Loading...
282 POINSETTIA ST ACC21-0049 -: 'f7. r. Building Permit Application Updated 10/9/18 City of Atlantic Beach Building Department **ALL INFORMATION V 800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY IS REQUIRED. Phone: (904) 247-5826 Email: Building-Dept@coab.us atc 1 , Job Address: c2 l"© 7 71 ��e / a, Il �I G� �Pe�i�Number: ' `O QZ i — X 4 9 Legal Description �W.t 5�V Se e_t i() `n. / 10,, 3 �'f c r RE# D (0I • i) Valuation of Work(Replacement Cost)$ '.. C',b� 5Heated/Cooled SF Non-Heated/Cooled • Class of Work: ❑New ❑Addition ❑Alteration ❑Repair ❑Move ❑Demo ❑Pool ❑Window/Door • Use of existing/proposed structure(s): ❑Commercial ,'Residential • If an existing structure,is a fire sprinkler system installed?: ❑Yes ❑No -IVA • Will tree(s) be removed in association with proposed project? ❑Yes(must submit separate Tree Removal Permit) OW o Describe in detail the type of work to be performed: !fix j A 4,,,,y. ra .' e et Florida Product Approval# for multiple products use product approval form Property Owner Information _ 1, Name GIC %-:t(t � C 6:1717)I S t .14r iy g I nAu ss aea Ps 1 5� e (7 icc S f' city /�1-10711 i c 6.ef z State FL Zip 3 a.�3 3 Phone 9j y. 171/A7---/ 3 '7 C? E-Mail t - Comte, 10�, l mas it C:OYY\ Owner or Agent(IrAgent, Power of Attorney or Agency Letter Required) Contractor Information —YAM Name of Company Qualifying Agent Address ,City State Zip Office Phone JO Site Contact Number State Certification/Registration# E-Mail Architect Name&Phone# Engineer's Name&Phone# Workers Compensation Insurer OR Exempt❑ Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDI G YOUR NOTICE OF COMMENCEMENT. (Signature of Owner or Agent) (Signature of Contractor) Signed a d sworn to(or .'firmed)before me this ti` day of Signed and sworn to(or affirmed)before me this day of P lc.' ' , • : r ' , , b OHM y _ :naa.-' . ary ii (Signature of Notary) [ ]Personally Known OR I ,, `:;f ., TONI G!NDLESPSRT rsonall(Known OR [ ]Produced Identification ,. k•� , MY COMMISSION#Cid BTINce:,Identification 1-°�`• "tl`••.io= EXPIRES:Cctober&p@23f Identification: Type of Identification: I-� .� _ 5,,. �� of c;; Bonded Thru Notary Public Underwriters s 1-IIJ3 , TREE & VEGETATION AFFIDAVIT FORINTERNALOFFICEUSEONLY " '�1 6 City of Atlantic Beach PERMIT# A7.3...40,_ Community Development Department 800 Seminole Road Atlantic Beach,FL 32233 ��t>>%' (P) 904-247-5800 SITE INFORMATION DATION ADDRESS t�o 0 f r T d2 &ci FL 3 D•DS 3 SUBDIVISION L "-,'o Se ( t) 071 ]'),-, SCI 'MI , f BLOCK LOT Cj y 0 RE# /I)Q S 0-ID0ao RESIDENTIAL ❑ COMMERCIAL ❑ OTHER APPLICANT INFORMATION NAME G/ ric c A44, ( K 1icr,Cn71 ( S PHONE# 7 d 11_7ve--/Y )0 ADDRESS Sa 'yr,e___ CELL# CITY STATE ZIP CODE EMAIL -- 1ot(` i 1st°, r q $8Z & mal 1, C p Y►'1 0OWNER ❑ LEGAL AUTHORIZED AGENT I affirm that I have reviewed the provisions of Chapter 23, "Protection of Trees and Native Vegetation", of the Municipal Code of Ordinances for the City of Atlantic Beach Florida and/or I have participated in a pre- application meeting with the Administrator of those regulations. Subsequently, I affirm that no regulated trees and no regulated vegetation will be damaged, destroyed and/or removed from the above-described property and/or adjacent properties including right-of-way. I HEREBY RTIFY THAT i, L INFORMATION PROVIDED IS CORRECT:Signature of Property Owner(s)or Authorized Agent N „ ,r K E Q0-` AY r � m;_s 9--3--a `l ° SIGNATURE OF APPLICANT PRINT OR TYPE NAMDATE SIGNATURE OF APPLICANT(2) PRINT OR TYPE NAME DATE Signed and sworn before me on this —3 day of ► ,2f:2 ( by State of f- ( County of L U ir _ I Identification verified: t J `----- Oath Sworn: ❑ Yes ❑ No -__C-SC:SCIC c_ ____ / Notary Signature '07, ' � •; ��y.; '' TCNI GINDLESPERGEP, 41_ ,'!k\ MY COMMISSION#GG 353178 My Commission expires "� ” EXPIRES:October 6,2023 04 TREE AND VEGETATION AFFIDAVh 01i'N'1318Bondad Thru Notary Public Underwriters . !svr>,, Owner Builder Affidavit **ALL INFORMATION HIGHLIGHTED IN r jd City of Atlantic Beach Building Department GRAY IS REQUIRED. 'M , 800 Seminole Rd, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT#: I. FLORIDA STATUTES;CHAPTER 489, FLORIDA STATUTES, PART 1 "CONSTRUCTION CONTRACTING" REQUIRES OWNER/BUILDER TO ACKNOWLEDGE THE LAW: DISCLOSURE STATEMENT FOR SECTION 489.103(7), FLORIDA STATUTES: STATE LAW REQUIRES CONSTRUCTION TO BE DONE BY LICENSED CONTRACTORS. YOU HAVE APPLIED FOR A PERMIT UNDER AN EXEMPTION TO THAT LAW. THE EXEMPTION ALLOWS YOU,AS THE OWNER OF YOUR PROPERTY,TO ACT AS YOUR OWN CONTRACTOR EVEN THOUGH YOU DO NOT HAVE A LICENSE. YOU MUST SUPERVISE THE CONSTRUCTION YOURSELF. YOU MAY BUILD OR IMPROVE A ONE OR TWO FAMILY RESIDENCE OR A FARM OUTBUILDING. YOU MAY ALSO BUILD OR IMPROVE A COMMERCIAL BUILDING AT A COST OF$25,000.00 OR LESS. THE BUILDING MUST BE FOR YOUR USE AND OCCUPANCY. IT MAY NOT BE BUILT FOR SALE OR LEASE. IF YOU SELL OR LEASE A BUILDING YOU HAVE BUILT YOURSELF WITHIN ONE YEAR AFTER THE CONSTRUCTION IS COMPLETE,THE LAW WILL PRESUME THAT YOU BUILT IT FOR SALE OR LEASE, WHICH IS IN VIOLATION OF THIS EXEMPTION. YOU MAY NOT HIRE AN UNLICENSED PERSON AS YOUR CONTRACTOR. YOUR CONSTRUCTION MUST BE DONE ACCORDING TO THE BUILDING CODES AND ZONING REGULATIONS. IT IS YOUR RESPONSIBILITY TO MAKE SURE THAT PEOPLE EMPLOYED BY YOU HAVE LICENSES REQUIRED BY STATE LAW AND BY COUNTY OR MUNICIPAL LICENSING ORDINANCES. II. INJURY LIABILITY; SINCE OWNERS MAY BE LIABLE FOR INJURIES TO WORKERS THEY HIRE,THE BUILDING DEPARTMENT SUGGESTS WORKER'S COMPENSATION INSURANCE BE PURCHASED. . III. IRS WITHHOLDING;OWNERS HIRING WORKERS BECOME EMPLOYERS AND SHOULD ALSO OBSERVE IRS WITHHOLDING TAX AND/OR FORM 1099 REQUIREMENTS ON THE WORKERS THEY EMPLOY ON THEIR IMPROVEMENT TRADES. IV. PENALTY; UNLICENSED CONTRACTORS CANNOT BE EMPLOYED UNDER ANY CIRCUMSTANCES. OWNERS BEING SUBJECT TO $5,000 PENALTY UNDER FLORIDA STATUTE NO. 455-228(1). AN "OCCUPATIONAL LICENSE" IS NOT ADEQUATE. THE OWNER SHOULD PHYSICALLY SEE THE COUNTY"CERTIFICATE OF COMPETENCY"OR THE FLORIDA"CONTRACTORS CERTIFICATE"TO ASCERTAIN IF A PERSON IS A LICENSED CONTRACTOR. CONTACT THE BUILDING DEPARTMENT(904- 247-5826 OR BUILDING-DEPT@COAB.US) IF IN DOUBT. V. ACKNOWLEDGEMENT; I HEREBY ACKNOWLEDGE THAT I HAVE READ THE ABOVE DISCLOSURE STATEMENT AND THAT I COMPLY WITH ALL THE REQUIREMENTS FOR THE ISSUANCE OF AN OWNER-BUILDER PERMIT. Job Address: , a.. • f•. '., /A A I . .. a Owner Name: )1160-K „�-'rr/ LT10,c- ,0k f^1 C. ( 1 -71 -n j Phone Number: ?() .?.-'90 P '1 9 (� Mailing Address:a( I"cr) seT/ 1 ci S"'t City: /-�-f'"/o'.7 1 C €a�tra�te: rL Zip: 'C�,; 3 Yt Notarized Signature of Owner f • The foregoing ins ument was acknowledged before me thday g k ii• ,20ZJin the State of Florida, County of Signature of Notary Publi - SA) [ ] Personally Known OR [ ] Produced Identification Type of Identification: i --� (-- :P ° TONI G'NDLESPERGER Updated 10/24/18 MY COMMISSION#GG 353178 „.. ; 1,,`,' EXPIRES:October 6,2023 ''.,F!,::':':':”' Flooded Thru Notary Public Underwriters . ... .,„:„.., .,,„ 'S � td ' ''' ,\` CITY OF ATLANTIC BEACH S 800 SEMINOLE ROAD \j+� ,•. ATLANTIC BEACH,FL 32233 \ \ (904)247-5800 �JJ319f' SURVEY AGREEMENT NOTICE All new projects creating more than 250 Square Feet of impervious surface or requiring on-site storm water retention, including swimming pools,will require pre-construction and post-construction topographic surveys, as required by COAB, Section 24-66 and described in Bulletin 2-18, Surveys. The surveys must be new original documents, from a licensed surveyor, signed, sealed, and dated. Other small projects, such as fences and construction less than 250 SF, will not require a new topographical survey, but a current original-size survey with all relevant details is still needed. These surveys,when included as part of a building permit application, must be complete, up-to-date, and original size and scale, as produced by the surveyor. Copies.of old surveys lacking details or copies not of original size cannot be accepted. Building permit applications with unacceptable surveys cannot be reviewed and the application will be returned to the applicant. Thank you for your cooperation in this matter. AGREEMENT I have read and understand the Notice above and affirm that the outdated survey I am submitting is still accurate and complete, and all structures and impervious surfaces on the property are shown on the survey. I further understand that, if the survey is found to be inaccurate or incomplete, a $50.00 Plan Resubmittal Fee will be charged; or if the permit has been issued, a Stop Work Order will be posted with the associated $110.00 Fee. JOB ADDRESS i I�HI AA .� s �� , ' 1_Ltd FL -3, .z3_2 OWNER or CONTRACTOR ' ,'nt) /) l 4 Y K & ct (s 10 \ c AleCi -nY11 S ., < Signature d 2v---e-- Date 9 - ?-"(2 OD, 1 . • MAP SHOWING SURVEY OF LOT 540, SECT I ON NC. 3 SAL TA IR AS RECORDED IN PLAT BOCK 1O ,* PAGE 16 OF ThE CURRENT PUBLIC RECORDS OF DUVAL (XU\ITY, FLCR IDA. --C1L-- Z.07- .5-Z9 LOT 5213 Ze527— 52.7 , Fric5.A"Le jjo.r 50.0 47 F ND 1/2" LP __ 20. PINE--"" ' i NZi) 6,' levoc).G> I N 03 _ " C15 7,/ " L.07-- 541 0 2-_5 7-0/11 Y 0 L77 53e 0 r,' E icr A me A P'7: N 0 0 \) 0 A A---7---.? -0'.zerz i zed. ) FE EhEY 1 4, N. if , \i•t' 'tvE5oV N 4). 9 cY ...k1.47s AI IN , t''':'. c4 ' : : .4N.- '.-• S) . k.i • .e . ., . ' %41 rND.Y;I.P. 50 - PM>.Vi. I.F' N.11/ : . -, - ' :' . 1 •V 8 3' :. . . ,:'. . 0 50.0 1 , I 10 PO/A/SETT/4 Srice&-r . Ni. ._._..4) •,e/i,t, i Niarg--- 4•SSLIKete-r-> ELEV 42 c7' c:71.,,i I 4.11/4-.1t> IKI LikIE VVI 71-1 •Scutr ti coFP-e. -TV L-11-JE. I HEREBY CERTIFY THAT THE PROPERTY SEDAN EERECN IS IN FLOOD ZCNE "C" AS S ON TEE FLOOD HAZARD BOLI\DPRY MAP FCR THE C I TY CF ATLANTIC BEACH, FLCR IDA. I HEREBY CERT I FY TO GARY OR I DER AND KE I TH R I ECHMAM THAT I HAVE SURVEYED TEE LANDS AS SEC:M.N IN THE ABOVE CAPT I CN AND THAT TH I S MAP I S A TRUE AND CORRECT. REPRE SENTAT I ON OF THAT SURVEY AND THAT THE SURVEY REPRESENTED HERECN IvEET S TEE MINI /1,M STANDARD REQUIREMENTS A COPTED BY THE FLCR IDA SOCIETY OF PROFE 551 CNAL LAND SURVEYORS AND TEE FLCR IDA LAND T I TLE AS SOC I AT ION C . riii/A.4. :MAY .3 0, / 85/ SIGNED:MAY if. l'?03 SCALE:I" ‘ \atibi FOLIKIT:Wric>K1: ..J(•-i1 E. I 4.,=', ilr)e, --, FLoRiDA REGISTERED LAND SURVEYOR- No.3295 k - BOATAR I CI-1T LAND SL,RVEYCRS , INC:. . 4 -1 -ini pgrvkitam anon cl JIT in it . lark cr-Nv I, I F RFACI-i. FL CR IDA 241 -8 50 �s r 4 - 7/i PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH, FLORIDA (*REQUIRED) /4-1.-/q � a'27 *Project Address:t' D. 01' 1 Self la I_-z 3 Permit#: *Owner/Project Name: �Y4 �[ Y < a 1�c CTI o < ck �rl r1 I As required by Florida Statute 553.842 and Florida Administrative Code Rule 9B-72, please provide the information and product approval number(s)for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product approval may be obtained at:www.floridabuilding.org. r� S.E- s . * O\C/, eel Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# A.EXTERIOR DOORS 1.Swinging 2.Sliding 3.Sectional 4.Garage Roll-Up 5.Automatic 6. Other B.WINDOWS 1.Single hung 2. Horizontal slider 3. Casement 4. Double hung 5. Fixed 6.Awning 7. Pass-through 8. Projected 9. Mullion 10.Wind breaker 11. Dual action 12.Other Page 1 of 4 Updated 10/17/18 Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# E.SHUTTERS 1.Accordion 2. Bahama 3.Storm panels 4. Colonial 5. Roll-up 6. Equipment 7. Other F.STRUCTURAL COMPONENTS 1.Wood connector/anchor 2.Truss plates 3. Engineered lumber 4. Railing 5. Coolers-freezers 6. Concrete admixtures 7. Material 8. Insulation forms 9. Plastics 10. Deck-roof 11.Wall 12.Sheds 13.Other G.SKYLIGHTS 1.Skylight 2. Other H. NEW EXTERIOR ENVELOPE PRODUCTS 1. 2. Page 3 of 4 Updated 10/17/18 i , Mark and Gloria McGinnis 282 Poinsettia St Atlantic Beach, FL 32233 904-708-1370 Wood Shed 8'x12' height max 8' Material List(Additional information) 1 or 3 lbs of each nail/screw type: #8x1-1/4" lath screws for floor joists 10"x3-1/2" Power Pro exterior flat head premium wood screws to fasten treated sheathing and framing 6-8d 2" galvanized spiral shank exterior siding nails T1-11 10"x2-1/2 T25 Power Pro for framing Structural Components Simpson Strongtie Mitek USP JA1 TZ 16 gauge 1 1/2"x 11/2"x 1 1/"framing angle FL17244 Simpson Strongtie Mitek USP A3 TZ 2"x 1 1/2" x 2 3/4" framing angle FL17244 Simpson Strongtie medium twist strap MTS 12—FL 10456.25 Simpson Strongtie LUS ZMAK face-mount joist hanger FL10531.16 Roofing GAF Timberline HDZ Asphalt shingles—wind coverage 150 mph FL10124-R30 GAF QuickStart Peel and Stick Roofing Starter Shingle Roll Grip Rite 1 1/1"Roofing Nails 0 Titan Block-Foundation blocks 10- 8 in. x 8 in. x 16 in. Concrete Block (meets ASTM C90 standard) Hurricane ties ShelterLogic 4 of 30in. steel HD Auger Anchors 10075 holding capacity 6000 lbs Door Everbilt 12 in HD Tee Hinge Everbilt HD Door Knob Mark and Gloria McGinnis 282 Poinsettia St Atlantic Beach, FL 32233 904-708-1370 Wood Shed 8'x12' height max 8' Page 4 Joist hangers used on both ends of each inner joists --LUS ZMAX galvanized face-mount joist hanger for 2x4 lumber --Each outer corner Mitek Simpson Strong Tie angle A3 T2 FL17244 AZ070220A Page 5 --Using 23/32 treated 4'x8' plywood --using 3.5' #10 power pro stainless steel screws every 16" to 20" Page 7 -- 2x4 lumber for the double headers Page 8 --Door will be on the back wall Page 9 --Beams every 20" OC Page 15 --rafters every 20" OC attached with simpson strong tie MTS 12" 16-gauge galvanized medium twist straps HowToSpecialist.com Materials • A- 3 pieces of 4x4 lumber- 144" long SKIDS • B -2 pieces of 2x6 lumber- 144" long, 10 pieces - 93" long FRAME • C - 3 pieces of 3/4"plywood-48"x96" long FLOOR • D - 1 piece of 2x4 lumber- 144" long, 2 pieces - 34 1/2" long, 8 pieces - 80" long, 2 pieces - 76" long, 2 pieces of 2x6 lumber- 75" long FRONT WALL • E -2 pieces of 2x4 lumber- 144" long, 9 pieces - 113 5/8" long,4 pieces - 19 3/4" long, 8 pieces -22 1/2" long BACK WALL • F-2 pieces of 2x4 lumber- 89" long, 1 piece - 89" long, 5 pieces - 80" long 2xSIDE WALL • G- 9 pieces of TI-11 siding-48"x86" long, 1 piece -48"x7" long SIDING • H-2 pieces of 2x4 lumber- 88 3/8" long, 2 pieces - 23 1/2" long, 2 pieces - 15" long, 2 pieces - 7 1/2" long SUPPORTS • H- 5 pieces of 5/8" T1-11 siding-48"x37 1/4" long. 2 pieces -48"x19 3/4 long SIDING • I - 7 pieces of 2x4 lumber- 112" long RAFTERS • J- 2 pieces of 3/4" plwyood-48"x96" long, 2 pieces -48"x48" long, 1 piece - 16"x48" long, 1 piece- 16"x96" long ROOF • K- 2 pieces of 2x6 lumber- 112 3/4" long, 2 pieces of 1x6 lumber- 145 1/4" long TRIMS • L - 150 sq ft of tar paper, 150 sq ft of asphalt shingles ROOFING • M- 3 pieces of 2x4 lumber- 79" long JAMBS • N - 2 pieces of T1-11 siding- 36"x76 3/4" long, 2 pieces of 2x4 lumber- 69 3/4" long, 2 pieces - 36" long, 1 piece -29" long 2xDOOR • 3 pieces of 4x4 lumber- 12' • 2 pieces of 2x6 lumber- 12' • 10 pieces of 2x6 lumber- 8' • 2 pieces of 2x6 lumber- 10' • 4 pieces of 2x4 lumber- 12' • 40 pieces of 2x4 lumber- 8' • 16 pieces of 2x4 lumber- 10' • 7 pieces of 3/4" plywood-48"x96" • 12 pieces of T1-11 5/8" siding-4'x8' • 2 pieces of 1x6 lumber- 14' • hinges & latch • 150 sq ft of tar paper, 150 sq ft of asphalt shingles • rafter ties • wood filler, wood glue, stain/paint • shed hinges • 2 1/2" screws, 3 1/2" screws, 1 5/8" screws • 6d nails • structural nails for ties • wood filler,wood glue, stain/paint Page 2 of 28 HowToSpecialist.com This step by step woodworking project is about 8x12 lean to shed plans. If you need more storage space in the backyard, but you are short on space, building this lean to shed will make the most of it. Check out PART 2 and PART 3 of the project, so you learn how to build the roof and the double doors. Read the local codes before starting the project, as in some cases a permit might be required. We recommend you to invest in the best materials you could afford. Therefore, you should buy weather-resistant lumber, such as pine or cedar. Always take accurate measurements before adjusting the size of the components at the proper size. Drill pilot holes trough the components before inserting the wood screws,to prevent the wood from splitting. 8x12 Lean to Shed Plans 3 I L IK H -,,, . 410P;iii P. .. ".-----...... 444' 4.-411111 , ---7—...11> II 10P4111 M � , 0 I N a --- lo.--'-- F D B A Building a 8x12 lean to shed Page 1 of 28 HowToSpecialist.com Tools • Safety gloves, glasses • Miter saw,jigsaw • Chalk line, tape measure, spirit level, carpentry pencil • Drill machinery and drill bits Time • One Day Page 3 of 28 HowToSpecialist.com Building a 8x12 lean to shed 144" 41 44%,•411444 i/2" 74" 41/2" -. 41/2" <NN, 4 1/2" X41/2" 93„ 14 1/2" 14 1/2" 13 3/4" Building-the-floor-of-the-shed Build the floor for the garden shed from 2x4 or 2x6 lumber. Cut the joists at 144" and at 93" using a sharp saw. Drill pilot holes through the rim joists and insert 3 1/2" screws into the perpendicular components. Make sure the edges are flush. Measure the diagonals and make adjustments till they are equal. Page 4 of 28 HowToSpecialist.com f • 144" 42 3/4" 42 3/4" Attaching-the-skids Attach 4x4 skids to the floor frame, so you can lift the shed from the ground and protect it from moisture. Drill pilot holes through the joists and insert 4 1/2" screws into the skids. Alternatively, you can use rafter ties to secure the skids to the floor frame. Page 5 of 28 HowToSpecialist.com " 96"....,,,,,„>, 48“ Fitting-the-floor-sheets Attach the 3/4"plywood sheets to the floor frame. Align the edges flush, drill pilot holes and insert 1 5/8" screws, every 8" along the joists. Leave no gaps between the sheets for a professional result. Page 6 of 28 HowToSpecialist.com 144" 3t12" 81/ " 81/ " 3 112" 19 3/4" 119 3/4" • 81`� 7611 1--34 1/2"—I 1-34 1/2"--I Front wall- Frame Build the frame for the front wall from 2x4 lumber. Drill pilot holes through the plates and insert 3 1/2" screws into the studs. In addition, you need to use 2x6 lumber for the double header. Fit 1/2"plywood between the double headers and insert 2 1/2" screws to lock them together tightly. Page 7 of 28 HowToSpecialist.com 144" 3 2" 3 2" 30 5/8" 6.9,/ 9 3/4'122 1/2 22 1/2"122 1/2'1122 1/249 3/4 Back wall-Frame Continue the project by assembling the back wall frame. Cut all the components to the right dimensions, according to the information from the diagram. Drill pilot holes through the plates and insert 3 1/2" screws into the studs. Place the studs every 24" on center. Fit the middle supports between the studs,by toenailing them. Page 8 of 28 HowToSpecialist.com 89" Off [1814"i[2212"JL221/2"--111814"] I l1 Side walls- Frames Build the side wall frames using the same techniques described above. Drill pilot holes through the plates and insert 3 1/2" screws into the studs. Page 9 of 28 HowToSpecialist.com , k 4 i ` y ' y ,,„,,,,, „, . cialisi ,,, NV -1 - 4''''' 1 , , 1 40 I 1 I /� 4„ • ..„..„,....„,„ I r� I AN r// Building the shed Fit the wall frames to the floor of the shed. Align the edges flush, drill pilot holes and insert 3 1/2" screws into the floor. In addition, lock the adjacent walls together by using screws, Use a spirit level to plumb the walls and a carpentry square to make sure the corners are right angled. Page 10 of 28 HowToSpecialist.com linffilliMIMMIIIMIMMrilill 1 is1 86" 4.0000 - i i 48"- �.. .. Back wall-Siding Fit the T1-11 siding panels to the back wall of the shed. Align the edges with attention and insert 6-8d nails, every 8", along the framing. Leave no gaps between the sheets for a professional result. Page 11 of 28 HowToSpecialist.com I _4811 4811 86" Side walls-Siding Cut the panels to the right size, as shown in the diagram. Fit the T1-11 siding panels to the sides of the lean to shed. Align the edges with attention and insert 6-8d nails into the framing, every 8" along the structure. Page 12 of 28 HowToSpecialist.com 4811 4811 meminimilsoi Lilsi 86" 79" -12". Front wall-Siding Cut the panels for the front wall from T1-11 siding at the right dimensions. Attach the panels to the front wall using 6-8d nails. Page 13 of 28 HowToSpecialist.com How to build a lean to shed roof E\iJ „ :416112" `3 )8" 3 ,,, 5/8c 1 gill X131 " 5,, Building the rafters The first step of the project is to build the rafters from 2x4 lumber. Mark the cut lines on the 2x4 beams and then get the job done with a circular saw. Smooth the edges with sandpaper. Page 14 of 28 HowToSpecialist.com 1 3/'" OP. - 2 1/ 2 1/2„ 4N r 22 1/2" ,00100100:1 ,, ' 2 44 21 3/4" \l',:.',,,t, , , N ://, Pr, ,i f, 1 , 7/ </7,17,/, 4 mai Fitting the rafters Fit the rafters to the top of the shed and place them every 24" on center. Use rafter ties to lock the rafters to the top plates. Page 15 of 28 HowToSpecialist.com 1 2" 1 12" 3 ." 3 4" 1 ir21' 31," 1 11 2" .. I Jr" 1 z,' 37 1/4" 48" To back wall - Siding Use T1-11 siding for the top side of the back wall. Mark the cut lines on the siding and get the job done with a jigsaw. Smooth the edges with sandpaper. Fit the siding panels to the back of the wall and lock them into place with 6-8d nails. Leave no gaps between the panels for a professional result. Page 16 of 28 HowToSpecialist.com 20 degrees rf l 1 88 3/8" l ® Hower `l , 1 ,, . ... . .. , . __ . , ,4 I 1 , 1; 1 ,.., . i v ,. _ , .,,, Side wall top plates Use 2x4 for the side supports of the lean to roof ends. Make a cut to one end of the supports and then lock them into place with 2 1/2" screws. Page 17 of 28 HowToSpecialist.com 70 degrees — 19 1/2"- -19 1/2"- F-171/4"- -171/4"- a st 7 W21 . Lean to sides supports Use 2x4 lumber for the lean to sides of the roof. Drill pilot holes at both ends of the supports and lock them into place with 2 1/2" screws. Page 18 of 28 HowToSpecialist.com oecialisl 19 3/4" l 1/4" --48"- - -4$ -- Lean to side ends Cut the panels for the lean to roof ends and then attach them into place tightly. Align the edges flush and insert 6-8d nails. Page 19 of 28 HowToSpecialist.com 96" l i 48"n 16" allaimialliallb " a sI -1 , __, . . , . 48" L , . . .........„,,......,MP 98n 48„ I\ Fitting the roofing sheets Cut the roof sheets from 3/4" plywood and then attach them to the top of the shed. Align the edges flush, drill pilot holes and insert 1 5/8" screws to secure them into place, every 8" along the rafters. Page 20 of 28 HowToSpecialist.com 145 1/4" 1 w 112 3/4" .. Y 1---in --, 1.48.1/4" - - , Fitting the trims Use 2x6 lumber for the side overhangs and 1x6 lumber for the front and back roof trims. Align the components with attention and secure the trims into place with 2" brad nails. Page 21 of 28 HowToSpecialist.com Asphalt shingles Tar paper • r' .`_ l - ✓ ✓ ' �, � � yam- '. JJJ d" , ' 711 \kik . 4 Fitting the roofing You could fit asphalt shingles to protect the shed, as it is a straight forward solution. Therefore, install roofing felt over the roofing sheets, making sure the strips overlap at least 2". Secure the tar paper to the plywood sheets with roofing staples. Fit the side drip edges over the roofing felt, while the bottom drip edges should be fit under. Place a starting course at the bottom of the roof, before installing the asphalt shingles. Always read the manufacturing instructions before starting the installation, as there are several aspects that differ. Smart Tip: The first course should star with a 3 tab shingle, the second course with a 2 1/2 tab , the third course with a 2 tab, the forth course with a 1 1/2 tab,the fifth course with a 1 tab,the sixth course with a 1/2 tab. Repeat the process from the beginning, starting with the seventh course. Don't forget that the shingles should overhang from the drip edge about a 1/4". In addition, secure the asphalt shingles to the roof decking with tacks. Page 22 of 28 HowToSpecialist.com Building double doors for the 8x12 lean to shed lit 79• I i � l I I � _ Fitting the jambs First of all, you need to attach the 2x4 jambs around the door opening. Align the edges flush, drill pilot holes and insert 2 1/2" screws. Page 23 of 28 HowToSpecialist.com F36" . .1/4n .. 33 1/4' iai pc 76 3/4"69 3/4" 14%\ Building the doors Use T1-11 siding for the door panels and use 2x4 lumber for the trims. Align everything with attention and then use 1 5/8" screws to lock the siding to the trims. Install the diagonal braces to the double doors. Page 24 of 28 HowToSpecialist.com • Hinges - alisi • Latch Fitting the doors Fit the double doors to the opening and align the edges flush. Use hinges to secure the doors into place tightly. Moreover, you need to install a latch and a handle. Page 25 of 28 HowToSpecialist.com I 8x12 Lean to Shed Plans-Open doors Last but not least, you need to take care of the finishing touches. Fill the holes with wood putty and smooth the surface with 120-220 grit sandpaper. Page 26 of 28 HowToSpecialist.com mmemommirmilmomm or I's , # NIP 1# 1 \ / \ / DIY 8x12 Lean to Shed Apply a few coats of paint or stain over the components, so you enhance the look of the shed and to make them weather resistant. You can also add 1x4 trims to the corners and to the four sides of the shed, if you want to add more appeal to it. Page 27 of 28 HowToSpecialist.com 004101111111111111111111111111...min 1111111 - 8x12 Lean to Shed Plans- Back view Page 28 of 28