Loading...
330 17th St ACC21-0048 PERGOLA • iY.- Building Permit Application Updated 10/9/18 , e City of Atlantic Beach Building Department **ALL INFORMATION 800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY �� 191' IS REQUIRED. Phone: (904) 247-5826 Email: Building-Dept@coab.us 7 t ���/� Job Address: 3 3j0 / 7L 5 ! , /4 <- .( c t f_L- Permit Number: a0 Z I - 00 Legal Description 3.1/-5/ (%`/ 4s.--,X9 5 6hv4 mfil-it./.v.4 r-lAtJ,/P6 La f`t` RE# / 7,2 e7.10-d Valuation of Work(Replacement Cost)$ *3 Q`/ ,.Dc--3 Heated/Cooled SF Non-Heated/Cooled • Class of Work: 1254ew ❑Addition ❑Alteration ❑Repair EMove ❑Demo ❑Pool ❑Window/Door • Use of existing/proposed structure(s): ❑Commercial L*J'Residential • If an existing structure,is a fire sprinkler system installed?: ❑Yes Plqo • Will treels) be removed in association with proposed proiect? ❑Yes(must submit separate Tree Removal Permit) •21 to Describe in detail the type of work to be performed: re--) /.--6( ,r Pr- ,t c t7 c> I L 1l c. /0 ')C is a Florida Product Approval# for multiple products use product approval form Property Owner Information Name j/./i4-A-r,f-rt / Z/4-/L1 C-4-S/.AL Address 3 30 7 _s---- city City 4-7/_,4- 7‘c /3G c l--1 State f— Zip 321.35 Phone %moi/ -.2 l- .3r T7-44 E-Mail p m. S/4-d x30{� Tr 'y,4i-Mo . ,P4-t Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) Contractor Information Name of Company Qualifying Agent Address City State Zip Office Phone Job Site Contact Number State Certification/Registration# E-Mail Architect Name&Phone# Engineer's Name&Phone# Workers Compensation Insurer OR Exempt "Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE:In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTI , 0 COMMENCEMENT. .X,:%...: -ti f - , (Signature .f Owner or Agent) 7 (Signature of Contractor) Signed and sworn to(or of .)before me this ' ay of -Signed and sworn to(or affirmed)before me this day of a' ,-. 0 ,b l�'C�• ` 4 r- , ,by MEM lirW (Signature of Notary) �,{;v�u'•' TONIGINDLESPERGER [ ]Personally Known OR :R.. • MY COMMISSIOI�Jk� "K•,wn OR [ ]Produced Identification `.tc , f,�`eo EXPIRES:O401164 Q0W Id: tification Type of Identification: ..•o. „ °wryT3dplttl(iddlAfi lk: ion: Owner Builder Affidavit **ALL INFORMATION HIGHLIGHTED IN City of Atlantic Beach Building Department GRAY IS REQUIRED. 800 Seminole Rd, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT#:11)- Z I I. FLORIDA STATUTES; CHAPTER 489, FLORIDA STATUTES, PART 1 "CONSTRUCTION CONTRACTING" REQUIRES OWNER/ BUILDER TO ACKNOWLEDGE THE LAW: DISCLOSURE STATEMENT FOR SECTION 489.103(7), FLORIDA STATUTES: STATE LAW REQUIRES CONSTRUCTION TO BE DONE BY LICENSED CONTRACTORS. YOU HAVE APPLIED FOR A PERMIT UNDER AN EXEMPTION TO THAT LAW. THE EXEMPTION ALLOWS YOU, AS THE OWNER OF YOUR PROPERTY,TO ACT AS YOUR OWN CONTRACTOR EVEN THOUGH YOU DO NOT HAVE A LICENSE. YOU MUST SUPERVISE THE CONSTRUCTION YOURSELF. YOU MAY BUILD OR IMPROVE A ONE OR TWO FAMILY RESIDENCE OR A FARM OUTBUILDING. YOU MAY ALSO BUILD OR IMPROVE A COMMERCIAL BUILDING AT A COST OF$25,000.00 OR LESS. THE BUILDING MUST BE FOR YOUR USE AND OCCUPANCY. IT MAY NOT BE BUILT FOR SALE OR LEASE. IF YOU SELL OR LEASE A BUILDING YOU HAVE BUILT YOURSELF WITHIN ONE YEAR AFTER THE CONSTRUCTION IS COMPLETE,THE LAW WILL PRESUME THAT YOU BUILT IT FOR SALE OR LEASE,WHICH IS IN VIOLATION OF THIS EXEMPTION. YOU MAY NOT HIRE AN UNLICENSED PERSON AS YOUR CONTRACTOR. YOUR CONSTRUCTION MUST BE DONE ACCORDING TO THE BUILDING CODES AND ZONING REGULATIONS. IT IS YOUR RESPONSIBILITY TO MAKE SURE THAT PEOPLE EMPLOYED BY YOU HAVE LICENSES REQUIRED BY STATE LAW AND BY COUNTY OR MUNICIPAL LICENSING ORDINANCES. II. INJURY LIABILITY; SINCE OWNERS MAY BE LIABLE FOR INJURIES TO WORKERS THEY HIRE,THE BUILDING DEPARTMENT SUGGESTS WORKER'S COMPENSATION INSURANCE BE PURCHASED. . III. IRS WITHHOLDING; OWNERS HIRING WORKERS BECOME EMPLOYERS AND SHOULD ALSO OBSERVE IRS WITHHOLDING TAX AND/OR FORM 1099 REQUIREMENTS ON THE WORKERS THEY EMPLOY ON THEIR IMPROVEMENT TRADES. IV. PENALTY; UNLICENSED CONTRACTORS CANNOT BE EMPLOYED UNDER ANY CIRCUMSTANCES. OWNERS BEING SUBJECT TO $5,000 PENALTY UNDER FLORIDA STATUTE NO. 455-228(1). AN "OCCUPATIONAL LICENSE" IS NOT ADEQUATE. THE OWNER SHOULD PHYSICALLY SEE THE COUNTY "CERTIFICATE OF COMPETENCY" OR THE FLORIDA"CONTRACTORS CERTIFICATE" TO ASCERTAIN IF A PERSON ISA LICENSED CONTRACTOR. CONTACT THE BUILDING DEPARTMENT(904- 247-5826 OR BUILDING-DEPT@a COAB.US ) IF IN DOUBT. V. ACKNOWLEDGEMENT; I HEREBY ACKNOWLEDGE THAT I HAVE READ THE ABOVE DISCLOSURE STATEMENT AND THAT I COMPLY WITH ALL THE REQUIREMENTS FOR THE ISSUANCE OF AN OWNER-BUILDER PERMIT. Job Address: 330 17th Street.Atlantic Beach, FL 32233 Owner Name:William F. Lancaster Phone Number: (904)241-3994 Mailing Address: 330 17th St City: Atlantic Beach State: FL Zip: 32233 Notarized Signature of Owner of e•for�goin instrument was acknowledged before me this day of , 3C 20-2- (in the State of Florida, County Signature of Notary Public — 57:: [ ] Personally Known OR [ ] Produced Identification Type of Identification: LI tiyam,. TONI GINDLESPERGER Updated 10/24/18 MY COMMISSION#GG 353178 1P EXPIRES:October 6, 023 �=°�` Bonded Thru Notary Public Underwriters Back 2020 FBC Deluxe Layout V1 (Sealed) (1).pdf 1 i _1_1 __ -- - .' J'x.120•Rlrg Shank G•Ivawed Nails •1 ea 2'x2'strip,es loin 1 I _ __T�,_ 2•x.120'0.b/Shank Galvanised fouls /_'� —��� .1 ea aIle of each Joist Mga—. ,lea 5/8"111 Thread Poda SP I � It �—� - wrth nun ane we.nen 7'x.120'Rlnq Shenk Wlvanixed Nails, I � •e k«Meatier[o port 1 m i...... �'e•m Po: �----- �-�- Jr1•1 Doc amau o 0% t Rad 1 I I Coes.2020 Monde Building Code 7th Station 100%Western Rad Clear Dead Loads'MateNl Weight Structural Grade,Pull \ Roof Live uP.10 PSF Dimension Sawn Sixes oat SO Meader Allowable Soli Nanau,4ny Preen:1500 Pgf-6x6 p - Y 18'M Max Wind Speed 140 MPM-2x8 double headers Concrete ComPr«eM Strength:Fc.2500eS1-21,6 foist lb"gets -- CEDAR"STRUCTURAL SELECT'-2x2 stripping 6'p.c. 7"x.120'ring Shenk G•Ivantxed Nails,61e,--.-- -• Fb•1000 PSI-5/B"all thread bolts aide,total 12_______ Fv•155 PSI-I'x.120'dla.Tiny shank Simpson ABU660.2'� Vl %an VNw Fc•425 PSI galvenixed nails Fel•1000 PSI E_ .1st PSI c aaa .G 1q., Simpson N'Wedge An[noEll } sz«w•.u•wa.r each�d ti cam non oeet eumtveend».ka er o..< "ry II y.I4 g t Tri.nnpw Mw,e we hMN 4 wgy k 2,G —k AF.r ame^oe arm»d.de and leo smnavedust esrnew • ,6•ae• • Puatmuatb•laatorted Gab edge VS. *Milt /�I�1� 11�s'' est ekcvv,x rwxaa df 11'wa •rm control Joint or Gab edge '''�D�wsl�f1ieg t•` —2'x,120•ring Sh.n�tgadvanl0W Nelle,baa aide,total 12 /( 18'Max K 18' - �.... Slmpron 0605656 ;'-'.111MIMI•1111= 111•111=11111111111Mg/ _ Slmpron N'Wedge Mtlgr,1 ea II 1� IIIZalnlnpShb 4•Mln�paall Simesen Anchor on Slab m Power Nom]«IThkYMnla i a 18'M. 6 x Gr,dn R317.1.2 Geographical In Geographical whr•experience Ready Mu Concrete hes demonstrated a epeCiflc need, 2"From Grade approved naturally durable or pre• 25eure• 2500P6I preservative-treated wood shell b•peed for those portions of wood member.that t 1 Front view t..l ak'%, form ih•structural«pporte of buildings, l !A beknnles,porches or•impar permanent Q Vet12 building sppurteance*when thou 7' (.4)0.CW members ere exposed to the w«Mer ' equally spaced without ede.eat•protection from a roof, J 30. 2,, overhang q other covering that would fv prevent molaur,or water.6w..1l accumulation n n —1,2' n the surface or at Jolnte between bars. Minimum 1500 PSF O2 Oatell Post In Ground Soil 11•1649 Capacltr CUSTOMER I iNGSk BACKYARD Storage SDlutlone,LLC [RRiTGRR' P a oBeEiF2Fff8"ri oPnoxg -— MM l ale nen Generic 18x18 Deluxe Remota DESIGNER W3440 St John's ParkWp OPTION/ Glen Johnson K�M OP WORK Sanford,FL 32771 e'•X- strains In Pawns wan Eder. 225.205.8852 MAP SHOWING BOUNDARY SURVEY OF LOT 9, BLOCK 13, ACCORDING TO THE PLAT OF SEL.VA MARINA. UNIT NO, 6. AS RECORDED N PLAT BOOK 34, PAGE(S) 51, 51A & 51B OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA. CERTIFIED T0: WILLIAM F. LANCASTER SR AND MARGARET L. LANCASTER, VYSTAR CREDIT UNION, FIDELITY NATIONAL TITLE INSURANCE COMPANY AND VYSTAR TITLE AGENCY SEA OATS DRIVE (60' RIGHT Or WAY) !,Ar?if S 06'32'03' E 64.45'(M) a� PT S 06'16'10"--E „Ii. 4-x4- 64.71' (R) - ,,,I `. c CONCRETE 1/2- -7, ,,',„,1417,,,,k 90 TH MONUMENT1\1 n IRON PIPE O.O7 CO I• Jf T yo yN �� 1.--u ! J ° ° t j la.-0.2' C, AFL 7... I o 2 27 . .c .8• • • CPEO o 30' BRL IRON PIPE PC ( 7• I n ' : h5 Q o D CY N ] to kft 27.9' 7.4' M '�, COtI0.'`. '- 12.1' O �f Illi CfRE TTI WALK _ Y'M 0 y U - 03 Z b M T O J ` u II i m r ¢U 12.1 y i (/3 �'� 0 5 8. o p O',„ W� Jho 330.0' _ 7 m n p ^W M 4 F- ▪ ��ts u°I ¢ OF ti ju v'ANYL i+1 0 n r SHED CO k )E , w W , w WOOD a w 5 �+ rc s ! ' 29.9' 11.8' 5 FLOOR = (/) W 3 i O Ei .. n °' 12.3' b �d ra M -',2 i� 4.0' L'',-Ji 5.1' o o N -''_ z .,/ b m N Dy-1.9' y� ry 0 IC37.8• 33.1n 5 ' V Z ALL°( ao'°: 'ice--0.9' 6J j �� U Y WALL U L U J U 0.7' r -IRO. N 06'16'10" W 94.71' (R) IRON PIPE I N 0611'4.9' W 94.46' (M) LOT B, BLOCK 13 LOT 7, BLOCK 13 ROOD 2DYE 'Ir'-AREAS,DETERMINED TO DE LL1SID PIE 0.25 ANNUAL aIPNCE FLCOO PLAIN/F1000 ZONE"8(SHAD©)"-AREAS OF O2X ANNUAL CHANCE FLOOD.AREAS C4 It ANNUAL CHANCE 44TH AVERAGE DEPTHS OF LESS THAN t FOOT OR MT"DRAINAGE AREAS LESS THAN 1 50UA0E WEE, AND ARrAS PROTECTED BY LEVEES FROM 1S ANNUAL CHANCE FLOOD. V E ' 0 GENERAL NOTES: J 9. % R s I.REARIN05 ARE BASED ON RAT BOOK 34. PACE 5IA L STRUCTJRE,43„.5-..-1_.0 SHORN!IFEP1 LLS 1111I9!FLOOD ZONE X AS BEST 0(10010461) C3 FROI FE.M.A FLOOD ALAPS PANE1 N0.409 DATED-CA-03-2013 A SSOCIATED SURVEYORS INC. GS.PIPES AND SURFACE ' L°; NENT��"DERGROUND A 1,01 ;„=�R Q 4./ A LAND 1G ENGINEERING SURVEYS 5.1)85 SURVEY BASED CN LEGAL DESCRIPTIONS FUR10500. TIE 00)9(0 RECORDS AEU lal i• NOT SEARCHED BT PMI5 SURVEYOR FOR(MORRIS.TITHE.OVENAATS.B.R.L'5 F.- 3846 BLANDING BOULEVARD RESTRICTIONS,CLOSURES,TAXINGS OR ORDINANCES,ETC. B.TIE HEAVY LEVE%CM HEREON,MAY NOT DIpGTE ACTUAL ORSRSHP. A. JACKSONVILLE, FLORIDA 32210 T.UNLESS ORIERSISE STATED ALL IRON PIPES FOUND HAVE NO IDENTIFICATIOE 904-771-6466 J j L AC AIR BRE BUILDING RESTRIRCTIGN LINE PSN =PROFESSIONAL SURVEYOR 1 POPPER CERTIFICATE OF AUTHORIZATION NO. LB 0005488 E BT BUILDING TIE R =RADIUS ANA.= S S V 0 BTN BEIVEEN {R> RECORD E (D COVENTEDANT FROM RECORDSTRICT RLS •REGISTERED LAND SURVEYOR N Cd1 COVENANTS L RESTRICTIONS P/N =RIGHT OF VAT I HEREBY CERTIFY THIS SURVEY WAS DONE UNDER MY D r cp DBIr REAR (Trp, =TYPICAL DIRECT SUPERVISION AND MEETS THE MINIMUM TECHNICAL tact CONCRETE 0 a2T WON PIPC(4')OR ROOK/ STANDARDS FOR LAND SURVEYING PURSUANT TO CHAPTER 5J-17.050 3 EBD ELECTRIC TIm 5480 I . . . .F ;. CR U3.O p0, THROUGH .052. FLORIDA ADMI TRA E COOS. CH-• ER 472. Z. A .SEA ELECTRIC IRARAU_E ELECTRIC 1.PAUT�iaalTY ' '''''''An G°"cRETE w3NUNEMT(w) / 9 L LENLTI OF ARC S CRT OR AA b DISC �' / / B LD LICENSED BUSINESS - _ _ FENCE R LS L[CETKED SurvEYIIR -4--r--X--X--E-R-R- M FENCE�y�,�,. (M: -HEAStM£D V V Y Y 'V V Y AWE FLNOE BY: � i v - �E NSD NAIL S Di SL CHA LES �. HATCHER Fryry if. CERTIFICATE •9. 3771 V OtR OFFICIAL REEVRDS OCE, M00D Twct ryry�III���p.�����I��` ( 172V OFFIC1AL RECORDS Y9UP£ Vlsw C LES L. STARLING IDA CERTIFICA ' NO. 4579 A pC POINT ar ELswE OVFFHEAD Um'mr PCC POINT OF CpPGisiD CURVE FFE NE FtsEP RA MOND J. SCHAEFER LORIDA CERTIFICA NO. 6132 T o '�E°+� PEO POIN ERIN INTER PAT WATER METER I P1 POINT Of IMTFRSECi1WR CEO PRL DODO OF REVERSE CURVE '�' UTAH'DOLE JOB NO. 71622 DATE 03-14-2018 N PRN PREFERENCE NONUPEMT B DLETM " SCALE: 1" = 30' DRAFTER WF S PT POINT OF OF TANGENCY F. . PLO PROFESSIONAL LAND StAVETOR A- - CENTRAL ANGLE NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER • PERGOLAS DELIVERY & INSTALLATION INCLUDED ¢ ax. 1 -,o"f- + _r R... A tir 410bn-1i. to) -k. . , , 1 rte. .. _ ; ..) STANDARD I I DELUXE I SADDLE POS - -,TARTING AT STARLING AT STARTING AT $ 2 , 299 $ 3 , 399 $ 4 , 199 r7"14v _„,_ 177Sha Shade Shade • cEntry level pergola Great value pergola Premium pergola Medium 4x4 solid wood posts Large 6x6 solid wood pc_:_ 8x8 3-pc post 2x8 single headers 2x8 double headers 4x10 single headers Size SizeSize (Wxl) Douglas Fir Western Red Cedar (Wxl) Douglas Fir 1..'- Red Cedar (WXL) Douglas Fir Wes•— 10x10 $ 2,299 5 3.499 10x10 $ 3,399 $ 5.199 10x10 $ 4,199 S 6 10x12 $ 2,999 5 3.799 10x12 $4,39 5 5,699 10x12 $ 5,399 5 7. 10x14 $ 3,299 S 4.299 12x12 $ 5,099 5 6.499 12x12 $ 5.799 $ 12x12 $ 3.499 5 4.399 10x16 $ 5,199 $ 6.599 10x16 $ 6,399 5 B. 12x14 $ 4,299 5 5.499 12x16 $ 6,199 S 7.799 12x16 $ 6,699 59.• 14x14 $ 5.599 5 7.099 16x16 $ 7,299 5 9.399 ( 12x20 $ 7,999 5 10 ADD STAIN STAIN CHOICES TO ANY STRUCTURE IBROWNI I .:. RAlI I RED I Pavilion posts are typically 1'inside the roof ^a CEDAR I { $4.25 For example.if your pavilion canopy is 14'x 14. 1-21 2 1 P ER 5 Q F T your post footprint will be 12'x 12'.