372 Ahern St RES21-0262 Int Repairs, Ext HandrailOWNER:ADDRESS:CITY:STATE:ZIP:
869 873 & 877 CHARLES
ALLEN DRIVE LLC ET AL 2000 CHEROKEE LN NEPTUNE BEACH FL 32266
COMPANY:ADDRESS:CITY:STATE:ZIP:
3RD LITTLE PIG
CONTRACTOR 5078 YERKES ST JACKSONVILLE FL 32205
TYPE OF
CONSTRUCTION:
REAL ESTATE
NUMBER:ZONING:BUILDING USE
GROUP:SUBDIVISION:
169733 0010 ATLANTIC BEACH
JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK:
372 AHERN ST RESIDENTIAL ALTERATION
RESIDENTIAL
INTERIOR REPAIRS AND
EXTERIOR HANDRAIL $20000.00
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
BUILDING PERMIT 455-0000-322-1000 0 $155.00
BUILDING PLAN CHECK 455-0000-322-1001 0 $77.50
STATE DBPR SURCHARGE 455-0000-208-0700 0 $3.49
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.33
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN
YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT
MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU
INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT.
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
1 of 2Issued Date: 8/27/2021
PERMIT NUMBER
RES21-0262
ISSUED: 8/27/2021
EXPIRES: 2/23/2022
RESIDENTIAL PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
TOTAL: $238.32
2 of 2Issued Date: 8/27/2021
PERMIT NUMBER
RES21-0262
ISSUED: 8/27/2021
EXPIRES: 2/23/2022
RESIDENTIAL PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
DESCRIPTION ACCOUNT QTY PAID
PermitTRAK $238.32
RES21-0262 Address: 372 AHERN ST APN: 169733 0010 $238.32
BUILDING $155.00
BUILDING PERMIT 455-0000-322-1000 0 $155.00
BUILDING PLAN REVIEW $77.50
BUILDING PLAN CHECK 455-0000-322-1001 0 $77.50
STATE SURCHARGES $5.82
STATE DBPR SURCHARGE 455-0000-208-0700 0 $3.49
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.33
TOTAL FEES PAID BY RECEIPT: R16884 $238.32
Printed: Friday, August 27, 2021 8:51 AM
Date Paid: Friday, August 27, 2021
Paid By: 3RD LITTLE PIG CONTRACTOR
Pay Method: CREDIT CARD 503431710
1 of 1
Cashier: CG
Cash Register Receipt
City of Atlantic Beach
Receipt Number
R16884
Final Plumbing
Final Electrical
Final HVAC
CC Final
Final Building*
Swimming Pool Steel
Swimming Pool Safety
Electrical Grounding & Bonding
Swimming Pool Final (Bldg)
Swimming Pool Final (PW)
Formed Columns/ Beams*
Masonry Cell Fill
Structural Steel*
OTHER:
OTHER:
OTHER:
OTHER:
OTHER:
Power Pole
Silt Fence
Piers/ Stem Walls
Underground Plumbing
Underground Electric
Foundation/ Footing
Slab**
Retaining Wall Footing
Driveway
Sewer (Building Dept)
Sewer Tap (Utilities Dept)
Rough Electric*
Rough Plumbing/ Top Out*
Rough Mechanical*
House Wrap
Wall Sheathing
Roof Sheathing
Tie-down Framing Connections
Rough Framing
Roofing In Progress
Window/Door In-Progress
Insulation Ceiling
Insulation Wall
Exterior Lath
Stucco Scratch Coat
Exterior Siding In-Progress
Brick Flashing & Ties
Early Power
Gas Rough
Gas Final*
* When all rough electric, plumbing, mechanical are complete but before any work is
covered up.
* When all gas piping is complete and wallboard is installed but before gas is
attached to any appliance. All outlets must be capped and pipe pressurized at a
minimum of 15 lbs.
* For new living space: When all construction work including electrical, plumbing,
mechanical, exterior finish, grading, required paving and landscaping is complete
and the building is ready for occupancy, but before being occupied
Additional inspections may apply to your project if your project
contains these elements:
INSPECTIONS REQUIRED FOR BUILDING PERMITS
To verify compliance with building codes, inspections of the work authorized are required at various points of the construction.
The following inspections are typically required for residential projects:
Date: Initial: Date: Initial:
_____________________________________________________
Permit Type
____________________________________________________
Permit No.
__________________________________________________________
Job Address
____________________________________________________
Contractor
POST THIS CARD WITH PERMITS AND PERMIT
DOCUMENTATION IN FRONT OF BUILDING
Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends
Building Department Public Works/Utilities Fire Department
Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789
Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203
* When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all
electrical, plumbing and mechanical work is in place, but before concrete is poured.
* When all structural steel members are in place and all connections are complete,
but before such work is covered or concealed.
** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION
RES21-0262
RES21-0262NOT FILED
RES21-0262
372 Ahern St., A.B., Florida Permit # RES21-0262
Information from the 7th Edition of the FBC-Residential Code 2020.
R311.7Stairways.
R311.7.1Width.
Stairways shall be not less than 36 inches (914 mm) in clear width at all points above the permitted
handrail height and below the required headroom height. The clear width of the stairway at and
below the handrail height, including treads and landings, shall be not less than 311/2 inches (787
mm) where a handrail is installed on one side and 27 inches (698 mm) where handrails are provided
on both sides.
R311.7.5Stair treads and risers.
Stair treads and risers shall meet the requirements of this section. For the purposes of
this section, dimensions and dimensioned surfaces shall be exclusive of carpets, rugs or
runners.
R311.7.5.1Risers.
The riser height shall be not more than 73/4 inches (196 mm). The riser shall be measured vertically
between leading edges of the adjacent treads. The greatest riser height within any flight of stairs
shall not exceed the smallest by more than 3/8 inch (9.5 mm). Risers shall be vertical or sloped from
the underside of the nosing of the tread above at an angle not more than 30 degrees (0.51 rad) from
the vertical. Open risers are permitted provided that the openings located more than 30 inches (762
mm), as measured vertically, to the floor or grade below do not permit the passage of a 4 -inch-
diameter (102 mm) sphere.
R311.7.5.2Treads.
The tread depth shall be not less than 10 inches (254 mm). The tread depth shall be measured
horizontally between the vertical planes of the foremost projection of adjacent treads and at a right
angle to the tread’s leading edge. The greatest tread depth within any flight of stairs shall not
exceed the smallest by more than 3/8 inch (9.5 mm).
R311.7.8Handrails.
Handrails shall be provided on not less than one side of each flight with four or more
risers.
R311.7.8.1Height.
Handrail height, measured vertically from the sloped plane adjoining the tread nosing, or finish
surface of ramp slope, shall be not less than 34 inches (864 mm) and not more than 38 inches (965
mm).
Exceptions:
1. 1.The use of a volute, turnout or starting easing shall be allowed over the lowest tread.
2. 2.Where handrail fittings or bendings are used to provide continuous transition between
flights, transitions at winder treads, the transition from handrail to guard, or used at the start
of a flight, the handrail height at the fittings or bendings shall be permitted to exceed 38
inches (956 mm).
R311.7.8.3Grip-size.
Required handrails shall be of one of the following types or provide equivalent
graspability.
1. 1.Type I. Handrails with a circular cross section shall have an outside diameter of not
less than 11/4 inches (32 mm) and not greater than 2 inches (51 mm). If the handrail is
not circular, it shall have a perimeter dimension of not less than 4 inches (102 mm) and
not greater than 61/4 inches (160 mm) with a cross section of dimension of not more than
21/4 inches (57 mm). Edges shall have a radius of not less than 0.01 inch (0.25 mm).
2. 2.Type II. Handrails with a perimeter greater than 61/4 inches (160 mm) shall have a
graspable finger recess area on both sides of the profile. The finger recess shall begin
within a distance of 3/4 inch (19 mm) measured vertically from the tallest portion of the
profile and achieve a depth of not less than 5/16 inch (8 mm) within 7/8 inch (22 mm) below
the widest portion of the profile. This required depth shall continue for not less
than 3/8 inch (10 mm) to a level that is not less than 13/4 inches (45 mm) below the tallest
portion of the profile. The width of the handrail above the recess shall be not less than
11/4 inches (32 mm) and not more than 23/4 inches (70 mm). Edges shall have a radius
of not less than 0.01 inch (0.25 mm).