1927 Beach Ave RES18-0010 Blower Door o��ni • Permit #: r \ o«�r-� f Q • Blower Door Test Form Job Information Builder: �L eS GL,Airc SOI•S cav,,,x\oVeirS Community: Lot#: Address: I `1 ),11- T3 &4.. guL Unit#: City, State, Zip: r3'} .c1.04-i(_ 3QGIct FL �3-a33 Air Infiltration Test Results CFM(50)= 3C((4.4. 3 Volume = (Q O t 0a-c1 . O ACH(50) = CFM(50)X 60/Volume= 3. 145‘ KPass D Fail Passing results must be 7 ACH(50)or less Certification of Test Results R402.4.1.2 Testing.The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2,3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure or 0.2 inches w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7),F.S. or individuals licensed as set forth in Section 489.105(3)(f), (g), or (h) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Authorized Third Party I hereby certify the above results and that I hold the below certification: X Class A or B A/C contractor or Mechanical contractor License No. C.._Ae.ID cr(4Qck RESNET approved HERS Rater or Residential Field Inspector Certification No. BPI approved Building Analyst or Energy Auditor Certification No. Professional Engineer License No. Mechanical ve tila 'on s se.nailded: Yes No Signature: Printed Name: k-6304 S`oiAs J ir Date: glaaoZ� Revised 5/5/2017 Envelope Leakage Test Testing Company: Technician: Name: Indoor Comfort Consulting Inc. Name: Howard Stalls Address: 4040 Julington Creek Rd Credentials: CAC057409 Jacksonville , FL 32223 Email: howard@iccjax.com Phone: 904-219-7309 Building Information: Customer Information: Project ID: Tovey Name: James And Son Address: 1927 Beach AVE Address: Atlantic Beach, FL 32233 Geo-Tag Data: Latitude: Longitude: Timestamp: Measured Leakage: 3.48 ACH50 Test ID: Test 1 Purpose of Test: 50 Pa Env Leakage Measured CFM50: 3,944.3 Effective Leakage Area: 216.9 in2 Building Volume: 68,029.0 ft3 Enclosure Surface Area: 6,438.0 ft2 Coefficient(C): 310.2 Exponent(n): 0.650 (assumed) Test Standard: RESNET 380 One-Point Test Mode: Depressurize Test Characteristics: Indoor Temp: 76 °F Outdoor Temp: 87 °F Altitude: 20.0 ft Time Average Period: 10 seconds Test Date and Time: 2021-08-28 12:10:51 5000 4000 • Depressurize — 13 3000 cll rn as 2000 a) DI 00 1000 900 800 700 4 5 6 7 8 910 20 30 40 50 60 Building Pressure(Pa) Envelope Leakage Test Test Readings: Target(Pa) Bldg (Pa) Adj Bldg (Pa) Fan (Pa) Flow(cfm) Config Baseline 0.8 -50.0 -49.1 -49.9 -63.7 3,846.0 Open Fan Test Equipment: Flow Device: Model 3 110V Fan Serial#: 5515 Pressure Gauge: DG1000 Serial#: 5515 Calibration Date: 2020-03-19 Deviations from Standard: • None Comments: None Report by TEC Auto Test 1.8.0 (210),©2021 The Energy Conservatory, Inc. Page 2 of 2