Loading...
759 SAILFISH DR RESO20-0036 Allura_EvaluationReport rev. 8-5-21_1 NEMO|etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY EVALUATION REPORT PLYCEM USA LLC Fiber Cement Products 15055 Woodham Drive Houston, TX 77073 (281) 813-1260 Evaluation Report 9915.06.16-R4 FL20742-R4 Date of Issuance: 06/17/2016 Revision 4: 02/21/2019 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Allura™ Fiber Cement Siding LABELING: Labeling shall be in accordance with FBC 1404.10 and the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO|etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words “NEMO|etc. Evaluated” may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 3, plus an 8-page Appendix. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 02/21/2019. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing produ cts for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO|etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. NEMO|etc. NEMO ETC, LLC Evaluation Report 9915.06.16-R4 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL20742-R4 Plycem USA LLC Revision 4: 02/21/2019 Page 2 of 3 PANEL WALLS - SIDING EVALUATION: 1. SCOPE: Product Category: Panel Walls Sub-Category: Siding Compliance Statement: Allura™ Fiber Cement Siding, as produced by PLYCEM USA LLC, has demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1404.10 Physical Properties ASTM C1186 2012 1609.1 Wind ASTM E330 2002 3. REFERENCES: Entity Examination Reference Date ERD (TST6049) Transverse Load (Wind) Florida Windload Testing 06/15/2016 ERD (TST6049) Transverse Load (Wind) 7.25B/W/16 08/22/2016 ERD (TST6049) Transverse Load (Wind) The Cove 10/26/2016 ERD (TST6049) Transverse Load (Wind) 7.25/B/CMU/16 12/04/2017 HETI (TST1691) Transverse Load (Wind) HETI-01-1000 04/11/2002 HETI (TST1691) Transverse Load (Wind) HETI-01-1021 04/11/2002 HETI (TST1691) Transverse Load (Wind) HETI-01-1023 04/11/2002 HETI (TST1691) Transverse Load (Wind) HETI-01-1058 04/11/2002 HETI (TST1691) Transverse Load (Wind) HETI-01-1060 04/11/2002 ITS (TST1509) Physical Properties 3155389COQ-004 11/24/2008 ICC-ES (EVL2396) 2012 IBC/IRC Compliance ESR-1381 10/01/2016 NEMO (TST6049) Physical Properties ERD-SC13565.10.18 10/18/2018 QAI (TST9808) Transverse Load (Wind) RJ0893-5 12/20/2010 QAI (TST9808) Transverse Load (Wind) RJ0893-6 12/20/2010 QAI (TST9808) Transverse Load (Wind) RJ0893-9 12/20/2010 QAI (TST9808) Transverse Load (Wind) RJ0893-10 12/20/2010 QAI (TST9808) Transverse Load (Wind) RJ0893-11 12/20/2010 QAI (TST9808) Transverse Load (Wind) RJ0893-12 12/20/2010 QAI (TST9808) Transverse Load (Wind) RJ2420-P 04/18/2013 QAI (TST9808) Racking / Shear Load (E72) RJ6701P-5 02/09/2019 QAI (TST9808) Racking / Shear Load (E72) RJ6701P-6 02/09/2019 QAI (TST9808) Racking / Shear Load (E72) RJ6701P-1-R1 02/11/2019 QAI (TST9808) Racking / Shear Load (E72) RJ6701P-2-R1 02/11/2019 QAI (TST9808) Racking / Shear Load (E72) RJ6701P-3-R1 02/11/2019 QAI (TST9808) Racking / Shear Load (E72) RJ6701P-4-R1 02/11/2019 PLYCEM USA LLC Quality Assurance Declaration Letter 02/01/2017 QAI (QUA7628) Quality Assurance Inspection Report (NC) 07/09/2018 QAI (QUA7628) Quality Assurance Inspection Report (MX) 09/14/2018 4. PRODUCT DESCRIPTION: 4.1 Allura™ Fiber Cement Siding is composed of portland cement, silica, cellulose fiber, clay or fly ash and limestone. Allura™ Fiber Cement Siding is minimum 5/16-inch thick and meets ASTM C1186, Type A, Grade II (Reference: FBC 1404.10). 4.1.1 Vertical Panel Siding is flat, fiber-cement, panel-siding available with smooth or textured exterior surfaces; 48-inch wide by 8, 9, 10 or 12 ft long. 4.1.2 Lap Siding are flat, fiber-cement, lap-siding available with smooth or textured exterior surfaces; 5¼, 6¼, 7¼, 8¼ or 9¼-inch wide by 12 ft long. NEMO|etc. NEMO ETC, LLC Evaluation Report 9915.06.16-R4 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL20742-R4 Plycem USA LLC Revision 4: 02/21/2019 Page 3 of 3 4.1.3 Shapes Siding are flat, fiber-cement, panel-siding available with smooth or textured exterior surfaces of various designs; “Random Square Strait Edge”, “Random Square Staggered Edge”, “Half-Rounds” and “Octagons”; 16-inch wide by 48-inch. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 This Evaluation Report does not address fire-resistance-rating performance of the completed wall assemblies. 5.4 Shear load performance data for Vertical Panel Siding is presented in Appendix 2. Lap Siding and Shapes Siding are not intended for racking or shear resistance; walls shall be braced by other means as required by the Authority Having Jurisdiction. 5.5 Limitations relating to wind load resistance are outlined in Appendix 1. 5.5.1 “MDP” = Maximum Allowable Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. 5.5.2 Maximum Ultimate Wind Speeds shall be as defined in 1609.3(1), 1609.3(2) or 1609.3(3) of the 6th Edition (2017) Florida Building Code, depending on the project Risk Category (FBC 1604.5) and Exposure Category (FBC 1609.4.3), as defined by the Designer of Record and acceptable to the Authority Having Jurisdiction. Maximum Ultimate Wind Speeds are limited to projects meeting the following: ✓ Maximum height of 30 ft ✓ Enclosed building (Internal Pressure Coefficient, GCpi = + 0.18); ✓ Site conditions and location of the structure do not meet all conditions specified in Section 26.8.1 of ASCE 7-10 (Kzt = 1.0). Analysis for buildings falling outside these constraints shall be on a project-by-project basis by a Florida Registered PE. 5.6 All products in the wall assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. 6. INSTALLATION: 6.1 Allura™ Fiber Cement Siding shall be installed in accordance with PLYCEM USA LLC published installation instructions, subject to the Limitations / Conditions of Use noted herein. 6.2 The underlying wall substrate shall include a water-resistive barrier in accordance with FBC 1403.2. 6.3 Minimum system attachment requirements are set forth in Appendix 1, and shall not be exceeded. Fastener lengths noted are minimum lengths, and shall be adjusted as necessary for minimum 1-inch embedment into wood studs or minimum three full threads for metal framing (Reference: FBC 1405.16). 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Nuevo Laredo, Mexico North Wilkesboro, NC (aka, “Roaring River”) 9. QUALITY ASSURANCE ENTITY: QAI Laboratories – QUA7628; (604) 527-8378; mlansdowne@qai.org - THE EIGHT (8) PAGE APPENDICES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT - NEMO|etc. NEMO ETC, LLC Evaluation Report 9915.06.16-R4 for FL20742-R4 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 4: 02/21/2019 Prepared by: Robert Nieminen, PE-59166 Plycem USA LLC; (281) 813-1260 Appendix 1, Page 1 of 6 APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND RESISTANCE Table Type Application Fastener Engage Page 1 Allura™ Panel Siding Face Fastened Framing 2 2A Allura™ Lap Siding Blind Fastened Framing 3 2B Allura™ Lap Siding Face Fastened Framing 3 2C Allura™ Lap Siding Blind Fastened Sheathing 4 2D Allura™ Lap Siding Blind Fastened Framing & Furring Strips 5 2E Allura™ Lap Siding Blind Fastened Vertical Battens 5 3 Allura™ Shapes Siding Blind Fastened Framing 6 The following notes apply to the systems outlined herein: 1. Substrates shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 2. Fasteners shall be corrosion resistant. Fastener lengths noted are minimum lengths, and shall be adjusted as necessary for minimum 1-inch embedment into wood studs or minimum three full threads for metal framing (Reference: FBC 1405.16). 3. Vertical joints shall occur over wall framing and shall be staggered on subsequent courses. The siding shall be applied with a minimum 1¼ inch overlap. Position the fasteners ¾ inch from the top edge of the siding. Fasten 3/8 inch from butt ends. For installation over metal wall studs, a minimum of ½ inch thick gypsum shall be applied on the interior surface. 4. “MDP” = Maximum Allowable Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. 5. Maximum Ultimate Wind Speeds shall be as defined in Figures 1609.3(1), 1609.3(2) or 1609.3(3) of the 6th Edition (2017) Florida Building Code, depending on the project Risk Category (FBC 1604.5) and Exposure Category (FBC 1609.4.3), as defined by the Designer of Record and acceptable to the Authority Having Jurisdiction. Maximum Ultimate Wind Speeds noted herein are limited to projects meeting the following: ✓ Maximum height of 30 ft ✓ Enclosed building (Internal Pressure Coefficient, GCpi = + 0.18); ✓ Site conditions and location of the structure do not meet all conditions specified in Section 26.8.1 of ASCE 7-10 (Kzt = 1.0). Analysis for buildings falling outside these constraints shall be on a project-by-project basis by a Florida Registered PE. NEMO|etc. NEMO ETC, LLC Evaluation Report 9915.06.16-R4 for FL20742-R4 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 4: 02/21/2019 Prepared by: Robert Nieminen, PE-59166 Plycem USA LLC; (281) 813-1260 Appendix 1, Page 2 of 6 TABLE 1: ALLURA™ PANEL SIDING FACE FASTENED TO FRAMING System No. Max. Width (in) Substrate (Note 1) Siding Attach MDP (psf) Ultimate Wind Speed (mph) (Note 5) Framing/Sheathing Max. Spacing (in) Type Fasteners (Note 2) Spacing Exposure B Exposure C Exposure D 1. 48 Min. 20 ga. steel stud with nominal 5/8” plywood sheathing 16 Face fastened to framing ITW Buildex Rock- On® Type S 2PWH HI-LO® CLC, 9-15 x 2¼" (Part No. 2155500) 6-inch o.c. along panel edges; 6-inch o.c. along interior framing -38 162 137 126 2. 48 2x4 Spruce-Pine-Fur with nominal 5/8” plywood sheathing 16 Face fastened to framing 6d common nails, min. 2" long x 0.113" shank dia. x 0.265" head dia. 6-inch o.c. along panel edges; 6-inch o.c. along interior framing -38 162 137 126 NEMO|etc. NEMO ETC, LLC Evaluation Report 9915.06.16-R4 for FL20742-R4 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 4: 02/21/2019 Prepared by: Robert Nieminen, PE-59166 Plycem USA LLC; (281) 813-1260 Appendix 1, Page 3 of 6 TABLE 2A: ALLURA™ LAP SIDING BLIND FASTENED TO FRAMING System No. Max. Width (in) Substrate (Note 1) Siding Attach MDP (psf) Ultimate Wind Speed (mph) (Note 5) Framing/Sheathing Max. Spacing (in) Type Fasteners (Note 2) Exposure B Exposure C Exposure D 3. 8¼ Min. 20 ga. steel stud 16 Blind fastened to framing Min. #8 x 1 5/8 inch long self-tapping screws with a 0.375 inch dia. wafer head -22 123 N/A N/A 4. 8¼ 2x4 Spruce-Pine-Fur 16 Blind fastened to framing Ring shank roofing nails, min. 1¾" long x 0.120" shank dia. x 0.375" head dia. -23 126 107 N/A 5. 7¼ 2x4 Spruce-Pine-Fur with nominal 1/2” plywood sheathing 16 Blind fastened to framing Ring shank roofing nails, min. 1¾" long x 0.120" shank dia. x 0.375" head dia. -27 137 116 106 6. 6¼ 2x4 Spruce-Pine-Fur 16 Blind fastened to framing Ring shank roofing nails, min. 1¾" long x 0.120" shank dia. x 0.375" head dia. -36 158 133 123 7. 5¼ 2x4 Spruce-Pine-Fur 16 Blind fastened to framing Ring shank roofing nails, min. 1¾" long x 0.120" shank dia. x 0.375" head dia. -38 162 137 126 TABLE 2B: ALLURA™ LAP SIDING FACE FASTENED TO FRAMING System No. Max. Width (in) Substrate (Note 1) Siding Attach MDP (psf) Ultimate Wind Speed (mph) (Note 5) Framing/Sheathing Max. Spacing (in) Type Fasteners (Note 2) Exposure B Exposure C Exposure D 8. 9¼ Min. 20 ga. steel stud with nominal 5/8” plywood sheathing 16 Face fastened to framing ITW Buildex Rock-On® Type S-12 2PWH CLC, 8 x 2¼" (Part No. 2139500) -46 178 151 139 9. 9¼ 2x4 Spruce-Pine-Fur with nominal 5/8” plywood sheathing 16 Face fastened to framing 8d common nails, min. 2½" long x 0.134" shank dia. x 0.281" head dia. -58 200 169 156 NEMO|etc. NEMO ETC, LLC Evaluation Report 9915.06.16-R4 for FL20742-R4 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 4: 02/21/2019 Prepared by: Robert Nieminen, PE-59166 Plycem USA LLC; (281) 813-1260 Appendix 1, Page 4 of 6 TABLE 2C: ALLURA™ LAP SIDING BLIND FASTENED TO SHEATHING System No. Max. Width (in) Substrate (Note 1) Siding Attach MDP (psf) Ultimate Wind Speed (mph) (Note 5) Framing Max. Spacing (in) Sheathing Method Fasteners (Note 2) Spacing (inch o.c.) Exposure B Exposure C Exposure D 10. 9¼ 2x4 Spruce- Pine-Fur 24 Min. 7/16- inch OSB Blind fastened to sheathing Ring shank roofing nails, min. 1¾" long x 0.120" shank dia. x 0.375" head dia. 8 -33 151 128 117 11. 8¼ 2x4 Spruce- Pine-Fur 24 Min. 7/16- inch OSB Blind fastened to sheathing Ring shank roofing nails, min. 1¾" long x 0.120" shank dia. x 0.375" head dia. 12 -28 139 118 108 12. 8¼ 2x4 Spruce- Pine-Fur 16 Min. 7/16- inch OSB Blind fastened to studs and to sheathing between studs Ring shank roofing nails, min. 1¾" long x 0.120" shank dia. x 0.375" head dia. 8 -38 162 137 126 13. 8¼ 2x4 Spruce- Pine-Fur 24 Min. 7/16- inch OSB Blind fastened to sheathing Ring shank roofing nails, min. 1¾" long x 0.120" shank dia. x 0.375" head dia. 8 -41 169 142 131 14. 8¼ 2x4 Spruce- Pine-Fur 16 Min. 7/16- inch OSB Blind fastened to sheathing Ring shank roofing nails, min. 1¾" long x 0.120" shank dia. x 0.375" head dia. 6 -56 197 166 153 15. 7¼ 2x4 Spruce- Pine-Fur 16 Min. 15/32- inch plywood Blind fastened to studs and to sheathing between studs Ring shank roofing nails, min. 1¾" long x 0.120" shank dia. x 0.375" head dia. 8 -57 199 168 154 NEMO|etc. NEMO ETC, LLC Evaluation Report 9915.06.16-R4 for FL20742-R4 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 4: 02/21/2019 Prepared by: Robert Nieminen, PE-59166 Plycem USA LLC; (281) 813-1260 Appendix 1, Page 5 of 6 TABLE 2D: ALLURA™ LAP SIDING BLIND FASTENED TO FRAMING & FURRING STRIPS System No. Max. Width (in) Substrate (Note 1) Siding Attach MDP (psf) Ultimate Wind Speed (mph) (Note 5) Framing Max. Space (in) Sheathing Furring Strips Method Fasteners (Note 2) Spacing (inch o.c.) Exposure B Exposure C Exposure D 16. 9¼ 2x4 Spruce- Pine-Fur 24 Min. 7/16- inch OSB 1x4-inch PT furring strips, 12-inch o.c. Blind fastened to furring strips Ring shank roofing nails, min. 1¾" long x 0.120" shank dia. x 0.375" head dia. 12 -21 121 N/A N/A 17. 9¼ 2x4 Spruce- Pine-Fur 24 Min. 7/16- inch OSB 1x4-inch PT furring strips, 8-inch o.c. Blind fastened to furring strips Ring shank roofing nails, min. 1¾" long x 0.120" shank dia. x 0.375" head dia. 8 -40 166 141 129 TABLE 2E: ALLURA™ LAP SIDING BLIND FASTENED TO VERTICAL BATTENS System No. Max. Width (in) Substrate (Note 1) Siding Attach MDP (psf) Ultimate Wind Speed (mph) (Note 5) Wall Vertical Battens Batten Spacing (inch o.c.) Batten Fasteners Batten Fastener Spacing (inch o.c.) Method Fasteners (Note 2) Spacing (inch o.c.) Exposure B Exposure C Exposure D 18. 7¼ CMU block 1x4-inch PT Spruce- Pine-Fir (SPF) 16 ¼” diameter threaded concrete anchor, min. 1¼” embedment Max. 12 Blind fastened to battens Ring shank roofing nails, 1¼" long x 0.120" shank dia. x 0.375" head dia. 16 -40 166 141 129 19. 7¼ CMU block 1x4-inch PT Southern Yellow Pine (SYP) 16 ¼” diameter threaded concrete anchor, min. 1¼” embedment Max. 12 Blind fastened to battens Ring shank roofing nails, 1¼" long x 0.120" shank dia. x 0.375" head dia. 16 -52 190 160 147 NEMO|etc. NEMO ETC, LLC Evaluation Report 9915.06.16-R4 for FL20742-R4 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 4: 02/21/2019 Prepared by: Robert Nieminen, PE-59166 Plycem USA LLC; (281) 813-1260 Appendix 1, Page 6 of 6 TABLE 3: ALLURA™ SHAPES SIDING BLIND FASTENED TO FRAMING System No. Max. Width (in) Substrate (Note 1) Siding Attach MDP (psf) Ultimate Wind Speed (mph) (Note 5) Framing/Sheathing Max. Spacing (in) Type Fasteners (Note 2) Exposure B Exposure C Exposure D 20. 16 Min. 20 ga. steel stud with nominal 5/8” plywood sheathing 16 Blind fastened to framing ITW Buildex Rock-On® Type S-12 2PWH CLC, 8 x 2¼" (Part No. 2139500) -48 182 154 142 21. 16 2x4 Spruce-Pine-Fur with nominal 5/8” plywood sheathing 16 Blind fastened to framing 8d common nails, min. 2½" long x 0.134" shank dia. x 0.281" head dia. -48 182 154 142 NEMO|etc. NEMO ETC, LLC Evaluation Report 9915.06.16-R4 for FL20742-R4 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 4: 02/21/2019 Prepared by: Robert Nieminen, PE-59166 Plycem USA LLC; (281) 813-1260 Appendix 2, Page 1 of 2 APPENDIX 2: ALLOWABLE SHEAR LOADS FOR PANEL SHEAR WALLS Table Type Application Fastener Engage 4A Allura™ Panel Siding Face Fastened Wood Framing 4B Allura™ Panel Siding Face Fastened Steel Framing The following notes apply to the systems outlined herein: 1. Shear load data are based on ASTM E72 testing at an ISO 17025 accredited laboratory, and are offered within this Evaluation Report at the request of the applicant. 2. All board edges shall be supported by framing. Panels shall be applied with the long dimension either parallel or perpendicular to studs. 3. The maximum height-to-length ratio for use of this data is 2:1. 4. Allowable shear loads are based on a 3 to 1 margin of safety. 5. For steel framed assemblies in Table 4B, allowable loads are offered for the panel-siding itself and based on the average test load at 1/8-inch net deflection, with the lesser of the two highlighted red. TABLE 4A: ALLURA™ PANEL SIDING FACE FASTENED TO WOOD FRAMING System No. Max. Width (in) Substrate Siding Attach Ultimate Shear Load (plf) Allowable Shear Load (plf) Framing/Sheathing Max. Spacing (in) Fasteners Spacing (inch o.c.) Panel Edges Interior Framing 1. 48 2X4 wood, Hem-Fir 16 6d common nails 6 6 541 180 2. 48 2X4 wood, Hem-Fir 16 6d common nails 4 4 694 231 3. 48 2X4 wood, Hem-Fir 24 6d common nails 6 6 490 163 4. 48 2X4 wood, Hem-Fir 24 6d common nails 4 4 622 207 NEMO|etc. NEMO ETC, LLC Evaluation Report 9915.06.16-R4 for FL20742-R4 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 4: 02/21/2019 Prepared by: Robert Nieminen, PE-59166 Plycem USA LLC; (281) 813-1260 Appendix 2, Page 2 of 2 TABLE 4B: ALLURA™ PANEL SIDING FACE FASTENED TO STEEL FRAMING System No. Max. Width (in) Substrate Siding Attach Panel Performance Performance at 1/8” Net Deflection Framing/Sheathing Max. Spacing (in) Fasteners Spacing (inch o.c.) Panel Edges Interior Framing Ultimate Shear Load (plf) Allowable Shear Load (plf) Test Load (lbf) Shear Load (plf) 5. 48 Min. 20 ga. steel x 3.625 in. x 1.375 in. steel studs 16 #8-18 x 1-5/8" Phillips Wafer Head w/ Nibs self-drilling cement board screws 6 6 729 243 2483 310 6. 48 Min. 20 ga. steel x 3.625 in. x 1.375 in. steel studs 24 #8-18 x 1-5/8" Phillips Wafer Head w/ Nibs self-drilling cement board screws 6 6 591 197 2500 313 7. 48 Min. 20 ga. steel x 3.625 in. x 1.375 in. steel studs 16 ET&F Fastening Systems: Trimfast Pins AST-100 4 8 503 168 1117 140 8. 48 Min. 20 ga. steel x 3.625 in. x 1.375 in. steel studs 24 ET&F Fastening Systems: Trimfast Pins AST-100 4 8 473 158 1067 133