH OF GUTTER MIN. 2X6 NOM. STRUCTURAL FACIA BEAM PURLIN PURLIN IS ATTACHED TO GUTTER / FASCIA & BEAM W/ 1”X2” INTERNAL CLIP OR EXTERNAL C-CHANNEL 2” GUTTER STRAP IS ATTACHED TO GUTTER W/ (3) #10 X 2” EACH SIDE MIN. 2X6 NOM. STRUCTURAL FACIA 2” NOMINAL STRUCTURAL FASCIA MIN 1/4”X3 LAG BOLT THROUGH RECEIVING CHANNEL @ 12” O.C. 3” RECEIVING CHANNEL (1)#10 X 2” SMS SCREW @ 24” O.C. ENTIRE LENGTH OF GUTTER EXIS T I N G R A F T E R OR T R U S S 2020 Florida Building Code, Category 1 DocuSign Envelope ID: 783E77E4-0905-423C-934E-503940E9212A Harold W Coffield, PE 2743 Anniston Rd Jacksonville, FL 32246 904-571-7106 FL PE #50407 TYPICAL INTERNAL/EXTERNAL GUSSET (2X8 & LARGER)GUTTER & SMB ATTACHMENT (2X7 SMB & SMALLER) PURLIN ATTACHMENT (2X7 SMB & SMALLER) DETAIL SHEET 2 TYPICAL INTERNAL/EXTERNAL GUSSET (2X7 SMB & SMALLER) PURLIN DETAIL OPTIONS 7 12” LONG X 3/18” THICK ALUMINUM INTERNAL OR EXTERNAL GUSSET EACH SIDE. WIDTH TO MATCH BEAM PURLINS ATTACHED TO BEAM W/ (4) #10 X 3/4” SELF TAPPING SCREWS (16) #14 X 3/4” SMS EACH LEG OF GUSSET (32 SMS TOTAL) #14 X 3/4” SELF MATTING SCREWS @ 6” FROM ENDS. 24” O.C. 8 BEAM IS ATTACHED TO GUTTER W/ 2X2X1/8” RECEIVING CHANNEL WITH (5) #10X1” INTO GUTTER & INTO BEAM WITH 1 LESS THAN BEAM SIZE PER SIDE 2” GUTTER STRAP IS ATTACHED TO GUTTER W/ (3) #10 X 2” EACH SIDE (1) #10 X 2” SMS SCREW @ 24” O.C. ENTIRE LENGTH OF GUTTER MIN. 2X6 NOM. STRUCTURAL FACIA 9 10 PURLIN DETAIL OPTIONS1112 PURLINS ATTACHED TO BEAM W/ (4) #10 X 1” SELF TAPPING SCREWS. (10) #10X1” SMS EACH LEG OF GUSSET (20 SMS TOTAL) #10 X 1-1/4” SELF MATING SCREWS @ 6” FROM ENDS. 24”” O.C. 12” LONG X 3/16” THICK ALUMINUM INTERNAL OR EXTERNAL GUSSET EACH SIDE. WIDTH TO MATCH BEAM BEAM PURLIN PURLIN IS ATTACHED TO GUTTER/FASCIA & BEAM W/ 1”X2” INTERNAL CLIP OR EXTERNAL C-CHANNEL 2” GUTTER STRAP IS ATTACHED TO GUTTER W/ (3) #10X2” EACH SIDE (1) #10X2” SMS SCREW @ 24” O.C. ENTIRE LENGTH OF GUTTER MIN. 2X6 NOM. STRUCTURAL FACIA BEAM PURLIN TOP PLATE 2X2X1/8 ANGLE ATTACHED TO COLUMN & BEAM W/ (3) #10X1” PER SIDE. COLUMN PURLIN IS ATTACHED TO TOP PLATE / BEAM W/ 1”X2” INTERNAL CLIP OR EXTERNAL C-CHANNEL FASTEN W/ (4) #10X3/4” PURLIN IS ATTACHED TO TOP PLATE / BEAM W/ 1”X2” INTERNAL CLIP OR EXTERNAL C-CHANNEL FASTEN W/ (4) #10X3/4” (3) #10X3/4” FROM U-CHANNEL TO TOP PLATE PURLIN BEAM (3) #10X3/4” ATTACHES U-CHANNEL TO POST ON EACH SIDE COLUMN 2020 Florida Building Code, Category 1 DocuSign Envelope ID: 783E77E4-0905-423C-934E-503940E9212A Harold W Coffield, PE 2743 Anniston Rd Jacksonville, FL 32246 904-571-7106 FL PE #50407 SMB COLUMN CONNECTION OPTIONS SMB COLUMN CONNECTION OPTIONS CABLE CONNECTIONS AT CORNER PURLIN CHAIR & RAIL CONNECTION OPTIONS DETAIL SHEET 3 19 BOTTOM PLATE & COLUMN ATTACHMENT 13 14 SELF MATING BEAM TOP PLATE U-CHANNEL ATTACHED TO COLUMN W/ (3) #10X1” PER SIDE AND (3) #10X1” INTO TOP PLATE COLUMN #10X3/4” INTO COLUMN & BEAM W/ (1) LESS THAN BEAM SIZE PER SIDE #10X3/4” INTO COLUMN & BEAM W/ (1) LESS THAN BEAM SIZE PER SIDE SELF MATING BEAM(4) #10X2” SCREWED THROUGH BEAM, POST, & TOP PLATE COLUMN (9) #10X3/4” SMS 7”X7” X 1/8” MIN ANGLE BRACKET ON 45° ANGLE 5/16” EYE BOLT WELDED CLOSED WITH DOUBLE NUTS & DOUBLE COMPRESSION SLEEVE. COLUMN 15 PURLIN CHAIR & RAIL CONNECTION OPTIONS PURLIN & CHAIR RAIL IS ATTACHED TO BEAM W/ INTERNAL CLIP W/ (1) #10X3/4” TOP & BOTTOM & W/ (2) #10x3/4” TO BEAM PURLIN & CHAIR RAIL IS ATTACHED TO BEAM W/ INTERNAL CLIP W/ (1) #10X3/4” TOP & BOTTOM & W/ (2) #10x3/4” TO BEAM 16 17 18 SELF MATING UPRIGHT COULMN 2” MIN FOUNDATION SCREWD THROUGH ANGLE TO COLUMN W/ (3) #10X1” SELF MATING SCREW ON EACH SIDE. 1X2 BOTTOM PLATE FASTEN MIN. 2”X2”X1/8” ALUMINUM ANGLE TO SLAB W/ (2) 1/4” TAPCONS ON EACH SIDE OF COLUMN. (MIN. TAPCON EMBEDMENT INTO SLAB -2”) 1X2 BOTTOM PLATE FOUNDATION COLUMN 2020 Florida Building Code, Category 1 DocuSign Envelope ID: 783E77E4-0905-423C-934E-503940E9212A Harold W Coffield, PE 2743 Anniston Rd Jacksonville, FL 32246 904-571-7106 FL PE #50407 S.S. CABLE ATTACHMENT RISER / KNEE WALL CONNECTION DETAIL SHEET 4 20 23 3” A.S.T.M. A-36 STEEL CLIP W/ (2)2”X1/4” TAPCONS 1/8” S.S. CABLE W/ DOUBLE NUTS & DOUBLE COMPRESSION SLEEVES 45° DEGREE ANGLE 2”X2” HEAVY WALL ANGLE ATTACHED TO GUTTER W/ (4) #10X3/4 “ SCREWS ON EACH SIDE OF COLUMN GUTTER STRAP ATTACHED TO GUTTER W/ (2) #10X2” INTO BACK OF GUTTER THRU FASICA & W/ (2) #10X3/4” INTO FRONT OF GUTTER COLUMN ATTACHED TO HEAVY ANGLE W/ (1) LESS #10X3/4” THAN SIZE OF COLUMN ON EACH SIDE BOTTOM PLATE & COLUMN ATTACHMENT AT PAVERS21 22 S.S. CABLE ATTACHMENT AT PAVERS 1X2 BOTTOM PLATE FASTENED TO FOUNDATION W/ 1/4” TAPCONS 24” O.C. (MIN. TAPCON EMBEDMENT INTO FOUNDATION -2”) 2” MIN COLUMN SCREWD THROUGH ANGLE TO COLUMN W/ (3) #10X1” SELF MATING SCREW ON EACH SIDE. 1X2 BOTTOM PLATE PAVERS ON CONCRETE FOOTING FASTEN MIN. 2”X2”X1/8” ALUMINUM ANGLE TO SLAB W/ (2) 1/4” TAPCONS ON EACH SIDE OF COLUMN. (MIN. TAPCON EMBEDMENT INTO SLAB -2”) 45° DEGREE ANGLE 1/8” S.S. CABLE W/ DOUBLE NUTS & DOUBLE COMPRESSION SLEEVES 1X2 BOTTOM PLATE FASTENED TO FOUNDATION W/ 1/4” TAPCONS 24” O.C. (MIN. TAPCON EMBEDMENT INTO FOUNDATION -2”) 3” A.S.T.M. A-36 STEEL CLIP W/ (2)2”X1/4” TAPCONS PAVERS ON CONCRETE FOOTING FOUNDATION 1” PLATE 2’ 3/8” PAVER 2” EMBEDED 2020 Florida Building Code, Category 1 DocuSign Envelope ID: 783E77E4-0905-423C-934E-503940E9212A 1 2 EXPANDED VIEW DETAIL SHEET 1 U-CHANNEL DETAIL OPTION 5” 8” 10 ” 1 1/ 2 ” 1 1/ 2 ” 1 1/ 2 ” 1 1/ 2 ” (5) #14 X 3/4 TEK SCREW THROUGH 1/8" U-CHANNEL AND BEAM EACH SIDE (5) #14 X 3/4 TEK SCREW THROUGH 1/8" U-CHANNEL AND POST INTERNAL POST PER PLAN 1 1/ 2 ” 1 1/ 2 ” 1 1/ 2 ” 1 1/ 2 ” 1 7/ 1 6 ” 1 7/ 1 6 ” 1 7/ 1 6 ” 1 7/ 1 6 ” 1 7/ 1 6 ” POST PER PLAN POST PER PLAN NOTES: 1: 3X3 POST PROVIDE MINIMUM. 2” FROM EDGE OF SLAB AND PROVIDE MINIMUM 2” SPACING TO ANY OTHER CONNECTOR. SEE MFG. NOTES FOR INSTALLATION REQUIREMENTS. THREADED ROD REQUIRES 3” MINIMUM EDGE DISTANCE. 2. 4X4 POST PROVIDE MINIMUM 3 3/4 “ FROM EDGE OF SLAB AND PROVIDE MINIMUM 3 3/4” SPACING TO ANY OTHER CONNECTOR. 3. WHERE PAVERS ARE PRESENT ANCHOR LENGTH SHALL BE INCREASED BY THICKNESS OF PAVER NOT TO EXCEED 2-1/2” FOR PAVER THICKNESS MORE THANK 21/2” SPECIFICATIONS SHALL BE REQUIRED. PAVERS SHALL BE BONDED TO UNDERLYING CONCRETE FOUNDATION 4. WHERE RETURN WINDOW BEAM MEETS MASONRY WALL USE U-CHANNEL W/ (3) 2-1/4” TAPCONS INTO WALL AND (5) #12 X 3/4” INTO BEAM E/S COLLAR DETAIL OPTION 8 3/8” REF 2 1 / 6 ” HO L D 2”2” 2 1 / 6 ” HO L D .0 9 0 ” T Y P 4 1 / 8 ” HO L D 4 1/8” HOLD 6 3/8” 2 1 / 6 ” HO L D .0 9 0 ” T Y P 2 1/6” HOLD 2” 6 3 / 8 ” 4 1 / 8 ” HO L D 4 1/8” HOLD 2 1 / 6 ” HO L D 6 3/8” 4 3 / 8 ” 2 1/6” HOLD COLLAR SPACE CARRIER BEAM (6) #14 X 3/4 TEK SCREW THROUGH COLLAR AND BEAM EACH SIDE 4 X 4 X .125 POST CARRIER BEAM (6) #14 X 3/4 TEK SCREW THROUGH COLLAR AND BEAM EACH SIDE (2) ROWS (6) #14 X 3/4 TEK SCREW THROUGH COLLAR AND BEAM EACH SIDE (5) #14 X 3/4 TEK SCREW THROUGH 1/8" U-CHANNEL AND BEAM EACH SIDE (5) #14 X 3/4 TEK SCREW THROUGH 1/8" U-CHANNEL AND POST INTERNAL (6) #14 X 3/4 TEK SCREW THROUGH 1/8" U-CHANNEL AND BEAM EACH SIDE (6) #14 X 3/4 TEK SCREW THROUGH 1/8" U-CHANNEL AND POST INTERNAL 2020 Florida Building Code, Category 1 DocuSign Envelope ID: 783E77E4-0905-423C-934E-503940E9212A EXPANDED VIEW DETAIL SHEET 2 3x3 POST OR 4X4 POST ATTACHMENT OPTION3 3x3 POST OR 4X4 POST ATTACHMENT OPTION4 POST TO CARRY BEAM CONNECTION OPTION5 POST TO CARRY BEAM CONNECTION OPTION6 POST IS NOTCHED AROUND BEAM AND ATTACHES W/ (2) 3/8”X3-1/2” BOLTS PO S T BEAM BEAM 2X2X 1/8” ANGLE W/ (3) #10X1” PER SIDE NOTCHED POST ATTACHES TO CARRY BEAM W/ (8)#10X2” SMS POST FOUNDATION (3) 2”X3”X3”X1/8” ANGLES W/ (4) #14X3/4” SMS INTO POST & (1)-1/4” TAPCONS INTO FOUNDATION EACH ANGLE. OR (3) 2”X4”X4”X1/8” ANGLES W/ (4) #14X3/4” SMS INTO POST & (1)-1/4” TAPCONS INTO FOUNDATION EACH ANGLE. POST FOUNDATION (1) 2-1/2”X2-1/2”X1/8” INTERNAL POST FOOT W/ (4) 1/4” TAPCONS INTO FOUNDATION & (2) 3/8”X3-1/2” BOLTS THROUGH POST & POST FOOT. OR (1) 3-1/2”x3-1/2”x1/8” INTERNAL POST FOOT W/ (4) 1/4” TAPCONS INTO FOUNDATION & (2) 3/8”X4-1/2” BOLTS THROUGH POST &POST FOOT. 2020 Florida Building Code, Category 1 DocuSign Envelope ID: 783E77E4-0905-423C-934E-503940E9212A Harold W Coffield, PE 2743 Anniston Rd Jacksonville, FL 32246 904-571-7106 FL PE #50407 EXISTING CONCRETE DETAIL SHEET 11EXISTING PAVERS W/ 12”X12” FOOTER 2 EXISTING 4” CONCRETE EXISTING CONCRETE 4” THICK 3000 PSI EX I S T I N G C O N C R E T E 4 ” TH I C K 30 0 0 P S I EX I S T I N G P A V E R S 12 ” X 1 2 ” F O O T E R WI T H 1 # 5 T H R U O U T PAV E R S EXISTING PAVERS 12”X12” FOOTER WITH 1 #5 THRU OUT 2020 Florida Building Code, Category 1 DocuSign Envelope ID: 783E77E4-0905-423C-934E-503940E9212A DESCRIPTION ACCOUNT QTY PAID PermitTRAK $50.00 RESO21-0022 Address: 2446 SEMINOLE RD APN: 168354 0100 $50.00 BLDG SUBSEQUENT PLAN REVIEW FEES $50.00 BLDG 2ND PLAN REVIEW FEE 455-0000-322-1006 0 $50.00 TOTAL FEES PAID BY RECEIPT: R16625 $50.00 Printed: Friday, August 13, 2021 9:55 AM Date Paid: Friday, August 13, 2021 Paid By: IMPACT ENCLOSURES INC Pay Method: CREDIT CARD 496825844 1 of 1 Cashier: CG Cash Register Receipt City of Atlantic Beach Receipt Number R16625